531-325 - Drawings-02-C1.pdf

PDF 8 MB Posted

Attached to
Y1DZ--TIERED EVALS - Construct Primary Care/Mental Health Building Minor Construction - Boise 531-325
Solicitation number
36C77624R0096
Issued by

About this file

This document appears to be a set of civil engineering design drawings for a construction project for a Primary Care/Mental Health Building at the Boise VA Medical Center. The drawings provide details on the site demolition, utility work, grading, and stormwater management for the new building. Key details include:

The project involves constructing a new Primary Care/Mental Health Building at the Boise VA Medical Center. The civil engineering drawings cover the site demolition, utilities (water, sewer, geothermal, fire service), grading, and stormwater drainage for the new building. The drawings provide plan and profile views, construction details, and technical notes. The project is being managed by the Department of Veterans Affairs Technology Acquisition Center in Austin. The solicitation number is 36C77624R0096, with the project ID of 531-325. No additional information is provided about the solicitation, contract terms, or anticipated award.

View the file

Other files

File Type Posted
0005 - Tech Questions Tracker - Boise PCMH - 8-7-24.pdf PDF
36C77624R0096 0005.pdf PDF
36C77624R0096 0004.pdf PDF
0004 - Tech Questions Tracker - Boise PCMH - 8-5-24.pdf PDF
0004 - Brand Name Justification.pdf PDF
36C77624R0096 0003.pdf PDF
0003 - Tech Questions Tracker - Boise PCMH - 8-1-24.pdf PDF
36C77624R0096 0002.pdf PDF
0001 - Site Visit Sign-in - 7-16-24.pdf PDF
36C77624R0096 0001.pdf PDF
531-325 - Drawings-14-E3.pdf PDF
531-325 - Drawings-07-A2.pdf PDF
531-325 - SOW 4-15-24.pdf PDF
531-325 - Drawings-05-S1.pdf PDF
531-325 - Specs-Vol-1.pdf PDF
Small Business Subcontracting Plan Model.docx DOCX document
531-325 - Drawings-09-A4.pdf PDF
531-325 - Drawings-03-C2.pdf PDF
Division Cost Breakdown.xlsx XLSX spreadsheet
531-325 - Drawings-15-E4.pdf PDF
Limitations on Subcontracting - Construction.docx DOCX document
Site Visit Instructions.pdf PDF
531-325 - Drawings-16-E5.pdf PDF
531-325 - Specs-Appx-B.pdf PDF
531-325 - Drawings-04-L1.pdf PDF
531-325 - Specs-Vol-2.pdf PDF
531-325 - Drawings-10-M1.pdf PDF
531-325 - Specs-Appx-A.pdf PDF
Site Visit Map.pdf PDF
531-325 - Drawings-01-G1.pdf PDF
RFP 36C77624R0096.docx DOCX document
531-325 - Drawings-06-A1.pdf PDF
531-325 - Drawings-11-P1.pdf PDF
531-325 - Drawings-13-E2.pdf PDF
531-325 - Drawings-08-A3.pdf PDF
531-325 - Specs-Appx-C.pdf PDF
531-325 - Specs-Appx-E.pdf PDF
DBA Wage Rates - Ada County - 01-12-24.pdf PDF
531-325 - Drawings-12-E1.pdf PDF
531-325 - Specs-Appx-F.pdf PDF
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

E

BM-#1

UBX

W

W

SD SD SD

SS SS

GEO GEO

FIRE FIRE

W W W

E E E

T T T

BM

BM

BM

1 2 3 4 A

B

C

D

E

F

G

H

I

J

K L

M

N

3.9

L.2

A.10

2.1 2.91.1

10+00 11+00 12+00 13+00 14+00 15+00

STA. 13+48.28, 1.97' LT

BENCHMARK #2 (TEST POINT)

FOUND MAG NAIL

N:712562.09 E:2507823.15

EL:2726.93

STA. 10+00.00, 0.00' LT

BENCHMARK #1

FOUND MAG SPIKE

N:712885.38 E:2507693.57

EL:2725.07

S 21°31'05" E

N VA HOSPITAL LOOP

PROPOSED

BUILDING

STA. 11+01.90, 26.27' RT

GRID INTERSECTION A-1

S21°31'05"E

GRID A BEARING

R

Call 811 two business days before you dig

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

BOISE VA MEDICAL CENTER - BOISE, ID

531-325

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590-2118 RAY SPEES, PRESIDENT Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

07/23/2021 DC/CM

Revisions: Date:

