Attachment 8-Part 7 of 9-Drawings-EHRM-Salt Lake City.pdf
PDF 18 MB Posted
- Solicitation number
- 36C77623B0041
About this file
This document provides details for a federal contract opportunity for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting proposals under solicitation number 36C77623B0041 for infrastructure upgrades at the Salt Lake City VAMC. Offerors should provide construction services to upgrade EHRM infrastructure at Project 660-21-700. The attached file is a set of drawings with specifications for the project. Proposals are due by the date listed in the solicitation document. The agency intends to award a firm-fixed-price contract to the responsible offeror with the lowest priced, technically acceptable proposal.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CG CG
CG
CG
CG
CG
CG
CG
CGCG
CGCG
CG
CGCG
CG CG
CG CG
CGCG
CG
CG
CG
CG
UP
D O W N
DOWN
2C00
2B05
2BA
2A19B
2D00
2D00A
2D00B
2D00C
2D00D
2CAA
2CA
2D32D
2D26
2D24
2D22
2D20
2D18A
2D18
2D16 2D14
2D14A
2D12
2D10
2DO8
2DO6
2D02
2DO4
2D01
2D03
2D07A
2D07
2D09
2DB
2D11
2D13
2D15A
2D15
2D17
2D19
2D21
2D21A
2D23A
2D23
2D25
2D27
2D28
2D30
2DA
2D31
2D29
2D34 2D32F
2D32E
2D32C
2D32B 2D32A
2D32
2C42
2C42A
2C40A
2C38
2C36
2C34A
2C34
2C43
2C41 2C39
2C33
2C31
2C29
2C27
2C25
2C23
2C21
2C192C17
2C15
2C13
2C11
2C09
2C07
2C05A
2C05
2C30
2C26
2C28
2C24
2C22
2C20A 2C20B
2C20
2C18A 2C18B
2C18
2C16
2C14
2C12
2C10
2C10A
2D05
2C08
2C32
2C35
2C00
2B03C
2B00
2BE2
2B07
2B01
2BO3B2B03A
2B08
2B02
2BE1
2B
A
2B04A
2BAA
2A20
2A22
2A
A
2A08
2A
B
2A10
2A12
2A00
2A09 2A03
2A05
2A13
2A11
2A17
2A19A
2A23
2A25
2A00AA
2A29
2A36 2A32
2A28
2A30
2A14
2AAA
2AA
2A18
2A02A 2C37
2C40
2C03 2C01
2A06A
2C06
2C04
2C02
2B03D
2B09
2B03
2B08A
2B06
2BO4
2A01
2A15
2A21
2A07
2A02
2A19
2A06
2A04
2A26
2A24
2A14A
2A27
2A27A
2A34
2A31
2A38
2A33 2A07A
2A16
CORRIDOR
CONFERENCE ROOM (151)
OFFICE, PSYCH
CORRIDOR (TO D-ZONE,EAST)
CORRIDOR (TO LABS)
CORRIDOR (LABS)
CORRIDOR (TO LABS)
(TO D-ZONE,NORTH)
ROOF ACCESS
STAIR
OFFICE
OFFICE (151)
OFFICE
OFFICE
SHOWER
/DRESS (151)
MEN
HAC WOMEN
DRESS (151)
FREZER
OFFICE
OFFICE
ICE
BREAK RM.
STORAGE
LAB
OFFICE
LAB
LAB 1
STO.
STAIR
ELEC.
DATA
OFFICE
LAB 2
LAB 3
LAB 4
LAB 5
OFFICE
TISSUE CULTURE
LAB 6
LAB 7
FREZER
BREAK RM.
CONFERENCE
STAIRS
ELEC.
DATA
STO.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICES
LAB
TC
TC
EXAM
TOILET
EXAM
LAB/FREZER
LAB
LAB/FREZER
STO.
ELEC.
OFFICE
CONFERENCE
OFFICE
OFFICE
OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
EXAM
OFFICE
BREAK
MECH.
MEN
WOMEN
OFFICE
OFFICE OFFICE
MEETING
OFFICE
OFFICE
MEETING
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STO.
STO.
CORRIDOR
OFFICE ( )
CORRIDOR
ELEVATORKITCHEN
OFFICE ( )OFFICE ( )
STORAGE (151)
FIRE EQUIPMENT
ELEVATOR
LO
B
B Y
(E
LE
V A
T O
R
TOILET (UNISEX)
STAIR (TO ROOF)
ELECTRICAL
OFFICE (151)
C O
R R
ID
O
R
REFRIGERATOR (WALK-IN)
C O
R R
ID
O
R
LAB.OFFICE (151)
LAB/OFFICE (151)
CORRIDOR
LAB (151)
OFFICE (151)
BREAK ROOM
LAB (151)
DARKROOM
LAB (151)
OFFICE (151)
STORAGE (SUPPLY)
TOILET (UNISEX)
MECH (PIPE CHASE)
REFRIGERATOR (WALK-IN)
LAB (151) OFFICE (151)
FIRE EQUIPMENT
LAB (151)
OFFICE (151)
ROOF ACCESS
STAIR
REFRIGERATOR (WALK-IN)
STORAGE COMP LAB
LAB
OFFICES (182,7-WRKSTNS)
CONFERENCE (151)
(UNISEX)
OFFICE
(EDUCATION MNGR)
OFFICE (ED-05)
OFFICE
OFFICE
SHOP, ELEC.
TOILET (UNISEX)
RECEPTION
OFFICE
STAIR
LAB
OFFICE (151)
LAB
LAB
FREEZER
CONFERENCE ROOM
TEL/DATA
FIRE EQUIPMENT
STORAGE (SUPPLY)
AUX.SYS
STORAGE
GLASS WARE WASHING LAB
STORAGE
LAB
LAB
LAB
LAB
OFFICE
TOILET
CORRIDOR
SHOWER/
SHOWER/
(UNISEX)
TOILET
(REFRIGERATOR)
EQUIPMENT
CORRIDOR
CORRIDOR
T
T
T
T
T
02-ED403
F6
02-ED402
D2
02-ED403
D5
02-ED402
F2
02-ED403
D7
EXISTING TR LOCATION TO BE MOVED
EXISTING TR TO REMAIN
NEW TR LOCATION
SEPARATION LINE INDICATES
TERMINATION OF DATA CABLES TO
SPECIFIED TR LOCATION
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:1
A
M
02-ED120
OVERALL SECOND FLOOR
ELECTRICAL DEMOLITION PLAN
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
NORTH
1/16" = 1'-0"F1
OVERALL SECOND FLOOR ELECTRICAL DEMOLITION PLAN
1 UNLESS NOTED OTHERWISE REMOVE ALL LIGHTING
FIXTURES DEVICES AND EQUIPMENT SHOWN DASHED.
REMOVE CONDUIT AND WIRING BACK TO PANELBOARD
OF ORIGIN OR TO FIRST ACTIVE DEVICE THAT
REMAINS.
2 SALVAGE ALL LIGHT FIXTURES, TWIST-LOCK
RECEPTACLES AND WALLPLATES, CEILING SPEAKERS
AND SECURITY AND FIRE ALARM DEVICES TO OWNER.
PROTECT SALVAGED EQUIPMENT FROM DAMAGE.
3 PRIOR TO SUBMITTING BID, VISIT THE SITE AND FIELD
VERIFY THE EXTENT OF ELECTRICAL AND DATA
DEMOLITION WORK TO MEET THE INTENT OF THE BID
DOCUMENTS AND INCLUDE ALL COSTS IN BID.
4 PRIOR TO REMOVAL OF ANY ELECTRICAL EQUIPMENT
OR WIRING, FIELD VERIFY THAT THE EQUIPMENT OR
WIRING IS INACTIVE OR NO LONGER IN USE.
5 REMOVE ALL DEVICES, RACEWAYS AND WIRING FROM
WALLS TO BE REMOVED. WHERE ACTIVE RACEWAYS
OCCUR IN WALLS TO BE REMOVED, RE-ROUTE THE
RACEWAY WITH ASSOCIATED WIRING TO KEEP THE
CIRCUIT OPERATIONAL.
6 REMOVE ALL FIRE ALARM DEVICES WHERE EXISTING
WALLS AND CEILINGS ARE BEING REMOVED, WITH
ASSOCIATED CONDUIT AND WIRING. EXISTING FIRE
ALARM DEVICES AND SYSTEM NOT INDICATED FOR
REMOVAL SHALL REMAIN ACTIVE THROUGHOUT
DEMOLITION AND CONSTRUCTION UNTIL THE NEW
SYSTEM IS TESTED AND OPERATIONAL. MAINTAIN ALL
CLASS A FIRE ALARM INITIATING AND INDICATING
LOOPS WHERE EXISTING DEVICES ARE REMOVED.
7 REMOVE ALL ABANDONED RACEWAY, CONDUIT,
WIRING AND CABLING WHETHER ABANDONED
PREVIOUS TO THIS PROJECT OR AS A RESULT OF THIS
PROJECT. NOT ALL ABANDONED ITEMS ARE SHOWN
ON THESE PLANS AND FIELD VERIFICATION OF
DEMOLITION SCOPE EXTENT IS REQUIRED.
8 DEVICES MARKED "RR" ARE TO BE REMOVED AND
RELOCATED PER NEW PLANS. EXTEND CIRCUITING AS
REQUIRED FOR RELOCATION.
9 REFER TO ARCHITECTURAL DRAWINGS FOR REMOVAL
OF MOTORS, CONDUIT, CONDUCTOR AND CONTROL
WIRING ASSOCIATED WITH EXISTING MOTORIZED
DOORS, PARTITIONS AND LIGHTING.
10 DEMOLISH ALL OIT WI-FI ACCESS POINTS WHETHER
SHOWN ON DRAWINGS OR NOT WITHIN SCOPE OF
WORK AREA. DO NOT REMOVE THE BIO-MED PUBLIC
WI-FI ACCESS POINTS.
11 REMOVE FEEDERS FOR ALL DEMOLISHED PANELS,
DISCONNETS, ETC. BACK TO SOURCE
12 ALL ITEMS INDICATED TO REMAIN SHALL BE
PROTECTED DURING ALL PHASES OF CONSTRUCTION.
13 CONTRACTOR TO TRACE AND LABEL ALL EXISTING
LOADS TO REMAIN, THAT ARE CURRENTLY FED FROM
PANELS THAT ARE BEING DEMOLISHED IN THIS PHASE.
