This is a solicitation for a C-130 contract depot maintenance and mid-cycle paint services contract to be awarded by the Air Force Materiel Command Lifecycle Management Center located at Robins Air Force Base. The five year IDIQ contract will address overflow C-130 UDLM/PDM and mid-cycle paint that cannot be completed organically at USAF air logistics complexes. Pricing will predominantly consist of firm fixed price with some cost reimbursement for travel, fuel, and over and above work. The best value source selection will result in one contract award to a CONUS offeror. Foreign companies are not eligible to participate.

View the file

Other files

File Type Posted
RFP_Atch_2_C130_UDLM_PDM_Pricing_Model_dtd_8Jan2020.xlsx XLSX spreadsheet
RFP_Atch_1_C130_PWS_UDLM_PDM_07Jan2020.pdf PDF
Amendment_ FA850420R0001_ 0001_dtd_16Jan20.pdf PDF
RFP_Atch_2_C130_UDLM_PDM_Pricing_Model_dtd_8Jan2020.pdf PDF
Revision 01 - Industry Questions with USG Responses to UDLM PDM RFP - 14 Jan 2020.pdf PDF
Industry_Questions_AF_Responses_UDLM_PDM_dtd_31Dec19.pdf PDF
RFP_Atch_4_C130_UDLM_PDM_DD_254_dtd_22Oct19.pdf PDF
RFP_Atch_11_C130_UDLM_PDM_Consent_Form_dtd_21Oct19.pdf PDF
C130_PWS_UDLM_PDM_App_F_C130HJ_ Work Control Document_Master Operations Coversheet_dtd_21Oct19.pdf PDF
RFP_Atch_9_C130_UDLM_PDM_Past_Performance_Questionnaire_dtd_5Nov19.pdf PDF
C130_PWS_UDLM_PDM_App_C_C130_FY19_CDMWA_dtd_21Oct19.pdf PDF
RFP_Atch_18_C130_UDLM_PDM_GFP_List_dtd_22Oct19.pdf PDF
C130_PWS_UDLM_PDM_App_F_C130HJ _ Work Cards_WCD _Master Operations_dtd_19Mar19.xlsx XLSX spreadsheet
RFP_Atch_8_C130_UDLM_PDM_Section_M_dtd_4 Nov 19.pdf PDF
C130_PWS_UDLM_PDM_App_H_Examples_dtd_ 2019 09 12.pdf PDF
RFP_Atch_7_C130_UDLM_PDM_Section_L_dtd_4Nov 19.pdf PDF
C130_PWS_UDLM_PDM_App_E_USG_IS_Access_Matrix_dtd_7Nov19.pdf PDF
C130_PWS_UDLM_PDM_App_A_C130HJ_Work_Spec_FY20_dtd_12Sep19.pdf PDF
C130_PWS_UDLM_PDM_App_B_C130HJ_Catalog_M_Task_FFP_List_dtd_31Oct19.pdf PDF
RFP_Atch_6_C130_UDLM_PDM_TO_Library_Access_Procedures_dtd_21OCT19.pdf PDF
RFP_Atch_13_C130_UDL_PDM_Relevancy_Table_dtd_5Nov19.pdf PDF
RFP_Atch_3_C130_UDLM_PDM_CDRLS_dtd_31Oct19.pdf PDF
RFP_Atch_10_C130_UDLM_PDM_Client_Authorization_Letter_dtd_21Oct19.pdf PDF
FA850420R0001 dtd 27 Nov 19.pdf PDF
RFP_Atch_12_C130_UDLM_PDM_Transmittal_Letter_dtd_21Oct19.pdf PDF
RFP_Atch_1_C130_PWS_UDLM_PDM_dtd_5Nov19.pdf PDF
C130_PWS_UDLM_PDM_App_D_C130J_Aircraft_Mid-Cycle_Paint_Work_Specs_dtd_21Oct19.pdf PDF
RFP_Atch_14_C130_UDLM_PDM_Electronic_Format_for_All_Proposal_Volumes_dtd_21Oct19.pdf PDF
RFP_Atch_2_C130_UDLM_PDM_Pricing_Model_dtd_31Oct19.xlsx XLSX spreadsheet
RFP_Atch_15_C130_UDML_PDM_PPI_for_Offerors_undated.pdf PDF
C130_PWS_UDLM_PDM_App_G_Acronym_List_dtd_21Oct19.pdf PDF
RFP_Atch_5_C130_UDLM_PDM_Packaging_Form_158_dtd_19Apr19.pdf PDF
RFP_Atch_16_C130_UDLM_PDM_PPI_Tool_undated.docx DOCX document
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Documents referenced were validated Sep 17.

You are responsible to verify you are referencing the correct/current versions.

ATTACHMENT - SAFETY

Safety and Health Requirements for:

PR/Contract/Project#: FD2060-19-32378

Date: 12 FEB 19

Type Work: C-130 Contract Depot Maintenance (UDLM/PDM)

PART I

Instructions: The Contractor Safety and Health Plan (required in accordance with AFI 91-202, AFMC Sup 1) shall address in detail the items listed in Parts II and III, as applicable. Repeating the referenced standard without addressing the company’s specific processes or procedures will not suffice. If task specific procedures are incorporated into a company local document, those procedures must be attached to the submitted Safety and Health Plan. Referencing the company's local procedure/document in the Safety and Health Plan is not adequate. If the company's local procedure/document is not attached, the submitted Safety Plan will be returned unacceptable.

