ASHE_12-1039_CCEB_Rev.01.xls

XLS spreadsheet 1 MB Posted

Attached to
ASHE 12-1039 Renovate Bldg 1469 for Community Center, Area F, Aviano AB, Italy
Solicitation number
FA568219RA002
Issued by

About this file

CCEB REV 1

View the file

Other files

File Type Posted
ATTACHMENT_4_REV.1.pdf PDF
FA568219RA0020004.pdf PDF
FA568219RA002_RFIs_Q_&_A_(5).pdf PDF
FA568219RA19RA002_RFIs_Q_&_A_(4).pdf PDF
FA568219RA19RA002_RFIs_Q_&_A_(2)_REV.1.pdf PDF
FA568219RA19RA002_RFIs_Q_&_A_(1).pdf PDF
FA568219RA19RA002_RFIs_Q_&_A_(3).pdf PDF
ASHE12~3.PDF PDF
ASHE12~2.PDF PDF
ASHE12~1.PDF PDF
F6B57A99.PDF PDF
SOVRIN~4.PDF PDF
SOVRIN~3.PDF PDF
SOVRIN~1.PDF PDF
ASHE12~2.PDF PDF
SOVRIN~2.PDF PDF
ASHE12~4.PDF PDF
7E8D02FB.PDF PDF
ASHE12~3.PDF PDF
E02E9BD8.PDF PDF
ASHE12~4.PDF PDF
ASHE12~1.PDF PDF
ASHE12~1.PDF PDF
ASHE12~2.PDF PDF
FA568219RA0020003.pdf PDF
ASHE_12-1039_SEP-2018_Tech_Specs_Rev.2.pdf PDF
REV_1-_Drawings_Pack_1.zip ZIP file
REV_1-Drawings_Pack_3.zip ZIP file
REV_1-Drawings_Pack_2.zip ZIP file
Solicitation_Amendment_FA568219RA0020002_SF_30.pdf PDF
Solicitation_Amendment_FA568219RA0020001_SF_30_-1.pdf PDF
Solicitation_-_FA568219RA002_Final.pdf PDF
AUTORI~1.PDF PDF
COMMDA~1.PDF PDF
ASHE_12-1039_CCEB_SEP-2018.xls XLS spreadsheet
ASHE_12-1039_ATTACHMENT_1.pdf PDF
ASHE_12-1039_SEP-2018_DWG.pdf PDF
Comment_Matrix_for_new_Comm_Requirements_ATTACHMENT_3.docx DOCX document
Design_Comments_ATTACHMENT_4.doc DOC document
ASHE_12-1039_SEP-2018_Tech_Specs_Rev.1.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

new cnstr.

CONSTRUCTION COST ESTIMATE BREAKDOWN - REV.01
CONTRACTORADDRESS
CONTRACT FOR (Work to be performed)PROPOSED TOTAL CONTRACT PRICE
RENOVATE FAC 1469 - AREA F- AVIANO AIR BASE
PURCHASE REQUEST NUMBERPROJECT NUMBERWORK LOCATION
ASHE 12-1039AREA F, AVIANO AIR BASE, ITALY
MATERIAL COSTSLABOR COSTS
LINE NO.ITEMUNIT OF MEASUREQUANTITYUNITTOTALMANHOURS MANDAYSAVERAGE RATETOTALOTHER DIRECT COSTSLINE TOTAL
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
A.NEW CONSTRUCTION / Nuova Costruzione
DESIGN REQUIREMENTS/Progettazione
0A/E services as per ASHE 12-1039 ATTACHMENT#1IT. No. Art. n.D1LA/AC
Total Design Requirement - Totale Progettazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS / Parte I - Demolizioni, Scavi e Rimozioni
Ia Architectural Work - Ia Lavori Architettonici
NOT APPLICABLE

Non Applicabile

Total Architectural Work - Totale Lavori Architettonici
Ib Structural Work - Ib Lavori Strutturali
1EXCAVATION IN ALL TYPE OF SOILS TO PROVIDE FOR STEEL SAFETY STAIRS, REINFORCED CONCRETE RAMPS FOR HANDICAPPED AND ADDITION BOILER ROOM
SCAVO DI TERRENO DI QUALSIASI NATURA E CONSISTENZA, PER LA FONDAZIONE DELLE SCALE DI SICUREZZA IN ACCIAIO, DELLE RAMPE PER DISABILI E AMPLIAMENTO LOCALE MACCHINEIT. No. Art. n.1mc
Total Structural Work - Totale Lavori Strutturali
Ic Civil Work - Ic Lavori Civili
NOT APPLICABLE

Non Applicabile

Total Civil Work - Totale Lavori Civili
Id Mechanical Work - Ic Lavori Meccanici
NOT APPLICABLE

Non Applicabile

Total Mechanical Work - Totale Lavori Meccanici
Ic Electrical Work - Ic Lavori Elettrici
NOT APPLICABLE

Non Applicabile

Total Electrical Work - Totale Lavori elettrici
TOTAL PART I - Totale Parte I
PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK / Parte II - Lavori Architettonici, Strutturali e Civili
IIa Architectural Work - IIa Lavori Architettonici
1MASONRY WALL -W5 TYPE
Pareti in mattoni doppio uni - tipo W5IT. No. Art. n.1mq
2GYPSUM BOARD PARTITIONS - W7 TYPE
Tramezzi in cartongesso- tipo W7IT. No. Art. n.2mq
3GYPSUM BOARD PARTITIONS - W13 TYPE
Tramezzi in cartongesso- tipo W13IT. No. Art. n.3mq
4HPL BOARD PARTITIONS - W12 TYPE
Tramezzi in HPL - tipo W12IT. No. Art. n.4mq
5GYPSUM BOARD PARTITIONS - W6 TYPE
Tramezzi in cartongesso- tipo W6IT. No. Art. n.5mq
6GYPSYUM VEILS
Velette in cartongessoIT. No. Art. n.6mq
7INTERNAL INSULATION 6 CM WITH GYPSIUM SHEET-THICKNESS 12mm
Isolamento interno di 6 cm con lastra in cartongesso spessore 12mm preaccoppiataIT. No. Art. n.7mq
8LIGHT OVERLOAD POLYSTIRENE FLOOR THERMAL INSULATION
Isolamento termico a sovraccarico leggeroIT. No. Art. n.8mq
9ROOF WATERPROOFING AND POLYSTIRENE THERMAL INSULATION
Isolamento termico in polistirene 8 cm + guaina bituminosaIT. No. Art. n.9mq
10ENTRANCE NATURAL MAT
zerbino di ingresso in materiale naturaleIT. No. Art. n.10Ea./No.
11REFRIGERED WATER COOLERS
beverini refrigeratiIT. No. Art. n.11Ea./No.
12CLASSROOM AND OFFICES DOORS ( 120 * 210 Cm) D10 -D2-D2W-D2WB
Porte delle aule E DEGLI UFFICI (160/90 * 210 cm) D10 -D2-D2W-D2WBIT. No. Art. n.12Ea./No.
13TOILETS DOORS (90 * 210 cm) D3 - D3h
Porte dei bagni ( (90*210 cm) D3 - D3hIT. No. Art. n.13Ea./No.
14ELECTRIC ELEVATOR and STAIR LIFT
Nuovo ascensore e servocalaIT. No. Art. n.14Ea./No.
15ENTRANCE COUNTER
bancone ingressoIT. No. Art. n.15Ls/Ac
16MOBILE WALL
parete mobileIT. No. Art. n.16Ls/Ac
17ARCHITECTURAL/CIVIL DESIGN CHANGES AS PER ATT #1,2,3,4
Modifiche Architettoniche/Civili coma da allegati 31,2,3,4IT. No. Art. n.17Ls/Ac
Total Architectural Work - Totale Lavori Architettonici
IIb Structural Work - IIb Lavori Strutturali
18METAL CARPENTRY S 235 GALVANIZED FOR SECURITY STAIR
Carpenteria metallica in acciaio S 235 zincato per scala di sicurezzaIT. No. Art. n.1kg
19METAL GRIL FLOOR GALVANIZED FOR SECURITY STAIR
Pavimento in grigliato metallico zincato per scala di sicurezzaIT. No. Art. n.2mq
20METAL STRUCTURE GALVANIZED FOR SECURITY STAIR
Struttura per parapetto in acciaio zincato per la scala di sicurezza e per copertureIT. No. Art. n.3kg
Total Structural Work - Totale Lavori Strutturali
IIc Civil Work - IIc Lavori Civili
NOT APPLICABLE

Non Applicabile

Total Civil Work - Totale Lavori Civili
TOTAL PART II / Totale Parte II
PART III - MECHANICAL WORK / Parte III - Lavori Meccanici
PART IIIa - HVAC SYSTEMS / Parte IIIa -Impianti HVAC
AIR DUCTS Canali dell'ariaIT. No. Art. n.1
28THICKNESS 21 mm
Spessore 21 mmIT. No. Art. n.1amq
29THICKNESS 30 mm
Spessore 30 mmIT. No. Art. n.1bmq
30INSULATED FLEXIBLE DUCTS
Canali flessibili isolatiIT. No. Art. n.2
31DIAMETER 102 mm
Diametro 102 mmIT. No. Art. n.2am
32DIAMETER 127 mm
Diametro 125 mmIT. No. Art. n.2bm
33DIAMETER 160 mm
Diametro 160 mmIT. No. Art. n.2cm
34DIAMETER 204 mm
Diametro 200 mmIT. No. Art. n.2dm
35DIAMETER 254 mm
Diametro 250 mmIT. No. Art. n.2em
36MEMBRANE FLOW REGULATOR
Regolatore di portata a membranaIT. No. Art. n.3
37SIZE 100 mm
Dimensione 100 mmIT. No. Art. n.3aEA/NO
38SIZE 125 mm
Dimensione 125 mmIT. No. Art. n.3bEA/NO
39SIZE 160 mm
Dimensione 160 mmIT. No. Art. n.3cEA/NO
40SIZE 200 mm
Dimensione 200 mmIT. No. Art. n.3dEA/NO
41SIZE 250 mm
Dimensione 250 mmIT. No. Art. n.3eEA/NO
42SILENCERS
SilenziatoreIT. No. Art. n.4
43SIZE 600x450x1200 mm
Dimensione 600x450x1200 mmIT. No. Art. n.4aEA/NO
44SIZE 900x450x1200 mm
Dimensione 900x450x1200 mmIT. No. Art. n.4bEA/NO
45LINEAR SLOT DIFFUSER
Diffusore lineareIT. No. Art. n.5
46SUPPLY 2 SLOTS LENGTH 6 m
Mandata 2 ferritoie lunghezza 6 mIT. No. Art. n.5aEA/NO
47RETURN 2 SLOTS LENGTH 6 m
Ripresa 2 ferritoie lunghezza 6 mIT. No. Art. n.5bEA/NO
48EXHAUST AIR VALVES
Valvole di estrazioneIT. No. Art. n.6
49DIAMETER 125 mm
Diametro 125 mmIT. No. Art. n.6aEA/NO
50DIAMETER 160 mm
Diametro 160 mmIT. No. Art. n.6bEA/NO
51SWIRL CIRCULAR DIFFUSERS
Diffusori circolariIT. No. Art. n.7
52DIAMETER 500 mm
Diametro 500 mmIT. No. Art. n.7aEA/NO
53DIAMETER 600 mm
Diametro 600 mmIT. No. Art. n.7bEA/NO
54SUPPLY AIR GRILLE
Griglia di mandataIT. No. Art. n.8LS/AC
55RETURN AIR GRILLE
Griglia di ripresaIT. No. Art. n.9LS/AC
56FRESH AIR HANDLING UNIT
Unità trattamento aria di rinnovoIT. No. Art. n.10
57TYPE NWA450F9 Modello NWA450F9IT. No. Art. n.10aEA/NO
58TYPE NWA750F9 Modello NWA750F9IT. No. Art. n.10bEA/NO
59VRV OUTDOOR AIR PROCESSING UNIT
Unità esterna VRVIT. No. Art. n.11EA/NO
60SLIM CEILING MOUNTED DUCT TYPE
Canalizzabile ultra piattaIT. No. Art. n.12
61TYPE FXDQ20
Modello FXDQ20IT. No. Art. n.12aEA/NO
62TYPE FXDQ32
Modello FXDQ32IT. No. Art. n.12bEA/NO
63TYPE FXDQ50
Modello FXDQ50IT. No. Art. n.12cEA/NO
64TYPE FXDQ63
Modello FXDQ63IT. No. Art. n.12dEA/NO
65CEILING MOUNTED DUCT TYPE
Canalizzabile media prevalenzaIT. No. Art. n.13
66TYPE FXSQ20
Modello FXSQ20IT. No. Art. n.13aEA/NO
67TYPE FXSQ25
Modello FXSQ25IT. No. Art. n.13bEA/NO
68TYPE FXSQ32
Modello FXSQ32IT. No. Art. n.13cEA/NO
69TYPE FXSQ50
Modello FXSQ50IT. No. Art. n.13dEA/NO
70ROUND FLOW CEILING MOUNTED CASSETTE TYPE
Cassette round flowIT. No. Art. n.14
71TYPE FXFQ40
Modello FXFQ40IT. No. Art. n.14aEA/NO
72MULTI FLOW CEILING MOUNTED CASSETTE TYPE
Cassette 4 vieIT. No. Art. n.15
73TYPE FXZQ15
Modello FXZQ15IT. No. Art. n.15aEA/NO
74TYPE FXZQ20
Modello FXZQ20IT. No. Art. n.15bEA/NO
75TYPE FXZQ25
Modello FXZQ25IT. No. Art. n.15cEA/NO
76INDIVIDUAL CONTROL SYSTEM
Pannello di comando a pareteIT. No. Art. n.16EA/NO
77CENTRALIZED CONTROL SYSTEM
Sistema di controllo centralizzatoIT. No. Art. n.17EA/NO
78REGULATION UNIT WITH SELECTOR VALVE
Unità di regolazione con valvola selettriceIT. No. Art. n.18
79TYPE BSVQ100
Modello BSVQ100IT. No. Art. n.18aEA/NO
80MULTI REGULATION UNIT WITH SELECTOR VALVE
Unità di regolazione con valvola selettrice multiplaIT. No. Art. n.19
81TYPE BSV4Q100
Modello BSV4Q100IT. No. Art. n.19aEA/NO
82TYPE BSV6Q100
Modello BSV6Q100IT. No. Art. n.19bEA/NO
83Y JOINT FOR OUTDOOR UNIT
Giunto a Y per unità esterneIT. No. Art. n.20EA/NO
84DERIVATION JOINT
Giunto di derivazioneIT. No. Art. n.21
85TYPE KHRQ22M20T
Modello KHRQ22M20TIT. No. Art. n.21aEA/NO
86TYPE KHRQ23M20T
Modello KHRQ23M20TIT. No. Art. n.21bEA/NO
87TYPE KHRQ23M29T9
Modello KHRQ23M29T9IT. No. Art. n.21cEA/NO
88TYPE KHRQ23M64T
Modello KHRQ23M64TIT. No. Art. n.21dEA/NO
89TYPE KHRQ23M75T
Modello KHRQ23M75TIT. No. Art. n.21eEA/NO
90CONDITIONING PREINSULATED COPPER PIPE
Tubazione in rame preisolata per condizionamentoIT. No. Art. n.22
91DIAMETER 6,4 mm
Diametro 6,4 mmIT. No. Art. n.22am
92DIAMETER 9,5 mm
Diametro 9,5 mmIT. No. Art. n.22bm
93DIAMETER 12,7 MM
Diametro 12,7 mmIT. No. Art. n.22cm
94DIAMETER 15,9 mm
Diametro 15,9 mmIT. No. Art. n.22dm
95DIAMETER 19,1 mm
Diametro 19,1 mmIT. No. Art. n.22em
96DIAMETER 22,2 mm
Diametro 22,2 mmIT. No. Art. n.22fm
97DIAMETER 28,6 mm
Diametro 28,6 mmIT. No. Art. n.22gm
98DIAMETER 34,9 mm
Diametro 34,9 mmIT. No. Art. n.22hm
99DIAMETER 41,3 mm
Diametro 41,3 mmIT. No. Art. n.22im
100COLUMN RADIATORS
Radiatori a colonnaIT. No. Art. n.23W
101THERMOSTATIC RADIATOR VALVE
Valvola termostaticaIT. No. Art. n.24
102DIAMETER DN 15
Diametro DN 15IT. No. Art. n.24aEA/NO
103RADIATOR AIR VENT AND DRAINAGE DEVICES
Valvolina di sfiatoIT. No. Art. n.25
104DIAMETER 1/4"
Diametro 1/4"IT. No. Art. n.25aEA/NO
Total HVAC Systems - Totale Impianti HVAC
PART IIIb - PLUMBING-FIRE EXTINGH.SYSTEM / PARTE IIIb - Impianto Idrico-sanitario e antincendio
NOT APPLICABLE

Non Applicabile

Total Plumbing System - Totale Impianto Idrico-Sanitario
PART IIIc - FIRE SYSTEM / Parte IIIc - Impianto antincendio
105SWINGING FIRE HOSE REEL
Naspo DN25IT. No. Art. n.1EA/NO
106PREPAINTED STEEL PIPES AND FITTINGS
Tubazione in acciaio preverniciatoIT. No. Art. n.2
107DIAMETER DN 25
Diametro DN 25IT. No. Art. n.2am
108DIAMETER DN 32
Diametro DN 32IT. No. Art. n.2bm
109DIAMETER DN 40
Diametro DN 40IT. No. Art. n.2cm
110DIAMETER DN 50
Diametro DN 50IT. No. Art. n.2dm
111BACKFLOW PREVENTER DN 50
Disconnettore DN 50IT. No. Art. n.3EA/NO
112PN 16 BALL VALVES AND FITTINGS
Valvole a sfera ed accessori PN 16IT. No. Art. n.4
113SIZE DN40 mm
Dimensione DN40 mmIT. No. Art. n.4aEA/NO
114SIZE DN50 mm
Dimensione DN50 mmIT. No. Art. n.4bEA/NO
Total fire system - Totale impianto antincendio
108PART IIId - GAS SYSTEM / Parte IIId - Impianto gas
109HDPE PIPES AND FITTINGS FOR GAS
Tubazioni in polietilene alta densità per gasIT. No. Art. n.1
110DIAMETER DN 32
Diametro DN 32IT. No. Art. n.1am
111DIAMETER DN 40
Diametro DN 40IT. No. Art. n.1bm
112DIAMETER DN 63
Diametro DN 63IT. No. Art. n.1cm
113COPPER PIPE
Tubazione in rameIT. No. Art. n.2
114DIAMETER 12x1 mm
Diametro 12x1 mmIT. No. Art. n.2am
115DIAMETER 16x1 mm
Diametro 16x1 mmIT. No. Art. n.2bm
116DIAMETER 28x1,5 mm
Diametro 28x1,5 mmIT. No. Art. n.2cm
117PN 16 BALL VALVES AND FITTINGS FOR GAS
Valvole a sfera ed accessori PN 16 per gasIT. No. Art. n.3
118SIZE DN15 mm
Dimensione DN15 mmIT. No. Art. n.3aEA/NO
119SIZE DN20 mm
Dimensione DN20 mmIT. No. Art. n.3bEA/NO
120Total GAS system - Totale impianto GAS
PART IIIe - MECHANICAL/PLUMBING/FIRE SYSTEM DESIGN CHANGES AS PER ATTACHMENTS #1,2,3,4
121MECHANICAL/PLUMBING/FIRE CHANGES AS PER ATT #1,2,3,4
Modifiche Meccaniche/Idro/Anti-Incendio come da allegati #1,2,3,4IT. No. Art. n.1LS/AC
Total MECHANICAL/PLUMBING/FIRE SYSTEM DESIGN CHANGES
TOTAL PART III / Totale Parte III
PART IV- ELECTRICAL WORK / Parte IV - Lavori Elettrici
122GROUNDING SYSTEM COPPER CONDUCTOR CORD 50mmq
Impianto di messa a terra in corda in rame 50mmqIT. No. Art. n.1m
123GROUNDING SYSTEM COPPER PLATED STEEL ROD D20 3m DEEP
Dispersore in acciaio ramato D20 prof 3mIT. No. Art. n.2EA/NO
124SOLID COPPER TRACER CABLE 3mm AND WARNING TAPE
cavo di rilevamento in rame da 3mm e nastro segnaleticoIT. No. Art. n.3m
125CONCRETE PIT 40X40 WITH CAST IRON COVER
Pozzetto in calcestruzzo 40x40 con chiusino in ghisaIT. No. Art. n.4aEA/NO
126CONCRETE PIT 50X50 WITH CAST IRON COVER
Pozzetto in calcestruzzo 50x50 con chiusino in ghisaIT. No. Art. n.4bEA/NO
127CONCRETE PIT 70X70 WITH CAST IRON COVER
Pozzetto in calcestruzzo 70x70 con chiusino in ghisaIT. No. Art. n.4cEA/NO
128BONDINGS WITH 6/10/16/25/35 sqmm CONDUCTOR
Collegamenti equipotenzializzazioni con conduttore 6/10/16/25/35mmqIT. No. Art. n.5LS/AC
129MAIN COPPER GROUNDING BAR
Barra principale di terraIT. No. Art. n.6EA/NO
130NEW MESHED AIR TERMINATION SOILD COPPER COND. 50mmq
Nuovo dispersore a maglia in corda piena di rame 50mmqIT. No. Art. n.7m
131150 cm AIR TERMINAL FOR MESHED LPS
Aste di captazione da 150cm per LPS a magliaIT. No. Art. n.8EA/NO
132300 cm MAST FOR CATENARY APPLICATION
Palo da 300 cm per applicazioni a catenariaIT. No. Art. n.9EA/NO
133AIR TERMINATION CONDUCTOR FOR CATENARY APPLICATION
Conduttore di captazione per applicazioni a catenariaIT. No. Art. n.10m
134DOWN CONDUCTOR CONNECTION, PROTECTION AND TAGGING
Collegamento, protezione e siglatura calata.IT. No. Art. n.11EA/NO
135ELECTRIC MASS BONDINGS NEAR DOWNLEADS AND ON ROOF
equipotenzializzazione corpi metallici presso le calate e coperturaIT. No. Art. n.12LS/AC
136PVC CABLE DUCT SYSTEM FOR OUTLET AND DATA DISTRIBUTION
Canale attrezzato in PVC per la distribuzione FM e datiIT. No. Art. n.13m
137ELECTRONIC PUSH BUTTON FOR LIGHT DOMOTIC UNITS
Pulsante elettronico per comando attuatore domoticoIT. No. Art. n.14EA/NO
138LIGHTING ACTIVATION SENSOR
Sensore di presenza per accensioni luciIT. No. Art. n.15EA/NO
13910A LIGHTING SWITCH NORMAL TYPE
Interruttore o deviatore 10A per luci normaleIT. No. Art. n.16aEA/NO
14010A LIGHTING SWITCH WP IP55 TYPE
Interruttore o deviatore 10A per luci IP55IT. No. Art. n.16bEA/NO
141LIGHT POINT ADDED
Punto luce aggiuntoIT. No. Art. n.16cEA/NO
142LIGHT POINT RELAY
Punto luce a rele'IT. No. Art. n.16dEA/NO
143OUTDOOR AREAS LIGHTING
Illuminazione aree esterneIT. No. Art. n.17LS/AC
144GENERATOR 200kVA
Gruppo elettrogeno 200kVAIT. No. Art. n.18EA/NO
145UPS WITH BATTERY CABINET 30kVA
UPS con armadio batterie 30kVAIT. No. Art. n.19EA/NO
146POWER FACTOR CORRECTION DEVICE 100kvar
Gruppo di rifasamento 100kvarIT. No. Art. n.20EA/NO
147LOCAL CABIN MT/BT IMPLEMENTATION / INTERFACE WORKS-164
Implementazioni e lavori presso la cabina MT/BT -1465IT. No. Art. n.21LS/AC
148DATA LAN OUTLET RJ45 TYPE CAT. 6
Presa RJ45 per reti dati cat. 6IT. No. Art. n.22EA/NO
149DATA CABLE UTP TYPE CAT. 6
Cavo dati tipo UTP cat. 6IT. No. Art. n.23m
150DATA RACK SET AND RELEVANT EQUIPMENT
Set di armadi permutatori con relativi componentiIT. No. Art. n.24LS/AC
151OPTIC FIBER AND COPPER FACILITY CONNECTION
Allacciamento edificio con fibra ottica e rameIT. No. Art. n.25LS/AC
152VIDEOPROJECTION SYSTEM KIT PROVISION
Predisposizione kit sistema di videoproiezioneIT. No. Art. n.26LS/AC
153TELEVISION SYSTEM DISTRIBUTION
Distribuzione TV del fabbricatoIT. No. Art. n.27LS/AC
154FIRE SECURITY SWITCH WITH CABLING
Sgancio di emergenza e cablaggioIT. No. Art. n.28EA/NO
155FIRE ALARM SYSTEM CENTRAL UNIT
Centrale di allarme incendiIT. No. Art. n.29EA/NO
156FIRE ALARM RADIO TRANSMITTER WITH ANTENNA Trasmettitore radio con antennaIT. No. Art. n.30LS/AC
157ANALOGUE FIRE ALARM SYSTEM SMOKE DETECTOR
Rivelatore di fumo di tipo analogicoIT. No. Art. n.31EA/NO
158ANALOGUE FIRE ALARM DUCT SMOKE DETECTOR
Rivelatore di fumo di tipo analogico per installazione entro condottaIT. No. Art. n.32EA/NO
159ANALOGUE FIRE ALARM HEAT DETECTOR
Rivelatore di calore di tipo analogicoIT. No. Art. n.33EA/NO
160LED AND BUZZER FOR SMOKE DETECTOR
Led e ronzatore per rivelatore di fumoIT. No. Art. n.34EA/NO
161ANALOGUE MANUAL FIRE ALARM STATION
Pulsante manuale attivazione impianto di rilevazioneIT. No. Art. n.35EA/NO
162AUDIO-VISUAL FIRE ALARM DEVICE
Dispositivo ottico acustico per impianto di rivelazione incendiIT. No. Art. n.36EA/NO
163VISUAL STROBOSCOPIC FIRE ALARM DEVICE
Dispositivo ottico stroboscopico per impianto di rivelazione incendiIT. No. Art. n.37EA/NO
164OUTDOOR AUDIO-VISUAL FIRE ALARM DEVICE WATERPROOF
Dispositivo ottico acustico esterno per impianto di rivelazione incendiIT. No. Art. n.38EA/NO
165FIRE ALARM SYSTEM EQUIPMENT CONNECTION
Collegamento equipaggiamenti all'impianto rivelazione incendiIT. No. Art. n.39LS/AC
166FIRE ALARM SYSTEM LOOP LINES
Linee impianto di rivelazione incendiIT. No. Art. n.40m
167GAS DETECTION SYSTEM KIT
Kit impianto di rivelazione gasIT. No. Art. n.41LS/AC
168SECURITY SOUND DIFFUSION SYSTEM
Impianto di diffusione sonora di sicurezzaIT. No. Art. n.42LS/AC
169GENERAL SYSTEM TEST
Test generale finaleIT. No. Art. n.43LS/AC
170ELECTRICAL CHANGES AS PER ATT #1,2,3,4
Modifiche Elettriche come da allegati #1,2,3,4IT. No. Art. n.44LS/AC
TOTAL PART IV / Totale Parte IV
DESIGN REQUIREMENTS
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS
PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK
PART III - MECHANICAL WORK
PART IV - ELECTRICAL WORK
TOTAL PRICE / Costo Totale

