(Attachment 56) SABER Seed SOO Honor Guard Building 10250 Attachment 2- HAZMAT Results 10250 Restrooms part 2.pdf

PDF 499 KB Posted

Attached to
SABER IDIQ
Solicitation number
FA486125R0003
Issued by

About this file

This document is an Asbestos and Lead Based Paint Inspection Report for Nellis Air Force Base, specifically for Building 10250, focused on restroom renovation in the east corner. Macrotec Consulting, LLC performed comprehensive testing on August 2, 2023, examining multiple building materials including wall substrates, drywall texture, concrete surfaces, base coves, floor coatings, and sink caulk. The laboratory analysis by Triangle Environmental Service Center utilized Polarized Light Microscopy (PLM) and X-Ray Fluorescence (XRF) testing methods, with all 14 samples returning "No Asbestos Detected" and no lead detected across tested surfaces. The work order (RKMF240010) specifically scopes renovating restrooms in the east corner, and the report emphasizes that only proper personnel should interpret the results for current and future renovation activities.

View the file

Other files

File Type Posted
Solicitation Amendment FA486125R00030017 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030017.pdf PDF
Atch 80_ RFI Response Log_General Solicitation 9 March 2026.xlsx XLSX spreadsheet
Solicitation Amendment FA486125R00030016 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030016.pdf PDF
Solicitation Amendment - FA486125R00030015.pdf PDF
Solicitation Amendment FA486125R00030015 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030014.pdf PDF
3 - Self Scoring Matrix 17 Feb 26.xlsx XLSX spreadsheet
Solicitation Amendment FA486125R00030014 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030013.pdf PDF
Solicitation Amendment FA486125R00030013 SF 30.pdf PDF
Attach 79 RFI Log SABER Seed 29 Jan 2026_.xlsx XLSX spreadsheet
Att 78 RFI Log Additional Responses General Solicitation 27 Jan 2026_.xlsx XLSX spreadsheet
Att 3 -Self Scoring Matrix 3_Feb_2026.xlsx XLSX spreadsheet
44- SABER SOO RKMF240010 Renovate Honor Guard 99 FSS B10250_28January2026 (003).pdf PDF
Solicitation Amendment FA486125R00030012 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030012.pdf PDF
Solicitation Amendment FA486125R00030011 SF 30 .pdf PDF
1 - SABER SOW 7 Jan 2026.pdf PDF
Solicitation Amendment - FA486125R00030011.pdf PDF
2 - Price Schedule _13 Jan 2026.xlsx XLSX spreadsheet
3 - Self Scoring Matrix 7_Jan 26.xlsx XLSX spreadsheet
77 - RFI Response Log SABER Seed Related _ 13_Jan 2026.xlsx XLSX spreadsheet
Solicitation Amendment - FA486125R00030010.pdf PDF
44 -Statement of Objectives (SOO) for RKMF 240010 20 Nov 25.pdf PDF
Attach 75 SABER Seed Attachment 19 - B10250 comm room.pdf PDF
Attach 74 SABER Seed Attachment 18 - Knox Box Location.pdf PDF
73 - Task Order Pricing Letter _ Gordian System Licens Fees 5 percent and 1.95 percent.pdf PDF
1- SABER SOW 7 Jan 2025 .pdf PDF
76 - RFI Response Log General Solicitation 13_Jan 26.xlsx XLSX spreadsheet
Solicitation Amendment FA486125R00030010 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030009.pdf PDF
Solicitation Amendment FA486125R00030009_SF 30.pdf PDF
Solicitation Amendment FA486125R00030007 SF 30.pdf PDF
Solicitation Amendment FA486125R00030006 SF 30.pdf PDF
(Attachment 65) SABER Seed SOO Honor Guard Building 10250 Attachment 12 - Mech. Room Report.pdf PDF
(Attachment 66) SABER Seed SOO Honor Guard Building 10250 Attachment 13 - Asbestos and Lead testing building history.xlsx XLSX spreadsheet
Solicitation Amendment - FA486125R00030006.pdf PDF
Attachment 72 SABER IDIQ Preproposal Sign In Sheet 29 October 2025 FA486125R0003.pdf PDF
(Attachment 63) SABER Seed SOO Honor Guard Building 10250 Attachment 10 - Asbestos and Lead testing dated 24 February 2014.pdf PDF
(Attachment 68) SABER Seed SOO Honor Guard Building 10250 Attachment 15 - B10250 room numbers.pdf PDF
(Attachment 55) SABER Seed SOO Honor Guard Building 10250 Attachment 1 - HAZMAT Results 10250 Restrooms Part 1.pdf PDF
(Attachment 58) SABER Seed SOO Honor Guard Building 10250 Attachment 5 - Attachment 5 AFGIMS Utilities Snapshot.pdf PDF
(Attachment 69) SABER Seed SOO Honor Guard Building 10250 Attachment 16 - 10250 BFP Device replacement.png PNG image
(Attachment 57) SABER Seed SOO Honor Guard Building 10250 Attachment 3 - As-Builts 65 LOCATION and GRADING.pdf PDF
(Attachment 70) SABER Seed SOO Honor Guard Building 10250 Attachment 17 - Double Check Valve Assembly.pdf PDF
(Attachment 60) SABER Seed SOO Honor Guard Building 10250 Attachment 7 - Sewer Line with Measurements and Pictures.pdf PDF
Attachment 71 SABER IDIQ Preproposal Conference Slides 29 October 2025 FA486125R0003.pptx PPTX presentation
(Attachment 61) SABER Seed SOO Honor Guard Building 10250 Attachment 8 - Asbestos and Lead testing of entire building dated 7 July 2007.pdf PDF
Show 40 more

