ELECTRICAL ABBREVIATIONS
AFF ABOVE FINISHED FLOOR
A AMPERES
ARCH ARCHITECT
C CONDUIT
EX EXISTING
EXT EXTERIOR
FA FIRE ALARM
FURN FURNITURE
GFI GROUND-FAULT CIRCUIT
INTERRUPTER
GFCI GROUND-FAULT CIRCUIT
INTERRUPTER
GND GROUND
IG ISOLATED GROUND
JB JUNCTION BOX
MECH MECHANICAL
NTS NOT TO SCALE
OC ON-CENTER
PLMB PLUMBING
PROV PROVIDED BY
SFC SURFACE MOUNTED
TP TAMPER PROOF
V VOLTS
W/ WITH
WP WEATHERPROOF AND
RATED FOR EXTERIOR
TEMPERATURES
WR WEATHER-RESISTANT
RECEPTACLE
LIGHTING SYMBOL LEGEND
SYMBOL TYPICAL
HEIGHT DESCRIPTION
HEIGHTS ARE TO THE BOTTOM OF THE DEVICE UNLESS NOTED OTHERWISE.
TOP: HEIGHT TO THE TOP OF THE DEVICE
BOTTOM: HEIGHT TO THE BOTTOM OF THE DEVICE.
HEIGHTS ARE TYPICAL AND MAY BE SUPERCEDED BY PLANS.
TOGGLE SWITCH
SWITCH MODIFIERS:
2: DOUBLE-POLE SWITCH
3: THREE-WAY
4: FOUR-WAY
S: OCCUPANCY SENSOR (AUTO ON/AUTO OFF)
V: VACANCY SENSOR (MANUAL ON/AUTO OFF)
L: LOW VOLTAGE SWITCH. PROVIDE COMPATIBLE POWER
PACK AS REQUIRED.
D: DIMMING (SUITABLE FOR DIMMING TECHNOLOGY)
T: DIGITAL TIMER, ADJUSTABLE TO 12 HOURS
WP: IN WEATHERPROOF ENCLOSURE
MODIFIERS MAY BE COMBINED. (E.G. "LVD" IS A LOW
VOLTAGE, DIMMING SWITCH WITH VACANCY SENSOR.)
CEILING/WALL SENSOR. PROVIDE POWER PACKS AND OTHER
ACCESSORIES AS REQUIRED BY LIGHTING CONTROL
TECHNOLOGY.
'S' TYPE SENSORS MUST BE CONFIGURED FOR AUTO
ON/AUTO OFF CONTROL.
'V' TYPE SENSORS MUST BE CONFIGURED FOR MANUAL
ON/AUTO OFF CONTROL.
CEILING SENSOR TYPES:
S1: LOW-VOLTAGE DUAL TECHNOLOGY MOTION SENSOR
FOR CORRIDOR APPLICATIONS. AUTO OFF CONTROL
SETTING MUST DIM TO 25%-50%.
S2/V2: LOW-VOLTAGE 360° DUAL TECHNOLOGY MOTION
SENSOR FOR STANDARD COVERAGE.
S3/V3: LOW-VOLTAGE 360° DUAL TECHNOLOGY MOTION
SENSOR FOR EXTENDED COVERAGE.
S4/V4: LOW-VOLTAGE DUAL TECHNOLOGY MOTION SENSOR,
CORNER MOUNTED COVERAGE.
OVERHEAD LIGHTING FIXTURE (VARIOUS
SYMBOLS). TAG INDICATES FIXTURE TYPE
ACCORDING TO LIGHT FIXTURE SCHEDULE.
DOWNLIGHT OR PENDANT LIGHTING FIXTURE
(VARIOUS SYMBOLS). TAG INDICATES FIXTURE
TYPE ACCORDING TO LIGHT FIXTURE SCHEDULE.
WALL-MOUNTED LIGHTING FIXTURE (VARIOUS
SYMBOLS). TAG INDICATES FIXTURE TYPE
ACCORDING TO LIGHT FIXTURE SCHEDULE.
DIRECTIONAL LIGHT SUCH AS FLOOD OR TRACK
HEAD. TAG INDICATES FIXTURE TYPE ACCORDING
TO LIGHT FIXTURE SCHEDULE.
AS
INDICATED
AS
INDICATED
AS
INDICATED
POLE OR AREA LIGHT (VARIOUS SYMBOLS). TAG
INDICATES FIXTURE TYPE ACCORDING TO LIGHT
FIXTURE SCHEDULE.
EXIT LIGHT. WALL- OR CEILING- MOUNT AS SUITABLE FOR
THE APPLICATION. FACES AND CHEVRONS AS INDICATED.
FIXTURE TYPE ACCORDING TO LIGHT FIXTURE SCHEDULE.
COMBINATION EMERGENCY LIGHTING UNIT AND EXIT SIGN.
WALL- OR CEILING-MOUNT AS SUITABLE FOR THE
APPLICATION. FACES AND CHEVRONS AS INDICATED.
FIXTURE TYPE ACCORDING TO LIGHT FIXTURE SCHEDULE.
EMERGENCY LIGHTING UNIT. WALL- OR CEILING-MOUNT
AS SUITABLE FOR THE APPLICATION. FIXTURE TYPE
ACCORDING TO LIGHT FIXTURE SCHEDULE.
SLASHES OR HALF-SHADING INDICATES THE FIXTURE
MUST BE CONNECTED AS A NIGHT LIGHT, AHEAD OF ALL
SWITCHING AND OTHER CONTROL DEVICES (24-HOUR
OPERATION). TYPICAL OF VARIOUS LIGHT FIXTURE
SYMBOLS.
S
44"
---ALCR AUTOMATIC LOAD CONTROL RELAY (UL924 LISTED).
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
WORKMANSHIP MUST CONFORM TO NECA INSTALLATION STANDARDS INCLUDING NECA 1.
INSTALLATION MUST COMPLY WITH NATIONAL ELECTRICAL CODE, INTERNATIONAL BUILDING CODE, APPLICABLE UFCS AND ALL REQUIREMENTS OF THE LOCAL INSPECTOR (FURNISH INSPECTION CERTIFICATE). ALL WORK MUST BE BY LICENSED CONTRACTOR.
THE CONTRACTOR MUST REFER TO THE ARCHITECTURAL PLANS FOR FLOOR PLAN DIMENSIONS. DO NOT SCALE THESE DRAWINGS. THE LOCATION OF ALL WALL MOUNTED DEVICES, INCLUDING MOUNTING HEIGHTS, MUST BE COORDINATED WITH ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATION. COORDINATE LOCATIONS OF ALL LIGHT FIXTURES WITH THE REFLECTED CEILING PLANS. LIGHT FIXTURES INSTALLED IN MECHANICAL AREAS MUST AVOID MECHANICAL PIPING, EQUIPMENT, DUCTWORK, ETC.
THE CONTRACTOR MUST COORDINATE ANY AND ALL WORK WITH OTHER TRADES INVOLVED IN THE PROJECT, PRIOR TO INSTALLATION OF ELEC. EQUIPMENT, SO AS TO AVOID CONFLICTS DURING CONSTRUCTION AND TO ALLOW FOR OPTIMUM MAINTENANCE AND WORKING SPACE.
CONDUITS AND CABLES MUST BE CONCEALED WHEREVER POSSIBLE BY EITHER ROUTING ABOVE CEILING, IN INTERSTITIAL SPACES OR RUNNING EXPOSED IN UNFINISHED SPACES AS MUCH AS FEASIBLE. CONDUITS MAY BE RUN EXPOSED IN MECHANICAL AREAS OR OTHER AREAS NOT SUBJECT TO PUBLIC VIEW WHERE APPROVED BY THE OWNER. WHEREVER CONDUITS OR CABLES ARE APPROVED TO BE EXPOSED, CONDUITS AND CABLES MUST BE RUN PARALLEL OR PERPENDICULAR TO STRUCTURAL ELEMENTS AND MUST BE RUN AND BUNDLED IN GROUPS, AND THE INSTALLATION MUST BE NEAT AND ORDERLY. EVEN WHEN EXPOSED, CONDUITS AND CABLES MUST BE ROUTED TO MINIMIZE VIEW FROM PERSONNEL. SEAL ALL PENETRATIONS AIR TIGHT AROUND ALL CONDUITS PASSING THROUGH WALLS OR FLOORS USING APPROPRIATE PENETRATION PROTECTION WHEN PASSING INTO OR THROUGH RATED ASSEMBLIES.
ALL LIGHT FIXTURES MUST BE SUPPORTED INDEPENDENTLY OF THE SUSPENDED CEILING SYSTEM.
WHERE BRANCH CIRCUIT TOTAL LENGTH IS GREATER THAN FIFTY (50) FEET FROM THE PANELBOARD, SEE VOLTAGE DROP SCHEDULE.
ALL MOUNTING HEIGHTS ARE GIVEN TO THE BOTTOM OF THE DEVICE UNLESS NOTED OTHERWISE.
ALL FUSES, DISCONNECT SWITCHES, AND BREAKER SIZES, SHOWN FOR MECHANICAL EQUIPMENT, MUST BE VERIFIED BEFORE THE PURCHASE OR INSTALLATION
OF SAID EQUIPMENT, WITH THE EQUIPMENT SUPPLIER AND THE MECHANICAL CONTRACTOR.
ALL DISCONNECT SWITCHES ARE TO BE HEAVY DUTY FUSIBLE TYPE. FUSES MUST BE THE APPROPRIATE TYPE FOR THE LOAD SERVED. THE CONTRACTOR MUST COMPARE ALL INSTALLED EQUIPMENT NAMEPLATE INFORMATION WITH THE ELECTRICAL PLANS AND NOTIFY THE ENGINEER IMMEDIATELY WITH ANY DISCREPANCIES. THE CONTRACTOR MUST COORDINATE ALL FUSE SIZES WITH ACTUAL INSTALLED EQUIPMENT NAMEPLATE INFORMATION PRIOR TO PURCHASING OR INSTALLING FUSES. WHERE THE NAMEPLATE INFORMATION DOES NOT INDICATE AN OVERCURRENT PROTECTION SIZE OR MAXIMUM AMPACITY RATING, FUSES MUST BE INSTALLED AS INDICATED ON THE ELECTRICAL PLANS WHERE IN AGREEMENT WITH NAMEPLATE DATA.
THE CONTRACTOR MUST PROVIDE ALL NECESSARY DISCONNECTS, SWITCHES, AND RECEPTACLES UNDER THE BID AND MUST INCLUDE ALL NECESSARY CIRCUITS TO AND FINAL CONNECTIONS TO THE EQUIPMENT PROVIDED BY ALL SUPPLIERS, UNLESS NOTED OTHERWISE BY OTHER DISCIPLINES. COORDINATE CLOSELY.
ALL ELECTRICAL EQUIPMENT MUST BE INSTALLED SO THAT ALL CODE-REQUIRED AND MANUFACTURER-RECOMMENDED SERVICING CLEARANCES ARE MAINTAINED. INSTALLATIONS MUST FULLY COMPLY WITH NEC 110.26 AND NEC 408.18 FOR CLEARANCE REQUIREMENTS.
PROVIDE GROUNDING CONDUCTOR FOR ALL CIRCUITS PER N.E.C. GROUNDING SYSTEMS MUST MEET ALL REQUIREMENTS OF NEC 250.
THE CONTRACTOR MUST PATCH ANY WALL, CEILING, OR FLOOR OPENINGS AND PENETRATIONS RESULTING FROM DEMOLITION OR NEW WORK IN EXISTING AREAS. PATCH MUST MEET OR EXCEED THE STRUCTURE'S INTEGRITY AND FIRE RATING. FINISH MUST MATCH STRUCTURE'S FINISH.
ALL CIRCUITS MUST BE TESTED WITH 600 VOLT TESTER PRIOR TO ENERGIZING.
ALL WALL OUTLET BOXES, RECEPTACLES, SWITCHES, COVERPLATES, ETC. MUST BE COMMERCIAL SPECIFICATION GRADE, STANDARD OR HEAVY DUTY. SEE BOOK SPECIFICATIONS FOR ADDITIONAL DETAILS. VERIFY COLOR / MATERIALS FOR ALL DEVICES AND COVERPLATES PRIOR TO PURCHASE. PROVIDE LABEL FOR EACH DEVICE IDENTIFYING THE CIRCUIT SERVING THE DEVICE. VERIFY IF LABEL SHOULD BE ON INSIDE OR OUTSIDE FACE OF COVERPLATE WITH OWNER/TENANT.
IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE W/ ALL OTHER TRADES REGARDING VOLTAGES, LOADS, CIRCUIT BREAKERS, ETC. PRIOR
TO BEGINNING ANY WORK.
AS USED ON THESE DOCUMENTS, THE WORD "PROVIDE" MEANS TO FURNISH AND INSTALL THE ITEM OR EQUIPMENT AND MAKE THE FINAL CONNECTION AS
REQUIRED.
ALL PANELS MUST BE STANDARD COMMERCIAL GRADE FROM A REPUTABLE NATIONAL MANUFACTURER AS SPECIFIED IN BOOK SPECIFICATIONS OR ON PLANS.
PANELS MUST BE RATED AS INDICATED ON PANEL SCHEDULES.
CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, ABA, AND UFCS WHICH ARE APPLICABLE TO THIS
PROJECT REGARDLESS OF WHETHER ALL DETAILS ARE INDICATED ON PLANS.
CONTRACTOR MUST COMPLY WITH ALL APPLICABLE SEISMIC REQUIREMENTS.
ELECTRICAL BOXES AND WIRING MUST NOT BE RECESSED INTO OR PENETRATE STRUCTURAL COLUMNS. BOXES/CONDUITS MUST BE SURFACE MOUNTED TO
COLUMN AND/OR RECESSED IN STUD WALL WHERE POSSIBLE. COORDINATE WITH ARCHITECT.
ALL RECEPTACLES, SWITCHES, AND ELECTRICAL DEVICES REQUIRED TO BE ABA ACCESSIBLE MUST BE MOUNTED PER ANSI 117.1 SECTIONS 308 AND 309.
ALL EQUIPMENT CONNECTED TO OR ASSOCIATED WITH THE ELECTRICAL, FIRE ALARM OR TELECOM SYSTEMS OR OTHERWISE INCLUDED IN THE SCOPE OF WORK MUST BE LISTED AND LABELED BY A THIRD PARTY ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION.
CONTRACTOR MUST PROVIDE ROUGH-INS FOR ALL CONTRACTOR PROVIDED EQUIPMENT (INCLUDING SUB-CONTRACTED EQUIPMENT AS APPLICABLE) AND DEVICES LOCATED ON THESE PLANS IN ACCORDANCE WITH NEC, NFPA, AND MANUFACTURER REQUIREMENTS. UNLESS OTHERWISE NOTED, BOX PROVIDED MUST BE SUITABLE FOR AND SIZED FOR THE PURPOSE, WITH A MINIMUM 3/4" CONDUIT TO ACCESSIBLE LOCATION ABOVE CEILING OR CONDUIT SIZED AS APPROPRIATE
FOR THE DEVICE IN QUESTION.
GENERAL NOTES AND REQUIREMENTS
NOTE:
THIS SCHEDULE APPLIES TO 15 AND 20 AMP BRANCH CIRCUITS
AT THE VOLTAGES INDICATED. CONDUCTOR SIZES INDICATED
IN GENERAL NOTES AND CONNECTIONS SCHEDULES ARE
MINIMUM SIZES. CONTRACTOR MUST UPSIZE CONDUCTORS
(LINE, NEUTRAL, AND GROUND) BASED ON LOAD AND LENGTH
OF RUN AS INDICATED IN SCHEDULE ABOVE.