PART II

1. Environmental, Safety, And Occupational Health (ESOH): The contractor is solely responsible for compliance with all federal, state and local laws, the Occupational, Safety and Health Act (Public Law 91-596) and the resulting standards, OSHA Standards 29 CFR 1910 and 1926, as applicable, and the protection of their employees. Additionally, the contractor is responsible for the safety and health of all subcontractor employees.

2. Contractor Employees: Compliance with OSHA and other applicable laws and regulations for the protection of contractor employees is exclusively the obligation of the contractor. Note: The Air Force Consolidated Occupational Safety Instruction (AFI 91-203) is frequently annotated because many of the Air Force Standards exceed the OSHA standard criteria. If a conflict is noted, the most stringent requirement takes precedence. The government shall assume no liability or responsibility for the contractor's compliance or non-compliance with such requirements. The contractor shall furnish to each of his/her employees a place of employment, which is free from recognized hazards. The contractor shall brief his/her employees on the safety requirements of this contract and on hazards associated with prescribed tasks. In addition, the contractor is required to flow down the safety requirements/specification to all subcontractors. This applies to Federal Acquisition Regulation (FAR) Part 12 commercial acquisitions as well. This contract shall in no way require persons to work in surroundings or under working conditions which are unsafe or dangerous to their health. The contractor must coordinate and perform work so as not to impact the safety of government employees or cause damage to government property. This requires providing personnel with protective equipment and associated safety equipment as may be necessary. The contractor must also protect personnel from hazards generated by the work. If the contractor employs bilingual speaking employees, they must post bilingual signs and have written procedures for specific tasks in applicable languages.

http://www.e-publishing.af.mil/?txtSearchWord=91-202&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=91-202&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=0 http://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=0 http://www.e-publishing.af.mil/shared/resource/EPubLibraryV3/EPubLibrary.aspx?type=Pubs&search_title=91-203 http://www.e-publishing.af.mil/shared/resource/EPubLibraryV3/EPubLibrary.aspx?type=Pubs&search_title=91-203 https://www.acquisition.gov/browsefar https://www.acquisition.gov/browsefar

You are responsible to verify you are referencing the correct/current versions.

3. Inspections: Air Force Environmental, Safety, Occupational Health and Fire protection officials or responsible Quality Assurance Evaluator (QAE) may periodically enter a contractor’s workplace to verify working conditions of Air Force personnel. If an Air Force employee observes improper procedures or unsafe conditions exits which place Air Force personnel or equipment/facilities in jeopardy, the contractor will remove personnel and/or equipment from the unsafe condition and immediately notify, via the Defense Contract Management Agency (DCMA) representative or the Contracting Officer, who will, in turn, notify the contracting unit’s Safety Office.

4. Mishap Notification: The contractor shall notify the DCMA representative of all mishaps or incidents for damage to DoD property (material plus labor) entrusted by this contract and employee injuries as a result of the contract operation. DCMA will notify the contracting unit’s Safety Office telephonically at 937-255-3395 (Aviation Safety) or 937-255-1988 (Ground Safety) during duty hours and 937-257-6314, AFMC Command Center after hours and ask for the AFLCMC/SE Director of Safety within four (4) business hours after initial notification A follow-up (written or e-mail) of this mishap/incident notification shall be sent within three calendar days to the Government Representative, the Procurement Contracting Officer (PCO) or the Administrative Contracting Officer (ACO) (with a copy to program manager), who will forward it to the contracting unit’s Safety Office (AFLCMC.SE@us.af.mil). The information that is not available at the time of the initial notification shall be provided within 20 calendar days after the mishap.

Mishap notification shall contain, as a minimum, the following information:

a. Contract, Contract Number, Name and Title of Person(s) Reporting

b. Date, Time and exact location of accident/incident

c. Brief Narrative of accident/incident (Events leading to accident/incident)

d. Cause of accident/incident, if known

e. Estimated cost of accident/incident (material and labor to repair/replace)

f. Impound Authority Name and Phone Number (as applicable)

g. Nomenclature of equipment and personnel involved in accident/incident

h. Corrective actions (taken or proposed)

i. Other pertinent information

Note: If requested by Government Personnel (PCO/ACO), the contractor shall immediately secure the mishap scene/damaged property and impound pertinent maintenance and training records, until released by the investigating safety office. If the government investigates the mishap, the contractor and the subcontractors shall cooperate fully and assist the government personnel until the investigation is finalized and closed out.

5. Impoundment Procedures: The contractor shall establish written impoundment procedures, as part of their Safety and Health Plan. Impound data must be included in the Mishap Notification Procedures as applicable. As a minimum, the procedures must address:

a. Appointment of Impound Authority in writing (copy faxed to QAP and Safety Office)

b. Impound Authority e-mail address and phone numbers file://RG0ABWCS0009001/uhd03/Valerie.Smith/-%20AFLCMC%20Safety%20WORK/__z%20other%20processes/Contracting%20stuff/1709%20update%20AppendC/AFLCMC.SE@us.af.mil

You are responsible to verify you are referencing the correct/current versions.

c. Specific instructions (cordon, facility locked facility, etc.) to secure the site or government asset, to prevent tampering with the aircraft, site or government assets

d. Specific instructions or measures to ensure only authorized personnel directly involved in management, SAFING, troubleshooting, or repair of aircraft or equipment gain access to the impound site

e. Additional guidance is located within AFI 21-101, AFMC Supplement 1

6. Contractor Safety and Health Program: The contractor shall establish and maintain an acceptable safety and health program.

a. Contractor Safety and Health Manager. As part of the Contractor Safety and Health Program, the contractor shall assign in their plan, by name and phone number, a person who will be the primary point of contact for safety and health issues for the on-site operation.

b. Contractor’s Safety and Health Plan. Contractor shall prepare a safety and health plan in accordance with PART I, PART II, and PART III, incorporating the listed elements in PART II and addressing in detail, as applicable, the items below in PART III of this Appendix.

