This document is an Asbestos and Lead Survey Report for Building 10250 at Nellis Air Force Base, conducted by DGM Environmental on 7/25/2007 (Job #107079). The comprehensive survey involved testing multiple interior and exterior locations for potential asbestos and lead-based paint contamination. Asbestos sampling included 22 different material samples from various areas such as sheet rock, floor tiles, mastic, textures, and roofing materials, with only two samples showing asbestos content: the mastic on flashing (10% Chrysotile) and built-up roofing beneath stone on the E Roof (8% Chrysotile). Lead testing examined 20 different materials, with several samples exceeding reportable limits, including a beige metal column (13,940 PPM), a brown metal door frame (2,120 PPM), and a beige cinder block wall (1,470 PPM). The report includes detailed sample location diagrams for both asbestos and lead testing, mapping the specific locations of each sample within the building.
View the file
Other files
Show 40 more
Latest 50 of 126 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
99th CES CEVNellis Work Order:
Test the building.
WO Scope of Work:
10250Building Number:
7/25/2007Inspection Date:
107079
DGM’s Job Number:
Nellis Air Force Base Asbestos and Lead Based Paint
Project Database
This project was conducted by DGM Environmental.
The information contained in this report pertains only to the specific area defined in the above work order scope of work. Only proper personel should interperet this report to determine whether the information herein can be utilized for future renovation activities within this building.
Asbestos Sample Results
Description Sample ID Content#
The following table provides an inventory of the suspect asbestos containing materials identified during DGM's inspection of the subject site. The table provides each of the materials unique sample identification number and corresponding laboratory result.
1 Sheet Rock Mud & Tape - Textured -
None Detected107079 AB1-Interior - Entrance Hall - Adj Exterior Door
None Detected107079 AB2-Interior - Day Care - NE Corner
None Detected107079 AB3-Interior - Main Room - Center
None Detected107079 AB4-Interior - Restroom 4 - Adj Door
None Detected107079 AB5-Interior - Restroom 2 - Adj Door
2 Texture - Atop Sheet Rock -
None Detected107079 AB6-Interior - Main Room - NE Corner
None Detected107079 AB7-Interior - Office 1 - N Wall
None Detected107079 AB8-Interior - Flotation Room - Center
None Detected107079 AB9-Interior - Back Hallway - Adj Door to Main Room
None Detected107079 AB10-Interior - Main Room - Center
3 Mastic - Beneath Carpet - Yellow
None Detected107079 AB11-Interior - Day Care - NE Corner
4 Floor Tile - 12X12 - White
None Detected107079 AB12-Interior - Main Room - Adj Desk
5 Mastic - Beneath Mat. #4 - Yellow
None Detected107079 AB13-Interior - Main Room - Adj Desk
6 Floor Tile - 12X12 - Top Layer - Blue
None Detected107079 AB14-Interior - Flotatin Room - SE Corner
7 Mastic - Beneath Mat #6 - Yellow
None Detected107079 AB15-Interior - Flotatin Room - SE Corner
Appendix A - Asbestos Results, Pg. 1 DGM Project # 107079
8 Floor Tile - Bottom Layer - White
None Detected107079 AB16-Interior - Flotatin Room - SE Corner
9 Mastic - Beneath Mat. #8 - Gray
None Detected107079 AB17-Interior - Flotatin Room - SE Corner
10 Mastic - Behind Base Cove - White
None Detected107079 AB18-Interior - Main Room - Adj Desk
11 Floor Tile - 12X12 - Black Specled - White
None Detected107079 AB19-Interior - Entrance Hallway - Adj Door to Exterior
12 Ceiling Tile - 2X4 Medium Pock -
None Detected107079 AB20-Interior - Main Room - Center
13 Texture - Atop Cinder Block -
None Detected107079 AB21-Interior - Rest Room 2 - SW Corner
None Detected107079 AB22-Interior - Floatation Room - NW Corner
None Detected107079 AB23-Interior - Rest Room 1 - NW Corner
14 Plaster - Atop Cinder Block -
None Detected107079 AB24-Interior - Rest Room 3 - NE Corner
None Detected107079 AB25-Interior - Rest Room 3 - S - Center
None Detected107079 AB26-Interior - Rest Room 4 - S - Center
15 Stucco - Exterior Plaster -
None Detected107079 AB27-Exterior - S Side - E - End
None Detected107079 AB28-Exterior - N Side - W - End
None Detected107079 AB29-Exterior - W Side - S End
16 Roof - Asphalt - Black
None Detected107079 AB30-Exterior - Roof - NW Roof
17 Tar Paper - Beneath Roof Shingle - Black
None Detected107079 AB31-Exterior - Roof - NW Roof
Appendix A - Asbestos Results, Pg. 2 DGM Project # 107079
18 Built-Up-Roof - Beneath Stone - Black
None Detected107079 AB32-Exterior - Pitched Roof - Adj NW Roof
19 Mastic - On Pipe Penetration - Black
None Detected107079 AB33-Exterior - Pitched Roof - Adj NW Roof
20 Mastic - On Flashing - Black
10% Chrysotile107079 AB34-Exterior - Pitched Roof - Adj NW Roof
21 Built-Up-Roof - Beneath Stone - Black
8% Chrysotile107079 AB35-Exterior - E Roof - SE Corner
22 Putty - On Window - Black
None Detected107079 AB36-Exterior - - S - Center
Appendix A - Asbestos Results, Pg. 3 DGM Project # 107079
Dustin Highlight
Dustin Highlight
Dustin Highlight
Dustin Highlight
Lead Sample Results
Description Sample ID Weight %
The following table provides an inventory of the suspect lead based paint identified during DGM's inspection of the subject site.. The table provides each of the materials unique sample identification number and corresponding laboratory result.
PPM
Below Reportable LimitsBeige Sheet Rock Wall 107079 L1-
Interior- Main Room - E - Center
Beige Cinder Block Wall 107079 L2- 0.147 1470
Interior- Main Room - SW Corner
Brown Metal Door Frame 107079 L3- 0.212 2120
Interior- Main Room - Adj SW Bathroom
Below Reportable LimitsBrown Metal Door 107079 L4-
Interior- Main Room - S Door
Below Reportable LimitsBrown Metal Door Frame 107079 L5-
Interior- Main Room - Door to Back Hall
Below Reportable LimitsBeige Ceramic Floor 107079 L6-
Interior- Kitchen - NW Corner
Below Reportable LimitsDark Brown Metal Rail 107079 L7-
Interior- Entrance Hallway - Adj Door to Exterior
Beige Metal Column 107079 L8- 1.394 13940
Interior- Main Room - SE Corner
Brown Metal Door - 6 Panel 107079 L9- 0.023 230
Interior- Main Room - Door to Back Hallway
Below Reportable LimitsBeige Metal Roll Door Frame 107079 L10-
Exterior- E Side - Mechanical Room Door
Below Reportable LimitsRed Metal Facia 107079 L11-
Exterior- Roof - N - Center
Beige Cinder Block Wall 107079 L12- 0.005 50
Interior- Mechanical Room - S Wall
Appendix A.2 - Lead Results, Pg. 1 DGM Project # 107079
Dustin Highlight
Dustin Highlight
Dustin Highlight
Dustin Highlight
Dustin Highlight
Dustin Highlight
Dustin Highlight
Dustin Highlight
Description Sample ID Weight % PPM
Beige Metal Pipe 107079 L13- 0.050 500
Interior- Mechanical Room - SW Corner
Off-White Metal Louver 107079 L14- 0.022 220
Interior- Mechanical Room - NW Corner
Tan Metal Louver 107079 L15- 0.043 430
Exterior- E Side - Adj Mech Room
Below Reportable LimitsBeige Metal Window Frame 107079 L16-
Interior- Main Room - S Wall
Below Reportable LimitsBeige Concrete Stairs 107079 L17-
Exterior- W Side - S End
Red Metal Hand Rail 107079 L18- 0.359 3590
Exterior- S Side - E End
Below Reportable LimitsBeige Metal Down Spout 107079 L19-
Exterior- E Side - N End
Below Reportable LimitsBeige Metal HVAC Unit 107079 L20-
Exterior- W Side - Center
Appendix A.2 - Lead Results, Pg. 2 DGM Project # 107079
Dustin Highlight
Dustin Highlight
Sample Location Diagram
* Diagram Not Drawn To Scale
Asbestos Survey
NAFB Bldg. 10250
Job #107.079
Appendix B
AB3
Day Care Entrance Hallway
Floatation Room
Kithcen
Back Hallway
RR1
RR2
RR3
RR4
Mech Room
AB1AB2
Main Room
Desk
AB4
AB5
AB6
Office 2
Office 1AB7
AB8
AB9
AB10AB11 AB12AB13
AB14
AB15
AB16
AB17
AB18
AB19AB20
AB21
AB22
AB23
AB24AB25 AB26 AB27
AB28
AB29
AB36
Drawn To Scale
Lead
NAFB Bldg. 10250
Job #107.079
Appendix B
Day Care Entrance Hallway
Floatation Room
Kithcen
Back Hallway
RR1
RR2
RR3
RR4
Mech Room
L1
L2 L3 L4
L5
L6
L7
L8
L9
L10
Office 1
Office 2
L12L13L14
L15
L16
L17
L18
L19
L20
Dustin Highlight
Dustin Highlight
Dustin Highlight
Drawn To Scale
Asbestos & Lead Survey
NAFB Bldg. 10250
Job #107.079
Appendix B
Roof
AB32
AB30
Pitched Roof
NW
Roof
E Roof
AB31
AB33
AB34
AB35
L11
Dustin Highlight
File details come from the government source that posted it. Updated .