GU_NONE_T0965-LP-109-1010_Rev1_Sht1 THRU 158_N_A_GU-KA-437-04 TANK LEVEL INDICATING TLI SYSTEM TYPE NO. 36000.pdf
PDF 3 MB Posted
- Attached to
- FY27 NOAA Ship Gordon Gunter Drydock REFERENCES
- Solicitation number
- 1305M226Q0144REF
About this file
This is a technical specification document for a Tank Level Indicating (TLI) System Type No. 36000, serving as a reference document for the FY27 NOAA Ship Gordon Gunter drydock solicitation (1305M226Q0144REF). The document comprises 158 sheets of technical drawings, schematics, and specifications that establish the performance and design requirements for the tank level indicating system to be used on the NOAA vessel.
The TLI System Type No. 36000 is a specialized marine instrumentation system designed for monitoring and indicating fuel, water, or other liquid tank levels aboard the research vessel. The reference document provides detailed technical specifications, dimensional drawings, electrical schematics, installation requirements, and performance standards necessary for contractors bidding on the drydock work to understand the existing system or to supply replacement/upgraded components. As a reference document tied to the special notice for the Gordon Gunter drydock project, this specification serves to inform potential contractors of the technical baseline and equipment standards they must work within or maintain during the vessel's maintenance and renovation activities. Contractors responding to the drydock solicitation would need to review these technical specifications to ensure compliance with existing vessel systems or to propose compatible alternatives, depending on the scope of work required during the drydock period.
View the file
Other files
Show 40 more
Latest 50 of 134 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T0965-LP-109-1010
TECHNICAL MANUAL
INSTALLATION, OPERATION, AND MAINTENANCE
INSTRUCTIONS
FOR
TANK L E V E L INDICATING
(TLI> SYSTEM
TYPE NO. 36000
^ NAVSEA 0965-LP-109-1010
W/CHQ 1
TECHNICAL MANUAL
INSTALLATION, OPERATION, AND MAINTENANCE
INSTRUCTIONS
for
TANK LEVEL INDICATING
(TLI) SYSTEM
TYPE No. 36000
Th is publications Is required for official use or for administrative or operational purposes. Distribution Is limited to U.S. Government agencies only. Other requests for this document must be referred to: Commandlng'Offlcer, Naval Ship Weapon Systems Engineering Station, Code 5700, Port Hueneme, CA 93043."
PUBLISHED BY DIRECTION OF
COMMANDER, NAVAL SEA SYSTEMS COMMAND
29Moy1974
NAVSHIPS 0965-109-1010
LIST OF EFFECTIVE PAGES
Total number of pages In this manual is 182 consisting of the following:
Page # Change Number No.
Tttle 1 A . ! 1 I . 7 1 I I 0 iU 1 Iv to Ix 0 1-0 to 1-2 0 1-3 1 1-4 to 1-12 0 1-13 1 1-14 to 1-15 0 1-16 1 1- 17 to 1-20 0 2- 1 to 2-8 0 3- 1 to 3-14 0 3-15 Blank 1 3-17 to 3-26 0 3-27 Blank 1 3- 29 to 3-36 0 4- 1 to 4-5 0 4- 6 Blank 0 5- 1 to 5-19 0 5- 20 Blank 0 6- 1 to 6-8 0 7- 1 to 7-24 0 7-25 Blank 7-27 Blank 7-29 Blank 7-31 Blank 7-33 Blank 7-35 Blank 7-37 Blank 7-39 Blank 7-41 Blank 7-43 Blank 7-45 Blank 7-47 to 51 0 7- 52 Blank 0 8- 1 to 8-19 0 8-20 Blank 0 I - l to 1-4 0
#Zero in this column Indicates an original page.
RECORD OF CHANGES
CHANGE
NO.
DATE TITLE OR BRIEF
DESCRIPTION
ENTERED BY
15 October 1975 Additional Contracts and Updated Engineering Drawings
GEMS DeLaval
CHANGE 1
APPROVAL AND PROCUREMENT RECORD PAGE
APPROVAL DATA FOR:
TITLE OF MANUAL:
APPROVAL AUTHORITY:
NAVSHIPS 0965-109-1010
Installation, Operation and Maintenance Instructions for Tank Level Indicating (TLI) System, Type No. 36000
NAVSEC (HyattBvllle) Itr. 6178B. 02/WHN; 9650-5; Ser 929;
29 May 1974 Contract N66314-73-D-2878
CONTRACT QUANTITY QUANTITY
NUMBER SHIPS APPLICABLE MANUALS EQUIPMENT BUILDING YARD
665-166 New Construction 51 1 SET Marinette Marine N00406-74-C-0944 DLG-25 40 1 SET Puget Sound NSY 1021-866-R DLG-11 50 1 SET Bath Iron N00406-74-C-0940 DD-885 2 1 SET Puget Sound NSY N66314-74-C-2341 SSN-592 8 1 SET N.S. Oakland N66314-74-C-2469 DLG-15 14 1 SET Mare Island N00406-74-C-0907 DEG-1 40 1 SET Puget Sound NSY N66314-74-C-2118 SSBN-618, 610 24 1 SET N.S. Oakland N001C2-74-C-0057 SSN-673 6 1 SET Portsmouth NSY N00102-74-C-0057 SSN-646 6 1 SET Portsmouth NSY 2528 DD-818 10 1 SET Home Bros.
383 LST-1179 10 1 SET Home Bros.
1735 LPH-9 10 1 SET Holmes Bros.
E87194E1B WAGB-10 33 1 SET Lockheed 1-40-3143 31 1 SET General Dynamics R00238 AOR-7 6 1 SET National Steel J-1031-719 SSN-667 10 1 SET Electric Boat G025gi-E-IB2 WAGB-11 33 1 SET Lockheed K216-704 SSN-671 10 1 SET Electric Boat N00189-74-C-0346 CVA-67 2 1 SET Norfolk NSY N00102-74-C-0467 See Below 3 58 SETS Portsmouth NSY
SSN-575 SSBN-628
SSN-584 SSN-670
SSGN-587 SSN-664
SSN-585 SSN-675
SSN-588 SSN-674
SSN-591 SSN-676
SSN-590 SSN-666
SSN-596 SSN-653
SSN-613 SSN-650
SSN-612 SSN-637
SSN-606 SSN-647
SSN-605 SSN-639
SSN-614 SSN-648
SSN-615 SSN-579
SSN-594 SSN-583
SSN-598 SSN-621
SSN-599 SSN-682
SSBN-601 SSN-660
SSBN-618 SSN-672
SSBN-611 SSN-678
S8BN-620 SSN-661
SSBN-622 SSN-638
SSBN-625 SSN-663
SSBN-626 SSN-677
SSBN-627 SSN-679
SSBN-62g SSN-662
SSBN-632 SSN-665
SSBN-633 SSN-649
SSBN-630 SSN-680
u ORIGINAL
NAVSHIPS 0065-109-1010
APPROVAL AND PROCUREMENT RECORD PAGE (Cont)
CONTRACT QUANTITY QUANTITY
NUMBER SHIPS APPLICABLE MANUAI£ EQUIPMENT BUILDING YARD
N00406-74-C-1710 AS-32 40 1 SET Puget Sound NSY N00406-75-C-1564 SS-590 1 SET Puget Sound NSY N00123-75-M-Y052 AOR-1 2 1 SET Long Beach NSY N00406-75-M-2177 SS-590 9 1 SET Puget Sound NSY K311-701 10 1 SET Electric Boat K216-704 10 1 SET Electric Boat N00406-75-C-2702 SS-672 9 1 SET Puget Sound NSY N00406-75-C-1593 See Below 9 11 SETS Puget Sound NSY
LPH-11 CVA-66
LPH-7 LPH-10
LPH-9 CVA-60
CVA-59 CVA-61
CVA-41 CVA-67
CVA-62
370-106-A FFG-7 14 1 SET Bath Iron Works N00140-75-C-0276 See Below 189 37 SETS N.R.P.O. Phila
DE-1052 DE-1059
DE-1063 DE-1064
DE-1068 DE-1072
DE-1075 DE-1051
DE-1041 DE-1038
DEG-5 DEG-3
DLG-14 DLG-22
DLG-18 DD-937
DD-940 DD-941
DD-943 DD-933
DDG-2 DDG-3
DDG-4 DDG-8
DDG-10 DDG-13
DDG-19 DDG-22
DDG-23 DDG-24
DLG-26 DLG-30
DLG-34 DLG-31
DDG-32 DD-931
DD-946
Mare Island N00221-75-M-7424 SS-613 4 1 SET Mare Island
REMARKS:
CERTIFICATION: It is hereby certified that NAVSHIPS 0965-109-1010 to be provided under contract or purchase order N66314-73-D-2878 has been approved by the approval data shown below.
