This is a product specification document for cubic yard boxes with lids to be used by the Bureau of Engraving and Printing for shipping filter press cake sludge from the wastewater pretreatment plant process.

The boxes must be multi-wall fiberboard construction with water-resistant adhesive, capable of holding 2,500 pounds of moist filter press cake sludge. Specifications include minimum double wall construction with a board combination of 90/40/90/40/90/40/90, burst strength of 100 pounds minimum, puncture resistance of 1,450 pounds minimum, and short column compression of 195 pounds minimum. Inside dimensions must be 45.25 inches long, 37.5 inches wide, and 40 inches high with 5-inch flaps on the top cover and half-slotted side corners. Boxes must fit on a standard 40-inch by 48-inch pallet with no overhang. The specification requires bottom closure to be scored and slotted or scored for erection, and boxes must be delivered in a knocked-down (flat) condition. Testing requirements mandate that when two 4-mil polyethylene liners are installed in an erected box filled with water, the box must withstand the load for three days with only slight bulging allowed.

Environmental and safety compliance certifications are required prior to delivery, including adherence to 40 CFR 720, 40 CFR 761, 40 CFR Part 268 Subpart B, SARA Title III, EPA procedures, and District of Columbia and California regulations. Shipping, marking, and labeling must conform to DOT, OSHA, HMIS, and freight classification regulations. A safety data sheet must be submitted two weeks before first delivery and upon any material changes. The boxes and lids will ultimately be used to provide secure closed storage for the sludge waste material, which will be transported to an appropriately licensed disposal facility, recycling facility, or alternate use facility.

View the file

Other files

File Type Posted
Attachment A - PWS Waste Water Pretreatment Plant Operation and Maintenance_6 Oct 2026.pdf PDF
2031ZA26R00023 0004.pdf PDF
2031ZA26R00023 0003.pdf PDF
Attachment A - PWS Waste Water Pretreatment Plant Operation and Maintenance_v5 - 21 Aug 2026.pdf PDF
WWPP - Request for Clarifications-Questions-Answers.xlsx XLSX spreadsheet
Attachment B - Pricing Sheet - 21 Aug 2026.xlsx XLSX spreadsheet
Attachment D - Past Performance Questionnaire.docx DOCX document
2031ZA26R00023 0002 - 07 Aug 2026.pdf PDF
2031ZA26R00023 0001 - 06 Aug 2026.pdf PDF
Attachment C - Site Visit Information - 6 Aug 2026.docx DOCX document
Attachment B - Pricing Sheet - 6 Aug 2026.xlsx XLSX spreadsheet
Att 19 - Sodium-Sulfated Castor Oil Specification.pdf PDF
Att 23 - Spare Parts and Supplies.pdf PDF
Att 2 - WSWPP Process Description.pdf PDF
Attachment 29 - Monthly Workforce Report.docx DOCX document
Att 12 - EHS Requirements for Purchased Materials.pdf PDF
Att 22 - Process and Treatment Chemicals.pdf PDF
Att 8 - EHS Contractor Requirements.pdf PDF
Att 25 - Laboratory Analysis.pdf PDF
Attachment C - Site Visit Information.pdf PDF
Att 4 - GTWPP Process Description.pdf PDF
Att 14 - Bentonite Specification.pdf PDF
Att 17 - Filter Aid Specification.pdf PDF
Att 1 - BEP 017-12.pdf PDF
Att 18 - Sodium Hydroxide Specification.pdf PDF
Att 3 - PWPP Process Description.pdf PDF
Att 24 - Nonreimburseable Tools - Janitorial - PPE Supplies.pdf PDF
Att 15 - Sulfuric Acid Specification.pdf PDF
Att 21 - Pallets Specification.pdf PDF
Att 11 - Wage Determination.pdf PDF
Att 10 - PWPP Equipment List.pdf PDF
Att 9 - WSWPP Equipment List.pdf PDF
2031ZA26R00023 WWPP Solicitation.pdf PDF
Attachment A - PWS Waste Water Pretreatment Plant Operation and Maintenance_v4.pdf PDF
Att 5 - WSRP Process Description.pdf PDF
Attachment 28 Staffing Plan.doc DOC document
Att 13 - Restricted Materials at DCF.pdf PDF
Att 26 - Equipment.pdf PDF
Attachment 27 - Corrosion Monitoring.pdf PDF
Att 16 - Sodium Bisulfite Specification.pdf PDF
Attachment B - Pricing Sheet.xlsx XLSX spreadsheet
Att 7 - BEP Furnished Equipment.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 20

Page 1 of 4 Pages

SPECIFICATION FOR CUBIC YARD BOXES WITH LIDS

(a) SCOPE AND CLASSIFICATION

This specification covers Cubic Yard Boxes of multi-wall construction and water resistant adhesive supplied with Lids. At the time of delivery these materials shall meet the following physical properties listed below.

(b) PRODUCT SPECIFICATIONS

The fiberboard boxes shall meet the following specifications and be used to ship the filter press cake sludge from the Bureau of Engraving and Printing.

(1) Each box shall be capable of holding 2,500 lbs of moist filter press cake sludge.

(2) The multiple wall construction cubic yard boxes shall be a minimum of double wall with multi-wall construction and have water-resistant adhesive along with the below listed properties:

PROPERTY REQUIREMENT

Burst Strength 100 pounds minimum

Board Combination 90/40/90/40/90/40/90

Puncture Resistant 1450 pounds minimum

Box Compression Factor 1.15

Short Column Compression 195 pounds minimum

Inside Dimensions

45.25-long, 37.5-inches wide and 40-inches high, 5-inch flaps on top cover and a cover top. The side corners shall be half-slotted.

The Pad

Closure in accordance with Rule 41, Section 7. The box is required to fit on a pallet 40-inches x 48-inches with no overhang.

Bottom Closure Scored and slotted or scored for erection.

Maximum Holding Capacity 2,500 Pounds.

Testing

With two 4-mils thick polyethylene liners installed in an erected box, the box shall be capable to be filled with water; slight bulging will be allowed.

The box must not fail after three days.

Page 2 of 4 Pages

(3) DOUBLE WALL/TRIPLE WALL CONSTRUCTION: Laminated with one layer of double wall and one layer of triple wall construction fiberboard. The outer double wall structure makes up the RSC Bottom and 5-inch top flap. The fluted structure is CA/CAA. Board combination shall be: 90/40/90/40/90/40/90

(4) Boxes to be delivered knocked down (flat).

(c) RELATIVE ENVIRONMENTAL CONDITIONS

A safety data sheet of the product shall be forwarded by the Supplier and received by the Bureau of Engraving and Printing two (2) weeks before the first delivery and upon any material changes. The following specifications, standards and handbooks form a part of this document to the extent specified herein.

(1) Certification of Compliance with Environmental and Safety

Regulations

Certificates are required to show that the material complies with the following regulations:

a. 40 CFR 720 – Pre-manufacture Notification: Pre-manufacture Notification Requirements and Review Procedures.

b. 40 CFR 761 - Polychlorinated Biphenyl (PCB's)

Manufacturing, Processing, Distribution in Commerce, and use Prohibitions.

c. 40 CFR Part 268, Subpart B - Schedule for Land Disposal

Prohibitions and Establishments of Treatment Standards.

d. Superfund Amendment and Reauthorization Act (SARA), Title III.

e. Test Methods for Evaluation of Solid Waste; EPA Procedure

1030 and Number 7420 SW - 846, Third Edition, November, 2004.

f. District of Columbia Air Pollution Control Act of 1984.

(Copies may be obtained from the District of Columbia Office of Documents, Room 523, the District Building, Washington, D.C. 20004.)

Page 3 of 4 Pages

g. District of Columbia Rules and Regulations - Title 8 - Health regulations, Chapter 2, Part 7. (Published by the Office of Air and Water Quality, Environmental Control Division, Department of Consumer and Regulatory Affairs, Government of the District, 510 Overlook Avenue, S. W., Washington, D. C. 20032.)

h. California's "Safe Drinking Water and Toxic Enforcement

Act" of 1986. Request for copies should be addressed to the State of California Health and Welfare Agency, 1600 Ninth Street, Room 450, Sacramento, California, 95814.

(2) Compliance with Shipping, Marking and Labeling Regulations

The shipping, marking and labeling shall conform to the applicable requirements of DOT, OSHA, HMIS, Uniform Freight Classification Rules, Motor Freight Classification Rules listed below:

a. 29 CFR 1910, Part 1200 - Hazard Communication Standard

(Occupational Safety and Health Administration). See also Federal Register Volume 77, Number 58, March 26, 2012.

b. Hazardous Material information System (HMIS) for Labeling.

(Request for copies should be addressed to the National Paint and Coating Association 1500 Rhode Island Avenue, Washington, D.C. 20005).

c. National Motor Freight Classification Rules and Container

Specification. (Request for copies should be addressed to the American trucking Association, Inc., 2000 Mill Road, Alexandria, Virginia 22314.

d. Uniform Freight Classification Rules. (Request for copies should be addressed to the Uniform Classification Committee, 222 South Riverside Plaza, Chicago, IL 60600.)

(d) ORDER OF PREFERENCE

In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence.

Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.

(e) INTENDED USE

Page 4 of 4 Pages

The box and lid will be used to provide secure closed storage for an inert sludge waste material produced from the wastewater pretreatment plant process. This material will be transported to and disposed of in an appropriately licensed disposal facility, a recycling facility, or an alternate use facility.

END OF SPECIFICATION FOR CUBIC YARD BOXES WITH LIDS