(Attachment 63) SABER Seed SOO Honor Guard Building 10250 Attachment 10 - Asbestos and Lead testing dated 24 February 2014.pdf

PDF 2 MB Posted

Attached to
SABER IDIQ
Solicitation number
FA486125R0003
Issued by

About this file

This document is a Base Civil Engineer Work Request for Base Information Transport Infrastructure (BITI) construction at Nellis Air Force Base. The work order (No. 23065) covers installation activities in Building 10250, specifically detailing planned construction for a network infrastructure upgrade. The scope includes electrical circuit installation (typical 20/30 Amp), wall and floor mounted cabinet installation, core drilling, and associated minor construction tasks.

Accompanying the work request are supporting documents including an Asbestos and Lead Based Paint Inspection Report by Macrotec Consulting, LLC. The inspection, conducted on 2/24/2014, tested multiple building materials (drywall, wall texture, VCT flooring, floor mastic) in the communications room. Laboratory analysis confirmed no asbestos or lead was detected in the sampled materials. The work is part of a downward-directed Nellis AFB base-wide data network upgrade, with the BITI contractor (General Dynamics) expected to complete the construction activities during the installation phase.

View the file

Other files

File Type Posted
Solicitation Amendment FA486125R00030017 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030017.pdf PDF
Atch 80_ RFI Response Log_General Solicitation 9 March 2026.xlsx XLSX spreadsheet
Solicitation Amendment FA486125R00030016 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030016.pdf PDF
Solicitation Amendment - FA486125R00030015.pdf PDF
Solicitation Amendment FA486125R00030015 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030014.pdf PDF
3 - Self Scoring Matrix 17 Feb 26.xlsx XLSX spreadsheet
Solicitation Amendment FA486125R00030014 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030013.pdf PDF
Solicitation Amendment FA486125R00030013 SF 30.pdf PDF
Attach 79 RFI Log SABER Seed 29 Jan 2026_.xlsx XLSX spreadsheet
Att 78 RFI Log Additional Responses General Solicitation 27 Jan 2026_.xlsx XLSX spreadsheet
Att 3 -Self Scoring Matrix 3_Feb_2026.xlsx XLSX spreadsheet
44- SABER SOO RKMF240010 Renovate Honor Guard 99 FSS B10250_28January2026 (003).pdf PDF
Solicitation Amendment FA486125R00030012 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030012.pdf PDF
Solicitation Amendment FA486125R00030011 SF 30 .pdf PDF
1 - SABER SOW 7 Jan 2026.pdf PDF
Solicitation Amendment - FA486125R00030011.pdf PDF
2 - Price Schedule _13 Jan 2026.xlsx XLSX spreadsheet
3 - Self Scoring Matrix 7_Jan 26.xlsx XLSX spreadsheet
77 - RFI Response Log SABER Seed Related _ 13_Jan 2026.xlsx XLSX spreadsheet
Solicitation Amendment - FA486125R00030010.pdf PDF
44 -Statement of Objectives (SOO) for RKMF 240010 20 Nov 25.pdf PDF
Attach 75 SABER Seed Attachment 19 - B10250 comm room.pdf PDF
Attach 74 SABER Seed Attachment 18 - Knox Box Location.pdf PDF
73 - Task Order Pricing Letter _ Gordian System Licens Fees 5 percent and 1.95 percent.pdf PDF
1- SABER SOW 7 Jan 2025 .pdf PDF
76 - RFI Response Log General Solicitation 13_Jan 26.xlsx XLSX spreadsheet
Solicitation Amendment FA486125R00030010 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030009.pdf PDF
Solicitation Amendment FA486125R00030009_SF 30.pdf PDF
Solicitation Amendment FA486125R00030007 SF 30.pdf PDF
Solicitation Amendment FA486125R00030006 SF 30.pdf PDF
(Attachment 65) SABER Seed SOO Honor Guard Building 10250 Attachment 12 - Mech. Room Report.pdf PDF
(Attachment 66) SABER Seed SOO Honor Guard Building 10250 Attachment 13 - Asbestos and Lead testing building history.xlsx XLSX spreadsheet
Solicitation Amendment - FA486125R00030006.pdf PDF
Attachment 72 SABER IDIQ Preproposal Sign In Sheet 29 October 2025 FA486125R0003.pdf PDF
(Attachment 68) SABER Seed SOO Honor Guard Building 10250 Attachment 15 - B10250 room numbers.pdf PDF
(Attachment 55) SABER Seed SOO Honor Guard Building 10250 Attachment 1 - HAZMAT Results 10250 Restrooms Part 1.pdf PDF
(Attachment 58) SABER Seed SOO Honor Guard Building 10250 Attachment 5 - Attachment 5 AFGIMS Utilities Snapshot.pdf PDF
(Attachment 69) SABER Seed SOO Honor Guard Building 10250 Attachment 16 - 10250 BFP Device replacement.png PNG image
(Attachment 57) SABER Seed SOO Honor Guard Building 10250 Attachment 3 - As-Builts 65 LOCATION and GRADING.pdf PDF
(Attachment 70) SABER Seed SOO Honor Guard Building 10250 Attachment 17 - Double Check Valve Assembly.pdf PDF
(Attachment 60) SABER Seed SOO Honor Guard Building 10250 Attachment 7 - Sewer Line with Measurements and Pictures.pdf PDF
Attachment 71 SABER IDIQ Preproposal Conference Slides 29 October 2025 FA486125R0003.pptx PPTX presentation
(Attachment 61) SABER Seed SOO Honor Guard Building 10250 Attachment 8 - Asbestos and Lead testing of entire building dated 7 July 2007.pdf PDF
(Attachment 59) SABER Seed SOO Honor Guard Building 10250 Attachment 6 - Floorplan Conceptual.pdf PDF
Show 40 more

Latest 50 of 126 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report

Work Order Scope of Work:

Check path of lines for BITI construction.

Building Number: 10250

Inspection Date: 2/24/2014

Nellis Work Order: 23065

Macrotec Job Number: 14548

The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building.

Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.

Introduction:

Report Limitations:

Office@MacrotecConsulting.com Phone: (702) 949-6225 Fax: (702) 629-5677

Macrotec Consulting, LLC.

Appendix A - Asbestos Assessment

Macrotec Job #14548 - Bldg. 10250

The following table lists each of the materials suspected to contain asbestos at the subject site. For each material the sample number, location and laboratory result are listed. If the material was found to contain asbestos, the friablity and NESHAP classification is identified.

1 Wall & Ceiling Substrate (Drywall & Mud) - This material is located on the walls of the comm. room

No Asbestos Detected

None DetectedInterior - Comm. Room - SE cornerAB1

None DetectedInterior - Comm. Room - SW cornerAB2

2 Spary-on Wall & Ceiling Texture - This material is located atop the walls of the comm. room

No Asbestos Detected

None DetectedInterior - Comm. Room - N wallAB3

None DetectedInterior - Comm. Room - E wallAB4

None DetectedInterior - Comm. Room - W wallAB5

3 12X12 VCT - White This material is located on the floor of the comm. room

No Asbestos Detected

None DetectedInterior - Comm. Room - SE cornerAB6

4 VCT Floor Mastic - Yellow This material is located below the VCT flooring of the comm. room

No Asbestos Detected

None DetectedInterior - Comm. Room - SE cornerAB7

Asbestos Survey

WO #23065 - Bldg. 10250

Macrotec Job #14548

Appendix A

Macrotec Consulting, LLC.

Appendix B - Lead Assessment

Macrotec Job #14548 - Bldg. 10250

Macrotec conducted analysis of the painted surfaces and/or bulk materials that may be impacted during the defined scope of work, using an XRF analyzer. No lead was detected during the inspection of the suspect materials. Appendix D lists the painted surfaces that were analyzed during this inspection along with its location and analysis result. Note: If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.

Lead Paint Survey

WO #23065 - Bldg. 10250

Macrotec Job #14548

Asbestos and Lead Survey

NAFB, Bldg. 10250

Macrotec Project # 14548

Appendix C

* Diagram Not Drawn To Scale

Sample Location Diagram

AB1

The Red Outlined Area in the Picture Above Was Tested for Lead Based Paint with a XRF Analyzer. See Results Page for Materials

& Locations.

AB2

AB3

AB4

AB5

AB6

AB7

Macrotec Consulting

TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.

