531-325 - Drawings-14-E3.pdf

PDF 4 MB Posted

Attached to
Y1DZ--TIERED EVALS - Construct Primary Care/Mental Health Building Minor Construction - Boise 531-325
Solicitation number
36C77624R0096
Issued by

About this file

This document appears to be a set of construction drawings for the Construct Primary Care/Mental Health Building Minor Construction project at the Boise VA Medical Center. The drawings include floor plans, electrical details, and site layouts for the new building. Key details include the location of the OIT server room, grounding and bonding requirements, lighting and power systems, and provisions for future solar panels. The drawings also indicate that the project will be delivered as an add alternate. This seems to be part of the larger solicitation (36C77624R0096) for the Construct Primary Care/Mental Health Building Minor Construction project at the VA Medical Center in Boise, Idaho.

View the file

Other files

File Type Posted
0005 - Tech Questions Tracker - Boise PCMH - 8-7-24.pdf PDF
36C77624R0096 0005.pdf PDF
36C77624R0096 0004.pdf PDF
0004 - Tech Questions Tracker - Boise PCMH - 8-5-24.pdf PDF
0004 - Brand Name Justification.pdf PDF
36C77624R0096 0003.pdf PDF
0003 - Tech Questions Tracker - Boise PCMH - 8-1-24.pdf PDF
36C77624R0096 0002.pdf PDF
0001 - Site Visit Sign-in - 7-16-24.pdf PDF
36C77624R0096 0001.pdf PDF
531-325 - Drawings-07-A2.pdf PDF
531-325 - SOW 4-15-24.pdf PDF
531-325 - Drawings-05-S1.pdf PDF
531-325 - Specs-Vol-1.pdf PDF
Small Business Subcontracting Plan Model.docx DOCX document
531-325 - Drawings-09-A4.pdf PDF
531-325 - Drawings-03-C2.pdf PDF
Division Cost Breakdown.xlsx XLSX spreadsheet
531-325 - Drawings-15-E4.pdf PDF
Limitations on Subcontracting - Construction.docx DOCX document
Site Visit Instructions.pdf PDF
531-325 - Drawings-16-E5.pdf PDF
531-325 - Specs-Appx-B.pdf PDF
531-325 - Drawings-04-L1.pdf PDF
531-325 - Specs-Vol-2.pdf PDF
531-325 - Drawings-10-M1.pdf PDF
531-325 - Specs-Appx-A.pdf PDF
Site Visit Map.pdf PDF
531-325 - Drawings-01-G1.pdf PDF
RFP 36C77624R0096.docx DOCX document
531-325 - Drawings-06-A1.pdf PDF
531-325 - Drawings-02-C1.pdf PDF
531-325 - Drawings-11-P1.pdf PDF
531-325 - Drawings-13-E2.pdf PDF
531-325 - Drawings-08-A3.pdf PDF
531-325 - Specs-Appx-C.pdf PDF
531-325 - Specs-Appx-E.pdf PDF
DBA Wage Rates - Ada County - 01-12-24.pdf PDF
531-325 - Drawings-12-E1.pdf PDF
531-325 - Specs-Appx-F.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

I

J

K

L

M

N

L.2

OPEN

CEILING

OPEN

CEILING

NS

W D

C

2 2 2

2 2 2

2 2

2 2

WAP WAP

WAP

WAP WAP

W

W W

W

W

90°90°

90°

360° 360°

FACP

FS

S

72" AFF

TV

WAP G

WAP G

S

UC

UC UC UC UC

UC

W D

WAP G

S

STORAGE

STORAGE

107A

GROUP ROOM

MSA & BUSINESS

SERVICES

HOUSEKEEPING

AND LADDER

POLICE

FAMILY TLT

TLT PUBLIC

LACTATION

RECEPTION

VESTIBULE

LOBBY

CORRIDOR

C10

TLT PUBLIC

TLT PUBLIC

CORRIDOR

C11

S

WAP S

2 2

FS

S

ADD ALT 12

AC

S S

S

MEDIA

CABINET

CASH

REGISTER

OVERHEAD

PROJECTOR

TYP

LEVEL 1 - SPECIAL SYSTEMS PLAN -

WEST (ADD ALT #1)

ET103A

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

PROVIDE PUSH BUTTON TO ELECTRONICALLY LOCK

BUILDING FRONT ENTRANCE

COORDINATE WITH ARCHITECTURAL PLANS FOR EXACT

EQUIPMENT/DATA OUTLET PLACEMENTS.

AUDIO/VISUAL CONTROLLER AND INPUT DEVICE. PROVIDE

COMPLETE AND FULLY FUNCTIONAL AUDIO SYSTEM. AUDIO

SYSTEM SHALL INTEGRATE WITH OVERHEAD PROJECTOR

AND SPEAKER SYSTEM. COORDINATE WITH A/V

CONTRACTOR AND ARCHITECT FOR FINAL INSTALLATION

LOCATIONS.

PROVIDE DATA CONNECTIONS TO VAV ACTUATOR AND

VALVE FROM DDC CONTROLLER LOCATED IN ROOM 180.

COORDINATE WITH MECHANICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

GENERAL SHEET NOTES

ET103A

MATCHLINE

TO SHEET ET102AMATCHLINE TO SHEET ET102A

1/4" = 1'-0"1 LEVEL 1 - SPECIAL SYSTEMS PLAN - WEST (ADD ALT #1)

0 4' 8' 16'

PROJECT

NORTH

1. DATA CABLING SHALL ROUTE BACK TO OIT SERVER ROOM

171.

2. FIRE ALARM CABLING SHALL ROUTE TO FACP LOCATED IN

VESTIBULE 101.

3. CONTRACTOR SHALL COORDINATE THERMOSTAT LOCATIONS

WITH MECHANICAL CONTRACTOR AND PROVIDE CONDUIT,

BOX AND PULL STRING.

4. COORDINATE FINAL FLOOR BOX LOCATIONS WITH

ARCHITECT PRIOR TO INSTALLATION.

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LRL / BJR JPS / FEB

8056 SF

MECH

PENTHOUSE

1 2 3 42.5

ET104

2 32.1 2.92.5

ROOF AND MECHANICAL PENTHOUSE -

SPECIAL SYSTEMS PLANS

ET104

ET104

KEY PLAN

GENERAL SHEET NOTES

1. DATA CABLING SHALL ROUTE BACK TO OIT SERVER ROOM

171.

