Attachment 14 - DWG - 10 - T.pdf
PDF 6 MB Posted
- Attached to
- Y1DA--626-310 Construct Sleep Disorder Clinic and Specialty Clinics Minor Construction - Murfreesboro
- Solicitation number
- 36C77625B0035
About this file
This document is a set of technology-related architectural drawings for a VA Sleep Disorder Clinic and Specialty Clinic project located in Murfreesboro, Tennessee. The drawings provide detailed technical specifications for technology infrastructure, including floor plans, riser diagrams, and installation details for various technology systems such as:
Key technology systems include wireless access points, security systems (card readers, electric strikes, cameras), audio-visual equipment, telecommunications infrastructure, data and fiber optic cabling, ground bars, rack elevations, and power distribution. The drawings cover multiple floor levels (basement, first, and second floors) and specify precise installation requirements for technology outlets, conduits, cable management, and networking equipment. The technical drawings are part of the construction documents for a fully sprinkled facility, with detailed notes on cable routing, mounting heights, and coordination requirements with electrical and architectural plans.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BASIC MATERIALS
CONDUIT TURNED UP
CONDUIT TURNED DOWN
CAPPED CONDUIT
CONDUIT STUBBED AND BUSHED INTO ACCESSIBLE CEILING CAVITY
CONDUIT CONTINUED
TUBULAR RUNWAY, HUNG ABOVE CEILING OR AS NOTED
CABLE TRAY (TYPE), HUNG ABOVE CEILING OR AS NOTED
VOICE AND DATA SYSTEM
DISTRIBUTED ANTENNA SYSTEMS
DAS REPEATERRP
TECHNOLOGY SYSTEMS GENERAL NOTES
1. REFER TO SPECIFICATION SECTION "TECHNOLOGY GENERAL PROVISIONS" FOR MORE INFORMATION ABOUT DRAWINGS AND BID DOCUMENTS.
2. MANY SYMBOLS USED IN THIS PROJECT HAVE A TYPE ASSOCIATED WITH THEM. SEE SHEETS WITH DETAILS AND PROJECT SPECIFICATIONS FOR MORE
INFORMATION ON THE DESCRIPTION OF EACH TYPE.
3. ALL CONDUIT FOR TECHNOLOGY SYSTEMS INDOOR ABOVE GRADE SHALL BE EMT AND ALL CONDUIT FOR BELOW GRADE SHALL BE PVC.
4. SEE LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED PARTITIONS IN THIS PROJECT. PROVIDE AN APPROVED FIRE STOP SYSTEMS FOR EACH RACEWAY OR CABLE GOING THROUGH A RATED WALL. SEE SPECIFICATION "RACEWAYS FOR TECHNOLOGY" FOR MORE INFORMATION.
5. WORKING CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL BE MAINTAINED IN COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE ARTICLE 110.
COORDINATE EQUIPMENT INSTALLATION TO MAINTAIN REQUIRED CLEARANCES.
6. SYMBOLS USED ON THE TECHNOLOGY DRAWINGS ARE NOT THE SAME SIZE AS THE ACTUAL OBJECT BEING REPRESENTED. THEREFORE LOCATIONS OF THE SYMBOLS ON THE FLOOR PLANS ARE AN APPROXIMATION TO THE ACTUAL LOCATION OF THE DEVICE AND NEED TO BE CAREFULLY COORDINATED
WITH OTHER ELEMENTS IN THE VICINITY. AS A GENERAL GUIDELINE:
A. VOICE/DATA OUTLET FOR WORK-AREAS SHALL BE INSTALLED WITHIN 6 INCHES OF A POWER OUTLET INDICATED IN ELECTRICAL DRAWINGS.
B. TV OUTLETS SHALL BE INSTALLED WITHIN 6 INCHES OF A POWER OUTLET SHOWN ON THE ELECTRICAL DRAWINGS.
C. WHEN MULTIPLE TECHNOLOGY SYSTEMS OUTLETS ARE INDICATED NEXT TO EACH OTHER WITH SYMBOLS, THE SPACING BETWEEN OUTLETS SHALL BE
CONSISTENT IF NO ELEVATION IS SHOWN ON THE DRAWINGS.
D. WHEN INSTALLER IS NOT CERTAIN ABOUT SPECIFIC ADJACENCIES OF A DEVICE, THE QUESTION SHALL BE ASKED TO THE ENGINEER PRIOR TO
INSTALLATION.
7. FOR EXACT LOCATION OF CEILING MOUNTED EQUIPMENT REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN. LOCATIONS OF EQUIPMENT NOT INCLUDED ON THE REFLECTED CEILING PLAN SHALL BE COORDINATED WITH THOSE ITEMS SHOWN. COORDINATION OF CEILING MOUNTED EQUIPMENT
SHALL BE PRIOR TO ANY ROUGH-IN. NOTIFY ENGINEER OF ANY DISCREPANCY.
8. LOCATIONS OF FLOOR BOXES AND FLOOR PENETRATIONS SHALL NOT BE MEASURED FROM THIS SET OF DRAWINGS, INSTALLER SHALL REQUEST PRECISE
LOCATIONS FROM ARCHITECT.
9. EACH VOICE/DATA RJ45 JACK SHALL BE CONNECTED TO A DEDICATED 4 PR CABLE.
10. THE RESPONSIBILITY OF RACEWAY INSTALLATION SHALL BE AS DIRECTED BY THE CONSTRUCTION MANAGER OR GENERAL CONTRACTOR, BUT ALL
RACEWAYS FOR TECHNOLOGY ARE TO BE INCLUDED IN THIS CONTRACT.
11. WHEN CONDUIT RUNS ARE INDICATED ABOVE GRADE OR BELOW GRADE ON THESE DRAWINGS, NOT EVERY SINGLE JUNCTION BOX (OR COMMUNICATIONS VAULT) REQUIRED IS INDICATED ON THE DRAWINGS. TYPICALLY ONLY END POINT LOCATIONS OR SPECIFIC PASS-THROUGH LOCATIONS WHERE THE ENGINEER DESIRES A BOX ARE SHOWN ON THE DRAWINGS. SEE SPECIFICATION "RACEWAYS FOR TECHNOLOGY" FOR REQUIREMENTS THAT INDICATE ADDITIONAL JUNCTION BOXES OR COMMUNICATION VAULTS THAT SHALL BE PROVIDED UNDER THIS CONTRACT. SUCH REQUIREMENTS INCLUDE ADDITIONAL BOXES REQUIRED BECAUSE OF NUMBER OF CONDUIT BENDS OR CHANGES IN ELEVATION.
12. SOME SYMBOLS INCLUDED IN THE SYMBOL LEGEND MAY NOT BE USED IN THESE PROJECT DRAWINGS.
13. UNDER NO CONDITIONS, CONDUITS FOR LOW VOLTAGE FOR FLOOR BOXES SHALL BE DAISY CHAINED TOGETHER BETWEEN ADJACENT FLOOR BOXES.
ALL CONDUITS FOR FLOOR BOXES SHALL BE HOME RUNS TO NEAREST ACCESSIBLE CEILING SPACE.
14. THIS SET OF DRAWINGS DOES NOT INDICATE ALL GROUNDING AND BONDING REQUIREMENTS FOR TECHNOLOGY SYSTEMS. REFER TO SPECIFICATION
SECTION "GROUNDING FOR TELECOMMUNICATION SYSTEM" FOR ADDITIONAL REQUIREMENTS.
15. ALL CABLES FOR TECHNOLOGY SYSTEMS RUN UNDER SLAB OR BELOW GRADE IN CONDUITS STUBBING UP INSIDE THE TELECOM ROOM SHALL BE INDOOR/OUTDOOR RATED. FOR CONDUITS STUBBING UP IN OTHER LOCATIONS DIFFERENT FROM TELECOM ROOMS AND FURTHER THAN 50 FT. FROM A
TELECOM ROOM, DO NOT USE INDOOR/OUTDOOR RATED CABLES.
16. GRAPHICS USED FOR EQUIPMENT IN ELEVATIONS AND CHANNELS (LINE DRAWINGS) DO NOT NECESSARILY REPRESENT THE PART NUMBER OF THE EQUIPMENT SPECIFIED. THE PART NUMBERS LISTED IN THE DRAWINGS AND SPECIFICATIONS ARE TO BE FOLLOWED FOR BASIS OF DESIGN, NOT THE
GRAPHICS.
17. THE TECHNOLOGY DRAWINGS DO NOT SHOW ALL REQUIRED CONDUITS/RACEWAYS TO BE PROVIDED UNDER THIS CONTRACT. TYPICALLY CONDUIT SLEEVES SMALLER THAN 2" ARE NOT SHOWN ON THE DRAWINGS. SEE SPECIFICATIONS "RACEWAYS FOR TECHNOLOGY" AND DRAWING DETAILS FOR
ADDITIONAL RACEWAY REQUIREMENTS.
