ATT 1- Grand Junction EHRM - Drawings 07-03-25.pdf

PDF 11 MB Posted

Attached to
Y1DA--575-21-700 | Construction| EHRM Infrastructure Upgrades | Grand Junction, CO
Solicitation number
36C77625B0039
Issued by

About this file

This is a comprehensive set of telecommunications infrastructure upgrade drawings for the EHRM Infrastructure Upgrades project at the Grand Junction VA Medical Center. The project involves extensive modifications to telecommunications rooms (TRs) across multiple buildings, including buildings 1, 5, 6, 7, 8, 9, 12, 20, 35, 36, 37, 39/44, and 45. Key technical requirements include upgrading existing infrastructure with new Category 6A cabling, installing new data outlets, replacing patch panels, implementing new fiber optic backbone cabling between buildings, and establishing diversified network paths. The drawings detail precise specifications for telecommunications room configurations, including rack layouts, cable management, grounding systems, and pathways, with specific attention to fiber optic route planning, conduit specifications, and integration of new electrical and network infrastructure components across the campus.

View the file

Other files

File Type Posted
S05 - 575-21-700 Tech Questions responses updated - GJ CO - 8-28-25.docx DOCX document
575-700.VA Archtitectural Grand Junction EHRM Addendum 2 - Changed Sheets Only.pdf PDF
For Information Only - B44_2013_TERRACON_41013_Parking_Garage.pdf PDF
575-700.VA Civil Grand Junction EHRM Addendum 2 - Fiber Optic Manhole Detail.pdf PDF
575-700.VA Telecom Grand Junction EHRM Addendum 2 - Changed Sheets Only.pdf PDF
For Information Only - B9_2019_Geotech_Report_HB_Boiler_Plant.pdf PDF
575-700.VA Mechanical Grand Junction EHRM Addendum 2 - Changed Sheets Only.pdf PDF
S06- Amendment 0009.pdf PDF
S06 - Amendment 0008.pdf PDF
S06- Amendment 0007.pdf PDF
32 05 23 Cement and Concrete for Exterior Improvements.pdf PDF
32 12 16 Asphalt Paving.pdf PDF
CIP concrete short form.pdf PDF
S06- Amendment 0006- Bid due date extended 08-28-25.pdf PDF
S06- Amendment 0005- Bid due date extended.pdf PDF
S06- Amendment 0005- Bid due date extended.pdf PDF
B12 Roof 20250730.pdf PDF
S06- Amendment 0004- Bid opening info and all tech questions responses.pdf PDF
4 Utility Plan.pdf PDF
B7 Roof 20250730.pdf PDF
S05 - 575-21-700 All Tech Questions Responses - CO.docx DOCX document
S06- Amendment 0003 - DB Wages updated - Bid extension - RFI answers.pdf PDF
S05 - 575-21-700 Tech Questions Responses- GJ CO 07-28-25.docx DOCX document
P07- Updated Wages Determination - Grand Junction CO 07-25-2025.pdf PDF
S04- Signed site visit sign in sheet - 57521700 CO.pdf PDF
S06- Amendment 0002- Signed site visit sheet.pdf PDF
ATT 12- Drawings - EHRM - Grand Junction - CO.pdf PDF
ATT 13- Specifications-Combined- EHRM - Grand Junction CO.pdf PDF
ATT 4- Grand Junction CO - SPECS 07-03-25- Addendum.pdf PDF
ATT 11 - Site Visit Instructions.pdf PDF
ATT 1- Grand Junction EHRM - Drawings 07-03-25 - Addendum.pdf PDF
S06 - Amendment 0001.pdf PDF
ATT 7 - Spec 01 31 00.01 Project Management and Coordination.pdf PDF
ATT 3- Estimated Construction Schedule- EHRM- Grand Junction CO.pdf PDF
ATT 10 - GEO Reports B20.pdf PDF
ATT 6 - Wages Determination - Grand Junction CO.pdf PDF
ATT 5- 100 CD Basis of Design -Combined- Grand Junction CO.pdf PDF
ATT 8 - Limitations on Subcontracting.docx DOCX document
36C77625B0039.pdf PDF
ATT 11- Site Visit Instructions.pdf PDF
ATT 4- Grand Junction CO - SPECS 07-03-25.pdf PDF
ATT 2- Parking Guidelines Grand Junction VAMC.pdf PDF
ATT 9- Hazardous Materials Report.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A. FOR ALL CONDUIT AND OTHER ITEMS PENETRATING A FIRE RATED WALL, PROVIDE UL LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM THAT IS SPECIFIC TO THE WALL CONSTRUCTION ASSEMBLY AND COMPLIANT WITH ASTM E814. INSTALL SYSTEM IN STRICT COMPLIANCE WITH THE FIRE STOPPING MANUFACTURER’S U.L.

APPROVED DETAIL. WHERE EXISTING WALLS ARE BEING UPGRADED TO FIRE RATED WALLS OR THE FIRE RATING IS BEING MODIFIED, PROVIDE U.L. LISTED THROUGH PENETRATION FIRE STOPPING SYSTEM FOR ALL NEW AND EXISTING PENETRATIONS. REFER TO THE ARCHITECTURAL LIFE SAFETY PLANS FOR LOCATIONS OF FIRE RATED WALLS.

B. NEW ROOF MOUNTED EQUIPMENT SHALL BE BONDED TO EXISTING BUILDING LIGHTNING PROTECTION SYSTEM IF ONE EXISTS. PROVIDE AIR TERMINALS ON TOP OF EQUIPMENT AND BOND TO EXISTING SYSTEM PER NFPA 780 AND UL 96A REQUIREMENTS. PROVIDE UL INSPECTION AND/OR LPI SYSTEM INSPECTION AS REQUIRED TO OBTAIN UL MASTER

LABEL RECERTIFICATION, UL MASTER LABEL AND/OR LPI SYSTEM CERTIFICATE.

C. ANY ITEMS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR, AT NO ADDITIONAL COST TO

THE OWNER.

D. NEW WIRING DEVICES AND ASSOCIATED COVERPLATES SHALL MATCH EXISTING FINISH OF SIMILAR INSTALLED

DEVICES.

E. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO INDEPENDENTLY SUPPORT ALL EXISTING TO REMAIN CABLING.

F. IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE ALL VOICE AND DATA CABLING AND ASSOCIATED

OUTLETS ARE UPGRADED AS A PART OF THIS PROJECT. DRAWINGS REFLECT GENERAL DEVICE OUTLET LOCATIONS BASED ON FIELD OBSERVATIONS AND CABLE QUANTITIES BASED ON SURVEYS PROVIDED BY THE VA OIT TEAM. FIELD INVESTIGATIONS DURING CONSTRUCTION WILL BE REQUIRED TO CONFIRM EXACT

QUANTITIES AND DEVICE LOCATIONS.

G. CABLE QUANTITIES INDICATED FOR EACH BUILDING ARE APPROXIMATE BASED ON FIELD OBSERVATIONS AND READINESS INFRASTRUCTURE SELF-ASSESSMENTS PROVIDED BY THE VA. SOME LOCATIONS WERE UNABLE TO BE SURVEYED FOR EXISTING COMMUNICATIONS OUTLETS AND CABLING DUE TO PATIENT CARE. CONTRACTOR SHALL ACCOUNT FOR ADDITIONAL CABLES REQUIRED. CONTRACTOR SHALL ACCOUNT FOR AN ADDITIONAL 20% OF CABLES, DEVICES, AND PATCH PANELS INDICATED ON DRAWINGS IN ORDER TO ACCOMMODATE THE FULL SCOPE OF THE

PROJECT.

H. WITHIN BASE BID THE CONSTRUCTION SCHEDULE WILL BE IDENTIFIED BY THE CONSTRUCTION MANAGER. THE CONSTRUCTION TEAM SHALL DEVELOP A FINAL PHASING PLAN THAT WILL GENERALLY LIMIT SERVICE OUTAGES TO

CUTOVERS AND COMPLY WITH THE SCHEDULE SET FORTH BY THE VA.

I. REFER TO VA OIT "INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES VERSION 4.0" FOR ADDITIONAL REQUIREMENTS INCLUDING MANUFACTURER AND MODEL NUMBERS FOR THE BASIS OF DESIGN EQUIPMENT. ALL EQUIPMENT PROVIDED AS PART OF THIS PROJECT MUST BE EQUIVALENT TO THE BASIS OF DESIGN

EQUIPMENT LISTED.

J. COORDINATE STATUS OF ONGOING, PREVIOUS, AND PLANNED PROJECTS WITH THE VA FOR THE DURATION OF THIS PROJECT. ADJUSTMENTS TO THESE PLANS MAY BE REQUIRED TO COORDINATE WITH OTHER PROJECTS ON

THE VA CAMPUS.

K. FOR ALL DATA OUTLETS PROVIDE AND INSTALL NEW CONDUIT AND BACKBOX, REFER TO DETAIL FOR MORE

INFORMATION. CONDUIT SIZE SHALL BE MINIMUM OF 1-1/4 INCH

OR LARGER. FOR OUTLETS WITH GREATER THAN 4 CABLES, THE CONDUIT SIZE SHALL BE BASED ON 40% FILL

L. PROVIDE ONE (1) CATEGORY 6A CABLE TO EACH UPS WITHIN PROJECT. CENTRALIZED UPS'S ARE SHOWN ON THE ELECTRICAL DRAWING SET AND RACK MOUNTED UPS'S ARE SHOWN ON THE TELECOMMUNICATIONS ROOM RACK ELEVATIONS FOR EACH ROOM. UPS'S SHALL BE CONNECTED TOGETHER IN A CENTRALIZED UPS MONITORING

SYSTEM.

M. ALL CABLING, CONDUITS, CHASEWAYS, PANELS, BOXES AND EQUIPMENT ARE TO BE LABELED UTILIZING THE LATEST

IN BICSI/TIA STANDARDS.

N. ALL NEW CONSTRUCTION TRS ARE TO GET NEW ACCESS CONTROL PANELS FROM THE CURRENT VENDOR. THE CONTRACTOR WILL COORDINATE THE INSTALLATION OF THE NEW AC PANEL BY THE VENDOR WITH THE VA COR INTO

THE NEW TR.

O. IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE ALL ENTRANCE, BACKBONE, AND HORIZONTAL CABLING IS TERMINATED EACH END, TESTED, AND LABELED PER SPECIFICATIONS. FIBER OPTIC CABLING SHALL BE TERMINATED WITHIN RACK MOUNT FIBER ENCLOSURES EACH END. EXACT PART AND MODEL NO WILL NOT BE IDENTIFIED WITHIN RACK ELEVATIONS OR SCHEMATICS. REFER TO SPECIFICATIONS. UTP CABLING SHALL BE TERMINATED EACH END ON SPECIFIED CAT 6A PATCH PANELS WITHIN THE TRS AND SPECIFIED CAT 6A JACKS AT THE USER OUTLET.

P. EXISTING CEILINGS THROUGHOUT CORRIDORS AND ROOMS WITH EXISTING CABLING MAY NEED TO BE REMOVED AND REPLACED TO ACCOMMODATE CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR IDENTIFICATION OF SCOPE OF WORK ASSOCIATED WITH THIS REMOVAL AND INSTALLATION WITHIN BASE BID. WHERE EXISTING CEILINGS ARE LAYIN TILE, GRID SYSTEM MAY REMAIN IN PLACE AND ONLY THE EXISTING TILES WILL REQUIRE REMOVAL AND REPLACEMENT. EXISTING CEILING MOUNTED COMPONENTS SHALL BE TEMPORARILY SUPPORTED AND BE REINSTALLED IN NEW CEILINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR COST OF REPLACEMENT OF CEILING ELEMENTS THAT ARE DAMAGED OR DESTROYED DURING THE PROJECT. REFER TO ARCHITECTURAL DRAWINGS FOR FURTHER INFORMATION. COORDINATE WITH OWNER FOR PROCUREMENT OF REPLACEMENT CEILING TILES OR

OTHER ELEMENTS.

Q. EXISTING SYSTEMS THAT CURRENTLY HAVE A DATA CONNECTION (NURSE CALL, ACCESS CONTROL, TELEMETRY, ECT...) NEED TO BE RECONNECTED TO NEW TR ROOMS AS REQUIRED. CONTRACTOR TO INCLUDE PRICING FOR (75) CONNECTIONS TO LEGACY SYSTEMS, MANY REMAINING IN ABANDONED TR ROOMS. CONNECTIONS SHALL BE FIELD VERIFIED WHEN DECOMMISSIONING EXISTING CABLING. ALL ACTIVE COMPONENTS WITH AN EXISTING DATA CABLE

SHALL RECEIVE A NEW CABLE CONNECTION TO THE NEW TR ROOM SERVING THAT AREA.

R. FOR MAIN CABLE ROUTES WITHIN CORRIDORS, THE CONTRACTOR SHALL ASSUME THAT ALL WALLS WILL REQUIRE NEW SLEEVES TO ALLOW FOR NEW HORIZONTAL CABLING TO BE ROUTED PRIOR TO REMOVING EXISTING HORIZONTAL CABLING. SLEEVES THROUGH RATED WALLS SHALL INCLUDE LISTED FIRE STOP. SLEEVE

REQUIREMENTS INDICATED PER SPECIFICATION.

S. ALL HORIZONTAL CABLING AND THEIR PATHWAYS PASSING THROUGH A WALL, RATED FIRE OR SMOKE BARRIER MUST BE PROPERLY SLEEVED AND FIRE STOPPED USING APPROVED (UL CLASSIFIED) FIRE STOP ASSEMBLIES AS REQUIRED FOR THE WALL RATING. FIRESTOP ASSEMBLIES ARE TO BE INSTALLED PER THE MANUFACTURER ’S

INSTRUCTIONS FOR THE TYPE OF BARRIER, PATHWAY SIZE, AND QUANTITY OF CABLES.

T. THE CONTRACTOR SHALL INCLUDE IN THEIR BID THE QUANTITY OF SLEEVES REQUIRED FOR A COMPLETE

INSTALLATION.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TELECOMMUNICATIONS GENERAL NOTES:

PHASING GENERAL NOTES:

A. PHASING SEQUENCE LISTED BELOW IS FOR INFORMATION ONLY. CONTRACTOR SHALL BE RESPONSIBLE

FOR DEVELOPING PROJECT SCHEDULE AND PHASING AND SHALL INCLUDE WORK REQUIRED TO

ACCOMMODATE PHASING. SUBMIT PHASING PLAN TO OWNER FOR REVIEW AND APPROVAL AND

COORDINATE WITH OWNER PRIOR TO BEGINNING CONSTRUCTION. REFER TO PHASING APPENDIX FOR

ADDITIONAL INFORMATION.

B. SITE FIBER TO BUILDINGS: CONSTRUCT REDUNDANT SITE FIBER LOOP FROM MAIN COMPUTER ROOM TO ALL BUILDINGS. MAINTAIN EXISTING FIBER PATHWAYS FROM THE EXISTING MAIN COMPUTER ROOM UNTIL NEW TELECOMMUNICATION ROOMS ARE CONSTRUCTED WITH A SIDE FIBER PULLED. DEMOLISH EXISTING B

SIDE FIBER AND UTILIZE NEW DUCT BANK TO PULL NEW B SIDE FIBER.

C. NEW TELECOMMUNICATIONS ROOMS AND RESUPPORTED EXISTING TELECOMMUNICATIONS ROOMS:

CONSTRUCT NEW TELECOMMUNICATIONS ROOMS TO BE OPERATIONAL. RESUPPORT EXISTING

TELECOMMUNICATIONS ROOMS TO REMAIN WITH NEW RACKS AND BACKBONE CABLING. PROVIDE NEW A/B

POWER PANELS AND GROUNDING IN NEW AND EXISTING TO REMAIN ROOMS. POWER ALL

TELECOMMUNICATIONS ROOM LOADS FROM THE NEW PANELS. ROUTE NEW PRIMARY AND REDUNDANT FIBER TO NEW TELECOMMUNICATIONS ROOMS AND EXISTING TO REMAIN TELECOMMUNICATIONS ROOMS, FROM THE MAIN COMPUTER ROOM . UPON ACTIVATION OF THESE NEW AND RESUPPORTED ROOMS, BOTH THE NEW AND EXISTING DISTRIBUTION NETWORKS WILL BE SIMULTANEOUSLY ACTIVE TO ALLOW FOR RE- CABLING THE PROGRESSIVE TRANSITION FROM THE EXISTING NETWORK TO THE NEW NETWORK FOR EACH AREA OUTLET INDIVIDUALLY. EXISTING FIBER UTILIZING EXISTING PATHWAYS SHALL NOT BE REMOVED UNTIL

NEW FIBER ROUTE B IS COMPLETE AND NEW TELECOMMUNICATIONS ROOMS ARE ONLINE AND

FUNCTIONING.

D. EXISTING TELECOMMUNICATIONS ROOMS: MAINTAIN THE EXISTING TELECOMMUNICATIONS ROOMS AND

EXISTING BACKBONE CABLING UNTIL THE AREA OUTLETS BEING SERVED BY EACH RESPECTIVE

TELECOMMUNICATIONS ROOM HAS BEEN TRANSITIONED TO THE NEW TELECOMMUNICATIONS ROOM.

E. RE-CABLING: FOR NEW TELECOMMUNICATIONS ROOMS, PROVIDE NEW CABLES FROM THE EXISTING AREA OUTLETS TO THE NEW RACKS. REMOVE EXISTING CABLING AFTER NEW CABLES HAVE BEEN PULLED TO THE OUTLETS TO MAINTAIN OPERATIONAL CAPABILITY OF THE SPACES TO THE GREATEST EXTENT POSSIBLE.

F. EXISTING CABLE REMOVAL: AFTER NEW CABLING HAS BEEN INSTALLED AND ACTIVATED, REMOVE EXISTING BACKBONE CABLING AND EXISTING AREA OUTLET CABLING FROM TELECOMMUNICATIONS ROOMS BEING ABANDONED. REMOVE UNUSED CABLING IN PREVIOUSLY ABANDONED TELECOMMUNICATIONS ROOMS.

G. NETWORK ELECTRONICS COORDINATION: CONSIDERING THE ABOVE PHASING, COORDINATION WILL BE

REQUIRED BETWEEN THE VA AND CABLING CONTRACTOR IN ORDER TO PROPERLY

SEQUENCE THE ACQUISITION, CONFIGURATION, AND ACTIVATION OF NETWORK ELECTRONICS IN COORDINATION WITH THE ACTIVATION OF EACH NEW NETWORK DISTRIBUTION POINT, ACTIVATION OF EACH RE-CABLED OUTLET, AND THE SUBSEQUENT DEACTIVATION OF BOTH EXISTING OUTLET CABLES AND EXISTING NETWORK DISTRIBUTION POINTS. SWITCHES SHALL BE PROVIDED BY OWNER OTHER EQUIPMENT

BY CONTRACTOR.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

PRICING / PROJECT GENERAL NOTES:

A. CABLE DISTANCE PLANS ARE SHOWN FOR REFERENCE / VA REQUIREMENT ONLY. CONTRACTOR IS RESPONSIBLE FOR DETERMINING WHICH ROOM WORK AREA OUTLETS ARE CABLED TO. CABLE DISTANCE

SHOWS THE MAXIMUM DISTANCE A CABLE SHALL BE RUN.

B. TELECOMMUNICATIONS GROUNDING SCOPE TO BE VERIFIED WITH OTHER TRADES. A COMPLETE

TELECOMMUNICATIONS GROUNDING SCHEME SHALL BE PROVIDED.

C. CABLE TRAY IS SHOWN AS NEW SHALL BE PRICED FOR THE ENTIRE PROJECT. DUE TO LIMITED CEILING SPACE SOME AREAS SHALL TRANSITION FROM CABLE TRAY TO J HOOKS. EXISTING CABLE TRAY SHALL BE DEMOLISHED IN AREAS WHERE NEW CABLE TRAY IS PROVIDED. THE EXISTING CABLE TRAY MAY BE UTILIZED OR REPLACED IN THE SAME LOCATION IN AREAS WHERE IT IS NOT POSSIBLE TO PROVIDE NEW.

