This document is a detailed technical drawing for an ADA Warning Panel (Detectable Warning Surface) by ADA Solutions, Inc., specifically a 24" x 60" Sound Attenuating Embedment Panel Detectable Warning Surface System for a curb ramp tile with an inline dome design. The technical drawing (dated 7 Feb 2016, drawing number FA4861-16-R-A300) provides comprehensive dimensional specifications including multiple detailed views labeled "Detail A", "Detail B", and "Detail C" that illustrate the panel's precise geometric configuration, embedment flanges, hole placements, and structural characteristics. The drawing includes precise measurements for panel thickness, hole diameters, spacing, and orientation, with internal embedment flanges positioned at 6" center-to-center intervals and 0.625" diameter orientation holes. The panel appears designed for installation in compliance with ADA accessibility requirements, featuring a grid of raised tactile domes to provide visual and tactile warning for pedestrians at potential hazard transitions like curb ramps.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DETAIL "A"
DETAIL "B"
DIA.
DIA.
DETAIL "C"
AS SHOWN IN PLAN
EMBEDMENT FLANGES
0.625" DIA. HOLE
FOR ORIENTATION)
FLANGE @ 6" C/C (SEE PLAN
INTERNAL EMBEDMENT
PART O.A.
DETAIL "C"
DETAIL "B"
DETAIL "A"
PART O.A.
FLANGE @ 6" C/C
INTERNAL EMBEDMENT
0.625" DIA. HOLE
EMBEDMENT FLANGES
TOP OF PANEL BOTTOM OF PANEL
2.
1.
-9
E Q
UA
L
SP
AC
ES
1.200 2.3500
.500
.900
.1875
1.
.1
3.750
6.000
5 EQUAL SPACES .750
.2
.1875
.0
.0
.0
90°
.0600
DIA. .09000
DIA.
90°
60.000
.0
.6
1.
1.
- E
Q
UA
L
SP
AC
ES
PA
RT
O .A
60.000
PA
RT
O .A
.0
DRAWING NO. REV. NO.
DETECTABLE WARNING SURFACE
PROJECT
SCALE
TRADE
MATERIAL
PART NO.
CURB RAMP TILE (INLINE DOME)
PLANS AND DETAILS
SEE MATERIAL LIST
24" x 60" SOUND ATTENUATING
EMBEDMENT PANEL DETECTABLE
WARNING SURFACE SYSTEM
DETECTABLE WARNING SURFACE
AS NOTED
FULL SIZE
DESCRIPTIONITEM
PART NO.
MATERIAL LIST
QT'Y
ADA SOLUTIONS, INC.
P.O. Box 3 N.Billerica, Ma. 01862
Appendix 15 ADA Warning Panel Detail 7 Feb 2016 FA4861-16-R-A300