18. DEFINITION OF ACRONYMS USED IN THESE DRAWINGS:
A. NIC (N.I.C.) - NOT IN CONTRACT
B. OFE (O.F.E.) = OWNER FURNISHED EQUIPMENT. SEE RESPONSIBILITY MATRIX FOR MORE INFORMATION.
C. DHI (D.H.I.) = DOOR HARDWARE INSTALLER
D. USC (U.S.C.) = UNDER SEPARATE CONTRACT.
19. ALL REQUIRED WALL PENETRATIONS, EXISTING AND NEW, SHALL MAINTAIN THE NEW WALL RATING AFTER CABLING HAS BEEN INSTALLED OR REMOVED.
20. ALL SPEAKERS MOUNTED IN A CEILING TILE SHALL BE CENTERED IN THE CEILING TILE.
1. SYMBOLS USED TO REPRESENT DEVICES SUCH AS CCTV CAMERAS, INTERCOM STATIONS, SECURITY WORKSTATIONS, CALL STATIONS, AND EMERGENCY PHONE STATIONS REQUIRE ONE (1) DATA DROP FOR SUCH DEVICE. THIS DATA DROP IS NOT SHOWN ON THE VOICE/DATA FLOOR PLANS, BUT SHALL BE PROVIDED FOLLOWING ALL REQUIREMENTS FOR VOICE/DATA DROPS INDICATED IN THE DRAWING DETAILS AND IN THE SPECIFICATION "STRUCTURED
CABLING SYSTEM".
2. ANY DATA DROPS FOR SECURITY DEVICES EXCEEDING 295 FT. OF PERMANENT LINK DISTANCE TO THE TELECOM ROOM WHERE CAMERA WILL BE WIRED TO, SHALL BE WIRED WITH FIBER OPTICS FOR HORIZONTAL CABLING AND A 2 CONDUCTOR AWG-16 CL2(P) CABLE. THE FIBER CABLE SHALL BE AS DESCRIBED IN SPECIFICATION "STRUCTURED CABLING SYSTEM". IF NO INDICATION IN SUCH SPECIFICATION, FIBER OPTIC CABLE SHALL BE A 2-STRAND OM1
CABLE WITH A SUITABLE JACKET FOR THE APPLICATION.
3. ALL DOUBLE DOORS THAT ARE SHOWN WITH TWO DOOR POSITIONS SWITCHES ARE TO RECEIVE (1) DOOR POSITION SWITCH ON EACH DOOR LEAF AND
SHALL REPORT AS ONE ALARM POINT.
4. ALL CAMERAS, CARD READERS AND/OR KEYPADS DEDICATED FOR ELEVATOR FLOOR SELECTION CONTROL ARE SHOWN INSIDE THE ELEVATOR CAB ON THE
LOWEST LEVEL FLOOR PLAN TO WHICH THE ELEVATOR TRAVELS.
5. LOCATION OF SURVEILLANCE CAMERAS SHALL BE CLOSELY COORDINATED WITH OTHER TRADES TO AVOID OBSTRUCTIONS IN THE FIELD OF VIEW. IT IS NOT REQUIRED FOR CAMERAS TO BE MOUNTED IN CENTER OF A CEILING TILE (OR CENTER OF A HALLWAY) IF THAT LOCATION CAUSES AN OBSTRUCTION IN THE FIELD OF VIEW OF THE CAMERA. ALL CAMERAS ARE TO BE INSTALLED AS TO MINIMIZE THE OBSTRUCTIONS IN THE FIELD OF VIEW WITHIN A 4' RADIUS
OF THE SPECIFIED LOCATION.
6. SURVEILLANCE CAMERAS INDICATED IN THE CORNER OF A ROOM SHALL BE INSTALLED AS CLOSE AS PHYSICALLY POSSIBLE TO THE CORNER OF THE ROOM
TO GAIN THE BEST FIELD OF VIEW FOR THAT CAMERA.
7. EACH ACCESS CONTROLLED DOOR IN THE PROJECT HAS A DOOR IDENTIFIER SYMBOL THAT ASSOCIATES THE DOOR TO A CORRESPONDING ROUGH-IN DETAIL IN THE DRAWINGS AND A SPECIFIC FUNCTIONALITY OF THE DOOR IN THE SECURITY SPECIFICATIONS.
SECURITY SYSTEM GENERAL NOTES
CONDUIT SLEEVES
X= QTY OF SLEEVES
Y= SIZE OF CONDUITS SLEEVES PENETRATING WALL ABOVE CEILING SPACE.
IF NO QUANTITY INDICATED USE AS MANY SLEEVES AS REQUIRED TO MATCH CROSS
SECTIONAL AREA OF CABLE TRAY NEXT TO SLEEVE.
X Y
SURFACE MOUNTED ENCLOSED TECHNOLOGY SYSTEMS. SEE SHEETS WITH DETAILS FOR
ADDITIONAL INFORMATION
CABLE ROUTING NOTESX
DRAWING KEYED NOTESX
DRAWING NOTES AND DESIGNATIONS
XXX
DOOR TYPE IDENTIFIER
X= TYPE (A1,C3,B6..) REFER TO SECURITY DOOR DETAILS
DETAIL OR SECTION REFERENCE TAG
X
X
GENERAL
JUNCTION BOX WALL MOUNTED. SIZE PER NEC IF NOT INDICATED ON DRAWING. NEMA 1 FOR
INTERIOR, NEMA 4X FOR EXTERIOR USE WITH HINGED COVER AND LOCKING COVER
J
JUNCTION BOX CEILING MOUNTED. SIZE PER NEC IF NOT INDICATED ON DRAWING. NEMA 1 FOR
INTERIOR, NEMA 4X FOR EXTERIOR USE WITH HINGED COVER AND LOCKING COVER
J
X V
TELECOMMUNICATIONS GROUND VAULT. SEE DETAILS AND SPECS FOR MORE INFORMATION
X= BOX TYPE. IF NOT SHOWN, ONLY ONE TYPE IN PROJECT
X
PP
POWER POLE FOR COMBINED USE - TECHNOLOGY SYSTEMS AND POWER.
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT
NURSE CALL SYSTEMS
SINGLE PATIENT STATION, WALL MOUNTEDN1
DUAL PATIENT STATION, WALL MOUNTEDN2
DUTY STATION, WALL MOUNTEDD
STAFF ASSIST STATION, WALL MOUNTEDS
CODE BLUE/STAFF ASSIST STATION, WALL MOUNTEDCA
STAFF ASSIST STATION, WALL MOUNTEDSA
TOILET STATION, WALL MOUNTEDT
SHOWER PULL STATION, WALL MOUNTEDSH
CODE BLUE STATION, WALL MOUNTEDCB
CORRIDOR DOME LIGHT, WALL MOUNTEDC
CORRIDOR DOME LIGHT, CEILING MOUNTEDC
CORRIDOR ZONE DOME LIGHT, WALL MOUNTEDZ
CORRIDOR ZONE DOME LIGHT, CEILING MOUNTEDZ
STAFF TERMINAL, WALL MOUNTEDST
BED CONNECTOR, WALL MOUNTEDB
PILLOW SPEAKERPS
GUEST SPEAKER, WALL MOUNTEDGS
NURSE CALL MASTER STATION, DESK MOUNTEDNM
X
WHEN THIS SYMBOL IS INDICATED ON THE NURSE CALL DRAWINGS IT IDENTIFIES THE AUDIO
CONNECTION FOR THE WALL MOUNTED TV TO THE NURSE CALL SYSTEM. SEE SHEET WITH DETAILS
FOR MORE INFORMATION
X= TYPE
TV
CODE BLUE ANNUNCIATOR PANEL, WALL MOUNTED
CBAP
NURSE CALL EQUIPMENT CABINET, WALL MOUNTED
NCEC
NURSE CALL SYSTEM CONDUIT AND WIRING
ELECTRIC MORTISE LOCK OR ELECTRIC TRIMEM
ELECTRONIC SECURITY SYSTEM
VIDEO SURVEILLANCE SYSTEMS
CARD READER, WALL MOUNTEDCR
CARD READER WITH INTEGRATED KEYPAD, WALL MOUNTEDCK
BIOMETRIC ACCESS CONTROL DEVICE, WALL MOUNTEDBR
DELAYED EGRESS MAG LOCKDM
ELECTRIC LATCH RETRACTION LOCKEL
ELECTROMAGNETIC LOCKML
ELECTRIC DOOR STRIKEES
ELECTRIC DOOR OPERATOR (ACTUATOR ARM)DO
DOOR POSITION SWITCHDPS
A
DOOR RELEASE BUTTON, WALL MOUNTED
X= A: ADA ACCESSIBLE - (PALM ACTUATOR), W: HAND WAVE, NO TYPE: REGULAR PUSH BUTTON
DOOR RELEASE BUTTON, DESK MOUNTED
REQUEST TO EXIT DEVICE (IR SENSOR), MOUNT CENTERED ABOVE DOOR FRAMEREX
DURESS PANIC BUTTON, MOUNTED UNDER DESKD
MOTION DETECTOR, WALL MOUNTED, MOUNT 6" BELOW CEILING OR 8'-0" AFF MAXMD
MOTION DETECTOR, 360 DEGREE SENSOR, CEILING MOUNTEDMD
LINE BETWEEN SECURITY DEVICES, INDICATES ASSOCIATED EQUIPMENT
I CONTROLLED DOOR INTERLOCK GROUP. PROGRAMMED SO ONLY ONE DOOR CAN BE OPEN AT A
TIME.