D. COORDINATION WITH THE CONCURRENT MCR PROJECT SHALL BE REQUIRED FOR FINAL FIBER LENGTH

TERMINATIONS AND LOCATION.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

PENETRATION COORDINATION NOTE

A. ALL FLOOR PENETRATIONS TO BE COORDINATED WITH EXISTING STRUCTURE. CONTRACTOR TO LOCATE (E) REINFORCING PRIOR TO PROCEEDING WITH CORE, IF REINFORCING MUST BE CUT CONTRACTOR TO SUBMIT EXISTING REINFORCING LAYOUT AND PROPOSED CORE LOCATION TO VA FOR REVIEW AND APPROVAL. MAX CORE SIZE IS 4-1/2”Ø. CONTRACTOR TO PROVIDE 1” CLEAR FROM (E) PAN JOIST. AND 6” CLEAR FROM ADJACENT PENETRATIONS. FLOOR PENETRATIONS ARE NOT PERMITTED ON BOTH SIDES OF THE SAME

JOIST.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

LABELING COORDINATION NOTE

A. ALL CABLES/FIBER SHALL BE LABELED AT BOTH ENDS AND AT ANY SPLICES PER THE LOCAL NAMING

CONVENTION..

B. ALL DATA DROPS AND WAO SHALL BE LABELED BY BUILDING # - ROOM # - PATCH PANEL # - PORT #

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TELECOMMUNICATIONS ABBREVIATIONS

ABBREVIATION DESCRIPTION

REFER TO OTHER SCHEDULES AND NOTES FOR ADDITIONAL ABBREVIATIONS.

MOUNTING HEIGHT TO CENTERLINE (ABOVE FINISHED FLOOR)

AMPERE

AMPERE FRAME

ABOVE FINISHED FLOOR

ALUMINUM

AMPERE TRIP

CEILING

CIRCUIT BREAKER

CORRELATED COLOR TEMPERATURE

COPPER

DATA (WHEN APPLIED TO COMMUNICATIONS OUTLET)

DEMO (WHEN APPLIED TO EXISTING/DEMO ITEMS)

EXISTING

ELECTRICALLY OPERATED

ENERGY REDUCING MAINTENANCE SWITCH

FUSE

FULL LOAD AMPS

GROUND FAULT CIRCUIT INTERRUPTER

GROUND FAULT ALARM

GROUND FAULT PROTECTION

HORSEPOWER

KILOAMPERE INTERRUPTING CAPACITY

KILOVOLT AMPERE

KILOWATT

MAXIMUM

MINIMUM CIRCUIT AMPS

MAIN CIRCUIT BREAKER

MINIMUM

MAIN LUGS ONLY

MANUALLY OPERATED

NORMALLY CLOSED

NON-FUSED

NOT IN CONTRACT

NORMALLY OPEN

POLES

PARTIAL

RELOCATE

SHORT CIRCUIT CURRENT RATING

SURGE PROTECTIVE DEVICE

SHUNT TRIP

TYPICAL

UNLESS NOTED OTHERWISE

VOICE

WALL PHONE

WIRE

WEATHER RESISTANT

TRANSFORMER

ZONE SELECTIVE INTERLOCKING

A

AF

AFF

AL

AT

C

CB

CCT

CU

D

D

E

EO

ERMS

F

FLA

G, GFCI

GFA

GFP

HP

KAIC

KVA

KW

MAX

MCA

MCB

MIN

MLO

MO

NC

NF

NIC

NO

P

PART

R

SCCR

SPD

ST

TYP

UNO

V

W

W

WR

XFMR

ZSI

LEGEND: (LOW VOLTAGE COORDINATION LEGEND)

CF: CONTRACTOR FURNISHED

CI: CONTRACTOR INSTALLED

OF: OWNER FURNISHED

OI: OWNER INSTALLED

REMARKS: (LOW VOLTAGE COORDINATION LEGEND)

1. PATCH PANELS SHALL BE CONTRACTOR FURNISHED AND CONTRACTOR INSTALLED PER SPECIFICATION. REFER TO

TYPICAL COMMUNICATION TERMINATION DETAIL.

2. ACCESS CONTROL IS AN EXTENSION OF AN EXISTING SYSTEM. NEW DEVICES SHALL FUNCTION AS AN EXTENSION OF

THE EXISTING SYSTEM. CONTRACTOR TO VERIFY WITH VA COR FOR ADDITIONAL LICENSE REQUIREMENTS.

3. FIRE ALARM SYSTEM IS AN EXTENSION OF AN EXISTING SYSTEM. NEW DEVICES SHALL FUNCTION AS AN EXTENSION OF

THE EXISTING SYSTEM.

4. NOT USED.

5. PROVIDE VIDEO SURVEILLANCE FOR EACH TELECOMMUNICATION SPACE AS PART OF AN APC NETBOTZ 750 OR

EQUIVALENT ROOM MONITOR SYSTEM.

6. TEMPERATURE MONITORING IS AN EXTENSION OF AN EXISTING SYSTEM. NEW DEVICES SHALL FUNCTION AS AN

EXTENSION OF THE EXISTING SYSTEM. PROJECT SCOPE INCLUDES RE CABLING EXISTING SYSTEMS AS REQUIRED AND

CABLING FOR NEW TR SPACE MONITORS.

7. TELEVISION SYSTEM TO RECABLED WHERE EXISTING SYSTEM IS CATEGORY 5E OR BELOW OR WHERE EXISTING TR

ROOM IS BEING ABANDONED. NO TELEVISION EQUIPMENT IS ANTICIPATED IN SCOPE.

8. WIRELESS ACCESS POINTS TO BE RECABLED WHERE EXISTING CABLING IS CATEGORY 5E OR BELOW OR WHERE EXISTING TELECOMMUNICATIONS ROOM IS BEING ABANDONED. NO NEW WIRELESS ACCESS POINTS ARE ANTICIPATED

IN SCOPE.

GENERAL NOTES: (LOW VOLTAGE COORDINATION LEGEND)

A. REFER TO SYMBOL LEGENDS AND SPECIFICATIONS FOR SPECIFIC REQUIREMENTS.

B. COORDINATE ROUGH-IN REQUIREMENTS WITH FINAL EQUIPMENT SELECTION FOR ALL SYSTEMS.

C. COORDINATE ROUGH-IN REQUIREMENTS WITH OWNER FOR OWNER FURNISHED SYSTEMS.

D. CONDUITS SHALL ROUTE CONCEALED INSIDE WALL TO ABOVE NEAREST ACCESSIBLE CEILING SPACE, UNLESS OTHERWISE INDICATED.

E. WHERE CABLING IS CONTRACTOR FURNISHED AND CONTRACTOR INSTALLED, TERMINATE AND TEST ALL CABLING PER SPECIFICATION.

A. THE INTENT OF THE DEMOLITION DRAWINGS IS TO DEFINE THE SCOPE OF DEMOLITION WORK. PROVIDE

DEMOLITION FOR ITEMS AS SHOWN.

B. ITEMS INDICATED WITH A SUBSCRIPT 'E' SHALL BE EXISTING TO REMAIN (E-EXISTING). ITEMS INDICATED WITH A SUBSCRIPT 'D' OR SHOWN DASHED SHALL BE REMOVED (D-DEMOLITION). ITEMS INDICATED WITH A SUBSCRIPT 'R'

SHALL BE REMOVED, STORED, AND REINSTALLED PER NEW WORK (R-RELOCATION).

C. THESE DRAWINGS DO NOT IDENTIFY EACH INDIVIDUAL ITEM TO BE REMOVED. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING ITEMS WHICH MUST BE REMOVED TO FACILITATE NEW CONSTRUCTION. SEE ARCHITECTURAL PLANS FOR EXACT LIMITS OF DEMOLITION AND CONSTRUCTION. THESE PLANS ARE BASED ON PAST PROJECT DRAWINGS AND SITE OBSERVATIONS. THE DRAWINGS ARE PROVIDED TO THE CONTRACTOR AS AN AID IN DETERMINING THE EXTENT OF WORK REQUIRED FOR DEMOLITION AND TO PROVIDE GENERAL INFORMATION ABOUT EXISTING SYSTEMS. THESE DRAWINGS MAY NOT BE ACCURATE IN ALL AREAS. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS AND IS ENCOURAGED TO REVIEW FACILITY

DRAWINGS PRIOR TO THE BID DATE.

D. THE OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ALL ITEMS REMOVED. IF OWNER REFUSES SALVAGE, CONTRACTOR IS RESPONSIBLE FOR DISPOSAL.

E. WHERE EXISTING WALLS ARE TO BE REMOVED, ALL ASSOCIATED TELECOMMUNICATIONS EQUIPMENT SHALL BE REMOVED. DISCONNECT POWER SO THAT DEVICES AND EQUIPMENT MAY BE REMOVED WITH WALLS. SEE ARCHITECTURAL DRAWINGS FOR WALLS TO BE REMOVED. ABANDON CONCEALED CONDUITS WHERE WALLS ARE NOT REMOVED.. WHERE EXISTING CIRCUITING/CABLING IS TO BE DEMOLISHED AND NOT REUSED, REMOVE CABLES AND ASSOCIATED ACCESSIBLE RACEWAYS/CONDUIT BACK TO THE SOURCE. WHERE EXISTING ELECTRICAL CONDUITS SERVING CIRCUITS TO BE DEMOLISHED ARE EMBEDDED IN CONCRETE FLOORS OR WALLS, CONDUITS MAY BE ABANDONED IN PLACE. EXISTING CONDUCTORS SHALL BE REMOVED BACK TO SOURCE AND CONDUITS SHALL BE CUT AT SURFACE OF CONCRETE AND FILLED. REMOVE AND PATCH WHERE BOXES ARE NOT REUSED.

F. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS. DISCONNECT AND REMOVE TELECOMMUNICATIONS DEVICES, EQUIPMENT AND ASSOCIATED WIRING AS REQUIRED TO ACCOMMODATE NEW WORK. IF THE CONTRACTOR IS UNCLEAR REGARDING A SPECIFIC ITEM TO REMAIN OR BE REMOVED, THE

CONTRACTOR SHALL SEEK CLARIFICATION FROM THE COR/DESIGN TEAM.

G. SYSTEMS SERVING ADJACENT AREAS AND ITEMS THAT REMAIN SHALL BE MAINTAINED AT ALL TIMES. MODIFY SYSTEMS AS REQUIRED THROUGHOUT CONSTRUCTION TO MAINTAIN CONTINUITY OF SERVICE. DO NOT INTERRUPT SERVICE WITHOUT OWNER'S PRIOR WRITTEN APPROVAL. LIMIT DURATION OF INTERRUPTION ONLY TO THE TIME NECESSARY FOR DISCONNECTION AND IMMEDIATE RECONNECTION. INTERRUPTION TO SERVICE DEEMED BY OWNER AS ESSENTIAL MAY REQUIRE PREMIUM TIME AND SHALL BE INCLUDED WITH THE BID. EXTREME CARE SHALL BE TAKEN BY THE CONTRACTOR TO IDENTIFY EXISTING SYSTEM COMPONENTS ASSOCIATED WITH THESE SERVICES. APPROPRIATE METHODS OF MARKING THESE SHALL OCCUR TO ELIMINATE THE POSSIBILITY OF ACCIDENTAL INTERRUPTION. FOR CONDUIT AND CABLING THAT CAN REMAIN, PROVIDE SUPPORT AS REQUIRED.

