Addendum 3_ODF Santiam Fire and Admin_DOJ approved.pdf
PDF 2 MB Posted
- Solicitation number
- S-DASOBO-00015003
- Issued by
- Lake County, Oregon
About this file
This Solicitation Addendum No. 3, issued by the Oregon Department of Forestry (ODF) for the ODF Santiam Fire & Admin Buildings Construction project (S-DASOBO-00015003/S-DASOBO-00015004), modifies the original bidding documents dated October 15, 2025. The addendum, approved by the Department of Justice on February 3, 2026, and dated February 2, 2026, modifies Attachment C (Plans and Drawings) in the Plans_ODF Permit Set. Specific revisions include modifications to civil plan C103 (addition of a 2" backflow preventor, revised oil/water separator connection to the septic system, revised keynotes, and revised septic tank connections), wastewater treatment system plan W003 (revised septic connections), and plan W004 (revised septic connections). Protests to this addendum must be submitted by February 6, 2026, at 5:00 PM PT using the same procedures outlined in RFP Section 4.4. Acknowledgement of Addendum No. 3 with authorized representative signature and date is required prior to bid closing; failure to acknowledge may result in bid rejection.
The architectural plans provided show utility and site layout details for the North Cascade District Headquarters facility located at 22965 North Fork Road SE, Lyons, Oregon, designed by LRS Architects, Inc. (Project No. 223294) with on-site wastewater treatment design by Fuhriman Septic Design & Consulting. The site plans detail water infrastructure including a new 2" water meter, 6" fire service line, 2.5" domestic water service line, fire hydrant installation, backflow preventor installation with freeze-protection heating, and a 2" waterline reconnection to the existing seedling building. Sewer improvements include a new oil/water separator, 4" PVC sewer line construction, an Orenco AX20 2-pod mode 3B wastewater treatment system, and piping to the drainfield. The plans also address utility coordination requirements including contractor notification to "One Call" for utility locates and potholing of existing utilities prior to excavation. The site encompasses three parking lots (public, staff, and fleet), the proposed 4,251 square foot fire shop building, the proposed 6,825 square foot office building, and existing structures to be retained or decommissioned per Marion County requirements.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INVITATION TO BID
S-DASOBO-00015003
SOLICITATION ADDENDUM #3
ODF Santiam Fire & Admin Buildings S-DASOBO-00015004 ADDENDUM #3 Page 1 of 1
This Solicitation Addendum modifies the Bid Document(s) only to the extent indicated herein. All other areas not specifically mentioned or affected by this Solicitation Addendum shall remain in full force. This Solicitation Addendum shall be added as a part of the Original Bidding Documents.
This Solicitation Addendum must be acknowledged by providing the required signature prior to Bid Closing. Failure to do so may result in rejection of Bid.
1 Modification Attachment C – Plans and Drawings (Plans_ODF Permit Set) is modified per Addendum 3 Attachment 1 attached hereto.
PROTEST
Protests to this addendum must be submitted in the same manner required in RFP Section 4.4 – Solicitation Protests and are due by February 6, 2026 at 5:00PM PT.
DOJ APPROVAL
DOJ approval by: Maribeth Bonner, Assistant Attorney General - via email February 3, 2026
Acknowledgement of Addendum #3
Bidder Name: Company Name:
Authorized Representative Signature & Date
END OF ADDENDA #3
ADDENDUM TO CONTRACT DOCUMENTS
Project: ODF NCD Santiam Facility Owner: Oregon Department of Forestry North Cascade District Headquarters Building F, 200 State Street 22965 North Form Road SE Salem, Oregon 97310 Lyons, Oregon 97358
To: Bidders Architect: LRS Architects, Inc.
720 NW Davis Street, Suite 300 Portland, OR 97209
Project No. 223294
Date: February 2, 2026 Addendum No: 03
This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated October 15, 2025.
Att C – Plans ODF Permit Set
Civil
C103
1. Added 2” backflow preventor
2. Revised Oil/Water separator to provide a connection to the septic system
3. Revised keynotes
4. Revised septic tank connections
On-Site Wastewater treatment system
W003
1. Revised septic connections
W004
1. Revised septic connections
ATTACHMENTS
Drawings:
C103 W003 W004
END OF ADDENDUM NO. 03
NO
RT
H
SA
NT
IA
M H
IG
HW
AY
NORTH FORK ROAD
E
GA
TE
12" SD
24" SD
EXISTING
SEEDLING
BLDG
FF = 688.6
MB
FIRE SHOP BUILDING
4,251 SF
OFFICE BUILDING
6,825 SF
T
TT
47 5044
JOIN EXISTING
INV 684.70
IN
V
3.8
INV 685.50
INV 683.15
SEPTIC TANKS
DESIGN BY OTHERS
S=0.
S= 0.0
IN
V
4.7
IN
V
3.2
S=0.025
4" SS
PIPING TO DRAINFIELD
PER SEPTIC DESIGN
4" SS
4"
SS
4" SS
S=0.010 4" SS
10" SD
12" SD
8" SD
12" SD
12" SD
12" SD
12" SD
E NG I NE ERREG
ISTERED PROFESSIONAL
103436PE
OREGONK E R R Y S E S S I O N S
EXPIRATION DATE: 06/30/2026
SEPT . 12 , 2023
D
AT
E:
2/
2/
F
IL
E:
w
:\2 m is c pr iv at e en gi ne er in g w or k\
-3 lr s ar ch ite ct s
- o df n cd s an tia m fa ci lit y\ d es ig n se rv ic es \C
AD
\D
W G
\L ay ou ts
\O D
F C
D C iv il\
O D
F C
D C iv il.
dw g
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 www.lrsarchitects.com Portland OR 97209
AR CHI TE C TS
720 NW Davis 503.221.1121
Bid Set
ODF NCD
Santiam Facility
North Cascade District Headquarters 22965 North Fork Road
SE
Lyon, OR 97358
223294
LRS Architects, Inc. © 2024
WILLAMETTE VALLEY
541.223.5130 WWW.CIVILWEST.COM
1 ADDENDUM 01 1/9/2026
IJB
C103 2/2/2025
UTILITY PLAN
WATER CONSTRUCTION NOTES:
JOIN EXISTING 6" PVC WATER
INSTALL NEW FIRE HYDRANT
CONSTRUCT 6" HYDRANT LATERAL AND VALVE.
CONNECT TO EXISTING 6" PVC PIPE.
NEW 2" WATER METER TO BE INSTALLED BY
LYONS-MEHAMA WATER DISTRICT
CONSTRUCT 6" PVC FIRE SERVICE LINE
CONSTRUCT 2.5" PVC DOMESTIC WATER
SERVICE LINE
INSTALL 6" WATTS SERIES 757 DOUBLE
DETECTOR CHECK ASSEMBLY (OR OWNER
APPROVED EQUIVALENT) IN UNDERGROUND
VAULT
INSTALL FIRE DEPARTMENT CONNECTION
INSTALL WATTS LF009M2-QT 2 (2") BACKFLOW
PREVENTOR IN WATTS WPHR-2-G INSULATED
ENCLOSURE (OR OWNER APPROVED
EQUIVALENT) INSTALLED ON A CONCRETE PAD.
PROVIDE ELECTRICAL SERVICE FOR
FREEZE-PROTECTION HEATING.
INSTALL TOP FILL STATION
INSTALL IRRIGATION BACKFLOW PREVENTER
PER LANDSCAPE PLAN
CONSTRUCT 2" PVC WATERLINE TO RECONNECT
WATER TO SEEDLING BUILDING
NOTE:
THIS PLAN DOES NOT
SHOW THE PROPOSED
SEPTIC DESIGN FOR THE
PROJECT THAT WILL BE
DESIGNED BY OTHERS.
N
PLAN SCALE
1"=20'
020 20 40
MISC. UTILITY NOTES:
UNDERGROUND POWER TO BE INSTALLED BY
CONSUMER POWER INC
NEW TRANSFORMER PER ELECTRICAL SHEETS
NEW OIL/WATER SEPARATOR. SEE PLUMBING
SHEETS.
CONNECT ENTRY GRATE DRAIN TO BUILDING
SANITARY PIPING PER PLUMBING SHEETS
UNDERGROUND REFRIGERANT PIPING PER
MECHANICAL SHEETS
CONSTRUCT 4" PVC SEWER LINE
SHEET NOTES:
1. CONTRACTOR SHALL CONTACT "ONE CALL" FOR UTILITY
LOCATES PRIOR TO THE START OF ANY EXCAVATION.
2. CONTRACTOR SHALL POTHOLE ALL EXISTING UTILITIES
PRIOR TO COMMENCING CONSTRUCTION. IF THE
LOCATION OR CONNECTIONS OF UNDERGROUND
UTILITIES DIFFER FROM THOSE SHOWN ON THE PLANS,
OR IF UNMARKED UTILITIES ARE DISCOVERED, THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE PROJECT
ENGINEER.
3 ADDENDUM 03 2/02/2026
T
EX. RET WALL
G
AT
E
NORTH FORK ROAD
N O
R
TH
S
AN
TI
AM
H
IG
H W
AY
EXISTING
SEEDLING BLDG
EXISTING
STATE FOREST
BUILDING
PARKING
LOT 01
(PUBLIC
PARKING)
PARKING LOT 02
(STAFF PARKING)
PARKING LOT 03
(FLEET PARKING)
PROPOSED FIRE SHOP
BUILDING
4,251 SF
PROPOSED OFFICE
BUILDING
6,825 SF
TBM 100'
GROUND AT GAS METER
R
R
R
SEASONAL DRAINAGE
35'
35'
10' 14' 10' 10'
15'
10' 10' 10' 14' 11'
DRAINFILED TO SERVE
EXISTING BUILDING
2" SCH 40 PVC IN 4"
ABS OR SCH 40 PVC SLEEVE
MANIFOLD
(SEE DETAIL PG. 8)
24" TALL BERM TO DIVERT
SURFACE WATER AWAY
FROM DRAIFIELD AND
TOWARD DRAINAGE
SUGGEST CONTROL
PANEL LOCATION
EXISTING SEPTIC TANKS
TO BE DECOMMISSIONED
PER MARION COUNTY
REQUIREMENTS
28'
ST1RT1
DT1
ORENCO AX20
2 POD MODE 3B10
2.5" WATER LINE
6" FIRE SERVICE LINE
2" SCH 40 PVC IN 4"
ABS OR SCH 40 PVC SLEEVE
SEWER LINE FIRE SHOP
SEWER LINE OFFICE
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
PRELIMINARY
NOT FOR
CONSTRUCTION
Suite 300 www.lrsarchitects.com
Portland OR 97209
A R C H I T E C T S 720 NW Davis 503.221.1121
Author
W003
SITE PLAN
Bid Set
ODF NCD
Santiam Facility
North Cascade District Headquarters 22965 North Fork Road
SE
Lyon, OR 97358
223294
10/25/2025
LRS Architects, Inc. © 2024
FUHRIMAN SEPTIC
DESIGN & CONSULTING
(435)760-0717 tyler@fuhrimanconsulting.com www.fuhrimanconsluting.com
Tyler Fuhriman
EH-W-10199358
Expires:5/31/2026
SRETA
W E
T S
A W
T S
I L
A
ICEP
N
OGEROFO
ETA
T
S
N
0 20 40
1" = 40'
If this bar does not measure 1" then plan is not to scale
R
R
R
SEASONAL DRAINAGE
35'
35'
10' 14' 10' 10'
15'
10' 10' 10' 14' 11'
MANIFOLD
(SEE DETAIL PG. 8)
24" TALL BERM TO DIVERT
SURFACE WATER AWAY
FROM DRAIFIELD AND
TOWARD DRAINAGE
28'
2" SCH 40 PVC IN 4"
ABS OR SCH 40 PVC SLEEVE
T
PARKING
LOT 01
(PUBLIC
PARKING)
PARKING LOT 02
(STAFF PARKING)
PARKING LOT 03
(FLEET PARKING)
PROPOSED FIRE SHOP
BUILDING
4,251 SF
PROPOSED OFFICE
BUILDING
6,825 SF
2" SCH 40 PVC IN 4"
ABS OR SCH 40 PVC SLEEVE
SUGGEST CONTROL
PANEL LOCATION
EXISTING SEPTIC TANKS
TO BE DECOMMISSIONED
PER MARION COUNTY
REQUIREMENTS
ST1RT1
DT1
ORENCO AX20
2 POD MODE 3B10
2.5" WATER LINE
6" FIRE SERVICE LINE
SEWER LINE FIRE SHOP
SEWER LINE OFFICE
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
PRELIMINARY
NOT FOR
CONSTRUCTION
Suite 300 www.lrsarchitects.com
Portland OR 97209
A R C H I T E C T S 720 NW Davis 503.221.1121
Author
W004
DETAILED SITE
PLAN
Bid Set
ODF NCD
Santiam Facility
North Cascade District Headquarters 22965 North Fork Road
SE
Lyon, OR 97358
223294
10/25/2025
LRS Architects, Inc. © 2024
FUHRIMAN SEPTIC
DESIGN & CONSULTING
(435)760-0717 tyler@fuhrimanconsulting.com www.fuhrimanconsluting.com
Tyler Fuhriman
EH-W-10199358
Expires:5/31/2026
SRETA
W E
T S
A W
T S
I L
A
ICEP
N
OGEROFO
ETA
T
S
N
0 10 20
1" = 20'
If this bar does not measure 1" then plan is not to scale
File details come from the government source that posted it. Updated .