Attachment 11 Drawings 8 of 11 Electrical 1 of 3.pdf

PDF 12 MB Posted

Attached to
Y1DA--CON 663-20-102 Upgrade SPS OM Solicitation
Solicitation number
36C26023R0021
Issued by

About this file

This document provides details for a federal solicitation from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 20. The solicitation, numbered 36C26023R0021, seeks proposals for upgrades to the SPS OM system under opportunity Y1DA--CON 663-20-102. Attachment 11 contains electrical drawings as part of the solicitation documentation. Responses are due based on the solicitation requirements for upgrades to the specified SPS OM system for the agency. Relevant details include the solicitation number, opportunity name, type of opportunity, and involved agency.

View the file

Other files

File Type Posted
Attachment 23 Partial Architectural Set.pdf PDF
36C26023R0021 0002.docx DOCX document
Attachment 19 RFI Responses Rev 1.pdf PDF
Attachment 24 RFI Supplement.pptx PPTX presentation
Attachment 15 Wage Determination REV 1 20230825.pdf PDF
Attachment 22 Mobile Steris Trailer.pdf PDF
Attachment 21 Site Visit Agenda and Sign-In.pdf PDF
Attachment 20 36C26022Q0073 RFI List FOR INFORMATIONAL PURPOSES ONLY.pdf PDF
36C26023R0021 0001.docx DOCX document
Attachment 19 RFI Responses.pdf PDF
Attachment 20 36C26022Q0073 RFI List.pdf PDF
Attachment 18 Calculation of Self Performed Work REV 1.pdf PDF
Attachment 14 Drawings 11 of 11 Haz Mat.pdf PDF
Attachment 16 Price Breakout.xlsx XLSX spreadsheet
Attachment 9 Drawings 6 of 11 Mechanical.pdf PDF
36C26023R0021.docx DOCX document
Attachment 8 Drawings 5 of 11 Fire Protection.pdf PDF
Attachment 7 Drawings 4 of 11 Structural.pdf PDF
Attachment 3 Specs 2 of 2.pdf PDF
Attachment 2 Specs 1 of 2.pdf PDF
Attachment 1 Construction SOW Rev5.docx DOCX document
Attachment 13 Drawings 10 of 11 Electrical 3 of 3.pdf PDF
Attachment 10 Drawings 7 of 11 Plumbing.pdf PDF
Attachment 17 Contractor Rules Of Behavior.pdf PDF
Attachment 18 Calculation of Self Performed Work.pdf PDF
Attachment 12 Drawings 9 of 11 Electrical 2 of 3.pdf PDF
Attachment 5 Drawings 2 of 11 Civil.pdf PDF
Attachment 15 Wage Determination.pdf PDF
Attachment 6 Drawings 3 of 11 Architectural.pdf PDF
Attachment 4 Drawings 1 of 11 General.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WALL MOUNTED TELECOMMUNICATIONS OUTLET. 18" AFF UON.

# = INDICATES QUANTITY OF VOICE AND DATA JACKS

COMMUNICATION OUTLETS

FOR ALL TELECOMMUNICATION OUTLETS, ROUTE 3/4" CONDUIT UNDERGROUND IF

NECESSARY AND STUB TO ACCESSIBLE CEILING SPACE WITH CABLING AS

DESCRIBED IN ELECTRICAL SPECIFICATIONS.

# - INDICATES QUANTITY OF VOICE AND DATA JACKS

OUTLET; LETTER INDICATES AS FOLLOWS:

A = AUDIO V = VIDEO I = INTERCOM

OUTLET, TELEVISION

BLANK = 4 11/16" MASTER ANTENNA OUTLET BOX W/BLANK

COVER, MTD. 18" AFF UNLESS OTHERWISE NOTED.

C = CAMERA (CCTV SYSTEM), MTD 18" AFF

M = MONITOR (CTTV SYSTEM).

INTERCOM; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

M-MASTER S-SUBSTATION

E-001 GENERAL NOTES, ABBREVIATIONS AND LEGENDS

ED101 OVERALL LIGHTING DEMOLITION PLAN

ED102 OVERALL POWER AND SPECIAL SYSTEMS DEMOLITION PLAN

ES100 SITE ELECTRICAL PLAN

ES101 OVERALL ELECTRICAL PLAN

EL101 LIGHTING PLAN - NORTH

EL102 LIGHTING PLAN - SOUTH

EP101 POWER PLAN - NORTH

EP102 POWER PLAN - SOUTH

EP103 POWER PLAN - BASEMENT WAREHOUSE

ET101 SPECIAL SYSTEMS PLAN - NORTH

ET102 SPECIAL SYSTEMS PLAN - SOUTH

E-401 ENLARGED DEMOLITION PLANS

E-402 ENLARGED PLANS

E-403 ENLARGED ENERGY PLANT - ELECTRICAL PLAN

E-404 ENLARGED FLOOR PLANS AND SECTION - CART LIFT

E-405 ENLARGED PARTIAL ROOF PLAN

E-501 ELECTRICAL DETAILS

E-502 ELECTRICAL DETAILS

E-601 SCOPE PROCESSING AREA ONE-LINE DIAGRAM - EXISTING

E-602 SCOPE PROCESSING AREA ONE-LINE DIAGRAM - REVISED

E-603 SPS TRAILER ONE-LINE DIAGRAMS

E-604 PARTIAL ONE-LINE DIAGRAM AND LOAD SCHEDULES - CART

LIFT

E-605 ELECTRICAL LOAD SCHEDULES - REVISED

E-606 ELECTRICAL LOAD SCHEDULES - REVISED

E-607 ELECTRICAL SCHEDULES

E-701 OVERALL ELECTRICAL PLAN

E-702 SWING SPACE-LIGHTING AND ELECTRICAL DEMO PLAN

E-703 REVISED LIGHTING AND ELECTRICAL PLAN

E-704 SWING ROOM PARTIAL ONE-LINE DIAGRAMS

E-705 ELECTRICAL LOAD SCHEDULES

S H E E T I N D E X

THIS SHEET IS FOR REFERENCE ONLY AND ALL SYMBOLS, NOTES

AND ABBREVIATIONS MAY NOT APPLY TO THIS PROJECT

SHUNT TRIP PUSHBUTTON OR KEY-SWITCH

PANELBOARD, SWITCHBOARD, OR SWITCHGEAR.

DASHED BOX INDICATES CODE REQUIRED WORKING

CLEARANCE

HARDWIRED CONNECTION

THERMOSTAT

ST

T

VFD VARIABLE FREQUENCY DRIVE

DRAW OUT SWITCH/PLUG-RECEPTACLE CONNECTION

NORMALLY OPEN CONTACT (WHEN DE-ENERGIZED)

NORMALLY CLOSED CONTACT (WHEN DE-ENERGIZED)

E L E C T R I C A L L E G E N D

CONDUIT OR EQUIPMENT TO BE REMOVED

HH

CONDUIT HOME RUN 3/4"C, 2#12 & 1#12 GND. UNLESS

SHOWN OTHERWISE. (EXAMPLE SHOWN: TO PANEL

L1, CIRCUIT 2)

L1-2

CONDUIT HOME RUN - SEE FEEDER SCHEDULE

CONDUIT CONCEALED IN WALL, CEILING, UNDER

FLOOR, IN FLOOR SLAB, OR ROUTED UNDERGROUND

CONDUIT EXPOSED

OVERHEAD ELECTRICAL

EXTRA-HARD USAGE FLEXIBLE CORD

FLEXIBLE CONDUIT

CONDUIT TURNED UP OR TOWARD

CONDUIT TURNED DOWN OR AWAY

CONDUIT CAPPED

CIRCUIT BREAKER, RATING/NO. OF POLES WITH

THERMAL MAGNETIC CIRCUIT BREAKER TRIP, UNLESS

OTHERWISE NOTED

MANUAL OR AUTOMATIC TRANSFER SWITCH.

JUNCTION BOX

HANDHOLE

TRANSFORMER

BATTERY

GROUND ROD IN GROUND ROD BOX

CB

T

ROD SYMBOLS

EXISTING CONDUIT ROUTED UNDERGROUND,

EXISTING TO REMAIN UNLESS OTHERWISE NOTED

##NG

EXISTING CONDUIT EXPOSED, EXISTING TO REMAIN

UNLESS OTHERWISE NOTED

# NEW LUMINAIRE CONTROL. SEE LIGHTING CONTROL

LEGEND LOCATED ON LIGHTING SHEETS.

OS CEILING MOUNTED OCCUPANCY SENSOR(S).

PROVIDE SHOP DRAWINGS OF OCCUPANCY SENSOR

SYSTEM AS PER PROJECT SPECIFICATION AS PART

OF THE SUBMITTAL PROCESS PRIOR TO

COMMENCEMENT OF LABOR. SEE LIGHTING

CONTROL LEGEND LOCATED ON LIGHTING SHEETS.

PE

SWITCH

2 = DOUBLE POLE SWITCH

3 = THREE WAY SWITCH

4 = FOUR WAY SWITCH

K = KEY OPERATED SWITCH

T = SWITCH WITH TIMER

MS = MASTER SWITCH TO CONTROL ALL

FIXED LUMINAIRES IN GUEST UNIT

X

LUMINAIRE, SURFACE

LUMINAIRE, RECESSED

STRIP, SURFACE

HALF SHADED FIXTURE DENOTES: EMERGENCY

LUMINAIRE

LUMINAIRE, WALL MOUNT

LIGHTED EXIT SIGN, ARROW INDICATES DIRECTION

EMERGENCY WALL PACK

LUMINAIRE, POLE MOUNTED

LUMINAIRE, PENDANT MOUNTED

POWER

LUMINAIRES (DIMENSIONS OF SYMBOL WILL VARY DEPENDING ON LUMINAIRE)

LUMINAIRE TYPE IDENTIFICATION: LUMINAIRES INDICATED BY THE FOLLOWING

NOTATIONS:

L# = NEW LUMINAIRE UON, REFER TO LUMINAIRE SCHEDULE FOR DETAILS

U# = NEW LUMINAIRE UON IN DWELLING UNIT, REFER TO LUMINAIRE SCHEDULE FOR

DETAILS

S# = NEW LUMINAIRE UON, EXTERIOR SITE, REFER TO LUMINAIRE SCHEDULE FOR

DETAILS

# = EXISTING LUMINAIRE, UNLESS OTHERWISE NOTED

EL# = EXISTING LUMINAIRE TO BE RELOCATED

EN# = NEW LOCATION OF EXISTING LUMINAIRE

100/3

FLOOR MOUNTED TELECOMMUNICATIONS OUTLET.