RELOCATE EXISTING JUNCTION BOXES THAT BECOME INACCESSIBLE DUE TO NEW WORK.

H. COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES.

I. PROTECT EXISTING EQUIPMENT THAT REMAINS. IF DAMAGED OR DISTURBED IN THE COURSE OF THE WORK, REMOVE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL CAPACITY, QUALITY, AND FUNCTIONALITY.

J. PATCH AND REPAIR OPENINGS IN EXISTING WALLS AND FLOORS RESULTANT FROM SPECIFIED DEMOLITION. PATCH

SHALL MATCH EXISTING CONSTRUCTION, FIRE RATING, AND FINISH. SEE ARCHITECTURAL SPECIFICATIONS FOR

MEANS AND METHODS.

K. THIS PROJECT WILL BE PHASED. SEE PROJECT MANUAL AND ARCHITECTURAL PLANS FOR DETAILS. SYSTEM SERVICES TO AREAS NOT IN THE CURRENT PHASE OF CONSTRUCTION SHALL BE MAINTAINED AT ALL TIMES.

L. WHERE DEMOLITION OF EQUIPMENT INVOLVES REMOVAL OF EQUIPMENT LOCATED ON CONCRETE HOUSEKEEPING PADS, PADS SHALL ALSO BE REMOVED AND FLOOR/GRADE SHALL BE FINISHED TO MATCH ADJACENT SURFACE.

M. ALL UNLABELED DEVICES THAT EXIST IN ALL ROOMS WHERE THERE IS WORK WITHIN SCOPE SHALL BE CIRCUIT

TRACED AS NEEDED WITH A LABEL PROVIDED.

N. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF ALL CABLING, PATHWAYS, AND SYSTEMS LOCATED ABOVE CEILING THAT ARE REQUIRED TO BE MODIFIED AS A PART OF THE PROJECT. CONTRACTOR SHALL REPLACE

ANY ITEMS DAMAGED FROM TEMPORARY SUPPORT.

O. EXISTING ANALOG DEVICES ACTIVELY SERVING EQUIPMENT SHALL BE EXISTING TO REMAIN REGARDLESS IF SHOWN AS BEING REMOVED. CONNECTIONS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING. THE

CONTRACTOR SHALL FIELD VERIFY DURING CONSTRUCTION

a. ACTIVE COPPER VOICE LINES, FAX, ELEVATORS, PATIENT TELEPHONES, BLUE PHONES, CODE BLUE DEVICES, FIRE ALARM, MEDICAL ANALOG EQUIPMENT, PANIC DURESS, ETC.

b. ANALOG DEVICES NOT ACTIVE SHALL BE REMOVED.

P. WITHIN EXISTING SPACES THAT ARE DEMOLISHED TO BE CONVERTED INTO A TR, REROUTE ANY EXISTING LOW VOLTAGE CABLING OUTSIDE THE ROOM AND RECABLE AND RECONNECT TO THE NEW TR ROOM.

Q. ALL CATEGORY 5E AND LOWER DATA CABLES THAT ARE REMOVED FROM THE RACK ARE TO BE REMOVED ENTIRELY TO THE WORK AREA. THE WORK AREA WALL PLATES, RACEWAYS AND JACKS ARE ALSO PART OF THE DEMOLITION. OLD DATA CABLES CANNOT BE DEMOLISHED UNTIL NEW CAT6A CABLES HAVE BEEN INSTALLED AND THE CLIENT IS ACTIVELY USING THE NEW DATA DROP. SEE THE PHASING NOTES FOR ADDITIONAL DETAIL.

R. ALL DEMO'D EQUIPMENT MUST BE TURNED IN BY AN OIT / ENGINEERING / SUPPLY REPRESENTATIVE TO ENSURE

REMOVAL FROM ALL INVENTORY LIST.

S. FIBER CABLES THAT ARE IN TRS TO BE DEMOLISHED ARE TO BE REMOVED ENTIRELY BACK TO THE SERVER ROOM.

ANY CONDUIT USED BY THE EXISTING FIBER WILL BE REMOVED. FIBER IN TRS THAT WILL NOT RELOCATE IS TO BE

REMOVED AFTER NEW REDUNDANT PATHS ARE INSTALLED.

T. EXISTING NURSE CALL / BIOMED SYSTEMS ARE TO REMAIN IN EXISTING CLOSETS. EXISTING TO REMAIN EQUIPMENT

SHALL BE RECABLED TO NEW TR ROOM. COORDINATE ANY OUTAGES WITH VA COR.

(TELECOMMUNICATIONS DEMOLITION NOTES APPLY TO ALL TELECOMMUNICATIONS

DEMOLITION PLANS AND ALL TELECOMMUNICATIONS DEMOLITION WORK)

TELECOMMUNICATIONS DEMOLITION GENERAL NOTES:

(GENERAL NOTES APPLY TO ALL SHEETS)

A. WORK RESTRICTIONS IN OPERATIONAL ROOMS: WORK WITHIN EXISTING ROOMS

(ENTRANCE FACILITY, MAIN COMPUTER ROOMS, TELECOMMUNICATIONS ROOMS)

SHALL REQUIRE THE PRESENCE OF A VA ESCORT WHILE THE EXISTING ROOM IS

STILL OPERATIONAL AND ACTIVE. WORK WITHIN NEW ROOMS (ENTRANCE FACILITY,

MAIN COMPUTER ROOM, TELECOMMUNICATIONS ROOMS) SHALL REQUIRE THE

PRESENCE OF A VA ESCORT ONCE THE NEW ROOM BECOMES OPERATIONAL AND

ACTIVE.

B. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR WORK

RESTRICTIONS WITHIN EACH BUILDING FOR TIME OF DAY AVAILABILITY OF SPACES

AND LEVEL OF INFECTION CONTROL REQUIRED BY THE CONTRACTOR. CONTRACTOR

SHALL ACCOUNT FOR OFF HOURS WORK REQUIRED.

C. REFER TO PHASING APPENDIX FOR ADDITIONAL REQUIREMENTS.

WORK RESTRICTION GENERAL NOTES:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

7100 E BELLEVIEW AVE,

STE 107

GREENWOOD VILLAGE,

CO 80111

Phone: (720) 200-5955 www.specializedeng.com

SES Project : 22295

330 N. Mead St, Suite 100 Wichita, KS 67202

Phone: (316) 262-2500 www.hfgarchitecture.com

A u to d e s k D o c s /2

V

A G ra n d J u n c ti o n

E H

R M

/5

-7

.B

.E

T .R

.r v t

/2

/2

:3

:4

A

M

TN000

TELECOMMUNICATIONS SYMBOLS AND

ABBREVIATIONS

EHRM IU AT THE GRAND JUNCTION,

CO VA MEDICAL CENTER

2121 North Ave, Grand Junction, CO 81501

575-21-700

12/17/2024 RJA CMW

COMMUNICATION SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

4 POST COMMUNICATIONS RACK PROVIDE 7'-0" TALL 45U, 4 POST TELECOMMUNICATIONS CHANNEL RACK AT APPROXIMATE LOCATIONS INDICATED ON FLOOR PLANS. PROVIDE MIGHTY MO 20 CABLE MANAGEMENT RACK 30" DEPTH, WHITE FINISH MODEL NUMBER:

OR-MM2073038-W (OR PRIOR APPROVED EQUIVALENT) WITH VERTICAL CABLE MANAGEMENT OR-MM20VMD706 (OR PRIOR APPROVED EQUIVALENT). REFER TO FLOOR PLANS FOR DATA SWITCH ELECTRICAL SOURCE AND REQUIREMENTS. PROVIDE TELECOMMUNICATIONS RACK AND ALL ACCESSORIES PER SPECIFICATION SECTION 271100 AND OIT DESIGN GUIDE RACK EQUIPMENT SPECIFICATIONS. PROVIDE ALL ACCESSORIES FOR A COMPLETE

INSTALLATION, INCLUDING BUT NOT LIMITED TO: BRACKETS,

MOUNTING FRAMES, HORIZONTAL AND VERTICAL WIRE MANAGEMENT, AND GROUNDING CONNECTIONS.

PROVIDE WITH RACK MOUNTED PDU:

APC AP8861 RPDU (OR PRIOR APPROVED EQUIVALENT); RACK PDU 2G, METERED; L21-20 PLUG; THREE PHASE;120/208V INPUT; 20A; ZERO U, 5.7 KW, 208V, (36) C13 & (6) C19 & (2) 5-20 OUTLETS; A-SIDE BLACK, B-SIDE

WHITE OR OTHER DISTINCTIVE COLOR.

WHERE INDICATED ON PLANS PROVIDE:

EATON BLADE UPS ZC0517700110000 (OR PRIOR APPROVED EQUIVALENT), RACK-MOUNTED 5 KW, 6RU, 19" RACK-MOUNTABLE, 208V UNINTERRUPTIBLE POWER SUPPLY (UPS) WITH NEMA 20A L21-20P INPUT AND L21-20R

OUTPUT.

REFER TO VA OIT "INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES VERSION 3.1" FOR ALL COMPONENT REQUIREMENTS. COORDINATE EXACT FINAL LOCATION WITH OWNER'S IT REPRESENTATIVE PRIOR TO INSTALLATION. PROVIDE ALL POWER CONNECTIONS INDICATED ON FLOOR PLANS AT FINAL RACK LOCATION. REFER

TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

COMMUNICATIONS FIRE RATED

PATHWAY – WALL

PROVIDE STI FIRESTOP EZ-PATH COMMUNICATIONS FIRE RATED PATHWAY AT LOCATIONS INDICATED ON FLOORPLANS. MOUNT PATHWAYS ABOVE ACCESSIBLE CEILING SPACES. COORDINATE MOUNTING HEIGHT WITH CABLE TRAY, TELECOMMUNICATION RACK HEIGHTS, CEILING, AND OTHER TRADES. INSTALL PER MANUFACTURERS RECOMMENDATIONS. COORDINATE REQUIRED WALL OPENING WITH STUD SPACING. REFER TO FLOOR PLANS FOR

PATHWAY TYPE AND QUANTITIES. PROVIDE PATHWAY TYPES AS INDICATED BELOW.