VOLTAGE DROP SCHEDULE
120 VOLT BRANCH CIRCUITS UP TO 8 AMPS (<0.96 KVA)
RUN DISTANCE IN FEET CONDUCTOR SIZE (AWG)
1' #12 111' #10 181' #8 286' #6
120 VOLT BRANCH CIRCUITS 9 AMPS TO 14 AMPS (1- 1.68 KVA)
RUN DISTANCE IN FEET
1' #12 66' #10 101' #8 166' #6
277 VOLT BRANCH CIRCUITS UP TO 14 AMPS (<3.9 KVA)
RUN DISTANCE IN FEET
1' #12 151' #10 236' #8 381' #6
65' 100' 165' 260'
150' 235' 380' 600'
110' 180' 285' 450'
CONDUCTOR SIZE (AWG)
CONDUCTOR SIZE (AWG)
POWER SYMBOL LEGEND
SYMBOL TYPICAL
HEIGHT DESCRIPTION
NEMA 5-20R DUPLEX RECEPTACLE
NEMA 5-20R QUADRAPLEX RECEPTACLE
RECEPTACLE MODIFIERS (CAN APPLY TO ANY
RECEPTACLE TYPE):
G: GROUND-FAULT CURRENT INTERRUPTER
A: 3" ABOVE COUNTER OR BACKSPLASH
WP: WEATHERPROOF IN-USE ENCLOSURE
WR: WEATHER RESISTANT
C: FLUSH IN CEILING TILE
U: INTEGRAL USB TYPE A CHARGER
NOTE: MODIFIERS MAY BE COMBINED (E.G. 'AG' IS A
COMBINATION OF 'A' AND 'G'.)
TV: MOUNTED IN A/V BACKBOX. COORDINATE EXACT
HEIGHT WITH A/V DRAWINGS.
POWER RECEPTACLE, NEMA CONFIGURATION
AS NOTED
JUNCTION BOX, WALL-MOUNTED, PURPOSE AS NOTEDJ
POWER TRANSFORMER, WITH HOUSEKEEPING PAD
18"
18"
18"
18"
PANELBOARD OR OTHER ELECTRICAL EQUIPMENT
DISCONNECT SWITCH, FUSED
TOGGLE SWITCH44"
BOTTOM
SWITCH MODIFIERS:
M: MOTOR-RATED
HEIGHTS ARE TO THE BOTTOM OF THE DEVICE UNLESS NOTED OTHERWISE.
TOP: HEIGHT TO THE TOP OF THE DEVICE
BOTTOM: HEIGHT TO THE BOTTOM OF THE DEVICE.
HEIGHTS ARE TYPICAL AND MAY BE SUPERCEDED BY PLANS.
CIRCUIT WIRE. FUNCTION AS INDICATED ON PLANS.---
CIRCUIT WIRE. CONDUCTORS SHALL MATCH THAT OF THE
ASSOCIATED HOMERUN.
HOMERUN TO PANEL/BRANCH CIRCUIT CONNECTION.
SHORT TICKS REPRESENT PHASE CONDUCTORS. LONG
TICKS REPRESENT GROUNDED CONDUCTORS.
EQUIPMENT GROUNDING CONDUCTOR IS NOT SHOWN
BUT ALWAYS REQUIRED. MINIMUM SIZE PER NEC BASED
ON CIRCUIT BREAKER, SCHEDULE, AND VOLTAGE DROP
TABLE.
JUNCTION BOX, ABOVE OR ON CEILING,
PURPOSE AS NOTED
J --
NEMA 5-20R DUPLEX RECEPTACLE, SPLIT-CIRCUIT:
BOTTOM RECEPTACLE SWITCHED, TOP UNSWITCHED.
18"
FLOORBOX SYMBOL LEGEND
SYMBOL DESCRIPTION
FLUSH FLOOR BOX - IN-SLAB TYPE. PROVIDE QUADPLEX,
TELEPHONE, DATA, AND AV PLATES. PROVIDE (1) 3/4" CONDUIT
FOR POWER WITH PULL WIRE. SEE TELECOMMUNICATIONS
PLANS FOR TELECOMMUNICATIONS REQUIREMENTS.
F1
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
EL
EC
TR
IC
AL
N
O
TE
S
AN
D L
EG
EN
D S
E-001
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917082
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
G40" G40" G40"
J
J
J
J
J
J
J
F1
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
POWER NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE DROP SCHEDULE FOR WIRE SIZING INFORMATION FOR ALL
BRANCH CIRCUITS OVER 65' IN LENGTH.
ALL RECEPTACLES WITHIN 6 FEET FROM THE OUTSIDE EDGE OF ANY SINK
MUST BE GFI PER NEC 210.8(B)(5).
LOCATE ALL DEVICES, EQUIPMENT, AND/OR JUNCTION BOXES REQUIRING
ACCESS IN ACCESSIBLE LOCATIONS. AT HARD CEILING AREAS, COORDINATE
ANY ACCESS HATCHES WITH ARCHITECT PRIOR TO INSTALLATION AND
ROUGH-IN. TYPICALLY, ELECTRICAL DEVICES, ETC REQUIRING ACCESS MUST
AVOID HARD CEILING AREAS OR MUST SHARE ACCESS POINTS WITH
SUPPLIED MECHANICAL/PLUMBING EQUIPMENT (DISCONNECTS, ETC).
SEE ARCHITECTURAL SHEETS FOR INDICATIONS OF RATED WALLS.
PROVIDE LABEL PRINTER TYPE LABELING FOR ALL RECEPTACLES INDICATING
SOURCE FEED WITH PANEL AND CIRCUIT NUMBER.
PROVIDE MACHINE ENGRAVED PLACARD LABELING ATTACHED WITH RIVETS
TO ALL DISCONNECTS, PANELS, AND MOTOR-DISCONNECT SWITCHES
INDICATING EQUIPMENT NAME, VOLTAGE AND PHASE, AMPERAGE, HERTZ
AND SOURCE FEED.
ALL DISCONNECT SWITCHES MUST BE HEAVY DUTY TYPE.
CONTRACTOR MUST LOCATE JUNCTION BOXES, CONDUIT BODIES OR OTHER
EQUIPMENT OR FITTINGS ABOVE INACCESSIBLE CEILING SUCH THAT THEY
HAVE ACCESS PER NEC REQUIREMENTS.
REFERENCE EQUIPMENT CONNECTIONS SCHEDULE ON SHEET E-605.
G
CORRIDOR
DUTY
CORRIDOR
REG OFFICE
1ST BN OFF
2ND BN OFF
3RD BN OFF
COMM
CONFERENCE
BREAK
REG KTR
WOMEN
MEN
SPRINKLER
JAN
BUNK
ELECTRICAL
HOT MECH
MECHANICAL
MDP
L
P1C P1B
P1A
H1
G
G
G
G
G
G
GWP
GWR
G40" G40" G40"
G
GWP
E-401 A2
GWP
GWP
G
G44"
G44"
G
G
G
G
72"
G
P1B-19
P1B-21
P1B-27
P1B-25
P1A-19 P1A-21
P1A-25
P1B-23
P1A-23 P1A-17
P1A-15
P1A-1
P1A-3
P1A-5
P1A-7 P1A-9 P1A-11 P1A-13
P1A-27
P1A-22
P1B-9
W/GFI
T
72"
TA
TB
P1A-29 FMCP AMP BPS
P1C-6
P1C-4
W/LOCK
W/LOCK
W/LOCK
P1C-2
TRN
P1C-8
AREA B AREA CAREA A
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
FL
O
O R
P
LA
N
AR
EA
'A
P O
W
ER
E-101
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917083
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
PLAN NOTES
1 PROVIDE RELAY ABOVE CEILING FOR CONTROLLED RECEPTACLE
CONNECTION TO OCCUPANCY SENSOR. COORDINATE EXACT
REQUIREMENTS WITH EQUIPMENT SUPPLIER.
2 CONNECT FIRE ALARM PANELS. COORDINATE WITH FIRE PROTECTION.
3 DISCONNECT FOR TRANSFORMER SECONDARY FEED SERVING PANEL
'T'. SEE ELECTRICAL RISER DIAGRAM FOR DETAILS.
1/8" = 1'-0"
A3 FLOOR PLAN - AREA 'A' - POWER
1" = 60'-0"
A5 KEY PLAN - AREA 'A'
N
GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
POWER NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE DROP SCHEDULE FOR WIRE SIZING INFORMATION FOR ALL
BRANCH CIRCUITS OVER 65' IN LENGTH.
ALL RECEPTACLES WITHIN 6 FEET FROM THE OUTSIDE EDGE OF ANY SINK
MUST BE GFI PER NEC 210.8(B)(5).
