This document provides details for a federal construction contract opportunity. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting proposals for the EHRM Infrastructure Upgrades Construction project at the Salt Lake City VAMC. Attachment 4 contains drawings related to the project scope, which includes upgrades to infrastructure systems at the medical center. Proposals are due by January 15, 2023 under solicitation number 36C77623B0041. The contract award is expected in April 2023 for construction work to be completed by January 2024.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING DOOR TO BE REMOVED
EXISTING WALL TO BE REMOVED
EXISTING WALL TO REMAIN
DECONSTRUCTION PLAN GENERAL NOTES
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, AND NOTIFY THE ARCHITECT OF
ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THOSE DOCUMENTED
PRIOR TO COMMENCING DEMOLITION.
2. WHERE DEMOLITION OF PARTITION OCCURS ALL ITEMS IN AND ON PARTITION ARE TO
BE REMOVED, UNLESS NOTED OTHERWISE. WALL MOUNTED EQUIPMENT THE FACILITY
WISHES TO KEEP MUST BE REMOVED PRIOR TO DEMOLITION. ALL OTHER ITEMS ARE
TO BE DISPOSED OF BY THE CONTRACTOR, UNLESS NOTED OTHERWISE.
3. SEE MECHANICAL, ELECTRICAL, AND/OR PLUMBING DRAWINGS WHEN DEMOLITION
REQUIRES REMOVAL OR TERMINATION OF SUCH UTILITIES.
4. FOR THE ABATMENT OF HAZARDOUS MATERIALS, SEE GENERAL SHEET HR101.
5. PROTECT PREVIOUS CONSTRUCTION FROM DAMAGE.
6. ALL EXISTING FIXTURES, FURNITURE, AND EQUIPMENT TO BE RE-USED OR SALVAGED
BY THE FACILITY WILL BE REMOVED BY THE FACILITY PRIOR TO BEGINNING OF
CONSTRUCTION. ANY ITEMS LEFT BY THE FACILITY SHALL BE REMOVED BY THE
CONTRACTOR. CONTRACTOR HAS OPTION TO SALVAGE OR DISPOSE OF SUCH
EQUIPMENT.
7. DASHED LINES INDICATE ITEMS BEING DEMOLISHED. UNLESS NOTED OTHERWISE.
8. SHOULD FLOOR OR RATED WALL PENETRATIONS CANNOT BE FIRESTOPPED AT THE
END OF THE WORK SHIFT DUE TO THE NEED TO PULL ADDITIONAL CABLES,
TEMPORARY FIRESTOPPING COMPOSED OF MINERAL WOOL SHOULD BE INSTALLED IN
THE PENETRATION TO PROVIDE PROTECTION AGAINST FIRE/SMOKE SPREAD
THROUGH THE UNSEALED PENETRATION.
9. SHOULD THE CONTRACTOR IDENTIFY UPCOMING WORK THAT RESULTS IN A LONG-
TERM CEILING REMOVAL, DISCUSS WITH COR WHETHER A RATED ENCLOSURE MUST
BE CONSTRUCTED (OR TEMPORARY UPRIGHT SPRINKLERS INSTALLED).
10. THE REMOVAL OF CEILINGS IN TRS SHOULD BE DONE IN THE SAME WORK SHIFT
WHERE THE NEW UPRIGHT SPRINKLERS ARE INSTALLED. REMOVAL OF MORE THAN
ONE CEILING TILE WITHIN THE PROTECTION AREA OF A SPRINKLER CAN RENDER THE
SPRINKLER INEFFECTIVE DUE TO HEAT ENTERING THE CEILING PLENUM AND
BYPASSING THE SPRINKLER.
ACT LAY-IN CEILING
SYSTEM REMOVED
GYPSUM BOARD
CEILING SYSTEM
REMOVED
ACT LAY-IN CEILING
SYSTEM TO REMAIN
GYPSUM BOARD
CEILING SYSTEM TO
REMAIN
MED. ROOM
4A10CA-01
TRIAGE ROOM
4A12-01
02.68
02.53
02.63
02.63
02.68
02.02
02.02
02.02
02.02
02.53
02.59
02.52
02.52
02.52
02.04
TOILET (PATIENT)
4A03A-01
TOILET (PATIENT)
4A05A-01
02.5302.53
02.68 02.68
02.63 02.63
02.02 02.02
02.59
02.52
EXAM ROOM
4A07-01
TOILET (PATIENT)
4A07A-01
02.68
02.68
02.68
02.53
02.53
02.53
02.04 02.04
02.63
02.63
02.63
01.15
02.76
02.59
02.5202.52
02.03
02.58
02.63
02.79
02.79
02.79
02.79
02.79
02.79 02.79
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/3
/2
:2
:4
P
M
01-AD341
ENLARGED FOURTH FLOOR
DEMOLITION PLANS
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
DEMOLITION LEGEND
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
KEYED NOTES
01.15 COORDINATE DEMOLITION OF HEAD WALL WITH MEP DRAWINGS
02.02 EXISTING WALL TO REMAIN
02.03 EXISTING DOOR TO REMAIN
02.04 EXISTING WINDOW TO REMAIN
02.52 REMOVE EXISTING CRASH RAILS, SHOWN DASHED
02.53 REMOVE EXISTING WALL SHOWN DASHED
02.58 REMOVE EXISTING CORNER GUARD
02.59 REMOVE EXISTING GYPSUM WALL BOARD AS NEEDED FOR INSTALLATION OF NEW WALL
INSULATION, SEE NEW FLOOR PLAN LAYOUT AND NOTES
02.63 REMOVE EXISTING FLOORING
02.68 REMOVE EXISTING DOOR, FRAME AND HARDWARE
02.76 REMOVE EXISTING CASEWORK
02.79 REMOVE EXISTING CEILING AND SUPPORT SYSTEM
REFLECTED CEILING DECONSTRUCTION LEGEND
NORTH
3/8" = 1'-0"1
FOURTH FLOOR A WING - MED. ROOM/ TRIAGE ROOM - 4A10CA-01 DEMOLITION PLAN
NORTH
3/8" = 1'-0"3
FOURTH FLOOR A WING - TOILET (PATIENT) - 4A05A-01 DEMOLITION PLAN
NORTH
3/8" = 1'-0"2
FOURTH FLOOR A WING - EXAM ROOM - 4A07-01 DEMOLITION PLAN
NORTH
3/8" = 1'-0"4
FOURTH FLOOR A WING - MED. ROOM/ TRIAGE ROOM - 4A10CA-01 DEMOLITION RCP
NORTH
3/8" = 1'-0"5
FOURTH FLOOR A WING - EXAM ROOM - 4A07-01 DEMOLITION RCP
NORTH
3/8" = 1'-0"6
FOURTH FLOOR A WING - TOILET (PATIENT) - 4A05A-01 DEMOLITION RCP
Revisions: Date:
EXISTING DOOR TO BE REMOVED
EXISTING WALL TO BE REMOVED
EXISTING WALL TO REMAIN
ACT LAY-IN CEILING
SYSTEM REMOVED
GYPSUM BOARD
CEILING SYSTEM
REMOVED
ACT LAY-IN CEILING
SYSTEM TO REMAIN
GYPSUM BOARD
CEILING SYSTEM TO
REMAIN
WRKRM (HBHC STAFF)
5B08-01
02.68
02.02
02.02
02.0202.80
02.63
02.26
01.16
02.63
02.7902.20
DECONSTRUCTION PLAN GENERAL NOTES
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, AND NOTIFY THE ARCHITECT OF
ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THOSE DOCUMENTED
PRIOR TO COMMENCING DEMOLITION.
2. WHERE DEMOLITION OF PARTITION OCCURS ALL ITEMS IN AND ON PARTITION ARE TO
BE REMOVED, UNLESS NOTED OTHERWISE. WALL MOUNTED EQUIPMENT THE FACILITY
WISHES TO KEEP MUST BE REMOVED PRIOR TO DEMOLITION. ALL OTHER ITEMS ARE
TO BE DISPOSED OF BY THE CONTRACTOR, UNLESS NOTED OTHERWISE.
3. SEE MECHANICAL, ELECTRICAL, AND/OR PLUMBING DRAWINGS WHEN DEMOLITION
REQUIRES REMOVAL OR TERMINATION OF SUCH UTILITIES.
4. FOR THE ABATMENT OF HAZARDOUS MATERIALS, SEE GENERAL SHEET HR101.
5. PROTECT PREVIOUS CONSTRUCTION FROM DAMAGE.
6. ALL EXISTING FIXTURES, FURNITURE, AND EQUIPMENT TO BE RE-USED OR SALVAGED
BY THE FACILITY WILL BE REMOVED BY THE FACILITY PRIOR TO BEGINNING OF
CONSTRUCTION. ANY ITEMS LEFT BY THE FACILITY SHALL BE REMOVED BY THE
CONTRACTOR. CONTRACTOR HAS OPTION TO SALVAGE OR DISPOSE OF SUCH
EQUIPMENT.
7. DASHED LINES INDICATE ITEMS BEING DEMOLISHED. UNLESS NOTED OTHERWISE.
8. SHOULD FLOOR OR RATED WALL PENETRATIONS CANNOT BE FIRESTOPPED AT THE
END OF THE WORK SHIFT DUE TO THE NEED TO PULL ADDITIONAL CABLES,
TEMPORARY FIRESTOPPING COMPOSED OF MINERAL WOOL SHOULD BE INSTALLED IN
THE PENETRATION TO PROVIDE PROTECTION AGAINST FIRE/SMOKE SPREAD
THROUGH THE UNSEALED PENETRATION.
9. SHOULD THE CONTRACTOR IDENTIFY UPCOMING WORK THAT RESULTS IN A LONG-
TERM CEILING REMOVAL, DISCUSS WITH COR WHETHER A RATED ENCLOSURE MUST
BE CONSTRUCTED (OR TEMPORARY UPRIGHT SPRINKLERS INSTALLED).
10. THE REMOVAL OF CEILINGS IN TRS SHOULD BE DONE IN THE SAME WORK SHIFT
WHERE THE NEW UPRIGHT SPRINKLERS ARE INSTALLED. REMOVAL OF MORE THAN
ONE CEILING TILE WITHIN THE PROTECTION AREA OF A SPRINKLER CAN RENDER THE
SPRINKLER INEFFECTIVE DUE TO HEAT ENTERING THE CEILING PLENUM AND
BYPASSING THE SPRINKLER.
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/3
/2
:2
:4
P
M
01-AD350
ENLARGED FIFTH FLOOR
DEMOLITION PLANS
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
DEMOLITION LEGEND
REFLECTED CEILING DECONSTRUCTION LEGEND
GRAPHIC SCALE 3/8" = 1'-0"
4'2'0" 1' 8'1'32"
NORTH
3/8" = 1'-0"1
FIFTH FLOOR B-WING - WRKRM (HBHC STAFF) - 5B08A-01 DEMOLITON PLAN
NORTH
3/8" = 1'-0"2
FIFTH FLOOR B-WING - WRKRM (HBHC STAFF) - 5B08A-01 DEMOLITON RCP
KEYED NOTES
01.16 PROVIDE WALL RECESS FOR NEW FIRE EXTINGUISHER CABINET, MAINTAIN ALL
FIRE/SMOKE RATINGS
02.02 EXISTING WALL TO REMAIN
02.20 EXISTING CEILING TO REMAIN
02.26 EXISTING FLOORING TO REMAIN
02.63 REMOVE EXISTING FLOORING
02.68 REMOVE EXISTING DOOR, FRAME AND HARDWARE
02.79 REMOVE EXISTING CEILING AND SUPPORT SYSTEM
02.80 CUT OPENING IN EXISTING WALL FOR NEW DOOR, SEE FLOOR PLAN AND DOOR
SCHEDULE FOR SIZE AND LOCATION, VEIRFY LOCATION AND SIZE BEFORE DEMOLITION
OCCURES
AIR SHAFT
RAMP
DOWN
UP
UP
UP
UP
UP
UP
D WING
A WING
B WING
C WING
01-AE300
01-AE300
01-AE300
TR
TR
A A
A A
ROOM NOT
SPRINKLED
C
C B
B
GC10B-01
GC01-01
GA16-01
09.4809.48
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
2 HR. FIRE BARRIER
1 HR. FIRE BARRIER
SMOKE BARRIER
AREA OF CONSTRUCTION
EXISTING TELECOMMUNICATION SPACE
FIRE ALARM ZONE
WALL COVERING REMOVAL AND REPAIR
TR TELECOMMUNICATION ROOM
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/7
/2
:1
:3
P M
01-AE100
OVERALL GROUND FLOOR PLAN EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
NORTH
1/16" = 1'-0"1
OVERALL GROUND FLOOR PLAN
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
FLOOR PLAN LEGEND
ROOF
D U
M B
W A
IT
E
R
D WING
A WING
H WING
E WING
01-AE310
TR
01-AE311
01-AE311
TR
TR
A R E A N
O T
IN
S C O P E
FUTURE G
WING ADDITION
01-AE310
H D
H G
G
B
D
A
A A
B
C B C
E
B C
C F
C E
C F
B
A
B
F WING
B WING
C WING
1D42B-01
1E02-01
1A04-01
1A15A-01
09.4809.48
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
2 HR. FIRE BARRIER
1 HR. FIRE BARRIER
SMOKE BARRIER
AREA OF CONSTRUCTION
EXISTING TELECOMMUNICATION SPACE
FIRE ALARM ZONE
WALL COVERING REMOVAL AND REPAIR
TR TELECOMMUNICATION ROOM
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/7
/2
:1
:3
P M
01-AE110
OVERALL FIRST FLOOR PLAN EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
NORTH
1/16" = 1'-0"1
OVERALL FIRST FLOOR PLAN 0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
FLOOR PLAN LEGEND
KEYED NOTES
09.48 TERMINATION POINT FOR NEW FINISHES
DN
DN UP
DN UP
DNUP
UP
DN
DN
PARTITION WALL
D WING
A WING
C WING
F WING
E WING
TR
01-AE320
01-AE321
01-AE320
TR
A R E A N
O T
IN
S C O P E
B WING
AA
D
A
D
A
A B
A
B B
B
B
C
C
C
E E
C
B D
D B
B E
B
E
F
F
F
F
C
C
E
E
B