(A1) - FULL KIT CATALOG # EZDP133CWK (1-3"x3" PATHWAY) (A2) - FULL KIT CATALOG # EZDP233GK (2-3"x3" PATHWAYS) (A3) - FULL KIT CATALOG # EZDP333GK (3-3"x3" PATHWAYS) (A4) - FULL KIT CATALOG # EZDP433GK (4-3"x3" PATHWAYS) (A7) - FULL KIT CATALOG # EZDP733GK (7-3"x3" PATHWAYS) (A8) - TWO (2) FULL KIT CATALOG # EZDP433GK (8-3"x3" PATHWAYS) (STACKED) (B1) - FULL KIT CATALOG # EZD22 (1-2"x2" PATHWAY) (C1) - FULL KIT CATALOG # EZDP44S2 (1-4"x4" PATHWAY) (C2) - TWO (2) MODULE CATALOG # EZD44S2 & ONE (1) EZP544W (2-4"x4" PATHWAYS) (C3) - THREE (3) CATALOG # EZD44S2 & ONE (1) EZP544W (3-4"x4" PATHWAYS) (C4) - FOUR (4) CATALOG # EZD44S2 & ONE (1) EZP544W (4-4"x4" PATHWAYS) (REQUIRES 16" STUD SPACING) (C5) - FIVE (5) CATALOG # EZD44S2 & ONE (1) EZP544W (5-4"x4" PATHWAYS) (REQUIRES 24" STUD SPACING)

PROVIDE STI FIRESTOP EZ-PATH CABLE SPILLWAY AT LOCATIONS INDICATED ON FLOORPLANS WITH SUBSCRIPT 'S'.

PROVIDE ONE (1) SPILLWAY PER SLEEVE. REFER TO FLOORPLANS FOR SPILLWAY TYPE AND QUANTITIES.

(A#S) - CATALOG NO. RCM33

(C#S) - CATALOG NO. EZRCM44S

PROVIDE STI FIRESTOP EZ-PATH EXTENSION MODULES AT LOCATIONS INDICATED ON PLANS WITH SUBSCRIPT 'E'.

PROVIDE ONE (1) EXTENSION MODULE PER SLEEVE. WHERE PATHWAY IS INDICATED WITH SUBSCRIPT 'EE', PROVIDE ONE (1) EXTENSION MODULES ON EACH END. REFER TO FLOORPLANS FOR EXTENSION MODULE TYPE AND

QUANTITIES.

(A#E) - CATALOG NO. EZD33E

(C#E) - CATALOG NO. EZD44ES

PLYWOOD BACKBOARD PROVIDE 3/4" THICK X 4' WIDE X 8' HIGH A/C GRADE FIRE-RETARDANT TREATED PLYWOOD BACKBOARD AT APPROXIMATE LOCATION INDICATED. REFER TO FLOORPLANS FOR WIDTHS. CUT ADDITIONAL PLYWOOD TO FIT APPROXIMATE WIDTH INDICATED ON FLOORPLANS. MOUNT PLYWOOD VERTICALLY. BUTT ADJACENT SHEETS TIGHTLY, AND FORM SMOOTH GAP-FREE CORNERS AND JOINTS. PROVIDE WITH TWO (2) COATS OF WHITE PAINT ON ALL FACES AND EDGES. PROVIDE WITH LABEL ON EACH SHEET OF PLYWOOD WITH FIRE RATINGS, VISIBLE

AFTER PAINTING. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

TELECOMMUNICATIONS

GROUND BAR

PROVIDE LENGTH AS REQUIRED TO ACCOMMODATE TERMINATIONS, MINIMUM 10" IN LENGTH. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

DATA SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

COMMUNICATIONS OUTLET -

WALL

GENERAL:

PROVIDE COMMUNICATIONS OUTLET AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH OUTLET TYPE. REFER TO PLANS FOR OUTLET DESIGNATION AND QUANTITIES OF NETWORK VOICE/DATA CABLES TO BE PROVIDED TO OUTLET FROM ASSOCIATED NEAREST TR ROOM. PROVIDE ROUGH-IN , RACEWAYS AND CABLING.

PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATIONS INCLUDING, BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, JACKS, INSERTS, FACEPLATES, AND CABLING. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT FINAL LOCATION WITH EXISTING BOXES. PROVIDE CABLING AS LISTED BELOW. OUTLETS WITH NO CABLING DESIGNATION SHALL BE EMPTY WITH A BLANK WALL PLATE. CABLING DESIGNATIONS ARE TYPICAL FOR ALL WALL, FLOOR, AND CEILING COMMUNICATIONS DEVICES. REFER TO

SPECIFICATIONS FOR CABLING REQUIREMENTS FOR EACH TYPE.

-A = ONE (1) ANALOG VOICE CABLE

-V = ONE (1) VOICE CABLE

-D = ONE (1) DATA CABLE

ON DEMOLITION PLANS THE QUANTITY SHOWN IS FOR PRICING THE QUANTITY OF CABLES TO REMVOE. RECABLED OUTLET'S CABLING SHALL UTILIZE ENTIRELY NEW RACEWAYS WITH THE EXCEPTION OF CABLE TRAY DEEMED

ACCEPTABLE TO REMAIN.

SECURITY SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

ACCESS CONTROL DEVICE GENERAL:

PROVIDE ACCESS CONTROL COMPONENTS AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH ACCESS CONTROLLED DEVICE TYPE AT DOORS INDICATED. REFER TO FLOOR PLANS FOR DEVICE DESIGNATION. PROVIDE ROUGH-INS PER ACCESS CONTROL ROUGH-IN DETAIL. DOOR ACCESS COMPONENTS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION. COORDINATE REQUIRED CONDUITS TO DOOR FRAME AND WALL MOUNTED DEVICES WITH DOOR HARDWARE CONTRACTOR. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS.

PROVIDE 20A 120V EQUIPMENT BRANCH CIRCUIT TO DOOR CONTROLLERS LOCATED WITHIN ACCESS CONTROL CABINET IN ASSOCIATED TR ROOM. PROVIDE FINAL CONNECTION OF 120V BRANCH CIRCUIT TO ALL POWER SUPPLIES REQUIRED FOR EACH DOOR FUNCTION. REFER TO FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS.

PROVIDE ACCESS CONTROL CABLING FROM DOOR CONTROLLER TO COMPONENTS REQUIRED BY THE DOOR HARDWARE SPECIFICATION INCLUDING BUT NOT LIMITED TO CARD READER, DOOR POSITION SWITCH, ELECTRIC STRIKE, ELECTRIFIED HINGE, DOOR RELEASE PUSH BUTTON, AND REQUEST TO EXIT. PROVIDE DOOR POSITION SWITCH AND REQUEST TO EXIT AT EACH ACCESS CONTROLLED DOOR, UNLESS PROVIDED BY DOOR HARDWARE CONTRACTOR. COORDINATE ALL TERMINATION REQUIREMENTS AND EXACT LOCATION OF TERMINATIONS WITH OWNER'S ACCESS CONTROL MANAGER. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM PER SPECIFICATION SECTION INCLUDING BUT NOT LIMITED TO INSTALLATION, CONFIGURATION, DEVICES, AND CABLING. WHERE DOOR IS ALSO SPECIFIED/SHOWN TO UTILIZE DOOR OPERATOR, PROVIDE INTERLOCK TO ALLOW AUTOMATIC DOOR OPENING FROM THE ACCESS CONTROL SYSTEM UPON SUCCESSFUL CARD READ.

SUBMIT SHOP DRAWINGS FOR APPROVAL. PROVIDE FIRE ALARM SYSTEM CONNECTION FOR DOOR RELEASE UPON ALARM. INTEGRATE ACCESS CONTROL SYSTEM WITH DOOR OPERATORS, FIRE ALARM, WANDER PREVENTION, INFANT PROTECTION, INTERCOM, AND DOOR HARDWARE. REFER TO ACCESS CONTROL AND ARCHITECTURAL DOOR HARDWARE SPECIFICATIONS FOR COORDINATION OF FEATURES, DEVICES, AND CONNECTIONS REQUIRED.

ACCESS CONTROL PANEL CIRCUIT CONTROL PANEL TO 20A 120V BRANCH CIRCUIT IN LOCAL A SIDE TR ROOM BRANCH PANEL OF THE ASSOCIATED CONSTRUCTION PHASE. REFER TO FLOOR PLANS FOR BRANCH CIRCUIT DESIGNATIONS.

COORDINATE CONNECTION REQUIREMENTS WITH FINAL EQUIPMENT SELECTION AND PROVIDE NEMA 5-20

RECEPTACLE OR HARD-WIRED CONNECTION TO CABINET AS REQUIRED.

CREDENTIAL CARD READER GENERAL:

PROVIDE PROXIMITY CARD READER [AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH CARD READER TYPE] AT APPROXIMATE LOCATION INDICATED. [REFER TO FLOOR PLANS FOR CARD READER DESIGNATION.] PROVIDE ROUGH-IN PER ACCESS CONTROL ROUGH-IN DETAIL. WHERE SHOWN MOUNTED ON DOOR/WINDOW SYSTEM MULLION, PROVIDE MULLION MOUNT CARD READER SURFACE MOUNTED ON MULLION.

CABLING SHALL BE ROUTED RECESSED WITHIN MULLION TO ACCESSIBLE CEILING SPACE. COORDINATE INSTALLATION WITH MULLION MANUFACTURER. CARD READERS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATION SECTION 281300. SUBMIT SHOP DRAWINGS FOR APPROVAL. COORDINATE EXACT LOCATION OF CARD READER WITH ARCHITECT, ARCHITECTURAL INTERIOR ELEVATIONS, AND OTHER DOOR COMPONENTS INCLUDING BUT NOT LIMITED TO PUSH PLATE ACTUATORS, REQUEST TO EXIT PUSH BUTTONS, INTERCOM STATIONS, NURSE CALL CANCEL STATIONS, INTRUSION DETECTION KEYPADS, WANDER PREVENTION KEYPADS, AND INFANT PROTECTION KEYPADS. REFER TO ACCESS

CONTROL SYMBOL LEGEND DESCRIPTION FOR CABLING AND ADDITIONAL REQUIREMENTS.