Latest 50 of 126 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Nellis Air Force Base Asbestos and Lead Based Paint Inspection Report

Work Order Scope of Work:

Renovate restrooms in east corner of building.

Building Number: 10250

Inspection Date: 8/2/2023

Nellis Work Order: RKMF240010

Macrotec Job Number: 23766

The information contained in this report pertains only to the specific area defined in the above scope of work. This summarized report is for reference purposes, only. A detailed generic report is on file with Nellis Air Force Base Civil Engineering. Only proper personnel should interpret this report to determine whether the information herein can be utilized for current and future renovation activities within the building.

Macrotec Consulting, LLC. performed an inspection for Asbestos Containing Building Materials and Lead Based Paint. The intent of this inspection was to identify materials containing asbestos and lead, within the subject site, that may be impacted during planned renovation activities.

Introduction:

Report Limitations:

Office@MacrotecConsulting.com Phone: (702) 949-6225 Fax: (702) 629-5677

Appendix A - Asbestos Assessment

Macrotec Job #23766 - Bldg. 10250 ; RKMF240010

The following table lists each of the materials suspected to contain asbestos at the subject site. For each material the sample number, location and laboratory result are listed. If the material was found to contain asbestos, the friablity and NESHAP classification is identified.

1 Wall Substrate (Drywall & Mud) - No Asbestos Detected

None DetectedEast Corner - Men's Room - W cornerAB1

None DetectedEast Corner - Women's Room - W cornerAB2

None DetectedEast Corner - Women's Room - E cornerAB3

2 Texture on Drywall - No Asbestos Detected

None DetectedEast Corner - Women's Room - NW wallAB4

None DetectedEast Corner - Men's Room - SE wallAB5

None DetectedEast Corner - Men's Room - NW wallAB6

3 Texture on Concrete - No Asbestos Detected

None DetectedEast Corner - Men's Room - NE wallAB7

None DetectedEast Corner - Men's Room - SE wallAB8

None DetectedEast Corner - Women's Room - NE wallAB9

4 Gray Base Cove - No Asbestos Detected

None DetectedEast Corner - Men's Room - NE wallAB10

5 Yellow Base Cove Mastic - No Asbestos Detected

None DetectedEast Corner - Men's Room - NE wallAB11

6 Coating on Concrete Floor - No Asbestos Detected

None DetectedEast Corner - Women's Room - N cornerAB12

Asbestos Survey

Bldg. 10250

Macrotec Job #23766

Appendix A

7 Concrete Sub Floor - No Asbestos Detected

None DetectedEast Corner - Women's Room - N cornerAB13

8 Caulk on Sink - No Asbestos Detected

None DetectedEast Corner - Men's Room - SE wallAB14

Asbestos Survey

Bldg. 10250

Appendix B - Lead Assessment

Macrotec conducted analysis of the painted surfaces and/or bulk materials that may be impacted during the defined scope of work, using an XRF analyzer. No lead was detected during the inspection of the suspect materials. Appendix E lists the painted surfaces that were analyzed during this inspection along with its location and analysis result. Note: If suspect materials are found during renovation activities outside what was identified in this report, stop work immediately until further testing can be completed.

Lead Paint Inspection Bldg. 10250

Appendix B

Asbestos & Lead Based Paint Inspection

NAFB—Bldg. 10250

Macrotec Project # 23766

Appendix C

Sample Location Diagram

N

AB3

AB2

AB1

AB8

AB7

AB6

AB5

AB4

AB10

AB9

AB14

AB13

AB12

AB11

Men’s Room

Women’s Room

Macrotec Consulting

TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.

13509 East Boundary Road, Suite B, Midlothian, VA 23112

804-739-1751 • fax: 804-739-1753

BULK ASBESTOS SAMPLE ANALYSIS SUMMARY

9724 Mild Weather Ct.

Las Vegas, NV 89148

23766

Bldg. 10250

230803AB

8/3/2023

8/4/2023

8/4/2023

B. TrimmerJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

CLIENT JOB/ #:

1A AB 1 - Drywall / White Powder Brown Fibers NAD 80%20% Cellulose

1B Mud / White Powder NAD 100%

2A AB 3 - Drywall / White Powder Brown Fibers NAD 80%20% Cellulose

2B Mud / White Powder NAD 100%

3A AB 3 - Drywall / White Powder Brown Fibers NAD 80%20% Cellulose

3B mud / White Powder NAD 100%

4 AB 4 / White Powder NAD 100%

5 AB 5 / White Powder NAD 100%

6 AB 6 / White Powder NAD 100%

Friday, August 4, 2023 Page 1 of 2

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993

(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Sodium Chloride is analyzed for quality control blank. TESC recommends by point count or

Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested. This repo r t may no t be u sed by the c l i en t to c la im p roduc t endorsement by NVLAP or any o ther agency o f the U.S . Government .

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

Feng Jiang, MS Senior Geologist, Laboratory Director

Yuedong Fang, Senior Geologist

Macrotec Consulting

TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC.

13509 East Boundary Road, Suite B, Midlothian, VA 23112

804-739-1751 • fax: 804-739-1753

BULK ASBESTOS SAMPLE ANALYSIS SUMMARY

9724 Mild Weather Ct.

Las Vegas, NV 89148

23766

Bldg. 10250

230803AB

8/3/2023

8/4/2023

8/4/2023

B. TrimmerJOB SITE:

TESC LOGIN #:

DATE OF RECEIPT:

DATE OF ANALYSIS:

DATE OF REPORT:

ANALYST:

TESC

SAMPLE #

CLIENT SAMPLE ID

& GROSS DESCRIPTION

ESTIMATED

% ASBESTOS

NON ASBESTOS

% FIBERS

NON FIBROUS

% MATERIALS

CLIENT:

CLIENT JOB/ #:

7 AB 7 / White Powder NAD 100%

8 AB 8 / White Powder NAD 100%

9 AB 9 / White Powder NAD 100%

10 AB 10 / Grey Rubber NAD 100%

11 AB 11 / Yellow Adhesive NAD 100%

12 AB 12 / Blue Epoxy NAD 100%

13 AB 13 / Grey Granular NAD 100%

14 AB 14 / White Adhesive NAD 100%

Total Samples/Layers Analyzed: 17

Friday, August 4, 2023 Page 2 of 2

Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA/600/R-93-116, July 1993

(EPA-600/M4-82-020, Dec 1982), or the current US EPA method for the analysis of asbestos in building material. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Sodium Chloride is analyzed for quality control blank. TESC recommends by point count or

Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report must not be reproduced except in full with approval of Triangle Environmental Service Center, Inc. This test report relates only to the item(s) tested. This repo r t may no t be u sed by the c l i en t to c la im p roduc t endorsement by NVLAP or any o ther agency o f the U.S . Government .

NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [

Reviewed By Authorized Signatory:

Feng Jiang, MS Senior Geologist, Laboratory Director

Yuedong Fang, Senior Geologist

Macrotec Bulk Sampling Ghain of Custody Form client Name NAFB

Project Name Bldq' 7O25O ; RK4F24OOTO

Project Location Bldg' 7O25O

Technician Jason R lllcfillister -fF--

Laboratory I E>L

Stop at 1st Positive?: Y / N Composite Wall Substrate?: Y / N

Project Number

Collection Date

WO Number

23766 8/2/2023

Turn Around Time

Method of Analysis

Matrix Eulk

3 Day

PLM

Sample # H # lCount

Sample Description (Material Type : Color / Description)

Sample Location (General: Room : Specific)

7 last Uall Substrate (Drywall & //lud) - East Corner' /l/len's Room - U corner r lnsz Uall Substrate (Drywall & lflud) - East Corner - Uomen's Room - U corner r lnss It Substrate (Drywatt & //lud) - East Corner - Nomen's Room - E corner

2 las+ Texture on Drywall - East Corner - Nomen's Room - Ntl wqll

2 lass Texture on Drywall - East Corner - //len's Room ' 5E wall

2 lasa Texture on Drywall - East Corner - fllen's Room - NW wall s lasz Texture on Concrete - East Corner - /l4en's Room - NE wall

3 lass Texture on Concrete - East Corner - //len's Room - 5E wall

3 lass Texture on Concrete' East Corner - Women's Room - NE wall

+ to 6ray Base Cove - East Corner - lllen's Room - NE wall

5 lasn Yellow Ease Cove lllastic - East Corner - fl/len's Room - NE wall

6lasrz Coating on Concrete Floor - Easb Corner - Uomen's Room - N corner

7 lnsrc Concrete Sub Floor - East Corner - Women's Room - N corner s lasrc Caulk on Sink - East Corner - ll4en's Room - 5E wall

Received By:

Received By:

yc:28at

XRF Data Table

Date Time Component Substrate Color Area Room Side Result Conc. NomSecs 3 SD 8/2/2023 15:30:14 Wall Concrete White E Corner Men's Room A Negative 0 1 0.3 8/2/2023 15:30:27 Wall Concrete White E Corner Men's Room B Negative 0.1 2 0.3 8/2/2023 15:30:46 Wall Drywall White E Corner Men's Room C Negative 0.1 2 0.2 8/2/2023 15:31:02 Wall Drywall White E Corner Men's Room D Negative 0.2 2 0.3 8/2/2023 15:31:18 Ceiling Drywall White E Corner Men's Room Negative 0.1 2 0.3 8/2/2023 15:31:41 Floor Concrete Gray E Corner Men's Room Negative 0.1 1 0.3 8/2/2023 15:32:13 Sink Porcelain White E Corner Men's Room B Negative 0.2 1 0.3 8/2/2023 15:32:37 Door Metal Gray E Corner Men's Room C Negative 0.1 2 0.2 8/2/2023 15:33:06 Doorframe Wood Gray E Corner Men's Room C Negative 0.1 2 0.2 8/2/2023 15:33:13 Doorframe Wood Gray E Corner Men's Room C Negative 0.2 2 0.2 8/2/2023 15:33:22 Doorframe Wood Gray E Corner Men's Room C Negative 0.1 2 0.2 8/2/2023 15:33:38 Doorframe Wood Gray E Corner Women's Rm C Negative 0.1 2 0.2 8/2/2023 15:33:46 Doorframe Wood Gray E Corner Women's Rm C Negative 0.2 1 0.3 8/2/2023 15:34:14 Door Metal Gray E Corner Women's Rm C Negative 0.1 2 0.2 8/2/2023 15:34:33 Wall Drywall White E Corner Women's Rm C Negative 0.2 2 0.2 8/2/2023 15:34:46 Wall Drywall White E Corner Women's Rm D Negative 0.1 2 0.2 8/2/2023 15:34:59 Wall Concrete White E Corner Women's Rm D Negative 0.1 2 0.3 8/2/2023 15:35:15 Wall Concrete White E Corner Women's Rm A Negative 0 1 0.3 8/2/2023 15:35:30 Wall Drywall White E Corner Women's Rm B Negative 0.1 2 0.2 8/2/2023 15:35:44 Ceiling Drywall White E Corner Women's Rm Negative 0.1 2 0.3 8/2/2023 15:36:05 Floor Concrete Gray E Corner Women's Rm Negative 0 1 0.3 8/2/2023 15:36:27 Base Cove Vinyl Gray E Corner Women's Rm B Negative 0 2 0.2 8/2/2023 15:36:55 Sink Porcelain White E Corner Women's Rm A Negative 0.2 1 0.3 8/2/2023 15:37:09 Toilet Porcelain White E Corner Women's Rm A Negative 0 2 0.3 8/2/2023 15:37:55 Calibration Positive 1.1 5 0.1 8/2/2023 15:38:06 Calibration Positive 1.1 5 0.1 8/2/2023 15:38:18 Calibration Positive 1.1 5 0.1

NAFB - Building 10250 Macrotec Job #23766 Appendix E