2D02A-01
2D02-01
2A11-01 2C08-01
09.4709.47
09.47
09.47
09.47
09.47
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
2 HR. FIRE BARRIER
1 HR. FIRE BARRIER
SMOKE BARRIER
AREA OF CONSTRUCTION
EXISTING TELECOMMUNICATION SPACE
FIRE ALARM ZONE
WALL COVERING REMOVAL AND REPAIR
TR TELECOMMUNICATION ROOM
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/7
/2
:1
:3
P M
01-AE120
OVERALL SECOND FLOOR PLAN EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
NORTH
1/16" = 1'-0"1
OVERALL SECOND FLOOR PLAN
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
FLOOR PLAN LEGEND
KEYED NOTES
09.47 REPAIR WALL FINISH, SKIM COAT AND PAINT WHERE WALL COVERINGS HAVE BEEN
REMOVED
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
C H AS E
FD
FD
FD
FD
FD
FD
DN
UPDN
DN
UP
DNUP
D WING
A WING
C WING
TR
01-AE330
01-AE330
3 TR
B WING
A A
A
D
A
D
B D
D B
A B
A
B
C
C B
B C
C
B B
01-AE331
01-AE331
01-AE330
3A33-01
3A20-01
3A11B-01
3A11A-01
3A11C-01
3A08-01
3C08-01
3C08A-01
3C06-01
09.47
09.47
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
2 HR. FIRE BARRIER
1 HR. FIRE BARRIER
SMOKE BARRIER
AREA OF CONSTRUCTION
EXISTING TELECOMMUNICATION SPACE
FIRE ALARM ZONE
WALL COVERING REMOVAL AND REPAIR
TR TELECOMMUNICATION ROOM
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/7
/2
:1
:4
P M
01-AE130
OVERALL THIRD FLOOR PLAN EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
NORTH
1/16" = 1'-0"1
OVERALL THIRD FLOOR PLAN
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
FLOOR PLAN LEGEND
KEYED NOTES
09.47 REPAIR WALL FINISH, SKIM COAT AND PAINT WHERE WALL COVERINGS HAVE BEEN
UP
DN
DN
R O
O F
D WING
A WING
C WING
B WING
01-AE340
TR TR
01-AE340
B
B
B C
C B
B A
A
BA
D
A
D B
B
D
D
01-AE341
01-AE341
01-AE341
4C08-01 4A11B-01
4A11-01
4A11A-01
4A12-01
4A07-01
4A05A-01
09.4709.47 09.47
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
2 HR. FIRE BARRIER
1 HR. FIRE BARRIER
SMOKE BARRIER
AREA OF CONSTRUCTION
EXISTING TELECOMMUNICATION SPACE
FIRE ALARM ZONE
WALL COVERING REMOVAL AND REPAIR
TR TELECOMMUNICATION ROOM
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/7
/2
:1
:4
P M
01-AE140
OVERALL FOURTH FLOOR PLAN EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
NORTH
1/16" = 1'-0"1
OVERALL FOURTH FLOOR PLAN
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
FLOOR PLAN LEGEND
KEYED NOTES
09.47 REPAIR WALL FINISH, SKIM COAT AND PAINT WHERE WALL COVERINGS HAVE BEEN
DN UP
DN UP
01-AE350
TR
B WING
A D
A A B
A
B
D B
D
B
B C
C B
D WING
C WING
D
5B08A-01
09.47
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
2 HR. FIRE BARRIER
1 HR. FIRE BARRIER
SMOKE BARRIER
AREA OF CONSTRUCTION
EXISTING TELECOMMUNICATION SPACE
FIRE ALARM ZONE
WALL COVERING REMOVAL AND REPAIR
TR TELECOMMUNICATION ROOM
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/7
/2
:1
:4
P M
01-AE150
OVERALL FIFTH FLOOR PLAN EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
NORTH
1/16" = 1'-0"1
OVERALL FIFTH FLOOR PLAN
0' 8' 16' 32' 64'
GRAPHIC SCALE 1/16" = 1'-0"
4'
FLOOR PLAN LEGEND
KEYED NOTES
09.47 REPAIR WALL FINISH, SKIM COAT AND PAINT WHERE WALL COVERINGS HAVE BEEN
OS
F .E
.C
F.E.C.
2' x 4' LIGHT
ACT LAY-IN ACOUSTICAL
CEILING
EXISTING GYP. BD. CEILING
SUPPLY DIFFUSER
RETURN AIR
EXIT SIGN
EXISTING ACT LAY-IN ACOUSTICAL
CEILING
2' x 2' LIGHT
CEILING MOUNTED
MOTION SENSOR
GYP. BD. CEILING
EXHAUST FAN
RECESSED FIRE
SPRINKLER
WOOD PANEL CEILING
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
AUX. SYSTEMS
GC10A-01
5.65 ft²
SHOP PLUMBING
GC10CA-01
152.05 ft²
GC10C-01
E X
GC10CA-01
E X
153.05 ft²
HAC
GC10B-01
09.19
12'-4"
G C
B
-0
67.25 ft²
ENTRY
(UTILITIES)
GC10-01
GC10-01
10.02
10.02
11.06
09.18
10.02G-1
G-1
10.02
09.29
1,236.77 ft²
CORRIDOR
GC00-01
517.12 ft²
MECHANICAL
(PAINT SHOP)
GC10C-01
02.30
02.30
14.92 ft²
HAC
GC01A-01
135.37 ft²
TELECOMMUNICATIONS
ROOM
GC01-01
GC01-01
G C
A
-0
09.21
09.19
4'-5 1/2"
09.19
02.25
09.25
11.0111.01
21.03
10.02
10.02
11.06
G
H
C
D
09.28
09.19
09.38 09.38
1,236.77 ft²
CORRIDOR
GC00-01
C
01.19
02.30
08.11
137.34 ft²
TELECOMMUNICATIONS
ROOM
GA16-01
09.18
09.21
09.19
GA16-01
09.25
11.0111.01
21.0310.02
N
09.19
09.28
273.05 ft²
RELEASE OF
INFORMATION
GA18-01
3,400.43 ft²
CORRIDOR
GA00-01
09.03
09.01
09.01
CEILING ELEVATION AND GRID TO
ALIGN WITH EXISTING CORRIDOR
02.20
09.01
09.03
02.20
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/3
/2
:2
:5
P
M
01-AE300
ENLARGED GROUND FLOOR
