C130_PWS_UDLM_PDM_App_F_C130HJ _ Work Cards_WCD _Master Operations_dtd_19Mar19.xlsx

XLSX spreadsheet 4 MB Posted

Attached to
C-130 Contract Depot Maintenance (UDLM/PDM)
Solicitation number
FA850420R0001
Issued by

About this file

This document provides details for a forthcoming solicitation for C-130 Contract Depot Maintenance and Mid-Cycle Paint services. The Air Force Materiel Command Lifecycle Management Center at Robins Air Force Base will issue a request for proposal for a five-year indefinite delivery/indefinite quantity contract to address overflow C-130 Unscheduled Depot Level Maintenance and Programmed Depot Level Maintenance that cannot be completed organically. The contract will utilize predominantly firm fixed price arrangements with a mixture of other pricing terms for travel, fuel, and over and above work. The solicitation seeks a best value source selection per FAR 15 and intends to award one contract for services within the CONUS region to a single offeror, excluding foreign companies from participating.

View the file

Other files

File Type Posted
RFP_Atch_2_C130_UDLM_PDM_Pricing_Model_dtd_8Jan2020.xlsx XLSX spreadsheet
RFP_Atch_1_C130_PWS_UDLM_PDM_07Jan2020.pdf PDF
Amendment_ FA850420R0001_ 0001_dtd_16Jan20.pdf PDF
RFP_Atch_2_C130_UDLM_PDM_Pricing_Model_dtd_8Jan2020.pdf PDF
Revision 01 - Industry Questions with USG Responses to UDLM PDM RFP - 14 Jan 2020.pdf PDF
Industry_Questions_AF_Responses_UDLM_PDM_dtd_31Dec19.pdf PDF
RFP_Atch_4_C130_UDLM_PDM_DD_254_dtd_22Oct19.pdf PDF
RFP_Atch_11_C130_UDLM_PDM_Consent_Form_dtd_21Oct19.pdf PDF
C130_PWS_UDLM_PDM_App_F_C130HJ_ Work Control Document_Master Operations Coversheet_dtd_21Oct19.pdf PDF
RFP_Atch_9_C130_UDLM_PDM_Past_Performance_Questionnaire_dtd_5Nov19.pdf PDF
C130_PWS_UDLM_PDM_App_C_C130_FY19_CDMWA_dtd_21Oct19.pdf PDF
RFP_Atch_18_C130_UDLM_PDM_GFP_List_dtd_22Oct19.pdf PDF
RFP_Atch_8_C130_UDLM_PDM_Section_M_dtd_4 Nov 19.pdf PDF
C130_PWS_UDLM_PDM_App_H_Examples_dtd_ 2019 09 12.pdf PDF
RFP_Atch_7_C130_UDLM_PDM_Section_L_dtd_4Nov 19.pdf PDF
C130_PWS_UDLM_PDM_App_E_USG_IS_Access_Matrix_dtd_7Nov19.pdf PDF
C130_PWS_UDLM_PDM_App_A_C130HJ_Work_Spec_FY20_dtd_12Sep19.pdf PDF
C130_PWS_UDLM_PDM_App_B_C130HJ_Catalog_M_Task_FFP_List_dtd_31Oct19.pdf PDF
RFP_Atch_6_C130_UDLM_PDM_TO_Library_Access_Procedures_dtd_21OCT19.pdf PDF
RFP_Atch_13_C130_UDL_PDM_Relevancy_Table_dtd_5Nov19.pdf PDF
RFP_Atch_3_C130_UDLM_PDM_CDRLS_dtd_31Oct19.pdf PDF
RFP_Atch_10_C130_UDLM_PDM_Client_Authorization_Letter_dtd_21Oct19.pdf PDF
RFP_Atch_17_C130_UDLM_PDM_Safety_dtd_12Feb29.pdf PDF
FA850420R0001 dtd 27 Nov 19.pdf PDF
RFP_Atch_12_C130_UDLM_PDM_Transmittal_Letter_dtd_21Oct19.pdf PDF
RFP_Atch_1_C130_PWS_UDLM_PDM_dtd_5Nov19.pdf PDF
C130_PWS_UDLM_PDM_App_D_C130J_Aircraft_Mid-Cycle_Paint_Work_Specs_dtd_21Oct19.pdf PDF
RFP_Atch_14_C130_UDLM_PDM_Electronic_Format_for_All_Proposal_Volumes_dtd_21Oct19.pdf PDF
RFP_Atch_2_C130_UDLM_PDM_Pricing_Model_dtd_31Oct19.xlsx XLSX spreadsheet
RFP_Atch_15_C130_UDML_PDM_PPI_for_Offerors_undated.pdf PDF
C130_PWS_UDLM_PDM_App_G_Acronym_List_dtd_21Oct19.pdf PDF
RFP_Atch_5_C130_UDLM_PDM_Packaging_Form_158_dtd_19Apr19.pdf PDF
RFP_Atch_16_C130_UDLM_PDM_PPI_Tool_undated.docx DOCX document
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Master Operations

DCDWRK_SPEC_CDTYP_OP_CDOP_NROP_DESCDEF_GUIDEWRK_CATWRK_CAT_DESCCFG_STRCONTROL_STRMDS_STRThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV98N14002THIS OPERATION TO BE USED FOR G005M SUPPLY

(PARTS) CONTROL ONLY. USE THIS OP FOR ORDERING OUTER WING PARTS ONLY NO TECH DATA REQUIRED

***DO NOT COMPLETE OP UNTIL ALL CELL REQUIREMENTS ARE COMPLETE***

REMIS INPUT NOT REQUIRED

N611SUPPORT OPSLTWGOVERHL RTWGOVERHL00076B 100, 00112H 100C130H, 07000, , ,The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71552***DONOR WING*** INSTALL HYDRAULIC PUMP BY-PASS PLUMBING REMOVED FROM INCOMING WINGS ONTO DONOR WINGS TO CONFORM WITH NO.1 AND NO.4 DRY BAY HYDRAULIC PUMP MODIFICATIONS. IAW 3307014-1 AND 3307014-7. OBSREVE ALL NOTES, CAUTIONS, AND WARNINGS.N604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 45000, 799, Q, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71556***DONOR WING***

(#4 TANK) INSTALL NEW FUEL QUANTITY WIRING HARNESS

1C-130H-2-28JG-40-1, 1C-130H-2-13, 1-1A-14, 1C-130H-4-28-1

& DWG 3328457 . OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

1C-130-2-WA-2 FOR IMIS TECH DATAN604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 4663C, 799, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26753CONFIRMATION OF COMPLIANCE WITH TCTO HC-130-928011. INSTALLATION OF OUTER WING TANK AUXILIARY VENT VALVE.