JCG

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

ADA AMERICANS WITH DISABILITIES ACT OF 1990

ADS ADVANCED DRAINAGE SYSTEMS

APPROX APPROXIMATELY

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

BC BOTTOM OF CURB

CONC CONCRETE

CONT CONTRACTION

DIA DIAMETER

E EAST

EL ELEVATION

EX EXISTING

FDC FIRE DEPARTMENT CONNECTION

FFE FINISHED FLOOR ELEVATION

FT FEET

IE INVERT ELEVATION

LF LINEAR FEET

MAX MAXIMUM

MEP MECHANICAL ENGINEERING AND PLUMBING

MFR MANUFACTURER

MIN MINIMUM

N NORTH

NTS NOT TO SCALE

OZ OUNCES

PE POLYETHYLENE

PERF PERFORATED

PIV POST-INDICATOR VALVE

POC POINT OF CONNECTION

PVC POLYVINYL CHLORIDE

REINF REINFORCEMENT

S SOUTH

SDCO STORM DRAIN CLEAN-OUT

SQ SQUARE

STL STEEL

TC TOP OF CURB

TESC TEMPORARY EROSION AND SEDIMENT CONTROL

TYP TYPICAL

VA UNITED STATES DEPARTMENT OF VETERANS'

AFFAIRS

W WEST

YD YARD

NAVD 88 (GEOID18)

NAD 83 (2011)

FIRE HYDRANT

WATER OR STEAM VALVE

WATER BLOW-OFF

POST INDICATOR VALVE

SANITARY SEWER MANHOLE

SANITARY SEWER CLEAN-OUT

STORM DRAIN DROP INLET

SAND & GREASE TRAPS

STREET LIGHT

ELECTRICAL MANHOLE

ELECTRICAL JUNCTION BOX

ELECTRICAL GROUNDING ROD

IRRIGATION BOX/VALVES

SIGN

PROJECT BENCHMARK

CONIFEROUS TREE

DECIDUOUS TREE

STORM DRAIN LINE

SANITARY SEWER LINE

GEOTHERMAL LINE

FIRE LINE

WATER LINE

ELECTRICAL LINE

COMMUNICATION LINE

ROAD CROWN/CENTERLINE

CURB & GUTTER

SIDEWALK

C-100

CIVIL COVER SHEET

LOCATED IN SW 14 OF SECTION 02, TOWNSHIP 3 NORTH, RANGE 2

EAST, B.M., CITY OF BOISE, ADA COUNTY, IDAHO

# 1 - MAG SPIKE

NORTHING: 712885.38

EASTING: 2507693.57

EL: 2725.07

#2 - MAG NAIL

NORTHING: 712562.09

EASTING: 2507823.15

EL: 2726.93

#4 - MAG SPIKE

NORTHING: 712156.40

EASTING: 2507434.00

EL: 2726.39

#5 - BRASS CAP

NORTHING: 712713.54

EASTING: 2507465.30

EL: 2724.86

#6 - BRASS CAP

NORTHING: 712632.83

EASTING: 2507405.76

EL: 2724.56

CONSTRUCTION BASELINE EQUATION

SCALE 1" = 50'

1. CONSTRUCTION BASELINE IS DEFINED AS A LINE BEARING

S21°31'05"E THROUGH BENCHMARK #1.

2. PRIOR TO COMMENCING WORK, LOCATE ALL HORIZONTAL

CONTROL TEST POINTS FROM THE CONSTRUCTION

BASELINE. IF TEST POINTS ARE NOT AT STATION/OFFSET

SHOWN, CONTACT ENGINEER OF RECORD IMMEDIATELY.

CONSTRUCTION SHALL NOT PROCEED UNTIL THE

CONSTRUCTION BASELINE AND HORIZONTAL CONTROL TEST

POINTS HAVE BEEN LOCATED AS SHOWN.

3. BUILDING GRID LAYOUT IS PER THE ARCHITECT.

NORTH

BM

BM

BM

BM

T

T

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E

E

E

E

E E

E

E

E

E

E E

E

E

E

E E

E

E

E

E

E

E

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

E E

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

W

W

W

W W

W W

W W

W W

W

W

W W

W W

W

W

W

W

W

W

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

G

EO

G

EO

SS

TT

T

T

T

W

W

E

E

E

E

E

E

E

E

E

E

SD

SD

SD

W

W

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

W W

W

W

W

W

W

W

E

E

E E

E

E

T11

SEWER MANHOLE

RIM: 2728.22

INV. IN (SE):-6.85

INV. IN (NE):-6.89

INV.OUT (NW):-6.90

SEWER MANHOLE

RIM: 2726.71

INV. IN (SE):-7.17 - 8"

INV. IN (NE):-7.19 - 8"

INV.OUT (NW):-7.20 - 8"

SEWER MANHOLE

RIM: 2724.73

INV. IN (SE):-9.14 - 8"

INV.OUT (E):-9.15 - 8"

STORM DRAIN MANHOLE

RIM: 2724.58

INV. IN (NE):-3.81 - 12"

INV.OUT (SW):-3.81 - 12"

INLET

GRATE: 2723.92

INV.OUT (SE):-1.85

INLET

GRATE: 2724.31

INV.OUT (SE):-2.14

S&G TRAP

RIM (NE): 2724.18

INV.IN(NW&SE) -3.81 - 12"

RIM (SW): 2724.25

INV.OUT (SW):-4.10 - 12"

INLET

GRATE: 2723.79

INV.OUT (SE):-2.60

S&G TRAP

RIM (NE): 2724.75

UNABLE TO MEASURE

RIM (SW): 2724.68

UNABLE TO MEASURE

INLET

GRATE: 2723.74

INV.IN & OUT:-2.30 - 12"

S&G TRAP

RIM (NE): 2724.41

INV.IN(NW) -3.75 - 12"

RIM (SW): 2724.36

INV.OUT (NW):-4.05 - 12"

BENCH MARK #6

N: 712632.83

E: 2507405.76

EL: 2724.56

BRASS CAP

BENCH MARK #5

N: 712713.54

E: 2507465.30

EL: 2724.86

BRASS CAP

BENCH MARK #1

N: 712885.38

E: 2507693.57

EL: 2725.07

MAG SPIKE

BENCH MARK #2

N: 712562.09 E: 2507823.15

EL: 2726.93

MAG NAIL

PRESSURE

IRRIGATION

CONTROLS

BENCH

UTILITY DUCT BANK

DEPTH UNKNOWN.

SEE NOTE 3.

POWER TO

SPRINKLER

CONTROL BOX

IN MEMORY STONE

ROOF

DRAINS

POSSIBLE GEOTHERMAL

STUBS EXTRACTION /

INJECTION 2" LINES

PER RECORD DWGS

UNKNOWN

VALVE

DRAIN FIELD PER

RECORD DWGS

POSSIBLE WATER STUB

PER RECORD DWGS

GEOTHERMAL STUBS

SEWER

STUBS

3.2' VAULT MANHOLE

RIM: 2726.03

8'X10' VAULT

6" WATER LINE

6" WATER LINE

GRASS AREA

GRASS AREA

RAMP

G R

AS

S

AR

EA

PA

R

KI

N

G

G R

AS

S

AR

EA

AS

PH

AL

T

ASPHALT

TEMPORARY ORANGE

PLASTIC CONSTRUCTION

FENCE (TYP)

FILTER FABRIC

SILT FENCE

CATCH BASIN/INLET

PROTECTION (TYP)

CG210

CG210

CG210

N O

RTH

VA H

O

SPITAL LO

O

P RO

AD

TEMPORARY STABILIZED

CONSTRUCTION ENTRANCE

APPROXIMATE

LIMITS OF WORK

TEMPORARY

CONSTRUCTION FENCE

ENTRANCE GATE

PROPOSED BUILDING

REFER TO DETAIL 1 ON THIS SHEET FOR

GEOGRID REINFORCING AND REQUIRED

OVEREXCAVATION FOR FOOTINGS

CG200

2'2'

6" TY

P

1.

5'

FOOTING PER STRUCTURAL

SLAB ON GRADE BY

STRUCTURAL

STRUCTURAL FILL (ISPWC TYPE

1 CRUSHED AGGREGATE BASE)

COMPACTED TO 95% OF THE

MAXIMUM DRY DENSITY AS

DETERMINED BY ASTM D1557

NATIVE COMPACTED

SUBGRADE

TENSAR TX160

GEOGRID

NOTES:

1. GEOGRID REINFORCING SHALL BE PLACED UNDER ALL BUILDING FOOTINGS AS REQUIRED

BY THE GEOTECHNICAL ENGINEER.

2. GEOGRID SHALL EXTEND A MINIMUM 2-FEET BEYOND THE FOOTING ON ALL SIDES.

3. GEOGRID SHALL BE OVERLAPPED A MINIMUM DISTANCE OF 2-FEET BETWEEN SPLICES.

4. REFER TO STRUCTURAL PLANS FOR SLAB ON GRADE AND CAPILLARY BREAK INFORMATION.

GEOGRID REINFORCING UNDER FOOTINGS

SCALE: 1" = 2'

CG200

R

Call 811 two business days before you dig

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

BOISE VA MEDICAL CENTER - BOISE, ID

531-325

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590-2118 RAY SPEES, PRESIDENT Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

07/23/2021 DC/CM

Revisions: Date:

JCG

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

1 inch = 20 feet

10 20 40

1. THE EROSION AND SEDIMENT CONTROL FACILITIES SHOWN

ON THIS PLAN ARE THE MINIMUM REQUIREMENTS FOR

ANTICIPATED SITE CONDITIONS. DURING THE

CONSTRUCTION PERIOD, THESE FACILITIES SHALL BE

UPGRADED (E.G. ADDITIONAL PUMPS, RELOCATION OR

ADDITION OF DITCHES, SILT FENCES, ETC.) BY THE

CONTRACTOR AS NEEDED FOR UNEXPECTED STORM EVENTS

AT NO ADDITIONAL COST TO THE VA.

2. MONITOR DISCHARGE FLOW AND WATER QUALITY OF

DISCHARGE INTO STORM DRAIN. INCLUDE SAND FILTERS AS

REQUIRED, TO MEET THE VA TURBIDITY DISCHARGE

REQUIREMENTS.

3. ALL EROSION AND SEDIMENT CONTROL FACILITIES SHOWN

ON THIS PLAN MUST BE CONSTRUCTED IN CONJUNCTION

WITH ALL CLEARING, GRADING, AND EXCAVATION

ACTIVITIES IN SUCH A MANNER AS TO INSURE THAT

SEDIMENT LADEN WATER DOES NOT LEAVE THE SITE.