TYPE ‘KEYPAD’, COMBINATION KEYPAD PROXIMITY CARD READER:

PROVIDE COMBINATION KEYPAD PROXIMITY CARD READER PER SPECIFICATION.

SECURITY SURVEILLANCE

CAMERA - CEILING

GENERAL:

PROVIDE POWER, ROUGH-INS, AND CABLING FOR OWNER PROVIDED POWER OVER ETHERNET (POE) SECURITY SURVEILLANCE CAMERA AS DESCRIBED IN THESE GENERAL NOTES AND NOTES BELOW FOR EACH CAMERA TYPE AT LOCATIONS INDICATED. REFER TO FLOOR PLANS FOR CAMERA DESIGNATION. SECURITY SURVEILLANCE COMPONENTS SHALL BE RATED FOR CONTINUOUS OPERATION IN THEIR INSTALLED PROJECT CONDITIONS AS REQUIRED IN SPECIFICATIONS. PROVIDE ONE (1) CATEGORY 6A NETWORK DATA CABLE FROM ASSOCIATED COMMUNICATIONS DISTRIBUTION ROOM TO APPROXIMATE LOCATION INDICATED ON FLOOR PLANS, COILED ABOVE FINISHED CEILING. TERMINATE CABLE WITH RJ45 CONNECTOR. PROVIDE WITH 10' OF CABLE SLACK AT LOCATION INDICATED. INSTALL CAMERA CENTERED IN CEILING TILE. PROVIDE 4" SQUARE BACK BOX WITH SINGLE GANG TRIM RING AND ONE (1) 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING FOR CABLING AT LOCATIONS INDICATED WITHIN GYP CEILINGS. PROVIDE SURFACE MOUNTED CONDUIT AND BACK BOX IN UNFINISHED AREAS. COORDINATE ROUGH-IN REQUIREMENTS, PENDANT MOUNTS, PROTECTIVE DOMES, AND OTHER REQUIRED ACCESSORIES FOR EXTERIOR CAMERA LOCATIONS WITH SELECTED MANUFACTURER, AND CAMPUS SECURITY PROJECTS. PROVIDE 20A 120V NORMAL BRANCH CIRCUIT TO CAMERA LOCATIONS AS REQUIRED BY SELECTED MANUFACTURER FOR HEATED ENCLOSURES, PAN-TILT-ZOOM FUNCTIONS, AND ACCESSORIES. COORDINATE CABLING, POWER, AND ROUGH-IN REQUIREMENTS WITH SELECTED MANUFACTURER FOR CAMERA LOCATIONS WITH NETWORK DATA CABLE LENGTHS EXCEEDING 100 METERS. CABLE SHALL BE ROUTED WITHIN CABLE TRAY WHERE ABOVE ACCESSIBLE CEILINGS AND WITHIN CONDUIT IN UNFINISHED AREAS. PROVIDE NETWORK DATA CABLES AND JACKS PER SPECIFICATIONS. COORDINATE EXACT MOUNTING LOCATION WITH OWNER PRIOR TO INSTALLATION.

ELECTRICAL FIXTURE

SYMBOLS

PLAN SYMBOL NAME

JUNCTION BOX - WALL

RECEPTACLE - DOUBLE DUPLEX

- CONV

RECEPTACLE - DUPLEX - CONV

RECEPTACLE - DUPLEX - CONV -

GFCI

RECEPTACLE - DUPLEX -

EMERGENCY (RED) - CONV

RECEPTACLE - DUPLEX -

EMERGENCY (RED) - CONV -

GFCI

DATA SYMBOLS

PLAN SYMBOL NAME

FLOOR BOX - VOICE/DATA

POKE THROUGH - VOICE/DATA

ROUGH-IN COMMUNICATIONS

OUTLET - COMPUTER DATA

OUTLET

ROUGH-IN COMMUNICATIONS

OUTLET - WALL MOUNTED

TELEPHONE OUTLET

ROUGH-IN WIRELESS ACCESS

POINT - CEILING

ELECTRICAL MISC SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

CABLE TRAY PROVIDE CABLE TRAY AT LOCATIONS INDICATED ON PLANS. REFER TO FLOOR PLANS FOR TYPE DESIGNATION.

COORDINATE MOUNTING WITH OTHER TRADES AND REQUIREMENTS IN SPECIFICATION.

TYPE 'WIDTH x DEPTH", WIRE BASKET CABLE TRAY:

PROVIDE CABLE TRAY IN DIMENSION INDICATED ON FLOOR PLANS.

TYPE 'WIDTH LADDER', LADDER CABLE TRAY:

PROVIDE CABLE TRAY IN DIMENSION INDICATED ON FLOOR PLANS.

LIGHTING CONTROL TAG REFER TO LIGHTING CONTROL SCHEDULE FOR ADDITIONAL INFORMATION.

ELECTRICAL FIXTURE SYMBOL LEGEND

PLAN SYMBOL NAME DESCRIPTION

GROUND BAR PROVIDE LENGTH AS REQUIRED TO ACCOMMODATE TERMINATIONS, MINIMUM 20" IN LENGTH FOR ELECTRICAL GROUND BARS AND MINIMUM 10" IN LENGTH FOR TELECOMMUNICATIONS GROUND BARS. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

RECEPTACLE - NEMA OUTLET -

CEILING MOUNTED

PROVIDE ONE (1) 4" SQUARE, 2 1/8" DEEP JUNCTION BOX WITH 1 GANG TRIM RING. PROVIDE CONDUIT TO ELECTRICAL SOURCE SIZED AS INDICATED BELOW. REFER TO FLOOR PLANS FOR ELECTRICAL SOURCE AND NEMA

DESIGNATION. PROVIDE DEVICE, FEEDER, AND CIRCUIT BREAKER AS LISTED BELOW:

•NEMA L21-20: 4-#12, #12 GND IN 3/4" CONDUIT; 20A 3 POLE CIRCUIT BREAKER

•NEMA L21-30: 4-#10, #10 GND IN 3/4" CONDUIT; 30A, 3 POLE CIRCUIT BREAKER

LOW VOLTAGE COORDINATION LEGEND

SYSTEMS

ROUGH-INS &

PATHWAYS

CABLING &

TERMINATIONS

DEVICES &

EQUIPMENT REMARKS

ACCESS CONTROL CF / CI CF / CI CF / CI 2

FIRE ALARM CF / CI CF / CI CF / CI 3

INTRUSION DETECTION CF / CI CF / CI CF / CI

SECURITY SURVEILLANCE (CCTV) CF / CI CF / CI CF / CI 5

TELEVISION (CATV) CF / CI CF / CI OF/OI 7

TEMPERATURE MONITORING CF / CI CF / CI CF / CI 6

VOICE / DATA CF / CI CF / CI CF/CI 1

WIRELESS ACCESS POINTS CF / CI CF / CI OF/OI 1, 8

Revisions: Date:

Addendum 1 Date 1

Date 106/23/2025

F F

F

F

F

F

F

F

F

F

F

F

F

F

(1) 4" C (3) 4" C

(3) 4" C

(1) 4" C

(2) 4" C

(1) 4" C

(6) 4" C

(1) 4" C

(2) 4" C

(1) 4" C

(6) 4" C

(2) 4" C

(2) 4" C

(2) 4" C

(2) 4" C

(2) 4" C

(6) 4" C

(2) 4" C

(2) 4" C

(6) 4" C

A. THE LOCATION OF THE CONDUIT, HAND HOLES AND/OR MAINTENANCE HOLES SHOWN ARE

APPROXIMATE LOCATIONS. FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIVATE AND/OR

PUBLIC PRIOR TO THE INSTALLATION OF THE COMPONENT. FIELD COORDINATE THE FINAL

LOCATION WITH THE COR AND ENGINEER PRIOR TO INSTALLATION.

B. POTHOLING TO LOCATE EXISTING UNDERGROUND UTILITIES, SHALL BE

INCLUDED IN THE BID. CONTRACTOR IS RESPONSIBLE FOR FINAL

PLACEMENT OF HAND HOLES AND/OR MAINTENANCE HOLES AND SHALL NOTIFY THE ENGINEER AND COR

OF FINAL LOCATIONS PRIOR TO INSTALLATION.

C. HAND HOLES AND/OR MAINTENANCE HOLES SHALL BE CONSTRUCTED SO THAT THE TOP OF THE FRAME

WILL BE FLUSH WITH THE GROUND LINE.

D. REMOVAL AND REPLACEMENT OF THE EXISTING UNDERGROUND UTILITIES THAT ARE

REQUIRED TO COMPLETE THE INSTALLATION SHALL BE INCLUDED IN THE BID.

E. CONTRACTOR SHALL INCLUDE IN THEIR BID ANY REMOVAL AND REPLACEMENT OF EXISTING

SIDEWALK, PAVEMENT, GRASS, SHRUBS, TREES, ETC. THAT WILL BE IMPACTED BY THE

INSTALLATION OF THE NEW CONDUITS SHOWN ON THE DRAWINGS. IF TREES ARE REQUIRED

TO BE REMOVED THE CONTRACTOR SHALL CONTACT THE COR AND DISCUSS OPTIONS PRIOR TO CUTTING

DOWN ANY TREE OR SHRUB OVER 5' IN HEIGHT.

F. PROVIDE A MINIMUM OF 5'-0" SLACK LOOP WITHIN EACH HAND HOLES AND/OR

MAINTENANCE HOLES. SLACK LOOP SHALL BE SECURE SO FIBER IS NOT RESTING ON EARTH AFTER FINAL

INSTALLATION.

G. REFER TO TN500 FOR ADDITIONAL INFORMATION.

H. REFER TO EACH BUILDING FLOOR PLANS FOR ADDITIONAL FIBER ENTRANCE LOCATIONS AND DETAILS.

SOME ENTRANCES ARE THROUGH CRAWLSPACE TO NEW TR ROOM WITH THE ALTERNATE OPTION TO

ENTER BUILDING AT HEIGHT TO ROUTE ABOVE CEILING.