REF: HC-130-928011

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HV92801100076B 100, 00116B 100C130H, 11000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26751CONFIRMATION OF COMPLIANCE WITH TCTO HC-130-921040. REPLACING THE CRITICAL BLEED AIR DUCTS IDENTIFIED BY THE AIR FORCE AS HAVING A HISTORY OF PREMATURE FAILURE.

REF: HC-130-921040

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HV99000076B 100, 00116B 100C130H, 11000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E774INSTALL ANGEL BRACKET & MAFFS BREAKOUT BOX. FS: 245

IAW: 202# C-130-15-01004, MAFFS TCTO USCGT DRAFT ATTACHMENT: PARA 7; STEPS: HH-II.

* OBSERVE ALL WARNINGS, CAUTIONS AND NOTES. CLEAN AREA.

* 1C-130-2-WA-2 FOR IMIS TECH DATAN604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E55375**DONOR WING** COMPLY WITH TCTO 1C-130-1826 LEFT WING

IAW ATTACHED DEFINITIZED GUIDE

CLEAN FOD CHECK AREA

OBSERVE ALL NOTES, CAUTIONS AND WARNINGS.

REF: 1-1A-8

NOTE: IF TCTO HAS RESCINDED SUBMIT 202 FOR AUTHORIZATION.Y602INSPECT HVLTWGOVERHL00076B 100, 00116B 100C130H, 14413, 800, S, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E55399**DONOR WING** RIGHT WING, COMPLY WITH REQUIREMENTS OF DEF GUIDE 55376 (TCTO 1C-130-1826, "INSPECTION AND COLD WORK OF HOLES IN RIB ATTACH TEE AT FLAP STA 28.17")

NOTE: IF TCTO HAS RESCINDED SUBMIT 202 FOR AUTHORIZATION.

N602INSPECT HVRTWGOVERHL00076B 100, 00116B 100C130H, 11500, 425, R, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71544***DONOR WING***

PERFORM CLOSING INSPECTION AND INSTALL LT WING TIP.

REF: PROCESS ORDER AMXG-06-235-075 (2 PAC REQD)

REF:1C-130H-2-51JG-00-1. 51-20-02. OBSERVE ALL NOTES, CAUTIONS, & WARNINGS. CLEAN AREA.

ENSURE THERE IS NO MAGNETIC HARDWARE REF:1C-130-2-WA-2 FOR IMIS TECH DATA

NOTE: SPECIAL ATTENTION TO CHECK ALL (4) ATTACH POINTS

NOTE: F.0./RAG INSP COMPLIED WITHN604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 1151J, 800, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E62105PERFORM A DETAIL VISUAL INSPECTION (DVI) OF THE OUTER WING AFT NACELLE EXPOSED AREA LOCATED UNDERNEATH #4 AFT NACELLE. OWS: 160-200

IAW: 1C-130-23, ITEM W-10.

REF: 1C-130A-36, 15-20-00 AND 33B-1-1

OBSERVE WARNINGS, CAUTIONS & NOTES.

ICARR REPORTING REQUIREDN602INSPECT HVRWGSWAPPRP00076B 100, 00116B 100C130H, 03600, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E773TERMINATE CONNECTORS (J155, J156,J158)

AT MAFFS BREAKOUT BOX. FS 245.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7; STEPS: V-GG.

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E762CONFIRMATION ONLY <><> TCTO 1C-130-1982 <><>

INSTALL BREAKOUT BOX FOR AC POWER FOR THE ROLL-ON/ROLL-OFF MAFFS

DATA CODE: 0191288

TCTO DATE: 12 FEB 2008

RECISSION DATE: 12 FEB 2010.

1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN611SUPPORT OPSTCTO198200076B 100, 00116B 100C130H, 95000, 799, Q, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71600(#1 TANK) VISUALLY INSPECT ALL REMOVED #1 FUEL TANK

PLUMBING AND HARDWARE FOR SERVICEABILITY &

PEELING/LOOSE POLYURETHANE, MIL-C-83019

IAW: 1C-130H-2-00GE-00-1 PARA 5-4.8.13;

42E1-1-1, 010 00 PARA 5 AND 014 00

NOTE: RECORD ALL DAMAGED PARTS IN ''U'' BOOK

NOTE: SECONDARY PAC REQ'D

IAW 1C-130-2-WA-2 FOR IMIS TECH DATAN602INSPECT HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46200, 800, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71165**DONOR WING** CLEAN AND LABEL RIGHT OUTER WING UPPER AND LOWER RAINBOW FITTINGS <><> OW-1, OW-2 <><> SEE DEF GUIDE ATTACHED.

REF: 1C-130A-36 & 1C-130A-3, FIG 51-100-07

OBSERVE ALL CAUTIONS, NOTES, WARNINGS;

CLEAN AREA AND CHECK FOR FO.

Y602INSPECT HVLTWGOVERHL00076B 100, 00116B 100C130H, 115BA, 799, W, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71283**DONOR WING** (#1 TANK) REMOVE ACCESS DOOR " D " FROM

TOP OF L/O/W.

REF:1C-130H-2-28JG-00-1, 28-00-10

DO NOT USE IMPACT TOOLS TO REMOVE DOORS.

CLEAN AREA.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 1151E, 804, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71284**DONOR WING** (#1 TANK) REMOVE ACCESS DOOR " C " FROM TOP OF L/O/W.

REF:1C-130H-2-28JG-00-1, 28-00-10.

DO NOT USE IMPACT TOOLS TO REMOVE DOORS.

CLEAN AREA.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 1151E, 804, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71286**DONOR WING** (#1 TANK) REMOVE "B" PANEL FUEL LEVEL CONTROL VALVE FOR TURN-IN TO SUPPLY.

NOTE: CAP LINE OPENINGS WITH APPROVED METHOD.

REF:1C-130H-2-28JG-20-1. 28-21-15

OBSERVE ALL NOTES, CAUTIONS & WARNINGS.

CLEAN AREA.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46314, 804, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71290**DONOR WING** THIS OPERATION IS FOR TIME TO SUPPORT DEPAINT BY ALTERNATELY RAISING AND LOWERING WING DOLLY SHORINGS SO ALL LOWER SURFACES OF WINGS CAN BE DE-PAINTED.

NO TECH DATA REQUIRED.

N611SUPPORT OPSLWGSWAPPRP RWGSWAPPRP00076B 100, 00116B 100C130H, 1411S, 804, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71292**DONOR WING** (#1 TANK) REMOVE THE BOOST PUMP FOR TURN IN TO SUPPLY. CAP OPEN LINES.

REF: 1C-130H-2-28JG-20-1, 28-22-11.

