Attachment 17 - DWG - 02 - C.pdf
PDF 30 MB Posted
- Attached to
- Y1DA--626-310 Construct Sleep Disorder Clinic and Specialty Clinics Minor Construction - Murfreesboro
- Solicitation number
- 36C77625B0035
About this file
This document is a geotechnical engineering report containing detailed soil boring logs for the proposed Sleep Disorder Clinic and Specialty Clinic project at the Alvin C. York VAMC in Murfreesboro, Tennessee. The report includes four soil borings (B-1, B-2, C-1, and C-2) conducted on November 2, 2023, by Tri-State Drillering LLC using a CME-45C drill rig and hollow stem auger method. The soil samples revealed predominantly fat clay (CH) with variations in color from reddish brown to yellowish brown, with trace amounts of chert, mineral nodules, and organics. Boring depths ranged from 6.1 to 13.7 feet, with auger refusal occurring at different depths, and no groundwater was encountered during the investigation. Laboratory tests on the soil samples included Atterberg limits analysis, which classified the soils as fat clay with plasticity indices ranging from 36 to 44.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
588.5
582.9
6" TOPSOIL
FILL (CL), trace chert, dark reddish brown
FAT CLAY (CH), reddish brown with yellowish brown mottling, stiff
Auger Refusal at 6.1 Feet
Boring Log No. B-1
W at er L ev el
O bs er va tio ns
D ep th
Ft
Facilities | Environmental | Geotechnical | Materials
G ra ph ic
L og
M od el L ay er
22.1
11.4
0.5
4.0
6.1
3-5-5 N=10
3-2-7 N=9
50/1"
Abandonment Method Boring backfilled with auger cuttings upon completion.
Advancement Method Hollow Stem Auger
Hammer Type Automatic
Driller Tri-State Drillering LLC
Logged by
HA
Boring Started 11-02-2023
Boring Completed 11-02-2023
1922 Old Murfreesboro Pike Ste 905
Drill Rig
CME-45C
Proposed Improvements at Alvin C. York VAMC
Nashville, TN
3400 Lebanon Rd | Murfreesboro, TN Terracon Project No. 18235258
See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any).
See Supporting Information for explanation of symbols and abbreviations.
Notes Elevation Reference: Ground surface elevations were determined from Google Earth and are approximate
Water Level Observations Groundwater not encountered
Sa m pl e
Ty pe
W at er C on te nt
Elevation.: 589 (Ft.)
Atterberg Limits
LL-PL-PI
See Exploration PlanLocation:
Latitude: 35.9146° Longitude: -86.3781°
Depth (Ft.)
Fi el d Te st R es ul ts
2.5" TOPSOIL
FILL (CL), trace organics, reddish brown
FAT CLAY (CH), trace chert, trace mineral nodules, reddish brown, stiff
FAT CLAY (CH), trace mineral and staining, yellowish brown to reddish brown, stiff to very stiff
Auger Refusal at 11.4 Feet
586.79
575.6
Boring Log No. B-2
W at er L ev el
O bs er va tio ns
D ep th
Ft
G ra ph ic
L og
M od el L ay er
Facilities | Environmental | Geotechnical | Materials
70-26-44
0.2
3.0
6.0
11.4
3-4-3 N=7
4-4-4 N=8
6-7-6 N=13
7-8-8 N=16
23.4
29.5
36.5
34.0
Abandonment Method Boring backfilled with auger cuttings upon completion.
Advancement Method Hollow Stem Auger
Hammer Type Automatic
Driller Tri-State Drillering LLC
Logged by
HA
Boring Started 11-02-2023
Boring Completed 11-02-2023
1922 Old Murfreesboro Pike Ste 905
Drill Rig
CME-45C
Proposed Improvements at Alvin C. York VAMC
Nashville, TN
3400 Lebanon Rd | Murfreesboro, TN Terracon Project No. 18235258
See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any).
See Supporting Information for explanation of symbols and abbreviations.
Notes Elevation Reference: Ground surface elevations were determined from Google Earth and are approximate
Water Level Observations Groundwater not encountered
Sa m pl e
Ty pe
W at er C on te nt
LL-PL-PI
See Exploration PlanLocation:
Latitude: 35.9147° Longitude: -86.3781°
Depth (Ft.)
Fi el d Te st R es ul ts
Elevation.: 587 (Ft.)
Atterberg Limits
583.59
570.3
5" TOPSOIL
FILL (CL), trace chert, trace roots and organics, reddish brown
FAT CLAY (CH), trace mineral nodules and staining, trace chert, yellowish brown, stiff reddish brown reddish brown and light gray mottling
Auger Refusal at 13.7 Feet
Boring Log No. C-1
W at er L ev el
O bs er va tio ns
D ep th
Ft
Facilities | Environmental | Geotechnical | Materials
G ra ph ic
L og
M od el L ay er
18.9
26.4
22.5
23.2
63-27-36
0.4
3.0
13.7
5-6-7 N=13
3-8-6 N=14
3-5-5 N=10
4-6-6 N=12
Abandonment Method Boring backfilled with auger cuttings upon completion.
Advancement Method Hollow Stem Auger
Hammer Type Automatic
Driller Tri-State Drillering LLC
Logged by
HA
Boring Started 11-02-2023
Boring Completed 11-02-2023
1922 Old Murfreesboro Pike Ste 905
Drill Rig
CME-45C
Proposed Improvements at Alvin C. York VAMC
Nashville, TN
3400 Lebanon Rd | Murfreesboro, TN Terracon Project No. 18235258
See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any).
See Supporting Information for explanation of symbols and abbreviations.
Notes Elevation Reference: Ground surface elevations were determined from Google Earth and are approximate
Water Level Observations Groundwater not encountered
Sa m pl e
Ty pe
W at er C on te nt
Elevation.: 584 (Ft.)
Atterberg Limits
LL-PL-PI
See Exploration PlanLocation:
Latitude: 35.9154° Longitude: -86.3780°
Depth (Ft.)
Fi el d Te st R es ul ts
584.75
572.3
3" TOPSOIL
FILL (CL), trace mineral nodules, trace chert, trace organics, reddish brown to yellowish brown
FAT CLAY (CH), trace chert, trace mineral nodules, reddish brown, stiff
FAT CLAY (CH), trace mineral nodules and staining, yellowish brown to reddish brown, very stiff
Auger Refusal at 12.7 Feet
Boring Log No. C-2
W at er L ev el
O bs er va tio ns
D ep th
Ft
Facilities | Environmental | Geotechnical | Materials
G ra ph ic
L og
M od el L ay er
20.3
33.3
26.3
31.4
0.3
3.0
6.0
12.7
5-6-6 N=12
4-5-5 N=10
6-8-9 N=17
6-9-8 N=17
Abandonment Method Boring backfilled with auger cuttings upon completion.
Advancement Method Hollow Stem Auger
Hammer Type Automatic
Driller Tri-State Drillering LLC
Logged by
HA
Boring Started 11-02-2023
Boring Completed 11-02-2023
1922 Old Murfreesboro Pike Ste 905
Drill Rig
CME-45C
Proposed Improvements at Alvin C. York VAMC
Nashville, TN
3400 Lebanon Rd | Murfreesboro, TN Terracon Project No. 18235258
See Exploration and Testing Procedures for a description of field and laboratory procedures used and additional data (If any).
See Supporting Information for explanation of symbols and abbreviations.
Notes Elevation Reference: Ground surface elevations were determined from Google Earth and are approximate
Water Level Observations Groundwater not encountered
Sa m pl e
Ty pe
W at er C on te nt
Elevation.: 585 (Ft.)
Atterberg Limits
LL-PL-PI
See Exploration PlanLocation:
Latitude: 35.9150° Longitude: -86.3779°
Depth (Ft.)
Fi el d Te st R es ul ts
0 20406080100
CH
or
O H
CL
or
O L
ML or OL
MH or OH
"U " L ine
"A" L ine
ATTERBERG LIMITS RESULTS
ASTM D4318
PLASTIC
ITY
IN
D
EX
LIQUID LIMIT
5217 Linbar Dr, Ste 309 Nashville, TN
PROJECT NUMBER: 18235258
SITE: 3400 Lebanon Rd Murfreesboro, TN
PROJECT: Proposed Improvements at Alvin C. York VAMC - Murfreeesboro
CLIENT: Atriax PLLC Hickory, NC
LA
BO
R
AT
O R
Y
TE
ST
S
AR
E
N O
T
VA
LI
D
IF
S
EP
AR
AT
ED
F R
O M
O R
IG
IN
AL
R
EP
O
R T.
A
TT
ER
BE
R
G L
IM
IT
S
PR
O
PO
SE
D
IM
PR
O
VE
M
_U
PD
AT
ED
.G
PJ
T
ER
R
AC
O N
_D
AT
AT
EM
PL
AT
E.