# = INDICATES QUANTITY OF VOICE AND DATA JACKS

M

CS

WAP WIRELESS ACCESS PORT

WALL MOUNTED SPEAKER/CLOCK COMBINATION

C WALL CLOCK

CABLE TRAY

RECESSED AUDIO FLOOR BACK BOX, OUTLET AND CONDUITA/V

SPEAKER, CEILING MOUNTED

I = INTERCOM SPEAKER

SPEAKER, WALL MOUNTED, MTD. 7'-6" AFF UON.

RADIO CHANNEL SELECTOR FACILITIES, MTD. 4'-6" AFF UON.

M = SPEAKER PROGRAM SELECTOR SWITCH & VOLUME CONTROL

3-POLE TWIST-LOCK RECEPTACLE FOR MICROPHONE,

MTD. 4'-6" AFF.

REMOTE DICTATING OUTLET MTD 1'-6" AFF. UON.

INTERCOM STATION (REFER TO SPECS. FOR FUNCTIONAL

OPERATION OF INSTRUMENT & TYPE REQUIRED).

S = STAFF STATION

FIBEROPTICS LINE = FO

TELEPHONE LINE = T

COMMUNICATION

LUMINAIRE, DOWNLIGHT

M

M

S

SPECIAL PURPOSE RECEPTACLE, RATING AS

INDICATED

STANDARD RECEPTACLES: 125V, 20A 18" AFF, UON.

TYPES: SIMPLEX /DUPLEX /QUADRUPLEX /FLOOR

DUPLEX /FLOOR QUADRUPLEX

GFCI RECEPTACLES: 125V, 20A 18" AFF, UON. TYPES:

SIMPLEX /DUPLEX /QUADRUPLEX

C = CEILING MOUNTED

S = HALF SWITCHED

I = ISOLATED GROUND

TR = TAMPER RESISTANT

a = LOWER CASE LETTER INDICATES SWITCH

CONTROL

2" = MEASUREMENT INDICATES HEIGHT

ABOVE BACKSPLASH/MILLWORK

A = INDICATES MOUNT ABOVE

BACKSPLASH/MILLWORK. COORDINATE

HEIGHT WITH TRADES.

USB = INDICATES 20A 120V DUPLEX

RECEPTACLE WITH USB CHARGER.

CT = SWITCHED RECEP, INDICATES FULL

CONTROLLED DEDICATED 20A 125V

DUPLEX

CH = SWITCHED RECEP, INDICATES HALF

CONTROLLED DEDICATED 20A 125V

DUPLEX

200AS100AF

M

DISCONNECT SWITCH, FUSED 200=SWITCH RATING,

100=FUSE RATING

DISCONNECT SWITCH, NON FUSED (60A) INDICATES

AMPERAGE RATING

MAGNETIC MOTOR STARTER W/DISCONNECT

MAGNETIC MOTOR STARTER

FVNR = FULL VOLTAGE

NON-REVERSING

FVR = FULL VOLTAGE

00 = NEMA SIZE

UTILITY WATT HOUR METER

60A

M

MOTOR RATED SWITCH. WHERE "M" INDICATED,

PROVIDE A MANUAL MOTOR STARTER W/OVERLOAD

CIRCUIT BREAKER DISCONNECT

(60A) INDICATES AMPERAGE RATING

60A

MOTOR

POWER (CONTINUED)

3 CURRENT TRANSFORMER, NUMBER INDICATES

NUMBER OF C.T.'S

DROP CORD, SINGLE CONVENIENCE OUTLET

X

ELECTRICAL STRIP MOLD

ALARM, TAMPER SWITCH

DETECTION, GAS

C = CARBON DIOXIDE TRANSMITTER

DETECTOR, FLOW SWITCH

DETECTOR, HEAT

DETECTOR, SMOKE

DETECTOR, SMOKE, FOR DUCT

ELECTROMAGNETIC TYPE DOOR HOLDER OUTLET

CITY FIRE ALARM MASTER STATION MTD 5'-6" AFF UNLESS NOTED.

FIRE ALARM TRANSMITTER (BASE LOOP) NUMERALS DENOTE CODE.

FIRE ALARM TROUBLE TRANSMITTER (BASE LOOP) NUMERALS

DENOTE CODE.

KITCHEN HOOD FIRE SUPPRESSION SYSTEM

FIRE SPRINKLER WATER FLOW SWITCH

2-4-6

2-4-6

1. "GENERAL NOTES" APPLY TO ALL ELECTRICAL DRAWINGS. "SHEET NOTES" APPLY TO ONLY THE SHEETS ON WHICH THEY OCCUR. "KEYNOTES"

APPLY ONLY WHERE CALLED OUT.

2. ALL EQUIPMENT SHOWN IN BOLD IS TO BE PROVIDED, OR MODIFIED BY CONTRACTOR UNLESS OTHERWISE NOTED.

3. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE FROM ALL CONTROL DEVICES TO LUMINAIRES FOR CONTROL OF LUMINAIRES SHOWN.

4. LUMINAIRES SHOWN ON DRAWINGS FOR QUANTITY AND CIRCUITING ONLY. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS.

5. ALL FEEDERS AND BRANCH CIRCUITS SHALL CONTAIN AN EQUIPMENT GROUND CONDUCTOR SIZED PER NEC TABLE 250.122. ALL WIRING IS BASED ON CU COPPER PER NEC TABLE 310.15(B)(16), USING 75°C AMPACITIES FOR FEEDERS. IF ALUMINUM IS ALLOWED, CONTRACTOR IS RESPONSIBLE TO RE-SIZE CONDUCTORS AND CONDUIT ACCORDING TO NEC AMPACITIES FOR LOADS SHOWN ON DRAWINGS.

6. BRANCH CIRCUIT CONDUCTORS, NOT OTHERWISE IDENTIFIED SHALL BE A MINIMUM 12 AWG FOR RUNS 70 FEET OR LESS AND A MINIMUM 10 AWG FOR RUNS GREATER THAN 70 FEET. QUANTITY AND SIZE SHALL BE "AS REQUIRED" TO SERVE AND CONTROL DEVICE(S) OR EQUIPMENT WITH A MAXIMUM VOLTAGE DROP OF THREE PERCENT. WHERE CONTRACTOR CHOOSES TO RUN MORE THAN THREE CURRENT CARRYING CONDUCTORS WITHIN ONE RACEWAY OR CABLE, CONDUCTORS SHALL BE INCREASED IN SIZE TO COMPENSATE FOR THE DERATING REQUIRED PER NEC SECTION 310.15. CONDUCTOR AMPACITIES SHALL BE TAKEN FROM THE 75°C COLUMN.

7. MINIMUM CONDUIT IN EXTERIOR AND UNDERGROUND LOCATIONS TO BE 1" UNLESS NOTED OTHERWISE ON PLANS. CONDUITS FROM LUMINAIRES TO LOCAL USER CONTROL DEVICES (SWITCHES, OCCUPANCY SENSORS, ETC.) MAY BE 1/2" OR AS INDICATED IN SPECIFICATIONS.

PROVIDE ADDITIONAL CONDUCTOR FOR UNSWITCHED "HOT" TO LIGHTING LUMINAIRES WITH EMERGENCY POWER BATTERIES OR GENERATOR

TRANSFER DEVICES.

8. WIRING FOR EMERGENCY LIGHTING CIRCUITS OR OTHER EMERGENCY EQUIPMENT SHALL BE KEPT ENTIRELY INDEPENDENT OF ALL OTHER

WIRING AND EQUIPMENT AND SHALL MEET ALL REQUIREMENTS OF NEC SECTION 700.10.

9. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE FOR ALL CIRCUITS SHOWN ON DRAWINGS.

10. WHERE EQUIPMENT PART NUMBERS ARE SHOWN ON THESE PLANS THEY SHALL SUPERCEDE THE REQUIREMENTS OF THE SPECIFICATIONS.

11. ALL CONDUITS SHALL BE CONCEALED UNLESS OTHERWISE NOTED.

12. COORDINATE EXACT LOCATION OF ALL OUTLETS, COMBINATION CLOCK/SPEAKERS, SPEAKER, FA DEVICES, ETC., WITH THE ARCHITECTURAL

ELEVATIONS PRIOR TO COMMENCING WORK.

13. COORDINATE USE OF CEILING SPACE WITH ALL TRADES PRIOR TO COMMENCING WORK. MANY AREAS ARE VERY CONGESTED AND REQUIRE

CLOSE COORDINATION.

14. COORDINATE INSTALLATION REQUIREMENTS FOR OCCUPANCY SENSOR LIGHTING CONTROL WITH THE MANUFACTURER. PROVIDE ALL APPURTENANCES AS REQUIRED BY THE MANUFACTURER. PROVIDE ADDITIONAL SENSORS WHERE NECESSARY TO PROVIDE COMPLETE

COVERAGE IN EACH ROOM CONTROLLED BY OCCUPANCY SENSORS.

15. COORDINATE THE INSTALLATION OF ALL EXTERIOR OUTLET BOXES WITH THE TYPE OF MASONRY IN EACH AREA. CUT ALL FLUTED BLOCKS SO THAT THE BOX IS INSTALLED FLUSH. SEE ARCHITECTURAL DETAILS FOR MOUNTING REQUIREMENTS.

16. SEAL ALL CONDUIT PENETRATIONS OF FLOORS & FIRE RATED ASSEMBLIES WITH U.L. APPROVED MATERIALS AND METHODS TO MAINTAIN FIRE RATING. PROTECT ALL OPENINGS FOR STEEL ELECTRICAL BOXES IN FIRE RATED WALLS WITH U.L. APPROVED MATERIALS AND METHODS TO

MAINTAIN THE FIRE INTEGRITY.

17. PROVIDE ADDITIONAL CONDUIT SLEEVES THROUGH WALLS WHERE REQUIRED FOR ROUTING OF SIGNAL SYSTEM WIRING NOT REQUIRED TO BE RUN IN CONDUIT. EACH SLEEVE SHALL BE DEDICATED TO EACH SIGNAL SYSTEM. SLEEVES ROUTED THROUGH RATED WALLS SHALL BE

SEALED WITH U.L. MATERIALS AND METHODS TO MAINTAIN FIRE RATING OF WALL.