(1) Government acceptance. The plan must be accepted by the government and will be incorporated into the awarded contract. Should a master safety and health plan remain on file with the contracting unit’s Safety Office, the contractor must ensure that it is current, updated, and includes all elements below. An addendum to the plan must include the processes noted below:

(2) Changes to the Plan. If, during the performance of this contract, changes to the contractor’s Safety and Health Plan are required, the contractor shall submit a revised Safety and Health Plan to the Contracting Monitor and/or Contracting Officer’s Representative (COR). The same process of review and negotiation (if applicable) involved in the original submission applies to any revision submitted after contract award. The accepted revised Safety and Health Plan shall then be incorporated by contract modification as an attachment or by reference.

PART III

The following items represent a list of required elements, as applicable, for the performance of this contract. The contractor’s safety and health plan shall address how compliance with these requirements will be ensured. The safety plan shall clearly define company procedures on specific tasks/processes, personnel qualifications, how facilities comply with fire requirements to include the electrical wiring and fire protection systems installed (i.e., fire suppression, fire detection, fire extinguishers, firewall ratings, etc.), required equipment used to accomplish tasks and other necessary requirements to ensure the protection of government personnel and property. The contractor’s safety and health plan shall meet, but may exceed the referenced standards.

http://www.e-publishing.af.mil/?txtSearchWord=21-101&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0

You are responsible to verify you are referencing the correct/current versions.

GENERAL – PEOPLE

1. Pedestrian Crosswalks: All contractor personnel are required to use the closest crosswalk, or traffic controlled intersection when crossing the road. Pedestrians must look both ways to ensure the coast is clear before stepping out into the crosswalk. Pedestrians do not have the right of way unless they are already in the crosswalk. Contractor vehicle operators have the same responsibilities as pedestrians, to share the road and mutually observe and yield to pedestrians.

2. Walking/Working Surfaces: Contractor shall comply with the standards in: 29 CFR 1910, Subpart D and NFPA 101-2015, Life Safety Code. All interior walking and working surfaces which are part of the means of egress shall remain clear at all times and comply with the requirements of NFPA 101-2015, Life Safety Code . Floors shall be kept in good condition and free of defects that can endanger workers or interfere with the handling of materials. Housekeeping – methods and controls are in place to minimize tripping hazards, the accumulation of flammable/combustible materials, etc. Portable metal ladders – methods and controls are in place to ensure inspection and safe use. Open-sided floors/platforms/runways must be protected and not left uncovered to prevent injury.

3. Housekeeping: Housekeeping shall be conducted according to the requirements in OSHA Standard 29 CFR 1910.141. Clean as you go will be enforced. Refuse, trash, and debris will be collected daily and not left on site to prevent hazards during high winds and inclement weather.

4. Confined Space Program Elements: Contractor shall comply with the standards in: 29 CFR 1910.120, 146 and 29 CFR 1926.21 and 353; and AFI 91-203, Air Force Consolidated Occupational Safety Instruction, 24 Jul 17, chapter 23. A confined space must meet the following three criteria:

(1) Is large enough and so configured that an employee can bodily enter and perform assigned work; and

(2) has limited or restricted means for entry or exit (for example, tanks, vessels, silos, storage bins, hoppers, vaults, and pits are spaces that may have limited means of entry.);

and

(3) is not designed for continuous employee occupancy. Examples: underground vaults, tanks, storage bins, manholes, pits, silos, process vessels, and pipelines.

Contractor’s Safety Plan shall address:

- Hazards of confined space

- Permit and Non-permit confined spaces

- Responsibilities of management, entry supervisor, authorized entrant, and authorized attendants

- Training requirements

- Permit handling and approval

- Emergency and rescue plans

- Testing and monitoring requirements

- Special hazards https://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=standards&p_id=9696 https://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=standards&p_id=9696 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=101 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=101 https://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=standards&p_id=9696 https://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=standards&p_id=9696 https://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=standards&p_id=9696 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926 http://static.e-publishing.af.mil/production/1/af_se/publication/afi91-203/afi91-203.pdf http://static.e-publishing.af.mil/production/1/af_se/publication/afi91-203/afi91-203.pdf

You are responsible to verify you are referencing the correct/current versions.