X
FIBER BDA
X= FIBER BDA NUMBER
BDA
Z
DAS SPLITTER
X= SPLITTER NUMBER
ROOF ANTENNA, WALL MOUNTED
X
WHEN THIS SYMBOL IS INDICATED ON THE NURSE CALL DRAWINGS IT IDENTIFIES THE AUDIO
CONNECTION FOR THE CEILING MOUNTED TV TO THE NURSE CALL SYSTEM. SEE SHEET WITH
DETAILS FOR MORE INFORMATION
X= TYPE
TV
AUDIO VISUAL EQUIPMENT
FLIP TOP DEVICE MOUNTED ON TABLEFT
MX
MICROPHONE, DESK MOUNTED
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT
X
TS
TOUCH SCREEN FOR AUDIO/VIDEO CONTROL, DESK MOUNTED
X= DENOTES TYPE OF OUTLET, SEE RISER FOR MORE INFO, IF NOT SHOWN, ONLY ONE TYPE
TT
XX
+YY
TT= DISPLAY TYPE WITH MOUNT
YY= HEIGHT TO CENTER OF SCREEN
XX= SCREEN SIZE
AUDIO VISUAL DISPLAY
Y-Z
NO ZONE INDICATES LOCAL ZONE FOR A/V SYSTEM IN ROOM
Z= DENOTES SPEAKER # IN ZONE
Y= SPEAKER ZONE
X= SPEAKER TYPE (S1=PUBLIC ADDRESS , S2=A/V SYSTEM SPEAKER)
CEILING MOUNTED SPEAKER
SX
W= DENOTES SPEAKER WATTAGE TAPW
Y-Z
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF DEVICE
Z= DENOTES SPEAKER # IN ZONE
Y= SPEAKER ZONE
X= SPEAKER TYPE
WALL MOUNTED SPEAKER
SX
W= DENOTES SPEAKER WATTAGE TAPW
+H
NO ZONE INDICATES LOCAL ZONE FOR A/V SYSTEM IN ROOM
PX
PODIUM FOR AV EQUIPMENT, REFER TO DETAIL SHEETS
X= DENOTES TYPE OF OUTLET, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT
CAMERA FOR AV SYSTEM, CEILING MOUNTED
X= DENOTES TYPE OF OUTLET, SEE RISER FOR MORE INFO, IF NOT SHOWN, ONLY ONE TYPE
AV X
+H
CAMERA FOR AV SYSTEM, WALL MOUNTED
X= DENOTES TYPE OF OUTLET, SEE RISER FOR MORE INFO, IF NOT SHOWN, ONLY ONE TYPE
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET
AV X
X MOTORIZED PROJECTION SCREEN
X= DIAGONAL DIMENSION IN INCHES
X PULLDOWN PROJECTION SCREEN
X= DIAGONAL DIMENSION IN INCHES
OVERHEAD PROJECTOR WITH MOUNT
Y= LENS THROW RATIO
X= TYPE
Y
X
BROADBAND TELEVISION SYSTEM
RX ANTENNA
TX ANTENNA
TX/RX ANTENNA
2 WAY SPLITTER
3 WAY SPLITTER
4 WAY SPLITTER
8 WAY SPLITTER
SATELLITE DISHSD
I
T= TAP LEGS, QTY AS INDICATED IN RISER
O= OUTPUT LEG
I= INPUT LEG
DISTRIBUTION TAP
O
T
I
T= TAP LEGS, QTY AS INDICATED IN RISER
O= OUTPUT LEG
I= INPUT LEG
DIRECTIONAL COUPLER
O
T
CATV TAP DEFINITION TAG
Y= TAP VALUE IN dB
X= NUMBER OF TAP LEGSXW-Y
I
O= OUTPUT LEG
I= INPUT LEG
X= EQUALIZING VALUE IN dB
CATV EQUALIZER
O
EQ
-X
TERMINATOR
SURGE SUPRESSOR AT BUILDING ENTRY POINT
X
T= TEST PORT
O= OUTPUT LEG
I= INPUT LEG
CATV AMPLIFIER
O T
I
X= AMPLIFIER TYPE - SP: SERVICE PROVIDER, H: HEADEND AMPLIFIER, D: DISTRBUTION AMPLIFIER
KEYPAD, WALL MOUNTEDKP
WIRELESS MORTISE LOCK, DOOR MOUNTEDWM
INTRUSION ALARM KEYPADIK
DELAYED EGRESS LATCH LOCKDE
ELECTRIC GATE OPERATORGO
X
MX
MICROPHONE, CEILING MOUNTED
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT
NEW EQUIPMENT
EXISTING WORK AND/OR EQUIPMENT REFERENCE, SHOWN ON MULTIPLE DRAWINGS
DEVICE TO BE REMOVED (DEMO PLANS) UNDERFLOOR CONDUIT (NEW PLANS)
MATCH LINE REFERENCING CONTINUATION ON OTHER DRAWINGS
CABLE ROUTING BOUNDARY
WIRE AND/OR CONDUIT RUN CONTINUED ON REFERENCED DETAIL
DETAIL AND/OR SECTION REFERENCE
FUTURE WORK
X
IM
INTERCOM MASTER STATION, DESK MOUNTED
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT, REFER TO RISER FOR TYPE
INFANT ABDUCTION SYSTEM, CEILING MOUNTED ABOVE DOORIA
X Y
Z Z= SPLITTER NUMBER THE ANTENNA IS ASSOCIATED WITH
Y= ANTENNA NUMBER
X= ANTENNA TYPE
DAS ANTENNA, CEILING MOUNTED
A
X Y Z +H
Z= SPLITTER NUMBER THE ANTENNA IS ASSOCIATED WITH
Y= ANTENNA NUMBER
X= ANTENNA TYPE
DAS ANTENNA, WALL MOUNTED
A
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF DEVICE
TT
XX
+YY
TT= DISPLAY TYPE WITH MOUNT
YY= HEIGHT TO CENTER OF SCREEN
XX= SCREEN SIZE
INTERACTIVE WHITEBOARD
MONITORED - DOOR MONITORED
BIOMETRIC - BIOMETRIC READER
CR - CARD READER
FREE - NO ACCESS CONTROL
ACCESS CONTROL DOOR DIRECTION, A1/A2 - REPRESENTS ACCESS CONTROL PATH
A1
CR/KP - CARD READER AND KEYPAD
A2
X
AS
ASSISTANCE STATION (BLUE LIGHT), TOWER STATION
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT, REFER TO SPECIFICATION FOR TYPE
SENS MICROPHONE FOR AMBIENT NOISE, CEILING MOUNTEDSM
FIBER OPTICS ROUTING TAG FOR BACKBONE CABLING
N= DENOTES CONNECTION TYPE (P=PRIMARY, S=SECONDARY)
XX= DENOTES FIBER STAND QUANTITY
Z= DENOTES RUN NUMBER
REFER TO FIBER OPTICS RISER FOR MORE INFORMATION.
N-XX-Z
X
PB
TELECOMMUNICATIONS PULLBOX. SEE DETAILS AND SPECS FOR MORE INFORMATION
X= BOX TYPE. IF NOT SHOWN, ONLY ONE TYPE IN PROJECT
TECHNOLOGY POLE. SEE SHEETS WITH DETAILS FOR ADDITIONAL INFORMATIONTP
BALANCED MAGNETIC SWITCHBMS
ELECTRONIC DETENTION LOCKDL
ELECTRIC CYLINDRICAL LOCKEC
WIRELESS CYLINDRICAL LOCK, DOOR MOUNTEDWC
WIRED IP LOCK, DOOR MOUNTEDIP
GATE PEDESTALGP
GLASS BREAK SENSOR, CEILING MOUNTEDGB
X +H
AV WALL BOX, REFER TO DETAIL SHEETS
X= DENOTES TYPE OF OUTLET, SEE DETAIL FOR MORE INFO, IF NOT SHOWN, ONLY ONE TYPE
AV
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 1'-6" AFF
LN
FLOOR BOX FOR TECHNOLOGY SYSTEMS AND POWER OUTLETS. REFER TO POKE-THRU/
FLOORBOX SCHEDULE FOR MORE INFORMATION
F= FLOOR CONDITION: (C= CONCRETE TYPE, G= GRADE, R= RAISED FLOOR, W= WOOD)
Y= DENOTES # OF GANGS (1,2,3...)
Z= DENOTES PLATE TYPE (A,B,C....), A= NO AUDIO/VISUAL
LN= AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
U: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
FYZ
LN
POKE-THRU FOR TECHNOLOGY SYSTEMS AND POWER OUTLETS. REFER TO POKE-THRU &
FLOOR BOX SCHEDULE FOR MORE INFORMATION
Y= DENOTES POKE-THRU SIZE (4=4", 6=6" 8=8".....)
Z= DENOTES PLATE TYPE (A,B,C....), A= NO AUDIO/VISUAL
LN= AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
U: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
YZ
X
FF
FLOOR BOX USED TO FEED CABLES TO MODULAR FURNITURE, REFER TO DETAIL SHEET
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT
X
FP
POKE-THRU USED TO FEED CABLES TO MODULAR FURNITURE, REFER TO DETAIL SHEET
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT
+H
VOLUME CONTROL, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 4'-0" AFF
VC
+H
SENS MICROPHONE FOR AMBIENT NOISE, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 8'-0" AFF
SM
+H
MICROPHONE, WALL MOUNTED
X= DENOTES TYPE OF OUTLET, IF NOT SHOWN, ONLY ONE TYPE
MX
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET
X +H
TOUCH SCREEN FOR AUDIO/VIDEO CONTROL, WALL MOUNTED, INCLUDES BACK BOX
X= DENOTES TYPE OF OUTLET, SEE RISER FOR MORE INFO, IF NOT SHOWN, ONLY ONE TYPE
TS
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 4'-0" AFF
+H
AV INPUT WALL PLATE
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET
AVI
X +H
ROOM SCHEDULING PANEL, WALL MOUNTED, INCLUDES BACK BOX
X= DENOTES TYPE OF OUTLET, SEE RISER FOR MORE INFO, IF NOT SHOWN, ONLY ONE TYPE
RS
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 4'-0" AFF
LV
WALL SWITCH FOR MOTORIZED SCREEN
+H
WIRELESS ANTENNA FOR WIRELESS MICRPHONE, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 8'-0" AFF
WA
+H
PIM MODULE FOR WIRELESS LOCKS, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 7'-0" AFF
WG
+H
ALARM, BLUE LIGHT, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 7'-0" AFF
BL
+H
LOCAL ALARM - HORN/STROBE, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 7'-0" AFF
LA
+H
SIREN ALARM FOR INTRUSION DETECTION, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 7'-0" AFF
SA
X +H
ASSISTANCE STATION, WALL MOUNTED
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT, REFER TO SPECIFICATION FOR TYPE
AS
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 4'-0" AFF
X +H
INTERCOM SUBSTATION (DOOR STATION), WALL MOUNTED
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT, REFER TO RISER FOR TYPE
IS
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 4'-0" AFF
X +H
INTERCOM MASTER STATION, WAll MOUNTED
X= TYPE, IF NOT SHOWN, ONLY ONE TYPE IN PROJECT, REFER TO RISER FOR TYPE
IM
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 4'-0" AFF
+H
CALL STATION (THROUGH PHONE LINE) FOR BUILDING ENTRY, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 4'-0" AFF
CS
+H
GLASS BREAK SENSOR, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 7'-0" AFF
GB
+H
DURESS PANIC BUTTON, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 4'-0" AFF D
+H
INFANT ABDUCTION SYSTEM, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 8'-0" AFF
IA
X U +H
TV WALL BOX WITH TV OUTLET, COORDINATE ROUGH-IN WITH TV MOUNT INSTALLER
X= DENOTES TYPE OF OUTLET, SEE DETAILS FOR MORE INFORMATION
TV
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 7'-0" AFF
U=USER(IF APPLICABLE). THIS ONLY APPLIES TO DATA AND FIBER NOT COAX
X U +H
TELEVISION OUTLET, COORDINATE ROUGH-IN WITH TV MOUNT INSTALLER, CEILING MOUNTED
X= DENOTES TYPE OF OUTLET, SEE DETAIL FOR MORE INFORMATION
TV
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 7'-0" AFF
U=USER(IF APPLICABLE). THIS ONLY APPLIES TO DATA AND FIBER NOT COAX
SY
U +H
Y: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
U: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
MECH OUTLET FOR MECHANICAL/ ELECTRICAL/ FIRE ALARM/ ELEVATOR/ STAR CONNECTION
+H= IF NOT SHOWN, COORDINATE EXACT LOCATION WITH DEVICE
XY
U +H
Y: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
U: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
WAP OUTLET FOR WIRELESS ACCESS POINT, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 8'-0" AFF
XY
U XY: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
U: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
OUTLET FOR WIRELESS ACCESS POINT, MOUNTED ON FINISHED CEILINGWAP
W,WP
XNYZ
U +H
TELECOMMUNICATION OUTLET
X= MOUNTING: (E= EXISTING, F= FLUSH, S= SURFACE, M= MODULAR FURNITURE ADAPTER,
P= POLE, L= FLOOR, R= RACEWAY)
N= NUMBER OF DATA CABLES IN THE FACEPLATE
Y= NOT USED
Z= NUMBER OF FIBER OPTIC STRANDS IN THE FACEPLATE
U= USER(IF APPLICABLE)
+H= INSTALLATION HEIGHT IN INCHES AT CENTER OF OUTLET, COORDINATE WITH
ELECTRICAL. IF NOT SHOWN INSTALL AT TYPICAL RECEPTACLE HEIGHT.
W= WALL TELEPHONE FACEPLATE WITH SUPPORT STUDS, INSTALLED AT 48" AFF AT CENTER
OF OUTLET AND 12" FROM EDGE OF WALL.
WP=WEATHERPROOF
EXAMPLE: F2 = TWO DATA JACKS IN A SINGLE FACEPLATE, FLUSH MOUNTED
XY
U XY: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
U: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
CEILING MOUNTED INFORMATION OUTLET, MOUNTED ON FINISHED CEILING
XY
U
+H XY= AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
U: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
G= DENOTES # OF GANGS
AV BACKBOX, INSTALLED BEHIND DISPLAY/ CREDENZA RACK, COORDINATE BACKBOX PRIOR TO
AG
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF DEVICE
ROUGH-IN. REFER TO DETAIL & SCHEDULE FOR MORE INFORMATION
XY
U
+H XY= AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
U: AS DESCRIBED FOR TELECOMMUNICATIONS OUTLET
G= DENOTES # OF GANGS
RECESS IN-WALL STORAGE BOX, INSTALLED BEHIND DISPLAY, COORDINATE BACKBOX PRIOR TO
RG
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF DEVICE
ROUGH-IN. REFER TO DETAIL & SCHEDULE FOR MORE INFORMATION
MASTER WIRED CLOCK SYSTEM
DOUBLE FACE WALL MOUNTED CLOCK, 8" BELOW CEILING OR 9'-0" AFF, WHICHEVER IS LOWERC1
10" DIAMETER SEMI-FLUSH CLOCK, 1'-0" BELOW CEILING OR 9'-0" AFF, WHICHEVER IS LOWERC
12" DIAMETER SEMI-FLUSH CLOCK, 1'-0" BELOW CEILING OR 9'-0" AFF, WHICHEVER IS LOWERC1
DIGITAL CLOCK, 1'-6" BELOW CEILINGD
DIGITAL ELAPSED TIME CLOCK, 6" BELOW CEILINGDL
ANALOG ELAPSED TIME CLOCK, 1'-6" BELOW CEILINGEL
ELAPSED TIMER CONTROL UNIT, 3'-8" AFFET
PATIENT CLOCK, 8'-0" AFFP
MASTER TIME CENTER, TOP OF TRIM 6'-2" AFFMC
MASTER WIRELESS CLOCK SYSTEM
GPS ANTENNA
GPS RECEIVERGPS
WIRELESS TRANSMITTER/TRANSCEIVER, SHELF MOUNTEDWT
W 12" DIAMETER SEMI-FLUSH BATTERY OPERATED CLOCK, 1'-0" BELOW CEILING OR 9'-0" AFF, WHICHEVER IS LOWER. CLOCK INDICATED WITH 120V CIRCUIT SHALL NOT BE BATTERY OPERATED
W2 DOUBLE FACE WALL MOUNTED WIRELESS CLOCK, 8" BELOW CEILING OR 9'-0" AFF, WHICHEVER IS
LOWER
W1 18" DIAMETER SEMI-FLUSH BATTERY OPERATED CLOCK, 1'-6" BELOW CEILING OR 14'-0" AFF, WHICHEVER IS LOWER. CLOCK INDICATED WITH 120V CIRCUIT SHALL NOT BE BATTERY OPERATED
CCTV
XX
+YY
FLAT PANEL DISPLAY WITH MOUNT
YY= HEIGHT TO CENTER OF SCREEN
XX= SCREEN SIZE
X
PC
SECURITY SYSTEM WORKSTATION, DESK MOUNTED
X= TYPE
X,C
PAN/TILT/ZOOM CCTV CAMERA, WALL MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
PAN/TILT/ZOOM CCTV CAMERA, CEILING MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
FIXED CCTV CAMERA, WALL MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
FIXED CCTV CAMERA, CEILING MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
360° CCTV CAMERA, WALL MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
360° CCTV CAMERA, CEILING MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
180° MULTI-IMAGER CCTV CAMERA, WALL MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
180° MULTI-IMAGER CCTV CAMERA, CEILING MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
180° CCTV CAMERA, WALL MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
180° CCTV CAMERA, CEILING MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
360° MULTI-IMAGER CCTV CAMERA, WALL MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
X,C
360° MULTI-IMAGER CCTV CAMERA, CEILING MOUNTED
X= CAMERA TYPE (1,2,3), SEE DETAIL SHEETS FOR MORE INFORMATION, C = CAMERA NUMBER
WALL MOUNTED FURNITURE FEED USED TO FEED CABLES TO MODULAR FURNITURE OR CABLESFF
XO
OCCUPANCY SENSOR, CEILING MOUNTED
X= TYPE, C= CRESNET, E= ETHERNET
+H
SOUND BAR WITH CAMERA, WALL MOUNTED
+H= MOUNTING HEIGHT IN INCHES AT CENTER OF OUTLET, IF NOT SHOWN, INSTALL AT 8'-0" AFF
SB
FC
DAS FIRE RATED ACCESS PANEL SYSTEM. REFER TO DAS ACCESS PANEL CHASE ELEVATION
ON TECHONLOGY ELEVATION SHEET FOR MORE INFORMATION
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
A
B
C
D
E
F
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:1
A
M
T-TJ-00
TECHNOLOGY SYMBOLS, LEGEND,
NOTES AND INDEX
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
TECH Sheet List
Sheet Number Sheet Name
T-TJ-00 TECHNOLOGY SYMBOLS, LEGEND, NOTES AND INDEX
T-TD-01 OVERALL BASEMENT FLOOR DEMO - TECHNOLOGY
T-TJ-01 OVERALL BASEMENT FLOOR NEW WORK - TECHNOLOGY
T-TJ-02.01A BASEMENT FLOOR PLAN AREA A & B NEW WORK - TECHNOLOGY
T-TJ-02.01B BASEMENT FLOOR PLAN AREA C NEW WORK - TECHNOLOGY
T-TJ-02.01C BASEMENT FLOOR PLAN AREA D & E NEW WORK - TECHNOLOGY
T-TJ-02.01D BASEMENT FLOOR PLAN AREA F NEW WORK - TECHNOLOGY
T-TJ-04 ENLARGED PLANS - TECHNOLOGY
T-TJ-07 TECHNOLOGY - RISER
T-TJ-08 TECHNOLOGY - DETAILS
T-TJ-09 TECHNOLOGY - DETAILS
T-TJ-10 TECHNOLOGY DETAILS
Revisions: Date:
UP
ELECTMECHSTAIR
ELECT ELEVATOR
ELEVATOR
ELEVATOR
SUPPORT
ELECT
STAIR
COMM
OFFICE OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
HR
CORR.
SERVER
HAC TELE
HR MULTI
PURPOSE
CORRIDOR
ENTRY
OFFICE
HR
CORR.
MECH
TOILET
OFFICE
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE OFFICE
OFFICE OFFICE
OFFICE
STOR
OFFICE OFFICE
OFFICE
ELEVATOR
LOBBY
CORRIDOR
TOILET
TOILET
TOILET
TOILET
PROSTHETIC
WHEELCHAIR
CLINIC
PROS
STORAGE
MRSA
OFFICE
INFECTION
CONTROL
NURSE IRM
PH/DATA
STORAGE
CORRIDOR
ISO
ENGINEERING
LOCKSMITH
VISN
LEAD
EEO
MGR
DRUG
CONTROL
PHARMACIST
CMOP
PROGRAM
MGR
TELE
CARE
TECHS
TOILET
STOR.
PHARM.
TELE
CARE
TECHS
ADPAC
MECH
MULTI
PURPOSE
INTERN
KITCHEN
TELE
CARE
TECHS
TELE
CARE
TECHS
TOILET
DAY CARE
ADMINISTRATOR
STORAGE
FOOD
PREP
TWO
YEAR
OLD
DAY
CARE
INFANT
TELE
STORSIGNAL
TOILET TOILET
CHILD
CARE 3, 4, 5
YEAR OLD
IT EQUIPMENT AND STRUCTURED
CABLING SYSTEM TO BE REMOVED
FROM IRM PH/DATA G25 AFTER NEW
IT/DATA G03A & TELECOM G03B IS
COMPLETE AND ACTIVE
EXISTING EQUIPMENT IN COMM ROOM G-
X02 TO REMAIN. PROTECT ALL CABLING
ROUTED TO THIS ROOM DURING DEMO
EXISTING INACTIVE TELE ROOM TO BE DEMO
INTERN
KITCHEN
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
A
B
C
D
E
F
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:0
A
M
T-TD-01
OVERALL BASEMENT FLOOR
DEMO - TECHNOLOGY
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
1/8" = 1'-0"
1 BASEMENT OVERALL DEMO PLAN - TECHNOLOGY
0 4' 8' 12'
1/8" = 1'-0"
2 ENTRANCE CORR DEMO - TECHNOLOGY
0 4' 8' 12'
DEMOLITION GENERAL NOTES:
1. CONTRACTOR TO REMOVE EXISTING CEILING MOUNTED AV EQUIPMENT AND TURN OVER TO VA.
2. REMOVE AND TURN OVER TO VA ALL EXISTING WIRELESS ACCESS POINTS AND PUBLIC ADDRESS SPEAKERS.
3. REMOVE ALL EXISTING DATA CABLING.
4. REMOVE AND TURN OVER TO VA ALL NURSE CALL HEAD END EQUIPMENT.
5. NEW TR MUST BE COMPLETED AND ACTIVATED BEFORE EXISTING IRM/DATA ROOM CAN BE DEMOLISHED.
6. ALL EXISTING FIBER TERMINATED IN EXISTING TR MUST BE EXTENDED TO NEW TR, TERMINATED & ACTIVATED BEFORE
EXISTING IRM/DATA ROOM CAN BE DEMOLISHED.
7. SEE ARCHITECTURAL PHASING PLAN FOR ADDITIONAL INFORMATION.
CORRIDOR TO
BUILDING 5
ADO POST
PRIMARY J-HOOK PATHWAY
55 SEATSAREA AAREA B
AREA A
AREA C
AREA CAREA B
AREA DAREA C
AREA C
AREA E
AREA D
AREA F
AREA FAREA E
BREAKROOM
G18
FITTING
G15
RECEPTION, OPTHA
G13
TOILET
G16
PULM/SLEEP STUDY
G23C
TOILET/SHOWER
G23E
PULM FUNCT, SLEEP STUDY
G23F
SOILED
G23B
CLEAN LINEN
G23A
TOILET
G23L
TELEHEALTH/ MONITORING
G23H
EXAM
G23K
EXAM
G23J
EXAM
G23I
EQUIP STOR
G24
RECEP/CHECK IN
G25
COPY/PRINT
G25A
EXAM/CPAP
G26
EXAM/CPAP
G28
TOILET
G30
EXAM/CPAP
G31
WORK
G-006G WORK
G-006F
WORK
G-006H
WORK
G-006J
WORK
G-006E
WORK
G-006D
WORK
G-006C
WORK
G-006B
SUPPLY
G-006A
COPY/FAX
G-006K
SUITE
G29
SLEEP LAB WAITING
G-011
STORAGE
G17A CONFERENCE
G17
NURSE MANAGER
G21
OFFICE
G22
HAC
G01B
TELECOM
G03B
IT/DATA
G03A
ASST CHIEF
G05
STERILE SUPPLY
G04
RME
G02A
CLEAN UTILITY
G02
EXAM
G07F PHOTOCOAG LASER
G07D
SPEC TESTING
G07C
VISUAL FIELDS
G07B
ULTRASOUND
G07A
CLINIC MANAGER
G07E
YAG LASER
G07G
TOMOGRAPHY/ CAMERA
G07H
MEDS
G07I
TOILET
G07J
SOILED
G08A
RECEIVING
G08
EXAM
G09E
EXAM
G09D
EXAM
G09B
EXAM
G09A
EXAM
G09G
EXAM
G09H
EXAM
G09I
EXAM
G09J
EXAM
G09K
FAMILY TOILET
G08B
SUB WAITING
G09
WORK
G-074C
WORK
G-074D
WORK
G-074E
WORK
G-074F
WORK
G-074GWORK
G-074B
COPY/FAX
G-074A
FILES
G-074H
CORRIDOR
G09L
ELEVATOR SUPPORT
G01A
ELEVATOR
G-X05
ELEVATOR
G-X04
WORK
G-026C
WORK
G-026D
WORK
G-026E
WORK
G-026F
WORK
G-026G
WORK
G-026H
WORK
G-026A
WORK
G-026B
COPY/PRINT
G13A
SUPPLY STO
G-026J
TOILET/SHOWER
G23D
ELECT
G03
ELECT
G12
COMM
G33
MECH
G11
MECH
G06
ELECT
G19
STAIR
G10
STAIR
G20
CORRIDOR
G07
CORRIDOR
G32
EXAM
G23M
EXAM
G09C
WAITING
G14
WORK STATIONS
G23G
CORRIDOR
G23
WORKSTATIONS
G09F
T-TJ-04
T-TJ-04
TELECOM G03B & IT/DATA G03A MUST
BE COMPLETED BEFORE DEMO BEGINS
EXISTING ACCESS
CONTROL TO REMAIN
EXIT ONLY
EXIT ONLY
EXIT ONLY
EXISTING ACCESS
CONTROL TO REMAIN
EXISTING ACCESS
CONTROL TO REMAIN
EXISTING EQUIPMENT IN COMM ROOM G33 TO
REMAIN. PROTECT ALL CABLING ROUTED TO
THIS ROOM DURING DEMO
PRIMARY J-HOOK PATHWAY
PRIMARY J-HOOK PATHWAY
PRIMARY J-HOOK PATHWAY
EXIT ONLY
EXISTING ACCESS
CONTROL TO REMAIN
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
A
B
C
D
E
F
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:3
A
M
T-TJ-01
OVERALL BASEMENT FLOOR NEW
WORK - TECHNOLOGY
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
1/8" = 1'-0"
2 ENTRANCE CORR NEW WORK - TECHNOLOGY
0 4' 8' 12' 0 4' 8' 12'
1/8" = 1'-0"
3 BASMENT OVERALL NEW WORK - TECHNOLOGY
TV
S1
S1
S1
S1
S1
CR
D P
S
REX
E S
D P
S
REX
CR
D P
S
E S
REX
TV
S1S1
S1
S1
S1
CR
D P
S
REX
E S
CR
D P
S
E S
REX
C R
ES
R E
X
DPS
C R
DPS
ES
R E
X
COPIER
MED LOCK BOX.
L
N
P
R
S
T
U
2 4 E4 E5 5 6
E-JJ
EXAM
G09E
EXAM
G09D
EXAM
G09B
EXAM
G09A
EXAM
G09G
EXAM
G09H
EXAM
G09I
EXAM
G09J
EXAM
G09K
FAMILY TOILET
G08B
SUB WAITING
G09
WORK
G-074C
WORK
G-074D
WORK
G-074E
WORK
G-074F
WORK
G-074GWORK
G-074B COPY/FAX
G-074A
FILES
G-074H
CORRIDOR
G09L
STAIR
G10
EXAM
G09C
WORKSTATIONS
G09F
WAP
S 2
F 2 F 2 F 2
F 2
F 2
F 1
F 2F 2
F 2
F 1
F 1
F 2
F 2
F 1
WAP
S 2
F 2
F 1
F 2
F 2
F 1
F 2
F 1
WAP
S 2
F 1
F 2
F 1
F 2
F 1
F 1
+66"+66"
F 2
EXIT ONLY
L 2
L 2
L 2
L 2
L 2
L 2
L 2
L 2
L 2
L 2
A
B
C
D
G
I
J
K
L
1 2
E4 E5 6
E-JJ
H
ASST CHIEF
G05
EXAM
G07F
PHOTOCOAG LASER
G07D
SPEC TESTING
G07C
VISUAL FIELDS
G07B
ULTRASOUND
G07A
CLINIC MANAGER
G07E
YAG LASER
G07G
TOMOGRAPHY/ CAMERA
G07H
MEDS
G07I
TOILET
G07J
SOILED
G08A
RECEIVING
G08
EXAM
G09A
FAMILY TOILET
G08B
SUB WAITING
G09
MECH
G06
STAIR
G10
CORRIDOR
G07
F 1
F 1 +66"+66"
WAP
S 2
360° CAMERA
WAP
S 2
F 2
F 2
F 2
F 1
F 1
W F 1
F 2F 2
F 2 F 2
F 2
F 2
F 2 F 4
F 2
F 2F 2
F 2
WAP
S 2
WAP
S 2
F 2
F 1
EXISTING ACCESS
CONTROL TO REMAIN
L 2
L 2
F 1 1
L 2
L 2
L 2
F 2
F 2
F 2
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
A
B
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:4
A
M
T-TJ-02.01A
BASEMENT FLOOR PLAN AREA A &
B NEW WORK - TECHNOLOGY
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
1/4" = 1'-0"1
BASEMENT FLOOR AREA A NEW WORK - TECHNOLOGY
1/4" = 1'-0"2
BASEMENT FLOOR AREA B NEW WORK - TECHNOLOGY
TECHNOLOGY KEYED NOTES
DATA OUTLET FOR OWNER PROVIDED REESE MONITORING SYSTEM TO BE LOCATED ABOVE DOOR AND CABLED BACK TO NEAREST DATA ROOM. COORDINATE LOCATION OF TERMINATION IN DATA ROOM WITH
OWNER IT.
DATA FOR VISUAL ACUITY MONITOR. COORDINATE EXACT LOCATION & ELEVATION WITH
ARCHITECTURAL DRAWINGS & VENDOR SHOP DRAWINGS PRIOR TO ROUGH IN
DATA OUTLET IN FLOOR BOX. SEE ELECTRICAL DRAWINGS & SPECIFICATIONS FOR ADDITIONAL
INFORMATION. COORDINATE EXACT FLOOR BOX LOCATION WITH ARCHITECTURAL DRAWINGS.
T V
A V
I
T V
S1S1S1S1S1
S1
S1
S1
S1
S1
S2 S2
D P
S
D P
S
E S
E S
CR CR
REXREX
T V
REX
D P
S
T V
CR
E S
D P
S
REX
D
D
D
MX MX
T V
CR
D P
S
E S
REX
G
I
J
K
L
M
O
Q
11 12
16 18
19 20
F
E
H
BREAKROOM
G18
FITTING
G15
RECEPTION, OPTHA
G13
TOILET
G16
STORAGE
G17A
CONFERENCE
G17
NURSE MANAGER
G21
HAC
G01B
TELECOM
G03B
IT/DATA
G03A
ASST CHIEF
G05
STERILE SUPPLY
G04
RME
G02A
CLEAN UTILITY
G02
ELEVATOR SUPPORT
G01A
ELEVATOR
G-X05
ELEVATOR
G-X04
COPY/PRINT
G13A
ELECT
G03
ELECT
G12
MECH
G11
WAITING
G14
WAP
S 2
WAP
S 2
WAP
S 2
AV
L 2 F 1
F 2
+66"+66"
W F 1
360° CAMERA
F 1
F 2
F 4
F 4
F 4
360° CAMERA
WAP
S 2
F 2
W F 1
WAP
S 2
+66"+66"
(1) 1" CONDUIT FROM FLOOR BOX TO
TV BACKBOX FOR AV INPUTS
AV INPUT WALL PLATE
(1) 1-1/2" CONDUIT FROM TV BACKBOX TO
AV INPUT WALL PLATE FOR AV
CONNECTIONS
SPEAKER CONNECTIONS TO AV INPUT
WALL PLATE AND WALL MOUNTED
DISPLAY FOR IN ROOM AUDIO
T-TJ-04
EXIT ONLY
TELECOM G03B & IT/DATA G03A MUST BE
COMPLETED BEFORE DEMO BEGINS
TELECOM G03B & IT/DATA G03A MUST BE
COMPLETED BEFORE DEMO BEGINS
F 1
+66"+66"
F 1
+66"+66"
(1) 1" CONDUIT FROM FLOOR BOX TO
AV INPUT PLATE AV INPUTS
CEILING MOUNTED MIC'S
FOR ROOM AV SYSTEM
F 1
+66"+66"
F 1
F 1
F 1 1
F 1
F 1
F 1
F 1
DATA FOR WALL MOUNTED AED.
COORDINATE EXACT LOCATION
AND TERMINATION REQUIREMENTS
WITH OWNER & VENDOR SHOP
DRAWINGS PRIOR TO ROUGH IN.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
C
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:0
A
M
T-TJ-02.01B
BASEMENT FLOOR PLAN AREA C
NEW WORK - TECHNOLOGY
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
1/4" = 1'-0"
BASEMENT FLOOR AREA C NEW WORK - TECHNOLOGY
TECHNOLOGY KEYED NOTES
DATA OUTLET FOR OWNER PROVIDED REESE MONITORING SYSTEM TO BE LOCATED ABOVE DOOR AND CABLED BACK TO NEAREST DATA ROOM. COORDINATE LOCATION OF TERMINATION IN DATA ROOM WITH
OWNER IT.
DATA FOR VISUAL ACUITY MONITOR. COORDINATE EXACT LOCATION & ELEVATION WITH
ARCHITECTURAL DRAWINGS & VENDOR SHOP DRAWINGS PRIOR TO ROUGH IN
S1
S1
S1
D P
S
CR
E S
REX
D P
S
REX
CR
D P
S
E S
REX
UP
S1S1
S1
S1
S1
D P
S
CR
E S
REX
CR
D P
S
REX
E S
TV
REX
D P
S
DD
C R
ES
DPS
R E
X
E28 E29
26 27
E-LL
BREAKROOM
G18
PULM/SLEEP STUDY
G23C
TOILET/SHOWER
G23E
PULM FUNCT, SLEEP STUDY
G23F
SOILED
G23B
CLEAN LINEN
G23A
TOILET
G23L
TELEHEALTH/ MONITORING
G23H
EXAM
G23K
EXAM
G23J
EXAM
G23I
EQUIP STOR
G24
WORK
G-026C
WORK
G-026D
WORK
G-026E
WORK
G-026F
WORK
G-026G
WORK
G-026H
WORK
G-026A
WORK
G-026B
SUPPLY STO
G-026J
TOILET/SHOWER
G23D
STAIR
G20
EXAM
G23M
WORK STATIONS
G23G
CORRIDOR
G23
WAP
S 2
F 2 F 2 F 2 F 2
F 2
F 4
F 4
F 2F 2 F 2
F 2
F 2
F 1
WAP
S 2
WAP
S 2
F 2
F 2
F 2
F 2
EXIT ONLY
3 3 3 3
F 1 1
I
J
25 E28 E29 28 29 30
BREAKROOM
G18
EQUIP STOR
G24
RECEP/CHECK IN
G25
COPY/PRINT
G25A
EXAM/CPAP
G26
EXAM/CPAP
G28
TOILET
G30
EXAM/CPAP
G31
WORK
G-006G
WORK
G-006F
WORK
G-006H
WORK
G-006J
WORK
G-006E WORK
G-006D
WORK
G-006C
WORK
G-006B
SUPPLY
G-006A
COPY/FAX
G-006K
SUITE
G29
SLEEP LAB WAITING
G-011
NURSE MANAGER
G21
OFFICE
G22
COMM
G33
ELECT
G19
STAIR
G20
CORRIDOR
G32
WAP
S 2
F 2F 2
F 2
F 2
C F 2
F 2
F 2
F 2F 2
F 2
F 2
WAP
S 2
F 2
F 2
F 1
F 2
+66"+66"
F 4 F 4
WAP
S 2
F 2
360° CAMERA
WAP
S 2
F 2 F 2
EXIT ONLY
EXISTING EQUIPMENT IN COMM ROOM G33
TO REMAIN. PROTECT ALL CABLING
ROUTED TO THIS ROOM DURING DEMO
F 2
EXISTING ACCESS
CONTROL TO REMAIN
3 3 3 3
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
D
E
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:1
A
M
T-TJ-02.01C
BASEMENT FLOOR PLAN AREA D &
E NEW WORK - TECHNOLOGY
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
1/4" = 1'-0"
BASEMENT FLOOR AREA D NEW WORK - TECHNOLOGY
1/4" = 1'-0"
BASEMENT FLOOR AREA E NEW WORK - TECHNOLOGY
TECHNOLOGY KEYED NOTES
DATA OUTLET FOR OWNER PROVIDED REESE MONITORING SYSTEM TO BE LOCATED ABOVE DOOR AND CABLED BACK TO NEAREST DATA ROOM. COORDINATE LOCATION OF TERMINATION IN DATA ROOM WITH
OWNER IT.
DATA FOR VISUAL ACUITY MONITOR. COORDINATE EXACT LOCATION & ELEVATION WITH
ARCHITECTURAL DRAWINGS & VENDOR SHOP DRAWINGS PRIOR TO ROUGH IN
COORDINATE EXACT LOCATION OF DATA OUTLET WITH ARCHITECTURAL PLANS AND FURNITURE PRIOR
TO ROUGH IN.
D P
S
E S
ES
DPSDPS
CR
REX
REX
CR
S1 S1 S1 S1
I
F 4
WAP
S 2
WAP
S 2
180° CAMERA180° CAMERA
180° CAMERA
WAP
S 2
WAP
S 2
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
F
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:3
A
M
T-TJ-02.01D
BASEMENT FLOOR PLAN AREA F
NEW WORK - TECHNOLOGY
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
1/4" = 1'-0"
BASEMENT FLOOR AREA F NEW WORK - TECHNOLOGY
DATA OUTLET FOR OWNER PROVIDED REESE MONITORING SYSTEM TO BE LOCATED ABOVE DOOR AND CABLED BACK TO NEAREST DATA ROOM. COORDINATE LOCATION OF TERMINATION IN DATA ROOM WITH
OWNER IT.
DATA FOR VISUAL ACUITY MONITOR. COORDINATE EXACT LOCATION & ELEVATION WITH
ARCHITECTURAL DRAWINGS & VENDOR SHOP DRAWINGS PRIOR TO ROUGH IN
COORDINATE EXACT LOCATION OF DATA OUTLET WITH ARCHITECTURAL PLANS AND FURNITURE PRIOR
TO ROUGH IN.
MD MD
IT/DATA
G03A
TELECOM
G03B
SE
CU
RI
TY
IN
TE
RC
O
M
RA
D
IO
D
AS
PU
BL
IC
A
D
DR
ES
S
TE
LE
VI
SI
O N
TE
LC
O T
ER
M
. F
IB
ER
C O
PP
ER
T
ER
M
IN
AT
IO
N S
FIXED CAMERA, PAN / TILT /
ZOOM, PASSIVE INFRARED
CAMERA - DUAL TECHNOLOGY
PRIMARY BONDING
GROUND BUSBAR
PRIMARY BONDING
GROUND BUSBAR
CEILING MOUNTED
MOTION SENSOR
(LOCATION AS
REQUIRED FOR FULL
ROOM COVERAGE
TWO POST RACKTWO POST RACK
RISER CONDUITS
AS REQUIRED
RISER CONDUITS
AS REQUIRED
3 55
F 1 F 1
AC-2AC-1
IT/DATA
G03A
TELECOM
G03B
F 1
TELEVISION
RADIO OR DAS
AC-1
PUBLIC ADDRESS TELEVISION
SECURITY
SECURITY
GROUND BUS BAR
F 1
AC-2
EXTENDED DEMARC
GROUND
BUS BAR
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:4
A
M
T-TJ-04
ENLARGED PLANS - TECHNOLOGY CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
1/2" = 1'-0"1
ENLARGED IT/DATA G03A & TELECOM G03B
1/2" = 1'-0"2
ENLARGED IT/DATA G-042 & TELECOM G-044 LADDER RACK
TECHNOLOGY KEY NOTES
45RU, 30"D x 7'H x 23.75"W NETWORK EQUIPMENT RACK. MIGHTY MO 20 CABLE MANAGEMENT RACK WITH WHITE
FINISH OR APPROVED EQUAL.
6" WIDE VERTICAL CABLE MANAGEMENT. WHITE MM20 VERTICAL CABLE MANAGEMENT "CAGE" OR APPROVED
EQUAL
HORIZONTAL DISTRIBUTION TO WORK AREA OUTLETS . PROVIDE 4" FIRE STOP SLEEVES AS REQUIRED FOR
DENSITY + 10% GROWTH
WIRE MESH CABLE TRAY MINIMUM OF 4" X 12" WITH SECOND LEVEL OF FIBER CHANNEL PATHWAY (4" X 4")
MAIN CROSS CONNECT (CAMPUS/BUILDING DISTRIBUTOR) - BACKBONE CABLING (MCR-TELECOMMUNICATIONS
ROOMS) PROVIDE 4" HILTI SPEED SLEEVES AS REQUIRED FOR DENSITY + 10% GROWTH
PROVIDE 4' BY 8' AC GRADE 3/4" TRADE SIZE PLYWOOD BACKBOARD ON ALL WALLS, PAINTED HIGH-GLOSS
WHITE WITH TWO COATS OF FIRE RESISTANT PAINT.
IT/DATA ROOM ELECTRICAL DESIGN BASIS
CIRCUIT VOLTS AMPS TYPE TYP LOAD DESCRIPTION
1 208V 20A EMER 50% RACK 1 - L21-20R TWIST LOCK
2 208V 20A EMER 50% RACK 2 - L21-20R TWIST LOCK
3 120V 20A NORMAL 25% TELCO
4 120V 20A NORMAL 25% CONVENIENCE OUTLETS - MIN 2 PER WALL
TELECOM ROOM ELECTRICAL DESIGN BASIS
CIRCUIT VOLTS. AMPS. TYPE. TYP LOAD. DESCRIPTION.
1 208V 20A EMER 50% RACK 1 - L21-20R TWIST LOCK
2 208V 20A EMER 50% RACK 2 - L21-20R TWIST LOCK
3 120V 20A EMER 50% SECURITY
4 120V 20A EMER 50% INTERCOM
5 120V 20A EMER 50% PUBLIC ADDRESS
6 120V 20A EMER 50% DDC
7 120V 20A EMER 50% TELEVISION
8 120V 20A EMER 50% RADIO/DAS
9 120V 20A NORMAL 25% CONVENIENCE OUTLETS - MIN 2 PER WALL
1/2" = 1'-0"3
TELECOM - N
1/2" = 1'-0"4
TELECOM - S
1/2" = 1'-0"
TELECOM - E
1/2" = 1'-0"6
TELECOM - W
1/2" = 1'-0"
IT/DATA - N
1/2" = 1'-0"8
IT/DATA - S
1/2" = 1'-0"
IT/DATA - E
1/2" = 1'-0"10
IT/DATA - W
FIRST FLOOR
SECOND FLOOR
TELECOM G03B IT/DATA G03A
BASEMENT
24 STRAND SM TO EXISTING MCR IN BUILDING 05 VIA EXISTING CRAWLSPACE CABLE TRAY AND J-HOOKS AS REQUIRED (BLDG CONNECTIVITY)
12 STRAND SM (HC)
12 STRAND MM (HC)
100 PAIR COPPER TO EXISTING PBX ROOM IN BUILDING 117 VIA EXISTING CRAWLSPACE CABLE TRAY AND J-HOOKS AS REQUIRED (BLDG CONNECTIVITY)
100 PAIR COPPER TO EXISTING PBX ROOM IN BUILDING 117 VIA EXISTING CRAWLSPACE CABLE TRAY AND J-HOOKS AS REQUIRED (BLDG CONNECTIVITY)
TECHNOLOGY GENERAL NOTES
1. COORDINATE FIBER & COPPER TERMINATION LOCATION & ROUTE WITH OWNER IT PRIOR TO INSTALL
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:5
A
M
T-TJ-07
TECHNOLOGY - RISER CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
1 FIBER & COPPER RISER DIAGRAM
F2 / F4
ROOM #
PORT #
TR # - PP #
TELEPHONE WALL PLATE
CABLE TO TR.
W F1
MAX
5'
TO COMM/DATA ROOM
NOTE:
WIRELESS ACCESS POINT AND
ANTENNA NOT IN CONTRACT.
WAP
S2
J-HOOK
ACCESSIBLE CEILING
COIL 15' SERVICE LOOP IN CEILING.
DETAIL NOTE:
COIL CABLE IN CEILING
3/4" CONDUIT
2 GANG BACK BOX
FIN. FL.
LOCATED IN TV WALL BOX AS SHOWN
IN DETAIL #5 ON SHEET T-TJ-08
RG6 COAX
CAT 6A F-TYPE ADAPTER
SINGLE GANG FACE PLATE FOR (2) MODULES
TV NOTE: ALL DATA AT TV LOCATIONS TO TERMINATE IN TV WALL BOX
2) RANDOMLY INSTALL J-HOOKS AT 3', 4' AND 5'
APART.
TREE SYSTEM IS FOR MAIN CORRIDOR PATHWAYS.
DOUBLE AND SINGLE TREES MAYBE USED IN
ROOMS. CABLE J-HOOK SYSTEM CAN BE SECURED
TO METAL STUDS, WHERE PERMISSIBLE.
NOTES:
CADDY CABLE J-HOOKS
CONCRETE ANCHOR ROOF DECK
BAR JOIST CLAMP
1)
CEILING
M
IN
M
A X
STRUCTURED CABLING
SECURITY,
CCTV, MISC.
NURSE CALL, PUBLIC
ADDRESS, CATV
3/4" CONDUIT
PROVIDE CAT6 PATCH
CORD FROM CEILING
OUTLET TO CAMERA
JUNCTION BOX
WITH DATA BISCUIT
CONDUIT STRAP
SECURED TO
STRUCTURE
CONCRETE
DECK ABOVE
"C" BRACKET AND TILE RAIL
SELF-LOCKING TAB SCREWS
LAY IN CEILING TILECEILING TEE'S
WIRING COMPARTMENT
CEILING TILE WIRE
SECURE SECONDARY
SUPPORT CABLE FROM
BUILDING STRUCTURE
SECONDARY SUPPORT TAB
L2
COVER
1" EMPTY CONDUIT WITH
PULLSTRING, RUN TO
NEAREST WALL AND STUB 6"
ABOVE ACCESSIBLE CEILING
POWER CONDUIT TO NEXT
FLOORBOX OR TO
PANELBOARD
POWER RECEPTACLE SEE
ELECTRICAL DRAWINGS
AV CHAMBERS REQUIRED FOR FLOOR
BOXES WITH "AV" SUBSCRIPT.
TELE. DATA CHAMBER
1" EMPTY CONDUIT WITH
PULLSTRING, RUN TO NEAREST
WALL AND STUB 6" ABOVE
ACCESSIBLE CEILING UNLESS
NOTED OTHERWISE ON
DRAWINGS
1" EMPTY CONDUIT WITH
PULLSTRING, RUN TO NEAREST
WALL AND STUB 6" ABOVE
ACCESSIBLE CEILING UNLESS
NOTED OTHERWISE ON
DRAWINGS
COORDINATE WITH ELECTRICAL & ARCHITECTURAL DRAWINGS
AV
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldae.com
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
A u to d e s k D o c s /2
V
A M
C S le e p
D is o rd e r
C lin ic /9
-T
V H
S A
C Y
V A
M C
S le e p
L a b
E
T
R
.r v t
/1
/2
:5
:0
A
M
T-TJ-08
TECHNOLOGY - DETAILS CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
TH07/10/2024
626-310
JK
100% CONSTRUCTION
DOCUMENTS
No Scale
WALL MOUNTED OUTLET - FOUR PORT FACEPLATE 1
No Scale
WALL PHONE OUTLET - W/FI 2
No Scale
WIRELESS ACCESS POINT (COILED IN CEILING) 3
No Scale
TV OUTLET 4No Scale
CABLE HANGER (MULTI J-HOOK) 8 No Scale
GROUND BAR 6
No Scale
INTERIOR RECESSED MOUNTED FIXED CAMERA 7 No Scale
POWER/DATA/AV FLOOR BOX 5
PROVIDE
DOUBLE-GANG BOX
WITH SINGLE GANG
MUD RING
FOR READER. SEE
FLOOR PLAN
FOR SPECIFIC TYPE
AND PLACEMENT.
44" A.F.F.
6"
4" x 4" SQUARE J-BOX.
MAGNETIC DOOR
CONTACT
SWITCH EMBEDDED IN
DOOR & DOOR FRAME
ELECTRIC STRIKE
AND
ACCOMMODATING
HARDWARE
FINISHED FLOOR
FINISHED CEILING
DOOR HARDWARE SHOWN FOR GRAPHICAL ILLISTRATION ONLY, REFERENCE DIVISION 8 HARDWARE
SCHEDULE AS NEEDED FOR ACTUAL HARDWARE SET.
3.
ALL CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED.2.
1.NOTES: CABLE TYPE AND SIZE MUST COMPLY WITH ALL ESTABLISHED REQUIREMENTS AND APPLICABLE CODES.
CABLE FOR COMMUNICATION
AND LOW VOLTAGE POWER
1" CONDUIT TO ACCESSIBLE CEILING
SPACE
ELECTRIFIED HINGE
(PROVIDED BY DOOR
HARDWARE
INSTALLER)
2" x 4" J-BOX FLUSH MOUNTED
FOR EGRESS MOTION SENSOR.
PROVIDE DOUBLE-GANG BOX
WITH SINGLE GANG MUD RING
FOR READER. SEE FLOOR PLAN
FOR SPECIFIC TYPE AND PLACEMENT.
PROVIDE DOUBLE-GANG BOX
WITH SINGLE GANG MUD RING
FOR READER. SEE FLOOR PLAN
FOR SPECIFIC TYPE AND
PLACEMENT.
44" A.F.F.
6"
44" A.F.F.
6"
ELECTRIC STRIKE AND
ACCOMMODATING
HARDWARE
FINISHED CEILING FINISHED CEILING
MAGNETIC DOOR CONTACT
SWITCH EMBEDDED IN
DOOR & DOOR FRAME
FINISHED FLOOR
DOOR HARDWARE SHOWN FOR GRAPHICAL ILLISTRATION ONLY, REFERENCE DIVISION 8 HARDWARE
SCHEDULE AS NEEDED FOR ACTUAL HARDWARE SET.
3.
ALL CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED.2.
1.NOTES: CABLE TYPE AND SIZE MUST COMPLY WITH ALL ESTABLISHED REQUIREMENTS AND APPLICABLE CODES.
4" x 4" SQUARE J-BOX.
CABLE FOR COMMUNICATION
AND LOW VOLTAGE POWER
1" CONDUIT TO ACCESSIBLE CEILING
SPACE
UNSECURE SIDE SECURE SIDE
POWER
SUPPLY
5'
MAX
WALL
1" CONCEALED CONDUIT EMT
FACEPLATE
DEEP 4 SQUARE BOX WITH
SINGLE GANG STEEL PLASTER
RING.
ACCESSIBLE CEILING
FLOOR SLAB
CABLE TRAY
J-HOOKS BY DIV. 17
COORDINATE EXACT
HEIGHT WITH
ARCHITECTURAL PLANS
AND SECTIONS PRIOR
TO ROUGH-IN
ACCESSIBLE CEILING
FINISHED FLOOR
COORDINATE WITH TV / MONITOR MOUNTING BRACKET.
CENTER BEHIND WALL MOUNTED TV / MONITOR.
AV / TV WALL BOX. SEE DETAILS
(1) 1-1/2" CONDUIT IN WALL
FOR LOW VOLTAGE CABLES
CONDUIT STUBBED ABOVE CEILING
WITH CONDUIT BUSHING
TO ELECTRICAL PANEL
(1) 3/4" CONDUIT FOR POWER
(1) 1-1/2" CONDUIT TO FLOOR BOX IF APPLICABLE. SEE TECHNOLOGY
DRAWINGS FOR LOCATION AND ADDITIONAL INFORMATION
WALL MOUNTED TV / MONITOR
AV
FSR PWB-100
BOX (OR EQUAL)
SHOWN WITH ACCESSORY
LOW-VOLTAGE CONDUIT
ENTRY BOX
120VAC POWER PROVIDED BY
ELECTRICAL CONTRACTOR
COVER TO BE
FLUSH WITH WALL
CENTER COVER TO BE
FLUSH WITH WALL
PROVIDE CATV CABLE AND FSR
CONNECTOR PLATES FOR
CONNECTION TO WALL MOUNTED
DISPLAY: PLATE #'S…