18. SEE MECHANICAL/PLUMBING DRAWINGS AND SUBMITTALS FOR EXACT LOCATIONS AND ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR TO

INSTALLATION.

19. ALL LOW VOLTAGE SYSTEMS NOT RUN IN CONDUIT SHALL HAVE MINIMUM 3/4"C. ROUTED FROM THE DEVICE THROUGH WALLS INTO THE ACCESSIBLE CEILING SPACE. NO CABLING SHALL BE ROUTED IN THE WALLS OR INACCESSIBLE LOCATION WITHOUT CONDUIT.

20. GFI RECEPTACLES ARE REQUIRED WITHIN 6 FT OF ALL SINKS, ON THE EXTERIOR BELOW 8 FT FROM THE FINISH FLOOR, AND ON ALL ROOFS.

21. UNLESS SPECIFICALLY SHOWN ON THESE PLANS NO STRUCTURAL MEMBER SHALL BE CUT, NEITHER DRILLED NOR NOTCHED WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE STRUCTURAL ENGINEER AND THE DIVISION OF THE STATE ARCHITECT.

G E N E R A L N O T E S

"a"

"NL"

"E"

INDICATES PANELBOARD AND CIRCUIT PROVIDING

POWER TO LUMINAIRES IN SAME ROOM/AREA, UON.

INDICATES TYPE PER LUMINAIRE SCHEDULE.

(SEE "LUMINAIRES" LEGEND ON THIS SHEET FOR MORE

INFORMATION)

INDICATES NIGHT LIGHT LUMINAIRE.

INDICATES CONTROL PER SWITCH.

INDICATES POWER TO EMERGENCY LIGHTING

CONTAINED IN SAME ROOM/AREA.

#ENLa

PNL-2

INDICATES CIRCUIT NUMBER.

INDICATES POWER SOURCE."PNL"

"2"

RECEPTACLE, TYPICAL:

LUMINAIRE, TYPICAL:

X-Xa/E

X-XE

X-Xa

X-X

CIRCUIT DESIGNATION

DETAIL/PLAN1

SCALE

SECTION

A

XXX

A

XXX

XXX

FIGURE OR PHOTO

DETAIL NUMBER

IF PHOTO, ARROW

DENOTES DIRECTION

TAKEN

DETAIL AREA

SHEET ON WHICH

SECTION APPEARS

SECTION LETTER

SHEET WHERE

SECTION IS TAKEN

FROM

SECTION LETTER

DETAIL/PLAN NUMBER

XXX

DETAIL NUMBER

SHEET ON WHICH

DETAIL APPEARS

SHEET WHERE DETAIL

IS TAKEN FROM

FAULT CURRENT

TAG (AIC)

KEY NOTE

G E N E R A L S Y M B O L S

XX

NURSE'S CALL MASTER STATION MTD ON NURSE'S COUNTER TOP UNLESS OTHERWISE

NOTED.

NURSE CALL TERMINAL CABINET.

NURSE CALL STATION.

1 = SINGLE PATIENT STATION. MTD 4'-0" AFF UNLESS OTHERWISE NOTED

2 = DUPLICATE PATIENT STATIONS (SEPARATE INDICATORS AT MASTER

STATION) MTD 5'-0" AFF UNLESS OTHERWISE NOTED

D = DUTY STATION. MTD 5'-0" AFF UNLESS OTHERWISE NOTED

E = STATION MTD 6'-0" AFF FOR SHOWER LOCATION, MTD 4'-6" AFF FOR TUB

LOCATION, & MTD 3'-0" AFF FOR TOILET LOCATION, UON

P = PSYCHIATRIC CORRIDOR STATION WITH KEY SWITCH

S = AUDIO VISUAL WALL STATION (STAFF) MTD 5'-0" AFF UNLESS

OTHERWISE NOTED

U = UTILITY CALL STATION, MTD 5'-0" AFF UNLESS OTHERWISE NOTED

EM = EMERGENCY STATION, MTD 5'-0" AFF UNLESS OTHERWISE NOTED

J = JACK STATION. MTD 4'-0" AFF UNLESS OTHERWISE NOTED

NURSE CALL STATION.

2 = NURSE'S CALL DOME LIGHT (SUFFIX INDICATES No OF LAMP) MTD 6" ABOVE DOOR.

D = CORRIDOR DOME LIGHT.

I = AUXILIARY INTERSECTIONAL DOME LIGHT.

NIGHT LIGHT

PATIENT BED OUTLET

POWER SUPPLY WITH BATTERY BACKUP

NURSE CALL

FIRE ALARM

ALARM, FIRE, COMMUNICATOR

ALARM, FIRE, PANEL; LETTERS INDICATE AS FOLLOWS:

FACC = CENTRAL CONSOLE FACP = CONTROL PANEL

MFACP= MASTER CONTROL PANEL FAAP = ANNUNCIATOR PANEL

REMOTE ANNUNCIATOR

ADDRESSABLE RELAY

ALARM, FIRE; LETTERS INDICATE AS FOLLOWS:

BATT = BATTERIES CHR = CHARGER FAR = RECORDER

ALARM, FIRE, TERMINAL CABINET.

ALARM, TRANSPONDER OR TRANSMITTER

ALARM, FIRE, MANUAL PULL STATION

C = WITH CLEAR PLASTIC COVER

ALARM, HORN/LIGHT, ONE ASSEMBLY

C = WITH CHIME

ALARM, HORN/LIGHT, SEPARATE ASSEMBLY

ALARM, LAMP LIGHT, SIGNAL LIGHT, STROBE

ALARM, MANUAL CONTROL

ALARM, MINI HORN

C

SAFETY AND SECURITY

M = MOUNTING FOR ALL SAFETY AND SECURITY SYMBOLS:

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

SECURITY ACCESS, ANNUNCIATOR PANELAP

SECURITY ACCESS, VIDEO CAMERA WITH LENS

SECURITY ACCESS, DOME CAMERA

M T

AUDIO DEVICE; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

B-BELL C-CHIME H-HORN K-KLAXON

L-LISTEN-IN M-MICROPHONE S-SOUNDER S-SPEAKER Z-BUZZER

M KEYPAD DEVICE

M CARD READER WITH KEYPAD

M T

CARD ACCESS READER; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

B-BARCODE F-ELEVATOR FLOOR CALL H-ELEVATOR HALL CALL

M-MAG STRIP P-PROXIMITY S-SMART CARD T-TOKEN

M T

ELECTRONIC LOCK; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

D-DEADBOLT H-HYBRID L-LATCH SET M-MAGNETIC S-STRIKE

M T

PUSH BUTTON; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

M T

DOOR CONTACT

PB PULL BOX

J

CONDUIT & WIRE TAG

(REFER TO CONDUIT

AND WIRE SCHEDULE)

XXXNG

RECEPTACLE ON EMERGENCY POWER: 125V, 20A

18"AFF, UON. TYPES: DUPLEX / QUADRAPLEX /

SPECIAL

C

MOTION DETECTOR; LETTER INDICATES AS FOLLOWS:

T=TECHNOLOGY/TYPE

D-DUAL TECHNOLOGY IR-INFRARED M-MICROWAVE U-ULTRASONIC

2-GANG COMPARTMENT BOX IN FLOOR FOR DATA,

AND RECEPTACLE

C

TELECOMMUNICATIONS SYSTEMS BONDING BUSBARTGB

PS

B

FS

D

M

FTR

FATC

BATT

R

FACC

FAC

A

N

N

NCT

NCS

FTT

DH

FAT

HD

TS

K

F

R

R

S

S

A B B R E V I A T I O N S

AFC

AFG

AF

AFCI

AFF

AI

AIC

AHJ

AO

ATS

C

CATV

CB

CCTV

CL

CO

DDC

DI

DO

DP

DPM

EC

EL

EM

EN

EMT

ER

EX

FAAP

FACP

FCIO

FOIC

GFCI

GFP

GND

HTR

IG

IMC

JBOX

LCP

MCA

MCB

MCC

MDP

MLO

MS

MTD

MTS

NAC

NEC

NFC

NIC

NL

NTS

OC

OH

OS

PIV

PNL

PS

PVC

R

RCPT

RMC

SAC

SB,SWBD

SG

SPD

TEL

TR

TYP

UC

UON

UL

UG

VD

VFD

W

WP

XFMR

AVAILABLE FAULT CURRENT

ABOVE FINISHED GRADE

AMP FRAME

ARC FLASH CIRCUIT INTERRUPTER

ABOVE FINISHED FLOOR

ANALOG INPUT

AMPERE INTERRUPTING CAPACITY

AUTHORITY HAVING JURISDICTION

ANALOG OUTPUT

AUTOMATIC TRANSFER SWITCH

CONDUIT OR CEILING

CABLE TELEVISION

CIRCUIT BREAKER

CLOSED CIRCUIT TELEVISION

CONNECTOR LIGHTING

CONDUIT ONLY

DIRECT DIGITAL CONTROLS

DISCRETE INPUT

DISCRETE OUTPUT

DISTRIBUTION PANELBOARD

DIGITAL POWER METER

ELECTRICAL CONTRACTOR

EXISTING TO BE RELOCATED

EMERGENCY

EXISTING IN NEW LOCATION

ELECTRICAL METALLIC TUBING

EXISTING TO REMAIN

EXISTING

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FURNISHED BY CONTRACTOR, INSTALLED

BY OWNER

FURNISHED BY OWNER, INSTALLED BY

CONTRACTOR

GROUND FAULT CIRCUIT INTERRUPTER

GROUND FAULT PROTECTION

GROUND

HEATER

ISOLATED GROUND

INTERMEDIATE METALLIC CONDUIT

JUNCTION BOX

LIGHTING CONTROL PANEL

MINIMUM CIRCUIT AMPACITY

MAIN CIRCUIT BREAKER

MOTOR CONTROL CENTER

MAIN DISTRIBUTION PANEL

MAIN LUGS ONLY

MOTOR STARTER

MOUNTED

MANUAL TRANSFER SWITCH

NOTIFICATION APPLIANCE CABINET

NATIONAL ELECTRICAL CODE

NOT FOR CONSTRUCTION

NOT IN CONTRACT

NIGHT LIGHT

NOT TO SCALE

ON CENTER

OVERHEAD

OCCUPANCY SENSOR

POST INDICATOR VALVE

PANEL

POWER SUPPLY

POLYVINYL CHLORIDE

EXISTING TO BE REMOVED

RECEPTACLE

RIGID METAL CONDUIT

SMALL APPLIANCE CIRCUIT

SWITCHBOARD

SWITCHGEAR

SURGE PROTECTIVE DEVICE

TELEPHONE

TAMPER RESISTANT

TYPICAL

UNDER COUNTER

UNLESS OTHERWISE NOTED

UNDERWRITERS LABORATORIES

UNDERGROUND

VOLTAGE DROP

VARIABLE FREQUENCY DRIVE

WEATHERPROOF (WHILE IN USE)

WEATHERPROOF

TRANSFORMER

EQUIPMENT DESIGNATIONS

PHOTO ELECTRIC SENSOR

A.T.S.