&C&12FOR OFFICIAL USE ONLY

&C&12 FOR OFFICIAL USE ONLY&RSheet &P of &N

&C&12FOR OFFICIAL USE ONLY

&C&12 FOR OFFICIAL USE ONLY&RSheet &P of &N

&C&12FOR OFFICIAL USE ONLY

&C&12 FOR OFFICIAL USE ONLY&RSheet &P of &N

&C&12FOR OFFICIAL USE ONLY

&C&12 FOR OFFICIAL USE ONLY&RSheet &P of &N

&C&12FOR OFFICIAL USE ONLY

&C&12 FOR OFFICIAL USE ONLY&RSheet &P of &N &C&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY &LAF Form 3052, JAN 88&CPREVIOUS EDITION IS OBSOLETE&"Arial,Grassetto"&12 FOR OFFICIAL USE ONLY&RSheet &P of &N &C&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY &LAF Form 3052, JAN 88&CPREVIOUS EDITION IS OBSOLETE&"Arial,Grassetto"&12 FOR OFFICIAL USE ONLY&RSheet &P of &N &C&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY &LAF Form 3052, JAN 88&CPREVIOUS EDITION IS OBSOLETE&"Arial,Grassetto"&12 FOR OFFICIAL USE ONLY&RSheet &P of &N &C&"Arial,Grassetto"&12FOR OFFICIAL USE ONLY &LAF Form 3052, JAN 88&CPREVIOUS EDITION IS OBSOLETE&"Arial,Grassetto"&12 FOR OFFICIAL USE ONLY&RSheet &P of &N

&C&12FOR OFFICIAL USE ONLY

&C&12 FOR OFFICIAL USE ONLY&RSheet &P of &N

&C&12FOR OFFICIAL USE ONLY

&C&12 FOR OFFICIAL USE ONLY&RSheet &P of &N repair

CONSTRUCTION COST ESTIMATE BREAKDOWN - REV.01
CONTRACTORADDRESS
CONTRACT FOR (Work to be performed)PROPOSED TOTAL CONTRACT PRICE
RENOVATE FAC 1469 - AREA F- AVIANO AIR BASE
PURCHASE REQUEST NUMBERPROJECT NUMBERWORK LOCATION
ASHE 12-1039AREA F, AVIANO AIR BASE, ITALY
MATERIAL COSTSLABOR COSTS
LINE NO.ITEMUNIT OF MEASUREQUANTITYUNITTOTALMANHOURS MANDAYSAVERAGE RATETOTALOTHER DIRECT COSTSLINE TOTAL
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
B.REPAIR WORK / Lavori di Ristrutturazione
PART I - DEMOLITIONS, EXCAVATIONS AND REMOVALS / Parte I - Demolizioni, Scavi e Rimozioni
Ia Architectural Work - Ia Lavori Architettonici
1INTERNAL AND EXTERNAL DOORS REMOVAL
RIMOZIONE DI PORTE SIA INTERNE CHE ESTERNEIT. No. Art. n.1mq
2INTERNAL AND EXTERNAL WINDOWS REMOVAL
RIMOZIONE DI SERRAMENTI SIA INTERNI CHE ESTERNIIT. No. Art. n.2mq
3DEMOLITION OF PARTITIONS AND GLAZING
DEMOLIZIONE DI TRAMEZZATURE E TAMPONAMENTIIT. No. Art. n.3mq
4CUT AND DEMOLITION OF EXISTING STAIR
TAGLIO E DEMOLIZIONE DELLA SCALA ESISTENTEIT. No. Art. n.4mc
5REMOVAL OF WOOD PARTITION AND WALL WAINSCOT
RIMOZIONE DI PARETE DIVISORIA DI LEGNO E DEI RIVESTIMENTI DI LEGNO DALLE PARETIIT. No. Art. n.5mq
6REMOVAL OF FLOORING, INCLUDING DEMOLITION OF COVE BASE AND SETTING BED 6cm
RIMOZIONE DI PAVIMENTI COMPRESO ZOCCOLINI E LA DEMOLIZIONE DEL MASSETTO DI POSA 6cmIT. No. Art. n.6mq
7REMOVAL OF CERAMIC WALL TILING
RIMOZIONE DI RIVESTIMENTO DI PIASTRELLE DI CERAMICA DALLE PARETIIT. No. Art. n.7mq
8REMOVAL OF BREASTWORKS AND METAL GUARDS
RIMOZIONE DI PARAPETTI E RINGHIERE DI METALLOIT. No. Art. n.8mq
9REMOVAL OF MEMBRANE WATERPROOFING FROM GROUND FLOOR
RIMOZIONE DEL MANTO DI IMPERMEABILIZZAZIONE DEI SOLAI DI COPERTURAIT. No. Art. n.9mq
10DEMOLITION OF ASBESTOS CEMENT STRUCTURES
DEMOLIZIONE DI MANUFATTI DI CEMENTO-AMIANTOIT. No. Art. n.10mc
11PLASTER AND WALLS COATING TO BE REMOVED
DEMOLIZIONE DI INTONACI E RIVESTIMENTI SU PARETI INTERNEIT. No. Art. n.11mq
12DEMOLITION OF PLASTER AND COATINGS ON EXTERNAL WALLS NOT IN STONE
DEMOLIZIONE DI INTONACI E RIVESTIMENTI SU PARETI ESTERNEIT. No. Art. n.12mq
13DEMOLITION OF PLASTERED SUSPENDED CEILING
DEMOLIZIONE DI CONTROSOFFITTOIT. No. Art. n.13mq
14REMOVAL OF GUTTERS
RIMOZIONE DI GRONDE E SIMILIIT. No. Art. n.14m
15REMOVAL OF GRIDS AND METAL FENCE
RIMOZIONE DI GRIGLIE E INFERRIATE IN ACCIAIOIT. No. Art. n.15mq
16REMOVAL OF PLASTERED SUSPENDED CEILING GYPSUM BOARDS, MINERAL FIBER
RIMOZIONE CONTROSOFFITTO IN PANNELLI DI GESSO, FIBRE MINERALIIT. No. Art. n.16mq
17CUT AND DEMOLITION OF EXISTING SLAB AT GROUND FLOOR INCLUDING FOUNDATION AND EARTH
TAGLIO E DEMOLIZIONE DELLA SOLETTA A TERRA ESISTENTE INCLUSO VESPAIO, E TERRENO SOTTOSTANTEIT. No. Art. n.17mc
18DEMOLITION OF GALVANIZED STEEL STRUCTURE AND COVER
DEMOLIZIONE TETTOIAIT. No. Art. n.18lump sum / corpo
19DEMOLITION OF EXISTING MASONRY WALLS FOR NEW DOOR AND WINDOW OPENINGS
DEMOLIZIONE DELLE MURATURE ESISTENTI PER L’APERTURA DI NUOVI VANI PORTA E FINESTREIT. No. Art. n.19mc
20DEMOLITION OF MASONRY AND/OR CONCRETE SHELVES IN VARIOUS ROOM
DEMOLIZIONE DELLE STRUTTURE IN MURATURA E/O CALCESTRUZZO DEGLI ARMADI NEI VARI LOCALIIT. No. Art. n.20mq
21FACILITY FLOORS DEEP CLEANING, INCLUDING PENGUION EXCREMENT REMOVAL AND DISPOSAL
SANIFICAZIONE DI TUTTI I PIANI, INCLUSO BONIFICA GUANO PICCIONIIT. No. Art. n.21lump sum / corpo
Total Architectural Work - Totale Lavori Architettonici
Ib Structural Work - Ib Lavori Strutturali
22DEMOLITION A STRUCTURAL MASONRY
DEMOLIZIONE MURATURA PORTANTEIT. No. Art. n.1mc
Total structural Work - Totale Lavori strutturali
Ic Civil Work - Ic Lavori Civili
23DEMOLITION OF 20 CM THICK, APPROX., BITUMINOUS CONCRETE PAVEMENT - DEMOLIZIONE DI PAVIMENTAZIONE IN CONGLOMERATO BITUMINOSO, SPESSORE CIRCA 20 CMIT. No. Art. n.1mq
24DEMOLITION OF CONCRETE PAVEMENTS AND PERIMETER SIDEWALKS PAVED WITH TILES
DEMOLIZIONE DI PAVIMENTAZIONI DI CONGLOMERATO CEMENTIZIO E MARCIAPIEDI PERIMETRALE PAVIMENTATO CON PIASTRELLE DI QUALSIASI TIPOIT. No. Art. n.2mq
25DEMOLITION OF BUILDING EXTERIOR CONCRETE LANDINGS, STEPS AND RAMPS, INCLUDING THE FOUNDATIONS
DEMOLIZIONE DEI PIANEROTTOLI, GRADINI E RAMPE IN CALCESTRUZZO ALL'ESTERNO DEL FABBRICATO, COMPRESE LE FONDAZIONIIT. No. Art. n.3mq
26ASBESTOS DOWNSPOUT TO BE REMOVED
PLUVIALE IN CEMENTO AMIANTO DA RIMUOVEREIT. No. Art. n.4m
27DEMOLITION OF METAL FENCE
DEMOLIZIONE GRATA METALLICA DI RECINZIONEIT. No. Art. n.5mq
Total Civil Work - Totale Lavori Civili
Id Mechanical Work- Id Lavori Meccanici
28REMOVAL OF EXISTING PLUMBING SYSTEM / Rimozione di sanitari, rubinetterie e tubazioni esistentiIT. No. Art. n.1lump sum / corpo
29REMOVAL OF EXISTING HVAC SYSTEM / Rimozione dell'impianto di HVAC esistenteIT. No. Art. n.2lump sum / corpo
30REMOVAL OF EXISTING PIPES AND VALVES ON MECHANICAL ROOM / Rimozione di tubazioni e valvole all'interno del locale impianti meccaniciIT. No. Art. n.3lump sum / corpo
Total Mechanical Work - Totale Lavori Meccanici
Ie Electrical Work - Ie Lavori Elettrici
31REMOVE AND DISPOSAL OF EXISTING EXTERNAL ELECTRICAL
Rimozione e smaltimento dell'impianto elettrico esterno esistenteIT. No. Art. n.1LS/AC
32REMOVE AND DISPOSAL OF EXISTING INTERNAL ELECTRICAL
Rimozione e smaltimento dell'impianto elettrico interno esistenteIT. No. Art. n.1LS/AC
Total Electrical Work - Totale Lavori Elettrici
TOTAL PART I - Totale Parte I
TOTAL PART I / Totale Parte I
PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK / Parte II - Lavori Architettonici, Strutturali e Civili
PART II - ARCHITECTURAL, STRUCTURAL AND CIVIL WORK / Parte II - Lavori Architettonici, Strutturali e Civili
IIa Architectural Work - IIa Lavori Architettonici
33SHEET WATERPROOFING
Impermeabilizzazione contro terraIT. No. Art. n.1mq
34CLOSURE OF NICHES, WITH CLAY BRICKS
Chiusura di vani e fori e nuove spallette in mattoni pieni o semipieniIT. No. Art. n.2mc
35CERAMIC TILE FOR BATHROOMS
Piastrelle in ceramica per bagniIT. No. Art. n.3mq
36EXTERIOR FIXED ALUMINIUM WINDOW
Serramento fisso in alluminio (Esterni)IT. No. Art. n.4mq
37INTERNAL CEILING PLASTER
Intonaco interno a soffittoIT. No. Art. n.5mq
38MINERAL FABER FALSE CEILING
Controsoffitti in fibra mineraleIT. No. Art. n.6mq
39STAINLESS STEEL HANDRAIL
Corrimano in acciaioIT. No. Art. n.7Kg
40PREFABRIC VIBRATED CONCRETE BOND BEAM ROAD Cordonata stradale prefabbricata in cls. vibrocompresso.IT. No. Art. n.8m
41SELFLOCKING MODULES CONCRETE FLOOR Pavimentazione in betonella compreso il sottofondo in sabbiaIT. No. Art. n.9mq
42LIME CEMENT BASED PREMIX FOR EXTERNAL TWO LAYERS PLASTER
Intonaco premiscelato per esterniIT. No. Art. n.10mq
43WASHABLE ANTIMOULD PAINT (exterior)
Idropittura lavabile (esterno)IT. No. Art. n.11mq
44PERVIUS EMULSION BASED ACRYLIC RESINS (internal) Idropitta traspirante a base di resine acriliche (internal)IT. No. Art. n.12mq
45RECOVERY FLOORING IN EXISTING PALLADIANA OR TERRAZZO
Ripristino pavimentazione esistente in Palladiana o TerrazzoIT. No. Art. n.13mq
46EXTERNAL METAL DOORS - D12 TYPE Porte esterne in metallo tipo D12IT. No. Art. n.14Ea./No.
47STAIRS GRES FLOOR INCLUDING BACKGROUND SLAB AND GRES BASEBOARD Pavimento delle scale in gres compreso sottofondo e battiscopaIT. No. Art. n.15mq
48CERAMIC PORCELAIN TILE FLOOR - F3 TYPE Pavimento in piastrelle di ceramica porcellanata - tipo F3IT. No. Art. n.16mq
49STONE BASEBOARD - THICKNESS 3 CM Zoccolino in pietra spessore tre cm ed impermeabilizzazioneIT. No. Art. n.17m
50EXTERNAL / INTERNAL METAL DOORS - D8 - D11 - D11R Porte esterne E INTERNE in metallo tipo D8 - D11 - D11RIT. No. Art. n.18Ea./No.
51EXTERNALS GLAZED DOORS ( 1 LIFT ) D6 TYPE Porte esterne vetrate 1 anta Tipo D6IT. No. Art. n.19Ea./No.
52SLAB FOR FORMATION OF SLOPES. SURCHARGE FOR EACH ADDITION
Caldana per formazione di pendenza. Sovraprezzo per ogni cm in più.IT. No. Art. n.20mq
53REPAIR EXISITING SYSTEM FOUNTAIN AND MASONRY ASSISTENCE Sistemazione impianto fontana esistente e assistenze murarieIT. No. Art. n.21Ls/Ac
54METAL DOORS WITH NO PANIC HANDLE AND GLASS FACADE D9 TYPE Clear opening 100 cm H(210+25)
Porte in metallo con maniglione antipanico e tamponamento in vetro - Tipo D9 Apertura netta 100 cm H(210+25)IT. No. Art. n.22Ea./No.
55STAINLESS STEEL DOWNSPOUT THICK. 8/10 MM - DIA 12 cm
Pluviali in acciaio inox spess 8/10 mm - diametro 12 cmIT. No. Art. n.23m
56STAINLESS STEEL END THICKNESS 8/10 mm DIA 12cm Terminali in acciaio inox spess 8/10 mm - diametro 12 cmIT. No. Art. n.24Ea./No.
57METAL DOORS WITH NO PANIC HANDLE AND GLASS FACADE D4 TYPE
Porte in metallo con maniglione antipanico e tamponamento in vetro - Tipo D4IT. No. Art. n.25Ea./No.
58EXTERNAL GLAZED DOORS ( 2 LIFT ) TYPE D7 clear opening 120 cm x H (210+25) Porte esterne vetrate 2 ante Tipo D7 apertura netta 120cm x H (210+25)IT. No. Art. n.26Ea./No.
59EXTERNAL METAL DOORS - D1 TYPE Porte esterne in metallo tipo D1IT. No. Art. n.27Ea./No.
60ENTRANCE DOOR LIKE EXSISTING Porta di ingresso come esistenteIT. No. Art. n.28Ea./No.
61STON AND MARBLE THERESOLDS Nuove soglie e davanzali in pietraIT. No. Art. n.29mq
62NEW REINFORCED CONCRETE LINTEL Nuove architravi in cementoIT. No. Art. n.30m
63REPLACE EXSISTING EXTERNAL BRICKS Ripristino di listelli faccia vista esistentiIT. No. Art. n.31mq
64ACCOMODATION STORMWATER SYSTEMS ON THE COVERAGE Sistemazione scarichi acque meteoriche in coperturaIT. No. Art. n.32Ea./No.
65NEW REFRACTARY CERAMIC CIMNEY Nuovo camino in materiale refrattario a base ceramicaIT. No. Art. n.33m
66BATROOM ACCESSORIES Accessori bagnoIT. No. Art. n.34Ls/Ac
67COATING COVERAGE CIMNEY AND ORIZONTAL CLOSING Rivestimento canna fumaria in copertura e chiusura orizzontaleIT. No. Art. n.35mq
68WOOD CHAIR RAIL paracolpi in legnoIT. No. Art. n.36m
69SISMIC JOINT giunto sisimicoIT. No. Art. n.37m
70SUPPORT KIT TO BASIN INSTALLED ON THE PLASTERBOARD WALL kit sostegno per lavabi su parete in cartongessoIT. No. Art. n.38Ea./No.
71SUPPORT KIT TO WC AND URINAL INSTALLED ON THE PLASTERBOARD WALL kit sospensione per wc e orinatoio su parete in cartongessoIT. No. Art. n.39Ea./No.
72CLEANIG, REPAIR EXTERNAL PERIMETER WALL pulizia e ripristino muretto perimetrale esternoIT. No. Art. n.40Ls/Ac
72ALL ACTIVITIES TO COMPLETE THE ACCESSORY LOCAL tutte le attività per completare il locale accessorioIT. No. Art. n.41Ls/Ac
73ROLLER BLIND Nuove TapparelleIT. No. Art. n.42mq
Total Architectural Work - Totale Lavori Architettonici
IIb Structural Work - IIb Lavori Strutturali
74SHORING OF VERTICAL STRUCTURE Puntellazione strutture verticaliIT. No. Art. n.1mq
75SHORING OF HORIZONTAL STRUCTURES Puntellazioni strutture orizzontaliIT. No. Art. n.2mq
76CONCRETE SLAB Massetto in getto di calcestruzzo, sp, 10 cmIT. No. Art. n.3mq
77DIRECT FOUNDATION OF REINFORCED CONCRETE Fondazioni dirette in getto di calcestruzzoIT. No. Art. n.4mc
78SUB-FOUNDATION OF REINFORCED CONCRETE Sottofondazioni dirette in getto di calcestruzzoIT. No. Art. n.5mc
79LEAN CONCRETE FOR FUNDATIONS AND PIPE PROTECTION Magrone in getto di calcestruzzo per fondazioni e calottatura tubazioniIT. No. Art. n.6mc
80REINFORCED CONCRETE WALL . Murature in elevazione in calcestruzzo armato. Spessore fino a 15 cmIT. No. Art. n.7mc
81REINFORCED CONCRETE WALL Murature in elevazione in calcestruzzo armato. Spessore fino da 15 a 30 cmIT. No. Art. n.8mc
82REINFORCED CONCRETE BEAMS Travi in getto di calcestruzzoIT. No. Art. n.9mc
83REINFORCED CONCRETE COLUMNS Pilastri in getto di calcestruzzoIT. No. Art. n.10mc
84REINFORCED CONCRETE SLABS Solette in getto di calcestruzzoIT. No. Art. n.11mc
85SMOOTH BOTTOM REINFORCED CONCRETE STAIR RAMP Scale in getto di calcestruzzoIT. No. Art. n.12mc
86STEEL CONCRETE REINFORCEMENT IN BARS NET PROTECTION TYPE FeB44k Armature di acciao per cementi armati in barre FeB44kIT. No. Art. n.13kg
87R.C. REINFORCED STEEL IN BARS OR WELDED MESH E FeB44k Armature di acciao per cementi armati in barre o rete elettrosaldata FeB44kIT. No. Art. n.14kg
88MASONRY REINFORCEMENT WITH STEEL MESH AND SHOTCRETE Rinforzo murature in laterizio con rete e betoncinoIT. No. Art. n.15mq
89MASONRY REINFORCED WITH R.C. SLABS Rinforzo murature in laterizio con lastra in c.a. da 10 cmIT. No. Art. n.16mq
90R.C. BEAMS REINFORCEMENT Rinforzo pilastri in c.a.IT. No. Art. n.17mq
91CLAY-R.C. SLABS REINFORCEMENT Rinforzo travi c.a. con FRPIT. No. Art. n.18m
92CLAY-R.C. SLABS REINFORCEMENT Rinforzo solai in latero-c.a. con spess. fino a 20 cmIT. No. Art. n.19mq
93STRUCTURES ANCHORING Rinforzo solai in latero-c.a. con spess. oltre a 20 cmIT. No. Art. n.20m
94STRUCTURES ANCHORING - STEEL BARS 12 mm
Ancoraggio strutture con barre fino a 12mm, in acciaio e resinaIT. No. Art. n.21Ea./No.
95STRUCTURES ANCHORING - STEEL BARS 20 mm
Ancoraggio strutture con barre fino a 20mm, in acciaio e resinaIT. No. Art. n.22Ea./No.
96TESTING OF THE STRUCTURE
Collaudo della strutturaIT. No. Art. n.23Ls/Ac
Total Structural Work - Totale Lavori strutturali
IIc Civil Work - IIc Lavori Civili
97HDPE PIPES
Tubi PEADIT. No. Art. n.1
98HDPE PIPES DIAM: 125mm
Tubi PEAD diametro 125mmIT. No. Art. n.1am
99HDPE PIPES DIAM: 125mm
Tubi PEAD diametro 125mmIT. No. Art. n.1bm
100PRE CAST CONCRETE PITS
Pozzetti PrefabbricatiIT. No. Art. n.2Ea./No.
101PRE CAST CONCRETE PITS 60x60cm
Pozzetti Prefabbricati 60x60cmIT. No. Art. n.2aEa./No.
102STORM WATER DRAINAGE FIELD
Sistema di dispersione superficiale acque meteoricheIT. No. Art. n.3LS/AC
103GENERAL SEWER SYSTEM impianto generale fognaturaIT. No. Art. n.4LS/AC
Total Civil Work - Totale Lavori civili
TOTAL PART II / Totale Parte II
PART III - MECHANICAL WORK / Parte III - Lavori Meccanici
PART IIIa - HVAC SYSTEMS / Parte IIIa -Impianti HVAC
104HEATING PREINSULATED COPPER PIPE
Tubazione in rame preisolata per riscaldamentoIT. No. Art. n.1
105DIAMETER 14x1 mm
Diametro 14x1 mmIT. No. Art. n.1am
106COPPER PIPE
Tubazione in rameIT. No. Art. n.2
107DIAMETER 22x1,5 mm
Diametro 22x1,5 mmIT. No. Art. n.2am
108DIAMETER 28x1,5 mm
Diametro 28x1,5 mmIT. No. Art. n.2bm
109HEATED ROOMS HOT PIPES INSULATION
Isolamento per tubazioni calde in locali riscaldatiIT. No. Art. n.3
110DIAMETER DN 15
Diametro DN 15IT. No. Art. n.3am
111NOT HEATED ROOMS HOT PIPES INSULATION
Isolamento per tubazioni calde in locali non riscaldatiIT. No. Art. n.4
112DIAMETER DN 20
Diametro DN 20IT. No. Art. n.4am
113COMMUNICATION ROOM AIR CONDITIONING
Condizionatore communication roomIT. No. Art. n.5EA/NO
114FURNISHING AND INSTALLATION OF WALL MOUNTED STEEL CONDENSING BOILER FOR METHANE GAS, CONTROL PANEL AND FITTINGS. TYPE VAILLANT VM806 AND CONTROL PANEL CALORMATIC 630 Fornitura e posa in opera di caldaia murale a condensazione in acciaio per gas metano, pannello di comando ed accessori. Tipo VAILLANT VM806 e pannello CALORMATIC 630IT. No. Art. n.6EA/NO
115INAIL COMPONENTS AND FITTINGS
Componenti INAIL ed accessoriIT. No. Art. n.7Ls/Ac
116FURNISHING AND INSTALLATION OF PPR CONCENTRIC CHIMNEY AND FITTINGS Fornitura e posa in opera di camino concentrico in polipropilene ed accessoriIT. No. Art. n.8
117DIAMETER 110/160 mm
Diametro 110/160 mmIT. No. Art. n.8am
118FURNISHING AND INSTALLATION OF HOT WATER STEEL PIPING
Fornitura e posa in opera di tubazioni in acciaio per acqua caldaIT. No. Art. n.9kg
119PIPING INSULATIONS
Coibentazione tubazioniIT. No. Art. n.10m
120PIPING ALUMINUM JACKET COVER
Rivestimento in alluminio delle tubazioniIT. No. Art. n.11mq
121FURNISHING AND INSTALLATION OF WET ROTOR SINGLE PUMP AND FITTINGS. TYPE GRUNDFOS ALPHA2 25/40 Fornitura e posa in opera di elettropompa singola a rotore bagnato ed accessori. Tipo GRUNDFOS ALPHA2 25/40IT. No. Art. n.12EA/NO
122FURNISHING AND INSTALLATION OF WET ROTOR SINGLE PUMP AND FITTINGS. TYPE GRUNDFOS MAGNA1 32/60 Fornitura e posa in opera di elettropompa singola a rotore bagnato ed accessori. Tipo GRUNDFOS MAGNA1 32/60IT. No. Art. n.13EA/NO
123FURNISHING AND INSTALLATION OF WET ROTOR SINGLE PUMP AND FITTINGS. TYPE GRUNDFOS UP 20/30N Fornitura e posa in opera di elettropompa singola a rotore bagnato ed accessori. Tipo GRUNDFOS UP 20/30NIT. No. Art. n.14EA/NO
124AUTOMATIC FILLING UNIT WITH PRESSURE GAUGE AND FITTINGS
Gruppo di riempimento con manometro ed accessoriIT. No. Art. n.15
125SIZE DN15 mm
Estremità filettate - Dimensione DN15 mmIT. No. Art. n.15aEA/NO
126EXPANSION VESSEL
Vaso d'espansioneIT. No. Art. n.16
127VOLUME 24 LITERS
Volume 24 litriIT. No. Art. n.16aEA/NO
128EXPANSION VESSEL FOR SANITARY WATER
Vaso d'espansione per acqua calda sanitariaIT. No. Art. n.17
129VOLUME 24 LITERS
Volume 24 litriIT. No. Art. n.17aEA/NO
130PRESSURE GAUGE
Manometro pressioneIT. No. Art. n.18EA/NO
131THERMOMETER
TermometroIT. No. Art. n.19EA/NO
132PN 16 BALL VALVES AND FITTINGS
Valvole a sfera ed accessori PN 16IT. No. Art. n.20
133SIZE DN15 mm
Dimensione DN15 mmIT. No. Art. n.20aEA/NO
134SIZE DN25 mm
Dimensione DN25 mmIT. No. Art. n.20bEA/NO
135SIZE DN40 mm
Dimensione DN40 mmIT. No. Art. n.20cEA/NO
136SIZE DN50 mm
Dimensione DN50 mmIT. No. Art. n.20dEA/NO
137PN 16 FLEXIBLE JOINTS AND FITTINGS
Giunti flessibili ed accessori PN 16IT. No. Art. n.21
138SIZE DN25 mm
Estremità filettate - Dimensione DN25 mmIT. No. Art. n.21aEA/NO
139SIZE DN40 mm
Estremità filettate - Dimensione DN40 mmIT. No. Art. n.21bEA/NO
140PN 16 NO RUTURN VALVE AND FITTINGS
Valvola di non ritorno ed accessori PN 16IT. No. Art. n.22
141SIZE DN25 mm
Estremità filettate - Dimensione DN25 mmIT. No. Art. n.22aEA/NO
142SIZE DN40 mm
Estremità filettate - Dimensione DN40 mmIT. No. Art. n.22bEA/NO
143WATER CARTRIDGE FILTER AND FITTINGS
Filtro a cartuccia ed accessoriIT. No. Art. n.23
144SIZE DN50 mm
Estremità filettate - Dimensione DN50mmIT. No. Art. n.23aEA/NO
145SINGLE COLUMN IONIC EXCHANGE WATER SOFTENER AND FITTINGS
Addolcitore a scambio ionico a singola colonna ed accessoriIT. No. Art. n.24
146REFINED FLOW 1,33 l/s, CYCLICAL CAPACITY 530°F
Portata trattata 1,33 l/s, capacità ciclica 530°FIT. No. Art. n.24aEA/NO
147HEAT EXCHANGER Scambiatore di caloreIT. No. Art. n.25EA/NO
148SANITARY HOT WATER TANK 320 LITRI Bollitore acqua calda sanitaria 320 litriIT. No. Art. n.26EA/NO
Total HVAC Systems - Totale Impianti HVAC
PART IIIb - PLUMBING SYSTEM / PARTE IIIa - Impianto Idrico-sanitario
149W.C. UNIT
Vaso sospeso senza cassettaIT. No. Art. n.1EA/NO
150HANDICAPPED W.C. UNIT
Vaso per disabiliIT. No. Art. n.2EA/NO
151HAND BASIN
LavaboIT. No. Art. n.3EA/NO
152HANDICAPPED HAND BASIN
Lavabo per disabiliIT. No. Art. n.4EA/NO
153PLUMBING CONNECTION
Allaccio idrico e scaricoIT. No. Art. n.5
154FOR W.C. UNIT
Per vaso sospesoIT. No. Art. n.5aLs/Ac
155FOR HANDICAPPED W.C. UNIT
Per vaso disabiliIT. No. Art. n.5bLs/Ac
156FOR HAND BASIN
Per lavaboIT. No. Art. n.5cLs/Ac
157FOR HANDICAPPED HAND BASIN
Per lavabo disabiliIT. No. Art. n.5dLs/Ac
158MULTILAYER PIPES AND FITTINGS
Tubazione multistratoIT. No. Art. n.6
159DIAMETER 26 mm
Diametro 26 mmIT. No. Art. n.6am
160DIAMETER 32 mm
Diametro 32 mmIT. No. Art. n.6bm
161DIAMETER 40 mm
Diametro 40 mmIT. No. Art. n.6cm
162DIAMETER 50 mm
Diametro 50 mmIT. No. Art. n.6dm
163DIAMETER 63 mm
Diametro 63 mmIT. No. Art. n.6em
164HEATED ROOMS HOT PIPES INSULATION
Isolamento per tubazioni calde in locali riscaldatiIT. No. Art. n.7
165DIAMETER DN 20
Diametro DN 20IT. No. Art. n.7am
166DIAMETER DN 25
Diametro DN 25IT. No. Art. n.7bm
167DIAMETER DN 32
Diametro DN 32IT. No. Art. n.7cm
168DIAMETER DN 40
Diametro DN 40IT. No. Art. n.7dm
169COLD PIPES INSULATION
Isolamento per tubazioni freddeIT. No. Art. n.8
170DIAMETER DN 20
Diametro DN 20IT. No. Art. n.8am
171DIAMETER DN 25
Diametro DN 25IT. No. Art. n.8bm
172DIAMETER DN 32
Diametro DN 32IT. No. Art. n.8cm
173DIAMETER DN 40
Diametro DN 40IT. No. Art. n.8dm
174DIAMETER DN 50
Diametro DN 50IT. No. Art. n.8em
175HDPE PIPES AND FITTINGS
Tubazioni in polietilene alta densitàIT. No. Art. n.9
176SIZE 32 mm
Dimensione 32 mmIT. No. Art. n.9am
177SIZE 50 mm
Dimensione 50 mmIT. No. Art. n.9bm
178SIZE 110 mm
Dimensione 110 mmIT. No. Art. n.9cm
179SIZE 125 mm
Dimensione 125 mmIT. No. Art. n.9dm
180PN 16 BALL VALVES AND FITTINGS
Valvole a sfera ed accessori PN 16IT. No. Art. n.10
181SIZE DN20 mm
Dimensione DN20 mmIT. No. Art. n.10aEA/NO
182SIZE DN25 mm
Dimensione DN25 mmIT. No. Art. n.10bEA/NO
183SIZE DN32 mm
Dimensione DN32 mmIT. No. Art. n.10cEA/NO
184SIZE DN40 mm
Dimensione DN40 mmIT. No. Art. n.10dEA/NO
185SIZE DN50 mm
Dimensione DN50 mmIT. No. Art. n.10eEA/NO
186HDPE PIPES AND FITTINGS FOR SANITARY WATER
Tubazioni in polietilene alta densità per idricoIT. No. Art. n.11
187SIZE 63 mm
Dimensione 63 mmIT. No. Art. n.11am
Total Plumbing System - Totale Impianto Idrico-Sanitario
TOTAL PART III / Totale Parte III
PART IV- ELECTRICAL WORK / Parte VI - Lavori Elettrici
188GALVANIZED STEEL METAL CABLE TRAY 400x80mm
Canale in acciaio zincato 400X80mmIT. No. Art. n.1am
189GALVANIZED STEEL METAL CABLE TRAY 300x80mm
Canale in acciaio zincato 300X80mmIT. No. Art. n.1bm
190GALVANIZED STEEL METAL CABLE TRAY 200x80mm
Canale in acciaio zincato 200X80mmIT. No. Art. n.1cm
191GALVANIZED STEEL METAL CABLE TRAY 150x80mm
Canale in acciaio zincato 150X80mmIT. No. Art. n.1dm
192GALVANIZED STEEL METAL CABLE TRAY 100x80mm
Canale in acciaio zincato 100X80mmIT. No. Art. n.1em
193GALVANIZED STEEL TUBE IP55 DN20 - 3/4"
Tubo in acciaio zincato IP55 DN20 - 3/4"IT. No. Art. n.2am
194GALVANIZED STEEL TUBE IP55 DN25 - 1"
Tubo in acciaio zincato IP55 DN25 - 1"IT. No. Art. n.2bm
195GALVANIZED STEEL TUBE IP55 DN32 - 1 1/4"
Tubo in acciaio zincato IP55 DN32 - 1 1/4"IT. No. Art. n.2cm
196GALVANIZED STEEL TUBE IP55 D40 - 1 1/2"
Tubo in acciaio zincato IP55 D40 - 1 1/2"IT. No. Art. n.2dm
197RIGID PVC TUBE RK TYPE D20
Tubo RK rigido in PVC D20IT. No. Art. n.3am
198RIGID PVC TUBE RK TYPE D25
Tubo RK rigido in PVC D25IT. No. Art. n.3bm
199RIGID PVC TUBE RK TYPE D32
Tubo RK rigido in PVC D32IT. No. Art. n.3cm
200RIGID PVC TUBE RK TYPE D40
Tubo RK rigido in PVC D40IT. No. Art. n.3dm
201RIGID PVC TUBE RK TYPE D50
Tubo RK rigido in PVC D50IT. No. Art. n.3em
202FLEXIBLE PVC TUBE FK TYPE D20
Tubo FK flessibile in PVC D20IT. No. Art. n.4am
203FLEXIBLE PVC TUBE FK TYPE D25
Tubo FK flessibile in PVC D25IT. No. Art. n.4bm
204FLEXIBLE PVC TUBE FK TYPE D32
Tubo FK flessibile in PVC D32IT. No. Art. n.4cm
205FLEXIBLE PVC TUBE FK TYPE D40
Tubo FK flessibile in PVC D40IT. No. Art. n.4dm
206DOUBLE LAYER CORRUGATED PVC CONDUIT D40
Tubo corrugato in PVC doppia parete D40IT. No. Art. n.5am
207DOUBLE LAYER CORRUGATED PVC CONDUIT D75
Tubo corrugato in PVC doppia parete D75IT. No. Art. n.5bm
208DOUBLE LAYER CORRUGATED PVC CONDUIT D160
Tubo corrugato in PVC doppia parete D160IT. No. Art. n.5cm
209CABLING FOR MAIN DISTRIBUTION AND GENERATOR
Cablaggi per distribuzione principale e generatoreIT. No. Art. n.6Ls/Ac
210CABLING FOR SECONDARY DISTRIBUTION
Cablaggi per distribuzione secondariaIT. No. Art. n.7Ls/Ac
211MAIN ELECTRIC PANEL MDP
Quadro elettrico generale MDPIT. No. Art. n.8Ls/Ac
212GENERATOR PANEL QE-GE
Quadro gruppo elettrogeno QE-GEIT. No. Art. n.9Ls/Ac
213DISTRIBUTION PANEL GROUND FLOOR MDP-GF
Quadro di distribuzione piano terra MDP-GFIT. No. Art. n.10Ls/Ac
214DISTRIBUTION PANEL FIRST FLOOR MDP-1F
Quadro di distribuzione piano primo MDP-1FIT. No. Art. n.11Ls/Ac
215DISTRIBUTION PANEL SECOND FLOOR MDP-2F
Quadro di distribuzione piano secondo MDP-2FIT. No. Art. n.12Ls/Ac
216BOILER ROOM DISTRIBUTION PANEL QE-CT
Quadro di distribuzione centrale termica QE-CTIT. No. Art. n.13Ls/Ac
217ELEVATOR PANEL QE-ELV
Quadro ascensore QE-ELVIT. No. Art. n.14Ls/Ac
218PANEL Q1GF GROUND FLOOR
Quadro piano terra Q1GFIT. No. Art. n.15EA/NO
219PANEL Q2GF GROUND FLOOR
Quadro piano terra Q2GFIT. No. Art. n.16EA/NO
220KITCHEN PANEL QKGF GROUND FLOOR
Quadro cucina piano terra QKGFIT. No. Art. n.17EA/NO
221PANEL Q1FF FIRST FLOOR
Quadro piano primo Q1FFIT. No. Art. n.18EA/NO
222PANEL Q2FF FIRST FLOOR
Quadro piano primo Q2FFIT. No. Art. n.19EA/NO
223PANEL Q1SF SECOND FLOOR
Quadro secondo piano Q1SFIT. No. Art. n.20EA/NO
224PANEL Q2SF SECOND FLOOR
Quadro secondo piano Q2SFIT. No. Art. n.21EA/NO
223DISTRIBUZIONE PANEL THIRD FLOOR MDP-3F
Quadro di distribuzione piano terzo MDP-3FIT. No. Art. n.22EA/NO
224FACILITY GROUNDING DISTRIBUTION
Rete di terra dell'edificioIT. No. Art. n.23Ls/Ac
225OUTLET TERMINAL BOX - SINGLE SUPPLY
Quadretto prese - alimentazione singolaIT. No. Art. n.24EA/NO
226OUTLET TERMINAL BOX - DOUBLE SUPPLY
Quadretto prese - alimentazione doppiaIT. No. Art. n.25EA/NO
22710/16A OUTLET UNIVERSAL TYPE
Presa 10/16A del tipo universalIT. No. Art. n.26EA/NO
22810/16A OUTLET UNIVERSAL TYPE IN ADDITION INTO A BOX
Presa 10/16A del tipo universal in aggiuntaIT. No. Art. n.27EA/NO
22916A OUTLET UNIVERSAL WATERPROOF TYPE
Presa 16A del tipo universale stagnaIT. No. Art. n.28EA/NO
230ELECTRICAL RAZOR OUTLET 20VA
Presa per rasoio elettrico 20VAIT. No. Art. n.29EA/NO
231SINGLE PHASE 16A CEE OUTLET WITH FUSES
Presa 16A monofase tipo CEE con fusibiliIT. No. Art. n.30EA/NO
232THREE PHASE 16A CEE OUTLET WITH FUSES
Presa 16A trifase tipo CEE con fusibiliIT. No. Art. n.31EA/NO
233POWER SUPPLY POINT WITH BIPOLAR SWITCH
Punto di alimentazione con interruttore bipolareIT. No. Art. n.32aEA/NO
234FURNISHING AND INSTALLATION OF WALL FLUSHED POWER POINT FOR GENERAL USE (FOR MECHANICAL SYSTEM WITH UNDERLOAD CUTOFF SWITCH, IN WATERPR. BOX IP44)
Fornitura e posa in opera di punto di alimentazione generale ( a servizio dell'impianto meccanico con sezionatore sotto carico all'interno di cassetta Ip44)IT. No. Art. n.32bEA/NO
235INTERNAL LIGHTING FIXTURE 4x14W T16 DARK LIGHT
Corpo illuminante interno 4x14W T16 dark lightIT. No. Art. n.33EA/NO