PLANS
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
GRAPHIC SCALE 3/8" = 1'-0"
4'2'0" 1' 8'1'32"
REFLECTED CEILING PLAN LEGEND
NORTH
3/8" = 1'-0"1
GROUND FLOOR C-WING - HAC - GC10B-01 PLAN
NORTH
3/8" = 1'-0"2
GROUND FLOOR C-WING - TR - GC01-01 PLAN
NORTH
3/8" = 1'-0"3
GROUND FLOOR A-WING - TR - GA16-01 PLAN
NORTH
3/8" = 1'-0"5
GROUND FLOOR C-WING - TR - GC01-01 RCP
NORTH
3/8" = 1'-0"4
GROUND FLOOR C-WING - HAC - GC10-01 RCP
NORTH
3/8" = 1'-0"6
GROUND FLOOR A-WING - TR - GA15-01 RCP
KEYED NOTES
01.19 DO NOT INSTALL DATA RACKS OVER ACCESS HATCH. ENSURE ACCESS HATCH IS STILL
OPERABLE AND CLEAR OF ALL EQUIPMENT
02.20 EXISTING CEILING TO REMAIN
02.25 EXISTING MOP SINK TO REMAIN
02.30 EXISTING FLOOR ACCESS HATCH TO REMAIN
08.11 PROVIDE HARDWARE TO LOCK ACCESS HATCH FROM THE INTERIOR SIDE OF THE ROOM
09.01 ACOUSTICAL CEILING, SEE ROOM FINISH SCHEDULE
09.03 OPEN TO STRUCTURE ABOVE
09.18 INFILL WALL WITH NEW FRAMING AND 5/8" TYPE "X" GYPSUM WALL BOARD, FLUSH OUT
FINISHES TO MATCH EXISTING
09.19 ALIGN NEW WALL FINISH WITH EXISTING ADJACENT WALL FINISH
09.21 FOR BACKBOARD MATERIAL, FINISHES, AND LOCATION, PLEASE SEE
TELECOMMUNICATION SHEETS
09.25 ANTI-STATIC FLOORING IN ALL TELCOMMUNICATION ROOMS, SEE FINISH SCHEDULE
09.28 SECURE ROOM - EXTEND EXISTING ROOM BOUNDING WALL FRAMING AND A SINGLE
LAYER OF 5/8" TYPE "X" GYPSUM WALL BOARD FROM TOP OF WALL TO UNDERSIDE OF
DECK ABOVE, USE FASTENERS AND SCREW PATTERNS INDICATED IN WALL SECTIONS
09.29 1-HOUR RATED ROOM - ENSURE EXISTING ROOM BOUNDING WALLS EXTEND TO
UNDERSIDE OF DECK ABOVE. PATCH HOLES AND SEAL PENETRATIONS IN EXISTING
ROOM BOUNDING WALLS WITH 1-HOUR FIRE-RESISTIVE RATE SEALANT TO PROVIDE A
CONTINUOUS 1-HOUR FIRE RATED PERIMETER AROUND THE ROOM
09.38 8'-0" HIGH 3" STAINLESS STEEL CORNER GUARDS
10.02 LOCATION OF ROOM SIGNAGE
11.01 DATA RACK, SEE TELCOMMUNICATIONS DRAWINGS
11.06 UNLESS SPECIFICALLY CALLED OUT EQUIPMENT AND FURNISHINGS IN THIS ROOM ARE
SHOWN FOR COORDINATION AND SPACE PLANNING PURPOSES ONLY AND ARE NOT
INCLUDED IN THE PROJECT EQUIPMENT SCHEDULES
21.03 NEW RECESSED FIRE EXTINGUISHER CABINET WITH CLEAN AGENT A-B-C EXTINGUISHER
F.E.C.
2' x 4' LIGHT
ACT LAY-IN ACOUSTICAL
CEILING
EXISTING GYP. BD. CEILING
SUPPLY DIFFUSER
RETURN AIR
EXIT SIGN
EXISTING ACT LAY-IN ACOUSTICAL
CEILING
2' x 2' LIGHT
CEILING MOUNTED
MOTION SENSOR
GYP. BD. CEILING
EXHAUST FAN
RECESSED FIRE
SPRINKLER
WOOD PANEL CEILING
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
156.15 ft²
TELECOMMUNICATIONS
ROOM
1A15A-01
09.21
5' -8
/2
9'
-0
8'-3 1/2"
02.63
11.01
11.01
1A15A-01
21.03 10.02
09.28
1,486.06 ft²
CORRIDOR
1A00-01
09.03
179.11 ft²
CLEAN
UTILITY
1A04-01
1A
-0
01-AE401
CT020
C03F0 C03F0
CB020CB020
11.06
10.02
C01D0
09.29
1,486.06 ft²
CORRIDOR
1A00-01
09.48
09.4809.48
02.20
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/3
/2
:2
:5
P
M
01-AE310
ENLARGED FIRST FLOOR PLANS EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
GRAPHIC SCALE 3/8" = 1'-0"
4'2'0" 1' 8'1'32"
REFLECTED CEILING PLAN LEGEND
NORTH
3/8" = 1'-0"1
FIRST FLOOR A-WING - TR - 1A15A-01 PLAN
NORTH
3/8" = 1'-0"3
FIRST FLOOR A-WING - TR - 1A15A-01 RCP
KEYED NOTES
02.20 EXISTING CEILING TO REMAIN
02.63 REMOVE EXISTING FLOORING
09.03 OPEN TO STRUCTURE ABOVE
09.21 FOR BACKBOARD MATERIAL, FINISHES, AND LOCATION, PLEASE SEE
TELECOMMUNICATION SHEETS
09.28 SECURE ROOM - EXTEND EXISTING ROOM BOUNDING WALL FRAMING AND A SINGLE
LAYER OF 5/8" TYPE "X" GYPSUM WALL BOARD FROM TOP OF WALL TO UNDERSIDE OF
DECK ABOVE, USE FASTENERS AND SCREW PATTERNS INDICATED IN WALL SECTIONS
09.29 1-HOUR RATED ROOM - ENSURE EXISTING ROOM BOUNDING WALLS EXTEND TO
UNDERSIDE OF DECK ABOVE. PATCH HOLES AND SEAL PENETRATIONS IN EXISTING
ROOM BOUNDING WALLS WITH 1-HOUR FIRE-RESISTIVE RATE SEALANT TO PROVIDE A
CONTINUOUS 1-HOUR FIRE RATED PERIMETER AROUND THE ROOM
09.48 TERMINATION POINT FOR NEW FINISHES
10.02 LOCATION OF ROOM SIGNAGE
11.01 DATA RACK, SEE TELCOMMUNICATIONS DRAWINGS
11.06 UNLESS SPECIFICALLY CALLED OUT EQUIPMENT AND FURNISHINGS IN THIS ROOM ARE
SHOWN FOR COORDINATION AND SPACE PLANNING PURPOSES ONLY AND ARE NOT
INCLUDED IN THE PROJECT EQUIPMENT SCHEDULES
21.03 NEW RECESSED FIRE EXTINGUISHER CABINET WITH CLEAN AGENT A-B-C EXTINGUISHER
NORTH
3/8" = 1'-0"2
FIRST FLOOR A-WING - CLEAN UTILITY - 1A04-01 PLAN
NORTH
3/8" = 1'-0"4
FIRST FLOOR A-WING - CLEAN UTILITY - 1A04-01 RCP
F .E
.C
F.E.C.