PANEL DESIGNATIONS

VOLTAGE (4=480V, 2=208V)

SYSTEM (N=NORMAL, E=LIFE SAFETY,

C=LIFE SUPPORT, Q=EQUIPMENT)

R=XRAY, K=KITCHEN, E=ELEVATOR,

(IF USED)

RISER CLOSET (A THRU E D&T BUILDING

F&G NURSING TOWER

H NURSING HOME

J ENERGY PLANT

K THERAPY GYM)

FLOOR

UNIT SUBSTATION

ENERGY PLANT

D & T BUILDING

NURSING TOWER, NURSING HOME

DISTRIBUTION PANEL DESIGNATION:

NUMBER SUPPLIED FROM UNIT SUBSTATION OR RISER

CLOSET DESIGNATION

UNIT SUBSTATION

SYSTEM (SEE PANEL DESIGNATION)

MCC DESIGNATION

NUMBER SUPPLIED FROM UNIT SUBSTATION

UNIT SUBSTATION

SYSTEM (SEE PANEL DESIGNATION)

AUTOMATIC TRANSFER SWITCH DESIGNATION

NUMBER SUPPLIED FROM UNIT SUBSTATION

UNIT SUBSTATION

SYSTEM (SEE PANEL DESIGNATION)

A =

B =

C =

XXXX

XXXX-X

XXXXXX

XX-X

WIRELESS TRACKING MODULE, IR TECHNOLOGY

VW - INDICATES VIRTUAL WALL TYPEVW

WT

PRESSURE DEVICE

PRESSURE BEACONP

B-BELL PUSH D-DURESS P-PANIC R-DOOR OPENER

X-REQUEST-FOR-EXIT

EMERGENCY STOP PUSHBUTTONE

BUS DUCT

LOW VOLTAGE SWITCH. NUMBER OF BUTTONS PER SWITCHING

ZONES SHOWN. AUTO-OFF VIA OCCUPANCY SENSOR, AS

SHOWN. PROVIDE LIGHTING PACK(S) IN ACCESSIBLE CEILING

SPACE AS NECESSARY.

# = 3 OR 4 FOR 3-WAY/4-WAY CONDITIONS

a = SWITCHING ZONE

LINE VOLTAGE WALL OCCUPANCY SENSOR.

a = SWITCHING ZONE

LINE VOLTAGE MANUAL TOGGLE SWITCH.

LOW VOLTAGE DIMMER SWITCH. NUMBER OF DIMMER

SWITCHES PER SWITCHING ZONES SHOWN. AUTO-OFF VIA

OCCUPANCY SENSOR, AS SHOWN. PROVIDE LIGHTING PACK(S)

IN ACCESSIBLE CEILING SPACE AS REQUIRED.

# = 3 OR 4 FOR 3-WAY/4-WAY CONDITIONS

a = SWITCHING ZONE

ALL INTERIOR AREAS TO HAVE MANUAL ON/AUTO OFF LIGHTING

CONTROL WITH THE USE OF DUAL TECHNOLOGY OCCUPANCY

SENSORS. EXCEPT WHERE A WALL SWITCH OCCUPANCY

SENSOR IS NOTED.

SENSORS TO BE CEILING MOUNTED. VERIFY LAYOUT WITH

VENDOR SHOP DRAWINGS PRIOR TO PLACEMENT. ADDITIONAL

LIGHTING PACK(S) SHALL BE PROVIDED FOR ROOMS WITH

CONTROLLED RECEPTACLES.

1#

OS

a a a

4a

L I G H T I N G C O N T R O L S C H E D U L E

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

E-001

GENERAL NOTES, ABBREVIATIONS

AND LEGENDSSPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL JPS/FEB

100% CD

Revisions: Date:

DROP CORD, DATA JACK

# = QUANTITY OF DATA JACKS

C

C = CEILING MOUNTED

I

AC AUDIO/VISUAL CONTROLLER AND INPUT DEVICE

T

ELECTRICAL

BD-110

EXISTING

BUSDUCT

EXISTING

STERILIZER

TRANSFORMER

EXISTING

BDE4

EXISTING

BDN4

EXISTING

BDQ4

EXISTING

T3

EXISTING

BDQ2

EXISTING

BDN2/H

EXISTING

BDE2

EXISTING

BDN2.2

EXISTING

BDN2.12

BUSDUCT

T2

EXISTING TRANSFORMER 1

T9

EXISTING TRANSFORMER 2

EXISTING

EXISTING

18 SF

SIGNAL

BD-110B 20 SF

TELE

BD-110A

MRV-24

ACP-1

MRV-3 MRV-2

EXISTING EXISTING EXISTING

EXISTING

D & T NORTH

NURSING

TOWER

AREA SHOWN

CENTRAL CORE

NORTH

CENTRAL CORE

SOUTH

CENTRAL CORECENTRAL CORE

SE

152-0

SE

152-10

ENLARGED RM BD-110A AND BD-110B DEMOLITION PLAN ENLARGED RM BD110 MEZZANINE DEMOLITION PLAN

EXISTING DATA RACKS TO BE UTILIZED FOR ALL DATA

CONNECTIONS FOR RENOVATED AREAS. REFERENCE

SHEETS ET101 AND ET102 FOR ADDITIONAL INFORMATION.

MODIFY/ADD TO EXISTING DATA RACK AND EQUIPMENT AS

REQUIRED TO PROVIDE A COMPLETE AND FULLY

FUNCTIONAL SYSTEM. FOR BIDDING PURPOSES,

CONTRACTOR SHALL ASSUME (4) NEW (1) RU, 48-PORT, CAT

6A PATCH PANELS AND THEIR APPURTENANCES ARE

REQUIRED.

1. ALL ELECTRICAL WORK SHALL BE CLOSELY COORDINATED

WITH THE CONTRACTORS PHASING OF THE PROJECT.

COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER

TRADES.

2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY.

CONTRACTOR SHALL FIELD VERIFY ALL POWER AND SIGNAL

DEVICES AND ASSOCIATED CIRCUITRY AS REQUIRED. ALL

RACEWAYS AND CONDUCTORS ASSOCIATED WITH

DEMOLISHED EQUIPMENT SHALL BE DEMOLISHED BACK TO

THEIR SOURCE, UNLESS OTHERWISE NOTED.

3. ALL DEMOLITION OF ELECTRICAL SYSTEMS SHALL BE CLOSELY

COORDINATED WITH THE CONTRACTORS PHASING OF THE

PROJECT. VERIFY DEMOLITION OF ELECTRICAL WITH ALL

TRADES PRIOR TO START OF DEMOLITION.

4. PROTECT ALL EXISTING WORK FROM DAMAGE DURING

CONSTRUCTION. ANY DAMAGED MATERIALS, SYSTEMS,

COMPONENTS, FINISHES AND THE LIKE, SHALL BE REPAIRED

OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE

ACCEPTANCE OF THE OWNER.

5. ALL CIRCUITS AND RELATED DEVICES THAT ARE TO REMAIN

ARE TO STAY "ENERGIZED" IN THE DEMOLITION AND NEW

CONSTRUCTION PHASES UNTIL THE COMPLETION OF THE

WORK INDICATED ON THESE PLANS.

6. CONTRACTOR SHALL DISPOSE OF THE REMOVED DEVICES.

DISPOSAL OF DEVICES SHALL COMPLY WITH ALL

APPROPRIATE CODES. REUSE EXISTING CONDUITS AND

JUNCTION BOXES WHERE NOTED AS IS PRACTICAL.

7. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL

DIRECTORIES FOR ALL PANELS THAT CONTAIN CIRCUITS

IMPACTED BY THIS PROJECT.

SCALE : NTS

NOT USED1

GENERAL NOTES

KEY NOTES (THIS SHEET ONLY)

KEY PLAN

SCALE : 1/2" = 1'-0"

ENLARGED RM BD-110 DEMOLITION PLAN2

SCALE : 1/2" = 1'-0"

SCALE : 1/2" = 1'-0"

0 1' 2' 4' 0 1' 2' 4'

0 1' 2' 4'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL/WNM JPS/FEB

100% CD

Revisions: Date:

E-401

ENLARGED DEMOLITION PLANS

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

EXISTING PANEL TO BE REVISED. REFERENCE APPROPRIATE

PANEL SCHEDULE FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text

230 SF

CONFERENCE

B102

OS

OS

103 SF

RME COOP/SPD SEC.

B101

230 SF

CONFERENCE

CB-15D

G22

BDE4-3

G22

BDE4-3

G22

BDE4-3

G22

BDE4-3

G22

BDE4-3

G22

BDE4-3

G23

BDE4-3

G23

BDE4-3

BUSDUCT

T2

EXISTING TRANSFORMER 1

T9

EXISTING TRANSFORMER 2

EXISTING

EXISTING

18 SF

SIGNAL

BD-110B 20 SF

TELE

BD-110A

MRV-24

ACP-1

MRV-3 MRV-2

EXISTING EXISTING EXISTING

EXISTING

D & T NORTH

NURSING

TOWER

AREA SHOWN

CENTRAL CORE

NORTH

CENTRAL CORE

SOUTH

CENTRAL CORECENTRAL CORE

C

S

S

S

C

230 SF

B102

103 SF

B101

AC BDN2.2-50

BDN2.2-50

BDN2.2-50

BDN2.2-50

BDN2.2-50BDN2.2-50

ELECTRICAL

BD-110

EXISTING

BDN2/H

EXISTING

BDE2

BDN2.2BDN2.1

EXISTING

BUSDUCT

EXISTING

STERILIZER

TRANSFORMER

BDE4

EXISTING

BDN4 BDQ4 T3

BDQ2

ENLARGED RM BD-110A AND BD-110B ELECTRICAL PLAN ENLARGED RM BD110 MEZZANINE PLAN

RECEPTACLE AND DATA OUTLET FOR CEILING MOUNTED

PROJECTOR. COORDINATE FINAL LOCATION WITH OWNER.