DATE: 29 May 1974
MANUFACTURER'S SIGNATURE
DELAVAL Gems Sensors Division Farmington, Connecticut 06032
VALIDATION PERFORMANCE
TlUe of Publication: Installation, Operation and Maintenance Instructions for Tank Level bidicating (TLI) System, Type No. 36000
Contractor: DELAVAL Gems Sensors Division Spring Lane Farmington, Connecticut 06032
Contract No. N66314-73-D-2878
Chapter Section Paragraph Date Validation Completed
Check here if not validated
IthruS 10 May 74
Name & Authority of Validating Officer:
Signature of Validating Officer: Chief Engineer yv—•
J iv ORIGINAL
SAFETY SUMMARY
The following are general safety precautions that are not related to any specific procedures and therefore do not appear elsewhere in this publication. These are recommended precautions that personnel must understand and apply during many phases of operation and maintenance.
KEEP AWAY FROM LIVE CIRCUITS: Operating personnel must at all times observe all safety regulations. Do not replace components or make adjustments inside the equipment wUh the high voltage supply turned on. Under certain conditions, dangerous potentials may exist when the power control is in the off position, due to charges retained by capacitors. To avoid casualties, always remove power and discharge and ground a circuit before touching it.
DO NOT SERVICE OR ADJUST ALONE; Under no circumstances should any person reach into or enter the enclosure for the purpose of serviclng'or adjusting the equipment except in the presence of someone who is capable of rendering aid.
RESUSCITATION: Personnel working with or near high voltages should be familiar with modern methods of resuscitation. Such information may be obtained from the Bureau of Medicine and Surgery.
The following WARNINGS appear in the text in this volume and are repeated here for emphasis.
WARNING WARNING
Observe caution during the performance of the following procedures. 115-volt, 60-HZ power is connected to components of the TLI system even though power is turned off at the components.
(Page 4-1)
WARNING
Use solvent in a well ventilated area. Avoid breathing the solvent fumes. Keep the sol vent away from flame.
(Page 4-3}
When performing adiustmetot and align ment procedures in fluid tanks that con tain or have contained flammable or explosive fluids, ground the tank and observe all precautions for a hazardous area.
(Page 6-1)
WARNING
WARNING
Observe all precautions for working in a hazardous area when removing a trans mitter fluid tank containing flammable or explosive fluids.
(Page 6-6)
Observe caution during the performance of the following procedures. 115-volt, 60-Hz power Is connected to components of the TLI system even though power is turned off at the component.
(Page 4-3)
WARNING
When cleaning a transmitter, level link, or cable assembly in a fluid tank that has contained a flammable or explosive fluid, ground the tank and observe all precau tions for a hazardous area.
(Page 4-3)
WARNING
Flush and dry any tank that contains or contained flammable fluids and make certain that all flammable materials are removed from the area in which an in stallation procedure is to be accomplished.
(Page 8-8)
WARNING
Observe caution when handling power leads at all times. Death or serious injury can result from contact with these voltages.
(Page 8-16)
WARNING
ORIGINAL
Observe caution during the performance of the following step when handling live elec trical leads. Death or serious injury can result from contact with these voltages.
(Page 8-18)
TABLE OF CONTENTS
Chapter
1. GENERAL INFORMATION
1-1 Introduction 1-4 Purpose of Equipment 1-7 Physical Description 1-8 General 1-9 Fluid Level Detection
Devices 1-19 Receiver Devices 1-30 Remote Alarm and Fluid Level
Indicating Devices 1-37 Installation Accessories . . .
1-38 Technical Characteristics . .
1-40 Equipment Complements • . .
1-41 General 1-42 Transmitter Part No.
Identification 1-43 Level Link Part No.
Identification 1-44 Cable Assemlily Part No.
Identification 1-45 Receiver Modules Part No.
Identification 1-47 Receiver Panels 1-48 Equipment Required, But Not Supplied 1-49 Field Changes and
Factory Changes . . .
OPERATION
Page
1-1 1-1 1-1 1-1 1-1
1-1 1-3
1-10 1-10 1-13 1-14 1-14
. . 1-14
1-14
1-19
1-19 1-19
1-20
1-20
2-5 2-6 2-7
2-12 2-21 2-22
3-1 3-4
3-13
3-14 3-15 3-21
3-34
3-39
3-40 3-41
3-43
3-50 S-Sl
General Operating Controls and
Indicators Operating Procedures . . .
Turn-On Procedure Fluid Level Monitoring
Procedure Alarm Monitoring Procedure Turn-Off Procedure Emergency Sfaut-Down
Procedure
General Overall Block Diagram
Discussion 3-1 Detailed Block Diagram
Discussion 3-2 General 3-2 Receiver Module Installation Receiver Panel Installation .
3-2 3-5/ 3-6
Multi-Alarm Indication Receiver Module 3-10
Power Distribution Diagram Discussion 3-10
General Page 3-10 Receiver Module Power
Distribution 3-10 Receiver Panel Power
Distribution 3-10 Detailed Circuit DlBCussloo . . 3-17 General 3-17
Chapter Page
3-52 Transmitters 3-17 3-58 Level Links 3-18 3-62 Receiver Modules 3-18 3-70 Receiver Panels 3-23/
3-24 3-92 Remote Alarm and
Indicator Devices 3-35
General 4 Scheduled Maintenance Index . 4 Inspection Procedures General ^ . . A Exterior Inspectloi 4 Interior Inspection 4 Cleaning 4-3 Out-of-Tank Components . . . 4-3 In-Tank Cdmponents . . . . 4-3 Lubrication 4-3 Scheduled Performance Tests General Monthly Performance Test .
