About this file

This is an Experience Data Sheet template used for proposal submission in response to solicitation N4008426R1026, an Indefinite Delivery/Indefinite Quantity (IDIQ) contract for Custodial, Pest Control, and Grounds Maintenance Services at U.S. Marine Corps Air Station (MCAS) Iwakuni, Japan. The form is designed to document the offeror's relevant project experience and must not exceed two single-sided pages when completed.

The Experience Data Sheet requires offerors to provide detailed information about up to four relevant projects, including firm identification data (UEI number, CAGE code, point of contact), work performance role (prime contractor, subcontractor, or joint venture), contract execution dates, and total contract values. Offerors must identify the specific contract type (Firm-Fixed Price, Cost/Time and Material) and contract vehicle (Stand-Alone or IDIQ Delivery/Task Order). The form includes checkboxes for four specific specification items relevant to this solicitation: Operation and Maintenance for Granular Activated Carbon (GAC) filtering systems, Operation and Maintenance for Wastewater Treatment Plants, Maintenance for Incinerator Plants, and Cleaning/Disinfection/Maintenance for Potable Water Tanks. Offerors must provide detailed project descriptions demonstrating relevancy to RFP requirements, including project size, scope, and complexity, as well as descriptions of work self-performed by the firm. This template serves as a standardized mechanism for evaluating contractor experience and past performance capabilities.

View the file

Other files for this federal contract opportunity

Other files attached to Indefinite Delivery/Indefinite Quantity (IDIQ) Custodial, Pest Control, and Grounds Maintenance Service Contract at U. S. Marine Corps Air Station (MCAS) Iwakuni, Japan, newest first.
File Type Posted
N4008426R1026 AMD 0001.pdf PDF
Encl 4_Experience Data Sheet AMD 1.pdf PDF
Request for Information Questions and Responses.pdf PDF
Solicitation - N4008426R1026.pdf PDF
Encl 3_Safety.docx DOCX document
Encl 7_APPENDIX A-INDIVIDUAL ACKNOWLEDGEMENT AND MEMORANDUM OF UNDERSTANDING FOR COMPLIANCE WITH MCASO.pdf PDF
Encl 11_MCASO 5500.2W MCAS Iwakuni Access Control.pdf PDF
Encl 6_RFI Form.xlsx XLSX spreadsheet
Encl 8_APPENDIX A-JN-INDIVIDUAL ACKNOWLEDGEMENT AND MEMORANDUM OF UNDERSTANDING FOR COMPLIANCE WITH MCASO.pdf PDF
Encl 10_MCASO 5500.2W Appendix.pdf PDF
Encl 2_ELINs Schedule.xlsx XLSX spreadsheet
Encl 1_PWS_CPG_Iwakuni_w_combined.pdf PDF
Encl 5_PPQ_with Japanese Translation.docx DOCX document
Encl 9_MCASO 3070.2B.pdf PDF
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CUI [when filled in] Source Selection Information – See FAR 2.101 & 3.104 [when filled] Attachment 2 – N40084-26-R-1026

EXPERIENCE DATA SHEET

Individual blocks on this form may be expanded; however, total length should not exceed 1 double-sided (2 single-sided) pages.

Project No. (check one) : |_| PROJECT #1 |_| PROJECT #2 |_| PROJECT #3 |_| PROJECT #4

1. Experience for: |_| Offeror |_| Joint-Venture |_| Other (Explain)

Firm Name: ________________________________________________________________________ Address: ___________________________________________________________________________ UEI Number: ____________________________________ CAGE: __________________________ Point of Contact/Position: ____________________________________________________________ Contact Phone Number/Email: ________________________________________________________

2. Work Performed as: |_| Prime Contractor |_| Sub Contractor |_| Joint Venture |_| Other (Explain) Number of completed years _______ Total Contract Value: ____________________________ If subcontractor, who was prime (Name & Phone/Email): ___________________________________________________

3. Contract Number: _____________________________ Delivery/Task Order Number: _____________________ Title: __________________________________________________________________________________________ Location: _______________________________________________________________________________________

4. Award Date (mm/dd/yy): _____________________ Completion Date (mm/dd/yy): ____________________

5. Type of Relevant Annex(es) for the work indicated in Factor 2 and Price of Work Performed for each Annex/Sub-Annex:

|_| Spec Item 1604000 3.2.2 Operation, and Maintenance for Granular Activated Carbon (GAC) filtering system (Price of Work: ) |_| Spec Item 1604000 3.2.1 Operation, and Maintenance for Waste Water Treatment Plant (Price of Work: ) |_| Spec Item 1502000 3.2.1 Maintenance for Incinerator Plant (Price of Work: ) |_| Spec Item 1502000 3.2.3.1 Cleaning, disinfection and maintenance for Potable Water Tanks (Price of Work: )

6. Type of Contract/Task Order: (Check ALL that apply)

|_| Firm-Fixed Price |_| Cost/Time and Material |_| Other (explain):

7. Project:

Award Amount of Work Performed: Final Price of Work Performed:

Type of Contract/Task Order: (Check ALL that apply)

|_| Stand-Alone |_| Delivery/Task Order (IDIQ) |_| Other (explain):

9. Provide a detailed description of the project and the relevancy to the project requirements of this RFP. Include how this project meets the definition of a relevant project (size, scope, complexity).

10. Provide a detailed description of what work your firm self-performed on this project:

11. Other Information:

Revised April 2011

CUI [when filled in] Source Selection Information – See FAR 2.101 & 3.104 [when filled]

File details come from the government source that posted it. Updated .