2' x 4' LIGHT
ACT LAY-IN ACOUSTICAL
CEILING
EXISTING GYP. BD. CEILING
SUPPLY DIFFUSER
RETURN AIR
EXIT SIGN
EXISTING ACT LAY-IN ACOUSTICAL
CEILING
2' x 2' LIGHT
CEILING MOUNTED
MOTION SENSOR
GYP. BD. CEILING
EXHAUST FAN
RECESSED FIRE
SPRINKLER
WOOD PANEL CEILING
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
190.08 ft²
TELECOMMUNICATIONS
ROOM
1D42B-01
1D
B -0
09.21
09.25 11.0111.0111.01
21.03
10.02
09.18
09.18
C
D
09.28
09.18
09.42
463.99 ft²
ANGIOGRAPHY
1D42-01
852.32 ft²
CORRIDOR
1D00D-01
09.03
149.84 ft²
TELECOMMUNICATIONS
ROOM
1E02-01
210.99 ft²
WAITING
AREA
1E02A-01
1E02-01
09.21
09.25
11.01
11.01
21.0310.02
11.06
G
09.28
G
83.27 ft²
STORAGE
1C06-01
EX
08.09
09.18
5'-9" 10'-5"
09.18
1C06-01
10.02
1,478.34 ft²
CORRIDOR
1C00-01
02.20
09.03
09.01
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/3
/2
:2
:0
P
M
01-AE311
ENLARGED FIRST FLOOR PLANS EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
GRAPHIC SCALE 3/8" = 1'-0"
4'2'0" 1' 8'1'32"
REFLECTED CEILING PLAN LEGEND
KEYED NOTES
02.20 EXISTING CEILING TO REMAIN
08.09 INSTALL NEW TEMPERED SPANDREL GLASS IN EXISTING WINDOW FRAME TO MATCH
EXISTING WINDOW ASTHETICS AS CLOSELY AS POSSIBLE
09.01 ACOUSTICAL CEILING, SEE ROOM FINISH SCHEDULE
09.03 OPEN TO STRUCTURE ABOVE
09.18 INFILL WALL WITH NEW FRAMING AND 5/8" TYPE "X" GYPSUM WALL BOARD, FLUSH OUT
FINISHES TO MATCH EXISTING
09.21 FOR BACKBOARD MATERIAL, FINISHES, AND LOCATION, PLEASE SEE
TELECOMMUNICATION SHEETS
09.25 ANTI-STATIC FLOORING IN ALL TELCOMMUNICATION ROOMS, SEE FINISH SCHEDULE
09.28 SECURE ROOM - EXTEND EXISTING ROOM BOUNDING WALL FRAMING AND A SINGLE
LAYER OF 5/8" TYPE "X" GYPSUM WALL BOARD FROM TOP OF WALL TO UNDERSIDE OF
DECK ABOVE, USE FASTENERS AND SCREW PATTERNS INDICATED IN WALL SECTIONS
09.42 NEW VINYL CRASH RAIL TO MATCH AND ALIGN WITH EXISTING, MOUNTED
APPROXIMATELY 12"± AFF
10.02 LOCATION OF ROOM SIGNAGE
11.01 DATA RACK, SEE TELCOMMUNICATIONS DRAWINGS
11.06 UNLESS SPECIFICALLY CALLED OUT EQUIPMENT AND FURNISHINGS IN THIS ROOM ARE
SHOWN FOR COORDINATION AND SPACE PLANNING PURPOSES ONLY AND ARE NOT
INCLUDED IN THE PROJECT EQUIPMENT SCHEDULES
21.03 NEW RECESSED FIRE EXTINGUISHER CABINET WITH CLEAN AGENT A-B-C EXTINGUISHER
NORTH
3/8" = 1'-0"1
FIRST FLOOR D-WING - TR - 1D42B-01 PLAN
NORTH
3/8" = 1'-0"3
FIRST FLOOR D-WING - TR - 1D42B-01 RCP
NORTH
3/8" = 1'-0"2
FIRST FLOOR E-WING - TR - 1E02-01 PLAN
NORTH
3/8" = 1'-0"4
FIRST FLOOR E-WING - TR - 1E02-01 RCP
F.E.C. F.E.C.
2' x 4' LIGHT
ACT LAY-IN ACOUSTICAL
CEILING
EXISTING GYP. BD. CEILING
SUPPLY DIFFUSER
RETURN AIR
EXIT SIGN
EXISTING ACT LAY-IN ACOUSTICAL
CEILING
2' x 2' LIGHT
CEILING MOUNTED
MOTION SENSOR
GYP. BD. CEILING
EXHAUST FAN
RECESSED FIRE
SPRINKLER
WOOD PANEL CEILING
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
155.31 ft²
TELECOMMUNICATIONS
ROOM
2A11-01
122.66 ft²
WORKROOM
2A11A-01
2A11A-01
09.21
10'-4 1/2"
3/
4"
09.19
2A11-01
09.19
09.25
11.01
11.01
21.0310.02
11.06
10.02
J
K
R-2
C
09.28
09.31
09.18
09.33
09.39
09.41
09.39 09.39
150.40 ft²
TELECOMMUNICATIONS
ROOM
2C08-01
124.33 ft²
LOCKERS
2C08A-01
2C08A-01
09.21
10'-4 1/2"
09.25
11.01
11.01
2C08-01
21.03 10.0210.02
11.06
G
09.28
09.3909.39
1,603.80 ft²
CORRIDOR
2C00-01
09.16
02.20
09.03
02.2009.03
09.01
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/3
/2
:2
:0
P
M
01-AE320
ENLARGED SECOND FLOOR
PLANS
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
GRAPHIC SCALE 3/8" = 1'-0"
4'2'0" 1' 8'1'32"
REFLECTED CEILING PLAN LEGEND
NORTH
3/8" = 1'-0"2
SECOND FLOOR A-WING -TR - 2A11-01 PLAN
NORTH
3/8" = 1'-0"1
SECOND FLOOR C-WING - TR - 2C08-01 PLAN
NORTH
3/8" = 1'-0"3
SECOND FLOOR C-WING - TR - 2C08-01 RCP
NORTH
3/8" = 1'-0"4
SECOND FLOOR A-WING -TR - 2A11-01 RCP
KEYED NOTES
02.20 EXISTING CEILING TO REMAIN
09.01 ACOUSTICAL CEILING, SEE ROOM FINISH SCHEDULE
09.03 OPEN TO STRUCTURE ABOVE
09.16 PATCH AND REPAIR FLOORING WITH VA STOCK
09.18 INFILL WALL WITH NEW FRAMING AND 5/8" TYPE "X" GYPSUM WALL BOARD, FLUSH OUT
FINISHES TO MATCH EXISTING
09.19 ALIGN NEW WALL FINISH WITH EXISTING ADJACENT WALL FINISH
09.21 FOR BACKBOARD MATERIAL, FINISHES, AND LOCATION, PLEASE SEE
TELECOMMUNICATION SHEETS
09.25 ANTI-STATIC FLOORING IN ALL TELCOMMUNICATION ROOMS, SEE FINISH SCHEDULE
09.28 SECURE ROOM - EXTEND EXISTING ROOM BOUNDING WALL FRAMING AND A SINGLE
LAYER OF 5/8" TYPE "X" GYPSUM WALL BOARD FROM TOP OF WALL TO UNDERSIDE OF
DECK ABOVE, USE FASTENERS AND SCREW PATTERNS INDICATED IN WALL SECTIONS
09.31 INSTALL 3" GLASS FIBER SOUND ATTENUATION INSULATION (THERMAFIBER SAFB OR
EQUIVALENT) ABOVE CEILING AND ACROSS THE ENTIRE ROOM
09.33 REMOVE GYPSUM WALL BOARD ON EXISTING ROOM BOUNDING WALLS AND INSTALL 3"
GLASS FIBER SOUND ATTENUATION INSULATION (THERMAFIBER SAFB OR EQUIVALENT) IN
EXISTING WALL CAVITY TO A HEIGHT OF 4" ABOVE CEILING. INSTALL NEW 5/8" TYPE "X"
GYPSUM WALL BOARD AND SEAL WALL BOTTOM AND PENETRATIONS WITH ACOUSTICAL
SEALANT
09.39 NEW VINYL CRASH RAIL TO MATCH AND ALIGN WITH EXISTING, MOUNTED
APPROXIMATELY 31 1/2"± AFF
09.41 NEW VINYL CRASH RAIL TO MATCH AND ALIGN WITH EXISTING, MOUNTED
APPROXIMATELY 6"± AFF
10.02 LOCATION OF ROOM SIGNAGE
11.01 DATA RACK, SEE TELCOMMUNICATIONS DRAWINGS
11.06 UNLESS SPECIFICALLY CALLED OUT EQUIPMENT AND FURNISHINGS IN THIS ROOM ARE
SHOWN FOR COORDINATION AND SPACE PLANNING PURPOSES ONLY AND ARE NOT
INCLUDED IN THE PROJECT EQUIPMENT SCHEDULES
2' x 4' LIGHT
ACT LAY-IN ACOUSTICAL
CEILING
EXISTING GYP. BD. CEILING
SUPPLY DIFFUSER
RETURN AIR
EXIT SIGN
EXISTING ACT LAY-IN ACOUSTICAL
CEILING
2' x 2' LIGHT
CEILING MOUNTED
MOTION SENSOR
GYP. BD. CEILING
EXHAUST FAN
RECESSED FIRE
SPRINKLER
WOOD PANEL CEILING
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
386.62 ft²
WAITING
AREA
2D02-01
300.13 ft²
LOCKER/LOUNGE
2D02A-01
EX
E X
E X
E X
EX
EX
E X
09.18
01-AE400
02.24
01-AE400
F0225
A1030
A1030
A1030
A1030
A1030
A1030
R7250 R7250
F2015
CB020 K4665
CB020 CB020
K1552
CB020
CT020
A5075
A5080
F0795
F0225
F0225F0225
F0225
F0225F0795
F0225
F0225
A5210A5220
F3025
F3050
CS010
F3200
C04P0
C02C0
C02D0
A1080
F0305 F0305 F0305 F0740
F0206
F0305F0305F0305
F0740 F0305
A5210
F0305 M0515
F3200
F2300
02.09
A6030
A6030
CT020
A5220
10.02K
H
09.32
09.50
09.50
09.38
09.38
09.38
A6046
A6046
TEAM ROOM
3A33-01
TOILET PATIENT
2D24A-01
UNISEX
2D04-01
ELECTRICAL
2D03-01
E X
E X
09.48
09.50
09.48
EX
EX
EX
EX
D
02.20
09.01
09.01
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/7
/2
:1
:4
P M
01-AE321
ENLARGED SECOND FLOOR
PLANS
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
GRAPHIC SCALE 3/8" = 1'-0"
4'2'0" 1' 8'1'32"
REFLECTED CEILING PLAN LEGEND
NORTH
3/8" = 1'-0"1
SECOND FLOOR D-WING - LOCKER/LOUNGE - 2D02A-01 PLAN
NORTH
3/8" = 1'-0"2
SECOND FLOOR D-WING - LOCKER/LOUNGE - 2D02A-01 RCP
KEYED NOTES
02.09 EXISTING DRINKING FOUNTAIN TO REMAIN
02.20 EXISTING CEILING TO REMAIN
02.24 EXISTING FIRE EXTINGUISHER CABINET TO REMAIN
09.01 ACOUSTICAL CEILING, SEE ROOM FINISH SCHEDULE
09.18 INFILL WALL WITH NEW FRAMING AND 5/8" TYPE "X" GYPSUM WALL BOARD, FLUSH OUT
FINISHES TO MATCH EXISTING
09.32 INSTALL A 4'-0" STRIP OF 3" GLASS FIBER SOUND ATTENUATION INSULATION
(THERMAFIBER SAFB OR EQUIVALENT) ABOVE CEILING AND PARALLEL TO WALL TYPE K
FOR THE ENTIRE LENGTH OF THE ROOM
09.38 8'-0" HIGH 3" STAINLESS STEEL CORNER GUARDS
09.48 TERMINATION POINT FOR NEW FINISHES
09.50 8'-0" HIGH 2" STAINLESS STEEL CORNER GUARDS
10.02 LOCATION OF ROOM SIGNAGE
F .E
.C
2' x 4' LIGHT
ACT LAY-IN ACOUSTICAL
CEILING
EXISTING GYP. BD. CEILING
SUPPLY DIFFUSER
RETURN AIR
EXIT SIGN
EXISTING ACT LAY-IN ACOUSTICAL
CEILING
2' x 2' LIGHT
CEILING MOUNTED
MOTION SENSOR
GYP. BD. CEILING
EXHAUST FAN
RECESSED FIRE
SPRINKLER
WOOD PANEL CEILING
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
120.00 ft²
TELECOMMUNICATIONS
ROOM
3A11B-01
97.26 ft²
CLEAN ROOM
3A11C-01
3A11C-01
09.21
12'-4 1/2"
09.19
3A11B-01
1/
2"
79.32 ft²
ALCOVE
3A11A-01 5'
-9
09.19
09.25
11.0111.01
21.03
11.06
10.02
10.02
D G
G-1 G-1
R-2
C
09.28
09.29
09.41
09.41
09.41
09.3909.38 09.38
09.38
09.48
1,445.87 ft²
CORRIDOR
3A00-01
130.20 ft²
TELECOMMUNICATIONS
ROOM
3C08A-01
180.16 ft²
PROCEDURE
3C08-01
3C08A-01
11.01
11.01
3C08-01
180.16 ft²
PROCEDURE
3C06-01
3C06-01
01-AE401
12'-5" 10'-5" 12'-1 1/2"
09.21
09.25
F0205 E0915
M4255
E0948
A5107
F3010
F2000
F3200
A5180
CS010
A5080
A5075
A5108
A1011
CE040
M1801E0945
M7401
M3070 M3072
M4100
M0765
M0750
M8810
F3200
F2000
E0948
M7710 F0205
F3010 F0340
E0915
M3072 M3070
CT020
A5180
CT020
C02Q0 A5108
CE040
A1011
E0945M1801
M4116
M7401
A5107
M4255 M0750
M8810
A1200
A5075
A5080
M0765
M4100
M4200
M0765
C02Q0
M7710
M4116
F0340
A1200
M4200
A1132M4655M4655
C02Q0
M0755 M0755
21.03
10.02
10.02
EX
J
C G
J
E J
EX
09.19 09.19
09.28
09.1809.30 09.38 09.3809.3909.39
2'-10" 2'-10"
09.39
3,931.42 ft²
CORRIDOR
3C00-01
09.48
02.20
09.03
02.20
09.23
09.03
09.01
09.01
09.23
161.25 ft²
CLEAN LINEN
ROOM
3A08-01
EX
OFFICE
3A10A-01
09.16
1,445.87 ft²
CORRIDOR
3A00-01
09.01
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/3
