About this file
This document is an Asbestos and Lead Based Paint Inspection Report for Nellis Air Force Base, specifically for Building 10250, focused on restroom renovation in the east corner. Macrotec Consulting, LLC performed comprehensive testing on August 2, 2023, examining multiple building materials including wall substrates, drywall texture, concrete surfaces, base coves, floor coatings, and sink caulk. The laboratory analysis by Triangle Environmental Service Center utilized Polarized Light Microscopy (PLM) and X-Ray Fluorescence (XRF) testing methods, with all 14 samples returning "No Asbestos Detected" and no lead detected across tested surfaces. The work order (RKMF240010) specifically scopes renovating restrooms in the east corner, and the report emphasizes that only proper personnel should interpret the results for current and future renovation activities.
View the file
Other files
Show 40 more
Latest 50 of 126 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report
Work Order Scope of Work:
Renovate restrooms in east corner of building.
Building Number: 10250
Inspection Date: 8/2/2023
Nellis Work Order: RKMF240010
Macrotec Job Number: 23766
The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building.
Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.
Introduction:
Report Limitations:
Office@MacrotecConsulting.com Phone: (702) 949-6225 Fax: (702) 629-5677
Appendix A - Asbestos Assessment
Macrotec Job #23766 - Bldg. 10250 ; RKMF240010
The following table lists each of the materials suspected to contain asbestos at the subject site. For each material the sample number, location and laboratory result are listed. If the material was found to contain asbestos, the friablity and NESHAP classification is identified.
1 Wall Substrate (Drywall & Mud) - No Asbestos Detected
None DetectedEast Corner - Men's Room - W cornerAB1
None DetectedEast Corner - Women's Room - W cornerAB2
None DetectedEast Corner - Women's Room - E cornerAB3
2 Texture on Drywall - No Asbestos Detected
None DetectedEast Corner - Women's Room - NW wallAB4
None DetectedEast Corner - Men's Room - SE wallAB5
None DetectedEast Corner - Men's Room - NW wallAB6
3 Texture on Concrete - No Asbestos Detected
None DetectedEast Corner - Men's Room - NE wallAB7
None DetectedEast Corner - Men's Room - SE wallAB8
None DetectedEast Corner - Women's Room - NE wallAB9
4 Gray Base Cove - No Asbestos Detected
None DetectedEast Corner - Men's Room - NE wallAB10
5 Yellow Base Cove Mastic - No Asbestos Detected
None DetectedEast Corner - Men's Room - NE wallAB11
6 Coating on Concrete Floor - No Asbestos Detected
None DetectedEast Corner - Women's Room - N cornerAB12
Asbestos Survey
Bldg. 10250
Macrotec Job #23766
Appendix A
7 Concrete Sub Floor - No Asbestos Detected
None DetectedEast Corner - Women's Room - N cornerAB13
8 Caulk on Sink - No Asbestos Detected
None DetectedEast Corner - Men's Room - SE wallAB14
Asbestos Survey
Bldg. 10250
Appendix B - Lead Assessment
Macrotec conducted analysis of the painted surfaces and/or bulk materials that may be impacted during the defined scope of work, using an XRF analyzer. No lead was detected during the inspection of the suspect materials. Appendix E lists the painted surfaces that were analyzed during this inspection along with its location and analysis result. Note: If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.
Lead Paint Inspection Bldg. 10250
Appendix B
Asbestos & Lead Based Paint Inspection
NAFB—Bldg. 10250
Macrotec Project # 23766
Appendix C
Sample Location Diagram
N
AB3
AB2
AB1
AB8
AB7
AB6
AB5
AB4
AB10
AB9
AB14
AB13
AB12
AB11
Men’s Room
Women’s Room
Macrotec Consulting
TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.
13509 East Boundary Road, Suite B, Midlothian, VA 23112
804-739-1751 • fax: 804-739-1753
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
23766
Bldg. 10250
230803AB
8/3/2023
8/4/2023
8/4/2023
B. TrimmerJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB/ #:
1A AB 1 - Drywall / White Powder Brown Fibers NAD 80%20% Cellulose
1B Mud / White Powder NAD 100%
2A AB 3 - Drywall / White Powder Brown Fibers NAD 80%20% Cellulose
2B Mud / White Powder NAD 100%
3A AB 3 - Drywall / White Powder Brown Fibers NAD 80%20% Cellulose
3B mud / White Powder NAD 100%
4 AB 4 / White Powder NAD 100%
5 AB 5 / White Powder NAD 100%
6 AB 6 / White Powder NAD 100%
Friday, August 4, 2023 Page 1 of 2
Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993
(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Sodium Chloride is analyzed for quality control blank. TESC recommends by point count or
Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested. This repo r t may no t be u sed by the c l i en t to c la im p roduc t endorsement by NVLAP or any o ther agency o f the U.S . Government .
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
Macrotec Consulting
TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.
13509 East Boundary Road, Suite B, Midlothian, VA 23112
804-739-1751 • fax: 804-739-1753
BULK ASBESTOS SAMPLE ANALYSIS SUMMARY
9724 Mild Weather Ct.
Las Vegas, NV 89148
23766
Bldg. 10250
230803AB
8/3/2023
8/4/2023
8/4/2023
B. TrimmerJOB SITE:
TESC LOGIN #:
DATE OF RECEIPT:
DATE OF ANALYSIS:
DATE OF REPORT:
ANALYST:
TESC
SAMPLE #
CLIENT SAMPLE ID
& GROSS DESCRIPTION
ESTIMATED
% ASBESTOS
NON ASBESTOS
% FIBERS
NON FIBROUS
% MATERIALS
CLIENT:
CLIENT JOB/ #:
7 AB 7 / White Powder NAD 100%
8 AB 8 / White Powder NAD 100%
9 AB 9 / White Powder NAD 100%
10 AB 10 / Grey Rubber NAD 100%
11 AB 11 / Yellow Adhesive NAD 100%
12 AB 12 / Blue Epoxy NAD 100%
13 AB 13 / Grey Granular NAD 100%
14 AB 14 / White Adhesive NAD 100%
Total Samples/Layers Analyzed: 17
Friday, August 4, 2023 Page 2 of 2
Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993
(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Sodium Chloride is analyzed for quality control blank. TESC recommends by point count or
Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested. This repo r t may no t be u sed by the c l i en t to c la im p roduc t endorsement by NVLAP or any o ther agency o f the U.S . Government .
NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [
Reviewed By Authorized Signatory:
Feng Jiang, MS Senior Geologist, Laboratory Director
Yuedong Fang, Senior Geologist
Macrotec Bulk Sampling Ghain of Custody Form client Name NAFB
Project Name Bldq' 7O25O ; RK4F24OOTO
Project Location Bldg' 7O25O
Technician Jason R lllcfillister -fF--
Laboratory I E>L
Stop at 1st Positive?: Y / N Composite Wall Substrate?: Y / N
Project Number
Collection Date
WO Number
23766 8/2/2023
Turn Around Time
Method of Analysis
Matrix Eulk
3 Day
PLM
Sample # H # lCount
Sample Description (Material Type : Color / Description)
Sample Location (General: Room : Specific)
7 last Uall Substrate (Drywall & //lud) - East Corner' /l/len's Room - U corner r lnsz Uall Substrate (Drywall & lflud) - East Corner - Uomen's Room - U corner r lnss It Substrate (Drywatt & //lud) - East Corner - Nomen's Room - E corner
2 las+ Texture on Drywall - East Corner - Nomen's Room - Ntl wqll
2 lass Texture on Drywall - East Corner - //len's Room ' 5E wall
2 lasa Texture on Drywall - East Corner - fllen's Room - NW wall s lasz Texture on Concrete - East Corner - /l4en's Room - NE wall
3 lass Texture on Concrete - East Corner - //len's Room - 5E wall
3 lass Texture on Concrete' East Corner - Women's Room - NE wall
+ to 6ray Base Cove - East Corner - lllen's Room - NE wall
5 lasn Yellow Ease Cove lllastic - East Corner - fl/len's Room - NE wall
6lasrz Coating on Concrete Floor - Easb Corner - Uomen's Room - N corner
7 lnsrc Concrete Sub Floor - East Corner - Women's Room - N corner s lasrc Caulk on Sink - East Corner - ll4en's Room - 5E wall
Received By:
Received By:
yc:28at
XRF Data Table
Date Time Component Substrate Color Area Room Side Result Conc. NomSecs 3 SD 8/2/2023 15:30:14 Wall Concrete White E Corner Men's Room A Negative 0 1 0.3 8/2/2023 15:30:27 Wall Concrete White E Corner Men's Room B Negative 0.1 2 0.3 8/2/2023 15:30:46 Wall Drywall White E Corner Men's Room C Negative 0.1 2 0.2 8/2/2023 15:31:02 Wall Drywall White E Corner Men's Room D Negative 0.2 2 0.3 8/2/2023 15:31:18 Ceiling Drywall White E Corner Men's Room Negative 0.1 2 0.3 8/2/2023 15:31:41 Floor Concrete Gray E Corner Men's Room Negative 0.1 1 0.3 8/2/2023 15:32:13 Sink Porcelain White E Corner Men's Room B Negative 0.2 1 0.3 8/2/2023 15:32:37 Door Metal Gray E Corner Men's Room C Negative 0.1 2 0.2 8/2/2023 15:33:06 Doorframe Wood Gray E Corner Men's Room C Negative 0.1 2 0.2 8/2/2023 15:33:13 Doorframe Wood Gray E Corner Men's Room C Negative 0.2 2 0.2 8/2/2023 15:33:22 Doorframe Wood Gray E Corner Men's Room C Negative 0.1 2 0.2 8/2/2023 15:33:38 Doorframe Wood Gray E Corner Women's Rm C Negative 0.1 2 0.2 8/2/2023 15:33:46 Doorframe Wood Gray E Corner Women's Rm C Negative 0.2 1 0.3 8/2/2023 15:34:14 Door Metal Gray E Corner Women's Rm C Negative 0.1 2 0.2 8/2/2023 15:34:33 Wall Drywall White E Corner Women's Rm C Negative 0.2 2 0.2 8/2/2023 15:34:46 Wall Drywall White E Corner Women's Rm D Negative 0.1 2 0.2 8/2/2023 15:34:59 Wall Concrete White E Corner Women's Rm D Negative 0.1 2 0.3 8/2/2023 15:35:15 Wall Concrete White E Corner Women's Rm A Negative 0 1 0.3 8/2/2023 15:35:30 Wall Drywall White E Corner Women's Rm B Negative 0.1 2 0.2 8/2/2023 15:35:44 Ceiling Drywall White E Corner Women's Rm Negative 0.1 2 0.3 8/2/2023 15:36:05 Floor Concrete Gray E Corner Women's Rm Negative 0 1 0.3 8/2/2023 15:36:27 Base Cove Vinyl Gray E Corner Women's Rm B Negative 0 2 0.2 8/2/2023 15:36:55 Sink Porcelain White E Corner Women's Rm A Negative 0.2 1 0.3 8/2/2023 15:37:09 Toilet Porcelain White E Corner Women's Rm A Negative 0 2 0.3 8/2/2023 15:37:55 Calibration Positive 1.1 5 0.1 8/2/2023 15:38:06 Calibration Positive 1.1 5 0.1 8/2/2023 15:38:18 Calibration Positive 1.1 5 0.1