CLEAN AREA. 1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46211, 800, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71293**DONOR WING** (#1 TANK) REMOVE DUMP PUMP FOR TURN IN TO SUPPLY. CAP OPEN LINES.

IAW:1C-130H-2-28JG-30-1, 28-30-10

OBSERVE ALL NOTES, CAUTIONS & WARNINGS. CLEAN AREA.

IAW 1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46214, 800, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E62104PERFORM A DETAIL VISUAL INSPECTION (DVI) OF THE OUTER WING AFT NACELLE EXPOSED AREA LOCATED UNDERNEATH #1 AFT NACELLE. OWS: 160-200

IAW: 1C-130-23, ITEM W-10.

REF: 1C-130A-36, 15-20-00 AND 33B-1-1

OBSERVE WARNINGS, CAUTIONS & NOTES.

ICARR REPORTING REQUIREDN602INSPECT HVLWGSWAPPRP00076B 100, 00116B 100C130H, 03600, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E76050**DONOR WING** (#1 TANK) RINSE AWAY LOOSE POLYURETHANE IN SURGE BOX EJECTOR WITH CLEAN WATER. DO NOT TO EXCEED 100 PSI.

1C-130H-2-00GE-00-1

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVDONORPOLYL00076B 100, 00077B 100, 00078B 100, 00079B 100, 00080B 100, 00082B 100, 00083B 100, 00085B 100C130E, 461AA, 230, V, S; C130H, 461AA, 230, V, S; HC130N, 461AA, 230, V, S; HC130P, 461AA, 230, V, S; WC130H, 461AA, 230, V, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E76052**DONOR WING** (#2 TANK) RINSE AWAY LOOSE POLYURETHANE IN SURGE BOX EJECTOR WITH CLEAN WATER. DO NOT TO EXCEED 100 PSI.

1C-130H-2-00GE-00-1

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVDONORPOLYL00076B 100, 00077B 100, 00078B 100, 00079B 100, 00080B 100, 00082B 100, 00083B 100, 00085B 100C130E, 461AA, 230, V, S; C130H, 461AA, 230, V, S; HC130N, 461AA, 230, V, S; HC130P, 461AA, 230, V, S; WC130H, 461AA, 230, V, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E76053**DONOR WING** (#4 TANK) RINSE AWAY LOOSE POLYURETHANE IN SURGE BOX EJECTOR WITH CLEAN WATER. DO NOT TO EXCEED 100 PSI.

1C-130H-2-00GE-00-1

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVDONORPOLYR00076B 100, 00077B 100, 00078B 100, 00079B 100, 00080B 100, 00082B 100, 00083B 100, 00085B 100C130E, 461AA, 230, V, S; C130H, 461AA, 230, V, S; HC130N, 461AA, 230, V, S; HC130P, 461AA, 230, V, S; WC130H, 461AA, 230, V, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26752ACCOMPLISH TCTO HC-130-928011 INSTALLATION OF OUTER WING TANK AUXILIARY VENT VALVE. SEE ATTACHED DEF GUIDE.

IAW: TCTO HC-130-928011. OBSERVE ALL NOTES,WARNINGS, AMD CAUTIONS.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY602INSPECT HV92801100076B 100, 00116B 100C130H, 4614F, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26754ACCOMPLISH TCTO HC-130-928040. REMOVAL OF THE SCUPPER OVERFLOW DRAIN LINES ON ALL FUEL TANKS LOCATED IN THE FLAP WELL. SEE ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS. IAW TCTO HC-130-928040.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY602INSPECT HV92804000076B 100, 00116B 100C130H, 46WA4, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26755CONFIRMATION OF COMPLIANCE WITH TCTO HC-130-928040. REMOVAL OF THE SCUPPER OVERFLOW DRAIN LINES ON ALL FUEL TANKS LOCATED IN THE FLAP WELL.

REF: HC-130-928040

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HV92804000076B 100, 00116B 100C130H, 11000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26756ACCOMPLISH TCTO HC-130-928050. REMOVE THE SCUPPER OVERFLOW DRAIN LINES INSIDE ALL OF THE FUEL TANKS. IAW TCTO HC-130-928050. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAN602INSPECT HV92805000076B 100, 00116B 100C130H, 46WA4, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71542***DONOR WING***

INSTALL WIRING REMOVED FROM THE INCOMING LT WING TRAILING EDGE TO SATISFY THE OUTER WING SWAP. SEE ATTACHED DEF GUIDE. REF: 1-1A-14. OBSERVE ALL NOTES, CAUTIONS & WARNINGS.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 42000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71543***DONOR WING***

INSTALL WIRING REMOVED FROM THE INCOMING RT WING TRAILING EDGE TO SATISFY THE OUTER WING SWAP. SEE ATTACHED DEF GUIDE. REF: 1-1A-14. OBSERVE ALL NOTES, CAUTIONS & WARNINGS.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 42000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71548***DONOR WING***

(#1 TANK) INSTALL 5 FUEL PROBES & 1 COMPENSATOR

REF 1C-130H-2-28JG-40-1. OBSERVE ALL WARNINGS, CAUTIONS & NOTES.

1C-130-2-WA-2 FOR IMIS TECH DATAN604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 4663D, 800, Q, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E796GAIN ACCESS & PERFORM OPS CHECK ON DISTRUBED SYSTEMS

DUE TO MAFFS MOD.

REF: 1C-130-2059

REFERENCE DEF GUIDE FOR TECH DATAY605OPS CHECKTCTO205900076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E777ROUTE & TERMINATE MAFFS WIRING.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7; STEPS: JJ-MM

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E778TERMINATE WIRING AT K53A & K53C

FS: 245.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7 STEPS: NN THRU SS

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E76051**DONOR WING** (#3 TANK) RINSE AWAY LOOSE POLYURETHANE IN SURGE BOX EJECTOR WITH CLEAN WATER. DO NOT TO EXCEED 100 PSI.

1C-130H-2-00GE-00-1

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVDONORPOLYR00076B 100, 00077B 100, 00078B 100, 00079B 100, 00080B 100, 00082B 100, 00083B 100, 00085B 100C130H, 461AA, 230, V, S; HC130N, 461AA, 230, V, S; HC130P, 461AA, 230, V, S; WC130H, 461AA, 230, V, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71545***DONOR WING***

PERFORM CLOSING INSPECTION AND INSTALL RT WING TIP.

REF:1C-130H-2-51JG-00-1. 51-20-02. OBSERVE ALL NOTES, CAUTIONS, & WARNINGS. CLEAN AREA.