G
D T
1/
/2
LL PL PI
B-2
C-1
Fines
3.5 - 5
3.5 - 5
CH
CH
CH- Fat CLAY
CH- Fat CLAY
DescriptionUSCSBoring ID Depth (Ft)
CL-ML
Scale: NTS1 GEOTECHNICAL ENGINEERING REPORT - SOIL BORINGS
626A4-21-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
214 Centerview Drive Suite 300
Brentwood, TN 37027 615.370.8500woldae.com
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
703 MAIN AVE SW
HICKORY, NC 28602
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
07/10/2024
MURFREESBORO, TN
100% CONSTRUCTION
DOCUMENTS
7/10/2023
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HJM
AutoCAD SHX Text
JTK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GEOTECHNICAL BORINGS REPORT
AutoCAD SHX Text B-101
32" WILLOW
M.H.(ELEC)
M.H.(ELEC)
T.C.=575.58
M.H.(STS)
28" WILLOW
36" WILLOW
T.C.=581.26
C.I.(SIN)
T.C.=586.06
M.H.(SAS)
CO
AREA DRAIN
SPIGGOT
AREA DRAIN
T.C.=586.14
M.H.(SAS)
T.C.=581.91
C.I.(SIN)
T.C.=584.40
M.H.(SAS)
30" WILLOW
06" CHERRY
6" HOLLY
T.C.=582.46
M.H.(STS)
T.C.=581.08
C.I.(SIN)
36" OAK
ELEC
INV.=575.23
24" RCP
INV.=575.45
24" RCP
INV.=575.37
6" IRON
6" IRON/DIR
24" RCP/DIR
INV.=575.19
6" IRON
6" IRON/DIR
INV.=577.89
6" PIPE
T.C.=581.16
M.H.(STS)
6" PIPE/DIR
INV.=574.49
12" RCP
12" RCP/DIR
INV.=577.76
10" RCP
INV.=578.05
10" RCP
INV.=582.60
10" RCP/DIR
INV.=0.00
10" RCP/DIR
INV.=578.62
6" IRON
INV.=0.00
6" IRON/DIR
INV.=573.74
8" PIPE
INV.=573.16
8" PIPE
INV.=574.47
8" PIPE
INV.=574.44
8" PIPE
T.C.=585.84
M.H.(SAS)
INV.=573.52
6" PIPE
6" PIPE/DIR
INV.=573.46
6" PIPE 6" PIPE/DIR
INV.=0.00
8" PIPE/DIR
6" DIR
INV.=576.17
6" PIPE
INV.=576.24
6" PIPE
6" PIPE/DIR
T.C.=579.70
M.H.(SAS)
INV.=571.59
8" PIPE
T.C.=585.96
M.H.(STS)
CALL BOX
24" RCP/DIR
INV.=578.21
6" PIPE
6" PIPE/DIR
INV.=578.01
6" PIPE6" PIPE/DIR
T.C.=585.26
M.H.(SAS)
INV.=575.01
8" PIPE
8" PIPE/DIR
T.C.=578.72
M.H.(STS)
ELEC
ELEC
T.C.=579.47
M.H.(STS)
30" WILLOW
24" WILLOW
30" OAK
10" MAGNOLIA
48" WILLOW
06" POPLAR
INV.=571.67
24" RCP
INV.=571.43
18" RCP
INV.=570.62
24" RCP
INV.=0.00
18" RCP/DIR
T.C.=576.59
C.I.(SIN)
T.C.=576.58
C.I.(SIN)
INV.=569.39
24" RCP
INV.=0.00
24" RCP/DIR
T.C.=584.82
C.B.(SIN)
INV.=580.69
8" RCP
T.C.=581.06
M.H.(STS)
8" RCP/DIR
SIGN
SIGN
SIGN
SIGN
DUMPSTER PAD
W/FENCE
CONCRETE
C O
N C
R
ET
E
ASPHALT
GRAVEL
RETAINING
WALL
RETAINING
WALL
T.C.=585.73
M.H.(STS)
INV.=572.79
24" RCP
INV.=572.82
24" RCP
24" RCP/DIR
PARKING LOT SIGN
(EMPLOYEE PARKING ONLY)
PARKING LOT SIGN
(EMPLOYEE PARKING ONLY)
SIGN
GRAVEL
LAWN
LAWN
LAWN
T
E
PB
TB
AND CURRENT TITLE SEARCH MAY DISCLOSE.
OWNERSHIP TITLE EVIDENCE, OR ANY OTHER FACTS THAT AN ACCURATE
EASEMENTS OF RECORD, ENCUMBRANCES, RESTRICTIVE COVENANTS,
SURVEYOR HAS MADE NO INVESTIGATION OR INDEPENDENT SEARCH FOR
STOP - CAUTION!!!
BEFORE YOU DIG CALL 811 AT LEAST
48 HOURS PRIOR TO CONSTRUCTION
GRAPHIC SCALE
1" = 20'
20'0 40'10'
Scale: 1:201 SITE TOPOGRAPHIC SURVEY - EXISTING CONDITIONS
626A4-21-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
214 Centerview Drive Suite 300
Brentwood, TN 37027 615.370.8500woldae.com
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
703 MAIN AVE SW
HICKORY, NC 28602
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
07/10/2024
MURFREESBORO, TN
A
B
C
D
E
100% CONSTRUCTION
DOCUMENTS
F
7/10/2023
BUILDING 6
SLEEP CLINIC
BUILDING 5
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TELEPHONE MANHOLE
AutoCAD SHX Text
PARK BENCH
AutoCAD SHX Text
TELEPHONE BOX
AutoCAD SHX Text
GAS VALVE
AutoCAD SHX Text
GAS METER
AutoCAD SHX Text
FIRE HYDRANT
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
AutoCAD SHX Text
MAJOR CONTOUR LINE
AutoCAD SHX Text
CURB
AutoCAD SHX Text
EDGE OF CONC.
AutoCAD SHX Text
TREE
AutoCAD SHX Text
LIGHT POLE
AutoCAD SHX Text
BENCHMARK
AutoCAD SHX Text
MANHOLE
AutoCAD SHX Text
ELECTRIC MANHOLE
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
STORM SEWER
AutoCAD SHX Text
SANITAY SEWER
AutoCAD SHX Text
GAS
AutoCAD SHX Text
WATER
AutoCAD SHX Text
EXISTING BUILDING
AutoCAD SHX Text
AutoCAD SHX Text
CONTOUR LINE
AutoCAD SHX Text
THIS IS NOT A BOUNDARY SURVEY.
AutoCAD SHX Text
DEED REFERENCE FOR THE PROPERTY SURVEYED IS D.B. 84, PGS. 1-8,
AutoCAD SHX Text
AS OF RECORD IN REGISTER'S OFFICE FOR RUTHERFORD COUNTY, TENNESSEE.
AutoCAD SHX Text
OR ENTITIES WITHOUT AN EXPRESSED RE-CERTIFICATION BY THE SURVEYOR
AutoCAD SHX Text
THE ORIGINAL PURCHASER AND DOES NOT EXTEND TO ANY UNNAMED PERSON
AutoCAD SHX Text
US GOVERNMENT VA HOSPITAL MURFREESBORO
AutoCAD SHX Text
ALL DISTANCES WERE MEASURED WITH E.D.M. EQUIPMENT AND HAVE
AutoCAD SHX Text
UTILITIES HAVE BEEN PLOTTED FROM SURFACE FEATURES FOUND AT
AutoCAD SHX Text
THE TIME OF SURVEY AND AVAILABLE MAPS AND RECORDS. THERE MAY
AutoCAD SHX Text
BE OTHER UTILITIES, THE EXISTENCE OF WHICH ARE NOT KNOWN TO
AutoCAD SHX Text
SURVEYOR'S LIABILITY FOR THIS DOCUMENT SHALL BE LIMITED TO
AutoCAD SHX Text
WHOSE SIGNATURE APPEARS ON THIS SURVEY.
AutoCAD SHX Text
THE UNDERSIGNED.
AutoCAD SHX Text
OWNER OF RECORD BEING:
AutoCAD SHX Text
BEEN ADJUSTED FOR
AutoCAD SHX Text
TEMPERATURE.
AutoCAD SHX Text 1)
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text 2)
AutoCAD SHX Text 3)
AutoCAD SHX Text 4)
AutoCAD SHX Text
BEING A PORTION OF TAX MAP 59, PARCEL 53.00
AutoCAD SHX Text
OF
AutoCAD SHX Text
VA HOSPITAL
AutoCAD SHX Text
BUILDING #107
AutoCAD SHX Text
PARTIAL TOPOGRAPHIC SURVEY
AutoCAD SHX Text
DATE: 11-01-2021:REVISED: 1-18-2022(ADDED TOPO)
AutoCAD SHX Text
MURFREESBORO-RUTHERFORD COUNTY-TENNESSEE
AutoCAD SHX Text
MURFREESBORO
AutoCAD SHX Text
WOLD/HFR PROJECT NO. 217040
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HJM
AutoCAD SHX Text
JTK
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING CONDITIONS
AutoCAD SHX Text
SITE TOPOGRAPHIC SURVEY
V-101
M.H.(ELEC)
T.C.=575.58
M.H.(STS)
28" WILLOW
36" WILLOW
T.C.=581.26
C.I.(SIN)
T.C.=586.06
M.H.(SAS)
CO
AREA DRAIN
SPIGGOT
AREA DRAIN
T.C.=586.14
M.H.(SAS)
T.C.=581.91
C.I.(SIN)
T.C.=584.40
M.H.(SAS)
30" WILLOW
06" CHERRY
6" HOLLY
T.C.=582.46
M.H.(STS)
T.C.=581.08
C.I.(SIN)
36" OAK
ELEC
INV.=575.23
24" RCP
INV.=575.45
24" RCP
INV.=575.37
6" IRON
6" IRON/DIR
24" RCP/DIR
INV.=575.19
6" IRON
6" IRON/DIR
INV.=577.89
6" PIPE
T.C.=581.16
M.H.(STS)
6" PIPE/DIR
INV.=574.49
12" RCP
12" RCP/DIR
INV.=577.76
10" RCP
INV.=578.05
10" RCP
INV.=582.60
10" RCP/DIR
INV.=0.00
10" RCP/DIR
INV.=578.62
6" IRON
INV.=0.00
6" IRON/DIR
INV.=573.74
8" PIPE
INV.=573.16
8" PIPE
INV.=574.47
8" PIPE
INV.=574.44
8" PIPE
T.C.=585.84
M.H.(SAS)
INV.=573.52
6" PIPE
6" PIPE/DIR
INV.=573.46
6" PIPE 6" PIPE/DIR
INV.=0.00
8" PIPE/DIR
6" DIR
INV.=576.17
6" PIPE
INV.=576.24
6" PIPE
6" PIPE/DIR
T.C.=579.70
M.H.(SAS)
INV.=571.59
8" PIPE
T.C.=585.96
M.H.(STS)
CALL BOX
24" RCP/DIR
INV.=578.21
6" PIPE
6" PIPE/DIR
INV.=578.01
6" PIPE6" PIPE/DIR
T.C.=585.26
M.H.(SAS)
INV.=575.01
8" PIPE
8" PIPE/DIR
T.C.=578.72
M.H.(STS)
ELEC
ELEC
T.C.=579.47
M.H.(STS)
30" WILLOW
24" WILLOW
30" OAK
10" MAGNOLIA
48" WILLOW
06" POPLAR
INV.=571.67
24" RCP
INV.=571.43
18" RCP
INV.=570.62
24" RCP
INV.=0.00
18" RCP/DIR
T.C.=576.59
C.I.(SIN)
T.C.=576.58
C.I.(SIN)
INV.=569.39
24" RCP
INV.=0.00
24" RCP/DIR
T.C.=584.82
C.B.(SIN)
INV.=580.69
8" RCP
T.C.=581.06
M.H.(STS)
8" RCP/DIR
SIGN
SIGN
SIGN
SIGN
DUMPSTER PAD
W/FENCE
CONCRETE
C O
N C
R
ET
E
ASPHALT
GRAVEL
RETAINING
WALL
RETAINING
WALL
T.C.=585.73
M.H.(STS)
INV.=572.79
24" RCP
INV.=572.82
24" RCP
24" RCP/DIR
PARKING LOT SIGN
(EMPLOYEE PARKING ONLY)
PARKING LOT SIGN
(EMPLOYEE PARKING ONLY)
SIGN
GRAVEL
LAWN
LAWN
LAWN
LO
C
LO
C
LO
C
LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOC LOC
LO
C
LOC LOC LOC
LO
C
LOC LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
X X X X X
X X
X X
X
XXXXXXX
X X
X
XXX
X X
X X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X
X
X X X X
X X
X
X
X
X X X
X
LOC
LOC LO
C
X
X
X
X
X
X
X
X
X
X
XX
PROTECT EX.
STORMWATER MANHOLE
LIMITS OF
CONSTRUCTION
LIMITS OF
CONSTRUCTION
CONSTRUCTION
FENCE
CONSTRUCTION
FENCE
LIMITS OF
CONSTRUCTION
CONSTRUCTION
FENCE
TREE
PROTECTION
TREE
PROTECTION 10
PROTECT EX. HYDRANT
AND VALVE IN PLACE
SEE ARCHITECTURE SHEETS
FOR BUILDING/FACADE DEMOLITION
PLANS
LIMITS OF
CONSTRUCTION
CONSTRUCTION
FENCE
PROTECT LAMP POST
IN PLACE
PROTECT EXISTING
DUMPSTER ENCLOSURE.
RELOCATE IF NEEDED TO
MAINTAIN OPERATION.
PROTECT EXISTING
AREA INLET IN PLACE.
LOC LOC
DEMOLITION OF EXISTING
SITE FEATURES
LIMITS OF CONSTRUCTION
REMOVE EXISTING TREES
LEGEND
TREE PROTECTION
SITE CONSTRUCTION SECURITY FENCE
X X
STOP - CAUTION!!!
BEFORE YOU DIG CALL 811 AT LEAST
48 HOURS PRIOR TO CONSTRUCTION
GRAPHIC SCALE
1" = 20'
20'0 40'10'
Scale: 1:201 CIVIL SITE DEMOLITION PLAN
626A4-21-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
214 Centerview Drive Suite 300
Brentwood, TN 37027 615.370.8500woldae.com
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
703 MAIN AVE SW
HICKORY, NC 28602
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
07/10/2024
MURFREESBORO, TN
A
B
C
D
E
100% CONSTRUCTION
DOCUMENTS
F
7/10/2023
NOTES:
1. CONTACT VA STAFF ONE WEEK PRIOR TO STARTING WORK.
2. CONTRACTOR SHALL COORDINATE ALL WORK WITH COR TO MAINTAIN CONTINUOUS
ACCESS AND UTILITY SERVICE DURING BUSINESS HOURS THROUGHOUT
CONSTRUCTION.
3. FULL EXTENT OF EXISTING UTILITIES ARE NOT SHOWN. CONTRACTOR SHALL
PERFORM LOCATES TO CONFIRM LOCATION OF EXISTING UTILITIES PRIOR TO
STARTING WORK.
4. WHERE SANITARY SEWER PIPE IS TO BE DEMOLISHED AND REPLACED, THE
CONTRACTOR SHALL COORDINATE DEMO/REPLACEMENT WITH THE COR.
5. DO NOT DAMAGE STORMWATER STRUCTURES, BOXES, OR PIPES TO REMAIN ON
SITE. SHOULD ANY BE DAMAGED, CONTACT THE COR IMMEDIATELY.
6. PROTECT ALL FACADES, VEGETATION, UTILITIES, CURB AND GUTTER, AND
HARDSCAPES NOT MARKED FOR DEMOLITION.
7. CONTRACTOR SHALL DISCUSS ALL ITEMS TO BE REMOVED WITH THE COR; SALVAGE
ITEMS AS DIRECTED.
8. ALL ITEMS TO REMAIN PROPERTY OF THE VA SHALL BE TURNED OVER TO THE VA.
9. SIGNS AND OTHER SITE ITEMS TO BE REINSTALLED SHALL BE STORED AND
PROTECTED FROM DAMAGE DURING REMOVAL/REINSTALLATION, AND SHALL BE
REINSTALLED TO MATCH EXISTING OR AS DIRECTED BY THE COR. IF ITEMS ARE
DAMAGED, CONTACT THE COR.
10. REMOVE TREES AS MARKED, GRIND UP/REMOVE STUMP, AND GRUB ROOTS TO
DEPTH OF 18".
11. WHERE STORMWATER PIPES/STRUCTURES ARE TO BE DEMOLISHED, BACKFILL AND
COMPACT TRENCHES AS REQUIRED TO REESTABLISH GRADE.
12. DEMOLITION SHALL INCLUDE UNDERGROUND ROOF DRAIN PIPES AT NEW
ENTRANCE; DEMO TO BUILDING FACADE.
13. NEATLY SAWCUT AND REMOVE PAVEMENT, CONCRETE SIDEWALK, CURB & GUTTER
SECTIONS AS SHOWN. DEMOLISH FULL SLABS AND MATCH EXISTING JOINTING
PATTERN FOR REPLACEMENT CURB AND GUTTER AND SIDEWALK.
14. ALL MATERIALS NOT RETURNED TO VA SHALL BECOME PROPERTY OF THE
CONTRACTOR. HAUL OFF ALL DEBRIS FROM SITE AND DISPOSE OF IN ACCORDANCE
WITH VA STANDARDS, APPLICABLE STATE AND FEDERAL LAWS.
15. CONTRACTOR SHALL BE RESPONSIBLE FOR USE OF FALL ARREST SYSTEMS, TRENCH
BOXES, AND ALL OTHER MEASURES AS REQUIRED BY OSHA DURING CONSTRUCTION.
16. ABANDONED PIPES ARE TO BE REMOVED.
17. CONTRACTOR TO CONFIRM FLOW DIRECTION OF EXISTING STORMWATER PIPES PRIOR
TO DEMOLITION TO PREVENT LEAVING ACTIVE LINES WITHOUT AN OUTLET. IF THIS
CONDITION IS FOUND, CONTACT COR IMMEDIATELY.
DEMOLITION KEY NOTES
1. DEMOLISH CONCRETE CURB AND GUTTER TO FURTHEST JOINT, REMOVE
WHOLE SECTIONS.
2. DEMOLISH CONCRETE SIDEWALK, UTILITY PAD, STAIRS, RAMPS, RAILINGS.
3. DEMOLISH CRAWL SPACE ACCESS.
4. REMOVE TREE, GRIND UP STUMP, AND GRUB ROOTS UNDER CANOPY.
5. REMOVE AND STORE SIGNS AND POSTS FOR REINSTALLATION.
6. DEMOLISH STORMWATER PIPE, INLET STRUCTURES.
7. REMOVE EXISTING LOT SIGN, RETURN TO VA.
8. DEMOLISH EXISTING BUILDING DIRECTIONAL SIGN.
9. DEMOLISH EXISTING STORMWATER PIPE BACK TO MANHOLE.
10. ERADICATE PAVEMENT MARKINGS AT PARKING STALLS.
11. DEMOLISH EXISTING ASPHALT ROAD AND PARKING LOTS AS MARKED.
12. UNDER PROPOSED BUILDING EXPANSION, REMOVE AND REPLACE EXISTING
STORMWATER MANHOLE. COORDINATE DEMOLITION WITH COR. SEE 06 C-102
FOR MORE INFORMATION.
13. REMOVE ALL WHEEL STOPS AND RETURN TO VA.
14. DEMOLISH EXISTING LAMP POSTS AND FOOTINGS, CUT AND CAP ELECTRICAL
LINES.
15. CUT AND CAP WATER LINE, DEMOLISH EXISTING WATER SERVICE LINE AS
MARKED.
16. DEMOLISH SPIGOT AND DRAIN AT CONCRETE.
17. DEMOLISH EXISTING SANITARY PIPE.
18. DEMOLISH EXISTING SANITARY STRUCTURE.
19. DEMOLISH AND CAP STORMWATER PIPE; CONFIRM DIRECTION OF FLOW
PRIOR TO DEMO.
BUILDING 6
SLEEP CLINIC
BUILDING 5
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HJM
AutoCAD SHX Text
JTK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CIVIL SITE DEMOLITION PLAN
CD101
T.C.=586.06
M.H.(SAS)
CO
AREA DRAINT.C.=586.14
M.H.(SAS)
T.C.=584.40
M.H.(SAS)
30" WILLOW
06" CHERRY
36" OAK
ELEC
T.C.=585.84
M.H.(SAS)
T.C.=579.70
M.H.(SAS)
T.C.=585.26
M.H.(SAS)
ELEC
ELEC
30" WILLOW
24" WILLOW
30" OAK
10" MAGNOLIA
48" WILLOW
06" POPLAR
LO
C
LO
C
LO
C
LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOC LOC
LO
C
LOC LOC LOC
LO
C
LOC LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
S T
S T
S T
ST
ST
LOC
LOC LO
C
R 48.5'
ST
ST
.3
3'
6'
8'
18'
5'
18'
8'
11'
5'6'
8'
19.25'
3'
F O
C
116.9' FOC
10.33'
6'
.2
.7
3'
.5
.8 2'
41.2'
.1
6.
5'
32.56'
.1
5'
30.66'
6'
.2
5'
47.75'
14.5' 8'
30' 5'
15'
9.
'14 .5
10'
10'
.7 5'
.1
6'
14.42'
28'
6'
3'
8'30'
12'
8' 6.54'
8'
4.5'
20' FOC
5'
4'
4' 21'
3'
2'
R14.5'
R14.5' R19.5'
R5.5
R5.5'
R29 .5'
R6.5
R14.5'
R 19.5'
R19.5'
R40.5'
R40.5'
R 19.5'
R3.5'
ST
ST
ST
SS
SS
' F
O C
.8
1'
35.44'
7.
LIMITS OF
CONSTRUCTION
NEW MAIN ENTRANCE BUILDING
FOR SLEEP CLINIC: SEE AE 1.01D,
ARCHITECTURE PLANS FOR MORE
INFORMATION.
NEW AWNING STRUCTURE
AT PATIENT DROP-OFF.
SEE STRUCTURAL SHEETS
S1.00 - S4.51 FOR MORE
INFORMATION.
TIE NEW CURB
TO EXISTING
TIE NEW CURB
TO EXISTING
TIE NEW CURB
TO EXISTING
TIE NEW ASPHALT
TO EXISTING,
SLOPE TO DRAIN
TIE NEW ASPHALT TO
EXISTING, SLOPE TO
DRAIN
LOC LOC LIMITS OF CONSTRUCTION
589.2
CONCRETE HARDSCAPES.
ASPHALT PAVEMENT
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
SPOT ELEVATION FE U.N.O.
FOUNDATION DRAIN
WATER LINE - DUCTILE IRON
SANITARY PIPE - SCH. 80 PVC
UG ELECTRICAL - 2" CONDUIT
LAMP POST
48"x48" RC STORMWATER STRUCTURE
12" STORMWATER PIPE - DOUBLE WALL HDPE
ROOF LEADER DRAIN - SCH. 80 PVC
STORM SEWER CLEANOUT
SANITARY SEWER CLEANOUT
SANITARY SEWER MANHOLE STRUCTURE
SIGN POST
W
SS
UGE
S T
SD
ST
SS
STOP - CAUTION!!!
BEFORE YOU DIG CALL 811 AT LEAST
48 HOURS PRIOR TO CONSTRUCTION
GRAPHIC SCALE
1" = 20'
20'0 40'10'
Scale: 1:201 CIVIL SITE PLAN
626A4-21-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
214 Centerview Drive Suite 300
Brentwood, TN 37027 615.370.8500woldae.com
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
703 MAIN AVE SW
HICKORY, NC 28602
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
07/10/2024
MURFREESBORO, TN
A
B
C
D
E
100% CONSTRUCTION
DOCUMENTS
F
7/10/2023
NOTES:
1. CONTRACTOR SHALL COORDINATE WORK AND PHASING WITH VA, TRADES, AND
OTHERS AS REQUIRED TO PREVENT DAMAGE/REPLACEMENT OF NEW WORK.
2. CONTRACTOR SHALL COORDINATE ALL WORK WITH COR TO MAINTAIN
CONTINUOUS ACCESS AND UTILITY SERVICE DURING BUSINESS HOURS
THROUGHOUT CONSTRUCTION.
3. UNLESS NOTED OTHERWISE, DIMENSIONS ARE FROM BACK OF CURB OR EDGE
OF SIDEWALK.
4. WORK SHALL OCCUR WITHIN THE LIMITS OF DISTURBANCE AS SHOWN.
5. EXISTING CURB AND GUTTER, SIDEWALKS, ASPHALT, AND OTHER SITE
FEATURES THAT ARE TO REMAIN SHALL BE PROTECTED. WHERE NEW TIES TO
EXISTING, SAW CUT, PROTECT, AND KEEP EXISTING CLEAN. EXISTING AND NEW
SHALL TIE TOGETHER. WHERE WIDTHS DIFFER, TAPER TO MATCH EXISTING.
6. ALL SIDEWALKS CONSTRUCTED ON SITE SHALL MEET ACCESSIBLE ROUTE
REQUIREMENTS, AND SHALL HAVE A MAXIMUM RUNNING SLOPE OF 3%, AND
MAXIMUM CROSS SLOPE OF 2%.
9. SIDEWALKS ADJACENT TO BUILDING FACADES OR WALLS SHALL BE SLOPED
AWAY FROM THE BUILDING USING A MINIMUM CROSS SLOPE OF 1%.
10. PROTECT BUILDING FACADE FROM DAMAGE DURING ALL PHASES OF WORK.
11. CONSTRUCT ADA RAMPS AND ASSOCIATED LANDINGS IN CONFORMANCE WITH
DETAILS PROVIDED AND THE STANDARDS AND SPECIFICATIONS OF THE
DEPARTMENT OF VETERANS AFFAIRS. MAX RAMP RUNNING SLOPE OF 5%. MAX
CROSS SLOPE OF 2%.
12. IN ALL CASES, AT NEAREST JOINT FOR PROPOSED WORK, CUT EXISTING
CONCRETE AND INSTALL EXPANSION JOINT, INSTALL NEW
CURB/GUTTER/SIDEWALK TO TIE TO EXISTING.
KEY NOTES
1. CONSTRUCT CONCRETE SIDEWALK: 1/C-501
2. CONSTRUCT 6" VERTICAL CURB & GUTTER: 2/C-501
3. CONSTRUCT MOUNTABLE CURB & GUTTER: 3/C-501
4. CONSTRUCT FLUSH CURB AT LOADING ZONE: 4/C-501
5. CONSTRUCT ASPHALT ROADWAY: 5/C-501
6. CONSTRUCT FLUSH SIDEWALK AT LOADING ZONE: 1/C-503
7. CONSTRUCT DIRECTIONAL ADA RAMP: 2/C-503
8. CONSTRUCT 90° DIRECTIONAL ADA RAMP: 3/C-503
9. TRANSITION FROM MOUNTABLE TO FLUSH CURB: 9/C-501
10. TRANSITION FORM MOUNTABLE TO VERTICAL CURB, TIE TO EXISTING: 10/C-501
11. CONSTRUCT MECHANICAL PAD: SEE 11/C-501
12. CONSTRUCT NEW LAMP POSTS, CONCRETE FOOTING: SEE 12/C-501.
BUILDING 6
SLEEP CLINIC
BUILDING 5
LEGEND
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HJM
AutoCAD SHX Text
JTK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CIVIL SITE PLAN
C-101
M.H.(ELEC)
T.C.=575.58
M.H.(STS)
T.C.=586.06
M.H.(SAS)
CO
AREA DRAINT.C.=586.14
M.H.(SAS)
T.C.=584.40
M.H.(SAS)
30" WILLOW
06" CHERRY
T.C.=582.46
M.H.(STS)
36" OAK
ELEC
T.C.=581.16
M.H.(STS)
T.C.=585.84
M.H.(SAS)
T.C.=579.70
M.H.(SAS)
T.C.=585.96
M.H.(STS)
T.C.=585.26
M.H.(SAS)
T.C.=578.72
M.H.(STS)
ELEC
ELEC
T.C.=579.47
M.H.(STS)
30" WILLOW
24" WILLOW
30" OAK
10" MAGNOLIA
48" WILLOW
06" POPLAR
T.C.=576.59
C.I.(SIN)
T.C.=576.58
C.I.(SIN)
T.C.=584.82
C.B.(SIN)
T.C.=581.06
M.H.(STS)
LO
C
LO
C
LO
C
LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOC LOC
LO
C
LOC LOC LOC
LO
C
LOC LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
S T
S T
S T
ST
ST
LOC
LOC LO
C
2+43
0+00
1+
2+00
0+00 0+87
SD 1
SD 2
SD 3
L1
L3 L4
L5
C
C2
C3
L6L7 C4C5
583.1
584.5
583.8 584.6
584.858 4.1
582.6
582.1
583.7
585.2
585.6
5.4
586.0
584.9
582.5
582.7
582.0 -1
.2
-1 .3
-2 .0
-1.0%
-1.
5%
-1.
0%
-1 .0
-2.0%
-1 .8
1.1%
-1 .8%
XSDMH
FFE: 5
.6
ST
ST
-1.4% -2.0%
NORTHING: 575985.3,
EASTING: 1856656.1
NORTHING: 576110.5,
EASTING: 1856576.2
NORTHING: 576031.6,
EASTING: 1856610.4
NORTHING: 576035.9,
EASTING: 1856524.2
NORTHING: 576032.6,
EASTING: 1856559.0
-2
.0
-2 .0
3.4
582.5
582.9
3.6
ST
ST
NORTHING: 575942.6,
EASTING: 1856618.3
NORTHING: 575944.6,
EASTING: 1856596.4
NORTHING: 575946.6,
EASTING: 1856574.1
NORTHING: 575864.7,
EASTING: 1856536.7
NORTHING: 575862.0,
EASTING: 1856567.2
NORTHING: 575810.6,
EASTING: 1856531.8
NORTHING: 575807.8,
EASTING: 1856562.3
NORTHING: 575842.6,
EASTING: 1856534.7
NORTHING: 575839.8,
EASTING: 1856565.2
NORTHING: 575829.8,
EASTING: 1856564.3
NORTHING: 575832.5,
EASTING: 1856533.8
ST
SS
SS
LIMITS OF
CONSTRUCTION
Alignment - Drop Off
NUMBER
L1
C1
C2
L3
L4
C3
L5
STARTING POINT
NORTHING, EASTING
576110.52, 1856576.18
576061.49, 1856563.08
575997.29, 1856555.98
575964.82, 1856583.19
575963.48, 1856598.13
575962.14, 1856613.07
575968.31, 1856634.20
BEGIN
STATION
0+00.00
0+50.75
1+15.41
1+62.44
1+77.44
1+92.44
2+14.98
END
STATION
0+50.75
0+68.20
1+62.44
1+77.44
1+92.44
2+14.98
2+42.73
LENGTH
50.75
17.45
47.04
15.00
15.00
22.54
27.75
RADIUS
100.000
30.000
30.000
LINE/CHORD DIRECTION
S14° 57' 37.29"W
S09° 57' 37.29"W
S39° 57' 19.59"E
S84° 52' 16.47"E
S84° 52' 17.17"E
N73° 43' 30.17"E
N52° 11' 57.02"E
Alignment - Driveway
NUMBER
L6
C4
C5
L7
STARTING POINT
NORTHING, EASTING
576031.63, 1856610.40
576033.61, 1856589.49
576032.68, 1856578.73
576031.75, 1856567.96
BEGIN
STATION
0+00.00
0+21.00
0+31.87
0+42.73
END
STATION
0+21.00
0+31.87
0+42.73
0+86.73
LENGTH
21.00
10.87
10.87
44.00
RADIUS
30.000
30.000
LINE/CHORD DIRECTION
N84° 34' 15.37"W
S85° 03' 07.61"W
S85° 03' 03.28"W
N84° 34' 24.02"W
LOC LIMITS OF CONSTRUCTION
589.2
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
SPOT ELEVATION FE U.N.O.
STOP - CAUTION!!!
BEFORE YOU DIG CALL 811 AT LEAST
48 HOURS PRIOR TO CONSTRUCTION
GRAPHIC SCALE
1" = 20'
20'0 40'10'
Scale: 1:201 GRADING AND ALIGNMENT PLAN
626A4-21-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
214 Centerview Drive Suite 300
Brentwood, TN 37027 615.370.8500woldae.com
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
703 MAIN AVE SW
HICKORY, NC 28602
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
07/10/2024
MURFREESBORO, TN
A
B
C
D
E
100% CONSTRUCTION
DOCUMENTS
F
7/10/2023
NOTES:
1. CONTRACTOR SHALL COORDINATE WORK AND PHASING WITH VA, TRADES, AND
OTHERS AS REQUIRED TO PREVENT DAMAGE/REPLACEMENT OF NEW WORK.
2. CONTRACTOR SHALL COORDINATE ALL WORK WITH COR TO MAINTAIN
CONTINUOUS ACCESS AND UTILITY SERVICE DURING BUSINESS HOURS
THROUGHOUT CONSTRUCTION.
3. UNLESS NOTED OTHERWISE, DIMENSIONS ARE FROM BACK OF CURB OR EDGE
OF SIDEWALK.
4. WORK SHALL OCCUR WITHIN THE LIMITS OF DISTURBANCE AS SHOWN.
5. EXISTING CURB AND GUTTER, SIDEWALKS, ASPHALT, AND OTHER SITE
FEATURES THAT ARE TO REMAIN SHALL BE PROTECTED. WHERE NEW TIES TO
EXISTING, SAW CUT, PROTECT, AND KEEP EXISTING CLEAN. EXISTING AND NEW
SHALL TIE TOGETHER. WHERE WIDTHS DIFFER, TAPER TO MATCH EXISTING.
6. ALL SIDEWALKS CONSTRUCTED ON SITE SHALL MEET ACCESSIBLE ROUTE
REQUIREMENTS, AND SHALL HAVE A MAXIMUM RUNNING SLOPE OF 3%, AND
MAXIMUM CROSS SLOPE OF 2%.
9. RAMP AND SIDEWALKS ADJACENT TO BUILDING FACADES OR WALLS SHALL BE
SLOPED AWAY FROM THE BUILDING USING A MINIMUM CROSS SLOPE OF 1%.
10. PROTECT BUILDING FACADE FROM DAMAGE DURING ALL PHASES OF WORK.
11. CONSTRUCT ADA RAMPS AND ASSOCIATED LANDINGS IN CONFORMANCE WITH
DETAILS PROVIDED AND THE STANDARDS AND SPECIFICATIONS OF THE
DEPARTMENT OF VETERANS AFFAIRS. MAX RAMP RUNNING SLOPE OF 5%. MAX
CROSS SLOPE OF 2%.
Scale: NTS2 NEW ROAD ALIGNMENTS DATA
LEGEND
BUILDING 6
SLEEP CLINIC
BUILDING 5
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HJM
AutoCAD SHX Text
JTK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRADING AND ALIGNMENT PLAN
C-102
M.H.(ELEC)
T.C.=575.58
M.H.(STS)
T.C.=586.06
M.H.(SAS)
CO
AREA DRAINT.C.=586.14
M.H.(SAS)
T.C.=584.40
M.H.(SAS)
30" WILLOW
06" CHERRY
T.C.=582.46
M.H.(STS)
36" OAK
ELEC
INV.=575.23
24" RCP
INV.=575.45
24" RCP
INV.=575.37
6" IRON
6" IRON/DIR
24" RCP/DIR
INV.=575.19
6" IRON
6" IRON/DIR
T.C.=581.16
M.H.(STS)
INV.=574.49
12" RCP
12" RCP/DIR
INV.=582.60
10" RCP/DIR
INV.=573.74
8" PIPE
INV.=573.16
8" PIPE
INV.=574.47
8" PIPE
INV.=574.44
8" PIPE
T.C.=585.84
M.H.(SAS)
INV.=573.52
6" PIPE
6" PIPE/DIR
INV.=573.46
6" PIPE 6" PIPE/DIR
INV.=0.00
8" PIPE/DIR
6" DIR
INV.=576.17
6" PIPE
INV.=576.24
6" PIPE
6" PIPE/DIR
T.C.=579.70
M.H.(SAS)
INV.=571.59
8" PIPE
T.C.=585.96
M.H.(STS)
24" RCP/DIR
INV.=578.21
6" PIPE
6" PIPE/DIR
INV.=578.01
6" PIPE6" PIPE/DIR
T.C.=585.26
M.H.(SAS)
INV.=575.01
8" PIPE
8" PIPE/DIR
T.C.=578.72
M.H.(STS)
ELEC
ELEC
T.C.=579.47
M.H.(STS)
30" WILLOW
24" WILLOW
30" OAK
10" MAGNOLIA
48" WILLOW
06" POPLAR
INV.=571.67
24" RCP
INV.=571.43
18" RCP
INV.=570.62
24" RCP
INV.=0.00
18" RCP/DIR
T.C.=576.59
C.I.(SIN)
T.C.=576.58
C.I.(SIN)
INV.=569.39
24" RCP
INV.=0.00
24" RCP/DIR
T.C.=584.82
C.B.(SIN)
INV.=580.69
8" RCP
T.C.=581.06
M.H.(STS)
8" RCP/DIR
INV.=572.79
24" RCP
INV.=572.82
24" RCP
24" RCP/DIR
LO
C
LO
C
LO
C
LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOC LOC
LO
C
LOC LOC LOC
LO
C
LOC LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
SS
SS
SS
SD
S T
S T
SD
SD
SD
SD
SD
S T
SS MH 1
SS MH 2
SSMH3
ST
ST
LOC
LOC LO
C
SD 1
SD 2
SD 3
XSDMH
ST
ST
UG
E
U G
E
W
W W
W
W
UG
E
UGE
UGE
UGE
UG
E
U G
E
UG
E
U G
E
U G
E
U G
E
UG
E
UGE
U G
E
UGE
UGE
UGE
UGE
UG
E
U G
E
UGE
U
G E
UGE
ST
ST
ST
SS
SS
SS
SS
SS
LIMITS OF
CONSTRUCTION
LIMITS OF
CONSTRUCTION
TIE NEW DRAIN PIPES TO
EXISTING STRUCTURE
TIE NEW PIPES TO
EXISTING STRUCTURE
TIE NEW PIPES TO
EXISTING STRUCTURE
6" ELBOW 45°
6" ELBOW 45°
6" ELBOW 45°
6" ELBOW 45°
8 3
LOC LIMITS OF CONSTRUCTION
589.2
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
SPOT ELEVATION FE U.N.O.
FOUNDATION DRAIN
WATER LINE - DUCTILE IRON
SANITARY PIPE - SCH. 80 PVC
UG ELECTRICAL - 2" CONDUIT
LAMP POST
48"x48" RC STORMWATER STRUCTURE
12" STORMWATER PIPE - DOUBLE WALL HDPE
ROOF LEADER DRAIN - SCH. 80 PVC
STORM SEWER CLEANOUT
SANITARY SEWER CLEANOUT
SANITARY SEWER MANHOLE STRUCTURE
SIGN POST
W
SS
UGE
S T
SD
ST
SS
STOP - CAUTION!!!
BEFORE YOU DIG CALL 811 AT LEAST
48 HOURS PRIOR TO CONSTRUCTION
GRAPHIC SCALE
1" = 20'
20'0 40'10'
Scale: 1:201 UTILITIES AND DRAINAGE PLAN
626A4-21-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
214 Centerview Drive Suite 300
Brentwood, TN 37027 615.370.8500woldae.com
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
703 MAIN AVE SW
HICKORY, NC 28602
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
07/10/2024
MURFREESBORO, TN
A
B
C
D
E
100% CONSTRUCTION
DOCUMENTS
F
7/10/2023
NOTES:
1. CONTRACTOR SHALL COORDINATE WORK AND PHASING WITH VA,
TRADES, AND OTHERS AS REQUIRED TO PREVENT
DAMAGE/REPLACEMENT OF NEW WORK.
2. CONTRACTOR SHALL COORDINATE ALL WORK WITH COR TO MAINTAIN
CONTINUOUS ACCESS AND UTILITY SERVICE DURING BUSINESS HOURS
THROUGHOUT CONSTRUCTION.
3. UNLESS NOTED OTHERWISE, DIMENSIONS ARE FROM BACK OF CURB OR
EDGE OF SIDEWALK.
4. WORK SHALL OCCUR WITHIN THE LIMITS OF DISTURBANCE AS SHOWN.
5. EXISTING CURB AND GUTTER, SIDEWALKS, ASPHALT, AND OTHER SITE
FEATURES THAT ARE TO REMAIN SHALL BE PROTECTED. WHERE NEW
TIES TO EXISTING, SAW CUT, PROTECT, AND KEEP EXISTING CLEAN.
EXISTING AND NEW SHALL TIE TOGETHER. WHERE WIDTHS DIFFER,
TAPER TO MATCH EXISTING.
6. ALL SIDEWALKS CONSTRUCTED ON SITE SHALL MEET ACCESSIBLE
ROUTE REQUIREMENTS, AND SHALL HAVE A MAXIMUM RUNNING SLOPE
OF 3%, AND MAXIMUM CROSS SLOPE OF 2%.
9. RAMP AND SIDEWALKS ADJACENT TO BUILDING FACADES OR WALLS
SHALL BE SLOPED AWAY FROM THE BUILDING USING A MINIMUM CROSS
SLOPE OF 1%.
10. PROTECT BUILDING FACADE FROM DAMAGE DURING ALL PHASES OF
WORK.
11. CONSTRUCT ADA RAMPS AND ASSOCIATED LANDINGS IN
CONFORMANCE WITH DETAILS PROVIDED AND THE STANDARDS AND
SPECIFICATIONS OF THE DEPARTMENT OF VETERANS AFFAIRS. MAX
RAMP RUNNING SLOPE OF 5%. MAX CROSS SLOPE OF 2%.
12. CONTRACTOR SHALL PROVIDE SMOOTH CONNECTION AT PIPES AND
INLET STRUCTURES. MORTAR/SEAL AROUND PIPES AND PROVIDED
CONCRETE INVERTS IN ALL STORM/SANITARY STRUCTURES, TIE INVERT
TO INVERT.
KEY NOTES
1. 48"x48" TRAFFIC RATED REINFORCED CONCRETE STORMWATER
STRUCTURE, ROLL CURB, OPEN THROAT INLET AND GRATE: 2/C-502
2. UNDER PROPOSED BUILDING EXPANSION, REMOVE AND REPLACE
EXISTING STORMWATER MANHOLE WITH NEW 48"x48"48" TRAFFIC
RATED REINFORCED CONCRETE JUNCTION STRUCTURE. CAP WITH
REINFORCED CONCRETE LID. SEAL BETWEEN EXISTING PIPES AND
NEW STRUCTURE BOX. NEW CONCRETE INVERT TIE TO EXISTING
INVERTS: SEE 1/C-505.
3. STORMWATER DOWNSPOUT CLEANOUT: 4/C-502
4. 12" DOUBLEWALL HDPE STORMWATER PIPE: 1/C-502
5. 3" ROOF LEADERS AND AWNING DRAINS TIE TO STORMWATER
CLEANOUTS. 6" SCH. 80 PVC PIPE FROM CLEANOUT TO STORMWATER
STRUCTURE. TIE TO STORMWATER STRUCTURE: 5/C-502
6. INSTALL 48" DIAMETER TRAFFIC RATE REINFORCED CONCRETE
SANITARY SEWER MANHOLE: 1/C-509
7. 8" SCH. 80 PVC SANITARY SEWER PIPE. TIE TO EXISTING/NEW
SANITARY MANHOLE STRUCTURES: 3/C-502
8. 4" SCH. 80 PVC SANITARY SEWER LATERAL: SEE 3/C-502 AND
P-PP-01.01D FOR MORE INFORMATION.
9. SANITARY SEWER CLEANOUT: 6/C-502
10. SITE LIGHTING, LAMPPOST WITH CONCRETE FOUNDATION. SEE
E-EI-09 AND E-ES-01 FOR MORE INFORMATION.
11. LIGHTING AT AWNING STRUCTURE: SEE E-EI-09 AND E-ES-01 FOR
MORE INFORMATION.
12. TIE ELECTRICAL LINES FROM NEW LAMP POSTS AND AWNING
STRUCTURE BACK TO NEW ENTRANCE STRUCTURE, RECONNECT
EXISTING LAMP POSTS TO SYSTEM IF DISCONNECTED DURING
CONSTRUCTION, INSTALL NEW ELECTRICAL JUNCTION BOXES AS
REQUIRED TO CONNECT THE SYSTEM, 2" CONDUIT, MIN. 24 " BELOW
FINISHED GRADE: SEE E-ES-01 FOR MORE INFORMATION.
13. TIE FOUNDATION DRAINS TO STORMWATER STRUCTURE.
14. PVC ELECTRICAL CONDUIT, TIE TO EQUIPMENT PAD FROM BUILDING,
SEE E-ES-01.
15. RE-ROUTE WATER LINE, TIE BACK TO EXISTING PIPES, DUCTILE IRON
PIPE, AWWA STANDARD C600. CONTRACTOR VERIFY EXISTING PIPE
SIZE AND MATERIAL, RESTRAINED BENDS, MIN. 36" BELOW FINISHED
GRADE: SEE 5/C-509 FOR THRUST BLOCK DETAIL.
16. FREESTANDING DOOR PUSH PAD W/ CONCRETE FOOTING,
COORDINATE LOCATION WITH COR: SEE E-EP-02.01D.
17. INSTALL CLEANOUT BOOTS AT ALL ROOF AND AWNING DOWNSPOUTS
AT SLEEP CLINIC ENTRANCE: 4/C-502
BUILDING 6
SLEEP CLINIC
BUILDING 5
LEGEND
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HJM
AutoCAD SHX Text
JTK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
UTILITIES AND DRAINAGE PLAN
C-103
T.C.=586.06
M.H.(SAS)
CO
AREA DRAINT.C.=586.14
M.H.(SAS)
T.C.=584.40
M.H.(SAS)
30" WILLOW
06" CHERRY
36" OAK
ELEC
T.C.=585.84
M.H.(SAS)
T.C.=579.70
M.H.(SAS)
T.C.=585.26
M.H.(SAS)
ELEC
ELEC
30" WILLOW
24" WILLOW
30" OAK
10" MAGNOLIA
48" WILLOW
06" POPLAR
LO
C
LO
C
LO
C
LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOC LOC
LO
C
LOC LOC LOC
LO
C
LOC LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
S T
S T
S T
ST
ST
LOC
LOC LO
C
ST
ST
ST
ST
ST
SS
SS
LIMITS OF
CONSTRUCTION
8 7
6'
8'
18'
5'
18'
8'
11'
5'6'
8'
1'
116.9'
LOC LIMITS OF CONSTRUCTION
589.2
CONCRETE HARDSCAPES.
ASPHALT PAVEMENT
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
SPOT ELEVATION FE U.N.O.
FOUNDATION DRAIN
WATER LINE - DUCTILE IRON
SANITARY PIPE - SCH. 80 PVC
UG ELECTRICAL - 2" CONDUIT
LAMP POST
48"x48" RC STORMWATER STRUCTURE
12" STORMWATER PIPE - DOUBLE WALL HDPE
ROOF LEADER DRAIN - SCH. 80 PVC
STORM SEWER CLEANOUT
SANITARY SEWER CLEANOUT
SANITARY SEWER MANHOLE STRUCTURE
SIGN POST
W
SS
UGE
S T
SD
ST
SS
STOP - CAUTION!!!
BEFORE YOU DIG CALL 811 AT LEAST
48 HOURS PRIOR TO CONSTRUCTION
GRAPHIC SCALE
1" = 20'
20'0 40'10'
Scale: 1:201 PAVEMENT MARKING AND SIGNAGE PLAN
626A4-21-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
214 Centerview Drive Suite 300
Brentwood, TN 37027 615.370.8500woldae.com
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
703 MAIN AVE SW
HICKORY, NC 28602
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
07/10/2024
MURFREESBORO, TN
A
B
C
D
E
100% CONSTRUCTION
DOCUMENTS
F
7/10/2023
NOTES:
1. CONTRACTOR SHALL COORDINATE WORK AND PHASING WITH VA, TRADES, AND
OTHERS AS REQUIRED TO PREVENT DAMAGE/REPLACEMENT OF NEW WORK.
2. CONTRACTOR SHALL COORDINATE ALL WORK WITH COR TO MAINTAIN
CONTINUOUS ACCESS AND UTILITY SERVICE DURING BUSINESS HOURS
THROUGHOUT CONSTRUCTION.
3. UNLESS NOTED OTHERWISE, DIMENSIONS ARE FROM BACK OF CURB OR EDGE
OF SIDEWALK.
4. WORK SHALL OCCUR WITHIN THE LIMITS OF DISTURBANCE AS SHOWN.
5. EXISTING CURB AND GUTTER, SIDEWALKS, ASPHALT, AND OTHER SITE
FEATURES THAT ARE TO REMAIN SHALL BE PROTECTED. WHERE NEW TIES TO
EXISTING, SAW CUT, PROTECT, AND KEEP EXISTING CLEAN. EXISTING AND NEW
SHALL TIE TOGETHER. WHERE WIDTHS DIFFER, TAPER TO MATCH EXISTING.
6. ALL SIDEWALKS CONSTRUCTED ON SITE SHALL MEET ACCESSIBLE ROUTE
REQUIREMENTS, AND SHALL HAVE A MAXIMUM RUNNING SLOPE OF 3%, AND
MAXIMUM CROSS SLOPE OF 2%.
9. SIDEWALKS ADJACENT TO BUILDING FACADES OR WALLS SHALL BE SLOPED
AWAY FROM THE BUILDING USING A MINIMUM CROSS SLOPE OF 1%.
10. PROTECT BUILDING FACADE FROM DAMAGE DURING ALL PHASES OF WORK.
11. CONSTRUCT ADA RAMPS AND ASSOCIATED LANDINGS IN CONFORMANCE WITH
DETAILS PROVIDED AND THE STANDARDS AND SPECIFICATIONS OF THE
DEPARTMENT OF VETERANS AFFAIRS. MAX RAMP RUNNING SLOPE OF 5%. MAX
CROSS SLOPE OF 2%.
KEY NOTES
1. INSTALL VAN ACCESSIBLE ADA PARKING SIGN (R7-8 AND R7-8P):
SEE DETAILS 1 - 2/C-504
2. INSTALL ACCESSIBLE ADA PARKING SIGN (R7-8): 3/C-504
3. INSTALL DOUBLE SIDED "PATIENT PARKING ONLY" SIGN: 4/C-504
4. INSTALL "DO NOT ENTER" (R5-1) SIGN FACING ROAD AND STOP
SIGN (R1-1) FACING DRIVEWAY: 1/C-504 AND 4/C-504
5. AT COLUMNS FOR AWNING STRUCTURE, INSTALL "NO PARKING"
SIGNS ON COLUMNS (R7-1d), COORDINATE INSTALL WITH COR:
6. INSTALL NEW "SLEEP CLINIC" SIGN, CORRDINATE WITH COR: SEE
8/C-504
7. MARK PARKING LOT AS SHOWN: 6/C-504
8. MARK ADA PARKING STALLS AS SHOWN: 6/C-504
9. MARK CROSS-WALK AS SHOWN: 7/C-504
10. MARK STOP BAR, 24" WIDE.
11. INSTALL WHEEL STOPS AT ADA PARKING STALLS AS SHOWN:
5/C-504
12. INSTALL STOP SIGN (R1-1): 4/C-504
13. REINSTALL SPEED LIMIT SIGNS: 4/C-504
LEGEND
BUILDING 6
SLEEP CLINIC
BUILDING 5
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HJM
AutoCAD SHX Text
JTK
AutoCAD SHX Text
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
PAVEMENT MARKING AND SIGNAGE
C-104
M.H.(ELEC)
T.C.=575.58
M.H.(STS)
T.C.=586.06
M.H.(SAS)
CO
AREA DRAINT.C.=586.14
M.H.(SAS)
T.C.=584.40
M.H.(SAS)
30" WILLOW
06" CHERRY
T.C.=582.46
M.H.(STS)
36" OAK
ELEC
T.C.=581.16
M.H.(STS)
T.C.=585.84
M.H.(SAS)
T.C.=579.70
M.H.(SAS)
T.C.=585.96
M.H.(STS)
T.C.=585.26
M.H.(SAS)
T.C.=578.72
M.H.(STS)
ELEC
ELEC
T.C.=579.47
M.H.(STS)
30" WILLOW
24" WILLOW
30" OAK
10" MAGNOLIA
48" WILLOW
06" POPLAR
T.C.=576.59
C.I.(SIN)
T.C.=576.58
C.I.(SIN)
T.C.=584.82
C.B.(SIN)
T.C.=581.06
M.H.(STS)
LO
C
LO
C
LO
C
LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOC LOC
LO
C
LOC LOC LOC
LO
C
LOC LOC LOC LOC LOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LOCLOCLOCLOCLOCLOCLOCLOC
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
LO
C
X X X X X
X X
X X
X
XXXXXXX
X X
X
XXX
X X
X X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X
X
X X X X
X X
X
SF
SF
SF
X
X X X X
X
SS MH 1
SS MH 2
SSMH3
LOC
LOC LO
C
X
X
X
X
X
X
X
X
X
X
XX
FFE: 5
.6
W
W W
W
W
SF
SF
SS
SS
LIMITS OF
CONSTRUCTION
LIMITS OF
CONSTRUCTION
CHAINLINK
SECURITY FENCE
CHAINLINK SECURITY
FENCE
TS
PS
TS
PSTS
PS
TS
PS
SF
IP
IP
IP
CF
CF
CF
CE
TP
TP
TP
IP
TRAFFIC CONTROL PLAN PROVIDED BY
CONTRACTOR. COORDINATE ANY ROAD
CLOSURES OR DETOURS WITH COR.
CONCRETE
CLEANOUT
TS
PS
TS
PS
SF
CHAINLINK
SECURITY FENCE
CHAINLINK SECURITY
FENCE
CF
CE
CF
SF
IP
TS
PS
CONSTRUCTION ENTRANCE: 3/C-510
CONSTRUCTION FENCE:
SILT FENCE: 1/C-511
INLET PROTECTION: 1/C-512
TEMPORARY SEEDING: 2/C-510
PERMANENT SODDING: 5/C-510
TREE PROTECTION: 4/C-510
EROSION CONTROL MEASURES
IDENTIFICATION LEGEND
TP
LOC LIMITS OF CONSTRUCTION
SF
CONSTRUCTION ENTRANCE
SILT FENCE
DRAINAGE ARROW
INLET PROTECTION MEASURE
TREE PROTECTION
SITE CONSTRUCTION SECURITY FENCE
EROSION CONTROL LEGEND
X X
STOP - CAUTION!!!
BEFORE YOU DIG CALL 811 AT LEAST
48 HOURS PRIOR TO CONSTRUCTION
GRAPHIC SCALE
1" = 20'
20'0 40'10'
Scale: 1:201 EROSION AND SEDIMENT CONTROL STABILIZAITON PLAN
626A4-21-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
214 Centerview Drive Suite 300
Brentwood, TN 37027 615.370.8500woldae.com
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2023
TLC No.:
www.tlc-engineers.com
923116
703 MAIN AVE SW
HICKORY, NC 28602
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
CONSTRUCT SLEEP DISORDER CLINIC
AND SPECIALTY CLINIC
07/10/2024
MURFREESBORO, TN
A
B
C
D
E
100% CONSTRUCTION
DOCUMENTS
F
7/10/2023
EROSION AND SEDIMENT CONTROL
MAINTENANCE NOTES:
1. TOTAL AREA DISTURBED DURING CONSTRUCTION: 34,600 SQ. FT. OR 0.79
ACRES.
2. CONTRACTOR SHALL COORDINATE ALL WORK WITH WOMENS HEALTH CLINIC
TO MAINTAIN CONTINUOUS ACCESS AND UTILITY SERVICE DURING BUSINESS
HOURS THROUGHOUT CONSTRUCTION.
3. ALL EROSION, INLET PROTECTION, AND SEDIMENT CONTROL MEASURES
SHALL BE CHECKED FOR STABILITY AND OPERATION AT LEAST ONCE A WEEK
AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN
ONE-QUARTER OF A INCH (DURING A 24-HOUR PERIOD). CONTRACTOR SHALL
TAKE IMMEDIATE CORRECTIVE ACTION FOR ANY DEVICE FAILURE
4. CONTRACTOR SHALL INSPECT ALL OUTFLOWS WHERE STORMWATER RUNOFF
LEAVES THE CONSTRUCTION SITE OR ENTERS AN EXISTING STORMWATER
SYSTEMS, BMP, OR WETLAND. CORRECTIVE ACTION MUST BE TAKEN IF
SEDIMENT IS DEPOSITED OFF SITE, OR INTO THE STORMWATER SYSTEM, BMP,
OR WETLAND.
5. SEDIMENT SHALL BE REMOVED FROM BEHIND THE SILT FENCE WHEN IT
BECOMES ABOUT 0.5 FT DEEP AT THE FENCE. THE SILT FENCE SHALL BE
REPAIRED AS NECESSARY TO MAINTAIN THE BARRIER.
6. TEMPORARY SEEDING SHALL OCCUR IF DISTURBED SOILS ARE TO REMAIN
UNTOUCHED FOR MORE THAN SEVEN (7) DAYS. TEMPORARY SEEDING SHALL
BE DISTRIBUTED TO STABILIZE THE SITE, AND SHALL BE APPROPRIATELY
MAINTAINED. THIS INCLUDES CUTTING AND FERTILIZING.
7. ALL SEEDED AREAS SHALL BE FERTILIZED, RESEED AS NECESSARY, AND
MULCHED AS SPECIFIED TO MAINTAIN VIGOROUS, DENSE VEGETATIVE COVER.
8. ALL STORMWATER INLETS AND INLET PROTECTION MEASURES ARE TO BE
KEPT CLEAR OF DEBRIS, OR SEDIMENT SHOULD ANY ACCUMULATE.
9. ROADS ARE TO BE KEPT CLEAR OF DEBRIS OR SEDIMENT.
10. CONSTRUCTION ENTRANCES ARE TO BE MAINTAINED TO ENSURE CONTINUED
FUNCTIONALITY THROUGHOUT THE PROJECT.
11. RECORDS SHALL BE KEPT OF ALL INSPECTIONS AND ANY CORRECTIVE
ACTIONS TAKEN BY THE CONTRACTOR.
12. FINAL STABILIZATION OF THE SITE SHALL CONSIST OF SODDING (TURF TYPE
TALL FESCUE) AND ALL REQUIRED SITE PREPARATION (TOPSOIL, FERTILIZER,
WATERING, ETC.) FOR THE SUCCESSFUL ESTABLISHMENT OF THE SOD.
13. ALL EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL SITE IS
FULLY STABILIZED, AND APPROVED BY THE COR.
14. CONSULT THE TENNESSEE EROSION AND SEDIMENT CONTROL HANDBOOK
FOR MORE INFORMATION ON MEASURES AND BEST PRACTICES.
15. SOIL STOCKPILES ON SITE SHALL HAVE SILT FENCE ON THE DOWN SLOPE SIDE
OF THE STOCKPILE.
BUILDING 6
SLEEP CLINIC
BUILDING 5
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HJM
AutoCAD SHX Text
JTK
AutoCAD SHX Text
AutoCAD SHX Text
STABILIZATION PLAN
AutoCAD SHX Text
EROSION AND SEDIMENT CONTROL
C-105
-0+20.00 0+00.00 0+50.00
0+00.00 0+50.00
0+00.00 1+00.00
-0+20.00 0+00.00 1+00.00 1+50.00
0+00.00 1+00.00 1+50.00
SS 1
SS 2
P1
P1
P3
P2
STRUCTURE TABLE
STRUCTURE
NAME:
SD 1
SD 2
SD 3
XSDMH
STRUCTURE DETAILS:
Rectangular Junction Structure NF
RIM = 582.57
P1 INV OUT = 577.000
Rectangular Junction Structure NF
RIM = 581.77
P1 INV IN = 576.100
P2 INV IN = 576.100
P3 INV OUT = 576.000
Rectangular Junction Structure NF
RIM = 581.44
P2 INV OUT = 576.700
Cylindrical Junction Structure NF
RIM = 580.89
P3 INV IN = 574.490
PIPES IN:
P1, 12"
INV OUT =576.10
P2, 12"
INV OUT =576.10
P3, 12"
INV OUT =574.49
PIPES OUT:
P1, 12"
INV OUT =577.00
P3, 12"
INV OUT =576.00
P2, 12"
INV OUT =576.70
NORTHING,
EASTING:
576023.4, 1856589.1
576061.2, 1856573.6
576060.5, 1856552.3
576136.1, 1856565.1
PIPE TABLE
PIPE NAME
P1
P2
P3
SIZE
in.
LENGTH
ft.
40.9
19.9
75.4
SLOPE
2.2%
3.0%
2.0%
MATERIAL
HDPE Pipe
HDPE Pipe
HDPE Pipe
SSMH3
SS MH 1
SS MH 2
SD 1
SD 2
XSDMH
SD 2SD 3
STRUCTURE TABLE
STRUCTURE
NAME:
SS MH 1
SS MH 2
SSMH3
STRUCTURE DETAILS:
Cylindrical Junction Structure NF
RIM = 585.86
SS 1 INV OUT = 576.100
Cylindrical Junction Structure NF
RIM = 585.44
SS 1 INV IN = 575.420
SS 2 INV OUT = 575.320
Cylindrical Junction Structure NF
RIM = 586.06
SS 2 INV IN = 574.400
PIPES IN:
SS 1, 8"
INV OUT =575.42
SS 2, 8"
INV OUT =574.40
PIPES OUT:
SS 1, 8"
INV OUT =576.10
SS 2, 8"
INV OUT =575.32
NORTHING,
EASTING:
575848.0, 1856583.6
575879.1, 1856567.7
575898.3, 1856524.4
PIPE TABLE
PIPE NAME
SS 1
SS 2
SIZE
in.
LENGTH
ft.
35.0
47.4
SLOPE
1.9%
1.9%
MATERIAL
Sch. 80 PVC Pipe
Sch. 80 PVC Pipe
NOTE:
1. EXISTING AND FINAL SURFACE ELEVATIONS ARE APPROXIMATE.
2. EXISTING UTILITIES WHERE ELEVATION OF PIPES/STRUCTURES ARE AVAILABLE
HAVE BEEN SHOWN ON PROFILE. THESE ARE APPROXIMATE LOCATIONS.
3. PROPOSED UTILITIES WITHOUT KNOW ELEVATIONS ARE SHOWN CALLED OUT
WITH THE APPROXIMATE CROSSING LOCATION BOXED AND HATCHED.
4. INSTALL ROOF DRAIN PIPES ABOVE STORMWATER PIPE AT STRUCTURES.
PROPOSED SURFACEEXISTING SURFACE
CONNECT 8" DI PIPE (SS2)
TO EXISTING STRUCTURE (XSSMH)
PROPOSED SURFACE
EXISTING SURFACE
EXISTING SURFACE
PROPOSED SURFACE
OUTFALL TO EX.
15" STORMWATER PIPE
OUTFALL TO NEW
12" STORMWATER PIPE (P3)
DRAIN TO EX. 8" DUCTILE
IRON PIPE (XSSMH)
CONNECT EX. 6" DUCTILE
IRON PIPE (SSMH1)
CONNECT P2 TO
STRUCTURE SD2
NEW ROOF
DRAIN PIPE
EX. 24" RCP
STORMWATER PIPE
STOP - CAUTION!!!
BEFORE YOU DIG CALL 811 AT LEAST
48 HOURS PRIOR TO CONSTRUCTION
GRAPHIC SCALE
1" = 20'
20'0 40'10'
626A4-21-101 Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
Revisions: Date:
214 Centerview Drive Suite 300
Brentwood, TN 37027…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .