(Attachment 65) SABER Seed SOO Honor Guard Building 10250 Attachment 12 - Mech. Room Report.pdf
PDF 673 KB Posted
- Attached to
- SABER IDIQ
- Solicitation number
- FA486125R0003
About this file
This document is an Asbestos Hazard Inspection Report for Building 10250 at Nellis Air Force Base, prepared by Macrotec Consulting, LLC on August 4, 2016. The inspection, conducted by certified asbestos inspector Dustin R McAllister, focused on identifying the presence of asbestos-containing Thermal System Insulation (TSI) and Surfacing Material in the building's mechanical room and mechanical yard. Laboratory testing of two samples (black pipe wrap and mud on HVAC ducts) by Triangle Environmental Service Center revealed No Asbestos Detected (NAD), with one sample containing 20% fiberglass and the other 100% non-fibrous materials.
The report emphasizes that while no asbestos-containing materials were found in the mechanical room and yard, additional suspect asbestos-containing materials may exist in other areas of the building. The inspection was not a comprehensive NESHAP (National Emission Standards for Hazardous Air Pollutants) assessment for renovation purposes, but rather a targeted examination of specific mechanical areas. Photographic documentation was included to show the inspected areas, which consisted of one mechanical room with a black pipe wrap and one mechanical yard with bare pipes and HVAC ducts.
View the file
Other files
Show 40 more
Latest 50 of 126 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Nellis Air Force Base Asbestos Hazard Inspection Report
Building Number: 10250
The information contained in this report pertains only to the specific rooms identified.
Macrotec made an effort to identify and inspect each of the building's mechanical rooms, however there may be instances where they may have not been identified or been in high security rooms, etc. Building diagrams were not always provided and when they were, were sometimes out of date. Macrotec also noted if there are suspicions of, or visual evidence of suspect TSI or Surfacing Materials in areas other than the mechanical room, however, Macrotec cannot warrant that there are not additional suspect materials outside of the mechanical rooms identified. Only proper personnel should interpret this report to determine whether the information herein can be utilized.
On 8/4/2016, Dustin R McAllister, a certified asbestos inspector for Macrotec Consulting, LLC., performed an inspection to identify the presence or absence of asbestos hazards in the mechanical room(s) of the building. Specifically, Macrotec inspected for the presence of asbestos containing Thermal System Insulation (TSI) and Surfacing Material and made a determination of the condition of these materials, if present. Note that this inspection is not a NESHAP inspection that would identify asbestos containing building materials for the purpose of renovating the rooms or components in the rooms.
No asbetos containing TSI or Surfacing Material were found in the mechanical room(s) of building 10250. Please note that these materials and other suspect asbestos containing materials may be present in other areas of the building.
Report Limitations:
Bldg. 10250 has one mechanical room and one mechanical yard. The mechanical room one black pipe wrap that does not contain asbestos. The mechanical yards has bare pipes and mud on HVAC ducts that was tested and found to not contain asbestos.
Building 10250 Inspection Details:
Introduction:
Office@MacrotecConsulting.com Phone: (702) 949-6225 Fax: (702) 629-5677
Mech. Room Investigation Macrotec Project # 16603 Nellis Air Force Base, Bldg. 10250 Appendix A
Building 10250 has one mechanical room and one exterior mechanical yard. Above is the mechanical room that has one black pipe wrap that was tested and found to not contain asbestos.
The mechanical yard has mud on HVAC duct that was tested and found to not contain asbestos.
Above is the another picture of the mechanical room that has bare ducts an bare pipes
The mechanical yard has bare pipes.
Appendix B - Assessment
Macrotec Job #16603 - Building 10250
Laboratory reports are attached with this report (if samples were collected). Please note that the primary purpose of this inspection was to determine the presence of TSI or Surfacing Material in the mechanical rooms/areas. Additional suspect asbestos containing TSI or Surfacing Material may be present in other rooms/areas of the building.
Mechanical Room
One black pipe wrap
No ACM Present : Samples Collected :
Mechanical Yard
Bare pipes and mud on HVAC ducts
No ACM Present : Samples Collected :
Asbestos Inspection
Building 10250
Macrotec Job #16603 Appendix B
Macrotec Consulting
TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.
13509 East Boundary Road, Suite B, Midlothian, VA 23112
804-739-1751 • fax: 804-739-1753
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
16603-10250
WO #28328 - Bldg. 10250
160809X
08/09/2016
08/10/2016
08/10/2016
B.TrimmerJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB:
100%AB1 / Black foam NAD1
20% Fiberglass 80%AB2 / Foil, white fibers, gray adhesive NAD2
Total Samples/Layers Analyzed: 2
August 10, 2016 Page 1 of 1
Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA 600/M4-82-020, Dec. 1982 and "Method for the Determination of Asbestos in Bulk Building Materials", EPA 600/R-93/116, July 1993. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission
Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report shall not be reproduced, except in full written approval of Triangle Environmental Service Center, Inc. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
Macrotec Consul , LLC
Client Name Nellis Bulk Sampling Chain of Custody Form
Project Name Bldg' 7O25O
Project Location lrJO #25328 - Bldg. IO2SO Technician _Dus'tin R /llc1llister Laboratorv .rE:;c
Stop at 1st pol;itive?: y / N Composite Wall Substrate?: y / N
Project Number
Collection Date
WO Number
7(;603-70250 a/4/2076 ,28325
Turn Around Time
Method of Analysis
Matrix Eulk
3 DaLl
,PLm
Sample # H # lCount
Sample Description Material Type : Color / Deserinr sampreto,ffi (General : Room : Soecifie\ nE/ nB2
P,'pe l,tttrqp - Black lnterior - //lech Room - N :;ide
Exterior - /llech yard - ld side
Relinquished By:
Relinquished By:
( neceiveo
Received By:
| As Lab 10250.pdf |
| 160809x |
| 160809x |
File details come from the government source that posted it. Updated .