2. FIRE ALARM CABLING SHALL ROUTE TO FACP LOCATED IN

VESTIBULE 101.

3. CONTRACTOR SHALL COORDINATE THERMOSTAT

LOCATIONS WITH MECHANICAL CONTRACTOR AND PROVIDE

CONDUIT, BOX AND PULL STRING.

ET104

S1

S1

KEY NOTES (THIS SHEET ONLY)

AHU-1 DUCT SMOKES PROVIDED ON BOTH SUPPLY AND

RETURN. COORDINATE WITH MECHANICAL DRAWINGS AND

AHU MANUFACTURER FOR EXACT LOCATIONS.

1/4" = 1'-0"1 ROOF AND MECHANICAL PENTHOUSE - SPECIAL SYSTEMS PLAN

1/4" = 1'-0"2 ENLARGED MECHANICAL PENTHOUSE - SPECIAL SYSTEMS PLAN

0 4' 8' 16'

PROJECT

NORTH 0 4' 8' 16'

PROJECT

NORTH

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Office of

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

LRL/BJR JPS/FEB 184 OF 206

8056 SF

MECH

PENTHOUSE

CON_CENTERCON_TYPE

CON_WIDTH

CON_LENGTH

1 2 3 42.5

ET104

2 32.1 2.92.5

ROOF AND MECHANICAL PENTHOUSE -

SPECIAL SYSTEMS PLANS

(ADD ALT #2)

ET104A

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

SOLAR EQUIPMENT. COORDINATE WITH SOLAR DRAWINGS

FOR DATA CONNECTION. DATA CONNECTION SHALL

HOMERUN BACK TO OIT SERVER ROOM 171. PROVIDE

CONNECTIONS AS REQUIRED. ALL SOLAR EQUIPMENT SHALL

BE ADD ALT 2.

AHU-1 DUCT SMOKES PROVIDED ON BOTH SUPPLY AND

RETURN. COORDINATE WITH MECHANICAL DRAWINGS AND

AHU MANUFACTURER FOR EXACT LOCATIONS.

GENERAL SHEET NOTES

1. DATA CABELING SHALL ROUTE BACK TO OIT SERVER ROOM

171.

2. FIRE ALARM CABELING SHALL ROUTE TO FACP LOCATED IN

VESTIBULE 101.

3. CONTRACTOR SHALL COORDINATE THERMOSTAT LOCATIONS

WITH MECHANICAL CONTRACTOR AND PROVIDE CONDUIT,

BOX AND PULL STRING

ADD ALT 2

ADD ALT 2

ET104A

ET104A

S1

S1

1/4" = 1'-0"1 ROOF AND MECHANICAL PENTHOUSE - SPECIAL SYSTEMS PLAN

1/4" = 1'-0"2 ENLARGED MECHANICAL PENTHOUSE - SPECIAL SYSTEMS PLAN

0 4' 8' 16'

PROJECT

NORTH 0 4' 8' 16'

PROJECT

NORTH

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LRL / BJR JPS / FEB

ADD ALT 21

1 2 3 4

B

C

D

E

F

G

H

I

J

K

L

M

N

L.2

A.1

2.5

B.8

A

OPEN

CEILING

OPEN

CEILING

EG101

G-001

1TYP

E-501

TYP

G-003 TYP

1 TYP

Xref ..\..\Markups\Markups_21.05.11\XREF CAD\531-325 Floorplan Xref.dwg

OFFICE

OFFICE

SOILED MED

EQUIP

S TLT

STAFF LOUNGE

MECH

STAFF LOCKERS

STAFF LOCKERS

STAFF LOCKERS

STAFF LOCKERS

EXAM ROOM 07

EXAM ROOM 06

EXAM ROOM 05

EXAM ROOM 04

EXAM ROOM 14

EXAM ROOM 13

EXAM ROOM 12

EXAM ROOM 11

P TLT

ALCOVE

S TLT

CORRIDOR

C13

S TLT

S TLT

CORRIDOR

C15

PACT TEAM

EXAM ROOM 03

EXAM ROOM 02

EXAM ROOM 01

WOMEN'S

HEALTH 01

EXAM ROOM 10

EXAM ROOM 09

EXAM ROOM 08

PROCEDURE

ROOM 01

WH TLT

118A

CLEAN SUPPLY

ALCOVE, H/W

ALCOVE, H/W

CORRIDOR

C12

CORRIDOR

C14

CORRIDOR

C13

PACT TEAM

STORAGE

108STORAGE

107A

GROUP ROOM

MSA & BUSINESS

SERVICES

HOUSEKEEPING

AND LADDER

POLICE

FAMILY TLT

TLT PUBLIC

LACTATION

RECEPTION

VESTIBULE

LOBBY

CORRIDOR

C10

TLT PUBLIC

TLT PUBLIC

CORRIDOR

C11

G-002

G-005

G-004

E-501

E-501

E-501 2

E-501

LEVEL 1 - OVERALL

GROUNDING PLAN

EG101

EG101

KEY PLAN

GENERAL SHEET NOTES

1. GROUND RING DEPTH SHALL BE 30" MINIMUM.

0 4' 8' 16'

ENLARGED ELECTRICAL ROOM AND

SERVER ROOM GROUNDING PLAN

0 1' 2' 4'

EG101

KEY NOTES (THIS SHEET ONLY)

1 GROUND RING SHALL BE BONDED TO BUILDING STEEL WITH

UL LISTED EXOTHERMIC GROUND BOND OR EQUAL.

GROUND RING SPACING FROM FOUNDATION STEM WALL

SHALL BE 3'0".

CB-EMDP1

EMDP1

CB-NMDP1

NMDP1 PANELBOARD "12"

PANELBOARD "11"

ELEC

OIT SERVER

OIT SERVER

ELEC

1/8" = 1'-0"1 LEVEL 1 - OVERALL GROUNDING PLAN

1/2" = 1'-0"2

PROJECT

NORTH

PROJECT

NORTH

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LRL / BJR JPS / FEB 186 OF 206

1 2 3 4

B

C

D

E

F

G

H

I

J

K

L

M

N

1.1 3.9

L.2

A.1

2.1 2.9

2.5

B.8

A

OPEN

CEILING

OPEN

CEILING

EG101

G-001

1TYP

E-501

TYP

G-003 TYP

1 TYP

Xref ..\..\Markups\Markups_21.05.11\XREF CAD\531-325 Floorplan Xref.dwg

OFFICE

OFFICE

SOILED MED

EQUIP

S TLT

STAFF LOUNGE

MECH

STAFF LOCKERS

STAFF LOCKERS

STAFF LOCKERS

STAFF LOCKERS

EXAM ROOM 07

EXAM ROOM 06

EXAM ROOM 05

EXAM ROOM 04

EXAM ROOM 14

EXAM ROOM 13

EXAM ROOM 12

EXAM ROOM 11

EXAM ROOM 21

EXAM ROOM 20

EXAM ROOM 19

EXAM ROOM 18

EXAM ROOM 28

EXAM ROOM 27

EXAM ROOM 26

EXAM ROOM 25

PACT TEAM

P TLT

P TLT

ALCOVE

ALCOVE

S TLT

CORRIDOR

C13

S TLT

S TLT

CORRIDOR

C15

PACT TEAM

EXAM ROOM 03

EXAM ROOM 02

EXAM ROOM 01

WOMEN'S

HEALTH 01

EXAM ROOM 10

EXAM ROOM 09

EXAM ROOM 08

PROCEDURE

ROOM 01

WH TLT

118A

PROCEDURE

ROOM 01

EXAM ROOM 15

EXAM ROOM 16

EXAM ROOM 17

PACT TEAM

EXAM ROOM 24

EXAM ROOM 23

EXAM ROOM 22

WH TLT

163A

WOMEN'S

HEALTH 02

163CLEAN SUPPLY

CLEAN SUPPLY

ALCOVE, H/W

ALCOVE, H/W

CORRIDOR

C12

CORRIDOR

C14

CORRIDOR

C13

PACT TEAM

STORAGE

108STORAGE

107A

GROUP ROOM

MSA & BUSINESS

SERVICES

HOUSEKEEPING

AND LADDER

POLICE

FAMILY TLT

TLT PUBLIC

LACTATION

RECEPTION

VESTIBULE

LOBBY

CORRIDOR

C10

TLT PUBLIC

TLT PUBLIC

CORRIDOR

C11

G-002

G-005

G-004

E-501

E-501

E-501 2

E-501

LEVEL 1 - OVERALL

GROUNDING PLAN

(ADD ALT #2)

EG101A

KEY PLAN

GENERAL SHEET NOTES

1. GROUND RING DEPTH SHALL BE 30" MINIMUM.

0 4' 8' 16'

KEY NOTES (THIS SHEET ONLY)

1 GROUND RING SHALL BE BONDED TO BUILDING STEEL WITH

UL LISTED EXOTHERMIC GROUND BOND OR EQUAL.

GROUND RING SPACING FROM FOUNDATION STEM WALL

SHALL BE 3'0".

CB-EMDP1

EMDP1

CB-NMDP1

NMDP1

PANELBOARD "12"

PANELBOARD "11"

DISC-PV

ELEC

OIT SERVER

OIT SERVER

ELEC

ADD ALT 2

EG101A

EG101A

ENLARGED ELECTRICAL ROOM AND

SERVER ROOM GROUNDING PLAN

0 1' 2' 4'

1/8" = 1'-0"1 LEVEL 1 - OVERALL GROUNDING PLAN (ADD ALT #2)

1/2" = 1'-0"2

PROJECT

NORTH

PROJECT

NORTH

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

LRL / BJR JPS / FEB 187 OF 206

LEVEL 1

0' - 0"

PENTHOUSE

16' - 6"

BO ROOF DECK - GABLE

35' - 3 1/2"

1 2 3 42.5

BO DECK - ENTRY

12' - 8"

S6 S6 S6 S6

S6 S6 S6 S6 S6S3 S3

LEVEL 1

0' - 0"

LEVEL 1

0' - 0"

PENTHOUSE

16' - 6"

BO ROOF DECK - GABLE

35' - 3 1/2"

B C D E F G H I J K L M NA

BO DECK - LOW ROOF

13' - 7 1/2" BO DECK - ENTRY

12' - 8" S6S6S3

S6S6 S3S3S3S3S3

GENERAL SHEET NOTES

1. EXTERIOR ELEVATIONS ARE FOR GENERAL PLACEMENT

LOCATIONS OF LIGHT FIXTURES AND SECURITY CAMERAS.

CONTRACTOR SHALL COORDINATE FINAL LOCATIONS WITH

ARCHITECTURAL ELEVATIONS.

EXTERIOR ELEVATIONS

E-201

3/16" = 1'-0"1 WEST EXTERIOR ELEVATION

3/16" = 1'-0"1 WEST EXTERIOR ELEVATION

3/16" = 1'-0"2 NORTH EXTERIOR ELEVATION

0 4' 8' 12'

0 4' 8' 12'

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

LRL / BJR JPS / FEB 188 OF 206

S6

LEVEL 1

0' - 0"

PENTHOUSE

16' - 6"

BO ROOF DECK - GABLE

35' - 3 1/2"

23 1.13.9 2.5

BO DECK - ENTRY

12' - 8"

S3 S6

S3

S3 S6

LEVEL 1

0' - 0"

PENTHOUSE

16' - 6"

BO ROOF DECK - GABLE

35' - 3 1/2"

BCDEFGHIJKLMN A

S6 S6 S6

S3 S3 S3 S3 S3

GENERAL SHEET NOTES

1. EXTERIOR ELEVATIONS ARE FOR GENERAL PLACEMENT

LOCATIONS OF LIGHT FIXTURES AND SECURITY CAMERAS.

CONTRACTOR SHALL COORDINATE FINAL LOCATIONS WITH

ARCHITECTURAL ELEVATIONS.

EXTERIOR ELEVATIONS

E-202

3/16" = 1'-0"1 3/16" = 1'-0"1 EAST EXTERIOR ELEVATION

3/16" = 1'-0" 3/16" = 1'-0"2 SOUTH EXTERIOR ELEVATION

S6

0 4' 8' 12'

0 4' 8' 12'

SOLAR PANELS

(ADD ALT 2)

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

LRL / BJR JPS / FEB 189 OF 206

1 D

5 5

UPS-1

UPS-2

EMDP1-11

EMDP1-11

EMDP1-11

E-501

S-009

RC-001

RC-001

12-62,64

EMDP1-28,30

E-503

TYP

12-66,68

EMDP1-32,34

N C

T

EMDP1-2

90°

TYP

NMDP1

CB-EMDP1

CB-NMDP1

12-11

12-11

EMDP1

PE-001

PN-001

PE-002

PN-002

PN-005

PN-006

DISC-PV

E-501

PN-003

LIGHTING CONTACTOR 15

ENLARGED PLANS

E-401

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

ALL RECEPTACLES AND EQUIPMENT IN ROOM 'OIT SERVER

171' SHALL BE CONNECTED TO UPS POWER, AND THE UPS

EQUIPMENT CONNECTED TO THE CRITICAL BRANCH OF THE

ESSENTIAL ELECTRICAL SYSTEM.

