Tech Exhibit 5e_AFPSL Measurement Capabilities.doc

DOC document 63 KB Posted

Attached to
AFPSL Recompete Federal contract opportunity
Solicitation number
FA2263-20-R-0002
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

This document contains a technical exhibit outlining measurement capabilities relevant to fiber optics and infrared technologies, along with a related federal contract opportunity notice. The technical exhibit provides specifications for non-connectorized and connectorized power sensitivity, spectrum analyzers, and sources in fiber optics, as well as radiometric temperature, spectral radiance, and emissivity capabilities for infrared measurement. The federal contract opportunity is a solicitation from the Department of the Air Force Materiel Command Lifecycle Management Center seeking proposals for the AFPSL Recompete program. It references a second draft solicitation and questions from an initial posting, with final proposals due on January 31, 2020 and anticipation of adding a bidder's library with relevant documents after the new year.

View the file

Other files for this federal contract opportunity

Other files attached to AFPSL Recompete, newest first.
File Type Posted
Solicitation Amendment FA226320R00020004 SF 30.pdf PDF
AFPSL Recompete Section L Rev 3.docx DOCX document
Solicitation Amendment FA226320R00020003 SF 30.pdf PDF
FA226320R0002 AFPSL_Questions.docx DOCX document
AFPSL Recompete Section L Rev 2.docx DOCX document
Section L Attachment 2 PPI Tool Instructions Rev 1.docx DOCX document
AFPSL Draft RFP Questions and Responses2.docx DOCX document
Attachment 5a_Facilities Lease Agreement.docx DOCX document
AFPSL Recompete Incentive Plan.docx DOCX document
AFPSL Recompete PWS.docx DOCX document
AFPSL Recompete Section M.docx DOCX document
Attachment 6_GFE Usage Fee.docx DOCX document
Attachment 3_Radioactive Material List.doc DOC document
Attachment 2a_Workload.xlsx XLSX spreadsheet
Attachment 5e_AFPSL Measurement Capabilities.docx DOCX document
AFPSL Recompete Section L.docx DOCX document
Attachment 2b_Turnaround Time Exceptions.xlsx XLSX spreadsheet
Section L Attachment 1 Solicitation_Cross_Reference_Matrix.docx DOCX document
Attachment 4_Data Requirements Cross Reference.docx DOCX document
Attachment 5b_GFE List.xlsx XLSX spreadsheet
DOL Wage Determination.pdf PDF
Solicitation - FA226320R0002.pdf PDF
DOL CBA Rev2.pdf PDF
Attachment 7_ Accreditation Areas.xlsx XLSX spreadsheet
Data Requirements.pdf PDF
Section L Attachment 2 PPI Tool Instructions.docx DOCX document
AFPSL_5_Year_Accredited_Cal Items Shipped - Bidder's Library.xlsx XLSX spreadsheet
21-2 - US AFPSL Calibration Procedure TOs - 8 March 2016 - Bidder's Library.pdf PDF
AFPSL Draft RFP Questions and Responses2.docx DOCX document
AFPSL Cal Software list - Bidder's Library.xlsx XLSX spreadsheet
Note64 report - Bidder's Library.xlsx XLSX spreadsheet
33K-1-100-1 - Bidder's Library.pdf PDF
AFPSL_5_Year_Commercial_Calibration_Data - Bidder's Library.xlsx XLSX spreadsheet
TO 00-20-14_20190131 - Bidder's Library.pdf PDF
AFPSL_5_Year_History_Listing - Bidder's Library.xlsx XLSX spreadsheet
AFPSL_Priority_Workload - Bidder's Library.xlsx XLSX spreadsheet
Draft Solicitation - FA226320R0002.pdf PDF
Section L Attachment 2 PPI Tool Instructions.docx DOCX document
AFPSL Recompete Section M 20191217.docx DOCX document
AFPSL Recompete Incentive Plan.docx DOCX document
DOL CBA Rev2.pdf PDF
Tech Exhibit 3_Radioactive Material List.doc DOC document
Tech Exhibit 6_GFE Usage Fee.doc DOC document
Tech Exhibit 1_SDS.xlsx XLSX spreadsheet
Tech Exhibit 5b_GFE List.xlsx XLSX spreadsheet
Tech Exhibit 4_Data Requirements Cross Reference.docx DOCX document
Tech Exhibit 7_ Accreditation Areas.xlsx XLSX spreadsheet
AFPSL Draft RFP Questions and Responses.docx DOCX document
Tech Exhibit 5a_Facilities Lease Agreement.docx DOCX document
Tech Exhibit 2b_Turnaround Time Exceptions.xlsx XLSX spreadsheet
Show all 50

