This is a NESHAP Asbestos Survey Report prepared for the Federal Aviation Administration's Mike Monroney Aeronautical Center (MMAC) facility located at 6620 South Duke Avenue, Oklahoma City, Oklahoma 73159. The survey was conducted on December 16, 2025, by Leidos Corporation under the National Airspace System (NAS) Integration Support Contract (NISC) IV, with field work performed by certified asbestos inspector J. Hunter Henrie (Oklahoma Asbestos Inspector #401011). The inspection included a review of historical documents, visual inspection, and bulk sampling of suspect building materials to identify the presence, type, condition, and percentage of asbestos-containing building materials (ACBM).
The 1,821-square-foot building was constructed in 1992 with steel framework on concrete foundation, metal exterior siding, and metal roof, containing an office, small laboratory, and wastewater treatment area. During the inspection, 25 samples from 11 homogeneous areas were collected and analyzed using Polarized Light Microscopy (PLM) methodology by Pace Analytical and Green Country Testing laboratories. All samples tested negative for asbestos fibers with a reporting limit of 0.10 percent. The survey concluded that no building materials were identified as asbestos-containing via laboratory analysis or presumed to contain asbestos. The report includes appendices containing certifications of the qualified asbestos inspector, photographic documentation of the building exterior, detailed analytical results, and a sample location map with all negative sample identifications marked.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NESHAP Asbestos Survey Mike Monroney Aeronautical Center (MMAC)
186-IWT Industrial Water Treatment Plant 6620 South Duke Avenue, Oklahoma City, Oklahoma 73159
Prepared For:
Federal Aviation Administration Mike Monroney Aeronautical Center
Environmental, Occupational, Safety and Health AMP100
December 24, 2025
Prepared By:
Leidos Corporation
NISC IV
6128 S.W. 68th Street, BMB Rm. 145
(405) 954-1185
Prepared By:
J. Hunter Henrie
Oklahoma Asbestos Inspector #401011
NESHAP Asbestos Survey Report Mike Monroney Aeronautical Center 186-IWT Industrial Water Treatment Plant
Introduction
At the request of the Mike Monroney Aeronautical Center (MMAC), Environmental Occupational Safety and Health department Leidos National Airspace System (NAS) Integration Support Contract (NISC) personnel conducted an Asbestos Survey on 12-16-25 at the Building # 186-IWT located at 6620 South Duke Avenue, Oklahoma City, Oklahoma 73159.
The initial field work was performed on December 16, 2025, by Leidos asbestos inspector J.
Hunter Henrie (Oklahoma Asbestos Inspector # 401011).
This Asbestos Inspection included a review of any historical documents available, a visual inspection, and bulk sampling (if necessary) of suspect building materials to determine the presence, type, condition, and percentage of asbestos containing building materials (ACBM).
The review of historical data included Google Earth™, Aerial photos of MMAC site, Archibus® and information provided by the Federal Aviation Administration (FAA) organization representative.
Facility Description
The building encompasses approximately 1,821 square feet (SF) and, according to Archibus®, was constructed in 1992. It is supported by a steel framework on a concrete foundation, with a metal exterior siding and a metal roof. The interior layout includes a single office, a small laboratory, and a wastewater treatment area which encompasses roughly half of the total building space.
Results & Recommendations
During the onsite visual and physical inspection of the structure, 25 samples from 11 homogeneous areas were identified and sampled. All the samples tested negative for asbestos fibers.
Subsequently, no building materials were identified as asbestos containing via laboratory analysis or are assumed to contain asbestos.
Appendix A
Certifications
Appendix B
Photographic Log
PHOTOGRAPHIC LOG: 186-IWT – Industrial Water Treatment Plant
West view of the building. (Photograph taken facing towards the east)
South view of the building. (Photograph taken facing towards the north)
East view of the building. (Photograph taken facing towards the west)
Appendix C
Analytical Results
Date Received: 12/17/2025
Project: Omega COCID 3101
Pace Set ID 500148
Analyzed By: Tanner Smith
Methodology: EPA/600/R-93/116
Polarized Light Microscopy Asbestos Analysis Report
Project Location: N/A
Project Number: 2512277
Account Number: 69-000076
Received By: Baylie Puga
Date Analyzed: 12/23/2025
Pace
Sample ID
Client
Sample ID Composition
Color /
Description Asbestos (%)
Non-Asbestos
Fiber (%)
Client: Green Country Testing
6825 E. 38th St.
Tulsa, OK 74145
Non Fibrous
001 2512277-001A Homogeneous Glue
Paint
Asbestos Not Present NA
Caulk
Gray
002 2512277-002A Homogeneous GlueAsbestos Not Present NA
Caulk
Clear
003 2512277-003A Homogeneous Glue
Paint
Asbestos Not Present NA
Caulk
Gray
Date of Report
12/26/2025
Tanner Smith, Laboratory Analyst
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis. Pace Analytical is a NVLAP accredited Testing PLM laboratory (Lab Code:
101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA—40 CFR Appendix E to Subpart E of Part 763, Interim Method of the Determination of Asbestos in Bulk Insulation Samples; and EPA/600/R-93/116: Method for the Determination of Asbestos in Bulk
Building Materials. This report may not be used to claim product endorsement by NVLAP or any agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory. If submitted samples are inhomogeneous in nature, then subsamples of the components will be analyzed separately. Samples determined to contain asbestos fibers, will have the following acceptable error ranges (1% = 0-3%, 5% = 1-9%, 10% = 5-15%, 20% = 10-30%, 50%
= 40-60%, etc.) as specified per EPA Method 600/R-93/116, Table 2-1.
December 29, 2025
Federal Aviation Administration
Vicki Ray
Dear Vicki Ray:
RE: 190-CLS
Order No.: 2512277
FAX
TEL:
6500 S MacArthur Blvd, MAP-100A
Oklahoma City, OK 73169
Green Country Testing, Inc.
6825 E 38th Street
Tulsa, OK 74145
Website: www.greencountrytesting.com
TEL: 918-828-9977 FAX: 918-828-7756
Susie Southwell
In accordance with your instructions, Green Country Testing conducted the analysis shown on the following pages on samples submitted by your company. The results relate only to the items tested. Unless otherwise noted, all analysis were conducted using EPA approved methodologies. Test reports meet all the NELAC requirements. All relevant sampling information is on the attached chain-of-custody form. The initials SUB as the analyst designate any testing sub-contracted by Green Country Testing.
Certifications/Accreditation: OK - 9953 ; 7604
A scope of Certified/Accredited parameters is available upon request. If you have any questions regarding these tests results, please feel free to call.
Sincerely, Green Country Testing, Inc. received 3 sample(s) on 12/16/2025 for the analyses presented in the following report.
Original
Project: 190-CLS
CLIENT: Federal Aviation Administration Lab Order: 2512277
12/29/2025
Analytical Report
2512277
Date Reported:
WO#:
(continuous)
Green Country Testing, Inc.
6825 E 38th Street
Tulsa, OK 74145
Website: www.greencountrytesting.com
TEL: 918-828-9977 FAX: 918-828-7756
Client Sample ID: 190-1216-CLK-01A Exterior Caulking-Louver Vent-E.Si
Lab ID: 2512277-001 Collection Date: 12/16/2025
Matrix: MISCELLANEOUS SOLID MA
Analyses Result Qual Units Date AnalyzedDFRL
ASBESTOS - N PLM Analyst: 8727
Asbestos 12/23/20250.10 % 1Asbestos Not Present
Client Sample ID: 190-1216-CLK-01B Exterior Caulking-Waste water pipe
Lab ID: 2512277-002 Collection Date: 12/16/2025
Matrix: MISCELLANEOUS SOLID MA
Analyses Result Qual Units Date AnalyzedDFRL
ASBESTOS - N PLM Analyst: 8727
Asbestos 12/23/20250.10 % 1Asbestos Not Present
Client Sample ID: 190-1216-CLK-01C Exterior Caulking-West Entrance D
Lab ID: 2512277-003 Collection Date: 12/16/2025
Matrix: MISCELLANEOUS SOLID MA
Analyses Result Qual Units Date AnalyzedDFRL
ASBESTOS - N PLM Analyst: 8727
Asbestos 12/23/20250.10 % 1Asbestos Not Present
Qualifiers:
Original
H Holding times for preparation or analysis exceeded M Manual Integration used to determine area response
ND Not Detected at the Reporting Limit PL Permit Limit
RL Reporting Detection Limit W Sample container temperature is out of limit as specified at testcode
Appendix D
ACM & Sample Location Map
Building 186-IWT Industrial Water Treatment Plant Known ACM Locations (None Identified)
*No asbestos containing materials were identified during the inspection.
= Positive Sample ID (No Positive Samples Present)
= Negative Sample ID
186-1216-XXXX-00A
186-1216-XXXX-00A
Sample Collection Date: 12/16/25 Green Country Testing Lab Order #: 2512277 All samples collected were non-detect
001-MMDD-MAT-00A
Building Number Identifier Month and Day of Collection
Building Material Description Identifier Homogeneous Area Number Identifier
Sample Identifier
186-1216-DWGB-01A
186-1216-DWGB-01B
186-1216-DWJC-02A
186-1216-DWJC-02B
186-1216-FT-06A
186-1216-FTM-07A
186-1216-CB-04B
186-1216-CBM-05B
186-1216-SAT-03A
186-1216-SAT-03B
186-1216-DM-10A
186-1216-DM-10B
186-1216-CLK-11A
186-1216-CLK-11B
186-1216-CB-04A
186-1216-CBM-05A
186-1216-FT-06B
186-1216-FTM-07B
186-1216-FT-08A
186-1216-FTM-09A186-1216-FT-08B
186-1216-FTM-09B
186-1216-CLK-12B
186-1216-CLK-12C
186-1216-CLK-12A