PAINTED 3/4" FIRE RETARDANT PLYWOOD BACKBOARD

'TB-1'. SEE DETAIL 6 ON E-502.

OIT SPECIAL SYSTEMS RACK IN LOCKABLE ENCLOSURE.

FACILITY MANAGEMENT SERVICE SYSTEMS RACK IN

LOCKABLE ENCLOSURE.

SPECIAL SYSTEMS EQUIPMENT, COORDINATE WITH VA FOR

FINAL LOCATION.

CABLE TRAY SHALL BE MOUNTED SUCH THAT BOTTOM OF

TRAY IS 6” ABOVE TOP OF RACK OR CABINET.

CAMERA SUSPENDED BELOW CABLE TRAY.

RE-USABLE PENETRATION FIRESTOPPING SYSTEM. TYPE

AND SIZE AS REQUIRED TO MATCH CABLE TRAY. EASY PATH

OR APPROVED EQUAL.

LEVTRON PATCH PANEL.

CONTINUED ON SHEET ES101.

WALL MOUNT FIBER PATCH PANEL

TWIST LOCK, 30A, 208V RECEPTACLES. MOUNT

RECEPTACLES ABOVE TELECOM RACKS; COORDINATE

INSTALLATION WITH RACKS & CABLE TRAY AS REQUIRED.

HOUSE KEEPING PAD, CONCRETE, 3-1/2" THICK, CHAMFERED

EDGE.

CONTRACTOR SHALL COORDINATE ALL DATA CABLING

ROUTING TO AVOID HIGH CEILING AREAS. REFERENCE

DRAWING ET101 FOR ADDITIONAL INFORMATION.

LIGHTING CONTACTOR, 4-POLE, 30A, 120V CONTACTOR,

NEMA 1 ENCLOSURE. CONTACTOR SHALL BE CONTROLLED

VIA PHOTOCELL LOCATED ON ROOF. REFERENCE DRAWING

EL104 FOR ADDITIONAL INFORMATION.

GENERAL SHEET NOTES

1. OIT SWITCHES & PATCH CABLES WILL BE VA FURNISHED, VA

INSTALLED.

2. NOT ALL CONDUIT MAY BE SHOWN FOR CLARITY.

REFERENCE CONDUIT AND WIRE SCHEDULE ON SHEET E-603

FOR ADDITIONAL INFORMATION.

0 1' 2' 4' 0 1' 2' 4'

E401

E401

E401

PROJECT

NORTH

1/2" = 1'-0"1 ENLARGED OIT SERVER 171 ROOM ELECTRICAL PLAN

1/2" = 1'-0"2 ENLARGED COMC1 OIT SERVER ROOM 171 SPECIAL SYSTEMS FLOOR PLAN

1/2" = 1'-0"3 ENLARGED ELEC 170 ROOM FLOOR PLAN

1/2" = 1'-0"4 NOT USED

0 1' 2' 4'

PROJECT

NORTH

PROJECT

NORTH

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LRL / BJR JPS / FEB

1 D

5 5

UPS-1

UPS-2

EMDP1-11

EMDP1-11

EMDP1-11

E-501

S-009

RC-001

RC-001

12-62,64

EMDP1-28,30

E-503

TYP

12-66,68

EMDP1-32,34

N C

T

EMDP1-2

TYP

NMDP1

CB-EMDP1

CB-NMDP1

12-11

12-11

EMDP1

PE-001

PN-001

PE-002

PN-002

PN-005

PN-006

DISC-PV

E-501

PN-003

LIGHTING CONTACTOR 15

ADD ALT 2

ENLARGED PLANS (ADD ALT #2)

E-401A

KEY PLAN

0 1' 2' 4'

KEY NOTES (THIS SHEET ONLY)

ALL RECEPTACLES AND EQUIPMENT IN ROOM 'OIT SERVER

171' SHALL BE CONNECTED TO UPS POWER, AND THE UPS

EQUIPMENT CONNECTED TO THE CRITICAL BRANCH OF THE

ESSENTIAL ELECTRICAL SYSTEM.

PAINTED 3/4" FIRE RETARDANT PLYWOOD BACKBOARD

'TB-1'. SEE DETAIL 6 ON E-502.

OIT SPECIAL SYSTEMS RACK IN LOCKABLE ENCLOSURE.

FACILITY MANAGEMENT SERVICE SYSTEMS RACK IN

LOCKABLE ENCLOSURE.

SPECIAL SYSTEMS EQUIPMENT, COORDINATE WITH VA FOR

FINAL LOCATION.

CABLE TRAY SHALL BE MOUNTED SUCH THAT BOTTOM OF

TRAY IS 6” ABOVE TOP OF RACK OR CABINET.

CAMERA SUSPENDED BELOW CABLE TRAY.

RE-USABLE PENETRATION FIRESTOPPING SYSTEM. TYPE

AND SIZE AS REQUIRED TO MATCH CABLE TRAY. EASY PATH

OR APPROVED EQUAL.

LEVTRON PATCH PANEL.

CONTINUED ON SHEET ES101.

WALL MOUNT FIBER PATCH PANEL

TWIST LOCK, 30A, 208V RECEPTACLES. MOUNT

RECEPTACLES ABOVE TELECOM RACKS; COORDINATE

INSTALLATION WITH RACKS & CABLE TRAY AS REQUIRED.

HOUSE KEEPING PAD, CONCRETE, 3-1/2" THICK, CHAMFERED

EDGE.

CONTRACTOR SHALL COORDINATE ALL DATA CABLING

ROUTING TO AVOID HIGH CEILING AREAS. REFERENCE

DRAWING ET101 FOR ADDITIONAL INFORMATION.

LIGHTING CONTACTOR, 4-POLE, 30A, 120V CONTACTOR,

NEMA 1 ENCLOSURE. CONTACTOR SHALL BE CONTROLLED

VIA PHOTOCELL LOCATED ON ROOF. REFERENCE DRAWING

EL104 FOR ADDITIONAL INFORMATION.

GENERAL SHEET NOTES

1. OIT SWITCHES & PATCH CABLES WILL BE VA FURNISHED, VA

INSTALLED.

2. NOT ALL CONDUIT MAY BE SHOWN FOR CLARITY.

REFERENCE CONDUIT AND WIRE SCHEDULE ON SHEET E-603

FOR ADDITIONAL INFORMATION.

E401A

E401A

E401A

0 1' 2' 4' 1/2" = 1'-0"1 ENLARGED OIT SERVER 171 ROOM ELECTRICAL PLAN

1/2" = 1'-0"2 ENLARGED COMC1 OIT SERVER ROOM 171 SPECIAL SYSTEMS FLOOR PLAN

1/2" = 1'-0"3 ENLARGED ELEC 170 ROOM FLOOR PLAN (ADD ALT #2)

1/2" = 1'-0"4 NOT USED

0 1' 2' 4'

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LRL / BJR JPS / FEB

GROUND ROD,

COPPER CLAD,

10'L X 3/4"Ø

MAKE THIS LOOP

AS LARGE AS

POSSIBLE, AVOID

A SHARP BEND

BURNDY GROUND

CLAMP

FILL WITH SOIL, TO

WITHIN 6" OF TOP

OF ROD, COMPACT

BY ADDING WATER

AND TAMPING

GROUND RING (WHERE

PROVIDED)

SCHEDULE 80 PVC

CONDUIT TO SERVICE

EQUIPMENT

FOGTITE GROUND ROD

BOX SP-1 OR EQUAL

3"

CONCRETE STEEL INSERT

FOR TRAFFIC AREAS,

CONCRETE ONLY FOR

NON- TRAFFIC USE AREAS

30"

MINIMUM

4" SQUARE JUNCTION

BOX

1/2" CONDUIT

DOOR HINGE POSITION

CONTACT (TYPICAL)

1" CONDUIT

SUSPENDED

CEILING

3/4" CONDUIT

SINGLE-GANG

JUNCTION BOX (BY EC)

ON INTERIOR SIDE

OF DOOR FOR CARD

READER

1" CONDUIT

1" CONDUIT TO SECURITY

HEAD-END EQUIPMENT

INTELECOM ENCLOSURE

3/4" CONDUIT

120V POWER TO

POWER SUPPLY/CONTROLLER

3/4" CONDUIT

WITH FIRE ALARM

OVERRIDE CONDUCTORS

DOOR LATCH POWER SUPPLY

J

J

1. SINGLE MAGNETIC LOCK RATED AT .5 AMPS AT 24VDC. #16 CONDUCTORS

INDICATED ARE FOR UP TO 500 FEET FROM DOOR CONTROLLER, UPSIZE

CONDUCTORS FOR LONGER RUNS.

2. TWO MAGNETIC LOCKS RATED AT .5 AMPS EACH AT 24VDC. #14 CONDUCTORS

INDICATED ARE FOR UP TO 500 FEET FROM DOOR CONTROLLER, UPSIZE

CONDUCTORS FOR LONGER RUNS.

3. EXIT BUTTON SHALL BE DOUBLE POLE MOMENTARY ACTION. ONE POLE SHALL

DIRECTLY BREAK THE CURRENT TO THE MAGNETIC LOCK. THE OTHER POLE

SHALL BE USED AS AN INPUT TO THE DOOR CONTROLLER TO RELEASE THE

MAGNETIC LOCK FOR PROGRAMMED TIME PERIOD ON ACTIVATION.

4. ACCESS CONTROL SYSTEM EQUIPMENT PROVIDED BY EQUIPMENT PROVIDER,

INSTALLED BY EC.

DETAIL NOTES

SINGLE-GANG

JUNCTION BOX (BY EC)

ON EXTERIOR SIDE OF

DOOR FOR CARD

READER

(BY VA)

4" SQUARE J-BOX PROVIDING

PATHWAY FROM

POWER SUPPLY/CONTROLLER TO

DOOR VIA FRAME

TRANSFER HARWARE.

MAGNETIC LOCK. QUANTITY

AND TYPE PER SYSTEM

REQUIREMENTS.

STEEL BEAM

CADWELD CONNECTION

TYPE QW (OR TYPE VN TO

WEB OF LARGE BEAM)

STEEL COLUMN

CADWELD CONNECTION

TYPE VV

TO GROUND

EXOTHERMIC WELD

CONNECTION

NO. GBIT14412M-22T OR APPROVED

EQUAL, 1/4" x 4" x 12" SOLID COPPER

GROUND BAR WITH INSULATORS AND

BRACKETS, AND WITH TWO 25'-0" NO. 2T,

#2 AWG TIN COATED COPPER GROUND

CONDUCTORS

#2AWG SOLID

TINNED CU X

25FT LO

NG

ITEM

CONCRETE ENCASED REBAR (UFER)

GROUND RODS (IF WITHOUT GROUND RING)

GROUND RING (WITH OR WITHOUT GROUND RODS AS NOTED)

SIZE

METAL WATER PIPES

OTHER CONNECTIONS AS NOTED ON PLANS

STRUCTURAL STEEL

SPECIAL SYSTEMS GROUNDING BUS BARS

POWER CABLE TRAY, SPECIAL SYSTEMS CABLE TRAY

#3/0 #6 #2

#3/0 #6

#3/0 #2

GAS PIPES

GROUNDING ELECTRODE AND BONDING CONDUCTOR SIZING SCHEDULE

* BY EQUIPMENT MANUFACTURER, PER NEC 250.66

GROUNDING ELECTRODE CONDUCTOR #3/0

ANTENNA MAST TELECOM RACK ENCLOSURES #2

#3/0

MAIN BONDING JUMPER

INTERSYSTEM BONDING BUS BAR

#6 #3/0

#6

1. MAKE CONNECTION TO ALL AVAILABLE ELECTRODES. NOT ALL MAY BE PRESENT.

2. ALL GROUNDING AND BONDING TO BE IN ACCORDANCE WITH THE CURRENT VERSION

OF THE NEC THAT HAS BEEN ACCEPTED FOR USE IN EACH JURISDICTION AND AS

AMENDED BY LOCAL AUTHORITY HAVING JURISDICTION.

3. GROUND RODS TO BE INSTALLED OUTSIDE OF BUILDING ROOF'S DRIP LINE.

4. ALL GROUNDING CONDUCTORS SHALL BE STRANDED COPPER.

DETAIL NOTES

ITEM SIZE

UFER

GROUND

METAL

WATER

PIPES

OTHER

CONNECTIONS

AS

NOTED

ON

THE

PLANS

STRUCTURAL

STEEL

SPECIAL

SYSTEMS

GROUNDING

BUS

BARS

SPECIAL

SYSTEMS

CABLE

TRAY

SIZE PER TABLE

BELOW, TYPICAL

BOND AT

LOCATIONS

REQUIRED TO

MAINTAIN

CONTINUITY

GROUND

RODS

MINIMUM

6'-0"

OR

20'-0"

SPACING

WHERE

GROUND

RING

PROVIDED

GROUND RING

CONDUCTOR

WHERE PROVIDED

NEUTRAL BUSGROUND BUS

MAIN BONDING

JUMPER

POWER

CABLE

TRAY

SERVICE

EQUIPMENT

GROUNDING

ELECTRODE

CONDUCTOR

SERVICE GROUND

BUS BAR -

E-501

E-501

E-501

ELECTRICAL DETAILS

E-501

3"

3"

4"

3"3"3" 3"

3" 3"

12"

BACKFILL TO MATCH

EXISTING GRADE

ASPHALT OR CONCRETE PAVING

PAVING BASE

SELECTED BACKFILL FREE

OF LARGE DEBRIS AND

COMPACTED PER VA

SPECIFICATIONS

CONCRETE SLURRY MIX

MEETING VA STANDARDS

CONCRETE ENCASEMENT

IF REQUIRED AS SHOWN

ON PLANS

CONTINUOUS WARNING

TAPE. TRACER WIRE

SHALL BE ACCESSIBLE IN

ALL HAND HOLES OR MAN

HOLE

X" MIN.

24"

MIN.

3"

PROVIDE AND SIZE

CONDUITS PER PLANS

FOR POWER TO CATV AND

TELEPHONE SEPARATION

PROVIDE 12" CLEARANCE

RESURFACE IN ACCORDANCE

WITH FINAL

REQUIREMENTS-SOD IN LAWN

AREAS, ASPHALT IN PAVED

AREAS

INSTALL YELLOW PLASTIC

IDENTIFICATION STRIP AT 12"

DEEP THE FULL LENGTH, WITH

METALLIC TRACER WIRE THE

FULL LENGTH, LABLED "DANGER

BURIED ELECTRICAL"

6" OR MORE OF CLEAN SAND OR

APPROVED EXCAVATED

MATERIAL

36" MINIMUM BURIAL DEPTH

FOR UTILITIES

INCLUDING POWER,

DATA AND

TELEPHONE OR AS

AMENDED BY THE

SERVING UTILITY. 24" MINIMUM

BURIAL DEPTH FOR

SITE LIGHTING/POWER

BACKFILL 95%

COMPACTION

CONDUIT TYPE, SIZE, AND

QUANTITY AS SPECIFIED

7-1/2" 7-1/2"

FINISHED GRADE

GRS, WRAPPED WITH CORROSION RESISTANT TAPE.

FINISHED GRADE

3/4" GRAVEL (MINIMUM

DIMENSIONS SHOWN.

INCREASE AS NEEDED

TO ENSURE DRAINAGE.)

COVER

FLUSH WITH GRADE

CONDUIT BUSHINGS

24"

MIN.

6"

6"

MIN.

6"

PVC

ELECTRIC HANDHOLE,

12"W x 18"'L (MIN.)

WATERPROOF

SPLICE KIT

SCALE: NTS1 GROUNDING ELECTRODE AND BONDING SYSTEM

SCALE: NTS2 INTERSYSTEM AND SERVICE GROUNDING

TYPICAL GROUND BUS BAR FOR

SCALE: NTS3 BUILDING STEEL GROUND

SCALE: NTS4 TYPICAL GROUND WELL

SCALE: NTS5 TELECOMMUNICATIONS TRENCHING SECTION

TYPICAL MV AND BUILDING

SCALE: NTS6 (MAGNETIC LOCK TYPE)

SECURITY ACCESS DOOR CONTROL

SCALE: NTS7 TYPICAL TRENCHING SECTION

SCALE: NTS8 TYPICAL LIGHTING HANDHOLE SECTION

FINISHED GRADE

3/4" GRAVEL (MINIMUM

DIMENSIONS SHOWN. INCREASE

AS NEEDED TO ENSURE

DRAINAGE.)

COVER

FLUSH WITH GRADE

CONDUIT BUSHINGS

24"

MIN.

6"

MIN.

6"

6"

PVC

SIGNAL HANDHOLE,

12"W x 18"L (MIN.)

GALVANIZED RIGID STEEL,

WRAPPED WITH CORROSION

RESISTANT TAPE.

SCALE: NTS9 TYPICAL SURVEILLANCE HANDHOLE SECTION

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LRL / BJR JPS / FEB

GAS

PIPES

SCALE: NTS10

LINE VOLTAGE OCCUPANCY/VACANCY

SENSOR W/DIMMING SCHEMATIC

PHASE

DIMMING

MODULE

LIGHTING

LOADS

COMM

CNTRL

LINE

VOLTAGE

DIMMER

SWITCH

OCCUPANCY/

VACANCY

SENSOR

CONTROL

STATION

DIMMER

SWITCH

DETAIL NOTES

1. COORDINATE INSTALLATION WITH SPECIFIC MANUFACTURER'S INSTALLATION

REQUIREMENTS AND WIRING DIAGRAMS, PROVIDE ALL BOXES, RACEWAY,

COMPONENTS AND CONDUCTORS AS REQUIRED FOR COMPLETE OPERATIONAL

SYSTEM.

2. ALL CONDUCTORS SHALL BE 600V RATED UNLESS OTHERWISE NOTED.

3. PHASE DIMMING MODULES SHALL BE LOCATED WITHIN ACCESSIBLE CEILING

SPACE OR ACCESSIBLE WALL SPACE (PROVIDE WALL KIT AS REQUIRED) WITHIN

5' OF DOOR FOR ROOM SERVED WHERE POSSIBLE.

4. OCCUPANCY SENSOR SHALL BE PROVIDED WITH AUXILIARY RELAY FOR

CONNECTION TO HVAC CONTROL SYSTEM AND SHALL BE UL916 LISTED FOR

ENERGY MANAGEMENT.

5. ALL WIRING CONCEALED WITHIN WALLS OR ABOVE HARD-LID CEILING SHALL BE

ROUTED WITHIN RACEWAY.

C O

M M

C N

TR

L

RF COMMUNICATION

RF COMMUNICATION

NEU

HOT

LIGHTING

CIRCUIT

PROVIDE

ADDITIONAL

SENSORS

AS

REQUIRED/

INDICATED

PROVIDE

ADDITIONAL

SWITCHES

AS

REQUIRED/

INDICATED

DAYLIGHT

SENSOR

HOT

NEU

AND DAYLIGHT

ALL WIRING CONCEALED WITHIN WALLS OR ABOVE HARD-LID CEILING SHALL BE

ROUTED WITHIN RACEWAY.

CONDUIT CLAMP

AND HANGER - 3'

MAX. FROM BOX

TO HANGER & 8'

MAX. SPACING

BETWEEN

HANGERS (TYP.)

STEEL OUTLET

BOX - SIZED

PER N.E.C.

AND

SUPPORTED

RIGIDLY FROM

STRUCTURE

(TYP.)

CONDUIT (TYP.)

6' MAX. LENGTH FLEX

CONDUIT W/ (3)#12

CONDUCTORS INTO

FIXTURE (TYP.)

TYPICAL LAY-IN

RECESSED

LIGHT FIXTURE

(TYP.)

SECURE FIXTURES TO

GRID WITH CLIPS PER

N.E.C. (TYP.)

T-BAR LAY-IN

CEILING

SUSPENSION

SYSTEM (TYP.)

PROVIDE

SUPPORT WIRES

TO STRUCTURE

FOR FIXTURE

SUPPORT, TWO

PER FIXTURE

(TYP.) SEE SPEC

SECTION

265100.

1. DO NOT SUPPORT CONDUIT OR BOX FROM CEILING GRID HANGERS.

DETAIL NOTES

JOIST (TYP.)

FACP

AHU-1

SHUTDOWN

SPARE

SPARE

NOTIFICATION

CIRCUIT

QTY=4 SMOKE,

HEAT, DUCT

DETS PULL

STATIONS

QTY=1

BATTERIES

120 VAC FIBER OPTIC CABLE.

FIBER NETWORK CARD

TELEPHONE/CATV

TERMINAL BOARD

SIZE AS INDICATED

ON PLANS.

NETWORK/VOICE

(TYP.)

VOICE

(TYP.)

TV

OUTLET

2"C w/(2)-RG11/U TO CABLE TV SERVICE

4" CONDUIT TO TELEPHONE COMPANY

MAIN SERVICE

6 AWG 3/4" C.

COPPER TO

SERVICE

GROUND OR

INTERSYSTEM

BONDING BUS

3/4"C w/

(1)-CAT6

3/4"C w/

(1)-CAT6

3"C 3/4"C w/(1)-RG6/U

AND (1)-CAT6

ALARM

CIRCUIT

TAMPER, FLOW

SENSORS

120V

DEDICATED

CIRCUIT

1. FIRE ALARM SYSTEM AS SHOWN IS SCHEMATIC ONLY AND DOES NOT INDICATE ALL DEVICES, EQUIPMENT, WIRING. PROVIDE COMPLETE SYSTEM WITH ALL REQUIRED DEVICES AND EQUIPMENT

AND SUBMIT ENGINEERED DRAWINGS TO AHJ FOR REVIEW AND APPROVAL.

DETAIL NOTES

1. COMMUNICATIONS DIAGRAM AS SHOWN IS SCHEMATIC AND DOES NOT INDICATE ALL DEVICES, EQUIPMENT, WIRING. PROVIDE COMPLETE SYSTEM WITH ALL REQUIRED DEVICES AND EQUIPMENT.

DETAIL NOTES

ACCESSIBLE

CEILING

TV

ELECTRICAL DETAILS

E-502

POLE BASE

PLATE

LEVELING NUTS

GRADE

GROUT

CHAMFER

HAND HOLE

POLE

BUSHING

COVER PLATE

1. CONTRACTOR MAY CHOOSE TO PROVIDE ADJACENT HANDHOLE FOR POWER/CONTROL

WIRING AND EASE OF CONSTRUCTABILITY. HANDHOLE TO BE APPROPRIATELY RATED

FOR SURFACE BEING INSTALLED WITHIN. COORDINATE LOCATION WITH

LANDSCAPING AND ALL OTHER ADJACENT ELEMENTS.

DETAIL NOTES

18" DIAMETER

PVC CONNECTION

PVC SCHEDULE 40

UNLESS OTHERWISE NOTED

MUST INCLUDE GROUND WIRE

GALVANIZED RIGID STEEL CONDUIT OR

SCHEDULE 80PVC. WRAP STEEL CONDUIT

WITH UL LISTED CORROSION RESISTANT

TAPE WHERE IN CONTACT WITH EARTH

ANCHOR BOLTS PER MANUFACTURER'S

RECOMMENDATIONS

REINFORCED STEEL #4

VERTICALLY #4

HORIZONTALLY AT 12" O.C.

PVC SCHEDULE 40

UNLESS OTHERWISE

NOTED

MUST INCLUDE

GROUND WIRE (2ND

POWER CONDUIT

WHERE REQUIRED)

24" MIN

48"

FS

TS

QTY=12 QTY=6

FNC

TO FA

NETWORK

TIE REINFORCING BARS AT

EVERY INTERSECTION.

POWER

POWER

COMMON

CONTROL

CONTROL

COMMON

POWER

CONTROL

COMMON

NEUTRAL

HOT

PO

W

ER

PACK

C O

M M

O N

C O

N

TR

O L

POWER

MOUNT IN

ACCESSIBLE

SPACE

LUMINARIES

AS

REQUIRED/

INDICATED

CLNG./WALL

SENSOR

1. COORDINATE INSTALLATION WITH SPECIFIC MANUFACTURER'S INSTALLATION REQUIREMENTS AND WIRING DIAGRAMS. PROVIDE ALL BOXES, RACEWAY, COMPONENTS AND CONDUCTORS AS REQUIRED

FOR COMPLETE OPERATIONAL SYSTEM.

2. ALL CONDUCTORS SHALL BE 600V RATED UNLESS OTHERWISE NOTED.

3. POWER PACKS SHALL BE LOCATED WITHIN ACCESSIBLE CEILING SPACE WITHIN 5' OF DOOR FOR

ROOM SERVED WHERE POSSIBLE.

4. OCCUPANCY SENSOR SHALL BE PROVIDED WITH AUXILIARY RELAY FOR CONNECTION TO HVAC

CONTROL SYSTEM AND SHALL BE UL916 LISTED FOR ENERGY MANAGEMENT.

5. ALL WIRING CONCEALED WITHIN WALLS OR ABOVE HARD-LID CEILING SHALL BE ROUTED WITHIN

RACEWAY.

6. ALL WIRED CONTROL SHALL BE VIA LINE VOLTAGE.

DETAIL NOTES

TO

HVAC

O V

ER

R

ID

E

OVERRIDE

COMMON

LINE

VOLTAGE

SWITCH

LIGHTING

CIRCUIT

CLNG./WALL

SENSOR

TO

HVAC

(NOTE 4)

(NOTE 4)

GENERAL NOTES:

1. MAINTAIN A MINIMUM CLEARANCE OF 305mm (12") ON ALL SIDES OF ROOF PENETRATION

FROM WALLS, CURBS, AND OTHER PROJECTIONS TO FACILITATE PROPER FLASHING.

2. FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT OR OVERLAPPED.

3. VERIFY ROOF & STRUCTURAL SYSTEM WITH ARCHITECT.

4. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR TO ENSURE PROPER

METHODS & MATERIALS ARE USED TO MAINTAIN ROOF WARRANTY.

PREFABRICATED RUBBER BOOT CAP WITH

GRADUATED STEPS & WEATHER-PROOF

PRESSURE SEAL TO COLLAR

SEALANT AT PENETRATION TO

MEMBRANE JUNCTURE BY

ROOFING CONTRACTOR

MULTIPLE MEMBRANE STRIPPING PLIES FEATHERED

AT FIELD OF ROOF BY ROOFING CONTRACTOR.

PRIME FLANGE BEFORE STRIPPING.

PREFABRICATED FORMED 1.52mm

(0.06") THICK ALUMINUM FLASHING

ROUND COLLAR WITH MIN. 76mm (3")

WIDE FLANGE. ATTACH TO ROOF PER

MANUFACTURER'S INSTRUCTIONS

CONDUIT CLAMP. SIZE

AS REQUIRED

BATT INSULATION

ROOF MEMBRANE

WATER CUT-OFF MASTIC

COMPATIBLE WITH ROOF MEMBRANE

STAINLESS CLAMP, TYP.

9.52mm (3/8") MIN

GALVANIZED

THREADED ROD, TYP.

ROOF

STEEL EXPANSION

ANCHOR

INTEGRAL GALVANIZED

LIPPED STEEL

MOUNTING CHANNEL

CONDUIT, TYP.

CONDUIT

CLAMP.

SIZE AS

REQUIRED

LOCKING

SQUARE

WASHER &

LOCKNUT

TIE FIXTURE

WHIPS TO

STRUCTURE

SEALANT, TYP

TS

QTY=2

SCALE: NTS1 TYPICAL POLE BASE ASSEMBLY SCALE: NTS2 TYPICAL RECESSED LIGHTING INSTALLATION

SCALE: NTS3 TYPICAL FIRE ALARM RISER DIAGRAM

SCALE: NTS4 TYPICAL COMMUNICATIONS RISER DIAGRAM

SCALE: NTS5

SCALE: NTS6 CONDUIT ROOF PENETRATION DETAIL

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

LRL / BJR JPS / FEB

PIV

PROVIDE

POWER PACKS

AS REQUIRED

PROVIDE

3-WAY/4-WAY

SWITCHING

AS

REQUIRED/

INDICATED

LINE VOLTAGE OCCUPANCY/VACANCY SENSOR

SCHEMATIC

ELECTRICAL DETAILS

E-503

3.

5"

4"

6" M

A X

REFERENCE PLANS

FOR QUANTITY AND

SIZE OF CONDUITS

TOP VIEW

FRONT VIEW

HIGH VOLTAGE SIDE LOW VOLTAGE SIDE

FRONT VIEW

TOP VIEW

SIDE VIEW

CAT 6A FLAT PANEL, TYP

DATA BANK

SEE DETAIL NOTE #2

S

EE

D

ET

A

IL

N O

TE

SEE DETAIL

NOTE #2

1. COORDINATE FINAL DATA RACK LAYOUT WITH VA PRIOR TO ORDERING AND INSTALLATION.

2. REFERENCE SPECIFICATION 271100 FOR DIMENSIONAL REQUIREMENTS.

DETAIL NOTES

GROUND

GROUND SLEEVE

VA SWITCH

VA SWITCH

VA SWITCH

2RU UPS

2RU UPS

PROVIDE (8) 1 RU BLANK FACE PLATES

PROVIDED AND INSTALLED BY VA.

ETHERNET SWITCHES PROVIDED AND

INSTALLED BY VA.

LEVITON CONNECTORS

CABLE MANAGEMENT DUCT

CAST IN PLACE CONCRETE PAD.

72"

60"

1 RU BLANK FACE PLATE

1 RU BLANK FACE PLATE

1 RU BLANK FACE PLATE

1 RU BLANK FACE PLATE

1 RU BLANK FACE PLATE

1 RU BLANK FACE PLATE

1 RU BLANK FACE PLATE

1 RU BLANK FACE PLATE

1. TOP VIEW DETAIL SHOWN FOR BOTH TRANSFORMER "T34N"

AND "T34E". CONCRETE PAD SHALL EXTEND 12" FROM ALL

SIDES OF TRANSFORMER UNLESS SHOWN OTHERWISE.

DETAIL NOTES

TRANSFORMER

"T34E"

TRANSFORMER

"T34N"

SCALE: NTS1 TYPICAL OIL FILLED TRANSFORMER PAD MOUNT DETAIL

SCALE: NTS2 DATA RACK ASSEMBLY

PhaseARCHITECT/ENGINEER OF RECORD

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Revisions: Date:

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

07/23/2021

BOISE VA MEDICAL CENTER - BOISE, ID

531-325 A/E:

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590 - 2118

RAY SPEES, PRESIDENT

Approved:

Approved: CHIEF, FACILITY MANAGEMENT SERVICE

LRL / BJR JPS / FEB 194 OF 206

File details come from the government source that posted it. Updated .