Overhaul Cycle Performance
Test
SCHEDULED MAINTENANCE
4-1 4-3 4-6 4-7 4-8 4-9 4-10 4-11 4-12 4-13 4-15 4-16 4-17 4-18
4-3 4-3 4-3
4-5/ 4-6
TROUBLESHOOTING 5-1
5-1
2-1 5-3 Troubleshooting Indexes . . . 5-1 2-1 5-5 Troubleshooting Diagrams . . 5-2
5-7 Maintenance Dependency 2-1 5-2 2-6 5-8 5-2
5-10 5-11 5-5
2-6 5-12 5-5 2-7 5-13 5-5
5-14 Troubleshooting Using Mainte nance Dependency Charts . . 5-5
2-8 5-19 Detail Troubleshooting 5-6
3-1 5-20 5-6 3-1 5-21 Transmitters and Level Links. 5-6
5-22 Standard Electronic Elements . 5-6
6-1 6-1
C(»tRECTIVE MAINTENANCE. . .
6-1 General Section L ADJUSTMENTS AND
ALIGNMENTS 6-1
6-3 General 6-1 6-5 Meter Calibrations 6-1 6-8 Zero Adjustment .6-1 6-12 Full-scale Deflection -
Adjustment 6-2 6-15 Fluid Level Calibration . . . 6-2 6-16 Dry Tank Calibration . . . . 6-3 6-17 Llquld-ln-Tank Calibration . . 6-4 6-18 Interface Calibration 6-4 6-19 Alarm Adjustments 6-4 6-20 General 6-4 6-21 Receiver Module Adjustment . 6-4 6-22 Receiver Panel Adjustment . . 6-4 vi ORIGINAL
NAVSHIPS 0065-109-1010
TABLE OF CONTENTS (Cont)
Chapter Page
Section n. REPAIR . 6-5 6-23 General Maintenance Proce dures and Precautions . . . 6-5 6-̂ 5 Transmitter Repair 6-5 6-26 General 6-5 6-27 Removal 6-5 6-28 Replacement 6-6 6-31 Level Link Repair 6-6 6-32 General 6-6 6-38 J-BOK and Alarm Box Repair . 6-7 6-40 Receiver Module Repair . . . 6-7 6-42 Receiver Panel Repair . . . 6-8 6-44 General Parts Rejdacement
Techniques 6-8 6-45 General 6-8 6-46 Printed Circuit Board Resistor and Capacitor Replacement . 6-8 6-47 Semiconductor Diode
Replacement 6-8 6- 48 Transistor and Microcircult
Replacement 6-8
PARTS LIST 7-1
7- 1 General 7-1 7-3 Parts List 7-1 7-10 List of Manufacturers . . . . 7-1 7-12 List of Attaching Hardware . . 7-1 7- 14 List of Common Item
Descriptions 7-1
INSTALLATION 8-1
8- 1 General 8-1 8-3 Site Information 8-1 8-4 Site Selection 8-1 8-5 Transmitters 8-1 8-11 Receiver Modules 8-3 8-12 Receiver Panels 8-3 8-13 Level Links 8-3 8-16 Site Preparation 8-8 8-17 Reference Publication . . . . 8-8
Chapter Page
8-19 Tools and Materials Required for tistallation . . 8-8
8-21 Unpacking and Repacking . . . 8-8 8-24 Preparation of Foundations . . 8-9 8-26 Input Requirements 8-9 8-28 Installation Procedures . . . . 8-9 8-29 General 8-9 8-30 Mgsinting'Î ocedures S-sO 8-31 ' Bracket Mgunted Transmltters-
~Weld Mounting 8-9 8-32 Bracket Mounted Transmitters-
Sounding Tube Mounting . . 8-11 8-33 Bracket Mounted Transmitters-
Ladder Mounting 8-12 8-34 Flange Mounted Transmitters . 8-12 8-35 Stuffing Tube Penetration
Assembly 8-12 8-36 Level Links, Complete
Sensor Mounting 8-13 8-37 Level Links, Transmitter
Combination Mounting . . . 8-13 8-38 Level Links, biterface
Indication Mounting . . . . 8-14 8-39 Receiver Modules, Panel
Mounting 8-14 8-40 Receiver Modules, Bulkhead
Mounting 8-14 8-41 Receiver Panels 8-14 8-42 Alarm Box 8-14 8-43 Alarm Bell 8-15 8-44 Electrical Connections . . . . 8-15 8-45 Installation Calibrations . . . 8-16 8-47 Installation Adjustments . . . 8-16 8-49 Installation Checkout 8-16 8-50 General 8-16 8-51 Phase 1 - Installation Inspection and Pre-Energlzing Procedures 8-16
8-52 Phase 2 - Initial Turn-On and Preliminary Test 8-18
8-53 Phase 3 - Bustallation Verifica tion Test 8-18
ORIGINAL
LIST OF ILLUSTRATIONS
Number Title Page Number TlUe Page
1-1 Equipment and Accessories 1-0 1-2 Transmitter Types 1-2 1-3 Level Link Types 1-2 1-4 Typical Station Assembly 1-3 1-5 Transmitter Cables Installation Data
(Sheet 1 of 2) 1-4 (Sheet 2 of 2) 1-5
1-6 Receiver Module Types 1-6 1-7 Receiver Panel Types 1-7 1-8 Typical Receiver Panel, Interior View. .1-8 1-9 Typical Control Module 1-9 1-10 Remote Alarm and Fluid Level
Indicating Devices 1-11 1-11 Installation Accessories (Sheet 1 of 2). .1-12
Installation Accessories (Sheet 2 of 2). .1-13 1- 12 Typical Complete Part Number
Designations 1-18
2- 1 Typical Receiver Module Operating Controls and Indicators 2-4
2-2 Multi-Alarm Indication Receiver Module Operating Controls and Indicators 2-4
2-3 Typical Receiver Panel Operating Controls and Indicators 2-5
2- 4 Alarm Box Operating Controls and Indicators 2-6
3- 1 Tank Level Indicating (TLI) System, Block Diagram 3-1
3-2 Receiver Module Installation, Servicing Block Diagram 3-3
3-3 Receiver Panel Installation, Servicing Block Diagram 3-7
3-4 Multi-Alarm Indication Receiver Module Installation, Servicing Block Diagram .3-11
3-5 Receiver Module, Power Distribution Diagram 3-13
3-6 Receiver Panel, Power Distribution Diagram 3-15
3-7 Typical Transmitter, Cross-Section View 3-18
3-8 Two-Transmitter Installation, Schematic Diagram 3-18
3-9 Operational Sequence of Transmitter Tap Switches 3-19
3-10 Transfer Switch Operation in Overlapped Transmitters 3-19
3-11 Typical Level Link Arrangement . . . .3-20 3-12 Level Link, Schematic Diagram . . . .3-20 3-13 No-Alarm, Dual-Alarm, Hi-Lo Alarm and Secondary Receiver Modules, Schematic Diagram 3-21
3-14 Multi-Alarm Indication Receiver Module, Schematic Diagram 3-25
3-15 Receiver Panels, Schematic Diagram . .3-27 3-16 Power Supply and Master Alarm
Module PSl (PS2), Schematic Diagram 3-29 3-17 Flasher and Full-Wave Bridge Rectifier
Module FL1(FL2), Schematic Diagram 3-31 3-18 Receiver Panel Control Modules, Schematic Diagram 3-33 3-19 Alarm J-Box, Schematic Diagram • . .3-36
3- 20 Portable Secondary Meter Connection Box, Schematic Diagram 3-36
4- 1 Receiver Module Side Panel Controls . .4-4
5- 1 Transmitter Cable Wiring Diagram . . .5-3 5-2 Transmitter to Receiver, J-Box and Alarm Modules Wiring Diagram. . 5-4 5-3 Receiver Module Power Distribution, Maintenance Dependency C h a r t . . . . 5-7 5-4 Receiver Panel Power Distribution, Maintenance Dependency C h a r t . . . . 5-9 5-5 Receiver Module, Maintenance
Dependency Chart 5-11 5-6 Multi-Alarm Indicator Receiver Module, Maintenance Dependency Chart (Sheet 1 of 2) 5-13 (Sheet 2 of 2) 5-15
5- 7 Receiver Panel, Maintenance Dependency Chart(Sheet 1 of 2) . . . 5 - 1 7
(Sheet 2 of 2) . . . 5-19
6- 1 Edgeview Meter, Zero Adjustment Location 6-2
6-2 Edgeview Meter, Face Detail 6-2 6-3 4-1/2-Inch Square Meter, Face Detail . .6-2 6-4 Removing Station Assembly From
Mounting Brackets 6-7 6-5 Cutting Level Link Interconnecting
Cables 6-7 6- 6 Station Assembly Top Identification . . . 6-7
7- 1 Transmitters, Types XM-36485, XM-36480, XM-36460, XM-36465, XM-36470 and XM-36475 7-2
7-2 Mounting Bracket Assemblies, Part No. 36407, 36413, 36409, 32445, 31795 and 32579 7-4
7-3 Transmitter Cable Assemblies, Part No. 36880-( ), 36885-( ), 36890-( ), 37890-( ) and 36889-( ). . . 7-6
7-4 Level-Link Assemblies, Part No. 35801, 35802, 35803 and 35804 7-8
7-5 Tank Penetration Assembly, Part No. 36424 7-8
7-6 Welding Fixtures, Part No. 36452, 36453 and 36454 7-8
7-7 Portable Secondary Meter, Part No. 37495 7-8
7-7A Alarm Relay Circuit Board, Part No. 38060, Parts Location . . .7-10
7-8 Receiver Modules, Part No. RE-38330, RE-31340, RE-31360 and RE-31370 (Typical) 7-25
7-9 Receiver Modules, Part No. RE-37030, RE-31320, RE-31326 and RE-31330 (Typical) 7-27
7-10 Multl-Alarm Receiver Module, Part No. RE-32915 7-29
7-11 Receiver Panels, Part No. 37060, 37050 and 37040 (Typical) (Sheet 1 of 2) 7-31 (Sheet 2 of 2) 7-33 vlii ORIGINAL
LIST OF ILLUSTRATIONS (Cont)
Number Title Page Number TlUe Page
7-12 Receiver Panels, Part No. 38360, 38350 and 38340 (Typical) (Sheet 1 of 2) 7-35 (Sheet 2 of 2) 7-37
7-13 Control Modules, Part No. 38139, 38129, 38149, 38119, 38159 and 38100 (Typical) 7-39
7-14 Flasher and FuU-Wave Rectifier Module, Part No. 38105 7-41
7-15 Power Supply and Master Alarm Module, Part No. 38005 7-43
7-16 Alarm J-Box, Part No. 35549 . . . . 7-45 7- 17 Secondary Meter Connection Box, Part No. 37450 7-47 8- 1 Typical Transmitter Installation
(Sheet 1 of 2) 8-2 (Sheet 2 of 2) 8-3
8-2 Receiver Module Mounting, Outline and Dimensions (Sheet 1 of 2) 8-4 (Sheet 2 of 2) 8-5
8-3 Receiver Panel, Outline and Dimensions 8-6
8-4 Level Links, Outline and Dimensions . 8-7 8-5 Level Link Installation with Inclined
Station Assembly 8-7 8-6 Non-Linear Tank Contoured with
Level Link 8-8 8-7 Typical Welding Fixture 8-9 8-8 Positioning Welding Fixtures for
Installation 8-10 8-9 Locating Mounted Bracket Assemblies for Multiple-Transmitter Installations 8-11 8-10 Standplpe Mounting Installation
Part No. 33000 8-13 8-11 Alarm Bell, Outline and Dimensions in accordance with MIL-A-15303 . . . 8-15 8-12 Lead Reversal for Interface
Indication 8-16 8-13 Connecting Secondary Receiver
Modules 8-16 8-14 Installation Standards Summary
Sheet 8-17
LIST OF TABLES
Number Title Page
1-1 Reference Data 1-13 1-2 Equipment, Accessories and Documents Supplied 1-15 1-3 Receiver Panel Control Modules 1-20 1- 4 Equipment Required,But Not Supplied 1-20
2- 1 Operating Controls and Indicators 2-1
4- 1 Index of Scheduled Maintenance 4-2
5- 1 Troubleshooting Index 5-1 5-2 Fuse Index 5-1 5-3 Relay Index 5-2 5- 4 Indicator Lamp Index 5-2
6- 1 Sample Listing of Tank Soundings 6-3
7- 1 Parts List 7-3 7-2 List of Manufacturers 7-49 7-3 List of Attaching Hardware 7-50 7- 4 List of Common Kerns 7-51
8- 1 Transmitter Welding Fixture Applications 8-9 r r rANK_Tqp J ' ° ' | _ .
T O P "
TRANSMITTER
(FLANGE
MOUNTED)
TRANSFER
TRANSMITTER
(SOUNDING TUSE
MOUNTED)
TANK
SOUNDING
^ T U B E
BOTTOMING
TRANSMITTER
(BRACKET
MOUNTED)
FLUID TANK 4
ALARM B E L L
/PRIMARY
/ RECEIVER
MODULE
r '^ MULTI-ALARM
3 RECEIVER ^
MODULE
•ooooo e « • _i
TANK
PENETRATION
STUFFING TUBE
T 1 lIBIi l_ I
^ SECONDARY
B CONNECTION
BOX
P̂ORTABLE
SECONDARY
METER
Figure 1-1. Equipment and Accessories
CHAPTER 1
GENERAL INFORMATION
1-1. INTRODUCTION.
1-2. This technical manual contains installation, operation, and maintenance instructions for Tank Level Indicating (TLI) System, and related equipment Type No. 36000, manufactured by DELAVAL Gems Sensors Division, Farmington, Connecticut 06032.
Individual TLI systems are comprised of different equipment and accessories in accordance with the requirements of individual Installations. Equipment and accessories used in typical system arrangements are shown in figure 1-1. This manual describes the operation, theory of operation, preventive and cor rective maintenance procedures, troubleshooting, installation, and physical and technical characteris tics for the components that can be selected to form any given TLI system. An illustrated parts list is also provided for the identification and location of the repair parts for the equipment and accessories in cluded in a system.
1-3. Chapter 1 describes the purpose of TLI systems and includes physical descriptions and a list of tech nical characteristics. Equipment, accessories, and documents that can be supplied as part of a system are listed. In addition, those equipment and acces sory items that are required to install, operate, and maintain the system, but which are not supplied, are listed.
1-4. PURPOSE OF EQUIPMENT.