4. ALL EROSION AND SEDIMENT CONTROL FACILITIES SHALL

BE INSPECTED DAILY BY A CERTIFIED EROSION CONTROL

LEAD, AND MAINTAINED AS NECESSARY OR AS DIRECTED BY

THE VA TO ENSURE THEIR CONTINUED FUNCTIONING.

5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE

INSTALLED AT THE BEGINNING OF CONSTRUCTION AND

MAINTAINED UNTIL NO LONGER NECESSARY. ADDITIONAL

MEASURES MAY BE REQUIRED TO INSURE THAT ALL PAVED

AREAS ARE KEPT CLEAN FOR THE DURATION OF THE

PROJECT.

6. PROVIDE CONSTRUCTION FENCING AS REQUIRED FOR

SAFETY AND AS DIRECTED BY THE COR.

7. NO SEDIMENT SHALL BE TRACKED ONTO PAVED STREETS OR

ROADWAYS. THE CONTRACTOR SHALL EMPLOY EMERGENCY

MEASURES TO REMOVE SEDIMENT FROM PAVED SURFACES,

AS NEEDED. SEDIMENT TRACKED ONTO PAVED SURFACES

SHALL NOT BE WASHED INTO STORM DRAINS OR OTHER

UTILITY INLETS.

8. PROVIDE INLET PROTECTION TO ALL DOWNSTREAM INLETS

AND CATCH BASINS WITHIN 500 FEET OF THE JOB SITE.

9. MAINTAIN INLET PROTECTION FOR ALL ON-SITE INLETS

UNTIL CONNECTED STORM DRAIN INFRASTRUCTURE IS

FULLY DEMOLISHED AND DISCONNECTED FROM THE SYSTEM.

10. UPON FINAL COMPLETION OF THE PROJECT, ALL EROSION

AND SEDIMENT CONTROL FACILITIES SHALL BE REMOVED BY

THE CONTRACTOR. CARE SHALL BE TAKEN TO AVOID

SEDIMENT FROM ENTERING THE DRAINAGE SYSTEM DURING

THE REMOVAL PROCESS.

11. CONTRACTOR MUST TAKE CARE TO PROTECT THE

SURROUNDING ENVIRONMENT DURING THE CONSTRUCTION

PROCESS.

LEGEND

TESC NOTES

CG200

NORTH

APPROXIMATE LIMITS OF WORK

FILTER FABRIC SILT FENCE

TEMPORARY ORANGE PLASTIC

CONSTRUCTION FENCE

CATCH BASIN/INLET

PROTECTION

TEMPORARY STABILIZED

CONSTRUCTION ENTRANCE

TEMPORARY CONSTRUCTION

FENCE ENTRANCE GATE

TEMPORARY EROSION AND

SEDIMENT CONTROL PLAN

EXCEPT MAY BE REDUCED TO

50' MIN FOR SITES WITH LESS THAN

4" TO 8" QUARRY SPALLS

EXISTING ROAD R=25'

INGRESS / E

GRESS AREA

15' M

IN

PROVIDE FU

LL

WIDTH OF

M

IN

AS REQUIRED 100' MIN

ONE ACRE OF EXPOSED SOIL

TYPICAL CROSS SECTION

3'2' M

IN

2"X2"X14 GAUGE WIRE

FABRIC, OR

EQUIVALENT, IF

STANDARD STRENGTH

FABRIC USED

BACKFILL TRENCH WITH

NATIVE SOIL MATERIAL OR

3/4" TO 1-1/2" WASHED

GRAVEL.

NEWLY GRADED

OR DISTURBED

SOILS

MIN 4"X4" TRENCH

BURY BOTTOM OF FILTER

FABRIC MATERIAL WITH

EXCAVATED MATERIAL

2"X4" WOOD POSTS, STEEL

FENCE POSTS, REBAR, OR

EQUIVALENT.

6' MAX SPACING

EXISTING GRADE OR

UNDISTURBED SOILS

12"

MIN

PROJECT SITE

ORANGE PLASTIC

CONSTRUCTION FENCE

FILTER FABRIC

FILTER FABRIC SILT FENCE

NTS

CG210

TEMPORARY STABILIZED CONSTRUCTION ENTRANCE

NTS

CG210

CATCH BASIN/INLET PROTECTION

NTS

CG210

R

Call 811 two business days before you dig

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

BOISE VA MEDICAL CENTER - BOISE, ID

531-325

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590-2118 RAY SPEES, PRESIDENT Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

07/23/2021 DC/CM

Revisions: Date:

JCG

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

CG210

TEMPORARY EROSION AND

SEDIMENT CONTROL DETAILS

BM

BM

BM

T

T

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E

E

E

E

E E

E

E

E

E

E E

E

E

E

E E

E

E

E

E

E

E

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

E E

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

W

W

W

W W

W W

W W

W W

W

W

W W

W W

W

W

W

W

W

W

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

G

EO

G

EO

SS

TT

T

T

T

W

W

E

E

E

E

E

E

E

E

E

E

SD

SD

SD

W

W

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

W W

W

W

W

W

W

W

E

E

E E

E

E

T11

SEWER MANHOLE

RIM: 2728.22

INV. IN (SE):-6.85

INV. IN (NE):-6.89

INV.OUT (NW):-6.90

SEWER MANHOLE

RIM: 2726.71

INV. IN (SE):-7.17 - 8"

INV. IN (NE):-7.19 - 8"

INV.OUT (NW):-7.20 - 8"

SEWER MANHOLE

RIM: 2724.73

INV. IN (SE):-9.14 - 8"

INV.OUT (E):-9.15 - 8"

STORM DRAIN MANHOLE

RIM: 2724.58

INV. IN (NE):-3.81 - 12"

INV.OUT (SW):-3.81 - 12"

INLET

GRATE: 2723.92

INV.OUT (SE):-1.85

INLET

GRATE: 2724.31

INV.OUT (SE):-2.14

S&G TRAP

RIM (NE): 2724.18

INV.IN(NW&SE) -3.81 - 12"

RIM (SW): 2724.25

INV.OUT (SW):-4.10 - 12"

INLET

GRATE: 2723.79

INV.OUT (SE):-2.60

S&G TRAP

RIM (NE): 2724.75

UNABLE TO MEASURE

RIM (SW): 2724.68

UNABLE TO MEASURE

INLET

GRATE: 2723.74

INV.IN & OUT:-2.30 - 12"

S&G TRAP

RIM (NE): 2724.41

INV.IN(NW) -3.75 - 12"

RIM (SW): 2724.36

INV.OUT (NW):-4.05 - 12"

BENCH MARK #6

N: 712632.83

E: 2507405.76

EL: 2724.56

BRASS CAP

BENCH MARK #5

N: 712713.54

E: 2507465.30

EL: 2724.86

BRASS CAP

BENCH MARK #1

N: 712885.38

E: 2507693.57

EL: 2725.07

MAG SPIKE

BENCH MARK #2

N: 712562.09 E: 2507823.15

EL: 2726.93

MAG NAIL

PRESSURE

IRRIGATION

CONTROLS

BENCH

UTILITY DUCT BANK

DEPTH UNKNOWN.

SEE NOTE 3.

POWER TO

SPRINKLER

CONTROL BOX

IN MEMORY STONE

ROOF

DRAINS

POSSIBLE GEOTHERMAL

STUBS EXTRACTION /

INJECTION 2" LINES

PER RECORD DWGS

UNKNOWN

VALVE

DRAIN FIELD PER

RECORD DWGS

POSSIBLE WATER STUB

PER RECORD DWGS

GEOTHERMAL STUBS

SEWER

STUBS

3.2' VAULT MANHOLE

RIM: 2726.03

8'X10' VAULT

6" WATER LINE

6" WATER LINE

POWER BOX

GRASS AREA

GRASS AREA

RAMP

G R

AS

S

AR

EA

PA

R

KI

N

G

G R

AS

S

AR

EA

AS

PH

AL

T

ASPHALT

N O

RTH

VA H

O

SPITAL LO

O

P RO

AD

REMOVE EXISTING

TREE (TYP)

PROPOSED BUILDING

APPROXIMATE

LIMITS OF WORK

EX MEMORY STONE

SEE NOTE 11.

R

Call 811 two business days before you dig

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

BOISE VA MEDICAL CENTER - BOISE, ID

531-325

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590-2118 RAY SPEES, PRESIDENT Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

07/23/2021 DC/CM

Revisions: Date:

JCG

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

1. SEE SHEET C-100 FOR ABBREVIATIONS AND LEGEND.

2. PROTECT IN PLACE ALL UNDERGROUND UTILITIES AND

ASSOCIATED STRUCTURES WITHIN THE LIMIT OF WORK

UNLESS NOTED OTHERWISE.

3. DEMOLISH ALL EXISTING SURFACE FEATURES WITHIN THE

LIMIT OF WORK UNLESS NOTED OTHERWISE

4. PROTECT IN PLACE ALL UTILITIES AND SURFACE FEATURES

OUTSIDE THE LIMIT OF WORK.

5. CONTRACTOR SHALL WALK THE SITE WITH THE COR PRIOR

TO CONSTRUCTION TO VERIFY LIMITS OF SITE

DISTURBANCE AND EXISTING FEATURES, UTILITIES, AND

STRUCTURES TO BE PROTECTED.

6. MAKE VERTICAL SAWCUTS BETWEEN EXISTING PAVEMENT

TO REMAIN AND PAVEMENT TO BE REMOVED. PROTECT IN

PLACE PAVEMENT OUTSIDE SAWCUT LINE.

7. PROVIDE CONSTRUCTION FENCING, SIGNAGE, AND

BARRIERS AS REQUIRED TO PREVENT UNAUTHORIZED

ACCESS INTO THE DEMOLITION AREA.