THESE LOADS TO BE RE-FED FROM NEW PANELS IN
NEXT PHASE.
14 ALL HVAC UNITS TO BE REMOVED BY MECHANICAL
CONTRACTOR UNLESS NOTED OTHERWISE. REMOVE
ALL ASSOCIATED RACEWAYS AND CONDUCTORS BACK
TO SOURCE.
15 REPLACE DATA DEVICES IN HEADWALLS OF EXISTING
DATA LOCATIONS.
16 ALL DATA DEVICES SHOWN TO BE DEMOLISHED AS
PART OF THIS PROJECT SHALL HAVE RACEWAYS
REMOVED AS PART OF THE DEMOLITION SCOPE OF
WORK. DEMOLISHED DATA DEVICES ARE INDENTIFIED
AS DASHED DEVICES AND KEYNOTED.
17 ALL DATA DEVICES SHOWN ARE TO BE REPLACED
UNLESS OTHERWISE SPECIFIED ON THE FLOOR PLANS.
ALL EXISTING DATA DEVICE PATHWAYS SHALL REMAIN
INTACT AND BE REUSED FOR NEW CABLE
INSTALLATION.
18 REMOVE ALL EXISTING CABLES THAT ARE TO BE
REPLACED BACK TO THE PATCH PANEL.
19 REMOVE ANY WALL MOUNT RACKS, OR FLOOR MOUNT
RACKS ONCE THEY ARE EMPTY AND HAVE NO
ADDITIONAL CABLES OR EQUIPMENT IN THEM.
20 REMOVE EXISTING FIBER FROM TR BACK TO THE MCR
AND ALL FIBER TERMINATION EQUIPMENT AFTER ALL
NETWORK SERVICES HAVE BEEN REMOVED.
21 ALL BIOMED EQUIPMENT TO REMAIN. PRESERVE AND
PROTECT DURING THE STRUCTURED CABLING
UPGRADE.
GENERAL
SHEET NOTES
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
SHEET
KEYNOTES
TR LEGEND
SPECIAL PROJECT
NOTES
1. DRAWINGS MAY NOT SHOW OR INDICATE ALL DATA
LOCATION THAT MAY BE REMOVED AS PART OF
THIS PROJECT. CONTRACTOR TO VERIFY ALL
CABLES TO BE DEMOLISHED COMPLETELY TO THE
VA PATCH PANEL.
Revisions: Date:
06/08/23
T
1A36
TEL/DATA
OFFICE (182-SOC WKR)
T
GA28
TEL/DATA (142)
T
GC19
GC21
ELECTRICAL
TEL/DATA
STAIR/VESTIBULE
T
GD03
GD05
ELECTRICAL
TEL/DATAT
GC02A
TELEPHONE EQUIPMENT
ENTRY (TELEPHONE EQUIPMT/STORAGE)
T
"2-G-C-C-P1"
"2-G-C-E-P1"
"2EGC1"
"2CGC1"
"2-G-D-E-P3"
"2EDG1"
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:2
A
M
02-ED401
ENLARGED DEMOLITION PLANS EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
1 UNLESS NOTED OTHERWISE REMOVE ALL LIGHTING
FIXTURES DEVICES AND EQUIPMENT SHOWN DASHED.
REMOVE CONDUIT AND WIRING BACK TO PANELBOARD
OF ORIGIN OR TO FIRST ACTIVE DEVICE THAT
REMAINS.
2 SALVAGE ALL LIGHT FIXTURES, TWIST-LOCK
RECEPTACLES AND WALLPLATES, CEILING SPEAKERS
AND SECURITY AND FIRE ALARM DEVICES TO OWNER.
PROTECT SALVAGED EQUIPMENT FROM DAMAGE.
3 PRIOR TO SUBMITTING BID, VISIT THE SITE AND FIELD
VERIFY THE EXTENT OF ELECTRICAL AND DATA
DEMOLITION WORK TO MEET THE INTENT OF THE BID
DOCUMENTS AND INCLUDE ALL COSTS IN BID.
4 PRIOR TO REMOVAL OF ANY ELECTRICAL EQUIPMENT
OR WIRING, FIELD VERIFY THAT THE EQUIPMENT OR
WIRING IS INACTIVE OR NO LONGER IN USE.
5 REMOVE ALL DEVICES, RACEWAYS AND WIRING FROM
WALLS TO BE REMOVED. WHERE ACTIVE RACEWAYS
OCCUR IN WALLS TO BE REMOVED, RE-ROUTE THE
RACEWAY WITH ASSOCIATED WIRING TO KEEP THE
CIRCUIT OPERATIONAL.
6 REMOVE ALL FIRE ALARM DEVICES WHERE EXISTING
WALLS AND CEILINGS ARE BEING REMOVED, WITH
ASSOCIATED CONDUIT AND WIRING. EXISTING FIRE
ALARM DEVICES AND SYSTEM NOT INDICATED FOR
REMOVAL SHALL REMAIN ACTIVE THROUGHOUT
DEMOLITION AND CONSTRUCTION UNTIL THE NEW
SYSTEM IS TESTED AND OPERATIONAL. MAINTAIN ALL
CLASS A FIRE ALARM INITIATING AND INDICATING
LOOPS WHERE EXISTING DEVICES ARE REMOVED.
7 REMOVE ALL ABANDONED RACEWAY, CONDUIT,
WIRING AND CABLING WHETHER ABANDONED
PREVIOUS TO THIS PROJECT OR AS A RESULT OF THIS
PROJECT. NOT ALL ABANDONED ITEMS ARE SHOWN
ON THESE PLANS AND FIELD VERIFICATION OF
DEMOLITION SCOPE EXTENT IS REQUIRED.
8 DEVICES MARKED "RR" ARE TO BE REMOVED AND
RELOCATED PER NEW PLANS. EXTEND CIRCUITING AS
REQUIRED FOR RELOCATION.
9 REFER TO ARCHITECTURAL DRAWINGS FOR REMOVAL
OF MOTORS, CONDUIT, CONDUCTOR AND CONTROL
WIRING ASSOCIATED WITH EXISTING MOTORIZED
DOORS, PARTITIONS AND LIGHTING.
10 DEMOLISH ALL OIT WI-FI ACCESS POINTS WHETHER
SHOWN ON DRAWINGS OR NOT WITHIN SCOPE OF
WORK AREA. DO NOT REMOVE THE BIO-MED PUBLIC
WI-FI ACCESS POINTS.
11 REMOVE FEEDERS FOR ALL DEMOLISHED PANELS,
DISCONNETS, ETC. BACK TO SOURCE
12 ALL ITEMS INDICATED TO REMAIN SHALL BE
PROTECTED DURING ALL PHASES OF CONSTRUCTION.
13 CONTRACTOR TO TRACE AND LABEL ALL EXISTING
LOADS TO REMAIN, THAT ARE CURRENTLY FED FROM
PANELS THAT ARE BEING DEMOLISHED IN THIS PHASE.
THESE LOADS TO BE RE-FED FROM NEW PANELS IN
NEXT PHASE.
14 ALL HVAC UNITS TO BE REMOVED BY MECHANICAL
CONTRACTOR UNLESS NOTED OTHERWISE. REMOVE
ALL ASSOCIATED RACEWAYS AND CONDUCTORS BACK
TO SOURCE.
15 REPLACE DATA DEVICES IN HEADWALLS OF EXISTING
DATA LOCATIONS.
16 ALL DATA DEVICES SHOWN TO BE DEMOLISHED AS
PART OF THIS PROJECT SHALL HAVE RACEWAYS
REMOVED AS PART OF THE DEMOLITION SCOPE OF
WORK. DEMOLISHED DATA DEVICES ARE INDENTIFIED
AS DASHED DEVICES AND KEYNOTED.
17 ALL DATA DEVICES SHOWN ARE TO BE REPLACED
UNLESS OTHERWISE SPECIFIED ON THE FLOOR PLANS.
ALL EXISTING DATA DEVICE PATHWAYS SHALL REMAIN
INTACT AND BE REUSED FOR NEW CABLE
INSTALLATION.
18 REMOVE ALL EXISTING CABLES THAT ARE TO BE
REPLACED BACK TO THE PATCH PANEL.
19 REMOVE ANY WALL MOUNT RACKS, OR FLOOR MOUNT
RACKS ONCE THEY ARE EMPTY AND HAVE NO
ADDITIONAL CABLES OR EQUIPMENT IN THEM.
20 REMOVE EXISTING FIBER FROM TR BACK TO THE MCR
AND ALL FIBER TERMINATION EQUIPMENT AFTER ALL
NETWORK SERVICES HAVE BEEN REMOVED.
21 ALL BIOMED EQUIPMENT TO REMAIN. PRESERVE AND
PROTECT DURING THE STRUCTURED CABLING
UPGRADE.
GENERAL
SHEET NOTES
NORTH
1/2" = 1'-0"F8
ENLARGED EXISITNG TEL/DATA
GB03-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"F3
ENLARGED EXISTING TR 1A36-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"D6
ENLARGED
EXISTING TEL/DATA GA28-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"D8
ENLARGED
EXISTING TEL/DATA GC21-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"D3
ENLARGED EXISTING TEL/DATA GD05-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"B3
ENLARGED EXISTING TELEPHONE EQUIIPMENT GC02A-2 DEMOLITION PLAN
0' 1' 2' 4' 8'
GRAPHIC SCALE 1/2" = 1'-0"
1D37
1D35
UTILITY ROOM
AUX.SYS
T
1B09
1B07
ELECTRCAL
ELECTRICAL
T
1C31
TELE/DATA (142)
CG
T
1D07
1D09
ELECTRICAL
TEL/DATA
T
CG
2C33
2C31
STO.
ELEC.
T
2D13
DATA
T
"2-1-D-C-P5" "2-1-D-C-P6"
"2NRD2""2E1D4"
"2-1-B-E-P1"
"2-1-B-C-P1"
"2E1B1"
"2C1B1"
"2-1-D-C-P2"
"2-1-D-C-P1"
"2NRD1"
"2E1D1"
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:3
A
M
02-ED402
ENLARGED DEMOLITION PLANS EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
1 UNLESS NOTED OTHERWISE REMOVE ALL LIGHTING
FIXTURES DEVICES AND EQUIPMENT SHOWN DASHED.
REMOVE CONDUIT AND WIRING BACK TO PANELBOARD
OF ORIGIN OR TO FIRST ACTIVE DEVICE THAT
REMAINS.
2 SALVAGE ALL LIGHT FIXTURES, TWIST-LOCK
RECEPTACLES AND WALLPLATES, CEILING SPEAKERS
AND SECURITY AND FIRE ALARM DEVICES TO OWNER.
PROTECT SALVAGED EQUIPMENT FROM DAMAGE.
3 PRIOR TO SUBMITTING BID, VISIT THE SITE AND FIELD
VERIFY THE EXTENT OF ELECTRICAL AND DATA
DEMOLITION WORK TO MEET THE INTENT OF THE BID
DOCUMENTS AND INCLUDE ALL COSTS IN BID.
4 PRIOR TO REMOVAL OF ANY ELECTRICAL EQUIPMENT
OR WIRING, FIELD VERIFY THAT THE EQUIPMENT OR
WIRING IS INACTIVE OR NO LONGER IN USE.
5 REMOVE ALL DEVICES, RACEWAYS AND WIRING FROM
WALLS TO BE REMOVED. WHERE ACTIVE RACEWAYS
OCCUR IN WALLS TO BE REMOVED, RE-ROUTE THE
RACEWAY WITH ASSOCIATED WIRING TO KEEP THE
CIRCUIT OPERATIONAL.
6 REMOVE ALL FIRE ALARM DEVICES WHERE EXISTING
WALLS AND CEILINGS ARE BEING REMOVED, WITH
ASSOCIATED CONDUIT AND WIRING. EXISTING FIRE
ALARM DEVICES AND SYSTEM NOT INDICATED FOR
REMOVAL SHALL REMAIN ACTIVE THROUGHOUT
DEMOLITION AND CONSTRUCTION UNTIL THE NEW
SYSTEM IS TESTED AND OPERATIONAL. MAINTAIN ALL
CLASS A FIRE ALARM INITIATING AND INDICATING
LOOPS WHERE EXISTING DEVICES ARE REMOVED.
7 REMOVE ALL ABANDONED RACEWAY, CONDUIT,
WIRING AND CABLING WHETHER ABANDONED
PREVIOUS TO THIS PROJECT OR AS A RESULT OF THIS
PROJECT. NOT ALL ABANDONED ITEMS ARE SHOWN
ON THESE PLANS AND FIELD VERIFICATION OF
DEMOLITION SCOPE EXTENT IS REQUIRED.
8 DEVICES MARKED "RR" ARE TO BE REMOVED AND
RELOCATED PER NEW PLANS. EXTEND CIRCUITING AS
REQUIRED FOR RELOCATION.
9 REFER TO ARCHITECTURAL DRAWINGS FOR REMOVAL
OF MOTORS, CONDUIT, CONDUCTOR AND CONTROL
WIRING ASSOCIATED WITH EXISTING MOTORIZED
DOORS, PARTITIONS AND LIGHTING.
10 DEMOLISH ALL OIT WI-FI ACCESS POINTS WHETHER
SHOWN ON DRAWINGS OR NOT WITHIN SCOPE OF
WORK AREA. DO NOT REMOVE THE BIO-MED PUBLIC
WI-FI ACCESS POINTS.
11 REMOVE FEEDERS FOR ALL DEMOLISHED PANELS,
DISCONNETS, ETC. BACK TO SOURCE
12 ALL ITEMS INDICATED TO REMAIN SHALL BE
PROTECTED DURING ALL PHASES OF CONSTRUCTION.
13 CONTRACTOR TO TRACE AND LABEL ALL EXISTING
LOADS TO REMAIN, THAT ARE CURRENTLY FED FROM
PANELS THAT ARE BEING DEMOLISHED IN THIS PHASE.
THESE LOADS TO BE RE-FED FROM NEW PANELS IN
NEXT PHASE.
14 ALL HVAC UNITS TO BE REMOVED BY MECHANICAL
CONTRACTOR UNLESS NOTED OTHERWISE. REMOVE
ALL ASSOCIATED RACEWAYS AND CONDUCTORS BACK
TO SOURCE.
15 REPLACE DATA DEVICES IN HEADWALLS OF EXISTING
DATA LOCATIONS.
16 ALL DATA DEVICES SHOWN TO BE DEMOLISHED AS
PART OF THIS PROJECT SHALL HAVE RACEWAYS
REMOVED AS PART OF THE DEMOLITION SCOPE OF
WORK. DEMOLISHED DATA DEVICES ARE INDENTIFIED
AS DASHED DEVICES AND KEYNOTED.
17 ALL DATA DEVICES SHOWN ARE TO BE REPLACED
UNLESS OTHERWISE SPECIFIED ON THE FLOOR PLANS.
ALL EXISTING DATA DEVICE PATHWAYS SHALL REMAIN
INTACT AND BE REUSED FOR NEW CABLE
INSTALLATION.
18 REMOVE ALL EXISTING CABLES THAT ARE TO BE
REPLACED BACK TO THE PATCH PANEL.
19 REMOVE ANY WALL MOUNT RACKS, OR FLOOR MOUNT
RACKS ONCE THEY ARE EMPTY AND HAVE NO
ADDITIONAL CABLES OR EQUIPMENT IN THEM.
20 REMOVE EXISTING FIBER FROM TR BACK TO THE MCR
AND ALL FIBER TERMINATION EQUIPMENT AFTER ALL
NETWORK SERVICES HAVE BEEN REMOVED.
21 ALL BIOMED EQUIPMENT TO REMAIN. PRESERVE AND
PROTECT DURING THE STRUCTURED CABLING
UPGRADE.
GENERAL
SHEET NOTES
NORTH
1/2" = 1'-0"F7
ENLARGED EXISTING AUX SYS 1D35-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"D7
ENLARGED EXISTING TEL/DATA 1B09-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"F4
ENLARGED EXISTING TEL/DATA 1C14-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"D4
ENLARGED EXISTING TEL/DATA 1D09-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"F2
ENLARGED EXISTING DATA 2C33-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"D2
ENLARGED EXISTING DATA 2D13-2 DEMOLITION PLAN
0' 1' 2' 4' 8'
GRAPHIC SCALE 1/2" = 1'-0"
2A24
TEL/DATA
T
2D31
2D29
ELEC.
DATA
T
2B05
2B07
TEL/DATA
SHOP, ELEC.
T
"2-2-B-C-P1"
"2-2-B-E-P1"
"2C2B1"
"2E2B1"
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:4
A
M
02-ED403
ENLARGED DEMOLITION PLANS EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
NORTH
1/2" = 1'-0"F6
ENLARGED EXISTING TR 2A24-2 DEMOLITION PLAN
1 UNLESS NOTED OTHERWISE REMOVE ALL LIGHTING
FIXTURES DEVICES AND EQUIPMENT SHOWN DASHED.
REMOVE CONDUIT AND WIRING BACK TO PANELBOARD
OF ORIGIN OR TO FIRST ACTIVE DEVICE THAT
REMAINS.
2 SALVAGE ALL LIGHT FIXTURES, TWIST-LOCK
RECEPTACLES AND WALLPLATES, CEILING SPEAKERS
AND SECURITY AND FIRE ALARM DEVICES TO OWNER.
PROTECT SALVAGED EQUIPMENT FROM DAMAGE.
3 PRIOR TO SUBMITTING BID, VISIT THE SITE AND FIELD
VERIFY THE EXTENT OF ELECTRICAL AND DATA
DEMOLITION WORK TO MEET THE INTENT OF THE BID
DOCUMENTS AND INCLUDE ALL COSTS IN BID.
4 PRIOR TO REMOVAL OF ANY ELECTRICAL EQUIPMENT
OR WIRING, FIELD VERIFY THAT THE EQUIPMENT OR
WIRING IS INACTIVE OR NO LONGER IN USE.
5 REMOVE ALL DEVICES, RACEWAYS AND WIRING FROM
WALLS TO BE REMOVED. WHERE ACTIVE RACEWAYS
OCCUR IN WALLS TO BE REMOVED, RE-ROUTE THE
RACEWAY WITH ASSOCIATED WIRING TO KEEP THE
CIRCUIT OPERATIONAL.
6 REMOVE ALL FIRE ALARM DEVICES WHERE EXISTING
WALLS AND CEILINGS ARE BEING REMOVED, WITH
ASSOCIATED CONDUIT AND WIRING. EXISTING FIRE
ALARM DEVICES AND SYSTEM NOT INDICATED FOR
REMOVAL SHALL REMAIN ACTIVE THROUGHOUT
DEMOLITION AND CONSTRUCTION UNTIL THE NEW
SYSTEM IS TESTED AND OPERATIONAL. MAINTAIN ALL
CLASS A FIRE ALARM INITIATING AND INDICATING
LOOPS WHERE EXISTING DEVICES ARE REMOVED.
7 REMOVE ALL ABANDONED RACEWAY, CONDUIT,
WIRING AND CABLING WHETHER ABANDONED
PREVIOUS TO THIS PROJECT OR AS A RESULT OF THIS
PROJECT. NOT ALL ABANDONED ITEMS ARE SHOWN
ON THESE PLANS AND FIELD VERIFICATION OF
DEMOLITION SCOPE EXTENT IS REQUIRED.
8 DEVICES MARKED "RR" ARE TO BE REMOVED AND
RELOCATED PER NEW PLANS. EXTEND CIRCUITING AS
REQUIRED FOR RELOCATION.
9 REFER TO ARCHITECTURAL DRAWINGS FOR REMOVAL
OF MOTORS, CONDUIT, CONDUCTOR AND CONTROL
WIRING ASSOCIATED WITH EXISTING MOTORIZED
DOORS, PARTITIONS AND LIGHTING.
10 DEMOLISH ALL OIT WI-FI ACCESS POINTS WHETHER
SHOWN ON DRAWINGS OR NOT WITHIN SCOPE OF
WORK AREA. DO NOT REMOVE THE BIO-MED PUBLIC
WI-FI ACCESS POINTS.
11 REMOVE FEEDERS FOR ALL DEMOLISHED PANELS,
DISCONNETS, ETC. BACK TO SOURCE
12 ALL ITEMS INDICATED TO REMAIN SHALL BE
PROTECTED DURING ALL PHASES OF CONSTRUCTION.
13 CONTRACTOR TO TRACE AND LABEL ALL EXISTING
LOADS TO REMAIN, THAT ARE CURRENTLY FED FROM
PANELS THAT ARE BEING DEMOLISHED IN THIS PHASE.
THESE LOADS TO BE RE-FED FROM NEW PANELS IN
NEXT PHASE.
14 ALL HVAC UNITS TO BE REMOVED BY MECHANICAL
CONTRACTOR UNLESS NOTED OTHERWISE. REMOVE
ALL ASSOCIATED RACEWAYS AND CONDUCTORS BACK
TO SOURCE.
15 REPLACE DATA DEVICES IN HEADWALLS OF EXISTING
DATA LOCATIONS.
16 ALL DATA DEVICES SHOWN TO BE DEMOLISHED AS
PART OF THIS PROJECT SHALL HAVE RACEWAYS
REMOVED AS PART OF THE DEMOLITION SCOPE OF
WORK. DEMOLISHED DATA DEVICES ARE INDENTIFIED
AS DASHED DEVICES AND KEYNOTED.
17 ALL DATA DEVICES SHOWN ARE TO BE REPLACED
UNLESS OTHERWISE SPECIFIED ON THE FLOOR PLANS.
ALL EXISTING DATA DEVICE PATHWAYS SHALL REMAIN
INTACT AND BE REUSED FOR NEW CABLE
INSTALLATION.
18 REMOVE ALL EXISTING CABLES THAT ARE TO BE
REPLACED BACK TO THE PATCH PANEL.
19 REMOVE ANY WALL MOUNT RACKS, OR FLOOR MOUNT
RACKS ONCE THEY ARE EMPTY AND HAVE NO
ADDITIONAL CABLES OR EQUIPMENT IN THEM.
20 REMOVE EXISTING FIBER FROM TR BACK TO THE MCR
AND ALL FIBER TERMINATION EQUIPMENT AFTER ALL
NETWORK SERVICES HAVE BEEN REMOVED.
21 ALL BIOMED EQUIPMENT TO REMAIN. PRESERVE AND
PROTECT DURING THE STRUCTURED CABLING
UPGRADE.
GENERAL
SHEET NOTES
NORTH
1/2" = 1'-0"D7
ENLARGED EXISTING DATA 2D29-2 DEMOLITION PLAN
NORTH
1/2" = 1'-0"D5
ENLARGED EXISTING TEL/DATA 2B07-2 DEMOLITION PLAN
UP
DN
DN
GA251
GC00C
GB00BA
GD09C
GD09B
GD09D
GCAA
GC13
GC15
GC17
GC13A
GC11A
GC11
GC09
GC07
GC07A
GC45
GC05
GDB
GA28A
GB03
GC22
GD01A
GD01
GD00
GD03
GD05
GD09A
GD07
GD02
GD00A
GD00B
GD11
GD04
GDA
GD13
GC02A
GC03
GC00A
GC01
GC06
GC04
GC04A
GC02B
GC02
GC10
GC12
GC14 GC16
GC18
GC20
GC27A
GC27
GC27B
GC00
GC29
GC19
GC21
GCA
GC23
GC25
GB00AA
GB09
GB09C
GBE2
GB09B
GB09AG
B
B
GB05
GB01
GB05A
GBA
G B
A
GBE1
GA06
G A
A
GA01GA03
GA05
GA07
GA09
GA38
GA02
GA04A
GA04
GA18
GA16
GA14
GA12
G A
B
GA10
GA00C
GA20
GA19B
GA15
GA26
GAA
GAAA
GA28
GA30
GA34A
GA32
GA34GA36
GA25B
GA25A
GA25I
GA25H
GA25G
GA25F
GA25E
GA25D
GC08
GB07
GA04B
GA22
GA24
GA00
GA07AGA15A
GA11
GA13
GA08
GA25
GA19
GA17
GA25C
GA19A
GA23
GA21
GA21A
GD09
CORRIDOR (TO LABS)
VESTIBULE
MECHANICAL SHAFT (138)
MECHANICAL SHAFT (138)
MECHANICAL SHAFT (138)
VESTIBULE
LAB
LAB
FREEZERS
BREAK ROOM
LAB (151)
LAB
LAB
LAB
LAB
SHAFT
HW STORAGE
STAIR
MECH (138)
TEL/DATA
(PIPE CHASE)
MECHANICAL
MECHANICAL
CORRIDOR
ELECTRICAL
TEL/DATA
ACCESS (138)
MECHANICAL
STORAGE (151)
HALLWAY (TO MECH)
HALLWAY (TO MECH)
AUX.SYS
MECHANICAL
STAIR
ELECTRICAL
TELEPHONE EQUIPMENT
MECHANICAL
CORRIDOR (TO DOCK)
MECHANICAL
COLD ROOM
STORAGE (151)
STORAGE (151)
STORAGE (151)
ENTRY (TELEPHONE EQUIPMT/STORAGE)
DARK ROOM
COLD ROOM
LAB (151) LAB (151)
LAB (151)
LAB (151)
OFFICE (151)
LAB (151)
LAB (151)
CORRIDOR
LAB (151)
ELECTRICAL
TEL/DATA
STAIR/VESTIBULE
HAC
FIRE EQUIPMENT
FIRE EQUIPMENT
DOCK (RECEIVING)
MECH (WATER SYS)
ELEVATOR
LINEN (CLEAN)
HAC
C O
R R
ID
O
R
TO
D
O C
K
ELECTRICAL
ELECTRICAL
ELECTRICAL
STAIR
LO
B
B Y
(E
LE
V A
T O
R
) ELEVATOR
COLD ROOM (151)
C O
R R
ID
O
R
T O
R E
S T
R O
O M
S
(PIPE TUNNEL)STORAGE (151)
STORAGE (151)
ENTRY (TOILET)
OFFICE
MECH (138)
STORAGE (151)
LAB
LAB
LAB (ENDO)
LAB (ENDO)
LAB (ENDO)
LAB (ENDO)
C O
R R
ID
O
R
LAB (ENDO)
MECH (REFRIGERATOR)
LAB (ENDO)
OFFICE
ENTRY (TOILET)
ELECTRICAL (138)
STAIR
(PIPE CHASE)
TEL/DATA (142)
AUX.SYS (138)
MECH (PIPE CHASE)
FIRE EQUIPMENT
STORAGELAB (151)
LAB (151)
STORAGE (151)
OFFICE
STORAGE (151)
STORAGE (151)
COMPUTER ROOM (151)
OFFICE
RECEPTION
MECHANICAL (COLD RM)
LINEN (SOILED)
OFFICE
LAB (ENDO)
LAB (ENDO)
CORRIDOR
TOILET (WOMEN)TOLIET, MEN
MECH (PIPE TUNNEL)
OFFICE
FIRE EQUIPMENT
ENTRY (NEURO/PSYCH RES)
ENTRY (NEUROLOGY)
STORAGE (151)
OFFICE (151)
LOUNGE
OFFICE (151)
CONFERENCE RM (151)
OFFICE (151)
MECH
PIPE TUNNEL
MECH
MECH
MECHANICAL ROOM (138)
CORRIDOR
TT
T
T
T
T
H
H
A WING
B WING
D WING
C WING
02-EP401
F7
02-EP402
F8
02-EP402
E8
02-EP402
D8
02-EP402
B8
Room
TELECOMMUNICATIONS
/ ENTRY
ROOM
GC02A-02
"2-G-B-C-D1"
"2-G-B-E-D1"
"2CMP2B"
"2DPE"
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:5
A
M
02-EP100
OVERALL GROUND FLOOR
POWER PLAN
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
GENERAL
SHEET NOTES
SHEET
KEYNOTES
1 VERIFY ALL EXISTING CONDITIONS BEFORE BID.
2 CONTRACTOR IS RESPONSIBLE FOR ALL DEVICES,
GEAR, CABLE, CONDUCTORS, TERMINATIONS,
OVERCURRENT PROTECTION DEVICES, AND HEAD
END EQUIPMENT AS PART OF THIS PROJECT.
3 CONTRACTOR IS RESPONSIBLE FOR ALL LINE
VOLTAGE AS PART OF THIS PROJECT. PROVIDE
LINE VOLTAGE REQUIRED TO ALL SYSTEMS
PROVIDED AS PART OF THIS PROJECT.
COORDINATE WITH ALL OTHER DISCIPLINES AND
DRAWINGS.
4 ALL RACEWAYS SHALL BE CONCEALED IN WALLS,
FLOORS, AND CEILING UNLESS OTHERWISE
NOTED. INSTANCES WHERE EXPOSED OR
SURFACE MOUNTED RACEWAYS IS REQUIRED A
ROUTING SKETCH SHALL BE PROVIDED TO
ARCHITECT AND ENGINEER. RACEWAY TYPE
SHALL BE SELECTED BY ENGINEER. FINISH OF
RACEWAY SHALL BE SELECTED BY ARCHITECT.
5 PROVIDE A NEW DEVICE AND TRIM PLATE IN
EXISTING DEVICE LOCATION. THE DEVICE SHALL
MATCH EXISTING TYPE OR AS SHOWN WHICHEVER
IS MORE STRINGENT. PROVIDE NEW RACEWAYS
AND CONDUCTORS ONLY AS REQUIRED.
6 PROVIDE NEW CIRCUIT BREAKERS IN EXISTING
PANEL FOR ALL NEW CIRCUITS. FIELD VERIFY
PANELBOARD TYPE AND BREAKER TYPE.
7 LOCATIONS OF MECHANICAL EQUIPMENT SHOWN
IS APPROXIMATE. COORDINATE EXACT LOCATIONS
OF MECHANICAL EQUIPMENT WITH MECHANICAL
DRAWINGS AND INSTALLER PRIOR TO ROUGH-IN.
NORTH
1/16" = 1'-0"F1
OVERALL GROUND FLOOR POWER PLAN 0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
1 PROVIDE CIRCUIT BREAKER IN EXISTING
SWITCHGEAR AND FEEDER AS DIRECTED ON
SHEET 02-EP601 PARTIAL ONE-LINE DIAGRAMS.
1CA
1B00A
1A
A
1C30
1C28
1C26
1C24
1C22
1C31
1C29
1C27
1C25
1C23
1C21
1C19B
1C19
1C19A
1C17
1C15
1C13
1C11
1C09
1C07
1C05
1D37
1A02
1B09
1BE2
1B11A
1B11
1D
C
1D00
1D27
1D27A
1D30A
1D30
1D28
1D
A
1D28A
1DA
1D35
1D00B
1D26
1D33
1D24
1D31
1D29
1D22
1D29A
1D05AA
1D031D01
1D00D
1D05
1D05A
1D07
1DB
1D13
1D11
1D09
1D04
1D15
1D02
1D17A
1D17
1D06
1D10
1D08
1D19
1D14
1D12
1D21
1D20
1D18
1D16
1D25
1D23
1D23A
1C
A
1B00AA
1BA
1B02
1B08
1B06
1BE1
1B00
1B05A
1B05
1B07
1B03
1B00B 1B01
1A35
1A03A
1A03
1A01
1A05
1A07 1A091A11
1A13
1A15
1A17
1A19
1A21 1A23
1A25
1A04 1A06
1A08
1A12
1A10
1A14
1A16
1A26 1A24A
1A32
1A34
1A36
1A38 1A40
1A42
1A44
1A45
1A25A
1A27
1A29
1A41
1A43
1A45A
1C37
1C35 1C39
1C43
1C41
1C471C45
1C33
1C10A
1C08
1C06
1C06A
1C12
1C10
1C02
1C14
1C16 1C18
1C20
1C36
1C40A
1C00DA
1C32
1C40
1C38
1C34
1C40B
1C00DB
1C42
1A22A
1C04
1C01 1C03
1B04
1A31
1A39
1A37
1A00
1A47
1A51
1A49
1A45B
1AA
1A28
1A30
1A24
1A28A
1A22
1A20
1A18
1A53D
1A53C
1A53B
1A53A
1A53
1A50 1A48 1A46
1A44A
1A
B
STAIR
HALLWAY (TO LOBBY)
C O
R R
ID
O
R
MECHANICAL RM
BREAKROOM
TOILET (MEN,151)
PIPE CHASE (138)
TOILET (WOMEN,151)
TELE/DATA (142)
ELECTRICAL (138)
OFFICE
OFFICE (3-WRKSTNS,151)
OFFICE (2-WRKSTNS,151)
OFFICE (2-WRKSTNS,151)
OFFICE (2-WRKSTNS,151)
OFFICE
OFFICE
OFFICE (2-WRKSTNS,151)
OFFICE (4-WRKSTNS,151)
OFFICE
CONFERENCE
OFFICE
STORAGE
STORAGE (138E)
UTILITY ROOM
OFFICE (182-SOCIAL WRKR)
ELECTRCAL
ELEVATOR
OFFICE/STORAGE (EA ASSN
ENTRY
C O
R R
ID
O
R
CORRIDOR
OFFICE
OFFICE
OFFICE
LAB #01
LAB #02
C O
R R
ID
O
R
OFFICE
STAIR LEVEL
AUX.SYS
CORRIDOR
INSTRUMENTS
INSTRUMENTS
DARKROOM
STORAGE
LAB #03
OFFICE
OFFICE
OFFICE (138)
LAB(151,4-WRKSTNS)
CORRIDOR
LAB #08
LAB #09
ELECTRICAL
STAIR
LAB (BONE)
LAB (BONE)
TEL/DATA
DARKROOM
LAB (BONE)
STORAGE
OFFICE
LAB
COLD ROOM
OFFICE
OFFICE
LAB #06
TOILET (WOMEN)
OFFICE
LAB (BONE)
OFFICE DESK
TOILET (MEN)
HAC
LAB #04
LAB #05
OFFICE
C O
R R
ID
O
R
LOBBY (B.02)
STAIR
FIRE EQUIPMENT
VENDING (CANTEEN)
TOILET (WOMEN)
ELEVATOR
CORRIDOR
OFFICE (122)
OFFICE (122)
ELECTRICAL
OFFICE
(TO OFFICES)
OFFICE (114)
KITCHEN (136)
COMPUTER
OFFICE
STORAGE
OFFICE
OFFICE
OFFICEOFFICE
CONFERENCE/TRAINING (136)
OFFICE
OFFICE (136,SUPVSR)
OFFICES (136,3-WRKSTNS)
OFFICES (136,6-WRKSTNS)
OFFICE
OFFICE
CONFERENCE
SHOWER/TOILET (WOMEN)
WOMENS TOILET
FIRE EQUIPMENT
COPIER
OFFICE
OFFICE
(SUPPLIES)
CHASE)
STORAGE
ELECTRICAL
TEL/DATA
TEL/DATA
FIRE EQUIPMENT
OFFICE (182-SOC WKR)
OFFICE
ENTRY
OFFICE
PIPE CHASE
RESTROOM MEN
OFFICE
OFFICE
OFFICE
OFFICE
INVESTIGATOR) OFFICE
LAB (TISSUE)
LAB (TISSUE)
LAB (TISSUE)LAB (TISSUE)
HAC (137)
(UNISEX)
WORKROOM
OFFICE (151,WRKSTNS)
(UNISEX)
OFFICE
OFFICE (151,3-WRKSTNS)
OFFICE (3-WRKSTNS,151)
OFFICE (151,DATA MGR)
OFFICE
LAB (UofU/151)
CONFERENCE
PREP
OFFICE
ICE MACHINE
OFFICE
(TO LAB)
COLDROOM
OFFICE
OFFICE
EYEWASH
LAB (BIOCHEM)
OFFICE
STORAGE
(182T,SW CONSULT)
OFFICE
TOILET (MEN)
PIPE CHASE
HAC
(UNISEX)
CORRIDOR
OFFICE/EXAM
BED ROOM (2-BED)
OFFICE/EXAM
STORAGE
STAIRS
OFFICE
OFFICE
OFFICE
(UNISEX)
BREAKROOM
OFFICE (182 FELLOWS)
OFFICE
OFFICE/EXAM
OFFICE/EXAM
OFFICE/EXAM
WAITING
ENTRY
OFFICE OFFICE
OFFICE (GULF WAR)
(PATIENT)
TOILET/SHOWER
STORAGE
(PIPE
MECH
TOILET
HALLWAY
OFFICE OFFICE (151- LAB #07
TOILETTOILET
TOILET
C O
R R
ID
O
R
ENTRY
CORRIDOR
CORRIDOR
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
UP
DN
T
T
TT
T
T
02-EP402
B6
02-EP402
F3
02-EP402
E6
02-EP402
C6
02-EP402
F6
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:0
A
M
02-EP110
OVERALL FIRST FLOOR POWER
PLAN
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
NORTH
1/16" = 1'-0"F1
OVERALL FIRST FLOOR POWER PLAN
GENERAL
SHEET NOTES
SHEET
KEYNOTES
1 VERIFY ALL EXISTING CONDITIONS BEFORE BID.
2 CONTRACTOR IS RESPONSIBLE FOR ALL DEVICES,
GEAR, CABLE, CONDUCTORS, TERMINATIONS,
OVERCURRENT PROTECTION DEVICES, AND HEAD
END EQUIPMENT AS PART OF THIS PROJECT.
3 CONTRACTOR IS RESPONSIBLE FOR ALL LINE
VOLTAGE AS PART OF THIS PROJECT. PROVIDE
LINE VOLTAGE REQUIRED TO ALL SYSTEMS
PROVIDED AS PART OF THIS PROJECT.
COORDINATE WITH ALL OTHER DISCIPLINES AND
DRAWINGS.
4 ALL RACEWAYS SHALL BE CONCEALED IN WALLS,
FLOORS, AND CEILING UNLESS OTHERWISE
NOTED. INSTANCES WHERE EXPOSED OR
SURFACE MOUNTED RACEWAYS IS REQUIRED A
ROUTING SKETCH SHALL BE PROVIDED TO
ARCHITECT AND ENGINEER. RACEWAY TYPE
SHALL BE SELECTED BY ENGINEER. FINISH OF
RACEWAY SHALL BE SELECTED BY ARCHITECT.
5 PROVIDE A NEW DEVICE AND TRIM PLATE IN
EXISTING DEVICE LOCATION. THE DEVICE SHALL
MATCH EXISTING TYPE OR AS SHOWN WHICHEVER
IS MORE STRINGENT. PROVIDE NEW RACEWAYS
AND CONDUCTORS ONLY AS REQUIRED.
6 PROVIDE NEW CIRCUIT BREAKERS IN EXISTING
PANEL FOR ALL NEW CIRCUITS. FIELD VERIFY
PANELBOARD TYPE AND BREAKER TYPE.
7 LOCATIONS OF MECHANICAL EQUIPMENT SHOWN
IS APPROXIMATE. COORDINATE EXACT LOCATIONS
OF MECHANICAL EQUIPMENT WITH MECHANICAL
DRAWINGS AND INSTALLER PRIOR TO ROUGH-IN.
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
CG
CG
CG
CG
CG
CG
CGCG
CGCG
CG
CGCG
CG CG
CG CG
CGCG
CG
CG
CG
CG
UP
D O W N
DOWN
2C00
2B05
2BA
2A19B
2D00
2D00A
2D00B
2D00C
2D00D
2CAA
2CA
2D32D
2D26
2D24
2D22
2D20
2D18A
2D18
2D16 2D14
2D14A
2D12
2D10
2DO8
2DO6
2D02
2DO4
2D01
2D03
2D07A
2D07
2D09
2DB
2D11
2D13
2D15A
2D15
2D17
2D19
2D21
2D21A
2D23A
2D23
2D25
2D27
2D28
2D30
2DA
2D31
2D29
2D34 2D32F
2D32E
2D32C
2D32B 2D32A
2D32
2C42
2C42A
2C40A
2C38
2C36
2C34A
2C34
2C43
2C41 2C39
2C33
2C31
2C29
2C27
2C25
2C23
2C21
2C192C17
2C15
2C13
2C11
2C09
2C07
2C05A
2C05
2C30
2C26
2C28
2C24
2C22
2C20A 2C20B
2C20
2C18A 2C18B
2C18
2C16
2C14
2C12
2C10
2C10A
2D05
2C08
2C32
2C35
2C00
2B03C
2B00
2BE2
2B07
2B01
2BO3B2B03A
2B08
2B02
2BE1
2B
A
2B04A
2BAA
2A20
2A22
2A
A
2A08
2A
B
2A10
2A12
2A00
2A09 2A03
2A05
2A13
2A11
2A17
2A19A
2A23
2A25
2A00AA
2A29
2A36 2A32
2A28
2A30
2A14
2AAA
2AA
2A18
2A02A 2C37
2C40
2C03 2C01
2A06A
2C06
2C04
2C02
2B03D
2B09
2B03
2B08A
2B06
2BO4
2A01
2A15
2A21
2A07
2A02
2A19
2A06
2A04
2A26
2A24
2A14A
2A27
2A27A
2A34
2A31
2A38
2A33 2A07A
2A16
CORRIDOR
CONFERENCE ROOM (151)
OFFICE, PSYCH
CORRIDOR (TO D-ZONE,EAST)
CORRIDOR (TO LABS)
CORRIDOR (LABS)
CORRIDOR (TO LABS)
(TO D-ZONE,NORTH)
ROOF ACCESS
STAIR
OFFICE
OFFICE (151)
OFFICE
OFFICE
SHOWER
/DRESS (151)
MEN
HAC WOMEN
DRESS (151)
FREZER
OFFICE
OFFICE
ICE
BREAK RM.
STORAGE
LAB
OFFICE
LAB
LAB 1
STO.
STAIR
ELEC.
DATA
OFFICE
LAB 2
LAB 3
LAB 4
LAB 5
OFFICE
TISSUE CULTURE
LAB 6
LAB 7
FREZER
BREAK RM.
CONFERENCE
STAIRS
ELEC.
DATA
STO.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICES
LAB
TC
TC
EXAM
TOILET
EXAM
LAB/FREZER
LAB
LAB/FREZER
STO.
ELEC.
OFFICE
CONFERENCE
OFFICE
OFFICE
OFFICE
OFFICEOFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
EXAM
OFFICE
BREAK
MECH.
MEN
WOMEN
OFFICE
OFFICE OFFICE
MEETING
OFFICE
OFFICE
MEETING
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STO.
STO.
CORRIDOR
OFFICE ( )
CORRIDOR
ELEVATOR
TEL/DATA
KITCHEN
OFFICE ( )OFFICE ( )
STORAGE (151)
FIRE EQUIPMENT
ELEVATOR
LO
B
B Y
(E
LE
V A
T O
R
TOILET (UNISEX)
STAIR (TO ROOF)
ELECTRICAL
OFFICE (151)
C O
R R
ID
O
R
REFRIGERATOR (WALK-IN)
C O
R R
ID
O
R
LAB.OFFICE (151)
LAB/OFFICE (151)
CORRIDOR
LAB (151)
OFFICE (151)
BREAK ROOM
LAB (151)
DARKROOM
LAB (151)
OFFICE (151)
STORAGE (SUPPLY)
TOILET (UNISEX)
MECH (PIPE CHASE)
REFRIGERATOR (WALK-IN)
LAB (151) OFFICE (151)
FIRE EQUIPMENT
LAB (151)
OFFICE (151)
ROOF ACCESS
STAIR
REFRIGERATOR (WALK-IN)
STORAGE COMP LAB
LAB
OFFICES (182,7-WRKSTNS)
CONFERENCE (151)
(UNISEX)
OFFICE
(EDUCATION MNGR)
OFFICE (ED-05)
OFFICE
OFFICE
SHOP, ELEC.
TOILET (UNISEX)
RECEPTION
OFFICE
STAIR
LAB
OFFICE (151)
LAB
LAB
FREEZER
CONFERENCE ROOM
TEL/DATA
FIRE EQUIPMENT
STORAGE (SUPPLY)
AUX.SYS
STORAGE
GLASS WARE WASHING LAB
STORAGE
LAB
LAB
LAB
LAB
OFFICE
TOILET
CORRIDOR
SHOWER/
SHOWER/
(UNISEX)
TOILET
(REFRIGERATOR)
EQUIPMENT
CORRIDOR
CORRIDOR
T
T
T
T
T
02-EP402
E4
02-EP402
C2
02-EP402
B4
02-EP402
E2
02-EP402
C4
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:1
A
M
02-EP120
OVERALL SECOND FLOOR POWER
PLAN
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
NORTH
1/16" = 1'-0"F1
OVERALL SECOND FLOOR POWER PLAN
GENERAL
SHEET NOTES
SHEET
KEYNOTES
1 VERIFY ALL EXISTING CONDITIONS BEFORE BID.
2 CONTRACTOR IS RESPONSIBLE FOR ALL DEVICES,
GEAR, CABLE, CONDUCTORS, TERMINATIONS,
OVERCURRENT PROTECTION DEVICES, AND HEAD
END EQUIPMENT AS PART OF THIS PROJECT.
3 CONTRACTOR IS RESPONSIBLE FOR ALL LINE
VOLTAGE AS PART OF THIS PROJECT. PROVIDE
LINE VOLTAGE REQUIRED TO ALL SYSTEMS
PROVIDED AS PART OF THIS PROJECT.
COORDINATE WITH ALL OTHER DISCIPLINES AND
DRAWINGS.
4 ALL RACEWAYS SHALL BE CONCEALED IN WALLS,
FLOORS, AND CEILING UNLESS OTHERWISE
NOTED. INSTANCES WHERE EXPOSED OR
SURFACE MOUNTED RACEWAYS IS REQUIRED A
ROUTING SKETCH SHALL BE PROVIDED TO
ARCHITECT AND ENGINEER. RACEWAY TYPE
SHALL BE SELECTED BY ENGINEER. FINISH OF
RACEWAY SHALL BE SELECTED BY ARCHITECT.
5 PROVIDE A NEW DEVICE AND TRIM PLATE IN
EXISTING DEVICE LOCATION. THE DEVICE SHALL
MATCH EXISTING TYPE OR AS SHOWN WHICHEVER
IS MORE STRINGENT. PROVIDE NEW RACEWAYS
AND CONDUCTORS ONLY AS REQUIRED.
6 PROVIDE NEW CIRCUIT BREAKERS IN EXISTING
PANEL FOR ALL NEW CIRCUITS. FIELD VERIFY
PANELBOARD TYPE AND BREAKER TYPE.
7 LOCATIONS OF MECHANICAL EQUIPMENT SHOWN
IS APPROXIMATE. COORDINATE EXACT LOCATIONS
OF MECHANICAL EQUIPMENT WITH MECHANICAL
DRAWINGS AND INSTALLER PRIOR TO ROUGH-IN.
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
.8
.4
.3
.7
6.
.0
.2
6.
2.
.1
.2
.2
.1
.5
.7
.2
6.
+9
+9
+9 +0
+9
+9
+9
+0
+1
+9
+10
+9
+9
+9
+0
+9
+9
+8
+10
+8
+0
3C00
3C00A
3B00 3A00A
3A00
MECHANICAL
MECHANICAL
PENTHOUSE (ELEVATOR)
MECHANICAL
MECHANICAL
TRUE NORTH PROJECT NORTH
2-1-D-E-P2-1
SS-1
2-1-D-E-P2-6,8,10
SS-1
2-1-D-E-P2-9,11,13
2-1-D-E-P2-3
SS-1
2-1-D-E-P2-15,17,19
SS-1
2-1-D-E-P2-18,20,22
SS-1
2-1-D-E-P2-12,14,161
2-2-B-E-P1-8
SS-1
2-2-B-E-P1-31,33,35
SS-1
2-2-B-E-P1-37,39,41
SS-1
2-2-B-E-P1-2,4,6
2-2-B-E-P1-29
SS-1
2-2-B-E-P1-23,25,27
SS-1
2-2-B-E-P1-17,19,21
SS-1
2-2-B-E-P1-11,13,15
2-1-A-E-P2-1 SS-1
2-1-A-E-P2-10,12,14
SS-1
2-1-A-E-P2-7,9,11
SS-1
2-1-A-E-P2-13,15,17
W
W
W
W
W
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:2
A
M
02-EP130
OVERALL ROOF POWER PLAN EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
GENERAL
SHEET NOTES
SHEET
KEYNOTES
1 VERIFY ALL EXISTING CONDITIONS BEFORE BID.
2 CONTRACTOR IS RESPONSIBLE FOR ALL DEVICES,
GEAR, CABLE, CONDUCTORS, TERMINATIONS,
OVERCURRENT PROTECTION DEVICES, AND HEAD
END EQUIPMENT AS PART OF THIS PROJECT.
3 CONTRACTOR IS RESPONSIBLE FOR ALL LINE
VOLTAGE AS PART OF THIS PROJECT. PROVIDE
LINE VOLTAGE REQUIRED TO ALL SYSTEMS
PROVIDED AS PART OF THIS PROJECT.
COORDINATE WITH ALL OTHER DISCIPLINES AND
DRAWINGS.
4 ALL RACEWAYS SHALL BE CONCEALED IN WALLS,
FLOORS, AND CEILING UNLESS OTHERWISE
NOTED. INSTANCES WHERE EXPOSED OR
SURFACE MOUNTED RACEWAYS IS REQUIRED A
ROUTING SKETCH SHALL BE PROVIDED TO
ARCHITECT AND ENGINEER. RACEWAY TYPE
SHALL BE SELECTED BY ENGINEER. FINISH OF
RACEWAY SHALL BE SELECTED BY ARCHITECT.
5 PROVIDE A NEW DEVICE AND TRIM PLATE IN
EXISTING DEVICE LOCATION. THE DEVICE SHALL
MATCH EXISTING TYPE OR AS SHOWN WHICHEVER
IS MORE STRINGENT. PROVIDE NEW RACEWAYS
AND CONDUCTORS ONLY AS REQUIRED.
6 PROVIDE NEW CIRCUIT BREAKERS IN EXISTING
PANEL FOR ALL NEW CIRCUITS. FIELD VERIFY
PANELBOARD TYPE AND BREAKER TYPE.
7 LOCATIONS OF MECHANICAL EQUIPMENT SHOWN
IS APPROXIMATE. COORDINATE EXACT LOCATIONS
OF MECHANICAL EQUIPMENT WITH MECHANICAL
DRAWINGS AND INSTALLER PRIOR TO ROUGH-IN.
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
1 PROVIDE A SEPARATE 120 VOLT, 20 AMP, 1 PHASE
CIRCUIT AND WEATHER PROOF GFCI OUTLET
MOUNTED TO SIDE OF CONDENSING UNIT.
2 SPLIT CONDENSING UNIT LOCATED ON ROOF. SEE
MECHANICAL DRAWINGS FOR EXACT LOCATION.
NORTH
1/16" = 1'-0"1
OVERALL ROOF POWER PLAN
GC02A
TELEPHONE EQUIPMENT
ENTRY (TELEPHONE EQUIPMT/STORAGE)
TT ST
(PG4)
(PG4) (PG4) (PG4) (PG4)
(PG4)(PG4)(PG4)
"2-G-C-C-P5"
"2-G-C-E-P2"
2-G-C-C-P5-1,3,5
RACK-30
2-G-C-E-P2-15,17,19
RACK-30
2-G-C-E-P2-2
AC-1
2-G-C-E-P2-6,8
2-G-C-E-P2-4
2-G-C-E-P2-5
2-G-C-E-P2-3
2-G-C-E-P2-1
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:4
A
M
02-EP401
ENLARGED POWER PLANS EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
NORTH
1/4" = 1'-0"F7
ENLARGED TR GC02A-2 POWER PLAN
ID DESCRIPTION
NOMINAL SIZE
M O
U N
T
IN
G
T Y
P E
C O
L O
R T
E M
P
C R
I
D R
IV
E
R C
O N
F
IG
U R
A T
IO
N
V O
L T
A G
E
W A
T T
S
F
IN
IS
H
F
IX
T U
R E
L U
M E
N S
D
IF
F U
S E
R /L
E N
S
R E
F L
E C
T O
R
O P
T
IO
N S
N O
T E
S
MANUFACTURER (CATALOG SERIES)
L E
N G
T H
D E
P T
H
H E
IG
H
T
D
IA
M E
T E
R A
P E
R T
U R
E
OPTION 1 OPTION 2 OPTION 3
(PG4) STRIPLIGHT, GENERAL 48" 4" 4" - CP LED 4000K LED DRIVER
(0-10V DIMMING)
120/277 38 CBA 5000 - - - LITHONIA
(ZL1D-L48-5000LM-FST-M
VOLT-40K-80CRI-WH-HC3
6)
ILP (SS4) WILLIAMS (75R)
DIFFUSER/LENSFINISH PROVIDE UNIT PRICES AND FIXTURE BRAND SELECTED FOR ADD/DELETE CHANGES
FOR EACH FIXTURE TYPES SHOWN WITHIN 48 BUSINESS HOURS OF THE BID DATE.
FAILURE TO COMPLY WITH THIS REQUIREMENT MAY DISQUALIFY THE PRODUCTS
AND EMPOWER THE ENGINEER TO DETERMINE FAIR VALUE FOR FIXTURE AND
INSTALLATION CHANGES, WITHOUT FURTHER INPUT FROM THE CONTRACTOR OR
INSTALLER.
CONTRACTOR ALLOWANCE PRICES ARE ACCURATE WHEN THIS JOB WAS
SPECIFIED, CONTRACTOR AND ELECTRICAL DISTRIBUTOR SHALL VERIFY THIS
ALLOWANCE AND REPORT ANY PROBLEMS TO THE ENGINEER BEFORE THE BID.
ALLOWANCE PRICE MAY OR MAY NOT INCLUDE LAMP(S) OR FREIGHT AS NOTED,
AND DO NOT INCLUDE ANY TAXES.
SUBSTITUTIONS AND/OR EQUAL FIXTURES MUST RECEIVE APPROVAL PRIOR TO
BIDDING, THEY MUST BE SUBMITTED TO THE ENGINEER NO LESS THAN 2 WEEKS
PRIOR TO BID OPENING.
SAMPLES MUST BE PROVIDED FOR ANY AND ALL FIXTURES UPON A/E REQUEST
PRIOR TO RELEASING FIXTURES.
ALL FIXTURES SHALL BE LISTED AND APPROVED FOR THEIR INTENDED USE AND
LOCATION.
VERIFY THE PROPER MOUNTING KITS OR ACCESSORIES TO FACILITATE
INSTALLATION AS SHOWN AT EACH LOCATION ON THE DRAWINGS.
COMPLY WITH THE "INTERIOR LIGHTING" SECTION OF THE SPECIFICATIONS.
REFER TO SPECIFICATIONS FOR IMPORTANT TECHNICAL REQUIREMENTS FOR
LIGHTING FIXTURES, DRIVERS, AND LAMPS.
ALL LIGHT FIXTURES TO BE EITHER "DLC" OR "LIGHTING FACTS" LISTED OR TO BE
APPROVED BY ARCHITECT/ENGINEER AND OWNER.
LUMINAIRE OPTIONSMOUNTING REFLECTOR 1.
2.
3.
4.
5.
6.
7.
8.
9.
DIAMETER
H E
IG
H
T
LENGTH DEPTH
H E
IG
H
T
LENGTH
DEPTH
HEIGHT
NOTES
INTERIOR LIGHTING FIXTURE SCHEDULE
ABBREVIATIONS GENERAL NOTES
ARHR - AIR RETURN AND HEAT REJECTION
DL - DAMP LOCATION
EQC - EARTHQUAKE CLIPS
F - FUSING
HLD - HINGED AND LATCHED DOOR
HS - HOUSE SIDE SHIELD
PS - PHOTOCELL SWITCH
QRS - QUARTZ RESTRIKE
ST - STATIC
WG - WIRE GUARD
WL - WET LOCATION
B - BASE
C - CEILING
F - FLANGE
G - GRID
P - PENDANT
PL POLE
R - RECESSED
S - SURFACE
W - WALL
MW - MATTE WHITE
BL - BLACK
SL - SILVER
GL - GOLD
CL - CLEAR
PW - PAINTED WHITE
EA - EXTRUDED ALUMINUM
S - STEEL
GS - GALVANIZED STEEL
C - CAST
CBA - COLOR BY ARCHITECT
SCBA - STANDARD COLOR BY
ARCHITECT
CCA - CUSTOM COLOR BY
ARCHITECT
FS
209D
- MEETS FEDERAL
STANDARD 209D
TP - THERMALLY
PROTECTED
FL - FLUSH
R - REGRESS
M - MITERED
OP - NONE/OPEN
SP - SPECULAR
SS - SEMI-SPECULAR
D - DIFFUSE (WHITE ENAMEL)
SC - SPECULAR (COLORED)
PR - PRISMATIC
FDR - FULL DEPTH REFLECTOR
DS - DIFFUSE (SEMI SPECULAR) SILVER
LI - LOW IRIDESCENT
IR - IRIDESCENT
SL - SILVER
GL - GOLD
CA - CLEAR ALZAK
#A - ACRYLIC #THICK
#OA - ACRYLIC #THICK (OPAL)
GC - GLASS (CLEAR)
GO - GLASS (OPAL)
GF - GLASS (FROSTED)
SGL - SOFT GLOW LENS
HPL - HIGH PERFORMANCE LENS
DO - DROP OPAL
CGL - CONVEX GLASS LENS
S - SATIN LENS
GENERAL
SHEET NOTES
SHEET
KEYNOTES
1 VERIFY ALL EXISTING CONDITIONS BEFORE BID.
2 CONTRACTOR IS RESPONSIBLE FOR ALL DEVICES,
GEAR, CABLE, CONDUCTORS, TERMINATIONS,
OVERCURRENT PROTECTION DEVICES, AND HEAD
END EQUIPMENT AS PART OF THIS PROJECT.
3 CONTRACTOR IS RESPONSIBLE FOR ALL LINE
VOLTAGE AS PART OF THIS PROJECT. PROVIDE
LINE VOLTAGE REQUIRED TO ALL SYSTEMS
PROVIDED AS PART OF THIS PROJECT.
COORDINATE WITH ALL OTHER DISCIPLINES AND
DRAWINGS.
4 ALL RACEWAYS SHALL BE CONCEALED IN WALLS,
FLOORS, AND CEILING UNLESS OTHERWISE
NOTED. INSTANCES WHERE EXPOSED OR
SURFACE MOUNTED RACEWAYS IS REQUIRED A
ROUTING SKETCH SHALL BE PROVIDED TO
ARCHITECT AND ENGINEER. RACEWAY TYPE
SHALL BE SELECTED BY ENGINEER. FINISH OF
RACEWAY SHALL BE SELECTED BY ARCHITECT.
5 PROVIDE A NEW DEVICE AND TRIM PLATE IN
EXISTING DEVICE LOCATION. THE DEVICE SHALL
MATCH EXISTING TYPE OR AS SHOWN WHICHEVER
IS MORE STRINGENT. PROVIDE NEW RACEWAYS
AND CONDUCTORS ONLY AS REQUIRED.
6 PROVIDE NEW CIRCUIT BREAKERS IN EXISTING
PANEL FOR ALL NEW CIRCUITS. FIELD VERIFY
PANELBOARD TYPE AND BREAKER TYPE.
7 LOCATIONS OF MECHANICAL EQUIPMENT SHOWN
IS APPROXIMATE. COORDINATE EXACT LOCATIONS
OF MECHANICAL EQUIPMENT WITH MECHANICAL
DRAWINGS AND INSTALLER PRIOR TO ROUGH-IN.
1 PROVIDE AN OVERHEAD POWER DROP CORD WITH
A 30 AMP 208 VOLT THREE-PHASE TWISTED LOCK
RECEPTACLE (L21-30R); 8.5 FT AFF (WYE(5-WIRE))
COORDINATE INSTALLATION LOCATION WITH
TELECOMMUNICATIONS CONTRACTOR. SEE SHEET
EE002, EE501, AND PANEL SCHEDULE. PROVIDE
ONE POWER DIST. (2RU), FOUR UPS (6RU), AND SIX
PDU FOR EXISTING TWO RACKS. EXISTING RACKS
ARE TO REMAIN. CONTRACTOR TO COORDINATE
INSTALLATION OF NEW PDU, POWER DIST. (2RU),
AND UPS (6RU) ON EXISTING RACK
CONFIGURATION.
2 SECONDARY BONDING BUSBAR (SBB). SEE ET
SHEETS FOR PLACEMENT AND GROUNDING
DETAIL. CONTRACTOR TO PROVIDE A SEPARATELY
DERIVED #3/0 GROUND FROM BUILDING GROUND
TO TR BUSBARS. CONTRACTOR TO VERIFY
BUSBAR’S RESISTANCE IS UNDER 4 OHMS
MEASURED BY THE FOUR POINT
FALL-OF-POTENTIAL METHOD PER IEEE 81.
3 PROVIDE A 225 AMP, THREE-PHASE, FOUR WIRE,
208 VOLT SERVICE PANEL. PANEL SHALL BE
EQUIPPED WITH A POWER METER.
4 PROVIDE THERMAL SWITCH FOR SPLIT SYSTEM.
THERMAL SWITCH TO BE MOUNTED ON SIDE OF
UNIT.
5 COORDINATE NEW POWER CONFIGURATION WITH
EXISTING RACKS AND EQUIPMENT.
0' 2' 4' 8' 16'
GRAPHIC SCALE 1/4" = 1'-0"
1'
Revision 1 Date 1 06/08/23
GD03
GD05
ELECTRICAL
TEL/DATAT
S
T
GA28
GA30
TEL/DATA (142)
AUX.SYS (138)
T
ST
GB03
GB01
TEL/DATA
ELECTRICAL
TH
S T
S T
GC19
GC21
ELECTRICAL
TEL/DATA
STAIR/VESTIBULE
TH
S T
S T
1D37
1D35
UTILITY ROOM
AUX.SYS
T
ST
1B09
1B07
ELECTRCAL
ELECTRICAL
T
ST
1C31
TELE/DATA (142)
CG
TT
ST
1D07
1D09
ELECTRICAL
TEL/DATA
TS
T
1A34
1A36
1AA
ELECTRICAL
TEL/DATA
STAIRS
T S
T
2D13
DATA
T S
T
2D31
2D29
ELEC.
DATA
T
ST
2B05
2B07
TEL/DATA
SHOP, ELEC.
T ST
CG
2C33
2C31
STO.
ELEC.
T ST
2A24
TEL/DATAT
ST
"2-G-D-E-P3"
W-RACK-30
2-1-D-C-P7
W-RACK-30
2-1-D-E-P1
AC-1
2-G-D-E-P3-1,3
1 1
W-RACK-30
2-1-A-C-P3
W-RACK-30
2-1-A-E-P2
AC-1
2-1-A-E-P2-3,5
"2-G-B-C-P1"
W-RACK-30
2-G-B-C-P1
AC-1
2-1-B-E-P1
"2-G-B-E-P1"
W-RACK-30
2-G-B-E-P1 HM-1
2-1-B-E-P1
"2-G-C-E-P1"
"2-G-C-C-P1"
W-RACK-30
2-G-C-C-P1
W-RACK-30
2-G-C-E-P1
AC-1
2-G-C-E-P1
HM-1
2-G-C-E-P1
1 1
"2-1-D-C-P5" "2-1-D-C-P6"
"2-1-D-C-P8" "2-1-D-E-P2"
W-RACK-30
2-1-D-C-P8
W-RACK-30
2-1-D-E-P2
AC-1
2-1-D-E-P2-2,4
"2-1-B-C-P1"
"2-1-B-E-P1"
1 1 2
W-RACK-30
2-1-B-E-P1
W-RACK-30
2-1-B-C-P1
AC-1
2-1-B-E-P1-11,13
1 1
W-RACK-30
2-G-C-C-P5
W-RACK-30
2-G-C-E-P2
AC-1
2-G-C-E-P2-10,12
"2-1-D-C-P2"
"2-1-D-C-P1"
"2-1-D-C-P7"
"2-1-D-E-P1"W-RACK-30
2-1-D-E-P1
W-RACK-30
2-1-D-C-P7
AC-1
2-1-D-E-P1-1,3
"2-1-A-C-P2"
"2-1-A-E-P1"
1 2
"2-1-A-C-P3"
"2-1-A-E-P2"
W-RACK-30
2-1-A-C-P3
W-RACK-30
2-1-A-E-P2
AC-1
2-1-A-E-P2-2,4
W-RACK-30
2-1-D-C-P7
W-RACK-30
2-1-D-E-P1
AC-1
2-1-D-E-P1-2,4
1 1
W-RACK-30
2-1-D-C-P8
W-RACK-30
2-1-D-E-P2
AC-1
2-1-D-E-P2-5,7
1 1
"2-2-B-C-P1"
"2-2-B-E-P1"
W-RACK-30
2-2-B-C-P1
W-RACK-30
2-2-B-E-P1
AC-1
2-2-B-E-P1
1 1
W-RACK-30
2-G-C-E-P2
W-RACK-30
2-G-C-C-P5
AC-1
2-G-C-E-P2-7,9
1 2
W-RACK-30
2-1-A-C-P3
W-RACK-30
2-1-A-E-P2
AC-1
2-1-A-E-P2-6,8
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
E
L E
C .r v t
/8
/2
:1
:5
A
M
02-EP402
ENLARGED POWER PLANS EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 02
08 JUN 2023 ARNOLD,
FELT
TAYLOR,
SOUTHERN
GENERAL
SHEET NOTES
SHEET
KEYNOTES
1 VERIFY ALL EXISTING CONDITIONS BEFORE BID.
2 CONTRACTOR IS RESPONSIBLE FOR ALL DEVICES,
GEAR, CABLE, CONDUCTORS, TERMINATIONS,
OVERCURRENT PROTECTION DEVICES, AND HEAD
END EQUIPMENT AS PART OF THIS PROJECT.
3 CONTRACTOR IS RESPONSIBLE FOR ALL LINE
VOLTAGE AS PART OF THIS PROJECT. PROVIDE
LINE VOLTAGE REQUIRED TO ALL SYSTEMS
PROVIDED AS PART OF THIS PROJECT.
COORDINATE WITH ALL OTHER DISCIPLINES AND
DRAWINGS.
4 ALL RACEWAYS SHALL BE CONCEALED IN WALLS,
FLOORS, AND CEILING UNLESS OTHERWISE
NOTED. INSTANCES WHERE EXPOSED OR
SURFACE MOUNTED RACEWAYS IS REQUIRED A
ROUTING SKETCH SHALL BE PROVIDED TO
ARCHITECT AND ENGINEER. RACEWAY TYPE
SHALL BE SELECTED BY ENGINEER. FINISH OF
RACEWAY SHALL BE SELECTED BY ARCHITECT.
5 PROVIDE A NEW DEVICE AND TRIM PLATE IN
EXISTING DEVICE LOCATION. THE DEVICE SHALL
MATCH EXISTING TYPE OR AS SHOWN WHICHEVER
IS MORE STRINGENT. PROVIDE NEW RACEWAYS
AND CONDUCTORS ONLY AS REQUIRED.
6 PROVIDE NEW CIRCUIT BREAKERS IN EXISTING
PANEL FOR ALL NEW CIRCUITS. FIELD VERIFY
PANELBOARD TYPE AND BREAKER TYPE.
7 LOCATIONS OF MECHANICAL EQUIPMENT SHOWN
IS APPROXIMATE. COORDINATE EXACT LOCATIONS
OF MECHANICAL EQUIPMENT WITH MECHANICAL
DRAWINGS AND INSTALLER PRIOR TO ROUGH-IN.
NORTH
1/4" = 1'-0"F8
ENLARGED EXISTING TEL/DATA
GD05 POWER PLAN
1 PROVIDE AN OVERHEAD POWER DROP CORD WITH
A 30 AMP 208 VOLT THREE-PHASE TWISTED LOCK
RECEPTACLE (L21-30R); 8.5 FT AFF (WYE(5-WIRE))
COORDINATE INSTALLATION LOCATION WITH
TELECOMMUNICATIONS CONTRACTOR. SEE SHEET
EE002, EE501, AND PANEL SCHEDULE. PROVIDE
ONE POWER DIST. (2RU), FOUR UPS (6RU), AND SIX
PDU FOR EXISTING TWO RACKS. EXISTING RACKS
ARE TO REMAIN. CONTRACTOR TO COORDINATE
INSTALLATION OF NEW PDU, POWER DIST. (2RU),
AND UPS (6RU) ON EXISTING RACK
CONFIGURATION.
2 SECONDARY BONDING BUSBAR (SBB). SEE ET
SHEETS FOR PLACEMENT AND GROUNDING
DETAIL. CONTRACTOR TO PROVIDE A SEPARATELY
DERIVED #3/0 GROUND FROM BUILDING GROUND
TO TR BUSBARS. CONTRACTOR TO VERIFY
BUSBAR’S RESISTANCE IS UNDER 4 OHMS
MEASURED BY THE FOUR POINT
FALL-OF-POTENTIAL METHOD PER IEEE 81.
3 PROVIDE THERMAL SWITCH FOR SPLIT SYSTEM.
THERMAL SWITCH TO BE MOUNTED ON SIDE OF
UNIT.
4 PROVIDE A 225 AMP, THREE-PHASE, FOUR WIRE,
208 VOLT SERVICE PANEL. PANEL SHALL BE
EQUIPPED WITH A POWER METER.
NORTH
1/4" = 1'-0"E8
ENLARGED EXISTING TEL/DATA GA28 POWER PLAN
NORTH
1/4" = 1'-0"D8
ENLARGED EXISTING TEL/DATA GB03 POWER PLAN
NORTH
1/4" = 1'-0"B8
ENLARGED EXISTING TEL/DATA GC21 POWER PLAN
NORTH
1/4" = 1'-0"F6
ENLARGED EXISTING AUX SYS 1D35-2 POWER PLAN
NORTH
1/4" = 1'-0"E6
ENLARGED EXISTING TEL/DATA 1B09-2 POWER PLAN
NORTH
1/4" = 1'-0"C6
ENLARGED EXISTING TEL/DATA 1C31-2 POWER PLAN
NORTH
1/4" = 1'-0"B6
ENLARGED EXISTING TEL/DATA 1D09-2 POWER PLAN
NORTH
1/4" = 1'-0"F3
ENLARGED EXISTING TR 1A36-2 POWER PLAN
NORTH
1/4" = 1'-0"E4
ENLARGED EXISTING DATA 2D13-2 POWER PLAN
NORTH
1/4" = 1'-0"C4
ENLARGED EXISTING DATA 2D29-2 POWER PLAN
NORTH
1/4" = 1'-0"B4
ENLARGED EXISTING TEL/DATA 2B07-2 POWER PLAN
NORTH
1/4" = 1'-0"E2
ENLARGED EXISTING TEL/DATA 2C33-2 POWER PLAN
NORTH
1/4" = 1'-0"C2
ENLARGED EXISTING TR 2A24 POWER PLAN
0' 2' 4' 8' 16'
GRAPHIC SCALE 1/4" = 1'-0"
1'
SWITCHBOARD "2-G-B-E-D1"
SECTION I 208/120V 3Ø, 4W
800/3 "2DPE" (EXISTING)
SWITCHBOARD "2-G-B-C-D1"
208/120V 3Ø, 4W "2CMP2B"
(EXISTING)
225/3
225/3
"2-G-C-E-P2"
225/3
"2-1-D-E-P2"
225/3
"2-1-A-E-P2"
225/3
"2-1-D-E-P1"
225/3
225/3
225/3
225/3
225/3
"2-G-C-C-P5"
225/3
"2-1-D-C-P8"
225/3
"2-1-A-C-P3"
225/3
"2-1-D-C-P7"
225/3
225/3
225/3
GROUND FLOOR
FIRST FLOOR
F7
POWER RISER ONE-LINE DIAGRAM - BUILDING #02 - AREA "C"
NO SCALE
TR
GC02A-2
TR
1D07
TR
1A34
TR
1D37
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
S…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .