Attachment 22 - 102113 Toilet Compartments.pdf
PDF 32 KB Posted
- Attached to
- Y1DA--626-310 Construct Sleep Disorder Clinic and Specialty Clinics Minor Construction - Murfreesboro
- Solicitation number
- 36C77625B0035
About this file
This is a technical specification document (Section 10 21 13) for toilet compartments as part of a VA construction project to build a sleep disorder clinic and specialty clinic at the TVHS Murfreesboro Campus in Tennessee (VA Project Number 626-310). The specification requires solid polyethylene toilet partitions and urinal screens that are water resistant, graffiti resistant, non-absorbent, contain a minimum 30 percent post-consumer recycled plastic, and have a Class C flame spread rating.
The toilet enclosures must be Type 1, Style B (ceiling hung) with reinforced panels for toilet tissue holders or grab bars, adjustable pivots and hinges, and ADA-compliant latching devices for handicap compartments. Urinal screens must be Type III, Style E (wall hung) measuring 600mm wide by 1060mm high with integral flanges and wall anchor plates. All products must conform to Federal CID A-A-60003 specifications except as modified in the document. Installation requirements include rigid mounting with proper anchoring using expansion bolts for solid masonry/concrete, toggle bolts for hollow walls, and steel bolts for overhead supports. Required submittals include samples, manufacturer's literature, shop drawings at 1/2 scale, and manufacturer's certificates for zinc-coating compliance.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSTRUCT SLEEP DISORDER CLINIC AND SPECIALTY CLINIC
TVHS MURFREESBORO CAMPUS
MURFREESBORO, TN
VA PROJECT NUMBER 626-310
10 21 13 - 1
SECTION 10 21 13
TOILET COMPARTMENTS
PART 1 - GENERAL
1.1 DESCRIPTION
A. This section specifies solid polyethylene toilet partitions, and urinal screens.
1.2 RELATED WORK
A. Section 05 50 00, METAL FABRICATIONS: Overhead structural steel supports for ceiling hung pilasters.
B. FINISH SCHEDULE: Color of toilet partition panels and urinal screens.
C. Section 10 28 00, TOILET, BATH, AND LAUNDRY ACCESSORIES: Grab bars and toilet tissue holders.
1.3 SUBMITTALS
A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT
DATA, AND SAMPLES.
B. Samples: Submit 150 mm (six-inch) square of panel.
C. Manufacturer's Literature and Data: Specified items indicating all hardware and fittings, material, finish, and latching.
D. Shop Drawings: Construction details at 1/2 scale, showing installation details, anchoring and leveling devices.
E. Manufacturer's certificate, attesting that zinc-coatings conform to specified requirements.
1.4 APPLICABLE PUBLICATIONS
A. Publications listed below form a part of this specification to the extent referenced. Publications are referenced in the text by the basic designation only.
B. Federal Specifications (Fed. Spec.):
FF-B-575C...............Bolt, Hexagon and Square
C. Code of Federal Regulations (CFR):
40 CFR 247..............Comprehensive Procurement Guidelines for
Products Containing Recovered Materials
10 21 13 - 2
D. Commercial Item Descriptions (CID):
A-A-1925................Shield, Expansion (Nail Anchors)
A-A-60003...............Partitions, Toilet, Complete
PART 2 - PRODUCTS
2.1 TOILET PARTITIONS
A. Solid polyethylene: water resistant; graffiti resistant; non-absorbent;
contain a minimum 30 percent post-consumer recycled plastic; Class C flame spread rating.
B. Conform to Fed. CID A-A-60003, except as modified herein.
C. Fabricate to dimensions shown or specified.
D. Toilet Enclosures:
1. Type 1, Style B (Ceiling hung).
2. Reinforce panels shown to receive toilet tissue holders or grab bars.
3. Upper pivots and lower hinges adjustable to hold doors open 30 degrees.
4. Latching devices and hinges for handicap compartments shall comply with ADA requirements.
5. Keeper:
a. U-slot to engage bar of throw latch.
b. Combined with rubber bumper stop.
6. Wheelchair Toilets:
a. Upper pivots and lower hinges to hold out swinging doors in closed position.
b. Provide U-type doors pulls, approximately 100 mm (four inches) long on pull side.
E. Urinal Screens:
1. Type III, Style E (wall hung), finish 2 or 3.
a. With integral flanges and continuous, full height wall anchor plate.
b. Option: Full height U-Type bracket.
c. Wall anchor plate drilled for 4 anchors on both sides of screen.
2. Screen 600 mm (24 inches) wide and 1060 mm (42 inches high).
F. Room Entrance Screens: (NOT USED)
2.2 FASTENERS
A. Partition Fasteners: CID A-A-60003.
10 21 13 - 3
B. Use expansion bolts, CID A-A-60003, for anchoring to solid masonry or concrete.
C. Use toggle bolts, CID A-A-60003, for anchoring to hollow masonry or stud framed walls.
D. Use steel bolts FS-B-575, for anchoring pilasters to overhead steel supports.
PART 3 - EXECUTION
3.1 INSTALLATION
A. General:
1. Install in rigid manner, straight, plumb and with all horizontal lines level.
2. Conceal evidence of drilling, cutting and fitting in finish work.
3. Use hex-bolts for through-bolting.
4. Adjust hardware and leave in freely working order.
5. Clean finished surfaces and leave free of imperfections.
B. Panels and Pilasters:
1. Support panels, except urinal screens, and pilaster abutting building walls near top and bottom by stirrup supports secured to partitions with through-bolts.
2. Secure stirrups to walls with two suitable anchoring devices for each stirrup.
3. Secure panels to faces of pilaster near top and bottom with stirrup supports, through-bolted to panels and machine screwed to each pilaster.
4. Secure edges of panels to edges of pilasters near top and bottom with "U" shaped brackets.
C. Urinal Screens:
1. Anchor urinal screen flange to walls with minimum of four bolts both side of panel.
2. Space anchors at top and bottom and equally in between.