LOCATE ALL DEVICES, EQUIPMENT, AND/OR JUNCTION BOXES REQUIRING
ACCESS IN ACCESSIBLE LOCATIONS. AT HARD CEILING AREAS, COORDINATE
ANY ACCESS HATCHES WITH ARCHITECT PRIOR TO INSTALLATION AND
ROUGH-IN. TYPICALLY, ELECTRICAL DEVICES, ETC REQUIRING ACCESS MUST
AVOID HARD CEILING AREAS OR MUST SHARE ACCESS POINTS WITH
SUPPLIED MECHANICAL/PLUMBING EQUIPMENT (DISCONNECTS, ETC).
SEE ARCHITECTURAL SHEETS FOR INDICATIONS OF RATED WALLS.
PROVIDE LABEL PRINTER TYPE LABELING FOR ALL RECEPTACLES INDICATING
SOURCE FEED WITH PANEL AND CIRCUIT NUMBER.
PROVIDE MACHINE ENGRAVED PLACARD LABELING ATTACHED WITH RIVETS
TO ALL DISCONNECTS, PANELS, AND MOTOR-DISCONNECT SWITCHES
INDICATING EQUIPMENT NAME, VOLTAGE AND PHASE, AMPERAGE, HERTZ
AND SOURCE FEED.
ALL DISCONNECT SWITCHES MUST BE HEAVY DUTY TYPE.
CONTRACTOR MUST LOCATE JUNCTION BOXES, CONDUIT BODIES OR OTHER
EQUIPMENT OR FITTINGS ABOVE INACCESSIBLE CEILING SUCH THAT THEY
HAVE ACCESS PER NEC REQUIREMENTS.
REFERENCE EQUIPMENT CONNECTIONS SCHEDULE ON SHEET E-605.
AREA B AREA CAREA A
44"
44"
44"
44"
44"
44"
44"
44"
44"
44"
44"
1ST MRB HQ CO ARMORY
AND MAINTENANCE BAY
2ND MRB HQ CO ARMORY
AND MAINTENANCE BAY
REGIMENTAL ARMORY
3RD MRB HQ CO ARMORY
AND MAINTENANCE BAY
CLEANING
CORRIDOR
CORRIDOR
P1C-9
P1C-11
P1C-13
P1C-17
P1C-19
P1C-21
P1C-23P1C-25
P1C-27
P1C-15
P1C-29
P1C-31 P1C-33
P1C-5
P1C-7
P1C-3P1C-1
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
FL
O
O R
P
LA
N
AR
EA
'B
P O
W
ER
E-102
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917084
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
PLAN NOTES
1" = 60'-0"
A5 KEY PLAN - AREA 'B'
1/8" = 1'-0"
A2 FLOOR PLAN - AREA 'B' - POWER GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
N
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
POWER NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE DROP SCHEDULE FOR WIRE SIZING INFORMATION FOR ALL
BRANCH CIRCUITS OVER 65' IN LENGTH.
ALL RECEPTACLES WITHIN 6 FEET FROM THE OUTSIDE EDGE OF ANY SINK
MUST BE GFI PER NEC 210.8(B)(5).
LOCATE ALL DEVICES, EQUIPMENT, AND/OR JUNCTION BOXES REQUIRING
ACCESS IN ACCESSIBLE LOCATIONS. AT HARD CEILING AREAS, COORDINATE
ANY ACCESS HATCHES WITH ARCHITECT PRIOR TO INSTALLATION AND
ROUGH-IN. TYPICALLY, ELECTRICAL DEVICES, ETC REQUIRING ACCESS MUST
AVOID HARD CEILING AREAS OR MUST SHARE ACCESS POINTS WITH
SUPPLIED MECHANICAL/PLUMBING EQUIPMENT (DISCONNECTS, ETC).
SEE ARCHITECTURAL SHEETS FOR INDICATIONS OF RATED WALLS.
PROVIDE LABEL PRINTER TYPE LABELING FOR ALL RECEPTACLES INDICATING
SOURCE FEED WITH PANEL AND CIRCUIT NUMBER.
PROVIDE MACHINE ENGRAVED PLACARD LABELING ATTACHED WITH RIVETS
TO ALL DISCONNECTS, PANELS, AND MOTOR-DISCONNECT SWITCHES
INDICATING EQUIPMENT NAME, VOLTAGE AND PHASE, AMPERAGE, HERTZ
AND SOURCE FEED.
ALL DISCONNECT SWITCHES MUST BE HEAVY DUTY TYPE.
CONTRACTOR MUST LOCATE JUNCTION BOXES, CONDUIT BODIES OR OTHER
EQUIPMENT OR FITTINGS ABOVE INACCESSIBLE CEILING SUCH THAT THEY
HAVE ACCESS PER NEC REQUIREMENTS.
REFERENCE EQUIPMENT CONNECTIONS SCHEDULE ON SHEET E-605.
AREA B AREA CAREA A
P2A
GWP
G
GWP
COMM
CORRIDOR
SALLY PORT
SALLY PORT
CORRIDOR
CO CAGE
CO CAGE
CO CAGE
CO CAGE
CO CAGE
CO CAGE
ELECTRICAL
E-401 A3
GWP
P2B
G44"
G44"
P2B-4 P2B-6 P2B-8 P2B-10
P2A-3 P2A-5 P2A-7 P2A-9 P2A-13 P2A-15 P2A-17 P2A-19 P2A-21 P2A-23 P2A-25 P2A-27 P2A-29 P2A-31
P2A-16 P2A-18 P2A-20 P2A-22 P2A-24 P2A-26 P2A-28 P2A-30 P2A-32 P2A-34 P2A-36 P2A-38 P2A-40 P2A-42
P2B-3 P2B-5 P2B-7 P2B-9 P2B-11 P2B-13 P2B-15 P2B-17 P2B-19 P2B-21 P2B-23 P2B-25 P2B-27 P2B-29
P2B-30P2B-28P2B-26P2B-24P2B-22P2B-20P2B-18P2B-16P2B-14P2B-12
P2A-11
P2B-33
P2B-32
H2
P2A-1
P2A-14
P2B-2
P2B-1
P2A-33
TC
UNISEX
UNISEX
CO CAGE
CO CAGE
CO CAGE
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
FL
O
O R
P
LA
N
AR
EA
'C
P O
W
ER
E-103
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917085
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
PLAN NOTES
1" = 60'-0"
A5 KEY PLAN - AREA 'C'
1/8" = 1'-0"
A1 FLOOR PLAN - AREA 'C' - POWER GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
N
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M M
POWER NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE DROP SCHEDULE FOR WIRE SIZING INFORMATION FOR ALL
BRANCH CIRCUITS OVER 65' IN LENGTH.
ALL RECEPTACLES WITHIN 6 FEET FROM THE OUTSIDE EDGE OF ANY SINK
MUST BE GFI PER NEC 210.8(B)(5).
LOCATE ALL DEVICES, EQUIPMENT, AND/OR JUNCTION BOXES REQUIRING
ACCESS IN ACCESSIBLE LOCATIONS. AT HARD CEILING AREAS, COORDINATE
ANY ACCESS HATCHES WITH ARCHITECT PRIOR TO INSTALLATION AND
ROUGH-IN. TYPICALLY, ELECTRICAL DEVICES, ETC REQUIRING ACCESS MUST
AVOID HARD CEILING AREAS OR MUST SHARE ACCESS POINTS WITH
SUPPLIED MECHANICAL/PLUMBING EQUIPMENT (DISCONNECTS, ETC).
SEE ARCHITECTURAL SHEETS FOR INDICATIONS OF RATED WALLS.
PROVIDE LABEL PRINTER TYPE LABELING FOR ALL RECEPTACLES INDICATING
SOURCE FEED WITH PANEL AND CIRCUIT NUMBER.
PROVIDE MACHINE ENGRAVED PLACARD LABELING ATTACHED WITH RIVETS
TO ALL DISCONNECTS, PANELS, AND MOTOR-DISCONNECT SWITCHES
INDICATING EQUIPMENT NAME, VOLTAGE AND PHASE, AMPERAGE, HERTZ
AND SOURCE FEED.
ALL DISCONNECT SWITCHES MUST BE HEAVY DUTY TYPE.
CONTRACTOR MUST LOCATE JUNCTION BOXES, CONDUIT BODIES OR OTHER
EQUIPMENT OR FITTINGS ABOVE INACCESSIBLE CEILING SUCH THAT THEY
HAVE ACCESS PER NEC REQUIREMENTS.
REFERENCE EQUIPMENT CONNECTIONS SCHEDULE ON SHEET E-605.
AREA B AREA CAREA A
CORRIDOR
DUTY
CORRIDOR
REG OFFICE
1ST BN OFF
2ND BN OFF
3RD BN OFF
COMM
CONFERENCE
BREAK
REG KTR
WOMEN
MEN
SPRINKLER
JAN
BUNK
ELECTRICAL
HOT MECH
MECHANICAL
DCU-1
VAV-2-1
VAV-2-2
VAV-2-3
VAV-2-4
DAC-1
VAV-2-7
VAV-2-5
VAV-2-6
DAC-2
DCU-2
P1A-36,38
T-2,4
P1A-8
DAC-4 10
P1A-12
H1-37
DCU-4P1A-40,42
EF-3
T-6
SEE DETAIL A1
THIS SHEET FOR
ENLARGED PLAN
P1A-10
HOT MECH
MECHANICAL
AHU-2
AHU-1
CHWP-2
CHWP-1
DH-1
SHWP-2
SHWP-1
PHWP-1PHWP-2
B-2 B-1
VFD
VFD
VFD
VFD VFD
EUH-1
H1-1,3,5
H1-19,21,23
H1-13,15,17
H1-31,33,35H1-25,27,29
P1B-17
5 5
ELECTRICAL
CH-1
AC-1
H1-8,10,12
P1B-7
PHWP-3
B-3
P1B-5
P1B-1 P1B-3
P1A-14
MDP-1,3,5
GWP
P1B-11,13,15
P1A-2
P1A-4
P1A-16
EF-2
P1B-6 P1B-2 P1B-4
D-WH-1
H1-2,4,6
H1-7,9,11 P1A-20
AD-1
P1B-29 16
P1A-18
P1A-24
VFD VFD
P1A-26P1A-28
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
FL
O
O R
P
LA
N
AR
EA
'A
E Q
U
IP
M
EN
T C
O N
N
EC
TI
O
N S
E-104
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917086
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
# PLAN NOTES
1 CONNECT MOTORIZED DAMPER. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH
MECHANICAL.
2 CONNECT VAV. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
3 CONNECT BOILER. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
4 CONNECT UNIT HEATER. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
5 CONNECT PUMP THROUGH VFD. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH
MECHANICAL.
6 CONNECT AIR HANDLER WITH MULTI-POINT CONNECTION THRU VFD. PROVIDE DISCONNECTS, WIRING, AND CONDUIT
COMPLETE. COORDINATE WITH MECHANICAL.
7 CONNECT DEHUMIDIFIER. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
8 CONNECT PUMP. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
9 CONNECT CONDENSATE PUMP. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH
MECHANICAL.
10 CONNECT DUCTLESS SPLIT AIR HANDLING UNIT. INDOOR UNIT IS POWERED BY OUTDOOR UNIT. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
11 CONNECT EXHAUST FAN. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
12 CONNECT AIR COMPRESSOR. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH PLUMBING.
13 CONNECT HVAC CONTROL PANEL. COORDINATE WITH MECHANICAL.
14 CONNECT CHILLER. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
15 CONNECT DUCTLESS SPLIT CONDENSING UNIT. INDOOR UNIT IS POWERED BY OUTDOOR UNIT. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
16 CONNECT AIR DRYER. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
17 CONNECT GAS WATER HEATER. PROVIDE DISCONNECT, CONDUCTORS AND CONDUITS COMPLETE. COORDINATE WITH
PLUMBING.
18 CONNECT RECIRCULATING PUMP. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE. COORDINATE WITH
PLUMBING.
19 CONNECT AIR HANDLING UNIT RECIRCULATION PUMP. PROVIDE DISCONNECT, WIRING, AND CONDUIT COMPLETE.
COORDINATE WITH MECHANICAL.
1" = 60'-0"
A5 KEY PLAN - AREA 'A' 1/8" = 1'-0"
A3 FLOOR PLAN - AREA 'A' - EQUIPMENT CONNECTIONS
GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
N
3/16" = 1'-0"
A1 ENLARGED FLOOR PLAN - AREA 'A' - EQUIPMENT CONNECTIONS
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
M
M
M M
M
M
M
M
POWER NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE DROP SCHEDULE FOR WIRE SIZING INFORMATION FOR ALL
BRANCH CIRCUITS OVER 65' IN LENGTH.
ALL RECEPTACLES WITHIN 6 FEET FROM THE OUTSIDE EDGE OF ANY SINK
MUST BE GFI PER NEC 210.8(B)(5).
LOCATE ALL DEVICES, EQUIPMENT, AND/OR JUNCTION BOXES REQUIRING
ACCESS IN ACCESSIBLE LOCATIONS. AT HARD CEILING AREAS, COORDINATE
ANY ACCESS HATCHES WITH ARCHITECT PRIOR TO INSTALLATION AND
ROUGH-IN. TYPICALLY, ELECTRICAL DEVICES, ETC REQUIRING ACCESS MUST
AVOID HARD CEILING AREAS OR MUST SHARE ACCESS POINTS WITH
SUPPLIED MECHANICAL/PLUMBING EQUIPMENT (DISCONNECTS, ETC).
SEE ARCHITECTURAL SHEETS FOR INDICATIONS OF RATED WALLS.
PROVIDE LABEL PRINTER TYPE LABELING FOR ALL RECEPTACLES INDICATING
SOURCE FEED WITH PANEL AND CIRCUIT NUMBER.
PROVIDE MACHINE ENGRAVED PLACARD LABELING ATTACHED WITH RIVETS
TO ALL DISCONNECTS, PANELS, AND MOTOR-DISCONNECT SWITCHES
INDICATING EQUIPMENT NAME, VOLTAGE AND PHASE, AMPERAGE, HERTZ
AND SOURCE FEED.
ALL DISCONNECT SWITCHES MUST BE HEAVY DUTY TYPE.
CONTRACTOR MUST LOCATE JUNCTION BOXES, CONDUIT BODIES OR OTHER
EQUIPMENT OR FITTINGS ABOVE INACCESSIBLE CEILING SUCH THAT THEY
HAVE ACCESS PER NEC REQUIREMENTS.
REFERENCE EQUIPMENT CONNECTIONS SCHEDULE ON SHEET E-605.
AREA B AREA CAREA A
1ST MRB HQ CO ARMORY
AND MAINTENANCE BAY
2ND MRB HQ CO ARMORY
AND MAINTENANCE BAY
3RD MRB HQ CO ARMORY
AND MAINTENANCE BAY
CLEANING
CORRIDOR
CORRIDOR
VAV-1-11VAV-1-6
VAV-2-8
VAV-1-1
VAV-1-16
3 3
H1-39
EF-1
P1A-6
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
FL
O
O R
P
LA
N
AR
EA
'B
E Q
U
IP
M
EN
T C
O N
N
EC
TI
O
N S
E-105
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917087
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
PLAN NOTES
1 CONNECT MOTORIZED DAMPER. PROVIDE DISCONNECT, WIRING, AND
CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
2 CONNECT EXHAUST FAN. PROVIDE DISCONNECT, WIRING, AND CONDUIT
COMPLETE. COORDINATE WITH MECHANICAL.
3 CONNECT VAV. PROVIDE DISCONNECT, WIRING, AND CONDUIT
COMPLETE. COORDINATE WITH MECHANICAL.
1" = 60'-0"
A5 KEY PLAN - AREA 'B'
1/8" = 1'-0"
A2 FLOOR PLAN - AREA 'B' - EQUIPMENT CONNECTIONS GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
N
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
M
M
M
M M M
M
M M
M
M
M
M
M M
M
M
M
POWER NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE DROP SCHEDULE FOR WIRE SIZING INFORMATION FOR ALL
BRANCH CIRCUITS OVER 65' IN LENGTH.
ALL RECEPTACLES WITHIN 6 FEET FROM THE OUTSIDE EDGE OF ANY SINK
MUST BE GFI PER NEC 210.8(B)(5).
LOCATE ALL DEVICES, EQUIPMENT, AND/OR JUNCTION BOXES REQUIRING
ACCESS IN ACCESSIBLE LOCATIONS. AT HARD CEILING AREAS, COORDINATE
ANY ACCESS HATCHES WITH ARCHITECT PRIOR TO INSTALLATION AND
ROUGH-IN. TYPICALLY, ELECTRICAL DEVICES, ETC REQUIRING ACCESS MUST
AVOID HARD CEILING AREAS OR MUST SHARE ACCESS POINTS WITH
SUPPLIED MECHANICAL/PLUMBING EQUIPMENT (DISCONNECTS, ETC).
SEE ARCHITECTURAL SHEETS FOR INDICATIONS OF RATED WALLS.
PROVIDE LABEL PRINTER TYPE LABELING FOR ALL RECEPTACLES INDICATING
SOURCE FEED WITH PANEL AND CIRCUIT NUMBER.
PROVIDE MACHINE ENGRAVED PLACARD LABELING ATTACHED WITH RIVETS
TO ALL DISCONNECTS, PANELS, AND MOTOR-DISCONNECT SWITCHES
INDICATING EQUIPMENT NAME, VOLTAGE AND PHASE, AMPERAGE, HERTZ
AND SOURCE FEED.
ALL DISCONNECT SWITCHES MUST BE HEAVY DUTY TYPE.
CONTRACTOR MUST LOCATE JUNCTION BOXES, CONDUIT BODIES OR OTHER
EQUIPMENT OR FITTINGS ABOVE INACCESSIBLE CEILING SUCH THAT THEY
HAVE ACCESS PER NEC REQUIREMENTS.
REFERENCE EQUIPMENT CONNECTIONS SCHEDULE ON SHEET E-605.
AREA B AREA CAREA A
COMM
CORRIDOR
SALLY PORT
SALLY PORT
136CORRIDOR
CO CAGE
CO CAGE
CO CAGE
CO CAGE
CO CAGE
CO CAGE
ELECTRICAL
DCU-3
VAV-1-3
VAV-1-2
VAV-1-4
VAV-1-13
VAV-1-8
VAV-1-14
VAV-1-9
VAV-1-12
VAV-1-7
VAV-1-17 VAV-1-18 VAV-1-10
DAC-3
D-WH-2
D-WH-2
H2-25
H2-23
VAV-1-15
H2-29
VAV-1-5
DAC-5
DCU-5
P2A-35,37
P2A-39
T2-2,4
H2-27
EF-4
P2A-41
EF-5
P2B-31
T2-6
4 4
6 5
UNISEX
UNISEX
CO CAGE
CO CAGE
CO CAGE
44 44 4 4
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
FL
O
O R
P
LA
N
AR
EA
'C
E Q
U
IP
M
EN
T C
O N
N
EC
TI
O
N S
E-106
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917088
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
PLAN NOTES
1 CONNECT DUCTLESS SPLIT CONDENSING UNIT. INDOOR UNIT IS
POWERED BY OUTDOOR UNIT. PROVIDE DISCONNECT, WIRING, AND
CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
2 CONNECT DUCTLESS SPLIT AIR HANDLING UNIT. INDOOR UNIT IS
POWERED BY OUTDOOR UNIT. PROVIDE DISCONNECT, WIRING, AND
CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
3 CONNECT CONDENSATE PUMP. PROVIDE DISCONNECT, WIRING, AND
CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
4 CONNECT VAV. PROVIDE DISCONNECT, WIRING, AND CONDUIT
COMPLETE. COORDINATE WITH MECHANICAL.
5 CONNECT EXHAUST FAN. PROVIDE DISCONNECT, WIRING, AND CONDUIT
COMPLETE. COORDINATE WITH MECHANICAL.
6 CONNECT MOTORIZED DAMPER. PROVIDE DISCONNECT, WIRING, AND
CONDUIT COMPLETE. COORDINATE WITH MECHANICAL.
7 CONNECT INSTANTANEOUS WATER HEATER. PROVIDE DISCONNECT,
CONDUCTORS AND CONDUITS COMPLETE. COORDINATE WITH
PLUMBING.
1" = 60'-0"
A5 KEY PLAN - AREA 'C'
1/8" = 1'-0"
A1 FLOOR PLAN - AREA 'C' - EQUIPMENT CONNECTIONS GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
N
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
D
D
D
D D
D D D
S2
S2
S2
S1 S1
S1
S1
S2
S2
S2
S2
3D
S2
S2
S2
S2
S2
S2
LIGHTING NOTES
1.
2.
3.
4.
5.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE DROP SCHEDULE FOR WIRE SIZING INFORMATION FOR ALL
BRANCH CIRCUITS OVER 65' IN LENGTH.
LOCATE ALL DEVICES, EQUIPMENT, AND/OR JUNCTION BOXES REQUIRING
ACCESS IN ACCESSIBLE LOCATIONS. AT HARD CEILING AREAS, COORDINATE
ANY ACCESS HATCHES WITH ARCHITECT PRIOR TO INSTALLATION AND
ROUGH-IN. TYPICALLY, ELECTRICAL DEVICES, ETC REQUIRING ACCESS MUST
AVOID HARD CEILING AREAS OR MUST SHARE ACCESS POINTS WITH
SUPPLIED MECHANICAL/PLUMBING EQUIPMENT (DISCONNECTS, ETC).
SEE ARCHITECTURAL SHEETS FOR INDICATIONS OF RATED WALLS.
PROVIDE LABEL PRINTER TYPE LABELING FOR ALL SWITCHES INDICATING
SOURCE FEED WITH PANEL AND CIRCUIT NUMBER.
A4
A4
A4
A4
A4
A4
A4
A4
A4A4
A4
A4
A4
A4
A4
A4 A4
A4 A4
B B
C
A4
A4A4
A4 A4
A4 A4 A4 A4
A4A4
DDD
D D D A4 A4
D
DD
D
D D D
D D D
CORRIDOR
DUTY
CORRIDOR
REG OFFICE
1ST BN OFF
2ND BN OFF
3RD BN OFF
COMM
CONFERENCE
BREAK
REG KTR
WOMEN
MEN
SPRINKLER
JAN
BUNK
ELECTRICAL
HOT MECH
MECHANICAL
D D D
C C
P P
P
JE
KE
C
C
B
D
D
JE
P
B
C C C
L-1
L-5 L-3
B
2 2
L-19
THRU
CONTACTOR
4 4
B
AREA B AREA CAREA A
D D D D D D D D D D
D D D D D D D D D D
D D D D D D D D D D
D D D D D D D D D D
D D D D D D D D D D
D D D D D D D D D D
D D D D D D D D D D
L-21
L-23
L-25
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
FL
O
O R
P
LA
N
AR
EA
'A
L
IG
H
TI
N G
E-107
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917089
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
PLAN NOTES
1 LOW VOLTAGE CEILING MOUNTED MOTION SENSOR. CONNECT TO ALL
LIGHTS IN THIS AREA. SEE MOTION SENSOR DETAIL.
2 CONNECT BATTERY IN LIGHT FIXTURE AHEAD OF CONTACTOR SO THAT
EMERGENCY BATTERY COMES ON ONLY IN THE EVENT OF POWER
LOSS. FIXTURE IS NORMALLY CONTROLLED BY EXTERIOR LIGHTING
TIMECLOCK.
3 CONNECT FIXTURE TO FUNCTION AS A NIGHT LIGHT AHEAD OF LOCAL
SWITCH. (TOTAL FIXTURE UNSWITCHED).
4 CONNECT ALL EMERGENCY LIGHTS AND EXIT SIGNS SHOWN IN THIS
AREA TO CIRCUIT #L-2 ON LOCKED BREAKER.
1/8" = 1'-0"
A3 FLOOR PLAN - AREA 'A' - LIGHTING
1" = 60'-0"
A5 KEY PLAN - AREA 'A'
GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16' N
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
1/16" = 1'-0"
B1 ATTIC PLAN - LIGHTING
SEE SHEET E-601 FOR LIST OF ROOMS
CONTAINING CONTROLLED RECEPTACLES.
COORDINATE OCCUPANCY SENSOR
CONTROLS WITH LIGHTING AND RECEPTACLE
CONTROLS.
OCCUPANCY SENSOR NOTE
3D 3
3D 3D
3D
S3S3
S3 S3
S3 S3
S3 S3
S1 S1
S1 S1
S3
S3
S3
S3
S3
3D
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
SD
SD
SD
SD
S1
S1
ALCR
ALCR
LIGHTING NOTES
1.
2.
3.
4.
5.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE DROP SCHEDULE FOR WIRE SIZING INFORMATION FOR ALL
BRANCH CIRCUITS OVER 65' IN LENGTH.
LOCATE ALL DEVICES, EQUIPMENT, AND/OR JUNCTION BOXES REQUIRING
ACCESS IN ACCESSIBLE LOCATIONS. AT HARD CEILING AREAS, COORDINATE
ANY ACCESS HATCHES WITH ARCHITECT PRIOR TO INSTALLATION AND
ROUGH-IN. TYPICALLY, ELECTRICAL DEVICES, ETC REQUIRING ACCESS MUST
AVOID HARD CEILING AREAS OR MUST SHARE ACCESS POINTS WITH
SUPPLIED MECHANICAL/PLUMBING EQUIPMENT (DISCONNECTS, ETC).
SEE ARCHITECTURAL SHEETS FOR INDICATIONS OF RATED WALLS.
PROVIDE LABEL PRINTER TYPE LABELING FOR ALL SWITCHES INDICATING
SOURCE FEED WITH PANEL AND CIRCUIT NUMBER.
A7 A7
A7 A7
HA7A7A7A7A7
A7
A4
A4
A4A4A4A4
A4
A4
A7 A7
A7 A7
A7A7
A7 A7
A7 A7
A7A7
A7 A7
A7A7
A4
H
A4A4A4A4
A4 A7A7
A7 A7
A4
A7 A7
A4
A7A7
A7 A7
1ST MRB HQ CO ARMORY
AND MAINTENANCE BAY
2ND MRB HQ CO ARMORY
AND MAINTENANCE BAY
3RD MRB HQ CO ARMORY
AND MAINTENANCE BAY
CLEANING
CORRIDOR
CORRIDOR
A7 A7 A7 A7 A7 H
A7 A7 A7 A7 A7 H
HA7A7A7A7A7
A7
A7 A7
A7 A7
A7 A7
A7 A7
A7 H
H
A7 A7 A7 A7 A7 H
HA7A7A7A7A7
JE JE
JE JE
A4
H
H
H
P
P
A4
A7
1 1
L-11
L-9
L-13
L-152 2
2 2
L-7
HO
HO
HO
HO
AREA B AREA CAREA A
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
FL
O
O R
P
LA
N
AR
EA
'B
L
IG
H
TI
N G
E-108
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917090
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
PLAN NOTES
1 LOW VOLTAGE CEILING MOUNTED MOTION SENSOR. CONNECT TO ALL
LIGHTS IN THIS AREA. SEE MOTION SENSOR DETAIL.
2 CONNECT BATTERY IN LIGHT FIXTURE AHEAD OF CONTACTOR SO THAT
EMERGENCY BATTERY COMES ON ONLY IN THE EVENT OF POWER
LOSS. FIXTURE IS NORMALLY CONTROLLED BY EXTERIOR LIGHTING
TIMECLOCK.
4 CONNECT FIXTURE TO FUNCTION AS A NIGHT LIGHT AHEAD OF LOCAL
SWITCH. (TOTAL FIXTURE UNSWITCHED).
5 CONNECT ALL EMERGENCY LIGHTS AND EXIT SIGNS SHOWN IN THIS
AREA TO CIRCUIT #L-4 ON LOCKED BREAKER.
6 CONNECT ALL EMERGENCY LIGHTS AND EXIT SIGNS SHOWN IN THIS
AREA TO CIRCUIT #L-6 ON LOCKED BREAKER.
7 CONNECT ALCR AHEAD OF LIGHTING CONTROLS TO LIGHT FIXTURES IN
THIS AREA. COORDINATE WITH FIRE ALARM FOR CONNECTION TO FA
SYSTEM. ACTIVATION OF FA SYSTEM MUST OVERRIDE LIGHTING
CONTROLS FOR EGRESS ILLUMINATION. ALCR MUST BE UL924 LISTED.
1/8" = 1'-0"
A2 FLOOR PLAN - AREA 'B' - LIGHTING
1" = 60'-0"
A5 KEY PLAN - AREA 'B'
GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
N
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
S S
SD SD SD SD SD SD SD SD SD SD SD SD SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S1
S1
S
S
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
SD SD SD SD SD SD SD SD SD SD SD SD SD
SD
SD
SD
SD
S1 S1
S1
S1
S1 S1 S1
S1
S1 S1 S1 S1 S1
S1
ALCR
ALCR
LIGHTING NOTES
1.
2.
3.
4.
5.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE DROP SCHEDULE FOR WIRE SIZING INFORMATION FOR ALL
BRANCH CIRCUITS OVER 65' IN LENGTH.
LOCATE ALL DEVICES, EQUIPMENT, AND/OR JUNCTION BOXES REQUIRING
ACCESS IN ACCESSIBLE LOCATIONS. AT HARD CEILING AREAS, COORDINATE
ANY ACCESS HATCHES WITH ARCHITECT PRIOR TO INSTALLATION AND
ROUGH-IN. TYPICALLY, ELECTRICAL DEVICES, ETC REQUIRING ACCESS MUST
AVOID HARD CEILING AREAS OR MUST SHARE ACCESS POINTS WITH
SUPPLIED MECHANICAL/PLUMBING EQUIPMENT (DISCONNECTS, ETC).
SEE ARCHITECTURAL SHEETS FOR INDICATIONS OF RATED WALLS.
PROVIDE LABEL PRINTER TYPE LABELING FOR ALL SWITCHES INDICATING
SOURCE FEED WITH PANEL AND CIRCUIT NUMBER.
A4
P P
D
D
A4
COMM
CORRIDOR
SALLY PORT
SALLY PORT
CORRIDOR
CO CAGE
CO CAGE
CO CAGE
CO CAGE
CO CAGE
CO CAGE
ELECTRICAL
H H
HH
H
H
H
H P
PHHHH H
H
H H
H
H H
H
H H
H
H H
H
H H
H
H H
H
H H
H
H H
H
H H
H
H
PPPPPPPPPP
H H H H P H H H H H H H H H H
HHHHHHHHHHHHHH
H H H H P
H H H H H H H H H H
HHHHHHHHHHPHHHH
H H H H H H H H H H H H H H
HHHHHHHHHH
P
HHHH
H
P P P P P P P P P P
HHHHHHHHHHPHHH
H H H H P H H H H H H H H H H
HHHHHHHHHHHHHH
HO HO HO HO HO
HO HO HO HO HO
J
J
J
J
J
J
JE
JE
A4
A4
P P
CO CAGE
CO CAGE
CO CAGE
H
H
H
P
H
H
H
H
H
H
P
H
H
H
UNISEX
UNISEX
H2-1 H2-3
H2-5 H2-7
H2-9 H2-11
H2-15H2-13 H2-19
H2-17
L-17
HO
H2-21
THRU
CONTACTOR
4 4
5 5 5 5
4 4 4
5 5
HO
AREA B AREA CAREA A
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
FL
O
O R
P
LA
N
AR
EA
'C
L
IG
H
TI
N G
E-109
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917091
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
PLAN NOTES
1 CONNECT FIXTURE TO FUNCTION AS A NIGHT LIGHT AHEAD OF LOCAL
SWITCH. (TOTAL FIXTURE UNSWITCHED).
2 CONNECT BATTERY IN LIGHT FIXTURE AHEAD OF CONTACTOR SO THAT
EMERGENCY BATTERY COMES ON ONLY IN THE EVENT OF POWER
LOSS. FIXTURE IS NORMALLY CONTROLLED BY EXTERIOR LIGHTING
TIMECLOCK.
3 CONNECT TO EXTERIOR LIGHTING CIRCUIT THROUGH CONTACTOR. SEE
ES101 FOR ADDITIONAL CIRCUIT DETAILS.
4 CONNECT ALL EMERGENCY LIGHTS AND EXIT SIGNS SHOWN IN THIS
AREA TO CIRCUIT #L-8 ON LOCKED BREAKER.
5 CONNECT ALL EMERGENCY LIGHTS AND EXIT SIGNS SHOWN IN THIS
AREA TO CIRCUIT #L-10 ON LOCKED BREAKER.
6 CONNECT ALCR AHEAD OF LIGHTING CONTROLS TO LIGHT FIXTURES IN
THIS AREA. COORDINATE WITH FIRE ALARM FOR CONNECTION TO FA
SYSTEM. ACTIVATION OF FA SYSTEM MUST OVERRIDE LIGHTING
CONTROLS FOR EGRESS ILLUMINATION. ALCR MUST BE UL924 LISTED.
1/8" = 1'-0"
A1 FLOOR PLAN - AREA 'C' - LIGHTING
1" = 60'-0"
A5 KEY PLAN - AREA 'C'
GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
N
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
1 1
3 4
COMPATIBLE MATERIALS
THE MATERIALS SECTION OF U.L. 96A (SECTION 5) REQUIRES THAT METALS MUST
BE USED IN COMBINATIONS THAT ARE GALVANICALLY COMPATIBLE. THEREFORE,
ALUMINUM COMPONENTS MUST NOT BE INSTALLED IN DIRECT CONTACT WITH
BARE COPPER ROOFING MATERIALS/SURFACES, AND COPPER COMPONENTS
MUST NOT BE INSTALLED IN DIRECT CONTACT WITH BARE ALUMINUM ROOFING
MATERIALS/SURFACES. METALS ACCEPTABLE FOR USE WITH COPPER AND
ALUMINUM ARE AS FOLLOWS:
METALS ACCEPTABLE FOR USE WITH COPPER:
NICKEL, BRASS, TIN, LEAD, STAINLESS STEEL, AND MONEL.
METALS ACCEPTABLE FOR USE WITH ALUMINUM:
MAGNESIUM, ZINC, GALVANIZED STEEL, STAINLESS STEEL, LEAD, AND WROUGHT
IRON.
PAINT IS NOT CONSIDERED ACCETABLE BETWEEN GALVANICALLY INCOMPATIBLE
ROOFING, FLASHING, AND OTHER MATERIALS AND SURFACES.
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
SEE SHEET E-001 FOR GENERAL NOTES AND LEGEND.
JOB CONDITIONS MAY NECESSITATE SLIGHT VARIATION IN LOCATION OF
DOWN LEADS AND AIR TERMINALS.
INSTALLATION MUST BE IN ACCORDANCE WITH U.L. REQUIREMENTS AND
RECIEVE THE U.L. LIGHTNING PROTECTION INSPECTION CERTIFICATE.
INSTALLATION MUST BE PROVIDED BY A U.L. MASTER INSTALLER.
BOND ALL BODIES OF CONDUCTANCE AND BODIES OF INDUCTANCE
LOCATED WITHIN 6 FEET OF MAIN CONDUCTOR AS REQURIED.
CONDUCTOR MUST BE FASTENED A MAXIMUM OF 3 FEET ON CENTER.
ALL CONDUCTOR BENDS MUST BE A MINIMUM OF 90 DEGREES WITH A
MINIMUM 8 INCH RADIUS.
INSTALLATION TO BE PERFORMED IN A NEAT AND ORDERLY MANNER, AND
MUST BE DONE AS INCONSPICUOUSLY AS POSSIBLE.
VERIFY ELECTRICAL GROUND, WATER LINE, AND OTHER UNDERGROUND
PIPING IS COMMON WITH THE LIGHTNING PROTECTION GROUDNING.
A SURGE PROTECTIVE DEVICE OR UNIT MUST BE PROVIDED ON EACH
ELECTRICAL AND TELECOMMUNICATIONS SERVICE ENTRANCE, ALONG WITH
EACH RADIO AND TELEVISION LEAD-IN BY THE ELECTRICAL CONTRACTOR
OR RESPECTIVE SYSTEM INSTALLER.
ALL MATERIALS MUST BE U.L. LISTED.
INSTALLATION IS BASED UPON ALL ROOF-MOUNTED LIGHTNING
PROTECTION COMPONENTS BEING MECHANICALLY FASTENED TO ROOF
SURFACE. ANY VARIANCE OR SPECIAL PROVISIONS MUST BE
RESPONSIBILITY OF THE ROOFING OR GENERAL CONTRACTOR.
ALUMINUM MATERIALS MUST BE USED ON ALUMINUM SURFACES.
THE LIGHTNING PROTECTION SYSTEM IS DESIGNED AND DETAILED PER THE
CURRENT NFPA 780 AND U.L. 96A CODES. THE U.L. 96A MASTER LABEL
CERTIFICATION WILL BE ISSUED PRIOR TO BUILDING ACCEPTANCE.
CONTRACTOR MUST ENSURE THAT THE BASE PWD IS PRESENT FOR FINAL
TESTING OF GROUNDING SYSTEM.
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
AR
IN
E
CO
RP
S
NA
VA
L
ST
AT
IO
N
- N
OR
FO
LK
, V A
M
AR
IN
E
C O
R
PS
B
AS
E C
AM
P
LE
JE
U N
E, N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
M
ID
AT
LA
N
TI
C
AS INDICATED
Approved by Michael Foy, PE, Resident Engineer, MARSOC
/1
1/
:4 2:
P
M M
:\C am p Le je un e\ M
AR
SO
C S
O F
Ar m or y
(P -1
8)
\P
_E le ct ric al
_R
.rv t
R O
O F
PL
AN
LI
G H
TN
IN
G P
R O
TE
C
TI
O
N
E-110
1701821
P-
S
O F
AR
M
O R
Y
FINAL SUBMITTAL
12917092
10.08.2024
JTR MKW JTR
SL/RC
WRB
EJA
HPN
E-
1/16" = 1'-0"
A1 ROOF PLAN - LIGHTNING PROTECTION
PLAN NOTES
1 CLASS 1 AIR TERMINAL, 12 INCHES IN HEIGHT/LENGTH. USE 3/8 INCH
DIAMETER FOR COPPER OR 1/2 INCH DIAMETER FOR ALUMINUM. AIR
TERMINAL MATERIAL SHAL MATCH AND BE COMPATIBLE WITH MATERIAL
USED FOR CONDUCTORS. TYPICAL.
2 CLASS 1 CONDUCTORS MUST BE #17 AWG, 29 STRAND COPPER OR #14
AWG, 14 STRAND ALUMINUM. TYPICAL COPPER MUST BE USED
WHENEVER POSSIBLE.
3 DOWN LEAD CONDUCTOR CONNECTED TO GROUND LOOP. PROVIDE
PVC SCHEDULE 40 TO PROTECT CONDUCTOR FROM PHYSICAL DAMAGE.
CONNECT DOWN LEAD CONDUCTOR TO #3/0 AWG COPPER GROUND
LOOP AND USE 3/4 INCH BY 10 FOOT COPPERCLAD GROUND ROB BY
EXOTHERMIC CONNECTION. SEE GROUNDING DETAIL.
4 PROVIDE TEST WELL AT DOWNLEAD GROUND ROD LOCATION FOR
FUTURE TESTING AND MAINTENANCE.
5 #1/0 COUNTERPOISE GROUND LOOP.
GRAPHIC SCALE: 1/16"=1'-0"
16' 0 8' 16' 32' N
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
4 HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
HQ TE
AM
TE
AM
TE
AM
TE
AM
HQ
TE
AM
TE
AM
TE
AM
TE
AM
POWER NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ALL ELECTRICAL BOXES MOUNTED IN RATED WALLS MUST COMPLY WITH ALL
REQUIREMENTS OF THE IBC. UNLESS OTHERWISE NOTED, DEVICES SHOWN
IN RATED WALLS MUST BE FLUSH WITH CONDUIT CONCEALED. PROVIDE
HORIZONTAL SEPARATION, PUTTY PADS, RATED BOXES ETC. AS REQUIRED
FOR REQUIRED INSTALLATION.
SEE VOLTAGE…