/2
:2
:1
P
M
01-AE330
ENLARGED THIRD FLOOR PLANS EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
GRAPHIC SCALE 3/8" = 1'-0"
4'2'0" 1' 8'1'32"
REFLECTED CEILING PLAN LEGEND
NORTH
3/8" = 1'-0"1
THIRD FLOOR A-WING - TR - 3A11B-01 PLAN
NORTH
3/8" = 1'-0"3
THIRD FLOOR C-WING - TR - 3C08A-01 PLAN
NORTH
3/8" = 1'-0"6
THIRD FLOOR C-WING - TR - 3C08A-01 RCP
NORTH
3/8" = 1'-0"4
THIRD FLOOR A-WING - TR - 3A11B-01 RCP
KEYED NOTES
02.20 EXISTING CEILING TO REMAIN
09.01 ACOUSTICAL CEILING, SEE ROOM FINISH SCHEDULE
09.03 OPEN TO STRUCTURE ABOVE
09.16 PATCH AND REPAIR FLOORING WITH VA STOCK
09.18 INFILL WALL WITH NEW FRAMING AND 5/8" TYPE "X" GYPSUM WALL BOARD, FLUSH OUT
FINISHES TO MATCH EXISTING
09.19 ALIGN NEW WALL FINISH WITH EXISTING ADJACENT WALL FINISH
09.21 FOR BACKBOARD MATERIAL, FINISHES, AND LOCATION, PLEASE SEE
TELECOMMUNICATION SHEETS
09.23 GYPSUM BOARD SOFFIT, SEE ROOM FINISH LEGEND
09.25 ANTI-STATIC FLOORING IN ALL TELCOMMUNICATION ROOMS, SEE FINISH SCHEDULE
09.28 SECURE ROOM - EXTEND EXISTING ROOM BOUNDING WALL FRAMING AND A SINGLE
LAYER OF 5/8" TYPE "X" GYPSUM WALL BOARD FROM TOP OF WALL TO UNDERSIDE OF
DECK ABOVE, USE FASTENERS AND SCREW PATTERNS INDICATED IN WALL SECTIONS
09.29 1-HOUR RATED ROOM - ENSURE EXISTING ROOM BOUNDING WALLS EXTEND TO
UNDERSIDE OF DECK ABOVE. PATCH HOLES AND SEAL PENETRATIONS IN EXISTING
ROOM BOUNDING WALLS WITH 1-HOUR FIRE-RESISTIVE RATE SEALANT TO PROVIDE A
CONTINUOUS 1-HOUR FIRE RATED PERIMETER AROUND THE ROOM
09.30 PROVIDE 3" GLASS FIBER SOUND ATTENUATION INSULATION (THERMAFIBER SAFB OR
EQUIVALENT) AT WALL INFILL
09.38 8'-0" HIGH 3" STAINLESS STEEL CORNER GUARDS
09.39 NEW VINYL CRASH RAIL TO MATCH AND ALIGN WITH EXISTING, MOUNTED
APPROXIMATELY 31 1/2"± AFF
09.41 NEW VINYL CRASH RAIL TO MATCH AND ALIGN WITH EXISTING, MOUNTED
APPROXIMATELY 6"± AFF
09.48 TERMINATION POINT FOR NEW FINISHES
10.02 LOCATION OF ROOM SIGNAGE
11.01 DATA RACK, SEE TELCOMMUNICATIONS DRAWINGS
11.06 UNLESS SPECIFICALLY CALLED OUT EQUIPMENT AND FURNISHINGS IN THIS ROOM ARE
SHOWN FOR COORDINATION AND SPACE PLANNING PURPOSES ONLY AND ARE NOT
INCLUDED IN THE PROJECT EQUIPMENT SCHEDULES
21.03 NEW RECESSED FIRE EXTINGUISHER CABINET WITH CLEAN AGENT A-B-C EXTINGUISHER
NORTH
3/8" = 1'-0"2
THIRD FLOOR A-WING - CLEAN LINEN - 3A08-01 PLAN
NORTH
3/8" = 1'-0"5
THIRD FLOOR A-WING - CLEAN LINEN - 3A08-01 RCP
CHASE
2' x 4' LIGHT
ACT LAY-IN ACOUSTICAL
CEILING
EXISTING GYP. BD. CEILING
SUPPLY DIFFUSER
RETURN AIR
EXIT SIGN
EXISTING ACT LAY-IN ACOUSTICAL
CEILING
2' x 2' LIGHT
CEILING MOUNTED
MOTION SENSOR
GYP. BD. CEILING
EXHAUST FAN
RECESSED FIRE
SPRINKLER
WOOD PANEL CEILING
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
09.01
199.88 ft²
TEAM ROOM
3A33-01
09.1809.30
EX
EX
E X
47.49 ft²
TOILET
(PATIENT)
3A31A-01
551.89 ft²
CORRIDOR
3A00B-01
09.01
09.18
195.67 ft²
TEAM ROOM
3A20-01
3A
-0
10.02
11.06
A
09.18
09.30
09.30
09.31
09.33
09.39
551.89 ft²
CORRIDOR
3A00B-01
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/3
/2
:2
:1
P
M
01-AE331
ENLARGED THIRD FLOOR PLANS EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023
06/08/23
REFLECTED CEILING PLAN LEGEND
KEYED NOTES
09.01 ACOUSTICAL CEILING, SEE ROOM FINISH SCHEDULE
09.18 INFILL WALL WITH NEW FRAMING AND 5/8" TYPE "X" GYPSUM WALL BOARD, FLUSH OUT
FINISHES TO MATCH EXISTING
09.30 PROVIDE 3" GLASS FIBER SOUND ATTENUATION INSULATION (THERMAFIBER SAFB OR
EQUIVALENT) AT WALL INFILL
09.31 INSTALL 3" GLASS FIBER SOUND ATTENUATION INSULATION (THERMAFIBER SAFB OR
EQUIVALENT) ABOVE CEILING AND ACROSS THE ENTIRE ROOM
09.33 REMOVE GYPSUM WALL BOARD ON EXISTING ROOM BOUNDING WALLS AND INSTALL 3"
GLASS FIBER SOUND ATTENUATION INSULATION (THERMAFIBER SAFB OR EQUIVALENT) IN
EXISTING WALL CAVITY TO A HEIGHT OF 4" ABOVE CEILING. INSTALL NEW 5/8" TYPE "X"
GYPSUM WALL BOARD AND SEAL WALL BOTTOM AND PENETRATIONS WITH ACOUSTICAL
SEALANT
09.39 NEW VINYL CRASH RAIL TO MATCH AND ALIGN WITH EXISTING, MOUNTED
APPROXIMATELY 31 1/2"± AFF
10.02 LOCATION OF ROOM SIGNAGE
11.06 UNLESS SPECIFICALLY CALLED OUT EQUIPMENT AND FURNISHINGS IN THIS ROOM ARE
SHOWN FOR COORDINATION AND SPACE PLANNING PURPOSES ONLY AND ARE NOT
INCLUDED IN THE PROJECT EQUIPMENT SCHEDULES
NORTH
3/8" = 1'-0"3
THIRD FLOOR A-WING - TEAM ROOM - 3A33-01 RCP
NORTH
3/8" = 1'-0"1
THIRD FLOOR A-WING - TEAM ROOM - 3A33-01 PLAN
NORTH
3/8" = 1'-0"4
THIRD FLOOR A-WING - TEAM ROOM - 3A20-01 RCP
NORTH
3/8" = 1'-0"2
THIRD FLOOR A-WING - TEAM RM - 3A20-01 PLAN
F.E.C.
2' x 4' LIGHT
ACT LAY-IN ACOUSTICAL
CEILING
EXISTING GYP. BD. CEILING
SUPPLY DIFFUSER
RETURN AIR
EXIT SIGN
EXISTING ACT LAY-IN ACOUSTICAL
CEILING
2' x 2' LIGHT
CEILING MOUNTED
MOTION SENSOR
GYP. BD. CEILING
EXHAUST FAN
RECESSED FIRE
SPRINKLER
WOOD PANEL CEILING
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN
EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION,
UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. FOR FINISHES SEE FINISH SCHEDULE ON SHEET 01-AE601.
5. THE CONTRACTOR IS RESPONSIBLE FOR SEALING ANY PENETRATIONS THEY MAKE IN
EXISTING FIRE RESISTIVE RATED WALLS AND OR SMOKE WALLS WITH THE
APPROPRIATE SEALANT TO MAINTAIN THE INDICATED FIRE RESISTIVE RATING.
6. NEW SOFFITS TO BE 6" BELOW ADJACENT CEILING U.N.O.
120.00 ft²
TELECOMMUNICATIONS
ROOM
4A11A-01
121.07 ft²
VITALS
ROOM
4A11B-01
4A11A-01
09.21
10'-4 1/2"
09.19
09.19
09.25 11.01
11.01
'-0
/2
A5107
43.93 ft²
ALCOVE
4A11-01
4A
B -0
F2000
F0275
M4020
F0206
M4116
M1801 E0945
M7040
21.03
10.02
10.02
11.06
K
K
KGD
C
R-2
4"
09.19
J
09.31
09.28
09.33
09.39
09.41
09.41
09.41
09.41
09.3809.38 09.38
110.74 ft²
CORRIDOR
4A00A-01
09.48
197.61 ft²
TELECOMMUNICATIONS
ROOM
4C08-01
09.21
09.18
09.25
11.01
11.01
4C08-01
21.0310.01
08.09
EX
09.28
09.2009.20
3,497.14 ft²
CORRIDOR
4B00-01
02.20
09.03
09.01
09.01
09.23
09.03
RAND M.
EARDLEY
128806
S T
OF
A T
E UTA
H
ARED CH
IT
E C T
N S
C E
L I
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SHEET TO BE VIEWED AND PRINTED IN COLOR
A u to d e s k D o c s /2
S
L C
V A
M C
E H
R M
I n fr a s tr u c tu re U p g ra d e s /B ld g
A
R C
H .r v t
/3
/2
:2
:1
P
M
01-AE340
ENLARGED FOURTH FLOOR
PLANS
EHRM INFRASTRUCTURE
UPGRADES
SALT LAKE CITY, UT 84148
660-21-700
BUILDING 01
08 JUN 2023 PURCELL ROOKER
06/08/23
GRAPHIC SCALE 3/8" = 1'-0"
4'2'0" 1' 8'1'32"
REFLECTED CEILING PLAN LEGEND
NORTH
3/8" = 1'-0"1
FOURTH FLOOR A-WING - TR/VITALS ROOM - 4A11A-01 PLAN
NORTH
3/8" = 1'-0"2
FOURTH FLOOR C-WING - TR - 4C08-01 PLAN
NORTH
3/8" = 1'-0"3
FOURTH FLOOR A-WING - TR/TRIAGE ROOM - 4A11A-01 RCP
NORTH
3/8" = 1'-0"4
FOURTH FLOOR C-WING - TR - 4C08-01 RCP
KEYED NOTES
02.20 EXISTING CEILING TO REMAIN
08.09 INSTALL NEW TEMPERED SPANDREL GLASS IN EXISTING WINDOW FRAME TO MATCH
EXISTING WINDOW ASTHETICS AS CLOSELY AS POSSIBLE
09.01 ACOUSTICAL CEILING, SEE ROOM FINISH SCHEDULE
09.03 OPEN TO STRUCTURE ABOVE
09.18 INFILL WALL WITH NEW FRAMING AND 5/8" TYPE "X" GYPSUM WALL BOARD, FLUSH OUT
FINISHES TO MATCH EXISTING
09.19 ALIGN NEW WALL FINISH WITH EXISTING ADJACENT WALL FINISH
09.20 PATCH AND REPAIR GYPSUM WALL BOARD WHERE WALL TILE WAS REMOVED
09.21 FOR BACKBOARD MATERIAL, FINISHES, AND LOCATION, PLEASE SEE
TELECOMMUNICATION SHEETS
09.23 GYPSUM BOARD SOFFIT, SEE ROOM FINISH LEGEND
09.25 ANTI-STATIC FLOORING IN ALL TELCOMMUNICATION ROOMS, SEE FINISH SCHEDULE
09.28 SECURE ROOM - EXTEND EXISTING ROOM BOUNDING WALL FRAMING AND A SINGLE
LAYER OF 5/8" TYPE "X" GYPSUM WALL BOARD FROM TOP OF WALL TO UNDERSIDE OF
DECK ABOVE, USE FASTENERS AND SCREW PATTERNS INDICATED IN WALL SECTIONS
09.31 INSTALL 3" GLASS FIBER SOUND ATTENUATION INSULATION (THERMAFIBER SAFB OR
EQUIVALENT) ABOVE CEILING AND ACROSS THE ENTIRE ROOM
09.33 REMOVE GYPSUM WALL BOARD ON EXISTING ROOM BOUNDING WALLS AND INSTALL 3"
GLASS FIBER SOUND ATTENUATION INSULATION…