(Attachment 64) SABER Seed SOO Honor Guard Building 10250 Attachment 11- Testing on exterior paint walls dated 6 November 2014.pdf
PDF 1 MB Posted
- Attached to
- SABER IDIQ
- Solicitation number
- FA486125R0003
About this file
This document is an Asbestos and Lead Based Paint Inspection Report for Building 10252 at Nellis Air Force Base, conducted by Macrotec Consulting, LLC on November 10, 2014. The inspection involved using an XRF analyzer to test various metal surfaces including walls, doors, doorframes, and vents for the presence of asbestos and lead-based paint. The comprehensive report found no suspect asbestos-containing materials and no lead detected during the inspection of the exterior metal surfaces. The work order, numbered 24743, was initiated by Ms. Ida Campbell from the 99 CES (Civil Engineering Squadron) to install a number sign on the facility, with the justification that numbered signs are required for easy identification.
The report includes detailed documentation such as a sample location diagram showing the exterior of Building 10252, an XRF Data Table listing specific measurement times, components tested, and results, and appendices for asbestos and lead assessments. The inspection methodology emphasized stopping work immediately and conducting further testing if any suspect materials are discovered during renovation activities beyond the scope of this initial assessment. The report was prepared by Dustin R. McAllister, a Nevada-OSHA Certified Asbestos Abatement Consultant and US EPA Lead Risk Assessor, providing professional certification for the inspection findings.
View the file
Other files
Show 40 more
Latest 50 of 126 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report
Work Order Scope of Work:
Check paint on exterior walls.
Building Number: 10252
Inspection Date: 11/10/2014
Nellis Work Order: 24743
Macrotec Job Number: 14718
The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building.
Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.
Introduction:
Report Limitations:
Dustin R. McAllister Nevada - OSHA Certified Asbestos Abatement Consultant Certificate #IM0961 US EPA Lead Risk Assessor Certificate #NV-R-16781-2
Office@MacrotecConsulting.com Phone: (702) 949-6225 Fax: (702) 629-5677
Macrotec Consulting, LLC.
Appendix A - Asbestos Assessment
Macrotec Job #14718 - Bldg. 10252
No suspect asbestos containing materials were identified during this investigation, based on the specific scope of work for the project. If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.
Asbestos Survey
WO #24743 - Bldg. 10252
Macrotec Job #14718
Macrotec Consulting, LLC.
Appendix B - Lead Assessment
Macrotec Job #14718 - Bldg. 10252
Macrotec conducted analysis of the painted surfaces and/or bulk materials that may be impacted during the defined scope of work, using an XRF analyzer. No lead was detected during the inspection of the suspect materials. Appendix D lists the painted surfaces that were analyzed during this inspection along with its location and analysis result. Note: If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.
Lead Paint Survey
WO #24743 - Bldg. 10252
Macrotec Job #14718
Asbestos & Lead Based Paint Survey
Nellis AFB, Bldg. 10252
Macrotec Project # 14718
Appendix C
* Diagram Not Drawn To Scale
Sample Location Diagram
N
The Walls in the Picture Above Was Tested for Lead Based Paint with a XRF Analyzer. See Results Page for Materials & Locations.
XRF Data Table
Time Duration Component Substrate Side Color Condition Building Room Results Depth PbC PbC Error PbL PbL Error PbK PbK Error
11/6/14 13:18 1.09 Wall Metal A Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.22
11/6/14 13:18 1.09 Vent Metal A Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.73
11/6/14 13:18 1.08 Roll Door Metal A Brown Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.52
11/6/14 13:19 1.08 Roll Doorframe Metal A Brown Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.64
11/6/14 13:19 1.08 Wall Metal A Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.56
11/6/14 13:19 1.09 Wall Metal B Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.3
11/6/14 13:20 0.62 Door Metal B Brown Intact 10252 Exterior Null 1 < LOD 0.03 < LOD 0.03 < LOD 7.18
11/6/14 13:20 1.08 Door Metal B Brown Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.78
11/6/14 13:20 1.08 Doorframe Metal B Brown Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.35
11/6/14 13:20 1.09 Vent Metal B Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.89
11/6/14 13:21 0.16 Wall Metal C Beige Intact 10252 Exterior Null 1 < LOD 0.03 < LOD 0.03 < LOD 15.6
11/6/14 13:21 0.78 Wall Metal C Beige Intact 10252 Exterior Null 1 < LOD 0.03 < LOD 0.03 < LOD 6.3
11/6/14 13:21 1.09 Wall Metal C Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.74
11/6/14 13:21 1.09 Pole Metal C Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.35
11/6/14 13:21 1.08 Wall Metal C Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.36
11/6/14 13:22 1.08 Wall Metal D Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.14
11/6/14 13:22 1.08 Door Metal D Brown Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.01
11/6/14 13:22 0.93 Doorframe Metal D Brown Intact 10252 Exterior Null 10 < LOD 0.25 < LOD 0.25 < LOD 4.86
11/6/14 13:22 1.09 Doorframe Metal D Brown Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.71
11/6/14 13:22 0.62 Wall Metal D Beige Intact 10252 Exterior Null 1 < LOD 0.03 < LOD 0.03 < LOD 5.7
11/6/14 13:23 1.08 Wall Metal D Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.01
11/6/14 13:23 1.08 Vent Metal D Beige Intact 10252 Exterior Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.93
11/6/14 13:24 0.93 Cal Orange Positive 1.32 1.9 0.9 1.9 0.9 < LOD 5.25
11/6/14 13:24 1.09 Cal Orange Positive 1.09 1.5 0.5 1.5 0.5 < LOD 3.75
11/6/14 13:24 1.39 Cal Orange Positive 1.11 1.5 0.4 1.5 0.4 < LOD 3.3
Nellis Air Force Base Bldg. 10252 Macrotec Job #14718 1
| 1 14718 - fp.pdf |
| 2 14718 - asb asses.pdf |
| 3 14718 - pb asses.pdf |
| 4 14718 - Diagram.pdf |
| 6 14718 - xrf.pdf |
| 7 14718 - wo.pdf |
File details come from the government source that posted it. Updated .