REFERENCE ONE-LINE DIAGRAM AND PANEL SCHEDULES

FOR POWER DISTRIBUTION CONNECTIONS.

EXISTING DATA RACKS TO BE UTILIZED FOR ALL DATA

CONNECTIONS FOR RENOVATED AREAS. REFERENCE

SHEETS ET101 AND ET102 FOR ADDITIONAL INFORMATION.

MODIFY/ADD TO EXISTING DATA RACK AND EQUIPMENT,

INCLUDING BUT NOT LIMITED TO PATCH PANELS, AS

REQUIRED TO PROVIDE A COMPLETE AND FULLY

FUNCTIONAL SYSTEM.

AUDIO/VISUAL CONTROLLER AND INPUT DEVICE, PROVIDE

COMPLETE AND FULLY FUNCTIONAL AUDIO SYSTEM,

AUDIO SYSTEM SHALL INTEGRATE WITH OVERHEAD

PROJECTOR AND SPEAKER SYSTEM. COORDINATE WITH

A/V CONTRACTOR AND ARCHITECT FOR FINAL

INSTALLATION LOCATIONS.

PACS CARD READER ACCESS CONTROL PANEL, 8-CARD

READER PANEL. PROVIDE RACEWAY AND CABLING TO

CONNECT NETWORK CABLING FROM ACCESS CONTROL

PANEL AND VA NETWORK SWITCH LOCATED IN NEARBY

DATA RACK. REFERENCE SPECIFICATION 281300 AND KEY

NOTE '3' ON THIS SHEET FOR ADDITIONAL INFORMATION.

COORDINATE ALL VA NETWORK CONNECTIONS WITH VA

COR.

REVISED PANEL. REFERENCE APPROPRIATE PANEL

SCHEDULE FOR ADDITIONAL INFORMATION.

1. ALL ELECTRICAL WORK SHALL BE CLOSELY COORDINATED

WITH THE CONTRACTORS PHASING OF THE PROJECT.

COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER

TRADES.

2. MAKE ALL CONNECTIONS TO EQUIPMENT PER

MANUFACTURER'S REQUIREMENTS.

3. ROUTE ALL CONDUIT HOME RUNS TO PANELS OVERHEAD AND

ABOVE ACCESSIBLE CEILINGS WHERE AVAILABLE.

4. PROVIDE POWER RELAYS, LOW VOLTAGE TRANSFORMERS,

CONDUIT AND JUNCTION BOXES FOR FIRE ALARM AND

TELECOMMUNICATION SYSTEMS AS REQUIRED.

5. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL

DIRECTORIES FOR ALL PANELS THAT CONTAIN CIRCUITS

IMPACTED BY THIS PROJECT.

6. COORDINATE WITH OWNERS AGENT FOR FINAL LOCATIONS OF

ALL DATA PORTS AND SPECIAL CONNECTIONS FOR

EQUIPMENT PRIOR TO ROUGH-IN. COORDINATE RECEPTACLE

INSTALLATION WITH MILLWORK AND BACKSPLASH INSTALLERS

TO AVOID INTERFERENCES.

7. ELECTRICAL POWER AND TELECOMMUNICATIONS

CONTRACTOR SHALL BE RESPONSIBLE TO REVIEW EACH

OTHER'S DRAWING AND SUBMITTALS AND COORDINATE FOR

FULLY OPERATIONAL SYSTEM.

8. COORDINATE MOUNTING HEIGHTS AND ORIENTATION OF

DEVICES IN MILLWORK WITH ARCHITECTURAL ELEVATIONS.

9. PROVIDE MODIFICATIONS TO THE EXISTING FIRE ALARM

SYSTEM TO SUPPORT THE ADDED FIRE ALARM FIELD DEVICES

AS REQUIRED. PROVIDE ADDITIONAL I/O CARDS/MODULES,

EQUIPMENT, CONNECTIONS, AND APPERTENANCES AS

REQUIRED TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL

SYSTEM. CONTRACTOR SHALL COORDINATE ALL FIRE ALARM

WORK WITH VA PRIOR TO INITIATING WORK.

SCALE : 1/4" = 1'-0"

ENLARGED RM B101 & B102 LIGHTING PLAN1

GENERAL NOTES

KEY NOTES (THIS SHEET ONLY)

KEY PLAN

SCALE : 1/2" = 1'-0"

ENLARGED RM BD-110 ELECTRICAL PLANS2

SCALE : 1/2" = 1'-0"

-SCALE : 1/2" = 1'-0"

SCALE : 1/4" = 1'-0"SCALE : 1/4" = 1'-0"

ENLARGED RM B101 & B102 POWER AND SPECIAL SYSTEMS PLAN5

0 1' 2' 4'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL/WNM JPS/FEB

100% CD

Revisions: Date:

E-402

ENLARGED PLANS

PROJECT

NORTH

0 1' 2' 4'

PROJECT

NORTH

0 1' 2' 4'

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

0 2' 4' 8'

0 2' 4' 8'

ACCESS CONTROL PANEL

BDE2-39

ACCESS CONTROL PANEL

BDE2-39

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text J

AutoCAD SHX Text J

AutoCAD SHX Text J

SU

PP

LY

W

AR

EH

OU

SE

BR

EA

K

OF

FI

CE

CO

RR

ID

OR

EN

CL

OS

UR

E

FO

R

BU

LK

O

XY

GE

N

ST

OR

AG

E

TA

NK

P

H

ST

OR

AG

E

CY

LIN

DE

R

ST

OR

AG

E

M

ED

IC

AL

G

AS

RO

OM

M

EC

HA

NI

CA

L

M .E

.R

#4

VE

ST

IB

UL

E♦♦♦♦♦♦♦♦♦

TRANSFORMERS AND

SWITCHGEAR ROOM

COMPRESSOR ROOM

REACTOR ROOM

GENERATOR

EMERGENCY

PIT

STAIR #11

TO

ILE

T

MAL

E

EMERGENCY SWITCHGEAR

CH

ILL

ER

RO

OM

ENGINEERING

CONTROL RM

BO

ILE

R R

OOM

GRO

UN

DS

C

RE

W

INDUSTRIAL

STAIR #17

INDUSTRIAL

STAIR #22

SHOWER

MALE LOCKERS/

TR

AN

SP

ORT

AT

IO

N

CA

GE

TR

AN

SP

ORT

AT

IO

N

OFFICE

FL

OOR C

RA

TE

CO

VE

R O

VE

R P

IT

E

CONTINUE TO SPS TRAILER

DISCONNECTS

(SEE DRAWING ES100)

D & T NORTH

NURSING

TOWER

AREA SHOWN

SWITCH BOARD "SWBD-AN-1".

EXISTING SPARE CIRCUIT BREAKER "AL3" TO BE UTILIZED FOR NEW FEEDER.

1. REFERENCE ONE-LINE DIAGRAM ON SHEET E-603, DETAIL "1", FOR ALL

CONDUIT AND WIRE SIZING.

SCALE : 1/8" = 1'-0"

ENLARGED ENERGY PLANT - ELECTRICAL PLAN1

0 4' 8' 16'

TRUE

NORTH

GENERAL NOTES

KEY NOTES (THIS SHEET ONLY)

E-403

ENLARGED ENERGY PLANT -

ELECTRICAL PLAN

KEY PLAN

ENERGY

PLANT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL JPS/FEB

100% CD

Revisions: Date:

LEVEL 1

0' - 0"

LEVEL BASEMENT

-18' - 0"

LEVEL BASEMENT

- INTERSTITIAL

-7' - 11"

LEVEL 7

126' - 0"

PENTHOUSE

LEVEL

153' - 0"

'-9

LEVEL 3'

36' - 0"

6' -0

6' -0

NEW CART LIFT

ROOF

172' - 0"

LEVEL 8

144' - 0"

9' -0

9' -6

E-404

S-5

UPDN

UP

EXISTING LINEN CHUTESPD LIFT SHAFT

T-13

SOILED

RETURN

T-14

CLEAN

SUPPLY/

RETURN

ELEVATOR MACHINE ROOM

P8QE4

P8N4

8N2.1

8Q2.1

T-13

SOILED

RETURN

T-13 CAB LTG DISC

8N2-1-7

T-13 CONTROL

SWITCH

P8N4-3

AC-11A

L2E 8N2-1-9

L2 8N2-1-9

L2 8N2-1-9

D & T

TRUE

NORTH

CENTRAL CORE

NORTH

NURSING

TOWER

AREA SHOWN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

E-404

ENLARGED FLOOR PLANS AND

SECTION - CART LIFTSPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL JPS/FEB

100% CD

1/4" = 1'-0"

CART LIFT T-13 MACHINE ROOM ELECTRICAL PLAN

1/4" = 1'-0"

3 CART LIFT T-13 SHAFT SECTION VIEW

Revisions: Date:

1/4" = 1'-0"

CART LIFT T-13 MACHINE ROOM DEMOLITION PLAN

PROJECT

NORTH

KEY NOTES (THIS SHEET ONLY)

GENERAL NOTES

KEY PLAN

EXISTING ELECTRICAL POWER AND CONTROL EQUIPMENT AND ALL ASSOCIATED

CONDUIT AND WIRE TO BE DEMOLISHED.

ALL EXISTING CART LIFT EQUIPMENT, INCLUDED MOTOR-GENERATOR AND

OPERATOR SHALL BE DEMOLISHED. ALL EQUIPMENT LOCATIONS NOT SHOWN

FOR CLARITY; CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS AS

REQUIRED.

T-13 CART LIFT CONTROL UNIT.

CART LIFT EQUIPMENT OPERATOR AND RELATED EQUIPMENT. EQUIPMENT

LOCATIONS NOT SHOWN FOR CLARITY; CONTRACTOR SHALL COORDINATE WITH

MANUFACTURER AS REQUIRED FOR EXACT LOCATION.

EXISTING PANELBOARDS TO BE REVISED. REFERENCE ONE-LINE DIAGRAM ON

SHEET E-604 FOR ADDITIONAL INFORMATION.

REPLACE EXISTING DUPLEX RECEPTACLE WITH NEW GFCI, WR, TR, 20A, 120V

RECEPTACLE WITH WHILE-IN-USE COVER.

1. COORDINATE EXACT CART LIFT T-13 EQUIPMENT LAYOUT WITH CART LIFT

MANUFACTURER AS REQUIRED.