REF: PROCESS ORDER AMXG-06-235-075 (2 PAC REQD)

ENSURE THERE IS NO MAGNETIC HARDWARE

1C-130-2-WA-2 FOR IMIS TECH DATA

NOTE: SPECIAL ATTENTION TO CHECK ALL (4) ATTACH POINTS

NOTE: F.0./RAG INSP COMPLIED WITHN604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 1151J, 800, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71297**DONOR WING** (#2 TANK) REMOVE THE WATER SUCTION TUBES AND NOZZLES FROM #2 TANK, 3RD CAVITY, OUTBOARD OF THE SURGE BOX, TO SUPPORT NDI [OW-11] OR POLY REMOVAL. CAP OPEN LINES, BAG, TAG AND STORE PARTS FOR REINSTALLATION.
REF 1C-130H-2-28JG-20-1, 28-23-01 1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 461AB, 799, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71298**DONOR WING** (#2 TANK) REMOVE THE WATER SUCTION TUBES, SUPPORTS AND NOZZLES FROM #2 TANK FIRST CAVITY, OUTSIDE THE SURGE BOX, TO SUPPORT NDI [OW-8] OR POLY REMOVAL. CAP OPEN LINES, BAG, TAG, AND STORE PARTS FOR REINSTALLATION.
REF 1C-130H-2-28JG-20-1, 28-23-01 1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 461AB, 799, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71299**DONOR WING** (#2 TANK) REMOVE THE FUEL TANK ACCESS DOOR AT OWS 0.0 FOR TANK ENTRY. BAG & TAG BOLTS

STORE WITH DOOR FOR REINST. USE RUBBER MATS

TO PROTECT BOTTOM OF TK.

REF:1C-130H-2-28JG-00-1, 28-00-10 1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 1151E, 804, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71300**DONOR WING** (#2 TANK) REMOVE THE DIAGONAL BRACES FOR ACCESS IN THE #2 TANK.

INSPECT, BAG, TAG AND STORE PARTS FOR REINSTALLATION.

SEE ATTACHED DEF GUIDE.

REF:1C-130H-2-28JG-00-1, 28-00-10

1-1A-8 PARA 3.1.36

CLEAN AREA. 1C-130-2-WA-2 FOR IMIS TECH DATAY601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46118, 804, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71301**DONOR WING** (#2 TANK) REMOVE THE OUTBOARD SURGE BOX TOP PANEL IN #2 TANK, 2ND CAVITY. INSPECT, BAG, TAG, & STORE PARTS FOR REINSTALLATION.

REF:1C-130H-2-28JG-00-1 28-00-10

1-1A-8 PARA 3.1.36

OBSERVE NOTES, CAUTIONS AND WARNINGS. CLEAN AREA.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46113, 804, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71303**DONOR WING** (#2 TANK) REMOVE THE INBOARD SURGE BOX TOP PANEL IN #2 TANK, 1ST CAVITY.

INSPECT, BAG, TAG, & STORE PARTS FOR REINSTALLATION.

REF:1C-130H-2-28JG-00-1, 28-00-10 AND 1-1A-8.

OBSERVE NOTES, CAUTIONS AND WARNINGS. CLEAN AREA.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46113, 804, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71304**DONOR WING** (#2 TANK) REMOVE ENGINE FUEL FEED LINE, #2 TANK 1ST CAVITY FOR ACCESS. CAP OPEN LINES, INSPECT, BAG, TAG AND STORE PARTS FOR REINSTALLATION.

REF:1C-130H-2-28JG-00-1, 28-00-22.

OBSERVE NOTES, CAUTIONS AND WARNINGS. CLEAN AREA.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 462A0, 804, P, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71305**DONOR WING** (#2 TANK) REMOVE DUMP PUMP FOR TURN IN TO SUPPLY. CAP OPEN LINES

IAW:1C-130H-2-28JG-30-1, 28-30-10

OBSERVE ALL NOTES, CAUTIONS & WARNINGS. CLEAN AREA. IAW 1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46214, 800, Q, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26768CONFIRMATION OF COMPLIANCE WITH TCTO 1C-130-1515. ONE TIME INSPECTION OF THE NACELLE HORSE COLLAR AREA AND DRY BAY DRAINS AND DRAIN LINES FOR OBSTRUCTION.

REF: 1C-130-1515

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HVTCTO151500076B 100, 00116B 100C130H, 11000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26769ACCOMPLISH TCTO 1C-130-2029. INSPECTION OF LOWER ENGINE TRUSS MOUNTS FOR DEFECTIVE BARREL NUTS. SEE ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS. IAW TCTO 1C-130-2029.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY602INSPECT HVTCTO202900076B 100, 00116B 100C130H, 11000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71380**DONOR WING** (#2 TANK) INSTALL BRACES, ACCESS DOORS, & CLOSE TANK OPENINGS FOR TRANSPORT OF WING TO CMXG FACILITY.

REF:1C-130H-2-28JG-00-1;1C-130A-3.

OBSERVE ALL NOTES,CAUTIONS & WARNING. CLEAN AREA.

1C-130-2-WA-2 FOR IMIS TECH DATAN604INSTALL HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46110, 800, Q, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71389**DONOR WING** VISUALLY INSPECT THE LEFT OUTER WING TRAILING EDGE SKINS, SKIN PANEL ASSEMBLIES AND PANS FOR CRACKS, CORROSION AND GENERAL CONDITION.

REF. T.O 1C-130A-36, 1C-130A-3, 1C-130A-23, & 1-1A-8.

OBSERVE ALL NOTES CAUTIONS & WARNINGS. 1C-130-2-WA-2 FOR IMIS TECH DATAN602INSPECT HVLWGSWAPPRP00076B 100, 00116B 100C130H, 1171K, 799, X, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71388**DONOR WING** VISUALLY INSPECT THE LEFT OUTER WING FLAP WELL FOR CORROSION AND DETERIORATED FINISH.

REF 1C-130A-36, SECT II, 1C-130A-3, 1C-130A-23, 1-1A-8.

OBSERVE WARNINGS, CAUTIONS & NOTES. 1C-130-2-WA-2 FOR IMIS TECH DATAN602INSPECT HVLWGSWAPPRP00076B 100, 00116B 100C130H, 1152Q, 799, X, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E78511(#1 TANK) REMOVE AND DISCARD FOAM BAFFLES

FROM B,C,D,&E PANELS

(DEF GUIDE ATTACHED)

IAW:1C-130H-2-28JG-00-1

OBSERVE WARNINGS, CAUTIONS & NOTES.

CK FOR FO AND CLEAN AREA

IAW: 1C-130-2-WA-2 FOR IMIS TECH DATAY601ACCESS HVUSFSFOAM00076B 100, 00116B 100C130H, 46812, 800, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E78501(#4 TANK) REMOVE AND DISCARD FOAM BAFFLES

FROM "A" PANEL (DOG HOUSE)

IAW:1C-130H-2-28JG-00-1

OBSERVE WARNINGS, CAUTIONS & NOTES.