- Posting requirements (applicable to subcontractor operated facilities)

5. Personal Protective Equipment: Contractor shall comply with the standards in: 29 CFR 1910.132, 134, 136, Subpart I and 29 CFR 1926.28, 95, 100, 101, 102, and 951. Personnel protective equipment is required to be worn when employees are exposed to a potential hazard, working overhead, falling objects, etc. Contractor’s Safety Plan shall also address:

- Eye and face protection

- Head protection

- Foot Protection

- Electrical protective equipment

- Hand protection

- Safety harnesses, life lines, and lanyards

6. Respiratory Protection Program Elements: Contractor shall comply with the standards in: 29 CFR 1910.134 and 29 CFR 1926.134. Respirators are required to be worn if employees are exposed to inhalation hazard. Contractor’s Safety Plan shall also address:

- Training

- Medical evaluation

- Fit tests

- Selection of respiratory equipment

- Storage of respiratory equipment

- Pre-use checks

7. Hearing Conservation Program Elements: Contractor shall comply with the standards in: 29 CFR 1910.95 and 29 CFR 1926.52. Note: Noise exposures are based on ACGIH guidelines of 85 dB TWA. Contractor’s Safety Plan shall also address:

- Monitoring (survey of noise producing equipment)

- Audiometric testing

- Hearing Protectors

- Training

- Recordkeeping/Access to information and training material

8. Medical and First Aid: Contractor shall comply with the standards in: 29 CFR 1910, Subpart K and 29 CFR 1926, Subpart C. Contractor’s Safety Plan shall also address:

- Adequate first aid supplies

- Trained employee to render first aid

- Recordkeeping

- Reporting and investigating accidents/incidents

- Off-site physician(s)

- Maintenance of and employee access to exposure monitoring data and medical records https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926

You are responsible to verify you are referencing the correct/current versions.

ENVIRONMENTAL

9. Toxic and Hazardous Substances: Contractor shall comply with the standards in: 29 CFR 1910, Subpart Z and 29 CFR 1926, Subpart Z. Contractor’s Safety Plan shall also address a section related to working with toxic and hazardous substances, such as asbestos, benzene, lead, and styrene, where the following areas are addressed:

- Threshold Limit Values (TLV)-Exposure monitoring

- Medical surveillance

- Work practices

- Engineering controls

- Respiratory protection

- Protective clothing (PPE)

10. Hazardous Waste Operations: Contractor shall comply with the standards in: 29 CFR

1910.120 and 29 CFR 1926.65. Contractor’s Safety Plan shall also address:

- Emergency Response Plan

- Personal Protective Equipment

- Medical Surveillance

- Health and Safety Plan (HASP– required elements have been incorporated)

- Employee Training

11. Hazardous Materials: Contractor shall comply with the standards in: 29 CFR 1910.120, Subpart H –Hazardous Materials (chemicals, compressed air, acetylene, etc.). When handling the hazardous material the following must be accomplished: Compressed gases – training, handling, storage, use, and PPE; flammable and combustible liquids – training, handling, storage use, and PPE. Contractor’s Safety Plan shall also address:

- Training, handling, storage, use and PPE

- Explosives and blasting agents

- Dipping and coating operations

12. Hazardous Communications: Contractor shall comply with the standards in: 29 CFR

1910.1200 . Contractor’s Safety Plan shall also address:

- Written Program-list of hazardous chemicals

- Identify the hazardous chemical(s) - labeling system

- MSDS data sheet location

- Employee information and training-methods used to inform employees of the hazards, and precautionary measures

13. Welding, Cutting, and Brazing: Contractor shall comply with the standards in: 29 CFR

1910.251 thru 255 and 29 CFR 1926.102(b), 153, 453(b), AFI 91-203, Air Force Consolidated Occupational Safety Instruction, 15 Jun 12, chapter 27; NFPA 410, Standard on Aircraft https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=410

You are responsible to verify you are referencing the correct/current versions.

Maintenance, 2015 Edition, and NFPA 51B, Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, 2014 Edition. Contractor’s Safety Plan shall also address:

- Welding Permit Required from Fire Department

- Training/worker knowledge

- Equipment inspections, service, and use

- Fire protection and prevention

- Protective equipment & welding shields

- Health protection (PPE)

- Ventilation

- Cylinders and containers

- Cylinder storage

14. Batteries: Contractor shall comply with the standards for battery servicing in accordance with OSHA Standard 29 CFR 1910.178, 29 CFR 1910.305; and site specific applicable aircraft T.O.s.

GENERAL - EQUIPMENT

15. Motor Vehicles: Contractor shall comply with the standards in: DoD Directive 5525.4, Enforcement of State Traffic Laws on DoD Installations", 21 Nov 81, change 1 - Oct 89, paragraphs 3-4; DoDI 6055.4, DoD Traffic Safety Program, 20 Apr 09, change 2 - 23 Jan 13; AFI 91-207, USAF Traffic Safety Program, 16 Feb 17; and AFI 91-207, AFMC Sup 1, 11 Feb 14. Each applies to all persons at any time on an Air Force installation and includes all leased, owned, or privatized property including housing areas. In addition, AFI 13-213, Airfield Driving, 1 Jun 11, change 1 - 30 Jun 15, paragraph 2.8, and applicable local guidance applies to all contractors, sub-contractors, vendors, commercial delivery companies, and all other private business vehicles who operate anywhere on an Air Force installation, including the airfield (to include the industrial areas and any buildings or hangars located upon the airfield) in support of their mission. Note:

Installation commanders of all DoD installations in the United States and over which the United States has exclusive or concurrent legislative jurisdiction are delegated the authority to establish additional vehicular and pedestrian traffic rules and regulations for their installations. All persons on a military installation shall comply with locally established vehicular and pedestrian traffic rules and regulations. A person found guilty of violating, on a military installation, any State vehicular or pedestrian traffic law or local DoDI 5525.4, paragraph 3 – 4 instruction: Pursuant to the authority established in Enclosure 1, installation vehicular or pedestrian traffic rule or regulation made applicable to the installation under the provisions of this directive is subject to a fine of not more than $50 or imprisonment for not more than 30 days, or both, for each violation (40 U.S.C., Section 318c; Public Buildings, Property and Works, Section on Penalties, effective 22 Jan 02).

