This document contains the results of an asbestos inspection and lead paint testing report for the ACAD - Rehabilitate Schoodic Water and Wastewater Systems project located at the Schoodic Institute in Acadia National Park, Winter Harbor, Maine. Samples were collected from the standalone pumphouse building and bomb shelter and pump room areas within Eliot Hall basement and analyzed for asbestos and lead content. Asbestos was not detected in any of the samples analyzed. Lead was detected in paint samples from metal pipes, CMU walls, and a metal door at levels between 0.94% and 3.6% by weight. The report provides findings and regulatory guidance on asbestos and lead for the referenced project locations.
Additionally, the solicitation is for the ACAD 312255 - Rehabilitate Schoodic Water System project at Acadia National Park in Winter Harbor, Maine. The solicitation was issued by the National Park Service National Office within the Department of the Interior. No other details are provided about requirements, pricing, response dates, or other terms.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Inspection &
Lead Paint Testing Report Acadia National Park
Schoodic Institute
Winter Harbor, Maine 04693
Project: ACAD - Rehabilitate Schoodic
Water and Wastewater Systems April 11, 2022
Terracon Project J1215067
Prepared for:
VHB, Inc.
Watertown, Massachusetts
Prepared by:
Terracon Consultants, Inc.
Manchester, New Hampshire
Terracon Consultants, Inc. 77 Sundial Ave Suite #401w Manchester, NH 03103
P [603] 647 9700 terracon.com
April 11, 2022
VHB, Inc.
101 Walnut Street Watertown, Massachusetts 02471
Attn: Mr. Timothy Bryant, PE
Director of Structural Engineering
P: (773) 336-7922
E: Brosenblum@GWProperties.com
Re: Asbestos Inspection & Lead Paint Testing Report
Project: ACAD - Rehabilitate Schoodic Water and Wastewater Systems
Acadia National Park
Schoodic Institute
Winter Harbor, Maine 04693
Terracon Project No. J1215067
Dear Mr. Bryant:
Terracon Consultants, Inc. (Terracon) is pleased to submit the attached report for the above-referenced project to VHB, Inc. (VHB). The purpose of this report is to present the results of an asbestos inspection and lead paint testing which were performed at the project site on February 28, 2022. This scope of services was conducted in accordance with VHB’s Task Order Authorization, dated September 28, 2021.
Lead-containing paint (LCP) was identified as a result sampling and laboratory analysis. Asbestos-containing materials (ACM) were not identified as a result of sampling and laboratory analysis.
Please refer to the attached report for further detail.
We trust this report meets your needs at this time. If you have any questions regarding this report, please feel free to contact us.
Sincerely, Terracon Consultants, Inc.
Adam Frey Joseph Tussey, CHMM
Staff Scientist Authorized Project Reviewer http://terranet.terracon.com/dept/marketing/PublishingImages/ServicesBar13Update.jpg
Responsive ■ Resourceful ■ Reliable
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Project Objective
2.0 PROJECT/STRUCTURE DESCRIPTION
3.0 FIELD ACTIVITIES
3.1 Asbestos-Containing Materials Inspection
3.1.1 Visual Assessment
3.1.2 Physical Assessment
3.1.3 Sample Collection
3.1.4 Sample Analysis
3.2 Lead-Containing Paint Testing
3.2.1 Lead Paint Sample Collection and Analysis
4.0 REGULATORY OVERVIEW
4.1 Asbestos-Containing Materials
4.2 Lead Paint
5.0 FINDINGS AND RECOMMENDATIONS
5.1 Asbestos-Containing Materials
5.2 Lead-Containing Paint
6.0 LIMITATIONS/GENERAL COMMENTS
LIST OF APPENDICES
APPENDIX A ASBESTOS INSPECTION SAMPLE LOCATION SUMMARY
APPENDIX B SAMPLE LOCATION DRAWINGS
APPENDIX C PHOTOGRAPHIC DOCUMENTATION
APPENDIX D LABORATORY ANALYTICAL DATA
APPENDIX E INSPECTOR’S LICENSE
Responsive ■ Resourceful ■ Reliable 1
ASBESTOS INSPECTION &
LEAD PAINT TESTING REPORT
PROJECT: ACAD - REHABILITATE SCHOODIC
WATER AND WASTEWATER SYSTEMS
Acadia National Park
Schoodic Institute
Winter Harbor, Maine 04693 Terracon Project No. J1215067
April 11, 2022
1.0 INTRODUCTION
Terracon Consultants, Inc. (Terracon) conducted an asbestos inspection and lead paint testing for the ACAD: Rehabilitate Schoodic Water and Wastewater Systems project which is located at the Schoodic Institute in Acadia National Park, Winter Harbor, Maine. The purpose of this scope of services was to sample/test, identify, and locate suspect asbestos-containing materials (ACM, and paints containing lead (lead-containing paint {LCP}) pertaining to the stand alone pumphouse building and the bomb shelter and pump room in the basement of Eliot Hall.
The scope of services was conducted at the site on February 28, 2022 by State of Maine
Department of Environmental Protection (ME DEP)-licensed asbestos inspector, Mr. Adam Frey, in accordance with the Client’s Task Order authorization, dated September 28, 2021.
Homogenous areas of suspect asbestos-containing materials (ACM) were visually identified and documented. Suspect ACM samples were collected in accordance with the sampling protocols outlined in United States Environmental Protection Agency (USEPA) 40 Code of Federal
Regulations (CFR) Part 763, Subpart E, known as the Asbestos Hazard Emergency Response
Act (AHERA). Samples were delivered to an accredited laboratory for analysis by polarized light microscopy (PLM) and the additional transmission electronic microscopy (TEM) with gravimetric reduction analytical method when applicable for non-friable organically bound (NOB) materials.
In conjunction with the asbestos inspection, Terracon conducted sampling of representative acessible suspect lead-containing paints to identify and assess the condition of accessible painted buiding components that are suspected of containing lead. The sampling was of a limited nature specific to project and accessible areas. Paint samples were analyzed for lead content via EPA
Method SW-846-7000B, Flame Atomic Absorption Spectrophotometry.
1.1 Project Objective
We understand this scope of services was requested to identify, locate and sample suspect ACM for laboratory analysis, sample paints for lead-content laboratory analysis, and provide information regarding materials identified by analysis to contain asbestos and components with
Asbestos Inspection & Lead Paint Testing Report
Acadia National Park - Schoodic Institute ■ Winter Harbor, ME
April 11, 2022 ■ Terracon Project No. J1215067
Responsive ■ Resourceful ■ Reliable 2 lead paint, if any, for the above-referenced pumphouse and basement area. USEPA regulation 40
CFR 61, Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP) and state regulations prohibit the release of asbestos fibers to the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated ACM be identified, classified and quantified prior to planned disturbances or demolition activities. Regarding paints with lead, the Occupational Safety and Health Administration (OSHA) regulation 29 CFR 1926.62 (Lead in
Construction) requires contractor compliance when disturbing lead.
2.0 PROJECT/STRUCTURE DESCRIPTION
As noted above in Section 1.0, the areas included in our scope of services included the accessible interior and exterior areas of the standalone pumphouse building and the Client-specified bomb shelter and pump room areas within the interior of the Eliot Hall basement.
Eliot Hall is located in Winter Harbor, Maine, and currently operates as an education center on the Schoodic Institute campus. The building is a brick structure with multiple classrooms bathrooms, offices, and a basement. The age of the structure was unknown to Terracon. As previously noted, our scope was limited to the interior of the bomb shelter and pump room in the basement and didn’t include any other areas of Eliot Hall.
The pumphouse building is located on a trail from Mountain Road, approximately three (3) miles from Eliot Hall. The structure contains a well and is enclosed in a wood-framed structure of approximately 65 square feet.
3.0 FIELD ACTIVITIES
3.1 Asbestos-Containing Materials Inspection
The asbestos inspection was conducted by Mr. Adam Frey, a MEDEP-licensed asbestos inspector
(license number AI-0784). A copy of his state asbestos inspector license is attached as Appendix
E. The inspection was conducted in accordance with the sample collection protocols established in USEPA regulation 40 CFR Part 763 (AHERA), Subpart E, Section 763.86 - Sampling. A summary of inspection activities is provided below.
3.1.1 Visual Assessment
The inspection activities were initiated with visual observation of subject project areas to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of application. The assessment was conducted in physically accessible areas of the subject areas.
Although reasonable effort was made to assess accessible suspect materials, additional suspect
Responsive ■ Resourceful ■ Reliable 3 but non-sampled materials could be located within walls, ceilings, pipe chases or in other concealed areas. Building materials identified as glass, fiberglass, wood, masonry, metal or rubber were not considered suspect ACM.
3.1.2 Physical Assessment
A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material that can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
3.1.3 Sample Collection
Based on results of the visual and physical observation, bulk samples of suspect ACM were collected in accordance with EPA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were collected using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content.
Terracon did not perform sampling requiring demolition or destructive activities such as knocking holes in walls, dismantling of equipment or removal of protective coverings. Electrical/mechanical equipment was not dismantled for interior inspections and materials such as wiring were not sampled due to safety issues.
Terracon collected a total of 30 bulk samples from 10 homogeneous areas of suspect ACM. A summary of suspect ACM samples collected during the inspection is included as Appendix A.
3.1.4 Sample Analysis
Bulk samples were submitted under chain of custody to EMSL Analytical, Inc. (EMSL) of South
Portland, Maine for analysis by polarized light microscopy (PLM) and the additional transmission electronic microscopy (TEM) with gravimetric reduction analytical method when applicable for non-friable organically bound (NOB) materials.