1-5. TLI systems provide a means of determining the level of fluids stored in shipboard fluid tanks.
The level of the fluid is indicated on meters contained in system components distributed throughout the ship.
Meter deflection is continuous, in incremental steps, or in a combination of both.
1-6. Electrical signals representing the fluid level that has been detected can also be examined to deter mine whether the fluid level lies within predeter mined values in the associated tanks. If the fluid level falls below or rises above these predetermined values, audible, visual and/or electrical signal alarm Indications can be provided at TLI system components and/or at other shipboard locations.
1-7. PHYSICAL DESCRIPTION.
1-8. GENERAL. TLI system components can be divided into four general categories: fluid level de tection devices, receiver devices, remote alarm and fluid level indicating devices', and installation acces sories. Descriptions of the types of equipment avail able within each category follow.
1-9. FLUID LEVEL DETECTION DEVICES. Fluid level detection devices are installed in the fluid tanks of the ship, serving as transducers that convert the fluid level in the tank to an electrical signal. Trans ducers of two types are available, transmitters (which provide a continuous tank level signal) and level links (which provide tank level signals repre senting specific increments of fluid level). Cable assemblies associated with the fluid level detection devices connect transmitters or level links to other transmitters or level links, to ship's wiring, to re ceivers, and/or to each other.
1-10. Transmitters. One or more of six basic trans mitter types may be used singularly or in combination with level links to form a fluid level detection device for a fluid tank. The number of transmitters and the type used are determined by the height of the fluid tank and by the nature of the fluid level indication that is required. Each of the six transmitter types, (figure 1-2) consists of a network of voltage divider resistors a!nd magnetic reed switches which are con tained in silicon rubber potted in a mylar tube that is surrounded by a neoprene tube and all mounted in a stainless steel tube. Electrical leads connecting to the resistors and magnetic reed switches are brought to electrical connectors located at the top, bottom, or both ends of the transmitter.
1-11. A cylindrical float assembly located on the stainless steel tube is free to move up and down the tube within limits established by retaining rings or pairs of brackets that are integral with the transmit ters. The bracket pairs or circular flanges on the tube are used as mounting surfaces for the installation of transmitters in the fluid tank.
1-12. Transmitter types XM-36470 and XM-36475 are similar in construction and application. Each of these types is constructed for a flange-mounted ap plication. In flange-mounted installations, the float assembly on the transmitter is free to rise to the top of the tank and thereby can be used to indicate the level of fluids that rise as high as the top of the tank.
Transmitter type XM-36470 is a bottomed transmit ter; that is the bottom surface of the transmitter is sealed making it applicable to a single-transmitter installation. Transmitter type XM-36475 is a trans fer transmitter; that is, the bottom of the unit is not sealed, but is terminated in an electrical connector for connection to a cable assembly that runs to another transmitter in a multi-transmitter installation.
1-13. The other four transmitter types shown in fig ure 1-2 incorporate a pair of brackets and are in tended for bracket mounting. Transmitter types
ORIGINAL 1-1
ELECTRICAL CONNECTOR
BRACKET
SHOCK TUBE
FLOAT
• B R A C K E T -
E L E C T R I C A L CONNECTOR-
TYPE X M - 3 6 4 6 0 TYPE X M - 3 6 4 6 S
E L E C T R I C A L CONNECTOR
FLANGE
RETAINING RING
SHOCK TUBE
FLOAT
ELECTRICAL CONNECTOR
T Y P E X M - 3 6 4 7 0 TYPE XM-3647B
BRACKET
SHOCK TUBE
M F L O A T - M
I i r ^ BRACKET—___1iJ
T ~ - E L E C T R I C A L CONNECTOR^ 7
T Y P E X M - 3 6 4 8 0 T Y P E X M - 3 6 4 B S
Figure 1-2. Transmitter TVpes
XM-36460 and XM-36480 are bottomed transmitters and, therefore, are used in single-transmitter in stallations. Since Type XM-36460 has its electrical connector at the top of the transmitter, the float is unable to rise to the full height of the unit. This transmitter type is therefore used in those single transmitter installations in which it is required to indicate fluid levels at the bottom of the tank, but not at the very top of the tank. The point of maximum level indication lies below the top of the fluid tank.
Type XM-36480 is an inverted version of the XM- 36460; that is, it is designed for Installation with its electrical connector at the bottom of the unit. The type XM-36480 is therefore used in single-transmit ter installation in which fluid levels at the top of the taiik can be indicated, but fluid levels can be indicated only to a minimum point that lies above the bottom of the tank.
1-14. Transmitter types XM-36465 and XM-36485 are used in multiple-transmitter installations. Both types contain additional internal magnetic reed switches that enable the use of these transmitters with other transmitters in the same fluid tank installation. These switches provide a transfer function when the fluid level rises or falls within an area of transmitter over lap. The type XM-36465 transmitter has electrical connectors at both ends, permitting its use as an in termediate transmitter between upper and lower trans mitters. The type XM-36485 is an inverted transfer transmitter and therefore serves as the top transmit ter in a multiple-transmitter installation.
1-15. Level Links. One or more of four basic level link types can be used alone or in combination with transmitters to form a fluid level detection device.
Hie type of level link used in any installation is deter mined by the type of level-link transmitter combina tion that is to be instaUed. Type LL-35801 is used for installations in which a level link by itself forms the fluid level detection device. (See figure 1-3.)
Type LL-35802 is used for installations in which the level link is located at the bottom of a fluid tank and is combined with one or more transmitters installed above the level link. Type LL-35803 is used for in stallations in which the level link is located at the top of a fluid tank and is combined with one or more transmitters below the level link. Type LL-35804 is used for installations in which a level link serves as an intermediate fluid detection device with one or more transmitters located above and below the level link.
PENETRATION PENETRATION
CABLE
30 INCH
MIN
CONNECTOR
AND
ADAPTOR
(TYPICAL)
10 INCH
MIN
k 4>
7 INCH
MIN
i A
V y y ?
k i l l
NAME PLATE
ITTPICAL I
10 INCH
MIN
LEVEL-L INK
TYPE 1 5 ( 0 1
LEVEL-LINK
TYPE 3SS02
L E V E L - L I N K
TYPE 3SS03
LE VEL-L INK
TYPE 3 S 8 0 4
Figure 1-3. Level Link Types
1-2 ORIGINAL
1-16. Each level link is comprised of a number of cable-connected station assemblies. The number of station assemblies in a level link is determined by the height for which incremental fluid level indication is required. Individual station assemblies include a magnet-equipped float that rides up and down on a stem. The stem houses a resistor, magnetic reed switches, and semiconductor diode. A mounting bracket on the stem permits individual installation of ea6h station assembly.
1-17. Level link type LL-35801 is terminated at one end by a penetration cable that passes through the fluid tank bulkhead and at the other end of the bottom most station assembly by a molded diode assembly.
(See figure 1-4.) Level link type LL-35802 substi tutes a connector and adaptor in place of the penetra tion cable of type L L - 35801 to permit electrical con nection to a transmitter. Level link type LL-35803 has the penetration cable at the same location as type LL-35801, but substitutes electrical connector for the molded diode assembly to permit connection to a lower transmitter. Level link type LL-35804 is ter minated at both ends by electrical connectors to per mit connection to transmitters above and below the level link.
COTTER
PIN
^ MOLDED "T"-
TOP OF
STATION
MOUNTING
BRACKET
"^'^^ LOCKING
BAR
^ LOCKING ^ LOCKING
COTTER
PIN
LEVEL
STATION
Figure 1-4. Typical Station Assembly
1-18. Cable Assemblies. Five types of cable as-semblies are used in fluid detection devices to pro vide electrical connections between transmitters and/ or level links inside of a fluid tank and to ship's wir ing, J-boxes, or receivers outside of the fluid tank.
(See figure 1-5.) Connections between two transmit ters or a transmitter and a level link are described as jumper connections; connections between a trans mitter or a level link and a component outside of the fluid tank are described as penetration connections (the connection provides penetration of the fluid tank bulkhead). Cable assembly type 36880 is a penetra tion cable assembly. It is terminated at one end by an electrical connector whereas the other end has loose electrical leads that connect to terminals on a
J-box or receiver terminal board. Cable assembly type 36885 is terminated at both ends by electrical connectors to permit its use as a jumper connection between two transmitters. Cable assembly type 36890 is a T-shaped cable assembly that is terminated at two ends by electrical connectors and has loose leads at the third. Type 36890 serves as a combined jum per and penetration connecting device that is normal ly used with inverted transmitters. Cable assembly type 36889 is similar to cable assembly type 36885 described above, but uses a different electrical con nector suited to high-pressure applications. Cable assembly type 37890 is similar to cable assembly type 36890; however, the loose ends of the type 36890 are terminated on the type 37890 by an electrical con nector suited to high-pressure applications.
1-19. RECEIVER DEVICES. Receiver devices, mounted on ship's bulkheads and in equipment panels aboard ship, convert the electrical signals generated by the fluid level detection devices to deflections on meters usually calibrated in gallons. Some receivers also examine electrical level signals to develop an alarm condition if the fluid level in the tank rises above or falls below preselected heights in the fluid tank. Alarm generating receivers actuate relay con tacts to indicate the existence of an alarm condition, and in some cases, provide visual and audible indica tions of an alarm condition.
1-20. Two categories of receiver devices are avail able for use with a TLI system: one category includes receiver modules, the other receiver panels. Each receiver module performs level indication, alarm generation, and/or alarm indication functions for one fluid tank. Each receiver panel provides the three functions for from 4 to 15 fluid tanks.
1-21. Receiver Modules. Receiver modules are rectangular box-like units that are rack-mounted for installation in an equipment panel or a bulkhead. (The mounting racks for receiver modules are described in paragraph l-37g.) Three groups of receiver modules (figure 1-6) are available for use in a TLI system: one group indicates fluid level on 4-1/2-inch square-shaped meters; a second group that Indicates fluid level on 5-inch eclgeview meters; and a third group consisting of only one receiver module type which has no fluid level meter. The third group, a multi-alarm indication receiver module is described under the heading of remote alarm and fluid level in dicating devices. (Refer to paragraph 1-31.)
1-22. Within each of the first two groups of receiver modules, four variations are used to determine the functions performed. This receiver module, like all receiver modules that perform the level indication function by processing signals from the fluid level detection devices, is called a primary receiver. No-alarm receiver modules with Parts No. 31326 and 31340 for 4-1/2-inch square and edgeview meters, respectively, provide a level indication function only.
Diuil-alarm receiver modules with Parts No. 31320 and 3i?<{0 add either one or two alarm generating capabilities to the level indication function, the quan tity determined by the number of alarms (single or dual) specified during procurement. Alarms are generated at dual-alarm receiver modules when fluid
CHANGE 1 1-3
PENETRATION CABLE ASSEMBLY , TYPE 36800
PART NO.36880-A
USE: CONNECTS TRANSMITTER TO J-BOX OR RECEIVER
It
K E Y : A = L E N G T H IN F E E T + 3 - 0 FEET
RED
WHITE
BLACK
SCHEMATIC
JUMPER CABLE ASSEMBLY, TYPE 36800
PART NO. 36885-A
USE: CONNECTS TRANSMITTER TO TRANSMITTER
OR TO TANK PENETRATION. PART NO. 30150
If
KEY: A=LENGTH IN FEET+3-0 FEET
RED
BLACK
WHITE
SCHEMATIC
T CABLE ASSEMBLY , TYPE 36800
PART NO. 36890 /A -FX-J /B -FX-J /C -FX-J
USE: CONNECTS INVERTED TRANSFER TOP TRANSMITTER
TYPE XM-36485 TO OTHER TRANSMITTER AND TO RECEIVER
WHITEn RED rBLACK
7~-
C-FX-J
:^x3 ^
•A-FX-
KEY:
•B-FX-J-
A = UPPER TRANSMITTER
8 = LOWER TRANSMITTER
C= BULKHEAD FITTING
F=4-CONDUCTOR CABLE
J = JUNCTION
X = LENGTH IN FEET+3-0 FEET
SCHEMATIC
Figure 1-5. Transmitter Cables Installation Data (Sheet 1 of 2)
1-4 ORIGINAL
JUMPER CABLE ASSEMBLY , TYPE 36889
PART NO. 36889-A
USE-. CONNECT TRANSMITTER TO TRANSMITTER
IN HIGH-PRESSURE APPLICATIONS.
A
RED
In
KEY: A=LENGTH IN FEET+3-0 FEET SCHEMATIC
T CABLE ASSEMBLY , TYPE 37890
PART NO. 3 7 8 9 0 / A - F X - J / B - T X - J / C - T X - J
USE: CONNECTS INVERTER TO TRANSFER TOP
TRANSMITTER TYPE XM-36485 TO OTHER TRANSMITTER
AND TO RECEIVER IN HIGH-PRESSURE APPLICATIONS
WHITE
KEY:A=UPPER TRANSMITTER
8= LOWER TRANSMITTER
C = BULKHEAD FITTING
F =4-C0NDUCT0R CABLE
J = JUNCTION
T =3-CONDUCTOR CABLE
X= LENGTH IN FEET+3-0 FEET
SCHEMATIC
TYPICAL CONNECTOR PARTS LOCATION
ADAPTER
CONNECTOR
LOCKWIRE
CABLE
0-RlNG
SETSCREW
(3)
Figure 1-5. Transmitter Cables Installation Data (Sheet 2 of 2)
ORIGINAL 1-5
4-1/2 INCH SQUARE METER
NO-ALARM
PART NO RE-31326
DUAL-ALARM
PART NO. RE-31320
HI-LO
LEVEL ALARM
PART NO RE-37030
SECONDARY
PART NO. RE-31330
5 INCH EDGEVIEW METER
NO-ALARM
PART NO. RE-31350
DUAL-ALARM
PART NO. RE-31360
HI-LO
LEVEL ALARM
PART N0.RE-3a330
SECONDARY
PART NO. RE-31370
e •
TYPICAL RIGHT SIDE VIEW TYPICAL BACK VIEW
Figure 1-6. Receiver Module Types levels exceed selected high or low values or when either condition is detected in same tank. These alarms take the form of relay contact closures that are associated with a high-level alarm or low-level alarm, as applicable. HI-LO alarm receiver modules with Parts No. 37030 and 38330 add one or two alarm indication capabilities to the level indication and alarm generating function, the quantity determined during procurement. Alarm indications are pro duced in the form of lamp illuminations that identify the type of alarm (adjustable high-level or low-level).
A relay contact closure developed by HI-LO alarm receiver modules indicates the presence of an alarm, only, without identifying whether the alarm is pro duced by a high-level or low-level condition. This closure is used to sound an alarm horn or bell. Sec ondary receiver modules, Parts No. 31330 and 31370 are slave units which produce fluid level meter deflections only. Secondary receiver modules con tain no electronic circuits other than fluid level meters and so are unable to process signals coming from fluid level detection devices. They, therefore, are slaved to receiver modules of other types.
1-23. Receiver modules have operating controls and indicators mounted on the front panel. On receiver modvdes with alarm functions, adjustment controls are accessible on the right side panel. Electrical connections are made to connectors on the rear bottom of the units. All electrical parts are accessible for maintenance purposes when the right side panel is re moved.
1-24. Receiver Panels. Receiver panels are box-like units that are mounted to bulkheads using flanged sec tions welded to the top and bottom of the box. (See figure 1-7.) As in the case of receiver modules, re ceiver panels are available with either 4-1/2-inch square fluid level meters or edgeview meters. Indi vidual receiver panel types vary, not only in the types of meter used to indicate fluid level, but in the number of fluid tanks for which fluid-level indications and alarm functions can be provided. Receiver panels with Parts No. 37040 and 38340 process signals for four to seven fluid tanks, each; receiver panels with Parts No. 37050 and 38350 process signals for 8 to 11 fluid tanks, each; and receiver panels with Parts No.
37060 and 38360 process signals for 12 to 15 fluid tanks.
1-25. Fluid level meters for each fluid tank being indicated are located on a hinged front cover. When any given receiver panel is associated with a number of fluid tanks that is less than its capacity, a blank plate is installed in place of meters that are not re quired. Two indicating lamps are mounted above each meter to indicate the detection of alarm condi tions, when applicable. Operating controls that are common to all fluid tank circuits on the receiver panel are located at the lower right portion of the cover.
1-26. When captive screws on the hinged cover are released, the cover can be opened to make the elec trical parts of the receiver panel accessible for maintenance purposes. These parts are mounted on the cover, the interior rear wall of the receiver panel box, and on printed circuit board modules housed in one or two circuit board racks. (See figure 1-8.)
One printed circuit board rack is supplied when eight or less fluid tanks are serviced, two for twelve or more. One printed circuit board control module is provided for each active meter on the receiver panel.
The functions performed by different control modules are determined by the requirements of the fluid tank being processed. (Refer to paragraph 1-28.) In addi tion to the control modules provided for each meter, each receiver panel also contains one or two power supply and master alarm modules and may contain one or two flasher and full-wave bridge rectifier modules. (Flasher and full-wave rectifier modules are optional equipment.) Two modules of the types indicated are used on those receiver panels that are associated with twelve or more fluid tanks.
1-27. Electrical connections to the receiver panel are made to terminal board strips mounted on the rear interior wall of the box. One terminal board strip is associated with each fluid tank, one with in put power, one with each group of eight control
1-6 ORIGINAL
4-1 /2 INCH SQUARE METER
4 TO 7 METERS
PART NO. 37040
4 TO 7 METERS
PART NO. 38340
Ez:
8 TO II METERS
PART NO. 37050
12 TO 15 METERS
PART NO. 37060
BOOS
SOOi
SB5S
5 INCH EDGEVIEW METER
8 TO 11 METERS
PART NO. 38350
12 TO 15 METERS
PART NO. 38360
v.!
Figure 1-7. Receiver Panel Types modules, and one with a FLOAT SIMULATOR poten tiometer mounted on the rear interior wall.
1-28. Control modules, power supply and master alarm modules, and flasher and full-wave bridge rectifier modules are fiberglass epoxy printed cir cuit boards on which electrical parts are mounted.
(See figure 1-9.) A calibration pushbutton switch and calibration and alarm threshold screwdriver ad just potentiometers mounted on the board are acces sible from the front edge of the board with the mod-tale in its rack. Six types of control modules are available for use with each fluid tank serviced by the receiver panel. The type of control module installed at the applicable location in the printed circuit board rack determines the functions performed for the fluid tank.
1-29. A high and low .ilarni control modulo providos level indication. hit;h alarm condition detection, und low alarm condition detection. A hi^h and a two hit:h alarms control module provide level indication and high alarm condition detection. A low and .) two low alarms control module provide level indication and low alarm condition detection. A level indication module provides level indication, only. Relays on the alarm control modules provide the contact closures necessary to indicate that an alarm condition has lieen detected. On the two hit;li and two low alarm control modules, two relays provide a means of respiMidiii!:
to two individual hi^h or low alarm conditions. The inclusion of two relays differs from the situation in the hich alarm control module and low alarm control module, each of which has only one relay. The hich and low alarm control module
ORIGINAL 1-7
CI
O O O
TB-17 TB- I
il
I - - 0 TB-18
TB-19
TB-20
TB-2
TB-3
TB-4
TB-5
TB-6
CAUTION
TB-7
CAUTION
TB-16
TB-8
TB-9
TB-IO
TB-II
TB-12
TB-13
TB-14
TB-15
(Si cm-t
CM-T
If
T V
If
3L
(§1
7=
Figure 1-8. Typical Receiver Panel, Interior View
1-8 ORIGINAL
ALARM CIRCUIT
NO.2(B) ALARM
THRESHOLD ADJUST
POTENTIOMETER
ALARM CIRCUIT
NO. 1(A) ALARM
THRESHOLD ADUST
POTENTIOMETER
CALIBRATE
SWITCH
CALIBRATE
POTENTIOMETER
Figure 1-9. Topical Control Module
ORIGINAL 1-9
contains two relays, one for each type of alarm condition.
1-30. REMOTE ALARM AND FLUID L E V E L INDI
CATING DEVICES. Remote alarm and fluid level in dicating devices are devices that contain alarm bells or lamps to indicate the detection of a high or low fluid level alarm by a receiver module or receiver panel, and in one case, a portable fluid level meter that serves as a portable secondary receiver. De scriptions of the remote alarm and flidd level indi cating devices that are available for use with a three-wire tank level indicating system are contained in the following paragraphs.
1-31. Multi-Alarm Indication Receiver Module. The multi-alarm indication receiver module (figure 1-10) is contained in the same modular box-like case as the receiver modules described in paragraph 1-21.
However, the multi-alarm indication receiver module contains no fluid level meter. It contalns-circuits that permit it to respond to the detection of a high fluid level or low fluid level alarm by up to six alarm circuits in receiver modules. Response to alarm detection is provided by the lighting of a front panel lamp associated with the alarm circuits and the sound ing of a sonalert audible alarm in the multi-alarm in dication receiver module. A toggle switch for the silencing of the sonalert alarm and a fuse are also contained on the front panel. Electrical connection to the unit is made at the bottom of the box enclosure and includes power input, signal input and remote audible output.
1-32. The alarm lamps on the front panel of the multi-alarm indication receiver module are parts of lamp-switch assemblies that have a press-to-test feature. When the lens of the lamp is pressed to wards the panel, the switch portion of the assembly is actuated and applies a test signal to the lamp. A properly operating lamp lights while the lens is held depressed.
1-33. Alarm J-Box. The alarm J-box (figure 1-10) is an electrical connection box that contains audible (sonalert) and visual (lamp) alarm indicators and a toggle switch that silences the audible alarm. Elec trical connection to the alarm J-box is made to an internal terminal board strip via two stuffing tubes mounted on the circumference of the J-box.
1-34. Alarm Bells. Two alarm bells (figure 1-10) are available for use with a TLI system, a 3-inch and an 8-inch bell. These bells are standard Navy alarm bells that are installed on a bulkhead using mounting holes in a metal strip at the rear of the alarm bells.
1-35. Portable Secondary Meter and Connection Box Combination. Portable secondary meter and connec tion box combinations are available for the observa tion of fluid level indications at remote locations aboard ship. Secondary connection boxes (figure 1-
10) used in these combinations are distributed at appropriate locations. The secondary connection boxes have a cover that incorporates a magnet. This maKnet actuates a reed switch within the secondary connection box when the cover is closed. With the reed switch actuated, a resistor is switched in place to act as a dummy load for a meter circuit in a prima ry receiver module or receiver panel. When the cover is opened, the resistor is removed from the circuit and a portable secondary meter is connected to an electrical connector in the secondary J-box to form a series circuit with the primary meter circuit.
1-36. The portable secondary meter is a box-like structure with a carrying strap. When the front cover of the luiit is opened, access is provided to a fluid-level meter and storage space containing a cable that connects to a secondary connection box. When the electrical connector on the cable is plugged into the mating secondary J-box electrical connector, the meter deflects to indicate the same readout as the primary receiver module or receiver panel meter to which the secondary connection box is wired.
1-37. INSTALLATION ACCESSORIES. A variety of installation accessories are available to aid and ac complish the mounting and wiring of the components of a TLI system. (See figure 1-11.) Installation accessories are as follows:
a. Weld-Mounting Bracket Assemblies. Three types of mounting bracket assemblies are available for the weld-mounting of bracket-mounted transmit ters. Mounting bracket assemblies, Part No. 36407 and 36413, are stainless steel and carbon steel mounting brackets, respectively, that are welded to the bulkhead of the fluid tank in which a transmitter is to be installed. These mounting bracket assem blies are drilled through to accommodate mounting bolts, that are secured to the brackets on transmit ters with lockwashers, flat washers and nuts. Mount ing bracket assembly, Part No. 36409 is similar to Parts No. 36407 and 36413, but has tapped holes.
The tapped holes permit mounting bolts to be secured in the bracket for those installations in which there is not enough room for nuts, flat washers and lock-washers on the outside of the bracket.
b. Sounding Tube Mounting Bracket Assembly.
Sounding tube mounting bracket assemblies, Part No.
31795 and 32445, are used to mount bracket-mounted transmitters to 1-1/2-inch and 2-inch sounding tubes in fluid tanks, respectively. Both sounding tube mounting bracket assembly types consist of an angle bracket, a U-bolt sized to accommodate the associ ated sounding tube diameter, and holes that line up with the holes on transmitter brackets.
c. Ladder Mounting Bracket Assembly. Lad der mounting bracket assembly, Part No. 32579 is similar to the sounding tube mounting bracket assem bly described above. However, a C-bolt is used in place of the U-bolts to permit the ladder mounting bracket assembly to be secured to a fluid tank ladder.
d. Standpipe Mounting. Standpipe mounting, Part No. 33000, is comprised of a 5-inch flange con nected to a 5-inch pipe section. The unit is welded in a hole drilled in the top of a fluid tank to provide a supporting surface for flange- mounted transmitters.
e. Stuffing Tube Penetration Assembly. Stuff ing tube penetration assembly, Part No. 36424, 1-10 ORIGINAL
8 - INCH ALARM BELL
PART NO . 3 5 7 4 5 0
JL ^
ALARM BOX
PART NO.35549
" 0 • 0 0 I—1 P I
(- 1 1 1 \J n
1 1 1 1
\ j
0 1 1 o o O J o o
MULTI-ALARM INDICATION
RECEIVER MODULE
PART NO.32915
3-INCH ALARM BELL
PART NO.35650
iSZZSL e
1 1
SECONDARY
CONNECTION BOX
PART NO.37450
CARRYING
STRAP^ n CONNECTOR
BOX
PORTABLE
SECONDARY METER
PART NO.37495
Figure 1-10. Remote Alarm and Fluid Level Indicating Devices
ORIGINAL 1-11
STUFFING TUBE
3/4 INCH PIPE"
STUFFIN-G TUBE
PENETRATION ASSEMBLY
PART NO.36424
5 INCH FLANGE
5 INCH PIPE 15
STANDPIPE MOUNTING
PART N0.33000
TAPPED
HOLE
MOUNTING
PART NO.36407
PART NO. 36413
BRACKET ASSEMBLIES
PART NO.36409
. f ADJUSTABLE
" T C I INCH
INCREMENTS)
WELDING FIXTURE
PART NO. TRANSMITTER RANGE
(INCHES OF INDICATION)
36452 18 TO 36
36453 37 TO 75
36454 76 TO 150
ANGLE BRACKET
U-BOLT C-BOLT
"A" "B"
A . SOUNDING TUBE MOUNTING
BRACKET ASSEMBLY
PART NO. 31795-1-1/2" I PS
PART NO.32445-2" IPS
6.LADDER MOUNTING BRACKET
ASSEMBLY
PART N0.32579
Figure 1-11. Installation Accessories (Sheet 1 of 2)
1-12 ORIGINAL
PANEL MOUNTING RACK BULKHEAD MOUNTING RACK
NUMBER OF
RECEIVERS PART NO. NUMBER OF
RECEIVERS PART NO.
1 31304 1 31314
2 3130B 2 3I3IS
3 31 306 3 31316 4 31307 4 31317 5 31308 5 31318 6 31309 6 31319
Figure 1-11. Installation Accessories (Sheet 2 of 2) provides a liquid-tight penetration of a fluid tank bvdkhead. It consists of a stuffing tube and pipe sec tion. The pipe section is welded in a 1-1/16 in. tank hole and the stuffing tube tightened around a cable assembly passed through it.
f. Welding Fixtures. All welding by install ing activity. Welding fixtures. Part No. 36452, 36453, and 36454 provide a means of determining the installation position for bracket mounted trans mitters and a means of holding the transmitter mounting bracket assemblies during welding oper ations. The welding fixtures, which differ only in their overall height, consists of two concentric tubes.
The inner tube is slid up and down in the outer tube to achieve a desired distance between brackets that are a part of each tube. Welding fixture. Part No.
36452, has a range of 18 to 36 inches between brack ets; Part No. 36453 has a range of 37 to 75 inches between brackets; and Part No. 36454 has a range of 76 to 150 inches between brackets. The transmitters' "IN. of IND." is indicated t>y calibra tions marked on the inner tube at 1-inch intervals, see Part No. 36452, typical. A locking pin, which is held on the outer tube by a chain is passed through mating holes in both tubes to fix the distance between brackets at the desired value.
g. Mounting Racks. Two types of mounting racks are supplied for the mounting of receiver modules. One type is used for panel-mounted in stallations, the other for bulkhead-mounted install ations. Mounting racks. Part No. 31304 through 31309, are used to panel mount from one to six re ceiver modules, respectively. Mounting racks. Part No.