CK FOR FO AND CLEAN AREA

IAW: 1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVUSFSFOAM00076B 100, 00116B 100C130H, 46812, 800, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71411***INCOMING WING***

REMOVE BLEED AIR SYSTEM FROM LT WING TO SATISFY OUTER WING SWAP. REF: 1C-130H-2-21JG-10-1 AND 1C-130H-2-00GE-00-1. OBSERVE ALL NOTES, CAUTIONS, AND WARNINGS. CAP ALL OPEN LINES AND HOSES.

SEE ATTACHED DEF GUIDE.

1C-130-2-WA-2 FOR IMIS TECH DATAY601ACCESS HVSALVGINCOM00076B 100, 00116B 100C130H, 41AC0, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71417***INCOMING WING***

(#1 TANK) REMOVE 5 FUEL PROBES & 1 COMPENSATOR

REF 1C-130H-2-28JG-40-1. OBSERVE ALL WARNINGS, CAUTIONS & NOTES.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVSALVGINCOM00076B 100, 00116B 100C130H, 4663D, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71050(#4 TANK) VISUALLY INSPECT TANK FOR CRACKS, CORROSION, LOOSE OR CORRODED FASTENERS, AND SEALANT CONDITION

REF: 1C-130H-2-00GE-00-1, SECTION 5-16.5 THRU 5-16.10) AND

1-1-3, SECTION 6.5.3.,

CK FOR FO AND CLEAN AREA

IAW 1C-130-2-WA-2 FOR IMIS TECH DATAN602INSPECT HVRTWGOVERHL00076B 100, 00116B 100C130H, 46110, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71578REMOVE SEALANT,AND CLEAN AREA FROM # 2 TANK FORWARD LOWER SPAR CAP AT OWS 70/92 AS REQUIRED FOR NDI OW-39 LT SIDE INSPECTION, REF: 1C-130A-36,1-1-691.
OBSERVE ALL CAUTIONS, NOTES AND WARNING. 1C-130-2-WA-2 FOR IMIS TECH DATAN611SUPPORT OPSLWGSWAPPRP00076B 100, 00116B 100C130H, 1151U, 799, V, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71052(OW-52) REMOVE ALL SEALANT AND LOOSE PAINT FROM THE

LEFT WING INSPECTION AREA.

IAW:1C-130A-36 & 1C-130A-23

(IAW 1C-130-2-WA-2 FOR IMIS TECH DATA)

OBSERVE ALL WARNINGS, CAUTIONS & NOTES.N611SUPPORT OPSLWGSWAPPRP00076B 100, 00116B 100C130H, 115B0, 799, V, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E273MASK ACFT AS REQUIRED FOR US FORESTRY SERVICE PAINT SCHEME. REF: USCG DRAWINGS 300-14-2 AND 300-14-3. OBSERVE ALL WARNINGS, CAUTIONS, AND NOTES.

*** USFS ACFT 86-0422 IAW 202: C130-16-12645***

*** USFS ACFT 83-0505 IAW 202: C130-16-12647***N610PAINT OPSUSFSPAINT00076B 100C130H, 09000, , ,The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26761PREP ACFT FOR ACCOMPLISHMENT OF TCTO HC-130H-T54110. MODIFICATION OF C130 ENGINE TRUSS MOUNT DIAGONAL BRACE ATTACHMENT LUGS. IAW TCTO HC-130H-T54110. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS.

COAST GUARD WILL PERFORM THE MODIFICATION.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

SEE ATTACHED DEF GUIDEY602INSPECT HVT5411000076B 100, 00116B 100C130H, 01000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71275**DONOR WING** (#1 TANK) REMOVE #1 TANK INBOARD (1ST CAVITY) SURGE BOX TOP PANEL. BAG, TAG AND STORE PARTS.

REF: 1-1A-8 PARA 3.1.36.

OBSERVE ALL NOTES, CAUTIONS & WARNINGS.

CLEAN AREA.

N601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46113, 799, Q, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71276**DONOR WING** (#1 TANK) REMOVE ENGINE FUEL FEED LINE , 1ST CAVITY, FOR ACCESS. BAG, TAG AND STORE PARTS

IAW:1C-130H-2-28JG-00-1, 28-00-22.

OBSERVE ALL NOTES, CAUTIONS & WARNINGS. CLEAN AREA.

IAW 1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46299, 799, Q, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71519***DONOR WING***

INSTALL LEFT WING LEADING EDGE WHICH ENCOMPASSES LANDING LIGHT TO SATISFY OUTER WING SWAP PER ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS.

1C-130-2-WA-2 FOR IMIS TECH DATAY604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 44120, 800, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71520***DONOR WING***

INSTALL RIGHT WING LEADING EDGE WHICH ENCOMPASSES LANDING LIGHT TO SATISFY OUTER WING SWAP PER ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS.

1C-130-2-WA-2 FOR IMIS TECH DATAY604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 44120, 800, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71521***DONOR WING***

INSTALL FIRE EXTINGUISHER COMPONENTS TO SATISFY LT OUTER WING SWAP. SEE ATTACHED DEF GUIDE. REF: 1C-130H-2-00GE-00-1, 1C-130H-2-26GS-00-1, AND 1C-130H-2-26JG-20-1. OBSERVE ALL WARNINGS, NOTES, AND CAUTIONS.

1C-130-2-WA-2 FOR IMIS TECH DATA

Y604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 49000, 799, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71522***DONOR WING***

INSTALL FIRE EXTINGUISHER COMPONENTS TO SATISFY RT OUTER WING SWAP. SEE ATTACHED DEF GUIDE. REF: 1C-130H-2-00GE-00-1, 1C-130H-2-26GS-00-1, AND 1C-130H-2-26JG-20-1. OBSERVE ALL WARNINGS, NOTES, AND CAUTIONS.

1C-130-2-WA-2 FOR IMIS TECH DATA

Y604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 49000, 799, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71524***DONOR WING***

INSTALL BLEED AIR SYSTEM ON LT WING TO SATISFY OUTER WING SWAP. REF: 1C-130H-2-21JG-10-1 AND 1C-130H-2-00GE-00-1. OBSERVE ALL NOTES, CAUTIONS, AND WARNINGS. CAP ALL OPEN LINES AND HOSES.

SEE ATTACHED DEF GUIDE.

1C-130-2-WA-2 FOR IMIS TECH DATAY604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 41AC0, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71525***DONOR WING***

INSTALL BLEED AIR SYSTEM ON RT WING TO SATISFY OUTER WING SWAP. REF: 1C-130H-2-21JG-10-1 AND 1C-130H-2-00GE-00-1. OBSERVE ALL NOTES, CAUTIONS, AND WARNINGS. CAP ALL OPEN LINES AND HOSES.

SEE ATTACHED DEF GUIDE.

1C-130-2-WA-2 FOR IMIS TECH DATAY604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 41AC0, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71439***INCOMING WING***

REMOVE HYD HOSES AND ASSOCIATED HARDWARE FROM #4 HORSE COLLAR TO SATISFY OUTER WING SWAP. CAP ALL OPEN LINES. REF: 42E1-1-1. OBSERVE ALL WARNINGS, CAUTIONS, AND NOTES.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVSALVGINCOM00076B 100, 00116B 100C130H, 45000, 799, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71440***INCOMING WING***

REMOVE FUEL HOSE AND ASSOCIATED HARDWARE FROM #1 HORSE COLLAR TO SATISFY OUTER WING SWAP. CAP ALL OPEN LINES. REF: 42E1-1-1. OBSERVE ALL WARNINGS, CAUTIONS, AND NOTES.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVSALVGINCOM00076B 100, 00116B 100C130H, 46000, 799, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71441***INCOMING WING***

REMOVE FUEL HOSE AND ASSOCIATED HARDWARE FROM #4 HORSE COLLAR TO SATISFY OUTER WING SWAP. CAP ALL OPEN LINES. REF: 42E1-1-1. OBSERVE ALL WARNINGS, CAUTIONS, AND NOTES.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVSALVGINCOM00076B 100, 00116B 100C130H, 46000, 799, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71442***INCOMING WING***

REMOVE LT WING TIP.

REF:1C-130H-2-51JG-00-1. 51-20-02. OBSERVE ALL NOTES, CAUTIONS, & WARNINGS. CLEAN AREA.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVSALVGINCOM00076B 100, 00116B 100C130H, 1151J, 800, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71315**DONOR WING** (LEFT WING) SWING SHIFT, PERFORM EXPLOSIVE METER CHECK OF ALL OPEN TANKS WHILE IN MODDOCK.

RECORD READINGS IN DEF GUIDE.

REF: TO 1-1-3. SEE DEF GUIDE ATTACHEDY602INSPECT HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46110, 799, X, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71316**DONOR WING** (#1 TANK) VISUALLY INSPECT #1 FUEL TANK INTERIOR FOR EVIDENCE OF LOOSE POLYURETHANE CHIPS OR PEELING POLYURETHANE IAW TO 1C-130H-2-00GE-00-1, SECTION 5-16. NOTIFY SCHEDULER WITH RESULTS.

OBSERVE NOTES, WARNINGS, CAUTIONS & COMPLY WITH RAG/F.O. INSP.

NOTE: SECONDARY PAC REQ'D

IAW 1C-130-2-WA-2 FOR IMIS TECH DATAN602INSPECT HVLWGSWAPPRP00076B 100, 00116B 100C130H, 11511, 799, X, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71320**DONOR WING** VISUALLY INSPECT #2 TANK INTERIOR FOR CORROSION OR DEFECTS IN STRUCTURE. DOCUMENT DISCREPANCIES. UNUSUAL FINDINGS (I.E. BENT/DEFORMED STRUCTURAL MEMBERS, SEVERE CORROSION, STANDING WATER, FUNGUS, ETC.) WILL BE DOCUMENTED AND BROUGHT TO THE ATTENTION OF ENGINEERING VIA THE AUTOMATED AFSC FORM 202 SYSTEM.
REF: 1C-130A-23.N602INSPECT HVLWGSWAPPRP00076B 100, 00116B 100C130H, 46110, 799, X, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71289**DONOR WING** TOW LEFT DONOR WING FROM STRIPPING AREA TO CMXG FACILITY (B149) FOR MODIFICATION AND SCHEDULED MANINTENANCE.
NO TECH DATA REQUIRED.N611SUPPORT OPSLWGSWAPPRP00076B 100, 00116B 100C130H, 01000, 799, X, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71511***DONOR WING***

INSTALL COMPONENTS NECESSARY TO SATISFY LT OUTER WING SWAP TO #2 TANK . SAFETY WIRE AND CHECK AREA FOR F.O.

REF: 1C-130H-2-28JG-00-1; 1-1-3

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 46100, 804, T,The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71512***DONOR WING***

INSTALL COMPONENTS NECESSARY TO SATISFY RT OUTER WING SWAP FOR #3 TANK . CAP ALL OPEN LINES AND PLUGS AFTER REMOVAL.

REF: 1C-130H-2-28JG-00-1; 1-1-3Y604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 46100, 804, T,The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71513***DONOR WING***

INSTALL COMPONENTS NECESSARY TO SATISFY RT OUTER WING SWAP TO #4 TANK AND DRY BAY. CAP ALL OPEN LINES AND PLUGS AFTER REMOVAL. REF: 1C-130H-2-28JG-00-1; 1-1-3.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA.Y604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 46100, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71515**DONOR WING**

THIS OPERATION PRODUCES A DEFINITIZED GUIDE

FOR INSTALLATION OF THROTTLE AND CONDITION CABLES

FOR LEFT AND RIGHT DONOR OUTER WINGS. IAW: 1C-130H-2-76JG-00-1. OBSERVE ALL NOTE, WARNINGS, AND CAUTIONS.

IAW 1C-130-2-WA-2 FOR IMIS TECH DATA

**IF CABLES ARE REPLACED AFTO 95 ENTRY REQUIRED**Y604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 22EAQ, 921, G, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71516***DONOR WING***

INSTALL AILERON PUSH PULL RODS AND BELLCRANKS FROM LEFT OUTER WING TRAILING EDGE TO SATISFY OUTER WING SWAP. INSPECT FOR EXCESS WEAR

IAW: 1C-130H-2-27JG-10-1. OBSERVE ALL NOTES, CAUTIONS AND WARNINGS.

1C-130-2-WA-2 FOR IMIS TECH DATAN604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 14115, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71517***DONOR WING***

INSTALL AILERON PUSH PULL RODS AND BELLCRANKS FROM RIGHT OUTER WING TRAILING EDGE TO SATISFY OUTER WING SWAP. INSPECT FOR EXCESS WEAR

IAW: 1C-130H-2-27JG-10-1. OBSERVE ALL NOTES, CAUTIONS AND WARNINGS.

1C-130-2-WA-2 FOR IMIS TECH DATAN604INSTALL HVSALVGINSTL00076B 100, 00116B 100C130H, 14115, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E779TERMINATE WIRING AT GROUND STUD.

FS: 245.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7 STEP: TT

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E780PERFORM CONTINUITY ON MAFFS WIRING.