16. System Modification which Alters Form, Fit, or Function: Contractor shall comply with:

Mil Standard 882E, Standard Practice for System Safety, 11 May 2012; and AFI 63-101/20-101, Integrated Life Cycle Management, Acquisition / Logistics, 09 May 2017, for system modifications, which alter form, fit, or function.

http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=410 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=51B http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=51B https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 http://www.esd.whs.mil/Directives/issuances/dodd/ http://www.esd.whs.mil/Directives/issuances/dodd/ http://www.esd.whs.mil/Portals/54/Documents/DD/issuances/dodi/605504p.pdf http://www.e-publishing.af.mil/?txtSearchWord=91-207&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=91-207&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=91-207&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://static.e-publishing.af.mil/production/1/af_a3/publication/afi13-213/afi13-213.pdf http://www.esd.whs.mil/Directives/issuances/dodd/ https://www.gpo.gov/fdsys/pkg/USCODE-2001-title40/pdf/USCODE-2001-title40-chap4-sec318c.pdf http://www.system-safety.org/Documents/MIL-STD-882E.pdf

You are responsible to verify you are referencing the correct/current versions.

17. General Environmental Controls: Contractor shall comply with the standards in: 29 CFR 1910, Subpart G, 29 CFR 1910, Subpart J and 29 CFR 1926, Subpart D. Contractor’s Safety Plan shall also address:

- Sanitation-toilet and washing facilities

- Accident prevention signs and tags

MATERIAL RELATED

18. Materials Handling and Storage: Contractor shall comply with the standards in: 29 CFR 1926.250, 953, 957 and 29 CFR 1910.101, Subparts F, H & N; and 29 CFR 1910.178, Powered Industrial Truck. Contractor’s Safety Plan shall also address:

- Storage and handling of materials

- Disposal of trash from elevations

- Personnel lifting techniques--proper storage to prevent shifting, for stability, etc.

- Rigging (requirements, inspection, components, and qualifications)

- Equipment (use in handling materials)

- Industrial trucks (training, inspection, maintenance, and safe use)

19. Machinery and Machine Guarding: Contractor shall comply with the standards in: 29 CFR 1910, Subpart O. Contractor’s Safety Plan shall also address:

- Control of rotating parts, flying chips, and sparks

- Inspection

- Maintenance

20. Hand and Portable Powered Tools and other Hand-Held Equipment: Contractor shall comply with the standards in: 29 CFR 1910, Subpart P and 29 CFR 1926, Subpart I. Contractor’s Safety Plan shall also address:

- Inspection

- Proper use

- Guarding

- Maintenance

- Control of rotating parts, flying chips, and sparks

21. Painting and Paint Removal: Painting and paint removal shall be accomplished according to: T.O. 1-1-8 Application and Removal of Organic Coatings, Aerospace and Non-aerospace Equipment, 12 Jan 10, change 21 - 24 Aug 17; NFPA 33, Spray Application Using Flammable or Combustible Materials, 2016 Edition; and NFPA 410, Aircraft Maintenance 2015 Edition.

22. Cleaning/Corrosion Control for Avionics and Electronics: Corrosion removal and treatment shall be conducted according to: T.O. 1-1-689-3, Cleaning and Corrosion Control Volume III Avionics and Electronics, 15 Jan 16.

https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1910 https://www.osha.gov/pls/oshaweb/owasrch.search_form?p_doc_type=STANDARDS&p_toc_level=1&p_keyvalue=1926 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=33 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=33 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=410

You are responsible to verify you are referencing the correct/current versions.

AIR & LIQUIDS

23. Handling, Storage, and Use of Flammable/Combustible Liquids: Contractor shall comply with the standards in: NFPA 30, Flammable and Combustible Liquids Code, 2015 Edition; and NFPA 33 Spray Application Using Flammable or Combustible Materials, 2016 Edition.

24. Compressed Gas and Compressed Air Equipment: Contractor shall comply with the standards in: 29 CFR 1910.169, Subpart M. Contractor’s Safety Plan shall also address:

- Employee Training

- Inspections

- Storage and Handling

25. Liquid Gaseous Oxygen/Cryogenics: Contractor’s procedures shall comply with: AFI 91- 203, Air Force Consolidated Occupational Safety Instruction, 15 Jun 12, chapters 22 and 43; T.O.

00-25-172, Ground Servicing of Aircraft and Static Grounding/Bonding, 9 Aug 13, change 27-13 Mar 17 (all); and NFPA 51, Design & Installation of Oxygen–Fuel Gas Systems for Welding, Cutting, and Allied Processes, 2018 Edition.

ELECTRICAL

26. Electrical: Contractor shall comply with the standards in: 29 CFR 1910, Subpart S, 29 CFR 1926, Subpart K; AFI 91-203, Air Force Consolidated Occupational Safety Instruction, 15 Jun 12, chapter 8; and NFPA 70, National Electrical Code, 2017 Edition. Electrical wiring and equipment shall be a type listed by Underwriters Laboratory (UL) or another recognized listing agent.

Contractor’s Safety Plan shall also address:

- Selection and use of work practices

- Training (basic electrical safety knowledge)

- Use of equipment (handling, visual inspection, rating of equipment)

- GFCI Protection for outside contractor drops and wet/damp areas

- Arc Flash

27. Soldering: Soldering shall be conducted in accordance with the requirements in T.O. 00-25- 234, General Shop Practice Requirements for the Repair, Maintenance and Test of Electrical Equipment, 22 Sep 13, change 6 - 24 May 2017, chapter 3; and 29 CFR 1910.253.

