This document is a Base Civil Engineer Work Request for Base Information Transport Infrastructure (BITI) construction at Nellis Air Force Base. The work order (No. 23065) covers installation activities in Building 10250, specifically detailing planned construction for a network infrastructure upgrade. The scope includes electrical circuit installation (typical 20/30 Amp), wall and floor mounted cabinet installation, core drilling, and associated minor construction tasks.
Accompanying the work request are supporting documents including an Asbestos and Lead Based Paint Inspection Report by Macrotec Consulting, LLC. The inspection, conducted on 2/24/2014, tested multiple building materials (drywall, wall texture, VCT flooring, floor mastic) in the communications room. Laboratory analysis confirmed no asbestos or lead was detected in the sampled materials. The work is part of a downward-directed Nellis AFB base-wide data network upgrade, with the BITI contractor (General Dynamics) expected to complete the construction activities during the installation phase.
View the file
Other files
Show 40 more
Latest 50 of 126 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report
Work Order Scope of Work:
Check path of lines for BITI construction.
Building Number: 10250
Inspection Date: 2/24/2014
Nellis Work Order: 23065
Macrotec Job Number: 14548
The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building.
Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.
Introduction:
Report Limitations:
Office@MacrotecConsulting.com Phone: (702) 949-6225 Fax: (702) 629-5677
Macrotec Consulting, LLC.
Appendix A - Asbestos Assessment
Macrotec Job #14548 - Bldg. 10250
The following table lists each of the materials suspected to contain asbestos at the subject site. For each material the sample number, location and laboratory result are listed. If the material was found to contain asbestos, the friablity and NESHAP classification is identified.
1 Wall & Ceiling Substrate (Drywall & Mud) - This material is located on the walls of the comm. room
No Asbestos Detected
None DetectedInterior - Comm. Room - SE cornerAB1
None DetectedInterior - Comm. Room - SW cornerAB2
2 Spary-on Wall & Ceiling Texture - This material is located atop the walls of the comm. room
No Asbestos Detected
None DetectedInterior - Comm. Room - N wallAB3
None DetectedInterior - Comm. Room - E wallAB4
None DetectedInterior - Comm. Room - W wallAB5
3 12X12 VCT - White This material is located on the floor of the comm. room
No Asbestos Detected
None DetectedInterior - Comm. Room - SE cornerAB6
4 VCT Floor Mastic - Yellow This material is located below the VCT flooring of the comm. room
No Asbestos Detected
None DetectedInterior - Comm. Room - SE cornerAB7
Asbestos Survey
WO #23065 - Bldg. 10250
Macrotec Job #14548
Appendix A
Macrotec Consulting, LLC.
Appendix B - Lead Assessment
Macrotec Job #14548 - Bldg. 10250
Macrotec conducted analysis of the painted surfaces and/or bulk materials that may be impacted during the defined scope of work, using an XRF analyzer. No lead was detected during the inspection of the suspect materials. Appendix D lists the painted surfaces that were analyzed during this inspection along with its location and analysis result. Note: If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.
Lead Paint Survey
WO #23065 - Bldg. 10250
Macrotec Job #14548
Asbestos and Lead Survey
NAFB, Bldg. 10250
Macrotec Project # 14548
Appendix C
* Diagram Not Drawn To Scale
Sample Location Diagram
AB1
The Red Outlined Area in the Picture Above Was Tested for Lead Based Paint with a XRF Analyzer. See Results Page for Materials
& Locations.
AB2
AB3
AB4
AB5
AB6
AB7
Macrotec Consulting
TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.
13509 East Boundary Road, Suite B, Midlothian, VA 23112
1*.(0-2(+0/+ ^ LI[3 1*.(0-2(+0/-
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
14548
WO #23065 - Bldg. 10250
140226J
2/26/2014 2/27/2014 2/27/2014
F. JiangJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB:
20% Cellulose 80%AB1-Drywall / White powder, brown fibers NAD1A
100%AB1-Mud / White powder NAD1B
20% Cellulose 80%AB2-Drywall / White powder, brown fibers NAD2A
100%AB2-Mud / White powder NAD2B
100%AB3 / White powder NAD3
100%AB4 / White powder NAD4
100%AB5 / White powder NAD5
100%AB6 / White vinyl NAD6
100%AB7 / Yellow adhesive NAD7
Thursday, February 27, 2014 Page 1 of 2
JQ\_[Ub QaU Q]Q[hiUT Y] QSS^aTQ]SU fYcX jB]cUaY\ EUcX^T V^a cXU =UcUa\Y]QcY^] ^V 9bRUbc^b Y] ;d[Z B]bd[QcY^] JQ\_[Ubk( >H9 2,,+E0)4.),.,( =US* -54.
and "Method for the Determination of Asbestos in Bulk Building Materials", EPA 600/R-93/116, July 1993. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report shall not be reproduced, except in full written approval of Triangle Environmental Service Center, Inc. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound][
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director Yuedong Fang, Senior Geologist
Macrotec Consulting
TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.
13509 East Boundary Road, Suite B, Midlothian, VA 23112
1*.(0-2(+0/+ ^ LI[3 1*.(0-2(+0/-
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
14548
WO #23065 - Bldg. 10250
140226J
2/26/2014 2/27/2014 2/27/2014
F. JiangJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB:
Total Samples/Layers Analyzed: 9
Thursday, February 27, 2014 Page 2 of 2
JQ\_[Ub QaU Q]Q[hiUT Y] QSS^aTQ]SU fYcX jB]cUaY\ EUcX^T V^a cXU =UcUa\Y]QcY^] ^V 9bRUbc^b Y] ;d[Z B]bd[QcY^] JQ\_[Ubk( >H9 2,,+E0)4.),.,( =US* -54.
and "Method for the Determination of Asbestos in Bulk Building Materials", EPA 600/R-93/116, July 1993. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report shall not be reproduced, except in full written approval of Triangle Environmental Service Center, Inc. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the item(s) tested.
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound][
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director Yuedong Fang, Senior Geologist
Time Duration Component Substrate Side Color Building Room Results Depth PbC PbC Error PbL PbL Error PbK PbK Error
2/24/14 9:38 3.15 Wall Drywall A White 10205 Comm Rm 111 NEG 2.2 < LOD 1.23 < LOD 0.03 < LOD 1.23
2/24/14 9:38 2.24 Wall Drywall B White 10205 Comm Rm 111 NEG 1.76 < LOD 0.03 < LOD 0.03 < LOD 2.18
2/24/14 9:38 1.8 Wall Drywall C White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 2.52
2/24/14 9:48 2.01 Wall Drywall D White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 2.29
2/24/14 9:48 2.7 Ceiling Drywall White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 1.88
2/24/14 9:48 3.15 Floor VCT White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 1.89
2/24/14 9:49 1.12 Wall Wood C White 10205 Comm Rm 111 NEG 1 < LOD 0.03 < LOD 0.03 < LOD 2.55
2/24/14 9:49 3.14 Wall Drywall C White 10205 Bay NEG 1 < LOD 0.03 < LOD 0.03 < LOD 1.31
2/24/14 10:06 3.8 Wall Drywall C White 10205 Bay NEG 1 < LOD 0.03 < LOD 0.03 < LOD 1.06
| 1 14548 - fp.pdf |
| 2 14548 - asb asses.pdf |
| 3 14548 - pb asses.pdf |
| 4 14548 - Diag.pdf |
| 5 14548 - asb lab.pdf |
| 6 14548 - XRF.pdf |
| 7 14548 - wo.pdf |
File details come from the government source that posted it. Updated .