This document is a facility assessment file containing asbestos data archives, facility condition reports, and real property inventory information for Building 49800 (Heavy Equipment Shop) at Cape Canaveral Air Force Station (CCAFS).
Building 49800 is a 5,526 square foot structure constructed in 1959 with a concrete foundation, corrugated metal walls and roof, and six roll-up bay doors, partitioned into three high-bays. The facility was used by SpecPro Environmental Services for storing heavy equipment, vehicles, tools, and chemicals for forestry services and invasive plant control. The Asbestos Data Archive indicates that Room 2 contains friable asbestos-containing materials (ACM) in wall tile covering (144 SF) and fibrous board panels (144 SF), along with non-friable floor mastic (72 SF). Rooms 3, 4, and 5 contain only non-friable ACM in silver paint wall coverings and black expansion joints. Sample testing from 1992 and 2005 across all rooms returned "NAD" (No Asbestos Detected) results with 0% asbestos content. The May 2016 Facility Condition Assessment rated the building in very poor condition with a Building Condition Index of 66 (Red), noting that utilities have been decommissioned and the facility is vacant. Deficiencies identified include roof leaks at various locations, one inoperable roll-up door shifted from its guide, and a compressed air system hose reel leak. Project DBEH111638 scheduled the building for demolition in FY2018, with no active Deferred Scheduled Work orders recommended. The facility is listed as historic and requires real property inventory updates every three years, with the last inventory completed in 2016.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Installatio DBEH
AMIS Asbestos Data Archive
Building Number 49800 HEAVY EQUIPMENT SHOP
DescriptionGroup Name
ACM
Code
FriableACM Presen
Room Number / Name 2
Quantity Units
N YWT Wall Covering (Tile) 12" LARGE AND
MEDIUM HOLES
144 SF
N YWP Wall Covering (Panel)
BROWN FIBROUS
BOARD
144 SF
N NFM Floor Covering (Mastic)
WHITE CARPET
ADHESIVE
72 SF
DescriptionGroup Name
ACM
Code
FriableACM Presen
Room Number / Name 3
Quantity Units
N NWA Wall Covering (Alumicote)
SILVER PAINT 1296 SF
N NFE Floor Covering (Expansion joint)
BLACK 200 LF
DescriptionGroup Name
ACM
Code
FriableACM Presen
Room Number / Name 4
Quantity Units
N NWA Wall Covering (Alumicote)
SILVER PAINT 1350 SF
N NFE Floor Covering (Expansion joint)
BLACK 240 LF
DescriptionGroup Name
ACM
Code
FriableACM Presen
Room Number / Name 5
Quantity Units
N NWA Wall Covering (Alumicote)
SILVER PAINT 2460 SF
N NFE Floor Covering (Expansion joint)
BLACK 220 LF
Not Valid For Design Or Decision Making
AMIS Asbestos Sample Results Archive
Building Number 49800
CommentsGroup Name
ACM
Code
ACM
2 Type
ACM
Percen
Room Number / Name ROOM 2
ACM
Type
ACM 2
Percen
Sample Number
Sample Date
0FM01 Floor Covering (Mastic)
NAD 0CHS2918 4/7/2005
0FM01 Floor Covering (Mastic)
NAD 0CHS2919 4/7/2005
0FM01 Floor Covering (Mastic)
NAD 0CHS2920 4/7/2005
0WP01 Wall Covering (Panel)
NAD 0BOC2439 6/30/1992
0WP01 Wall Covering (Panel)
NAD 0BOC2440 6/30/1992
0WP01 Wall Covering (Panel)
NAD 0BOC2441 6/30/1992
0WT01 Wall Covering (Tile) NAD 0BOC2445 6/30/1992
0WT01 Wall Covering (Tile) NAD 0BOC2446 6/30/1992
0WT01 Wall Covering (Tile) NAD 0BOC2447 6/30/1992
CommentsGroup Name
ACM
Code
ACM
2 Type
ACM
Percen
Room Number / Name ROOM 3
ACM
Type
ACM 2
Percen
Sample Number
Sample Date
0FE01 Floor Covering (Expansion joint)
NAD 0BOC2433 6/30/1992
0WA01 Wall Covering (Alumicote)
NAD 0BOC2430 6/30/1992
CommentsGroup Name
ACM
Code
ACM
2 Type
ACM
Percen
Room Number / Name ROOM 4
ACM
Type
ACM 2
Percen
Sample Number
Sample Date
0FE01 Floor Covering (Expansion joint)
NAD 0BOC2434 6/30/1992
AMIS Asbestos Sample Results Archive
Building Number 49800
CommentsGroup Name
ACM
Code
ACM
2 Type
ACM
Percen
Room Number / Name ROOM 4
ACM
Type
ACM 2
Percen
Sample Number
Sample Date
0WA01 Wall Covering (Alumicote)
NAD 0BOC2431 6/30/1992
CommentsGroup Name
ACM
Code
ACM
2 Type
ACM
Percen
Room Number / Name ROOM 5
ACM
Type
ACM 2
Percen
Sample Number
Sample Date
0FE01 Floor Covering (Expansion joint)
NAD 0BOC2435 6/30/1992
0WA01 Wall Covering (Alumicote)
NAD 0BOC2432 6/30/1992
49800 Facility Condition Assessment
CCAFS IOMS 2009
Facility No: 49800 Fiscal Year: 2009
Facility Name: Heavy Equipment Shop Inspection Date: 4/13/09
Location: CCAFS Industrial Area Facility Owner: USAF
InDyne Maintained Systems/Codes:
Mission Essential Equipment: None Remaining Systems: AC, SR, WP, HT, and AI
OMEU Extract Date:
10/24/07
Inspector(s): Shad Wilson
A. Facility Description/Mission:
Constructed in 1959, Facility 49800 (Heavy Equipment Shop) is a 5,526 square foot (SF) building with a concrete foundation, corrugated metal walls and roof, two metal personnel doors, and six roll-up bay doors. The facility is partitioned with metal walls into three high-bays. The facility is used by SpecPro Environmental Services to store heavy equipment, vehicles, tools, and chemicals used to conduct forestry services and invasive plant control at Cape Canaveral Air Force Station (CCAFS). See Figure 1.
Figure 1. 49800 General View
B. Facility Manager Interview:
Kenneth Burkett, Facility Manager, SpecPro Environmental Services – The facility has problems with rainwater intrusion, but currently meets its assigned mission.
C. Facility/Systems Condition Assessment:
AC: The Electrical Power system meets current mission/function requirements.
o General System Description: The low voltage electrical power system consists of standard low voltage power distribution equipment such as panelboards, disconnect switches, emergency lighting, circuit breakers, conduit, wiring, indoor/outdoor lighting, and receptacles.
o Deficiencies Noted: None o Recommendations: None
SR: The Structural system meets current mission/function requirements.
o General System Description: The structure consists of a poured concrete foundation, corrugated metal walls, a corrugated metal roof, metal personnel doors, and six high-bay roll-up doors. The exterior corrugated metal walls and roof are coated with an elastomeric sealant. The roll-up door is secure and does not need to be operational for the current facility mission.
o Deficiencies Noted: One roll-up door has shifted off its vertical guide and is not operational. The roof leaks rainwater at various locations during heavy rainstorms.
o Recommendations: Generate a Direct Scheduled Work (DSW) project to indentify the roof/wall leaks and perform necessary repairs.
WP: The Potable Water system meets current mission/function requirements.
o General System Description: The potable water system consists of potable lateral piping, two eyewash stations, and exterior water spigots.
o Deficiencies Noted: None o Recommendations: None
AI: The Compressed Air system meets current mission/function requirements.
o General System Description: The compressed air system consists of piping, hose reels, a compressor motor, and compressed air tank.
o Deficiencies noted: A hose reel assembly in the west high-bay leaks air.
o Recommendations: Repair hose reel assembly leak.
HT: The Hoist system meets current mission/function requirements.
o General System Description: The hoist system consists of a one and a half ton electric chain hoist located in the center high-bay.
o Deficiencies Noted: None o Recommendations: None
D. Compliance Issues: None
E. Fixed Ladder Inspection Results: No fixed ladders.
F. Other Observations: Two Potable Water (WP) systems are listed in the OMEU.
G. Summary Tables:
Work Order Action Summary
System Action Work Type
SR
A hose reel assembly in the west high-bay leaks air.
Repair hose reel assembly leak.
DSW
SR
Generate a Direct Scheduled Work (DSW) project to identify the roof/wall leaks and perform necessary repairs.
DSW
Administrative Action Summary
System Action Work Type
WP Delete duplicate WP system in the OMEU. OMEU
Work Order Number: 20463470 Date of Assessment: May 2016
Facility Number Mission Dependency 61
Facility Name Risk Assessment
Score
General Information Sq Ft: 5526 Current Use: VEH MAINT SHOP
Built: 1959 Historic? Yes Organization: VACANT
Condition Information
Building 66 Red Condition Comments:
Systems Facility is in very poor
Exterior 72 Amber condition. Utilities have
Roofing 51 Red been decommissioned.
Interior 74 Amber
Finishes 80 Amber
Plumbing 10 Red
HVAC NA
Fire NA
Electrical 71 Amber
Risk Assessment
Consequence of Failure Relative Scoring MDI x .6
Probability of Failure (POF) Condition Index
The shaded areas of the adjacent chart show probabilities of obtaining funding for SRM projects associated with this facility. The upper right shade shows the best chance for funding as probability and consequence of failure measure mission dependency and condition.
The blue diamond represents the position of risk assessment associated with the building relative to funding probabilities.
Ancillary Inspections and Data
Fixed Ladder Status: Asbestos Status:
Not applicable. No installed ladders. Friable asbestos is not present in the building.
Cross-Connection Status:
Not applicable; no water systems installed.
Real Property Inventory Status:
The last real property inventory was accomplished in 2016. The required three-year cycle of historic facilities, places the next inventory for 2019. However, the field assessment inventory does reconcile with the accountable assets recorded in ACES RP. Book-to-Floor/Floor-to-Book validated.
Corrective Actions - Proposed Work Orders/Projects DBEH111638 demolishes the building in 2018. There are no active DSW or planned work orders.
Recommendation: None, facility is programmed for demolition.
Building Assessment Report
49800
HEAVY EQUIPMENT
SHOP
FACILITY ASSESSMENT REPORT
BUILDING 49800
HEAVY EQUIPMENT SHOP
2 MAY 2016
FACILITY ASSESSMENT CONTENTS
ASSESSMENT DETAIL REPORT
Contents include a Builder report detailing assessment results. Report shows data to the section level.
Summary data shows Building Condition Index (BCI), System Condition Index (SCI), Component Condition Index (CCI) and Section Condition Index (CSCI). For sections with protective coating assessment, included is a rating for Section Paint Condition Index (CCI). Inspection dates are included.
WORK ORDERS AND PROJECTS
Contents include a Builder report detailing recommended work orders and long term projects. Work Orders and Project data input indirectly from Maximo and ACES PM.
FIXED LADDER REPORT
Inventory and assessment of fixed ladders associated with the building.
CROSS-CONNECTION REPORT
Inspection of water system components required for prevention of backflow contamination.
ASBESTOS INSPECTION
Inventory of recorded asbestos materials in the building.
REAL PROPERTY INVENTORY
Depicts last real property inventory report with a reconciliation of “floor-to-book and book-to-floor” of accountable records. If an inventory was due during the period of condition assessment, the new task was completed with the report shown.
ASSESSMENT DETAIL REPORT
PROJECT INFORMATION
DBEH111638 Demolish Heavy Equipment Shop, FY18
FIXED LADDER REPORT
Not applicable.
CROSS-CONNECTION REPORT
Not applicable.
ASBESTOS INSPECTION
The facility does not contain friable asbestos containing material.
REAL PROPERTY INVENTORY
| 49800 CHSAsbestosReport |
| 49800 CHSAsbestosSamplingReport |
| Appendix 49800 FCA_CCAFS IOMS 2009 |
| Appendix building assessment summary 49800 |
| Appendix FACILITY ASSESSMENT REPORT 49800 |