28. Electronic/Electrostatic Discharge Sensitive Components: An electrostatic discharge program, when applicable, shall be implemented according to: MIL-HDBK-263B, Electrostatic Discharge Control Handbook for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices), 31 Jul 94; MIL-STD-1686C, Electrostatic Discharge Control Program for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices), 25 Oct 95; T.O.

00-25-234, General Shop Practice Requirements for the Repair, Maintenance and Test of Electrical Equipment, 22 Sep 13, change 6 - 24 May 2017; or the commercial standard ANSI/ESD http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=30 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=33 https://www.ecfr.gov/cgi-bin/text-idx?SID=82ed251e581d2eb236d0fa770fa3b3a1&mc=true&node=pt29.5.1910&rgn=div5 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=51B http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=51B https://www.ecfr.gov/cgi-bin/text-idx?SID=82ed251e581d2eb236d0fa770fa3b3a1&mc=true&node=pt29.5.1910&rgn=div5 https://www.ecfr.gov/cgi-bin/text-idx?SID=d284919a4ad8de2da14bf884b9776ff6&mc=true&node=pt29.8.1926&rgn=div5 https://www.ecfr.gov/cgi-bin/text-idx?SID=d284919a4ad8de2da14bf884b9776ff6&mc=true&node=pt29.8.1926&rgn=div5 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70 http://www.ul.com/ https://www.ecfr.gov/cgi-bin/text-idx?SID=82ed251e581d2eb236d0fa770fa3b3a1&mc=true&node=pt29.5.1910&rgn=div5 http://everyspec.com/MIL-HDBK/MIL-HDBK-0200-0299/MIL_HDBK_263B_162/ http://everyspec.com/MIL-HDBK/MIL-HDBK-0200-0299/MIL_HDBK_263B_162/ http://everyspec.com/MIL-HDBK/MIL-HDBK-0200-0299/MIL_HDBK_263B_162/ http://everyspec.com/MIL-STD/MIL-STD-1600-1699/MIL-STD-1686C_5522/ http://everyspec.com/MIL-STD/MIL-STD-1600-1699/MIL-STD-1686C_5522/ http://everyspec.com/MIL-STD/MIL-STD-1600-1699/MIL-STD-1686C_5522/

You are responsible to verify you are referencing the correct/current versions.

S20.20, Electrostatic Discharge Control Program-Protection of Electrical & Electronic Parts, Assemblies and Equipment, 31 Jul 14.

29. Hazardous Energy Control Program Elements (Lockout-Tagout): Contractor shall comply with the standards in: 29 CFR 1910, Subpart S, 29 CFR 1926, Subpart K; AFI 91-203, Air Force Consolidated Occupational Safety Instruction, 15 Jun 12, chapter 21; and NFPA 70 – National Electrical Code, 2017 edition. Contractor’s Safety Plan shall also address:

- Purpose of hazardous energy control program

- Employee training

- Lockout/Tagout procedures-Removal of locks and tags

- Periodic inspections

- Restoring equipment to normal operations

- Arc Flash

- Portable Fire Extinguishers (proper type, inspection, maintenance, testing, and training)

30. Grounding/Bonding of Aircraft and Avionics Equipment: Contractor shall comply with the standards for grounding and bonding in accordance with T.O. 00-25-172, Ground Servicing of Aircraft and Static Grounding/Bonding, 9 Aug 13, change 27-13 Mar 17, for aircraft repair and T.O. 00-25-234, General Shop Practice Requirements for the Repair, Maintenance and Test of Electrical Equipment, 22 Sep 13, change 6 - 24 May 2017, for avionics equipment.

AIRFIELD & FACILITIES

31. Airfield Criteria: Contractor furnished airfields shall comply with the standards in: AFI 10- 220, Contractor’s Flight and Ground Operations, 21 Aug 13; DCMA INST 8210.1C, Contractor’s Flight and Ground Operations, 21 Aug 13. NAS 3306, Facility Requirements for Aircraft Operations, Rev 3, 21 Nov 14, chapter 4 (available at Robins through IHS); and UFC 3- 260-01, Airfield and Heliport Planning and Design, 17 Nov 08; UFC 3-260-02, Pavement Design for Airfields, 30 Jun 01; AFI 32-2001, Fire Emergency Services (FES) Program, 27 Feb 14.

32. Foreign Object Damage (FOD) Awareness, Prevention And Responsibilities: Contractor shall comply with the standards in: AFI 21-101 AFMC Sup 1, Aircraft and Equipment Maintenance Management, 19 Jul 16, chapter 11; National Aerospace Standard (NAS) 412, Foreign Object Damage/Foreign Object Debris (FOD) Prevention Program, 1st Edition, 30 Sep 13; AFI 91-203, Air Force Consolidated Occupational Safety Instruction, 15 Jun 12, chapter 24;

and all applicable local guidance. The FOD program must be integrated into the day-to-day operations to reduce/eliminate FOD incidents. Programs will include covering waste dumpsters, waste hauling trucks, barriers in place to stop migrating FOD from dirt and gravel piles, and end of shift or daily clean-up. The contractor will brief their personnel at least weekly on any FOD requirements. All contractors, subcontractors performing maintenance in a FOD–potential area will receive and have documented initial FOD Awareness and Prevention training. Subject training will be given during Flight Line Drivers Training by the host Base Operations Flight. All vehicle operators are responsible for performing a Foreign Object (FO) inspection on their vehicles including all towed equipment, vehicle tires and open cargo areas of vehicles prior to entering the marked runway, taxiway, flight line, aircraft parking ramps and other areas as directed by the https://www.ecfr.gov/cgi-bin/text-idx?SID=82ed251e581d2eb236d0fa770fa3b3a1&mc=true&node=pt29.5.1910&rgn=div5 https://www.ecfr.gov/cgi-bin/text-idx?SID=d284919a4ad8de2da14bf884b9776ff6&mc=true&node=pt29.8.1926&rgn=div5 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70 http://www.e-publishing.af.mil/?txtSearchWord=10-220&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=10-220&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 https://media.defense.gov/2017/Mar/29/2001723705/-1/-1/0/CIM_13020_3A.PDF https://media.defense.gov/2017/Mar/29/2001723705/-1/-1/0/CIM_13020_3A.PDF https://ewb.ihs.com/#/document/RUSJJFAAAAAAAAAA?qid=636413938021572681&sr=re-1-10&kbid=4%7C20027&docid=940870974 https://ewb.ihs.com/#/document/RUSJJFAAAAAAAAAA?qid=636413938021572681&sr=re-1-10&kbid=4%7C20027&docid=940870974 https://www.wbdg.org/FFC/DOD/UFC/ufc_3_260_01_2008.pdf https://www.wbdg.org/FFC/DOD/UFC/ufc_3_260_01_2008.pdf https://www.wbdg.org/FFC/DOD/UFC/ufc_3_260_02_2001.pdf https://www.wbdg.org/FFC/DOD/UFC/ufc_3_260_02_2001.pdf http://www.e-publishing.af.mil/?txtSearchWord=32-2001&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=21-101&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=21-101&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0

You are responsible to verify you are referencing the correct/current versions.

Installation FOD Awareness and Prevention Officer. All “open-air” delivery vehicles must be free of loose items/debris that could potentially fall from the vehicle and cause a FOD hazard. The cargo beds of pickups truck must be clean or covered prior to entering the airfield. Vehicles will be subject to inspection and denied entry if found unacceptable. Contractors and site/operations evaluators will ensure tools; equipment, rags, residue and hardware are properly stored and accounted for. “Clean as you go” methods are required.

33. Aircraft Towing/Parking/Mooring: Towing, parking and mooring procedures must comply with AFI 11-218, Aircraft Operations and Movement on the Ground, chapter 1, section 1D, 28 Oct 11; AFI 91-203, Air Force Consolidated Occupational Safety Instruction, 15 Jun 12, Chap 24;

Unified Facility Code (UFC) 3-260-01, Airfield and Heliport Planning and Design, 17 Nov 08, and site specific applicable aircraft T.O.s.

34. Hangaring of Fueled Aircraft: Aircraft hangars where fueled aircraft will be stored must meet the facility requirements in NFPA 70, National Electrical Code, 2017 Edition; NFPA 409, Aircraft Hangars, 2016 Edition; NFPA 410, Aircraft Maintenance, 2015 Edition; and T.O. 1-1-3, Inspection and Repair of Aircraft Integral Tanks and Fuel Cells, 21 Jun 2013, change 26 - 4 Feb 17; and applicable “-2” series T.O.s.

35. Aircraft Jacking Operations: Contractor’s procedures shall comply with: 35A2 series T.O.s (various jacking equipment); AFI 91-203, Air Force Consolidated Occupational Safety Instruction, 15 Jun 12, chapter 24.8; ANSI B30.1, Jacks, Industrial Rollers, Air Casters, and Hydraulic Gantries, 2015; and site or aircraft specific applicable T.O.s.

36. Fueling/Defueling Operations: All fueling/defueling operations will be in compliance with:

T.O. 00-25-172, Ground Servicing of Aircraft and Static Grounding/Bonding, 9 Aug 13, change 27 - 13 Mar 17; and T.O. 1-1-3, Inspection and Repair of Aircraft Integral Tanks and Fuel Cells, 21 Jun 13, change 26 - 4 Feb 17.

37. Fire Protection For Facilities: Contractor’s procedures shall comply with: NFPA 10, Portable Fire Extinguishers, 2013 Edition; NFPA 13, Installation of Sprinkler Systems, 2016 Edition; NFPA 33, Spray Application Using Flammable or Combustible Materials, 2016 Edition;

NFPA 70, National Electrical Code, 2017 Edition; NFPA 72, National Fire Alarm and Signaling Code, 2016 Edition; NFPA 91, Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids, 2015 Edition; NFPA 409, Aircraft Hangars, 2016 Edition; NFPA 410, Aircraft Maintenance, 2015 Edition; NFPA 418, Heliports, 2016 Edition; and NAS 3306, Facility Requirements for Aircraft Operations, Rev 3, 21 Nov 14, chapter 4 (available at Robins through IHS); AFI 32-2001, Fire Emergency Services (FES) Program, 27 Feb 14.

38. Airfield Rescue and Firefighting Capabilities: Contractor furnished fire trucks, personnel and training must meet the requirements in: NFPA 403, Aircraft Rescue and Fire-Fighting Services at Airports, 2018 Edition; NFPA 412, Evaluating Aircraft Rescue and Fire-Fighting Foam Equipment, 2014 Edition; NFPA 414, Aircraft Rescue and Fire-Fighting Vehicles, 2017 Edition; NAS 3306, Facility Requirements for Aircraft Operations, Rev 3, 21 Nov 14, chapter 4 (available at Robins through IHS);, paragraphs 5.3 through 5.5.1; AFI 32-2001, Fire Emergency Services (FES) Program, 27 Feb 14.

http://www.e-publishing.af.mil/?txtSearchWord=11-218&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 https://www.wbdg.org/FFC/DOD/UFC/ufc_3_260_01_2008.pdf http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=409 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=409 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=410 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/?txtSearchWord=91-203&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=10 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=10 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=13 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=33 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=72 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=72 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=91 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=91 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=409 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=410 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=410 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=418 https://ewb.ihs.com/#/document/RUSJJFAAAAAAAAAA?qid=636413938021572681&sr=re-1-10&kbid=4%7C20027&docid=940870974 https://ewb.ihs.com/#/document/RUSJJFAAAAAAAAAA?qid=636413938021572681&sr=re-1-10&kbid=4%7C20027&docid=940870974 http://www.e-publishing.af.mil/?txtSearchWord=32-2001&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=403 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=403 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=412 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=412 http://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=414 https://ewb.ihs.com/#/document/RUSJJFAAAAAAAAAA?qid=636413938021572681&sr=re-1-10&kbid=4%7C20027&docid=940870974 http://www.e-publishing.af.mil/index.asp?txtSearchWord=32-2001&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 http://www.e-publishing.af.mil/index.asp?txtSearchWord=32-2001&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0

39. Severe Weather Plan: Contractor shall comply with the standards in: NAS 3306, Facility Requirements for Aircraft Operations, Rev 3, 21 Nov 14, chapter 4 (available at Robins through IHS); AFI 10-220, Contractor’s Flight and Ground Operations, 21 Aug 13, paragraphs 5.1.2.25 – 5.1.2.25.6; and DCMA INST 8210.1C, Contractor’s Flight and Ground Operations, 21 Aug 13.

Contractor’s Safety Plan shall also address instructions for personnel, equipment and debris.

AIRCRAFT SPECIFIC

40. Aircraft Maintenance: Contractor shall comply with the standards in: AFI 91-203, Air Force Consolidated Occupational Safety Instruction, 15 Jun 12, chapter 24; AFI 21-101, Aircraft and Equipment Maintenance Management, 21 May 2015; and site specific applicable aircraft T.O.s.

41. Safing/Egress/Escape Systems: Contractor shall comply with the standards in: T.O. 11A-1- 33, Handling and Maintenance of Explosives-Loaded Aircraft, 31 Jul 17; and site specific applicable aircraft T.O.s.

42. Cleaning/Corrosion Control of Aircraft: Corrosion removal and treatment shall be conducted according to: T.O. 1-1-691, Cleaning and Corrosion Prevention and Control, Aerospace and Non-Aerospace Equipment, 2 Nov 09, change 14 - 13 Jul 17.

43. Aircraft Painting and Paint Removal Operations: Contractor shall comply with the standards in: T.O. 1-1-8, Application and Removal of Organic Coatings, Aerospace and Non-aerospace Equipment, 12 Jan 10, change 21 - 24 Aug 17; NFPA 33, Spray Application Using Flammable or Combustible Materials, 2016 Edition; NFPA 70, National Electrical Code, 2017 Edition; NFPA 91, Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids, 2015 Edition; NFPA 409, Aircraft Hangars, 2016 Edition; NFPA 410, Aircraft Maintenance, 2015 Edition; and site specific applicable aircraft T.O.s.

44. Fluid Purging of Aircraft: Aircraft fuel tanks must be fluid purged in accordance with T.O.

1-1-3, Inspection and Repair of Aircraft Integral Tanks and Fuel Cells, dated 21 Jun 13, Change 26 - 4 Feb 17.

45. Fuel Tank /Fuel Cell Repair: Fuel tank/cell work will be accomplished in accordance with the requirements in T.O. 1-1-3, Inspection and Repair of Aircraft Integral Tanks and Fuel Cells, dated 21 Jun 13, change 26 - 4 Feb 17; and site or aircraft specific applicable T.O.s.

46. Fuel Tank/Cell Foam Removal/Drying/Storage and Installation: Contractor’s procedures shall comply with T.O. 1-1-3, Inspection and Repair of Aircraft Integral tanks and Fuel Cells, 21 Jun 13, change 26 - 4 Feb 17; and site or aircraft specific applicable T.O.s.

47. Remove/Install Aircraft Engines: Contractor shall comply with the procedures in:

Appropriate engine T.O., and site specific applicable aircraft T.O.s.

48. On-Aircraft Engine Operations/Engine Runs: Contractor’s procedures must comply with AFI 11-218, Aircraft Operations and Movement on the Ground, Chap 1, Sect 1D, 28 Oct 11; site https://ewb.ihs.com/#/document/RUSJJFAAAAAAAAAA?qid=636413938021572681&sr=re-1-10&kbid=4%7C20027&docid=940870974 https://ewb.ihs.com/#/document/RUSJJFAAAAAAAAAA?qid=636413938021572681&sr=re-1-10&kbid=4%7C20027&docid=940870974 http://www.e-publishing.af.mil/?txtSearchWord=10-220&client=AFPW_EPubs&proxystylesheet=AFPW_EPubs&ie=UTF-8&oe=UTF-8&output=xml_no_dtd&site=AFPW_EPubs&btnG.x=0&btnG.y=0 https://media.defense.gov/2017/Mar/29/2001723705/-1/-1/0/CIM_13020_3A.PDF…