13509 East Boundary Road, Suite B, Midlothian, VA 23112

1*.(0-2(+0/+ ^ LI[3 1*.(0-2(+0/-

BULK ASBESTOS SAMPLE ANALYSIS SUMMARY

9724 Mild Weather Ct.

Las Vegas, NV 89148

14548

WO #23065 - Bldg. 10250

140226J

2/26/2014 2/27/2014 2/27/2014

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

CLIENT JOB:

20% Cellulose 80%AB1-Drywall / White powder, brown fibers NAD1A

100%AB1-Mud / White powder NAD1B

20% Cellulose 80%AB2-Drywall / White powder, brown fibers NAD2A

100%AB2-Mud / White powder NAD2B

100%AB3 / White powder NAD3

100%AB4 / White powder NAD4

100%AB5 / White powder NAD5

100%AB6 / White vinyl NAD6

100%AB7 / Yellow adhesive NAD7

Thursday, February 27, 2014 Page 1 of 2

JQ\_[Ub QaU Q]Q[hiUT Y] QSS^aTQ]SU fYcX jB]cUaY\ EUcX^T V^a cXU =UcUa\Y]QcY^] ^V 9bRUbc^b Y] ;d[Z B]bd[QcY^] JQ\_[Ubk( >H9 2,,+E0)4.),.,( =US* -54.

and "Method for the Determination of Asbestos in Bulk Building Materials", EPA 600/R-93/116, July 1993. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report shall not be reproduced, except in full written approval of Triangle Environmental Service Center, Inc. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound][

Reviewed By Authorized Signatory:

Feng Jiang, MS Senior Geologist, Laboratory Director Yuedong Fang, Senior Geologist

Macrotec Consulting

TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.

13509 East Boundary Road, Suite B, Midlothian, VA 23112

1*.(0-2(+0/+ ^ LI[3 1*.(0-2(+0/-

BULK ASBESTOS SAMPLE ANALYSIS SUMMARY

9724 Mild Weather Ct.

Las Vegas, NV 89148

14548

WO #23065 - Bldg. 10250

140226J

2/26/2014 2/27/2014 2/27/2014

F. JiangJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

CLIENT JOB:

Total Samples/Layers Analyzed: 9

Thursday, February 27, 2014 Page 2 of 2

JQ\_[Ub QaU Q]Q[hiUT Y] QSS^aTQ]SU fYcX jB]cUaY\ EUcX^T V^a cXU =UcUa\Y]QcY^] ^V 9bRUbc^b Y] ;d[Z B]bd[QcY^] JQ\_[Ubk( >H9 2,,+E0)4.),.,( =US* -54.

and "Method for the Determination of Asbestos in Bulk Building Materials", EPA 600/R-93/116, July 1993. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report shall not be reproduced, except in full written approval of Triangle Environmental Service Center, Inc. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the item(s) tested.

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound][

Reviewed By Authorized Signatory:

Feng Jiang, MS Senior Geologist, Laboratory Director Yuedong Fang, Senior Geologist

Time Duration Component Substrate Side Color Building Room Results Depth PbC PbC Error PbL PbL Error PbK PbK Error

2/24/14 9:38 3.15 Wall Drywall A White 10205 Comm Rm 111 NEG 2.2 < LOD 1.23 < LOD 0.03 < LOD 1.23

2/24/14 9:38 2.24 Wall Drywall B White 10205 Comm Rm 111 NEG 1.76 < LOD 0.03 < LOD 0.03 < LOD 2.18

2/24/14 9:38 1.8 Wall Drywall C White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 2.52

2/24/14 9:48 2.01 Wall Drywall D White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 2.29

2/24/14 9:48 2.7 Ceiling Drywall White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 1.88

2/24/14 9:48 3.15 Floor VCT White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 1.89

2/24/14 9:49 1.12 Wall Wood C White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 2.55

2/24/14 9:49 3.14 Wall Drywall C White 10205 Bay NEG 1 < LOD 0.03 < LOD 0.03 < LOD 1.31

2/24/14 10:06 3.8 Wall Drywall C White 10205 Bay NEG 1 < LOD 0.03 < LOD 0.03 < LOD 1.06

1 14548 - fp.pdf
2 14548 - asb asses.pdf
3 14548 - pb asses.pdf
4 14548 - Diag.pdf
5 14548 - asb lab.pdf
6 14548 - XRF.pdf
7 14548 - wo.pdf

File details come from the government source that posted it. Updated .