FS: 245.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7 STEPS: UU THRU XX

SECONDARY PAC REQUIRED

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E781REINSTALL CONTACTOR COVERS AFT FS 245

PREVIOUSLY REMOVED FOR MAFFS MOD

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7 STEP: YY

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E782PERFORM GROUND CHECK ON MAFFS WIRING.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7 STEP: ZZ

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E783PERFORM CLOSING INSPECTION &

REINSTALL PANELS AFT FS 245.

PREVIOUSLY REMOVED FOR MAFFS MOD

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7 STEP: AAA

REF: AMXG-06-235-075 FOR CLOSING INSP

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E784PERFORM OPERATIONAL CHECKOUT OF ENGINE GENERATOR

IN SUPPORT OF MAFFS MODIFICATION.

IAW: 1C-130H-2-24JG-20-1-1; 24-20-04.

REF: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 8; STEP A

SECONDARY PAC REQUIRED

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E785CONFIRMATION ONLY <><> TCTO 1C-130-2059 <><>

REWIRING OF THE MILITARY AIRBORNE FIRE FIGHTING SYSTEM

(MAFFS) BREAKOUT PANEL ON SELECTED C-130 AIRCRAFT

DATA CODE: 0122130

TCTO DATE: 12 OCTOBER 2010

RECISSION DATE: 12 OCTOBER 2013

AFTO 95 ENTRY REQUIRED

1C-130-2-WA-2 FOR IMIS TECH DATAN611SUPPORT OPSTCTO198200076B 100, 00116B 100C130H, 95000, 799, Q, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E787UPDATE WEIGHT AND BALANCE FOR THE INSTALLATION

OF MAFFS II PANEL.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 8 STEP B

OBSERVE ALL NOTES, CAUTIONS, AND WARNINGS.

2 PAC STAMPS REQUIRED. IAW 1C-130-2-WA-2 FOR IMIS TECH DATAN608OUTGOING HVTCTO198200076B 100, 00116B 100C130E, 04150, , , ; C130H, 04150, , , ; C130J, 04150, , , ; HC130N, 04150, , , ; HC130P, 04150, , , ; WC130H, 04150, , , ; WC130J, 04150, , ,The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E788GAIN ACCESS BY REMOVING DISTRIBUTION PANELS FS: 245

IAW: 1C-130-2059; PARA 6C

N601ACCESS HVTCTO205900076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E789PERFORM CONTINUITY CHECK TO DETERMINE CONFIGURATION.

IAW: 1C-130-2059; PARA 6D & E

HAVE PLANNER TRIGGER THE FOLLOWING OPS IF CONFIGURATION IS INCORRECT: 00785

SECONDARY PAC REQUIREDN605OPS CHECKTCTO205900076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E795REINSTALL PANELS AND RELAY COVERS REMOVED FOR

MAFFS MOD. FS: 245

REFERENCE DEF GUIDE FOR TECH DATAY604INSTALL HVTCTO205900076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71495***DONOR WING***

(#2 TANK) REMOVE 4 FUEL PROBES & 1 COMPENSATOR

REF 1C-130H-2-28JG-40-1 (28-41-14, 2-5). OBSERVE ALL WARNINGS, CAUTIONS & NOTES.

1C-130-2-WA-2 FOR IMIS TECH DATAN601ACCESS HVSALVGDONOR00076B 100, 00116B 100C130H, 4663D, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E78513(#2 TANK) REMOVE AND DISCARD FOAM BAFFLES

(DEF GUIDE ATTACHED)

IAW:1C-130H-2-28JG-00-1, 28-00-14

OBSERVE WARNINGS, CAUTIONS & NOTES.

CK FOR FO AND CLEAN AREA

IAW 1C-130-2-WA-2 FOR IMIS TECH DATAY601ACCESS HVUSFSFOAM00076B 100, 00116B 100C130H, 468A0, 800, P, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71583OW-61 RIGHT SIDE, REMOVE SEALANT AND CLEAN FOR NDI INSPECTION OW 61, REF: 1C-130A-36 PARA 4-637 / TO: 1-1-3, 1-1-691.
OBSERVE ALL CAUTIONS, NOTES AND WARNING. 1C-130-2-WA-2 FOR IMIS TECH DATAN611SUPPORT OPSRWGSWAPPRP00076B 100, 00116B 100C130H, 115BK, 799, V, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E71580OW-13 (#1 DRY BAY), REMOVE SEALANT AND CLEAN FOR NDI INSPECTION OW 13, ENGINE TRUSS TO RIB CAP ATTACH FITTINGS AND RIB CAPS OWS 162.78 AND OWS 197.13 REF: 1C-130A-36 PARA 4-319 PG 4-145 / TO: 1-1-3 1C-130-2-WA-2 FOR IMIS TECH DATAN611SUPPORT OPSLWGSWAPPRP00076B 100, 00116B 100C130H, 1154Y, 799, V, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26770CONFIRMATION OF COMPLIANCE WITH TCTO 1C-130-2029. INSPECTION OF LOWER ENGINE TRUSS MOUNTS FOR DEFECTIVE BARREL NUTS

REF: 1C-130-2029

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HVTCTO202900076B 100, 00116B 100C130H, 11000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26771ACCOMPLISH TCTO 1C-130-1573. REPLACEMENT OF STAINLESS STEEL BLEED AIR DUCTS WITH INCONEL DUCTS. SEE ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS. IAW TCTO 1C-130-1573.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY602INSPECT HVTCTO157300076B 100, 00116B 100C130H, 22FAG, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26772CONFIRMATION OF COMPLIANCE WITH TCTO 1C-130-1573. REPLACEMENT OF STAINLESS STEEL BLEDD AIR DUCTS WITH INCONEL DUCTS. REF: 1C-130-1573

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HVTCTO157300076B 100, 00116B 100C130H, 11000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26773ACCOMPLISH TCTO 1C-130-1578/1578C. ONE TIME INSPECTION OF ACFT LEADING EDGE WIRING HARNESS ASSEMBLY FOR CORRECT MILSPEC SHIELDED WIRING. SEE ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS. IAW TCTO 1C-130-1578/1578C.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY602INSPECT HVTCTO157800076B 100, 00116B 100C130H, 01000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26774CONFIRMATION OF COMPLIANCE WITH TCTO 1C-130-1578/1578C. ONE TIME INSPECTION OF AIRCRAFT LEADING EDGE WIRING HARNESS ASSEMBLY FOR CORRECT MILSPEC SHIELDED WIRING.

REF: 1C-130-1578/1578C

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HVTCTO157800076B 100, 00116B 100C130H, 11000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E55376**DONOR WING** COMPLY WITH TCTO 1C-130-1826 RIGHT WING

IAW ATTACHED DEFINITIZED GUIDE

CLEAN FOD CHECK AREA

OBSERVE ALL NOTES, CAUTIONS AND WARNINGS.

REF: 1-1A-8

NOTE: IF TCTO HAS RESCINDED SUBMIT 202 FOR AUTHORIZATION.

Y602INSPECT HVRTWGOVERHL00076B 100, 00116B 100C130H, 14413, 800, S, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E55392**DONOR WING** CONFIRMATION ONLY, COMPLIANCE WITH TCTO 1C-130-1826, "INSPECTION AND COLD WORK OF HOLES IN FLAP TRACK RIB ATTACH TEE AT FLAP STA 28.17"

RIGHT SIDE: DEF GUIDE #75376

LEFT SIDE: DEF GUIDE #75375

DATA CODE: 0192420

AFTO 95 ENTRY REQUIRED

NOTE: IF TCTO HAS RESCINDED SUBMIT 202 FOR AUTHORIZATION.

N602INSPECT HVLTWGOVERHL RTWGOVERHL00076B 100, 00116B 100C130H, 14413, 799, X, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E55398**DONOR WING** LEFT WING, COMPLY WITH REQUIREMENTS OF DEF GUIDE 55375 (TCTO 1C-130-1826, "INSPECTION AND COLD WORK OF HOLES IN RIB ATTACH TEE AT FLAP STA 28.17")

NOTE: IF TCTO HAS RESCINDED SUBMIT 202 FOR AUTHORIZATION.

N602INSPECT HVLTWGOVERHL00076B 100, 00116B 100C130H, 11500, 425, R, S;The work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26775ACCOMPLISH TCTO 1C-130-2099/2099C. WING JOINT COVER INSPECTION. SEE ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS. IAW TCTO 1C-130-2099/2099C.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY602INSPECT HVTCTO209900076B 100, 00116B 100C130H, 01000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26776CONFIRMATION OF COMPLIANCE WITH TCTO 1C-130-2099/2099C. WING JOINT COVER INSPECTION.

REF: 1C-130-2099/2099C.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA.

AFTO 95 ENTRY REQUIREDN602INSPECT HVTCTO209900076B 100, 00116B 100C130H, 11000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26777ACCOMPLISH TCTO 1C-130-1752. REPLACEMENT OF C-130 AIRCRAFT ENGINE TRUSS MOUNTS. SEE ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS. IAW TCTO 1C-130-1752.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY602INSPECT HVTCTO175200076B 100, 00116B 100C130H, 01000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26778CONFIRMATION OF COMPLIANCE WITH TCTO 1C-130-1752. REPLACEMENT OF C-130 AIRCRAFT ENGINE TRUSS MOUNTS. REF: 1C-130-1752.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HVTCTO175200076B 100, 00116B 100C130H, 01000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26779ACCOMPLISH TCTO 1C-130-2020. INSPECTION OF LOWER ENGINE MOUNT BARREL NUTS. SEE ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS. IAW TCTO 1C-130-2020.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

Y602INSPECT HVTCTO202000076B 100, 00116B 100C130H, 01000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26780CONFIRMATION OF COMPLIANCE WITH TCTO 1C-130-2020/2020C. INSPECTION OF LOWER ENGINE MOUNT BARREL NUTS. REF: 1C-130-2020/2020C.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HVTCTO202000076B 100, 00116B 100C130H, 01000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26781ACCOMPLISH TCTO 1C-130-1994. INSPECTION OF UPPER ENGINE MOUNT BOLTS. SEE ATTACHED DEF GUIDE. OBSERVE ALL NOTES, WARNINGS, AND CAUTIONS. IAW TCTO 1C-130-1994.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATAY602INSPECT HVTCTO199400076B 100, 00116B 100C130H, 01000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E26782CONFIRMATION OF COMPLIANCE WITH TCTO 1C-130-1994. INSPECTION OF UPPER ENGINE MOUNT BOLTS. REF: 1C-130-1994.

NOTE: IF TCTO HAS RESCINDED INPUT A 202 FOR AUTHORIZATION.

REF: 1C-130-2-WA-2 FOR IMIS TECH DATA

AFTO 95 ENTRY REQUIREDN602INSPECT HVTCTO199400076B 100, 00116B 100C130H, 01000, 799, X, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E758CONFIRMATION ONLY <><> TCTO 1C-130-2059 <><>

REWIRING OF THE MILITARY AIRBORNE FIRE FIGHTING SYSTEM

(MAFFS) BREAKOUT PANEL ON SELECTED C-130 AIRCRAFT.

DATA CODE: 0122130

TCTO DATE: 12 OCTOBER 2010

RECISSION DATE: 12 OCTOBER 2013.

AFTO 95 ENTRY REQUIREDN611SUPPORT OPSTCTO198200076B 100, 00116B 100C130H, 95000, 799, Q, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E763LABEL/BUILD UP WIRES FOR MAFFS MOD.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7; STEPS: C-N

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E764REMOVE PANELS AFT FS 245.

IAW: 202# C-130-15-01004, MAFFS TCTO USCGT DRAFT ATTACHMENT: PARA 7; STEP: P

* OBSERVE ALL WARNINGS, CAUTIONS AND NOTES. CLEAN AREA.

* 1C-130-2-WA-2 FOR IMIS TECH DATAN604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E765REMOVE CONTACTOR COVERS AFT FS 245.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7; STEP: Q

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E767DRILL HOLES AND INSTALL DOUBLERS/GROMMETS IN SUPPORT OF MAFFS WIRING, AT FS 245.

IAW: 202# C-130-15-01004, MAFFS TCTO USCGT DRAFT ATTACHMENT: PARA 7; STEPS: R-T. REF DEF GUIDE FOR DOCUMENTATION

* OBSERVE ALL WARNINGS, CAUTIONS AND NOTES. CLEAN AREA.

* 1C-130-2-WA-2 FOR IMIS TECH DATAY604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 11000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E768INSTALL GROUNDING STUD.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7; STEP: T.

FS: 245; W.L. 228

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E769INSTALL CONNECTORS ON MAFFS PANEL

FS:245.

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7; STEP: U & REF DWG: 200714441

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.

N604INSTALL HVTCTO198200076B 100, 00116B 100C130H, 95000, 801, N, SThe work cards are considered Government Purpose Rights data as defined in DFARS 252.227-7013.
HV99E772ROUTE, CLAMP & SECURE MAFFS WIRING

FROM MAFFS BREAKOUT BOX CONNECTORS

TO MAIN AC PANEL AREA AT FS: 245

IAW: 202# C-130-15-01004,

MAFFS TCTO USCGT DRAFT ATTACHMENT:

PARA 7; STEP: V-GG

CLEAN AREA.

OBSERVE ALL WARNINGS, CAUTIONS AND NOTES.