2. ALL FIRE ALARM DEVICES SHALL BE CONNECTED TO THE EXISTING FIRE

ALARM SYSTEM. IF REQUIRED, PROVIDE ADDITIONAL INPUT CARDS FOR THE

FIRE ALARM CONTROL PANEL.

3. REFERENCE ONE-LINE DIAGRAM ON SHEET E-604 FOR ADDITONAL

CIRCUITING INFORMATION.

PROJECT

NORTH

DN

ROOF LEVEL

ELE 172'-0"

LAUNDRY CHUTE VENT

EXISTING TRAFFIC PADS

EXISTING MAINTENENCE

EQUIPMENT HOLD DOWN

8N2-1-7

HP-11

8N2-1-9,11

D & T

NORTH

CENTRAL CORE

NORTH

NURSING

TOWER

AREA SHOWN

E-405

ENLARGED PARTIAL ROOF PLAN

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

Revisions: Date:

ENLARGED PARTIAL ROOF PLAN

PROVIDE LOCAL DISCONNECT AND RECEPTACLE ON ADJACENT

STAINLESS-STEEL RACK UTILIZING STAINLESS STEEL FASTENING HARDWARE

AS REQUIRED.

GENERAL NOTES

KEY NOTES (THIS SHEET ONLY)

KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL JPS/FEB

100% CD

Revisions: Date:

1. COORDINATE FINAL EQUIPMENT LOCATIONS WITH MECHANICAL AND

ARCHITECTURAL DRAWINGS.

SCALE : 1/4" = 1'-0"-

PROJECT

NORTH

GROUNDING ELECTRODE AND BONDING SYSTEM1

- SCALE: NTS

ITEM

CONCRETE ENCASED REBAR (UFER)

GROUND RODS (IF WITHOUT GROUND RING)

GROUND RING (WITH OR WITHOUT GROUND RODS AS NOTED)

SIZE

METAL WATER PIPES

OTHER CONNECTIONS AS NOTED ON PLANS

STRUCTURAL STEEL

SPECIAL SYSTEMS GROUNDING BUS BARS

POWER CABLE TRAY, SPECIAL SYSTEMS CABLE TRAY

#3/0 #6

#2

#3/0 #6

#3/0 #2

GAS PIPES

GROUNDING ELECTRODE AND BONDING CONDUCTOR SIZING SCHEDULE

* BY EQUIPMENT MANUFACTURER, PER NEC 250.66

GROUNDING ELECTRODE CONDUCTOR #3/0

ANTENNA MAST TELECOM RACK ENCLOSURES #2

#3/0

MAIN BONDING JUMPER

INTERSYSTEM BONDING BUS BAR

#6

#3/0

#6

1. MAKE CONNECTION TO ALL AVAILABLE ELECTRODES. NOT ALL MAY BE PRESENT.

2. ALL GROUNDING AND BONDING TO BE IN ACCORDANCE WITH THE CURRENT VERSION

OF THE NEC THAT HAS BEEN ACCEPTED FOR USE IN EACH JURISDICTION AND AS

AMENDED BY LOCAL AUTHORITY HAVING JURISDICTION.

3. GROUND RODS TO BE INSTALLED OUTSIDE OF BUILDING ROOF'S DRIP LINE.

DETAIL NOTES

ITEM SIZE

UFER

GROUND

METAL

WATER

PIPES

OTHER

CONNECTIONS

AS NOTED

ON THE

PLANS

STRUCTURAL

STEEL

SPECIAL

SYSTEMS

GROUNDING

BUS

BARS

TELECOM

RACK

SPECIAL

SYSTEMS

CABLE

TRAY

SIZE PER TABLE

BELOW, TYPICAL

BOND AT

LOCATIONS

REQUIRED TO

MAINTAIN

CONTINUITY

GAS

PIPES

GROUND RODS

MINIMUM 6'-0"

OR 20'-0"

SPACING

WHERE

GROUND RING

PROVIDED

GROUND RING

CONDUCTOR WHERE

PROVIDED

NEUTRAL BUSGROUND BUS

MAIN BONDING

JUMPER

POWER

CABLE

TRAY

ANTENNA

MAST

AS SHORT AND

STRAIGHT AS

POSSIBLE

SERVICE EQUIPMENT

GROUNDING ELECTRODE

CONDUCTOR

SERVICE

GROUND BUS

BAR -

E-502

E-502

1. ALL HARDWARE SHALL BE HOT DIP GALVANIZED.

DETAIL NOTES

CONDUIT CLAMP AND

HANGER - 3' MAX.

FROM BOX TO HANGER

& 8' MAX. SPACING

BETWEEN HANGERS

(TYP.)

STEEL OUTLET BOX

- SIZED PER N.E.C.

AND SUPPORTED

RIGIDLY FROM

STRUCTURE (TYP.)

CONDUIT (TYP.)

6' MAX. LENGTH

FLEX CONDUIT

W/ (3)#12

CONDUCTORS

INTO FIXTURE

(TYP.)

TYPICAL

LAY-IN

RECESSED

LIGHT

FIXTURE

(TYP.)

SECURE

FIXTURES

TO GRID

WITH CLIPS

PER N.E.C.

(TYP.)

T-BAR LAY-IN

CEILING

SUSPENSION

SYSTEM (TYP.)

PROVIDE

SUPPORT

WIRES TO

STRUCTURE

FOR FIXTURE

SUPPORT, TWO

PER FIXTURE

(TYP.) SEE

SPEC SECTION

265100.

TYPICAL RECESSED LIGHTING INSTALLATION3

1. DO NOT SUPPORT CONDUIT OR BOX FROM CEILING GRID HANGERS.

DETAIL NOTES

JOIST (TYP.)

SCALE: NTS

POWER

POWER

COMMON

CONTROL

CONTROL

COMMON

POWER

CONTROL

COMMON

NEUTRAL

HOT

PO

W

ER

PACK

C O

M M

O N

C O

N

TR

O L

POWER

MOUNT IN

ACCESSIBLE SPACE

LUMINARIES

AS

REQUIRED/

INDICATED

CLNG./WALL

SENSOR

OCCUPANCY/VACANCY SENSOR SCHEMATIC4

1. COORDINATE INSTALLATION WITH SPECIFIC MANUFACTURER'S INSTALLATION REQUIREMENTS AND WIRING DIAGRAMS. PROVIDE ALL BOXES, RACEWAY, COMPONENTS AND CONDUCTORS AS REQUIRED FOR COMPLETE OPERATIONAL SYSTEM.

2. ALL CONDUCTORS SHALL BE 600V RATED UNLESS OTHERWISE NOTED.

3. POWER PACKS SHALL BE LOCATED WITHIN ACCESSIBLE CEILING SPACE WITHIN 5' OF DOOR FOR ROOM SERVED WHERE POSSIBLE.

4. OCCUPANCY SENSOR SHALL BE PROVIDED WITH AUXILIARY RELAY FOR CONNECTION TO HVAC CONTROL SYSTEM AND SHALL BE UL916

LISTED FOR ENERGY MANAGEMENT.

5. ALL LOW VOLTAGE WIRING CONCEALED WITHIN WALLS OR ABOVE HARD-LID CEILING SHALL BE ROUTED WITHIN RACEWAY.

6. RECEPTACLE SHALL HAVE "CONTROLLED" ENGRAVED ON FACE.

DETAIL NOTES

TO

HVAC

NEUTRAL

HOT

PO

W

ER

PACK

C O

M M

O N

C O

N

TR

O L

POWER

N

EU

TR

A L

C O

N

TR

O

LL

ED

H

O

TO

V

ER

R

ID

E

OVERRIDE

COMMON

MOMENTARY

CONTACT

SWITCH

O V

ER

R

ID

E

MOUNT IN

ACCESSIBLE SPACE

LIGHTING

CIRCUIT

RECEPTACLE

CIRCUIT

CLNG./WALL

SENSOR

TO

HVAC

(NOTE 4)

(NOTE 4)

SCALE: NTS

WHERE

APPLICABLE

TYPICAL FIRE ALARM RISER DIAGRAM6

FACP

FAN SHUTDOWN

CONTROL

HOOD FIRE

SUPPRESSION SYSTEM

ROLL-UP DOOR

FUSIBLE LINK

PRIMARY

ELEVATOR RECALL

ALTERNATE

ELEVATOR RECALL

CAR VISUAL RECALL

SIGNAL (HAT)

FA

A REMOTE

ANNUNICATOR

J

JUNCTION BOX FOR 120V

POWER TO SPRINKLER BELL.

SEE PLANS FOR LOCATION IF

REQUIRED.

NOTIFICATION

CIRCUIT

BELL-CKT

NOTIFICATION

CIRCUIT

(TYP.) (TYP.) (TYP.) (TYP.)

AUXILIARY POWER

SUPPLY (NAC)

120 VAC

S S

(TYP.) (TYP.) (TYP.)

FAN SHUT DOWN

CONTROL

SMOKE, HEAT,

DUCT DETS

PULL STATIONS

(TYP.)

DH

DH

120 VAC

MAGNETIC DOOR

HOLDERS

(TYP.)

#12 (TYP.)

F/S

F/S

120 VAC

FIRE/SMOKE

DAMPERS (TYP)

#12 (TYP.)

BATTERIES

120 VAC

TO PHONE

DEMARC BOARD

3/4" C 4-PAIR

TELEPHONE CABLE.

DACT (AUTO DIALER)

TYPICAL COMMUNICATIONS RISER DIAGRAM5

TELEPHONE/CATV

TERMINAL BOARD

SIZE AS INDICATED ON

PLANS.

NETWORK/VOICE

(TYP.)

VOICE

(TYP.)

TV OUTLET

2"C w/(2)-RG11/U TO CABLE TV SERVICE

4" CONDUIT TO TELEPHONE COMPANY MAIN SERVICE

6 AWG 3/4" C.

COPPER TO

SERVICE GROUND

OR INTERSYSTEM

BONDING BUS

(TYP.) (TYP.) (TYP.) (TYP.)

NUMBER OF CONDUCTORS

AS REQUIRED FOR

APPLICABLE ZONES

LF LF

LF LF

3/4"C w/

(1)-CAT6

3/4"C w/

(1)-CAT6

3"C 3/4"C w/(1)-RG6/U

AND (1)-CAT6

ALARM

CIRCUIT

TAMPER, FLOW SENSORS

SCALE: NTSSCALE: NTS

120V DEDICATED

CIRCUIT

1. FIRE ALARM SYSTEM AS SHOWN IS SCHEMATIC ONLY AND DOES NOT INDICATE ALL DEVICES, EQUIPMENT, WIRING. PROVIDE COMPLETE SYSTEM WITH ALL REQUIRED DEVICES AND EQUIPMENT AND SUBMIT ENGINEERED DRAWINGS TO AHJ FOR REVIEW AND APPROVAL.

DETAIL NOTES

1. COMMUNICATIONS DIAGRAM AS SHOWN IS SCHEMATIC AND DOES NOT INDICATE ALL DEVICES, EQUIPMENT, WIRING. PROVIDE

COMPLETE SYSTEM WITH ALL REQUIRED DEVICES AND EQUIPMENT.

DETAIL NOTES

ACCESSIBLE CEILING

TV

F

TF

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL JPS/FEB

100% CD

Revisions: Date:

E-501

ELECTRICAL DETAILS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL JPS/FEB

100% CD

Revisions: Date:

E-501

ELECTRICAL DETAILS

GENERAL NOTES:

1. MAINTAIN A MINIMUM CLEARANCE OF 305mm (12") ON ALL SIDES OF ROOF

PENETRATION FROM WALLS, CURBS, AND OTHER PROJECTIONS TO FACILITATE

PROPER FLASHING.

2. FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT OR OVERLAPPED.

3. VERIFY ROOF & STRUCTURAL SYSTEM WITH ARCHITECT.

4. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR TO ENSURE

PROPER METHODS & MATERIALS ARE USED TO MAINTAIN ROOF WARRANTY.

PREFABRICATED RUBBER BOOT

CAP WITH GRADUATED STEPS

& WEATHER-PROOF PRESSURE

SEAL TO COLLAR

SEALANT AT PENETRATION

TO MEMBRANE JUNCTURE BY

ROOFING CONTRACTOR MULTIPLE MEMBRANE STRIPPING

PLIES FEATHERED AT FIELD OF ROOF

BY ROOFING CONTRACTOR. PRIME

FLANGE BEFORE STRIPPING.

PREFABRICATED FORMED 1.52mm

(0.06") THICK ALUMINUM

FLASHING ROUND COLLAR WITH

MIN. 76mm (3") WIDE FLANGE.

ATTACH TO ROOF PER

MANUFACTURER'S INSTRUCTIONS

CONDUIT CLAMP. SIZE AS

REQUIRED

BATT INSULATION

ROOF MEMBRANE

WATER CUT-OFF MASTIC

COMPATIBLE WITH ROOF

MEMBRANE

STAINLESS CLAMP, TYP.

9.52mm (3/8")

MIN

GALVANIZED

THREADED ROD,

TYP.

ROOF

STEEL

EXPANSION

ANCHOR

INTEGRAL GALVANIZED

LIPPED STEEL

MOUNTING CHANNEL

CONDUIT,

TYP.

CONDUIT CLAMP.

SIZE AS

REQUIRED

LOCKING

SQUARE

WASHER &

LOCKNUT

SEALANT, TYP

CONDUIT ROOF PENETRATION DETAIL2

- SCALE: NTS

SCALE: NTS SCALE: NTS

1. REFERENCE SPECIFICATIONS 087100 AND 281300 FOR ADDITIONAL INFORMATION/REQUIREMENTS.

2. COORDINATE ALL VA NETWORK CONNECTIONS WITH VA COR.

3. PROVIDE REQUEST-TO-EXIT ON ALL ACCESS CONTROLLED DOORS; REFERENCE SPECIFICATION FOR EXACT

REQUIREMENTS.

DETAIL NOTES

SCALE: NTS

STEEL BEAM

CADWELD CONNECTION TYPE

QW (OR TYPE VN TO WEB OF

LARGE BEAM)

STEEL COLUMN

CADWELD CONNECTION TYPE VV

TO GROUND

EXOTHERMIC WELD

CONNECTION

NO. GBIT14412M-22T OR APPROVED EQUAL, 1/4" x 4" x

12" SOLID COPPER GROUND BAR WITH INSULATORS

AND BRACKETS, AND WITH TWO 25'-0" NO. 2T, #2 AWG

TIN COATED COPPER GROUND CONDUCTORS

#2AWG SOLID

TINNED CU

25FT LO

NG

SINGLE SWITCH

NEUTRAL

LINE

GREEN AND YELLOW

GREEN

BLACK

GROUND

RED

120V/230V/277V GROUND OR

347V (PW-100-347) (SEE

INSTALLATION INSTRUCTIONS)

DETAIL NOTES

1. ALL SENSORS TO BE DUAL TECHNOLOGY TYPE. SENSOR MUST INCLUDE

VISIBLE STATUS SIGNAL. REFER TO ALL APPLICABLE ENERGY CODES FOR

PRODUCT REQUIREMENTS. SENSOR MUST HAVE BUILT-IN SENSITIVITY

CALIBRATION AND ADJUSTMENT.

SCALE: NTS

SCALE: NTS

TYPICAL MV AND BUILDING TELECOMMUNICATIONS TRENCHING SECTION5

3"

3"

4"

3"3"3" 3"

3" 3"

12"

BACKFILL TO MATCH

EXISTING GRADE

ASPHALT OR CONCRETE

PAVING

PAVING BASE

SELECTED BACKFILL FREE OF

LARGE DEBRIS AND COMPACTED

PER VA SPECIFICATIONS

CONCRETE SLURRY MIX

MEETING VA STANDARDS

CONCRETE

ENCASEMENT IF

REQUIRED AS

SHOWN ON

PLANS

CONTINUOUS

WARNING TAPE.

TRACER WIRE

SHALL BE

ACCESSIBLE IN

ALL HAND

HOLES OR MAN

HOLE

X" MIN.

24"

MIN.

3"

PROVIDE AND SIZE CONDUITS

PER PLANS

- SCALE: NTS

SPS TRAILER EQUIPMENT DISCONNECT DETAIL6

WALL OCCUPANCY/VACANCY SENSOR4

TYPICAL GROUND BUS BAR FOR

INTERSYSTEM AND SERVICE GROUNDING3

BUILDING STEEL GROUND2

TYPICAL SECURITY ACCESS DOOR CONTROL (MAGNETIC LOCK TYPE)1

SCALE: NTS

EXISTING CT TRAILER DISCONNECT7

RELOCATE DISCONNECT AND REROUTE

CONDUITS AND CONNECTIONS AS REQUIRED

BUILDING #33

EXTERIOR WALL

MANUFACTURER

PROVIDED CORD,

TYP.

PLUG,

TYP.

DISCONNECT

TYP.

MEYERS HUB

TYP.

STAINLESS STEEL

UNISTRUT WITH

STAINLESS STEEL

FASTENING

HARDWARE, TYP.

RIGID METAL

CONDUIT,

TYP.

ID PLACARD

DETAIL NOTES

1. COORDINATE WITH CIVIL ENGINEER FOR ALL TRENCHING MATTERS

INCLUDING, BUT NOT LIMITED TO, PAVEMENT RESTORATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL/WNM JPS/FEB

100% CD

Revisions: Date:

E-502

ELECTRICAL DETAILS

JUNCTION BOX, 8" x 8" x 4"

MINIMUM

TO SECURE LOCAL ACCESS

CONTROL PANEL, 1-1/2" CONDUIT

ELECTRIC STRIKE PER SYSTEM

REQUIREMENTS, PROVIDE

BACKBOX AS REQUIRED BY

MANUFACTURER

DUAL AUTHENTICATION CARD

READER AND KEYPAD, 42" AFF,

HID pivCLASS #RK40 OR

EQUIVALENT, PROVIDE 4"

SQUARE BACKBOX WITH MUD

RING. INSTALL PER

MANUFACTURER'S

INSTRUCTIONS.

SUSPENDED CEILING

FLOOR

DOOR POSITION SWITCH AND

MAGNET

CONTINUE TO REQUEST-TO-EXIT

FIELD MOUNTED DEVICE, 3/4"

CONDUIT

3/4" CONDUIT

LOAD

SCALE : NTS

SCOPE PROCESSING AREA ONE-LINE DIAGRAM - EXISTING1

ROOF

INTERSTITIAL

4TH FLOOR

INTERSTITIAL

3RD FLOOR

INTERSTITIAL

2ND FLOOR

INTERSTITIAL

1ST FLOOR

INTERSTITIAL

BASEMENT

1QC4 (E)

XXX/XXXV

3P 4W

TO QDPB #2

RM 1D-139

3QC2 (E)

XXX/XXXV

3P 4W

RM 3D-136 RM 3D-127

QMCCB3 (E)

XXX/XXXV

3P 4W

RM 3F-105

TRANSFORMER

"T2" (E)

BDE2 (E)

208/120V 3P 4W

TRANSFORMER

"T2" (E)

TO PANEL "EDPB",

CIRCUIT #4

60AS60AF

175AS175AF

450AS450AF

50AS50AF

J

RIDER D-N 1200A 3PH, 4W

BUS DUCT 480V

J

J

J

TRANSFORMER "T9"

3PH (E)

(3) 4"C - (12)

400KCM, #3/0G

QMCCB2 (E)

480/277V 3P 4W

NMCCB3 (E)

480/277V 3P 4W

QMCCB2.1 (E)

480/277V 3P 4W

TRANSFORMER

"T3" (E)

PBN4 (E)

480/277V 3P 4W

4DQ2 (E)

208/120V 3P 4W

3DQ2 (E)

208/120V 3P 4W

2DQ2 (E)

208/120V 3P 4W

1DQ2 (E)

208/120V 3P 4W

RM BD-110

BF-104

RM JD-123

1F-105

RM 2D-151

2F-104

3F-104

4F-104

RM 3D-120

RM 4D-114

G

TO QMCC-A3

TO QMCC-B2

SUPPLY FAN

EXISTING PANEL TO BE DEMOLISHED.

EXISTING CONDUCTORS TO BE DEMOLISHED BACK TO

SOURCE. EXISTING RACEWAY TO REMAIN TO BE REUSED.

REFERENCE DRAWING E-602 FOR ADDITIONAL INFORMATION.

EXISTING MOTOR CONTROL CENTER PROVIDES POWER TO

BONE MARROW UNIT. COORDINATE ALL WORK WITH VA

PRIOR TO COMMENCING WORK ASSOCIATED WITH MOTOR

CONTROL CENTER. CONTRACTOR SHALL PROVIDE 30-DAY

NOTIFICATION OF OUTAGE WITH PROPOSED OUTAGE PLANT

TO ENGINEER AND VA COR. OUTAGE SHALL BE LIMITED TO

1-HOUR. REFERENCE SHEET E-602 FOR ADDITIONAL

INFORMATION.

COORDINATE DEMOLITION WORK WITH BONE MARROW UNIT

POWER REQUIREMENTS. REFERENCE GENERAL NOTE '3' AND

KEY NOTES '2' AND '3' FOR ADDITIONAL INFORMATION.

EXISTING PANEL TO BE MODIFIED. REFERENCE PANEL

SCHEDULE ON SHEET E-607 FOR ADDITIONAL INFORMATION.

1. WHEN REPLACING A BRANCH PANELBOARD, RE-CIRCUIT

EXISTING LOADS TO SAME POLE NUMBERS AS PREVIOUS.

IDENTIFY ALL EXISTING LOADS TO REMAIN AND PROVIDE

COMPLETE ACCURATE PANEL INDEX. EXAMPLE: IF EXISTING

DOCK RECEPTACLES ARE CIRCUITED TO BDN2.1-28,

RE-CIRCUIT TO BDN2.1-28 IN NEW PANEL BDN2.1, UNLESS

OTHERWISE INDICTED.

2. EXISTING LOAD INFORMATION IS BASED ON RECORD

DRAWINGS AND FIELD OBSERVATIONS. CONTRACTOR SHALL

FIELD VERIFY ALL EXISTING LOADS TO REMAIN.

3. CONTRACTOR SHALL PROVIDE TEMPORARY POWER AS

REQUIRED TO MAINTAIN EQUIPMENT/FACILITY OPERATION;

DOWN TIME SHALL BE MINIMIZED AS MUCH AS POSSIBLE.

PRIOR TO ANY OUTAGES, CONTRACTOR SHALL PROVIDE

30-DAY NOTIFICATION OF OUTAGE WITH PROPOSED OUTAGE

PLAN TO ENGINEER AND VA COR.

4. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS.

ANY DISCREPANCIES FOUND SHALL BE REPORTED TO THE

ENGINEER.

GENERAL NOTES

KEY NOTES (THIS SHEET ONLY)

BDE4 (E)

480/277V 3P 4W

BDN4 (E)

208/120V 3P 4W

BDN2.1 (E)

208/120V 3P 4W

BDN2.2 (E)

208/120V 3P 4W

BDQ4 (E)

480/277V 3P 4W

BDQ2 (E)

208/120V 3P 4W

BDN3 (E)

208/120V 3P 4W

TO SUBSTATION "B",

CIRCUIT BREAKER #1

RM BD-100C RM BD-100C RM BD-111C

TO QDPB #3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL/WNM JPS/FEB

100% CD

Revisions: Date:

E-601

SCOPE PROCESSING AREA

ONE-LINE DIAGRAM - EXISTING

PREP & STERILE

WORKROOM

CONTAINMENT

ROOM

TYP.

REFERENCE SHEET E-603 FOR

ADDITIONAL INFORMATION

SCALE : NTS

SCOPE PROCESSING AREA ONE-LINE DIAGRAM - REVISED1

REFERENCE LOAD SCHEDULES FOR FOR ADDITIONAL

INFORMATION.

PRIOR TO DISCONNECTING POWER TO "QMCCB2.1" (BONE

MARROW UNIT), PROVIDE CONDUIT AND WIRE EXTENDING

FROM PANELBOARD "BDQ4" TO NEW JUNCTION BOX (SIZE

PER NEC); WIRE PROVIDED SHALL BE ENOUGH TO EXTEND

FROM "BDQ4" TO "QMCCB2.1" - COIL EXCESS WIRE AS

REQUIRED. ONCE POWER HAS BEEN DISCONNECTED FROM

"QMCCB2.1", DEMOLISH EXISTING FEEDER CONDUCTORS

EXTENDING FROM "BDQ4" TO "QMCCB2.1", EXTEND EXISTING

CONDUIT FEEDING "QMCCB2.1" TO NEW JUNCTION BOX, AND

INSTALL AND TERMINATE NEW WIRE THROUGH EXISTING

CONDUIT TO "QMCCB2.1" AS REQUIRED.

EXISTING MOTOR CONTROL CENTER PROVIDES POWER TO

BONE MARROW UNIT. COORDINATE ALL WORK WITH VA

PRIOR TO COMMENCING WORK ASSOCIATED WITH MOTOR

CONTROL CENTER.

MODIFIED PANEL. REFERENCE PANEL SCHEDULE ON SHEET

E-607 FOR ADDITIONAL INFORMATION.

1. WHEN REPLACING A BRANCH PANELBOARD, RE-CIRCUIT

EXISTING LOADS TO SAME POLE NUMBERS AS PREVIOUS.

IDENTIFY ALL EXISTING LOADS TO REMAIN AND PROVIDE

COMPLETE ACCURATE PANEL INDEX. EXAMPLE: IF EXISTING

DOCK RECEPTACLES ARE CIRCUITED TO BDN2.1-28,

RE-CIRCUIT TO BDN2.1-28 IN NEW PANEL BDN2.1, UNLESS

OTHERWISE INDICTED.

2. EXISTING LOAD INFORMATION IS BASED ON RECORD

DRAWINGS AND FIELD OBSERVATIONS. CONTRACTOR SHALL

VERIFY ALL EXISTING LOADS TO REMAIN.

GENERAL NOTES

KEY NOTES (THIS SHEET ONLY)

ROOF

INTERSTITIAL

4TH FLOOR

INTERSTITIAL

3RD FLOOR

INTERSTITIAL

2ND FLOOR

INTERSTITIAL

1ST FLOOR

INTERSTITIAL

BASEMENT

TO QDPB #2

RM 1D-139

RM 3D-136 RM 3D-127

RM 3F-105

60AS60AF

175AS175AF

450AS450AF

50AS50AF

J

RIDER D-N 1200A 3PH, 4W

BUS DUCT 480V

J

J

J

(3) 4"C - (12)

400KCM, #3/0G

RM BD-110

BF-104

RM JD-123

1F-105

RM 2D-151

2F-104

3F-104

4F-104

RM 3D-120

RM 4D-114

TO QMCC-A3

TO QMCC-B2

SUPPLY FAN

G

(1) 3" C. W/(4) 4/0 AWG &

(1) 6 AWG GND

1 1 1 1 1 1

1 1

TO PANEL "EDPB",

CIRCUIT #4

TO SUBSTATION "B",

CIRCUIT BREAKER #1

B126 BD121

RM BD-111C

TO QDPB

1QC4 (E)

XXX/XXXV

3P 4W

3QC2 (E)

XXX/XXXV

3P 4W

QMCCB3 (E)

XXX/XXXV

3P 4W

TRANSFORMER

"T2" (E)

BDE2 (E)

208/120V 3P 4W

TRANSFORMER

"T2" (E)

TRANSFORMER "T9"

3PH (E)

QMCCB2

480/277V 3P 4W

NMCCB3

480/277V 3P 4W

QMCCB2.1 (E)

480/277V 3P 4W

TRANSFORMER "T3"

112.5kVA, 480-120/208V

PBN4

480/277V 3P 4W

4DQ2 (E)

208/120V 3P 4W

3DQ2 (E)

208/120V 3P 4W

2DQ2 (E)

208/120V 3P 4W

1DQ2 (E)

208/120V 3P 4W

BDE4

480/277V 3P 4W

BDN4(E)

208/120V 3P 4W

BDN2.1

208/120V 3P 4W

BDN2.2

208/120V 3P 4W

BDQ4

480/277V 3P 4W

BDQ2

208/120V 3P 4W

BDN3

208/120V 3P 4W

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING SERVICES

IN BUILDING 100

VA PUGET SOUND HEALTH CARE SYSTEM - Seattle, WA

663-20-102

06/25/2021 LRL/WNM JPS/FEB

100% CD

Revisions: Date:

E-602

SCOPE PROCESSING AREA

ONE-LINE DIAGRAM - REVISED

PREP & PACK SOILED ANTE

J 2

(1) 2" C. (4) 3/0 AWG & (1)

6 AWG GND

(1) 2" C. (3) 3/0 AWG & (1) 6

AWG GND

(1) 4" C. W/(4) 600 KCMIL &

(1) 3 AWG GND

REFERENCE SHEET E-603 FOR

ADDITIONAL INFORMATION

(1) 2-1/2" C. W/(4) 250KCMIL

& (1) 4 AWG GND

EXISTING CONDUIT.

REFERENCE KEY NOTE 2.

(1) 1" C. W/(3) 8 AWG

& (1) 8 AWG GND

(2) 3" C. EA. W/(4) 350KCMIL

& (1) 1 AWG GND

REFERENCE LOAD SCHEDULES FOR FOR ADDITIONAL INFORMATION.

TRAILER MANUFACTURER TO PROVIDE CORD. CONTRACTOR TO INSTALL AND

PROVIDE PVC RACEWAY TO PROVIDE PROTECTION FOR CORD; CONTRACTOR

SHALL COORDINATE EXACT ROUTING AND SIZE OF PVC RACEWAY WITH TAILER

MANUFACTURER.

SCALE : NTS

MOBILE STERILIZATION TRAILER PARTIAL ONE-LINE DIAGRAM1

K K

SUBSTATION

"A"

K 5252K 5252

2500 kVA 13.8kV:

480Y/277V

LV

AL1

LV

AL2

LV

AL3

LV

AL4

LV

AL5

LV

AL6

LV

AL7

LV

AL8

LV

AR8

LV

AR7

LV

AR6

LV

AR5

LV

AR4

LV

AR3

LV

AR2

LV

AR1

2500 kVA 13.8kV:

480Y/277V

MAL1 MAR1

MAL2 MAR2

AUTOMATIC

THROWOVER

SYSTEM

TA

S1AR N1ARS1AL N1AL

50P

SEL 351-7

51P 51G 50P

SEL 351-7

51P 51G

CONTINUE TO

EXISTING FEEDERS

CONTINUE TO

EXISTING FEEDERS

60/3

SPD

250/3

LS

I

800/3

LSI

SWITCHBOARD "SWBD-AN-1",

800A, 480/277V, 3PH, 4W, 65KAIC

250A/3P

DPM

PWR

CONNECTION

#1

250/3

LS

I 250A/3P

PWR

CONNECTION

#2

SPS MOBILE TRAILER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

625 1ST AVE, UNIT #301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES

RENOVATE & EXPAND SEATTLE

STERILE PROCESSING…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .