The specification covers room/door signs, interior directional/informational signs, emergency evacuation maps, building identification signs, plaques, and traffic signs. All signage must comply with ADA Standards and ICC A117.1 accessibility requirements. Key technical requirements include: tactile signage with letters raised minimum 1/32 inch and Grade II braille, flat signs with engraved panel media, internal illuminated double-sided light box for exterior building identification, and dimensional aluminum letters with 1/8 inch minimum thickness. Signs must be bilingual with text approved by the Tribal Steering Committee. Approved manufacturers include Best Sign Systems, Vista System, and A.R.K. Ramos Architectural Signage Systems. The specification requires manufacturer qualifications of minimum three years experience and detailed submittal requirements including product data, samples, and signage schedules. Installation must follow manufacturer instructions with signs mounted at heights complying with ADA Standards.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H IH PUEB 21100 Pueblo Pintado Health Center - FINAL CONSTRUCTION DOCUMENTS REV. - 10/20/2023
HFG Architecture © 2022
SIGNAGE
10 14 00 - 1
SECTION 10 14 00
SIGNAGE
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Room and door signs.
B. Interior directional and informational signs.
C. Emergency evacuation maps.
D. Building identification signs.
E. Plaque.
F. Traffic signs.
1.02 RELATED REQUIREMENTS
A. Section 26 51 00 - Interior Lighting: Exit signs required by code.
1.03 PRICE AND PAYMENT PROCEDURES
A. Room and door signs are not covered by the allowance.
1.04 REFERENCE STANDARDS
A. 36 CFR 1191 - Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and
Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines; current edition.
B. ADA Standards - Americans with Disabilities Act (ADA) Standards for Accessible Design; 2010.
C. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2017.
D. NFPA 170 - Standard for Fire Safety and Emergency Symbols; 2018.
E. UL 1994 - Luminous Egress Path Marking Systems; Current Edition, Including All Revisions.
1.05 SUBMITTALS
A. See Section 01 30 00 - Administrative Requirements, for submittal procedures.
B. Product Data: Manufacturer's printed product literature for each type of sign, indicating sign styles, font, foreground and background colors, locations, overall dimensions of each sign.
C. Signage Schedule: Provide information sufficient to completely define each sign for fabrication, including room number, room name, other text to be applied, sign and letter sizes, fonts, and colors.
1. When room numbers to appear on signs differ from those on drawings, include the drawing room number on schedule.
2. Submittal shall include bi-lingual text which will be reviewed and approved by the Tribal
Steering Committee or representative.
3. Submit for approval by Owner through Architect prior to fabrication.
D. Samples: Submit one sampleof Architect's chosen sign type, of size similar to that required for project, illustrating sign style, font, and method of attachment.
E. Selection Samples: Where colors are not specified, submit color selection charts or chips.
F. Verification Samples: Submit samples showing colors specified.
G. Manufacturer's Installation Instructions: Include installation templates and attachment devices.
H. Manufacturer's Qualification Statement.
1.06 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with minimum three years of documented experience.
PUEBLO PINTADO HEALTH CENTER FINAL CONSTR. DOCS.
HFG Architecture © 2022
SIGNAGE
10 14 00 - 2
1.07 DELIVERY, STORAGE, AND HANDLING
A. Package signs as required to prevent damage before installation.
B. Package room and door signs in sequential order of installation, labeled by floor or building.
C. Store tape adhesive at normal room temperature.
1.08 FIELD CONDITIONS
A. Do not install tape adhesive when ambient temperature is lower than recommended by manufacturer.
B. Maintain this minimum temperature during and after installation of signs.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Flat Signs:
1. Best Sign Systems, Inc; ____: www.bestsigns.com/#sle.
2. Vista System,www.vistasystem.com/#sle.
3. Substitutions: See Section 01 60 00 - Product Requirements.
B. Dimensional Letter Signs:
1. A.R.K. Ramos Architectural Signage Systems; Cast Aluminum Letters:
www.arkramos.com/#sle.
2. Substitutions: See Section 01 60 00 - Product Requirements.
C. Other Signs - Exterior Light Box :
1. Vista System. www.vistasystem.com/#sle
2. Substitutions: See Section 01 60 00 - Product Requirements.
D. Plaques:
1. Substitutions: See Section 01 60 00 - Product Requirements.
2.02 SIGNAGE APPLICATIONS
A. Accessibility Compliance: Signs are required to comply with ADA Standards and ICC A117.1, unless otherwise indicated; in the event of conflicting requirements, comply with the most comprehensive and specific requirements.
B. Room and Door Signs: Provide a sign for every doorway, whether it has a door or not, not including corridors, lobbies, and similar open areas.
C. General Signage Requirements
1. Sign Type: Flat signs with engraved panel media as specified.
2. Provide "tactile" signage, with letters raised minimum 1/32 inch and Grade II braille.
3. Character Height: As specified on the drawings.
4. Rest Rooms: Identify with pictograms, the names "MEN" and "WOMEN", room numbers to be determined later, and braille.
D. Interior Directional and Informational Signs:
1. Sign Type: Same as room and door signs.
2. Sizes: As indicated on drawings.
E. Emergency Evacuation Maps:
1. Map content to be provided by Owner.
2. Dimensions and Locations of Signs: As indicated on drawings.
F. Exterior Building Identification Signs:
1. Internal Luminated Double sided light box
2. Color: Color as Selected
HFG Architecture © 2022
SIGNAGE
10 14 00 - 3
G. Other Dimensional Letter Signs:
1. Exterior: Size as indicated on drawings, non-illuminated aluminum
2. Interior: Size and finish as indicated on drawings.
H. Traffic Signs: To match campus standards; locate where indicated on drawings.
2.03 SIGN TYPES
A. Flat Signs: Signage media without frame.
1. Edges: Square.
2. Corners: Square.
3. Frame Finish: TBD.
4. Clear Cover: For customer produced sign media, provide clear cover of polycarbonate plastic, glossy on back, non-glare on front.
5. Wall Mounting of One-Sided Signs: Tape adhesive.
B. Color and Font: Unless otherwise indicated:
1. Character Font: Helvetica, Arial, or other sans serif font.
2. Character Case: Upper case only.
3. Background Color: Clear.
4. Character Color: Contrasting color.
2.04 DIMENSIONAL LETTERS
A. Metal Letters:
1. Metal: Aluminum casting.
2. Metal Thickness: 1/8 inch minimum.
3. Letter Height: As indicated on drawings.
4. Text and Typeface:
a. Character Font: Helvetica, Arial, or other sans serif font.
b. Character Case: Upper case only.
5. Finish: Brushed, satin.
6. Mounting: Pin Mounted
2.05 ACCESSORIES
A. Concealed Screws: Stainless steel, galvanized steel, chrome plated, or other non-corroding metal.
B. Exposed Screws: Chrome plated.
C. Tape Adhesive: Double sided tape, permanent adhesive.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that substrate surfaces are ready to receive work.
3.02 INSTALLATION
A. Install in accordance with manufacturer's instructions.
B. Install neatly, with horizontal edges level.
C. Locate signs and mount at heights indicated on drawings and in accordance with ADA
Standards and ICC A117.1.
D. Protect from damage until Date of Substantial Completion; repair or replace damaged items.
END OF SECTION 10 14 00