AFPSL Recompete has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Technical Exhibit 5e

29 August 2018

AFPSL MEASUREMENT CAPABILITIES

Air Force Critical Information

FIBER OPTICS MEASUREMENT AREA

Parameter Range Uncertainty Reference Std.

Power Sensitivity Non-Connectorized 0 to -60 dBm:

800 - 900 nm ±0.25 dB (1%

1250 - 1350 nm

1500 - 1600 nm

Connectorized +3 to -60 dBm

800 - 900 nm ±2%

1250 - 1350 nm

1500 - 1600 nm

(1%

Spectrum Analyzers 365 nm to 1530 nm ±0.5 nm (0.05 nm

(Wavelength)

Sources (LEDs & LDs) Spectral Properties ±2 nm

0.5 nm

INFRARED MEASUREMENT AREA

Radiometric Temperature 200 - 1200 (C ±1.40 (C ±0.22 (C with Emissivity

(0.005 (0.00002 (Blackbodies)

Spectral Radiance <300 nm ±4% ±1.7% (Lamps) 300-2400 nm ±3% ±1.1% Spectral Irradiance <350 nm ±5% ±2.2% (Lamps) 350 – 1600 nm ±4% ±1.9%

>1600 nm ±8% ±6.5% Noncontact Thermometry 20 - 800( C ±5% of F.S.

850 - 2300( C (6( C (2.5( C

2300 - 2500( C (8( C (2.5( C

Spectral Transmission Wavelength (185 - 3200 nm) ±0.6 nm

Transmittance

(10% - 100%) ±2.5% of Value

(1.0% - 10%) ±5% of Value

(0.1 % - 1.0%) ±8% of Value

(less than 0.1 %) ± 15% of Value

Spectral Transmission Wavelength (2.5 - 25 (m) ±0.6 (m

Transmittance

(10% - 100%) ±2.5% of Value

(1.0% - 10%) ±5% of Value

(0.1% - 1.0%) ±8% of Value

(less than 0.1%) ±15% of Value

LASER MEASUREMENT AREA

Parameter Range Uncertainty Reference Std.

Peak Power (Irradiance)

1.06 (m, 1.0 - 100 mW/cm2 ±2.5 dB ±7.0%

1 (W/cm2 - 1.1 W/cm2 ±15.0% ±7.0%

Fluence (Energy/Pulse)

1.06 (m, 10 - 7000 fJ/cm2 ±10.0%

Average Power (Q-Switched)

1.06 (m, 1.0 mW - 3 W ±5.0% ±1.0%

CW Power 488 nm, 1.0 mW - 2.0 W ±5.0% ±1.0%

514.5 nm, 1.0 mW - 2.0 W

632.8 nm, 20 nW - 60 mW

1.06 (m, 1.0 mW - 2.0 W

10.6 (m, 200 mW - 150 W

±2.0%

10.6 (m, 50 W - 1500 W

±3.0%

CW Power (On-Site) 1 - 11 (m, 50 W - 200 kW ±5.0% ±3.0%

PHOTOMETRICS MEASUREMENT AREA

Luminous Intensity 25 - 2000 Candela ±2.0% (0.5%

Color Temperature 2000 - 3200( K ±20( K From Spectral Irradiance

Luminous Directional Intensity

0.43 - 0.7 fL/fC ±1.5% (0.7%

UV Irradiance 365 nm, 0 -3 mW/ cm2 ±7%% (5%

RADIAC MEASUREMENT AREA

Alpha Standards

0 - 13,000,000 CPM

±5.0% ±1.0% Gamma Standards 1 mR/hr - 10,000 R/hr ±5.0% ±1.0% Alpha Meters

0 - 13,000,000 CPM

±20.0% ±1.0%

Gamma Meters 1 mR/hr - 500 R/hr ±10.0% ±1.0%

Neutron Meters 1 - 15,000 mRem/hr ±15.0% ±5.0%

DC/LOW FREQUENCY MEASUREMENT AREA

Parameter Range Uncertainty Reference Std.

Range/Uncertainty

Capacitance 0.01pf - 1000 pf @ 1000 Hz ±0.001% to ±0.002% 1000 pf @ 1000 Hz/± 0.0004%

1 pf @ 1000 Hz (Coaxial) ±0.1% 1 pf @ 1000 Hz/± 0.052%

Resistance

0.001 ( to 1T( ±0.0002% to ±0.2% 10 k(/± 0.000015%

10 k( ±0.0001%(w/historical data) 10 k(/± 0.000015%

1 ( ±0.0006%(w/historical data) 1 (/± 0.00005%

DC Current

0.00001 A to 300 A

±0.004 to ±0.02%

0.00001 A to100 A/±0.0004% to

±0.002%

AC Current 10 mA to 30 mA (100 kHz) ±0.015% 10 mA to 30 mA/±0.01%

10 mA to 20 A (1 kHz, 1 0 kHz) ±0.01% to ±0.03% 10 mA to 20 A/±0.005% to ±0.015%

Inductance 100 mH @ 1 kHz ±0.03% 100 mH @ 1 kHz/±0.02%

Thermal Voltage Converters 0.45V to 100 V (1 MHz to 100 MHz) ±0.06% to ±1.1% Same/±0.02% to ±0.5%

Thermal Transfer 0.0022V to 1000 V (10 Hz to 30 MHz) ±0.0022% to ±0.62% Same/±0.001% to ±0.5%

Standard Multi-range

AC Flatness Input Resistance: 50 ( ±1.0% Measured w/DMM

(Peak-to-Peak Detector) Sensitivity: 1% P-P change to ±1 mV Measured w/DMM produce a 10 mV DC change in output

Frequency Response:

±0.2% to ±1.6% 50 Hz to 500 MHz/±0.08% to ±1.2%

(50 kHz reference)

0.1 MHz to 500 MHz

Helmholtz Coils 0 to 1000 Gauss ±0.1 % to ±2.5% Absolute Standard

(magnetic field strength)

Reference Magnets 0 to 20 kGauss ±0.6% to ±2.5% Absolute Standard

DC Voltage (low) Standard Cells: 1.018 V

1.018 V/±0.00005%

Zener Reference: 10 V

10 V/±0.00005%

DC Voltage (high) 5 kV to 100 kV ±0.025%

5 kV to 75 kV/±0.01%

AC Voltage (high) 15 kV to 100 kV ±1.0%

5 kV to 75 kV/±0.03%

DC Voltage Ratio 0 to 1.0 ±0.05 ppm (terminal linearity) N/A

10: 1 ratio ±0.2 ppm

100: 1 ratio ±0.5 ppm N/A

AC Voltage Ratio Transfer Ratio Corrections

0 to 1.0 (50 Hz to 10 kHz)

(50 Hz to 1 kHz) ±0.0001% (50 Hz to 1 kHz)/±0.00005%

(1 kHz to 10 kHz) ±0.0001% x (Freq(kHz)2 ) (1 kHz to 10 kHz)/±0.00005% x (Freq(kHz)2)

Risetime 25 Picoseconds ±7 Picoseconds 25 Picoseconds/±5 Picoseconds

Precise Time and Time: Universal Time Coordinate ±10 nanoseconds of UTC

USNO

Frequency steered by USNO

Frequency: 100 kHz to 10 MHz ±1.1 X 10-13 fractional

USNO

frequency offset

Phase Angle 1 Hz to 100 kHz ±(5+0.1 R) millidegrees to ±(48+R) millidegrees where R is the ratio of the larger to the smaller output voltage (i.e. reference voltage, variable phase voltage)

RF/MICROWAVE MEASUREMENT AREA

Parameter Range Uncertainty Reference Coaxial Power

0.1 to 10 MHz

1.0 to 1.25% 0.5%

0.01 to 18 GHz

1.5 to 2.6%

0.8 to 1.7%

18 to 26.5 GHz 4.4% 2.4%

26.5 to 40 GHz 4.0% 2.1%

Waveguide Power

8.2 to 40 GHz

1.75 to 3.6%

1.5 to 2.4%

33 to 50 GHz

2.6 to 4.5%

1.65 to 3.54%

High Power

1 MHz to 1.3 GHz

3.0 to 3.5%

2.4 to 2.9%

1 to 1000 Watts Attenuation

1.25 MHz (Var)

0.01 dB of charted value 0.002/6 dB*1

30 MHz

0.01 dB of charted value 0.005/10 dB*1

2.5 MHz to 26.5 GHz (0 to 100 dB)

0.015+0.005/10 dB step+1digit*1 0.003+0.003/10 dB*1

2.5 MHz to 26.5 GHz (100 to 120 dB)

0.015+0.05/10 dB step+1digit* 0.003+0.003/10 dB*1

2.5 MHz to 26.5 GHz (120 to 127 dB)

0.05+0.02/10 dB step+1digit 0.003+0.003/10 dB*1

+0.18 dB noise*1

26.5 to 40 GHz (0 to 50 dB) 0.045*2

0.01 dB of charted value

Coaxial Reflection BNC: 100 kHz to 100 MHz

0.01 to 0.03*2 <0.00025 @ 30 MHz

Coefficient 14 mm: 100 kHz to 8.5 GHz

0.007 to 0.04*2

0.0016 to 0.0020*2

N: 100 kHz to 18 GHz

0.007 to 0.04*2

0.0011 to 0.0020*2

7 mm: 100 kHz to 18 GHz

0.005 to 0.025*2

0.0016 to 0.0018*2

3.5 mm: 100 kHz to 26.5 GHz

0.01 to 0.07*2

0.0015 to 0.0030*2

2.92 mm: 100 kHz to 40 GHz (SWR<2)

0.025 to 0.15*2

0.0009 to 0.0012*1

2.4 mm: 100 kHz to 40 GHz (SWR<2)

0.015 to 0.09*2

0.0009 to 0.0012*1 Waveguide Reflection

2.6 to 40 GHz (SWR <2)

0.015 to 0.06*2 <1.01413*2 Coefficient

40 GHz to 50 GHz (SWR <2) <1.1 <1.01413*2 VHF Omnidirectional 0 to 359.99 degrees

0.09 degrees 0.01( @ 0( Ranging

0.02( @ all other bearing angles

AM (Instrument Landing 90, 150 Hz (0.1 to 0.2)% 0.05%

System)

(Based on a modulation depth of 0 to 50%)

AM Modulation 20 Hz to 100 kHz 1 to 3%*2 0.3% of reading + 1 digit*2

(1 50 kHz to 1300 MHz carrier frequency)

FM Modulation 20 Hz to 200 kHz 1 to 5%*2 0.75% rdg*2

(250 kHz to 1300 MHz

Phase Modulation 200 Hz to 20 kHz 3*3 0.1% (Total Harmonic

(1 50 kHz to 1300 MHz

Distortion)

Power Density 2450 MHz 2 dB

0.5 dB

Coaxial Thermal Noise

0.01 to 8 GHz

0.23 dB*4

0.23 dB*4

8 to 26 GHz

0.32 dB*4

0.32 dB*4

26.5 GHz

0.35 dB

0.35 dB

Waveguide Thermal Noise

8.2 GHz to 12.4 GHz

0.2 dB

0.05 dB*4

12.4 to 18 GHz

0.25 dB

0.09 dB*4 Phase Noise 5 MHz to 1.6 GHz 2 dB (0.01Hz to 1MHz offset)

0.3 to 2.0 dB (Spec An linearity)

1.6 GHz to 18 GHz

4 dB (1MHz to 40MHz offset)

0.3 to 2.0 dB (Spec An linearity)

Phase

0.045 to 26.5 GHz

0.2 to 180 degrees

0.2 to 180 degrees

(Reflection/Transmission)

(varies with frequency, (varies with frequency, connector type, and connector type, and reflection/transmission reflection/transmission coefficient) coefficient)

*1 Plus mismatch error

*2 Varies with frequency and reflection coefficient

*3 Varies with carrier frequency and modulation rate

*4 Varies with frequency

FORCE MEASUREMENT AREA

Parameter Range Uncertainty Reference Std.

Dead Weight Machines 0- 100000 lbf ±0.003% rdg

GAS FLOW MEASUREMENT AREA

Nozzle Stand 0 - 440 scfm ±0.5% rdg NIST Cal'd Nozzles ±0.30% rdg

Laminar Stds

0.02 - 1 000 lpm ±1% rdg NIST Traceable Element ±0.25% rdg Volumetric Displacement

0.02 - 50 lpm ±1% rdg Bell Provers ±0.30% rdg Air Velocity 30 - 9000 fpm ±4% rdg Wind Tunnel ±2.0% rdg

MASS MEASUREMENT AREA

Mass (minimum) 1 milligram ±5 micrograms

Mass (maximum) 50 Kilograms ±9.85 milligrams

PRESSURE MEASUREMENT AREA

Pneu. Pressure Piston Gauge 0.2-700 psi ±0.006% rdg

Hydraulic Pressure Piston Gauge 50-40000 psi ±0.01% rdg

Hydraulic Pressure Piston Gauge 6-15000 psi ±0.01% rdg

Oxygen Pressure Piston Gauge 500-15000 psi ±0.01 % rdg

SOUND MEASUREMENT AREA

Microphones (re 1 V/Pa) 50 - 10 kHz ±0.15 dB NIST Cal'd Microphone +0.09 dB

Sound Dosimeters 2 Hz - 10 kHz ±0.30 dB NIST Cal'd Microphone +0.09 dB

Sound Calibrators 1 kHz ±0.50 dB NIST Cal'd Microphone +0.09 dB Sound Level Meters 2 Hz - 10 kHz ±0.50 dB NIST Cal'd Microphone +0.09 dB

Piston Phones 250 Hz ±0.30 dB NIST Cal'd Pistonphone +0.10 dB

TEMPERATURE MEASUREMENT AREA

Thermocouples 0 to 11000 C ±10 C NIST Cal'd Thermocouple ±0.10 C Platinum Resistance Therm.

-190 to 6610 C ±0.010 C NIST Cal'd SPRT <±0.000 C Optical Pyrometer 900 to 22000 C ±1% of Scale NIST Cal'd Pyrometer ±1.0% Scale

VACUUM MEASUREMENT AREA

Low Vacuum(Capacitance Gage) 10-3 Torr to 1 Torr ±0.001 to ±0.007 Torr NIST Cal'd Gage ±0.3% rdg Low Vacuum 1 Torr to 100 Torr ±0.00625 to ±0.65 Torr NIST Cal'd Gage ±0.3% rdg High Vacuum (Ion Gauge) 10-8 Torr to 10-4Torr ±20% to ±40% rdg NIST Cal'd Gage ±6 to 25% rdg High Vacuum(Spin Rotor Gauge) 10-6 Torr to 10-2 Torr ±5% rdg NIST Cal'd Gage ±1.0% rdg

HUMIDITY MEASUREMENT AREA

Dewpoint -70 to 200 C ±1.50 C NIST Cal'd Chilled Mirror ±0.30 C Relative Humidity 5 to 95% ±1.5% rdg Dual Pressure/Temp System ±1.0 %

VIBRATION MEASUREMENT AREA

Accelerometers 5 Hz to 10 kHz ±3.0% of output NIST Cal'd Accelerometer ±1 to 2% of output

DIMENSIONAL MEASUREMENT AREA

Parameter Range Uncertainty Reference Std.

Gage Blocks 0 to 0.090 inch ±3 (in ±2 (in

±6 (in

0.100 to 4 in

5 to 12 in ±3 (in

5 to 20 in ±1 (in/in ±1 (in/in

Horizontal Length 0 to 12 in ±20 (in

13 to 36 in ±2 (in/in ±1 (in/in

Circularity

0.0625 to 4 in ±4 (in

4 to 12 in ±4 (in ±1 (in/in

Cylindricity 1 to 4 in ±30 (in

4 to 11 in ±30 (in ±1 (in/in

Flatness 4 to 12 in ±0.5 (in

1 to 12 in ±1.5 (in above 12 to 16 in ±4.0 (in ±0.5 (in

Surface Finish 2 to 100 (in ±2% of Nominal ±0.51 (in

(Depth of SCRATCH)

8 to 250 (in ±2% of Nominal ±0.59(in

(Ra)

Internal/External Diameters

0.125 to 4.0 in

4 to 7 in ±8 (in ±1 (in/in

Internal/External Thread 0 to 4 in ±40 (in ±2 (in

Geometry

Thread Wires 80 to 4 pitch diameter ±20 (in ±2 (in

Steel/Glass Scales 0 to 4 in ±50 - 100 (in

4 to 18 in ±50 - 100 (in ±1 (in/in

OPTICS MEASUREMENT AREA

Angle - Polygon Face 0 - 360 degrees ±0.25 arc sec Absolute Calibration

Angle - Angle Blocks 0 - 45 degrees ±0.4 arc sec

0.25 arc sec

Angle - Indexing Table 0 - 360 degrees ±0.5 arc sec Absolute Calibration

Pentaprism 90 degrees ±0.25 arc sec Absolute Calibration

Angle - Theodolite (First Order)

Horizontal Circle 0 - 360 degrees ±0.4 arc sec Absolute Calibration

Collimation

±2 arc sec 1 arc sec

Vertical Leveling

±1 arc sec

Angle - Tilt Angle Generator 0 - 100 arc sec ±0.2% of nominal

0.1 arc sec

100 - 1000 arc sec ±0.3% of nominal

0.2 arc sec

Angle - Autocollimator 10 arc sec ±0.01 arc sec* Modeling technique

40 arc sec ±0.03 arc sec*

150 arc sec ±0.05 arc sec*

300 arc sec ±0.5 arc sec

0.2 arc sec

1800 arc sec ±2 arc sec

0.5 arc sec

Mirror Flatness 1 -10 inch diameter ±1.0 (in

0.5 (in Mirror Flatness (Rectangular) up to 18 in ±1.0 (in

0.5 (in Laser Frequency Stability

546.1 - 632.8 nm ±5 x 10-10

(Power 3mw or less)

Length - Electronic Distance 0 to 100 m ±5 mm Absolute Calibration

Measuring above 100 - 1000 m ±7 mm Est. based on Comm data

*Based on AAMACS operation; without AAMACS, 0.25 arc sec