SITE PLAN GENERAL NOTES:

A. THE DUCT BANK LOOP SHALL CONSIST OF (6) 4" CONDUITS

B. (2) 4" CONDUITS SHALL CONTAIN EITHER A OR B SIDE FIBER ROUTE (LOOPED IN SEPERATE DIRECTIONS)

WITH MAXCELL 3 CELL 6 CABLE INNER DUCT OR EQUIVLENT . FIBER SHALL BE ROUTED TO THE FOLLOWING

BUILDINGS.

a. BUILDING 39

b. BUILDING 37

c. BUILDING 45

d. BUILDING 5

e. BUILDING 35

f. BUILDING 8

C. (2) 4" CONDUITS SHALL CONTAIN EITHER A OR B SIDE FIBER ROUTE (LOOPED IN SEPERATE DIRECTIONS) WITH MAXCELL 3 CELL 6 CABLE INNER DUCT OR EQUIVLENT . FIBER SHALL BE ROUTED TO THE FOLLOWING

BUILDINGS.

a. BUILDING 6

b. BUILDING 13

c. BUILDING 9

d. BUILDING 7

e. BUILDING 12

f. BUILDING 36

D. THE TWO REMAING CONDUITS SHALL BE FUTURE/SPARE. ONE SHALL CONTAIN MAXCCELL 3 CELL 6 CABLE

INNTER DUCT.

E. REFER TO CIVIL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL DETAILS.

DUCT BANK NOTES:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

7100 E BELLEVIEW AVE,

STE 107

GREENWOOD VILLAGE,

CO 80111

Phone: (720) 200-5955 www.specializedeng.com

SES Project : 22295

330 N. Mead St, Suite 100 Wichita, KS 67202

Phone: (316) 262-2500 www.hfgarchitecture.com

A u to d e s k D o c s /2

G ra n d J u n c ti o n

E H

R M

/5

-7

.B

.E

T .R

.r v t

/2

/2

:3

:4

A

M

TS001

SITE PLAN - TELECOMMUNICATIONS EHRM IU AT THE GRAND JUNCTION,

CO VA MEDICAL CENTER

2121 North Ave, Grand Junction, CO 81501

575-21-700

12/17/2024 RJA CMW

SHEET NOTES:

1. A SIDE FIBER ROUTE (PLAN SOUTH LOOP FIRST)

2. B SIDE FIBER ROUTE (PLAN NORTH LOOP FIRST)

3. BUILDING 13 SCOPE IS FOR FUTURE PATHWAY ONLY. FIBER TO BE PULLED IN FUTURE BUILDING 13 PROJECT.

CONDUIT AND PATHWAYS TO END AT FUTURE BUILDING ENTRANCE TERMINATION.

040' 40' 80'20'

1" = 40'-0"

SITE PLAN - TELECOMMUNICATIONS

N

Revisions: Date:

Room-1 1021-1

Room

2 BED

STAFF

TLT.

137A

SOILED

UTILITY

TLT.

STORAGE

100C

KITCHEN

100D

Room

TOILET

SUPPLY

CLOSET

2 BED

STORAGE

ELEC.

CLOSET.

TEL.

CLOSET

OXYGEN

CLEAN

LINEN

IT

123 TOILET

BATH

TOILET

TOILET

109A

TOILET

106A

H.A.C.

SHARED

CLO.

MED.

ROOM

BREAK

ROOM

PALLATIVE

CARE

TEAM

H.A.C 100B

STORAGE

100A

Room

Room

Room

Room

Room

Room

PRIVATE

ROOM

SINGLE

BED

FAMILY

ROOM

Room

Room-1 ....-1

2 BED

2 BED

1 BED

1 BED

CONG.

BATH

2 BED

CORR.

C-6

Room-2 ....-2

2 BED

4 BED

2 BED

2 BED

2 BED

Room

Room

Room

Room

Room

TOILET

2 BED

2 BED

Room

SINGLE

BED

Room-3 ....-3

Room

Room-4 ....-4

Room-5 ....-5

Room-1 1425-1

Room

Room

Room-6 ....-6

Room-7 ....-7

Room-8 ....-8

EXAM

ROOM

TR

ROOM

Room

Room

Room

Room

Room

Room

Room

Room 12..

Room

Room ...6

Room-1 1688-1

Room

Room

ROOM

TR

ROOM

TR

ROOM-3

1692-3

Room

Room

Room

Room

Room-1 1696-1

Room-2 1696-2

Room-3 1696-3

Room

Room

Room

Room

Room

Room

Room-1 1657-1

Room-2 1657-2

Room-1 1659-1

Room

Room

Room

Room

Room

Room

Room-2 1659-2

Room

Room

Room

DISASTER

MITIGATION

STORAGE

1612B Room

Room

Room

Room-1 1411-1

Room-2 1411-2

Room

Room

Room

Room

Room-9 ....-9

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room-1 1704-1

Room

Room

Room-10 ....-10

Room

Room

Room-1 1010-1

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room-1 1695-1

Room

Room

Room

Room

Room

Room

Room-2 1021-2

Room-3 1021-3

Room

Room 1632 Room

Room

Room

Room

Room 1701Room

Room-1 1007-1

Room-2 1007-2

Room

SOILED

HOLDING

Room-1 1001-1

Room-2 1001-2

Room-11 ....-11

Room 1637 Room

Room-3 1659-3

Room-2 1010-2

Room

Room

Room

Room-12 ....-12

Room

STAIRWELL

Room

Room-13 ....-13

Room-14 ....-14

ELECTRICAL

MECHANICAL

OFFICE

MANG.

OFFICE

PHYSICAL

THERAPY

Room

Room-1 1678-1

Room

Room-2 1678-2

Room-1 1655-1

Room-1 1697-1

MEN'S

TLT

WOMEN'S

TLT

Room-15 ....-15

Room

Room

Room

Room

VEST.

ENTRANCE

XXX

Room

Room

Room

Room-2 1695-2

Room

Room

Room

Room

Room

Room 1686A Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

MECHANICAL

ROOM

DECON

Room

Room

Room

Room

Room

Room

Room-3 1411-3

Room

Room-3 1010-3

Room-4 1010-4

Room

Room

Room

MECHANICAL

ROOM

ELECTRICAL

Room-2 1425-2

BATH

BATH

TLT.

TOILET

Room

Room-2 1697-2

Room-3 1001-3

Room 1003Room

Room 1663A

Room

Room

CORRIDOR

Room 1725 Room

Room

Room

Room

Room

Room

TR

ROOM

Room 1827Room

Room-2 1688-2

Room

Room-1 1614-1

Room-2 1614-2

Room-2 1704-2

Room

Room

Room

Room-1 1404-1

ROOM-2

1404-2

NURSE

STATION

CORR.

C-4

CORR.

C-2

SUN

ROOM

100E

DINING

Room

Room

Room

Room

Room 100.

Room

Room

Room

Room

Room

Room

Room

Room-1 1215-1

Room

Room-2 1655-2

Room

Room

Room

Room-16 ....-16

CORR.

C-3

Room-2 1215-2

Room

Room

B01-TN300

B01-TN300

A. REFER TO TECHNOLOGY DEMOLITION NOTES ON TN000.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TELECOMMUNICATIONS DEMOLITION GENERAL NOTES:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

7100 E BELLEVIEW AVE,

STE 107

GREENWOOD VILLAGE,

CO 80111

Phone: (720) 200-5955 www.specializedeng.com

SES Project : 22295

KEYPLAN N

A

B C

D B20

B C

D

330 N. Mead St, Suite 100 Wichita, KS 67202

Phone: (316) 262-2500 www.hfgarchitecture.com

A u to d e s k D o c s /2

G ra n d J u n c ti o n

E H

R M

/5

-7

.B

.E

T .R

.r v t

/2

/2

:3

:5

A

M

B01-TD101

FIRST LEVEL DEMO PLAN - OVERALL -

TELECOMMUNICATIONS

EHRM IU AT THE GRAND JUNCTION,

CO VA MEDICAL CENTER

2121 North Ave, Grand Junction, CO 81501

575-21-700

12/17/2024 RJA CMW

1" = 20'-0"

FIRST LEVEL FLOOR PLAN - OVERALL - TELECOMMUNICATION

020' 20' 40'

N

SHEET NOTES:

1. EXISTING TELECOMMUNICATIONS CLOSET LOCATION. ALL CABLING TO BE RECABLED TO NEW ROOM

SERVING AREA. EXISTING SYSTEMS THAT REMAIN SHALL BE RECABLED TO NEW TR ROOM.

Room

Room

Room-3 ....-3

Room

Room-4 ....-4

EXAM

ROOM

1687TR

ROOM

Room-1 1688-1

Room

Room-1 1696-1

Room-2 1696-2

Room-3 1696-3

Room

Room

Room

Room

Room

Room

Room-1 1657-1

Room-2 1657-2

Room-1 1659-1

Room

Room

Room

Room

Room

Room-2 1659-2

Room

Room

Room

DISASTER

MITIGATION

STORAGE

1612B

Room

Room

Room

Room-9 ....-9

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room-1 1704-1Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room-1 1695-1

Room

Room

Room

Room

Room

Room

Room-2 1021-2

Room-3 1021-3

Room

Room

Room

Room

Room

Room

Room

Room

Room

SOILED

HOLDING

Room-1 1001-1

Room-2 1001-2

Room

Room

Room-3 1659-3

Room

Room

Room

STAIRWELL

Room

Room

Room-1 1678-1

Room

Room-2 1678-2

Room-1 1655-1

Room-1 1697-1

MEN'S

TLT

WOMEN'S

TLT

Room

Room

Room

Room

Room-2 1695-2

Room

Room

Room 1686A

Room

Room

Room

Room

Room

Room

Room

Room

Room

MECHANICAL

ROOM

DECON

MECHANICAL

ROOM

ELECTRICAL

Room

Room-2 1697-2

Room-3 1001-3

Room

Room

Room 1663A

Room

Room

CORRIDOR

Room

Room

Room

Room

Room

Room

Room-2 1688-2Room

Room-1 1614-1

Room-2 1614-2

Room-2 1704-2

Room

Room

Room

Room-2 1655-2

Room

Room

Room

D-5 D-2 D-5 D-5

D-5

D-5

D-5

D-5

D-5 D-2

D-5

D-2

D-5

D-5

D-2

D-5

D-3

D-5 D-1

D-3

D-1

D-1 D-3

D-3

D-1

D-4 D-3

D-4

D-2

D-1

D-5

D-4 D-4

D-3

D-1

D-1 D-3

D-1

D-3

D-1 D-3

D-2

D-2

D-2

D-2

D-1

D-3

D-3D-3D-2

D-1

D-3

D-1 D-3

E

E

D-3 D-3 D-3 D-3

D-4D-3

D-5

D-1

D-5

D-4

D-3

D-5

D-1

D-5

D-5

E

D-5

D-5

D-3

D-3

D-3

D-3

E

D-2

D-5

D-2

D-2 D-5 D-3

D-3

D-2

D-1

E

E

E

E

D-1

D-3

D-5

D-5

D-5

D-4

D-5

D-4

D-5

D-5 D-5

D-3

D-5

D-3 D-2

D-5

D-2

D-2

D-3

D-5

D-5

D-3

D-2

D-2 D-4

D-3 D-3

D-3

D-6

D-1

D-5

D-5

D-2

D-4

D-2 D-2 D-2 D-2

D-2D-2D-2D-2

D-2 D-2 D-2 D-2

D-2D-2D-2D-2

D-2

D-2

D-2

D-2

D-2

D-5

D-1

D-2 D-2 D-2 D-5

D-5

D-5

D-3

D-3

D-3

D-3

D-5 D-1

D-5

D-3

D-3

E

D-3 D-3

D-4

D-2

D-5

D-5 D-5

D-5

D-5

D-3

D-3

D-4D-2

D-2

D-2 D-2

D-3 D-2

D-3

D-1

D-3

E

D-2 D-1

D-2

D-1

D-2

D-2D-2

D-2

D-2 D-2

E

D-2

D-2

D-2

D-2 D-5

D-2

D-2

E

D-3D-3

D-3 D-3 D-3D-3

D-3 D-3 D-4

D-1

D-5 D-5

D-3 D-5 D-3 D-4

D-6

D-5

D-2

B01-TN300

E

E

E

E

E

E

E

E

E

E E

E

E

E

EE

E

E

WAP WAP WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAPWAP

WAP

WAP

WAP

WAPWAP

WAP

WAP

WAP

1 1

A. REFER TO TECHNOLOGY DEMOLITION NOTES ON TN000.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TELECOMMUNICATIONS DEMOLITION GENERAL NOTES:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

7100 E BELLEVIEW AVE,

STE 107

GREENWOOD VILLAGE,

CO 80111

Phone: (720) 200-5955 www.specializedeng.com

SES Project : 22295

KEYPLAN N

A

B C

D

B C

D

330 N. Mead St, Suite 100 Wichita, KS 67202

Phone: (316) 262-2500 www.hfgarchitecture.com

A u to d e s k D o c s /2

G ra n d J u n c ti o n

E H

R M

/5

-7

.B

.E

T .R

.r v t

/2

/2

:3

:5

A

M

B01-TD101A

FIRST LEVEL DEMO PLAN - AREA A -

TELECOMMUNICATIONS

EHRM IU AT THE GRAND JUNCTION,

CO VA MEDICAL CENTER

2121 North Ave, Grand Junction, CO 81501

575-21-700

12/17/2024 RJA CMW

1/8" = 1'-0"

FIRST LEVEL DEMO PLAN - AREA A - TELECOMMUNICATIONS

08' 8' 16'

N

Addendum 1 Date 1Date 106/23/2025

Room

Room-1 ....-1

Room-2 ....-2

Room-5 ....-5

Room-1 1425-1

Room

Room

Room ...6

Room

Room

Room

Room

Room-1 1411-1

Room-2 1411-2

Room

Room

Room

Room

Room

Room-11 ....-11

Room

Room

Room

Room

Room

Room

Room

Room

Room-3 1411-3

Room

Room

Room

Room-2 1425-2

Room

Room-1 1404-1

ROOM-2

1404-2

Room-16 ....-16

D-3

D-3

D-4D-5D-6

D-2

D-4 D-5 D-5

D-6 D-6

D-5 D-3 D-3

D-3

D-3 D-5 D-3

D-5 D-3 D-2

D-2 D-3 D-6

D-4

D-5

D-5

D-2

D-5

D-3

D-5

D-3

D-3 D-5

D-3

D D-5

D-5

D-5

D-5

D-2

D-2 D-2 D-2

D-3D-6

E

E

E

D-3

D-3

D-5

D-2

D-5

D-5

D-5

D-5

D-3

D-3

D-5

D-3

D-3

D-2

D-2

D-2

D-5

D-5

D-2

D-5

D-1

D-5 D-2

D-2

D-5

D-3 D-3

D-3

D-3

D-5

E D-2

D-2

D-2

EE

E

E

E E

E

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAPWAP

WAP

WAP

1 1

1 1

A. REFER TO TECHNOLOGY DEMOLITION NOTES ON TN000.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TELECOMMUNICATIONS DEMOLITION GENERAL NOTES:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

7100 E BELLEVIEW AVE,

STE 107

GREENWOOD VILLAGE,

CO 80111

Phone: (720) 200-5955 www.specializedeng.com

SES Project : 22295

KEYPLAN N

A

B C

D

B C

D

330 N. Mead St, Suite 100 Wichita, KS 67202

Phone: (316) 262-2500 www.hfgarchitecture.com

A u to d e s k D o c s /2

G ra n d J u n c ti o n

E H

R M

/5

-7

.B

.E

T .R

.r v t

/2

/2

:3

:5

A

M

B01-TD101B

FIRST LEVEL DEMO PLAN - AREA B -

TELECOMMUNICATIONS

EHRM IU AT THE GRAND JUNCTION,

CO VA MEDICAL CENTER

2121 North Ave, Grand Junction, CO 81501

575-21-700

12/17/2024 RJA CMW

08' 8' 16'

N

1/8" = 1'-0"

FIRST LEVEL DEMO PLAN - AREA B - TELECOMMUNICATIONS

1021-1

Room

Room

Room 12..

Room

Room

Room

Room-1 1010-1

Room-1 1007-1

Room-2 1007-2

Room-2 1010-2

Room

Room-3 1010-3

Room-4 1010-4

Room

Room

Room

Room

Room

ROOM-2

1404-2

Room

Room

Room

Room

Room 100.

Room

Room

D-2 D-2

D-3

D-3 D-1

D-2 D-2

D-5 D-6

E

D-2

D-4

D-3 D-5 D-3 D-4

D-3

D-6

D-4

D-4

E

D-4D-4

D-4 D-4

D-5

D-3D-3

D-3D-3

D-3

D-2

E

E

E E

E

E

E

E

E

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

A. REFER TO TECHNOLOGY DEMOLITION NOTES ON TN000.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TELECOMMUNICATIONS DEMOLITION GENERAL NOTES:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

7100 E BELLEVIEW AVE,

STE 107

GREENWOOD VILLAGE,

CO 80111

Phone: (720) 200-5955 www.specializedeng.com

SES Project : 22295

KEYPLAN N

A

B C

D

B C

D

330 N. Mead St, Suite 100 Wichita, KS 67202

Phone: (316) 262-2500 www.hfgarchitecture.com

A u to d e s k D o c s /2

G ra n d J u n c ti o n

E H

R M

/5

-7

.B

.E

T .R

.r v t

/2

/2

:3

:5

A

M

B01-TD101C

FIRST LEVEL DEMO PLAN - AREA C -

TELECOMMUNICATIONS

EHRM IU AT THE GRAND JUNCTION,

CO VA MEDICAL CENTER

2121 North Ave, Grand Junction, CO 81501

575-21-700

12/17/2024 RJA CMW

1/8" = 1'-0"

FIRST LEVEL DEMO PLAN - AREA C - TELECOMMUNICATIONS

08' 8' 16'

N

Room

Room

Room

Room

Room

Room

Room

Room-6 ....-6

Room-7 ....-7

Room-8 ....-8

Room

Room

Room

Room

Room

Room

Room

Room 12..

Room

Room

Room

Room-10 ....-10

Room

Room

Room

Room-12 ....-12

Room-13 ....-13

Room-14 ....-14

Room-15 ....-15

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room-1 1215-1

Room

Room-2 1215-2

D-3D-6

D-3

D-1

D-1

D-3

D-1

D-3

D-5

D-1

E

E

E

E

D-1

E

E

E

E

E

E

E

E

E

E E

E

E

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAPWAP

A. REFER TO TECHNOLOGY DEMOLITION NOTES ON TN000.

(GENERAL NOTES SHALL APPLY TO ALL SHEETS)

TELECOMMUNICATIONS DEMOLITION GENERAL NOTES:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

7100 E BELLEVIEW AVE,

STE 107

GREENWOOD VILLAGE,

CO 80111

Phone: (720) 200-5955 www.specializedeng.com

SES Project : 22295

KEYPLAN N

A

B C

D

B C

D

330 N. Mead St, Suite 100 Wichita, KS 67202

Phone: (316) 262-2500 www.hfgarchitecture.com

A u to d e s k D o c s /2

G ra n d J u n c ti o n

E H

R M

/5

-7

.B

.E

T .R

.r v t

/2

/2

:3

:5

A

M

B01-TD101D

FIRST LEVEL DEMO PLAN - AREA D -

TELECOMMUNICATIONS

EHRM IU AT THE GRAND JUNCTION,

CO VA MEDICAL CENTER

2121 North Ave, Grand Junction, CO 81501

575-21-700

12/17/2024 RJA CMW

1/8" = 1'-0"

FIRST LEVEL DEMO PLAN - AREA D - TELECOMMUNICATIONS

08' 8' 16'

N

Revisions: Date:

Addendum 1 Date 1

2016-1

Room

Room

TR

ROOM

Room

Room

Room

Room

Room

Room

Room 2681 Room

Room

Room

Room

Room

Room-1 2023-1

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room-1 2646-1

Room-2 2646-2

Room-3 2646-3

Room-4 2646-4

Room

Room

Room-1 2411-1

Room

Room-17 ....-17

Room-1 2215-1

Room

Room

Room-18 ....-18

Room

Room-1 2407-1

Room-2 2407-2

Room

Room

Room

Room-19 ....-19

Room

Room-1 2657-1

Room-2 2657-2

Room-3 2657-3

Room-4 2657-4

Room

Room

Room

Room

Room

Room-1 2610-1

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room-1 2010-1

Room

Room-1 2013-1

Room-2 2010-2

Room

Room

Room

Room

Room

Room 2608Room

Room

Room-20 ....-20

Room-21 ....-21

Room-1 2708-1

Room-2 2708-2

Room

Room

Room

Room

Room

Room

Room-2 2610-2

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room-1 2672-1

Room-2 2672-2

Room-1 2675-1

Room-2 2675-2

Room-1 2669-1

Room-2 2669-2

Room

Room

Room-2 2411-2

VV

Room

Room

Room

Room

Room

Room

Room

Room 22..

Room

Room

ROOM

Room-3 2610-3

Room

Room

Room

Room-1 2201-1

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room

Room-22 ....-22

Room-23 ...

This is the start of the file's text. The full file is on GovTribe.