EMSL is a Maine Department of Environmental Protection (MEDEP) Environmental Laboratory
Accreditation Program (ELAP)-accredited laboratory for asbestos bulk sample analysis
(accreditation number 100194). EMSL is also accredited under the National Voluntary Laboratory
Responsive ■ Resourceful ■ Reliable 4
Accreditation Program (NVLAP; accreditation number 101048-0) for asbestos bulk sample analysis.
A summary of sample results is included with the sample summary in Appendix A. Sample location drawings are included in Appendix B. The laboratory analytical report is included in
Appendix D.
3.2 Lead-Containing Paint Testing
In conjunction with the asbestos inspection, Terracon conducted lead paint testing limited to representative components in representative projects areas in an effort to identify paints containing lead. This testing scope was not intended to meet the requirements of the HUD
Guidelines for the Evaluation and Control of Lead-Based Paint Hazards which is applicable for
HUD-funded residential housing.
3.2.1 Lead Paint Sample Collection and Analysis
Sample collection was performed using a clean straight-edge razor to remove paint from designated surfaces at random locations from dominant-type paint coatings. Collected paint samples were placed in new sealable containers and labeled with unique sample numbers using an indelible marker.
The paint chip samples were submitted for lead-content analysis to EMSL of Cinnaminson, New
Jersey. EMSL is accredited by the AIHA® Laboratory Accreditation Programs, LLC under the
Environmental Lead Laboratory Accreditation Program (ELLAP; accreditation number 100194).
Terracon collected from a total of six (6) paint samples (a summary with a description of the collected paint samples and analytical results is provided in Section 5.2, below). Samples were analyzed for lead content via EPA Method SW-846-7000B Flame Atomic Absorption
Spectrophotometry. The laboratory analytical report is included in Appendix C.
4.0 REGULATORY OVERVIEW
4.1 Asbestos-Containing Materials
The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity.
Friable ACM is a material containing more than 1% asbestos that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure. All friable ACM is considered regulated asbestos containing material (RACM).
Responsive ■ Resourceful ■ Reliable 5
The NESHAP regulation classifies ACM as RACM, Category I non-friable ACM or Category II non-friable ACM. RACM includes all friable ACM, along with Category I and Category II non-friable ACMs that have become friable or will be or have been subjected to sanding, grinding, cutting or abrading; or that have a high probability of becoming or have become crumbled, pulverized or reduced to powder in the course of renovation or demolition activity. Category I non-friable ACMs are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics and asphalt roofing products that contain more than 1% asbestos.
Category II non-friable ACMs are all other non-friable materials other than Category I non-friable
ACMs that contain more than 1% asbestos.
The Maine Department of Environmental Protection (DEP) enforces state asbestos regulations. Prior to demolition or renovation of a building, the owner must ensure that the work will not disturb more than three (3) square feet or three (3) linear feet of
ACM. Owners of buildings, other than residential buildings with less than 5 units, must have a DEP-licensed Asbestos Consultant inspect the building (or area) for asbestos. If
ACM is identified in a building that will be demolished, or any building materials are assumed to be ACM, these materials must be removed by a DEP-licensed Asbestos
Abatement Contractor before the demolition. Similarly, if any ACM is identified or assumed in areas of a building that will undergo renovation, the ACM must be removed by a DEP-licensed Asbestos Abatement Contractor before the renovation occurs. Intact asbestos-containing flooring and roofing may be left in place during demolition of a building if the demolition is performed by a DEP-licensed Asbestos Abatement Contractor using large equipment in accordance with the Maine “Asbestos Management
Regulations”. State regulations require that building owners notify the DEP at least five
(5) working days prior to demolition of a building (other than single-family residences). This notification is required even if no asbestos is identified in the building. Forms are available from DEP and local code enforcement offices.
4.2 Lead Paint
Lead is regulated by the USEPA, Maine DEP, and OSHA. The US HUD also has guidelines for the inspection, assessment, and abatement for defined lead-based paint (LBP) in residential settings under HUD funding. The USEPA and Maine DEP regulate lead use, removal, and disposal, and OSHA regulates lead exposure to workers. The USEPA and US HUD define LBP as paint, varnish, stain, or other applied coating that contains lead equal to or greater than 1.0 milligram per square centimeter (mg/cm2) as determined by laboratory analysis for bulk samples.
For the purpose of the OSHA lead standard, lead includes metallic lead, all inorganic lead compounds, and organic lead soaps. Lead containing paint (LCP), is paint with any detectable
Responsive ■ Resourceful ■ Reliable 6 levels of lead (levels above the analytical method’s reporting limit). A synopsis of the OSHA regulation (29 CFR 1926.62) and the applicability are as follows:
The OSHA Lead in Construction standard (29 CFR 1926.62) applies to all construction work where an employee may be occupationally exposed to lead (regardless of the lead concentration).
All work related to construction, alteration, or repair (including painting and decorating) is included.
The lead standard applies to any detectable concentration of lead in paint, as even small concentrations of lead can result in unacceptable employee exposures depending upon on the method of removal and other workplace conditions. Under this standard, construction includes, but is not limited to, the following:
◼ Demolition or salvage of structures where lead or materials containing lead are present.
◼ Removal or encapsulation of materials containing lead.
◼ New construction, alteration, repair, or renovation of structures, substrates, or portions containing lead, or materials containing lead.
◼ Installation of products containing lead.
◼ Lead contamination/emergency clean-up.
◼ Transportation, disposal, storage, or containment of lead or materials containing lead on the site or location at which construction activities are performed.
◼ Maintenance operations associated with construction activities described above.
5.0 FINDINGS AND RECOMMENDATIONS
5.1 Asbestos-Containing Materials
Asbestos was not identified in the samples collected and analyzed with respect the scope of this project-specific inspection. Please note that if a structure will be demolished, even if no ACM was identified as result of the inspection, state regulations require a five (5) working day notice to the
Maine DEP prior to demolition. For more information and notifications, please visit Maine’s DEP asbestos webpage at https://www.maine.gov/dep/waste/asbestos/index.html.
A sample and results summary table is included in Appendix A. Sample location drawings are included in Appendix B. The laboratory analytical report is included in Appendix D.
If additional but unsampled suspect materials (not listed in Appendix A) are discovered during the course of demolition or renovation activates, those materials should be assumed as asbestos-containing until sampled by an accredited inspector and laboratory analysis refutes the positive assumption.
https://www.maine.gov/dep/waste/asbestos/index.html
Responsive ■ Resourceful ■ Reliable 7
5.2 Lead-Containing Paint
A summary of the paint chip analysis results is presented in the following table. Data in bold indicates paints containing lead. A copy of the laboratory report for the paint chip samples is attached in Appendix B. Sample locations are shown on the diagram included in Appendix E.
Summary of Paint Samples and Analytical Results
Sample ID Color Substrate Component Sample Location Analytical
Result (% wt.)
PC-1 Blue Metal Pump
Coolers
Eliot Hall Basement, Pump Room
0.94 %
PC-2 Black/Red Metal Pipes Eliot Hall Basement, Pump Room
3.6 %
PC-3
Light
Yellow CMU Walls
Eliot Hall Basement, Outside Pump
Room
2.2 %
PC-4 White CMU Walls Eliot Hall Basement, Bomb Shelter
0.14 %
PC-5 Gray Metal Door Well House, Door <0.034 %
PC-6 Black Wood Wall Well House, Behind
Electric Panel <0.0080%
< = lead not detected above the analytical method’s reporting limit.
OSHA construction rules do not specify acceptable levels of lead within paints or other surface coatings for the purposes of occupational exposures. Construction work involving lead-containing paint must be completed in accordance with OSHA regulations, not limited to the lead standard, 29 CFR 1926.62 (Lead in Construction). Contractors completing work in areas found to contain lead, or where it is reasonable to assume lead may be present, should be notified of the presence
(and potential presence) of lead and proper work protocols should be used in accordance with 29
CFR 1926.62. Additionally, contractors must comply with applicable Owner project specifications when disturbing any paints confirmed or assumed (untested; not listed in the table above) to contain lead.
The lead paint testing was limited to dominant type painted surfaces described herein, and the scope of work outlined in our proposal. It should be understood that this limited lead paint sampling is not considered to be comprehensive in nature, and the results are not intended to be used to determine lead hazards, develop abatement plans, or prepare detailed cost estimates for abatement. Any untested paints should be assumed as lead-containing.
Responsive ■ Resourceful ■ Reliable 8
6.0 LIMITATIONS/GENERAL COMMENTS
In addition to limitations indicated in other sections of this report, if any, Terracon did not perform sampling which required demolition or destructive activities such as knocking large holes in walls, dismantling of equipment or removal of protective coverings. Electrical equipment, electrical lines, and active equipment such as inside of boilers, HVAC units, and elevator shafts were not included in this scope of services as such item present a safety hazard to the inspectors. Reasonable efforts to access suspect materials within known areas of restricted access (e.g., crawl spaces) were made; however, confined spaces or areas which may pose a health or safety risk to Terracon personnel were not sampled. Sampling did not include suspect materials which could not be safely reached with available ladders/man-lifts.
The scope of services was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our inspection/testing pertaining to the authorized scope of services. The information contained in this report is relevant to the date on which the site visit was performed and may not represent conditions at a later date (especially if new materials are later installed). This report has been prepared on behalf of and exclusively for use by the Client for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding any quantities listed, further investigation, or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
APPENDIX A
ASBESTOS INSPECTION SAMPLE LOCATION SUMMARY
Responsive ■ Resourceful ■ Reliable B-1
APPENDIX A
PROJECT: ACAD - REHABILITATE SCHOODIC
WATER AND WASTEWATER SYSTEMS
Acadia National Park
Schoodic Institute
Winter Harbor, Maine 04693
Asbestos Inspection Sample Location Summary
HA No. Sample Number Material Description Sample Location
Lab Results
PLM
TEM Gravimetric Reduction (for non-friable organically bound
(NOB) material samples)
1A Black Pipe Gasket Eliot Hall Basement, Pump
Room None Detected None Detected
1B Black Pipe Gasket Eliot Hall Basement, Pump
Room None Detected None Detected
1C Black Pipe Gasket Eliot Hall Basement, Pump
Room None Detected None Detected
2A Patch Cement Eliot Hall Basement, Pump
Room, Between Brick and Pipe None Detected Not Applicable
2B Patch Cement Eliot Hall Basement, Pump
Room, Between Brick and Pipe None Detected Not Applicable
2C Patch Cement Eliot Hall Basement, Pump
Room, Between Brick and Pipe None Detected Not Applicable
3A Smooth Penetration
Cement
Eliot Hall Basement, Pump
Room, North Wall None Detected Not Applicable
3B Smooth Penetration
Cement
Eliot Hall Basement, Pump
Room, North Wall None Detected Not Applicable
Responsive ■ Resourceful ■ Reliable B-2
Lab Results
PLM
TEM Gravimetric Reduction (for non-friable organically bound
(NOB) material samples)
3C Smooth Penetration
Cement
Eliot Hall Basement, Pump
Room, North Wall None Detected Not Applicable
4A Rough Penetration
Cement
Eliot Hall Basement, Pump
Room, North Wall None Detected Not Applicable
4B Rough Penetration
Cement
Eliot Hall Basement, Pump
Room, North Wall None Detected Not Applicable
4C Rough Penetration
Cement
Eliot Hall Basement, Pump
Room, North Wall None Detected Not Applicable
5A Penetration Cement Eliot Hall Basement, Outside
Pump Room, South Wall None Detected Not Applicable
5B Penetration Cement Eliot Hall Basement, Outside
Pump Room, South Wall None Detected Not Applicable
5C Penetration Cement Eliot Hall Basement, Outside
Pump Room, South Wall None Detected Not Applicable
6A Brown Grease Eliot Hall Basement, Pump
Room, Inside Blue Pipe Cooler None Detected None Detected
6B Brown Grease Eliot Hall Basement, Pump
Room, Inside Blue Pipe Cooler None Detected None Detected
6C Brown Grease Eliot Hall Basement, Pump
Room, Inside Blue Pipe Cooler None Detected None Detected
7A Bomb Shelter
Cement
Eliot Hall Basement, Bomb
Shelter Room None Detected Not Applicable
7B Bomb Shelter
Cement
Eliot Hall Basement, Bomb
Shelter Room None Detected Not Applicable
7C Bomb Shelter
Cement
Eliot Hall Basement, Bomb
Shelter Room None Detected Not Applicable
08 8A Black Rope Eliot Hall Basement, Pump
Room None Detected Not Applicable
Responsive ■ Resourceful ■ Reliable B-3
Lab Results
PLM
TEM Gravimetric Reduction (for non-friable organically bound
(NOB) material samples)
8B Black Rope Eliot Hall Basement, Pump
Room None Detected Not Applicable
8C Black Rope Eliot Hall Basement, Pump
Room None Detected Not Applicable
9A Cement Well House, Foundation None Detected Not Applicable
9B Cement Well House, Foundation None Detected Not Applicable
9C Cement Well House, Foundation None Detected Not Applicable
10A Mortar Well House, Casing Opening None Detected Not Applicable
10B Mortar Well House, Casing Opening None Detected Not Applicable
10C Mortar Well House, Casing Opening None Detected Not Applicable
11A Gypsum Board Well House Walls None Detected Not Applicable
11B Gypsum Board Well House Walls None Detected Not Applicable
11C Gypsum Board Well House Walls None Detected Not Applicable
12A Fiberglass Backing
Paper Well House Walls and Ceiling None Detected Not Applicable
12B Fiberglass Backing
Paper Well House Walls and Ceiling None Detected Not Applicable
12C Fiberglass Backing
Paper Well House Walls and Ceiling None Detected Not Applicable
13A Red Gasket Well House, Lower Pipe, Gray
Flange None Detected None Detected
13B Red Gasket Well House, Lower Pipe, Gray
Flange None Detected None Detected
Responsive ■ Resourceful ■ Reliable B-4
Lab Results
PLM
TEM Gravimetric Reduction (for non-friable organically bound
(NOB) material samples)
13C Red Gasket Well House, Lower Pipe, Gray
Flange None Detected None Detected
14A Gray Pipe Thread
Caulk Well House, Pipe Threads None Detected None Detected
14B Gray Pipe Thread
Caulk Well House, Pipe Threads None Detected None Detected
14C Gray Pipe Thread
Caulk Well House, Pipe Threads None Detected None Detected
15A Red Gasket Well House, Upper Pipe, Hexagonal Flange None Detected None Detected
15B Red Gasket Well House, Upper Pipe, Hexagonal Flange None Detected None Detected
15C Red Gasket Well House, Upper Pipe, Hexagonal Flange None Detected None Detected
16A White Thread Sealant Well House, Upper Pipe, Below
Meter None Detected None Detected
16B White Thread Sealant Well House, Upper Pipe, Below
Meter None Detected None Detected
16C White Thread Sealant Well House, Upper Pipe, Below
Meter None Detected None Detected
17A Roof Shingle Well House Roof None Detected None Detected
17B Roof Shingle Well House Roof None Detected None Detected
17C Roof Shingle Well House Roof None Detected None Detected
18A Vapor Barrier Well House Roof None Detected None Detected
18B Vapor Barrier Well House Roof None Detected None Detected
18C Vapor Barrier Well House Roof None Detected None Detected
APPENDIX B
SAMPLE LOCATION DIAGRAMS
GENERAL BUILDING LAYOUT / SAMPLE LOCATIONS
Eliot Hall - Basement Winter Harbor, Maine B
77 Sundial Ave, Suite #401w Manchester, NH 03103
PH. (603) 647-9700 FAX. (864) 647-4432
J1215067
4/11/22
MAC
ACF
MAC
MAC
N.T.S.
Project Manager:
Drawn by:
Checked by:
Approved by:
Project No.
Scale:
File Name:
Date:
App.
VHB - Acadia
DIAGRAM PROVIDED BY CLIENT AND
ADAPTED FOR PROJECT USE. DRAWING
MAY HAVE NON-TERRACON RELATED
INFORMATION. TERRACON SAMPLE
NUMBERS ARE PROVIDED OVER CLIENT
SUPPLIED DRAWING AND IS FOR GENERAL
LOCATION ONLY.
1A-C
2A-C
6A-C
8A-C 4A-C
3A-C
5A-C
PC-3
7A
7B 7C
PC-1
PC-2
PC-4
Pump Room
Bomb Shelter
GENERAL BUILDING LAYOUT / SAMPLE LOCATIONS
Pumphouse Winter Harbor, Maine B
77 Sundial Ave, Suite #401w Manchester, NH 03103
PH. (603) 647-9700 FAX. (864) 647-4432
J1215067
4/11/22
MAC
ACF
MAC
MAC
N.T.S.
Project Manager:
Drawn by:
Checked by:
Approved by:
Project No.
Scale:
File Name:
Date:
App.
VHB – Acadia
DIAGRAM PROVIDED BY CLIENT AND
ADAPTED FOR PROJECT USE. DRAWING
MAY HAVE NON-TERRACON RELATED
INFORMATION. TERRACON SAMPLE
NUMBERS ARE PROVIDED OVER CLIENT
SUPPLIED DRAWING AND IS FOR GENERAL
LOCATION ONLY.
9A
9B
9C
10A
10B
10C
11A
11B
11C
12A
12B
12C
13A-C 14A-C
16A-C15A-C
17A
17B 17C
18C
18A
18B
PC-5
PC-6
APPENDIX C
PHOTOGRAPHIC DOCUMENTATION
Asbestos and Lead Paint Inspection Schoodic Institute, Acadia National Park Winter Harbor, ME
Photo 1 – Pump Room, Pipes Pictured Photo 2 – Pump Room, Pipes Pictured
Photo 3 – Pump Room, Pipes Pictured Photo 4 – Pump Room, Pipes Pictured
Photo 5 – Bomb Shelter Photo 6 – Outside Pump Room
Asbestos and Lead Paint Inspection Schoodic Institute, Acadia National Park Winter Harbor, ME
Photo 7 – Outside Pump House Photo 8 – Interior of Pipe House – Pipe Junction Pictured
Photo 9 – Interior of Pump House – Pump Hole
Photo 10 – Interior of Pump House, Pipe Gasket
Photo 11 – Interior of Pump House, Pipe Junction
Photo 12 – Roof of Pump House
APPENDIX D
LABORATORY ANALYTICAL DATA
EMSL Analytical, Inc.
161 John Roberts Road South Portland, ME 04106
Phone/Fax: (207) 517-6921 / (207) 517-6922 http://www.EMSL.com / portlandlab@emsl.com
JAWO50
622200326EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Attn:
Proj: ACAD Water and WW System Replacement/J1215067
Phone: (603) 647-9700
Fax: (603) 647-4432
Collected: 2/28/2022
Received: 3/02/2022
Analyzed: 3/09/2022
Adam Frey
Terracon Consultants, Inc.
77 Sundial Avenue
Suite 401-W
Manchester, NH 03103
Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00011A
Eliot Hall Basement, pipe room/Black pipe gasket
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedBlack
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBlack
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00021B
Eliot Hall Basement, pipe room/Black pipe gasket
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedBlack
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBlack
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00031C
Eliot Hall Basement, pipe room/Black pipe gasket
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedBlack
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBlack
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00042A
Eliot Hall basement, pipe room, between brick and pipe/Patch cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00052B
Eliot Hall basement, pipe room, between brick and pipe/Patch cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00062C
Eliot Hall basement, pipe room, between brick and pipe/Patch cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00073A
Eliot Hall basement, pipe room, north wall/Smooth penetration cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/09/2022 02:57PM Page 1 of 8
Phone/Fax: (207) 517-6921 / (207) 517-6922 http://www.EMSL.com / portlandlab@emsl.com
JAWO50
622200326EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00083B
Eliot Hall basement, pipe room, north wall/Smooth penetration cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00093C
Eliot Hall basement, pipe room, north wall/Smooth penetration cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00104A
Eliot Hall basement, pipe room, north wall/Rough penetration cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00114B
Eliot Hall basement, pipe room, north wall/Rough penetration cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00124C
Eliot Hall basement, pipe room, north wall/Rough penetration cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00135A
Eliot Hall basement, outside pipe room, south wall/Penetration cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00145B
Eliot Hall basement, outside pipe room, south wall/Penetration cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00155C
Eliot Hall basement, outside pipe room, south wall/Penetration cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
Test Report:EPAMultiTests-7.32.2.D Printed: 3/09/2022 02:57PM Page 2 of 8
Phone/Fax: (207) 517-6921 / (207) 517-6922 http://www.EMSL.com / portlandlab@emsl.com
JAWO50
622200326EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00166A
Eliot Hall basement, pipe room, inside blue pipe cooler/Brown grease
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedBrown
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBrown
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00176B
Eliot Hall basement, pipe room, inside blue pipe cooler/Brown grease
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedBrown
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBrown
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00186C
Eliot Hall basement, pipe room, inside blue pipe cooler/Brown grease
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedBrown
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBrown
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00197A
Eliot Hall basement, bomb shelter/Bomb shelter cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00207B
Eliot Hall basement, bomb shelter/Bomb shelter cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00217C
Eliot Hall basement, bomb shelter/Bomb shelter cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00228A
Eliot Hall basement, pipe room/Black rope
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00238B
Eliot Hall basement, pipe room/Black rope
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
Test Report:EPAMultiTests-7.32.2.D Printed: 3/09/2022 02:57PM Page 3 of 8
Phone/Fax: (207) 517-6921 / (207) 517-6922 http://www.EMSL.com / portlandlab@emsl.com
JAWO50
622200326EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00248C
Eliot Hall basement, pipe room/Black rope
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00259A
Well house, foundation/Cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00269B
Well house, foundation/Cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-00279C
Well house, foundation/Cement
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-002810A
Well house, mortar casing opening/Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-002910B
Well house, mortar casing opening/Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003010C
Well house, mortar casing opening/Mortar
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 0.0% 100.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003111A
Well house walls/Gypsum board
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 5.0% 95.0%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 3/09/2022 02:57PM Page 4 of 8
Phone/Fax: (207) 517-6921 / (207) 517-6922 http://www.EMSL.com / portlandlab@emsl.com
JAWO50
622200326EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003211B
Well house walls/Gypsum board
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 5.0% 95.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003311C
Well house walls/Gypsum board
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 5.0% 95.0%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003412A
Well house walls and ceiling/Fiberglass backing paper
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 80.0% 20.0%PLM Black None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003512B
Well house walls and ceiling/Fiberglass backing paper
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 80.0% 20.0%PLM Black None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003612C
Well house walls and ceiling/Fiberglass backing paper
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/07/2022 80.0% 20.0%PLM Black None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003713A
Well house, lower pipe, gray flange/Red gasket
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedRed
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedRed
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003813B
Well house, lower pipe, gray flange/Red gasket
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedRed
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedRed
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-003913C
Well house, lower pipe, gray flange/Red gasket
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedRed
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedRed
Test Report:EPAMultiTests-7.32.2.D Printed: 3/09/2022 02:57PM Page 5 of 8
Phone/Fax: (207) 517-6921 / (207) 517-6922 http://www.EMSL.com / portlandlab@emsl.com
JAWO50
622200326EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004014A
Well house, pipe threads/Gray pipe thread caulk
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedGray
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedGray
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004114B
Well house, pipe threads/Gray pipe thread caulk
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedGray
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedGray
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004214C
Well house, pipe threads/Gray pipe thread caulk
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedGray
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedGray
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004315A
Well house, upper pipe, hexagonal flange/Red gasket
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedRed
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedRed
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004415B
Well house, upper pipe, hexagonal flange/Red gasket
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedRed
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedRed
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004515C
Well house, upper pipe, hexagonal flange/Red gasket
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedRed
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedRed
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004616A
Well house, upper pipe, below meter/White thread sealant
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedWhite
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedWhite
Test Report:EPAMultiTests-7.32.2.D Printed: 3/09/2022 02:57PM Page 6 of 8
Phone/Fax: (207) 517-6921 / (207) 517-6922 http://www.EMSL.com / portlandlab@emsl.com
JAWO50
622200326EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004716B
Well house, upper pipe, below meter/White thread sealant
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedWhite
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedWhite
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004816C
Well house, upper pipe, below meter/White thread sealant
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedWhite
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedWhite
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-004917A
Well house roof/Roof shingle
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 15.5% 84.5%PLM Grav. Reduction None DetectedBlack/Green
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBlack/Green
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-005017B
Well house roof/Roof shingle
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 15.2% 84.8%PLM Grav. Reduction None DetectedBlack/Green
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBlack/Green
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-005117C
Well house roof/Roof shingle
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 15.7% 84.3%PLM Grav. Reduction None DetectedBlack/Green
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBlack/Green
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-005218A
Well house roof/Black roof paper/vapor barrier
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedBlack
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBlack
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-005318B
Well house roof/Black roof paper/vapor barrier
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedBlack
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBlack
Test Report:EPAMultiTests-7.32.2.D Printed: 3/09/2022 02:57PM Page 7 of 8
Phone/Fax: (207) 517-6921 / (207) 517-6922 http://www.EMSL.com / portlandlab@emsl.com
JAWO50
622200326EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis of Bulk Material via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 622200326-005418C
Well house roof/Black roof paper/vapor barrier
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
3/09/2022 0.0% 100%PLM Grav. Reduction None DetectedBlack
3/09/2022 0.0% 100.0%TEM Grav. Reduction None DetectedBlack
PLM: ME CERT #BA-0178
PLM EPA NOB: ME CERT #BA-0197
TEM EPA NOB: ME CERT #BA-0197
Analyst(s):
PLM (30)Stephen Severn
PLM Grav. Reduction (24)
TEM Grav. Reduction (24)
Thomas Stegeman
Samantha Voigt, Laboratory Manager or Other Approved Signatory
Reviewed and approved by:
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. This test report must not be used to claim product endorsement by NVLAP or any agency of the U.S.
Government. EMSL bears no responsibility for sample collection activities or analytical method limitations. The laboratory is not responsible for the accuracy of results when requested to physically separate and analyze layered samples. PLM alone is not consistently reliable in detecting asbestos in floor coverings and similar NOBs
Samples analyzed by EMSL Analytical, Inc. South Portland, ME NVLAP Lab Code 500094-0, VT AL197271, ME LM-0039, CT PH-0346 Initial report from: 03/09/202214:57:26
Test Report:EPAMultiTests-7.32.2.D Printed: 3/09/2022 02:57PM Page 8 of 8
OrderID: 622200326
OrderID: 622200326
Client Sample Description ConcentrationLab ID Analyzed Weight Lead
Collected
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com
Attn: Adam Frey Terracon Consultants, Inc.
77 Sundial Avenue Suite 401-W Manchester, NH 03103
Received: 3/3/2022 10:30 AM
ACAD Water and WW System Replacement / J1215067
Fax: (603) 647-4432 Phone: (603) 647-9700
Project:
2/28/2022Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
202202356 CustomerID: JAWO50 CustomerPO: J1215067 ProjectID:
EMSL Order:
0.0655 Site: Eliot Hall Basement - Pump Room - Blue Pump Coolers
202202356-0001PC-1 0.94 % wt3/10/2022 g2/28/2022
0.2826 Site: Eliot Hall Basement - Pump Room - Black/Red Pipes
202202356-0002PC-2 3.6 % wt3/10/2022 g2/28/2022
0.2600 Site: Eliot Hall Basement - Outside Pump Room - Light Yellow CMU Walls
202202356-0003PC-3 2.2 % wt3/10/2022 g2/28/2022
0.2517 Site: Eliot Hall Basement - Bomb Shelter - White Walls
202202356-0004PC-4 0.14 % wt3/10/2022 g2/28/2022
0.0591 Site: Well House - Gray Door of Well House
202202356-0005PC-5 <0.034 % wt3/10/2022 g2/28/2022
0.2628 Site: Well House - Electric/Wood Panel
202202356-0006PC-6 <0.0080 % wt3/10/2022 g2/28/2022
Owen Mckenna, Lead Lab Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 3/11/2022 2:25:08 PM
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.
* Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01
Initial report from 03/11/2022 14:25:08 http://www.EMSL.com mailto:cinnaminsonleadlab@emsl.com
OrderID: 202202356
OrderID: 202202356