8. REFER TO ELECTRICAL PLANS FOR INFORMATION ON

REMOVAL OF EXISTING ELECTRICAL INFRASTRUCTURE.

9. CONTRACTOR SHALL REMOVE ALL DEMOLITION DEBRIS

FALLING OUTSIDE THE LIMIT OF WORK IMMEDIATELY.

10. CONTRACTOR SHALL DISPOSE OF ALL DEMOLITION

MATERIAL OFF-SITE IN A SAFE AND LEGAL MANNER AT NO

ADDITIONAL EXPENSE TO THE OWNER.

11. CONTRACTOR SHALL SALVAGE THE EXISTING MEMORY

STONE AND HAND IT OVER TO THE COR PRIOR TO

BEGINNING CONSTRUCTION.

12. A PRE-EXCAVATION MEETING IS REQUIRED WITH THE STATE

HISTORIC PRESERVATION OFFICE (SHPO) AND THE PROJECT

COR BEFORE ANY GROUND DISTURBANCE TAKES PLACE.

COORDINATE THE TIME AND LOCATION OF THE MEETING

WITH THE PROJECT COR AND LOCAL SHPO STAFF.

13. THE SHPO INADVERTENT DISCOVERY PLAN (IDP) PROTOCOLS

MUST BE FOLLOWED ON THIS PROJECT. REFERENCE PROJECT

SPECIFICATION APPENDICES FOR DETAILS OF IDP AND

COORDINATE WITH THE PROJECT COR.

SITE DEMOLITION NOTES

LEGEND

APPROXIMATE LIMITS OF WORK

SAWCUT LINE

REMOVE EXISTING TREE

PROTECT EXISTING SIDEWALK

FLAG NOTES

PROTECT CURB EAST AND WEST OF THE SAWCUT AREA

MARKED. SEE NOTE 6 ABOVE.

PROTECT EXISTING STREET LIGHT AND ANY ASSOCIATED

CONDUITS. REFER TO ES101 FOR STREET LIGHTING WORK.

REMOVE AND STORE SOLAR CROSSWALK LIGHTS.

RE-INSTALL AT PROJECT COMPLETION PER ELECTRICAL

PLANS.

PROTECT EXISTING SIDEWALK. MAINTAIN PEDESTRIAN

ACCESS IN THIS AREA THROUGHOUT CONSTRUCTION.

PROTECT EXISTING TREE.

RELOCATE EXISTING STREET LIGHT POLE AND BASE AND

EXTEND ANY ASSOCIATED CONDUITS PER ELECTRICAL PLAN

ES101.

1 inch = 20 feet

10 20 40

CD300

NORTH

SITE DEMOLITION PLAN

BM

BM

BM

T

T

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

E E

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

W

W

W

W W

W W

W W

W W

W

W

W W

W W

W

W

W

W

W

W

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

G

EO

G

EO

SS

TT

T

T

T

W

W

E

E

E

E

E

E

E

E

E

E

SD

SD

SD

W

W

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

W W

W

W

W

W

W

W

E

E

E E

E

E

T11

SEWER MANHOLE

RIM: 2728.22

INV. IN (SE):-6.85

INV. IN (NE):-6.89

INV.OUT (NW):-6.90

SEWER MANHOLE

RIM: 2726.71

INV. IN (SE):-7.17 - 8"

INV. IN (NE):-7.19 - 8"

INV.OUT (NW):-7.20 - 8"

SEWER MANHOLE

RIM: 2724.73

INV. IN (SE):-9.14 - 8"

INV.OUT (E):-9.15 - 8"

STORM DRAIN MANHOLE

RIM: 2724.58

INV. IN (NE):-3.81 - 12"

INV.OUT (SW):-3.81 - 12"

INLET

GRATE: 2723.92

INV.OUT (SE):-1.85

INLET

GRATE: 2724.31

INV.OUT (SE):-2.14

S&G TRAP

RIM (NE): 2724.18

INV.IN(NW&SE) -3.81 - 12"

RIM (SW): 2724.25

INV.OUT (SW):-4.10 - 12"

INLET

GRATE: 2723.79

INV.OUT (SE):-2.60

S&G TRAP

RIM (NE): 2724.75

UNABLE TO MEASURE

RIM (SW): 2724.68

UNABLE TO MEASURE

INLET

GRATE: 2723.74

INV.IN & OUT:-2.30 - 12"

S&G TRAP

RIM (NE): 2724.41

INV.IN(NW) -3.75 - 12"

RIM (SW): 2724.36

INV.OUT (NW):-4.05 - 12"

BENCH MARK #6

N: 712632.83

E: 2507405.76

EL: 2724.56

BRASS CAP

BENCH MARK #5

N: 712713.54

E: 2507465.30

EL: 2724.86

BRASS CAP

BENCH MARK #1

N: 712885.38

E: 2507693.57

EL: 2725.07

MAG SPIKE

BENCH MARK #2

N: 712562.09 E: 2507823.15

EL: 2726.93

MAG NAIL

PRESSURE

IRRIGATION

CONTROLS

UTILITY DUCT BANK

DEPTH UNKNOWN.

SEE NOTE 3.

POWER TO

SPRINKLER

CONTROL BOX

ROOF

DRAINS

UNKNOWN

VALVE

POSSIBLE WATER STUB

PER RECORD DWGS

GEOTHERMAL STUBS

ER

3.2' VAULT MANHOLE

RIM: 2726.03

8'X10' VAULT

6" WATER LINE

6" WATER LINE

POWER BOX

GRASS AREA

RAMP

G R

AS

S

AR

EA

PA

R

KI

N

G

G R

AS

S

AR

EA

AS

PH

AL

T

ASPHALT

MN

O

RTH

VA H

O

SPITAL LO

O

P RO

AD

FFE=2725.85

9+00

10+00

11+00

12+00

13+00

14+00

15+00

6' M

IN

(2) 2" DOMESTIC

WATER LINES IN

JOINT TRENCH

PROFILE

GEOTHERMAL

RETURN PROFILE

GEOTHERMAL

SUPPLY PROFILE

SANITARY

SEWER PROFILE

APPROXIMATE

LIMITS OF WORK

STA. 12+25.70, 19.72' LT

CONNECT TO EX. 6" WATER MAIN

(1) DOUBLE STRAP SERVICE SADDLE

(1) 2" GATE VALVE WITH ADJUSTABLE

VALVE BOX

STA. 12+19.29, 5.19' RT

CONNECT TO EX. 8"

GEOTHERMAL MAINS

STA. 12+18.46, 6.45' RT

CONNECT TO EX. 8"

GEOTHERMAL MAINS

(2) GATE VALVES

STA. 11+35.30, 17.37' RT

CONNECT TO EX. SANITARY

SEWER MANHOLE

STA. 10+78.17, 22.77' RT

90° HORZ BEND

RESTRAINED JOINT

THRUST BLOCK

FIRE SERVICE

PROFILE

STA. 10+78.71, 14.91' LT

CONNECT TO EX. 6"

FIRE/IRRIGATION MAIN

(1) 6"x6" TEE

(1) GATE VALVE

THRUST BLOCK

BUILDING MOUNTED

FDC. SEE PLUMBING.

STA. 10+95.39, 22.77' RT

POST-INDICATOR VALVE

STA. 11+35.33, 20.02' RT

SANITARY SEWER POC

SEE PLUMBING FOR

CONTINUATION

STA. 12+15.02, 23.28' RT

6" FIRE SERVICE POC

SEE PLUMBING FOR

CONTINUATION

STA. 12+18.46, 20.02' RT

3" GEOTHERMAL SUPPLY

& RETURN POC. SEE PLUMBING

FOR CONTINUATION

STA. 12+21.76, 19.91' RT

2" DOMESTIC WATER POC

SEE PLUMBING FOR CONTINUATION

STA. 12+15.03, 22.75' RT

90° HORZ BEND

RESTRAINED JOINT

THRUST BLOCK

STORMWATER DRAINAGE SYSTEM

SEE NOTE 9

PROPOSED TREE PER

LANDSCAPE (TYP)

STA. 12+23.70, 19.82' LT

CONNECT TO EX. 6" WATER MAIN

(1) DOUBLE STRAP SERVICE SADDLE

(1) 2" GATE VALVE WITH ADJUSTABLE

VALVE BOX

STA. 12+23.79, 20.06' RT

2" DOMESTIC WATER POC

SEE PLUMBING FOR CONTINUATION

EXISTING FIRE

HYDRANT TO REMAIN

EXISTING FIRE

HYDRANT TO REMAIN

115' FROM FDC

EXISTING FIRE

HYDRANT TO REMAIN

CU410

CU410

CU4104

CU410

CU410

R

Call 811 two business days before you dig

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

BOISE VA MEDICAL CENTER - BOISE, ID

531-325

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590-2118 RAY SPEES, PRESIDENT Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

07/23/2021 DC/CM

Revisions: Date:

JCG

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

1. FDC SHALL BE MOUNTED TO THE BUILDING. REFER TO FIRE

PROTECTION PLAN PF105 FOR INFORMATION.

2. DOMESTIC WATER AND FIRE PROTECTION BACKFLOW

PREVENTION IS LOCATED INSIDE THE BUILDING. REFER TO

PLUMBING PLANS FOR INFORMATION.

3. CONTRACTOR SHALL COORDINATE PROTECTION AND

ADJUSTMENT OF ALL UTILITIES AND UTILITY STRUCTURE

WITH THE COR.

4. CONTRACTOR SHALL VERIFY ALL EXISTING UTILITY DEPTHS

AND LOCATIONS PRIOR TO BEGINNING CONSTRUCTION

ACTIVITIES. POTHOLE ALL UTILITY CROSSINGS AT WATER

SERVICE AND FIRE SERVICE CROSSINGS A MINIMUM 2

WEEKS PRIOR TO INSTALLATION.

5. PRIOR TO ANY CONSTRUCTION ACTIVITIES, CONTRACTOR

SHALL LOCATE ALL WATER SHUT OFF VALVES AND VERIFY

THAT THE VALVES ARE IN WORKING ORDER. A WATER VALVE

MAP MUST BE GENERATED AND KEPT ON SITE THROUGHOUT

THE DURATION OF THE PROJECT.

6. CONTRACTOR SHALL ADJUST ALL EXISTING UTILITY

STRUCTURES TO REMAIN TO GRADE AT PROJECT

COMPLETION.

7. STATIONS, OFFSETS, AND DIMENSIONS SHOWN HEREIN ARE

TO THE CENTER OF UTILITY PIPES OR STRUCTURES UNLESS

NOTED OTHERWISE.

8. ELECTRICAL AND TELECOMMUNICATION LINEWORK SHOWN

HEREIN IS FOR REFERENCE ONLY. SEE ELECTRICAL PLANS.

9. REFER TO SHEET CG500 FOR INFORMATION ABOUT THE

STORMWATER DRAINAGE SYSTEM.

10. REFER TO SHEET CU410 FOR UTILITY PROFILES.

1 inch = 20 feet

10 20 40

UTILITY NOTES

LEGEND

APPROXIMATE LIMITS OF WORK

SANITARY SEWER LINE

DOMESTIC WATER LINE

FIRE SERVICE LINE

THRUST BLOCK & BEND

POST-INDICATOR VALVE (PIV)

GATE VALVE

CU400

NORTH

UTILITY PLAN

EX GRADE

FINISH GRADE

EX

S A N

IT

A R Y

S

EW

ER

IE

.6

CU410

DOMESTIC WATER PROFILE

SCALE: 1" = 5'

EX

G

EO

TH

ER

M

A L

S U

PP

LY

C O

N N

EC

T

TO

EX

W A

TE

R M

A

IN

EX

G

EO

TH

ER

M

A L

R

ET

U R N

EX

E

LE

C

TR

IC

A L

EX

FI

R E

M A

IN

EX

C

O N

D U

IT

B A N

K

3' C

O V

ER

M

IN

PROPOSED

BUILDING

W A

TE

R P

O C

S

EE

P

LU

M B

IN

G F

O R

C O

N

TI

N U

A

TI

O N

GATE VALVE

V

ER

TI

C A L

B

EN

D

V

ER

TI

C A L

B

EN

D

2 LF 2" DW

6 LF 2" DW

19 LF 2" DW

6 LF 2" DW

11 LF 2" DW

V

ER

TI

C A L

B

EN

D

V

ER

TI

C A L

B

EN

D

(2) 2" DOMESTIC WATER

LINES IN JOINT TRENCH

CU410

GEOTHERMAL RETURN PROFILE

SCALE: 1" = 5'

PROPOSED

BUILDING

C O

N N

EC

T

TO

EX

G

EO

TH

ER

M A L

R

ET

U R N

EX

G

EO

TH

ER

M

A L

S U

PP

LY

EX

S A N

IT

A R Y

S

EW

ER

IE

.6

EX GRADE

FINISH GRADE

G

EO

TH

ER

M A L

PO

C

S

EE

P

LU

M B

IN

G F

O R

C O

N

TI

N U

A

TI

O N

15 LF 3"

GATE VALVE

CU410

GEOTHERMAL SUPPLY PROFILE

SCALE: 1" = 5'

EX

S A N

IT

A R Y

S

EW

ER

IE

.7

C O

N N

EC

T

TO

EX

G

EO

TH

ER

M A L

S U

PP

LY

EX GRADE

FINISH GRADE

G

EO

TH

ER

M A L

PO

C

S

EE

P

LU

M B

IN

G F

O R

C O

N

TI

N U

A

TI

O N

PROPOSED

BUILDING

EX

G

EO

TH

ER

M

A L

R

ET

U R N

14 LF 3"

GATE VALVE

CU410

SANITARY SEWER PROFILE

SCALE: 1" = 5'

S

EW

ER

P

O C

S

EE

P

LU

M B

IN

G F

O R

C O

N

TI

N U

A

TI

O N

IE

.3

PROPOSED

BUILDING

(E X

EX

G

EO

TH

ER

M

A L

S U

PP

LY

EX GRADE

FINISH GRADE

(E X

NOTE : RAISE RIM

OF EXISTING

SANITARY SEWER

MANHOLE TO MATCH

FINISH GRADE.

6" FIRE SERVICE

C O

N N

C

ET

T O

E X S

S M

H

R

IM

.5

6"

I E

IN

.2

(W

8" I

E O

U T=

.0

(S

8" I

E O

U T=

.9

(N

6 LF 6" SS

@ 2.0%

CU410

FIRE PROFILE

SCALE: 1" = 5'

EX

W

A

TE

R M

A

IN

C O

N N

EC

T

TO

EX

FI

R E

M A

IN

H O

R Z O

N

TA

L B

EN

D

EX

E

LE

C

TR

IC

A L

EX

C

O N

D U

IT

B

A N

K

EX

G

EO

TH

ER

M

A L

R

ET

U R N

POST-INDICATOR

VALVE

EX

S A N

IT

A R Y

S

EW

ER

IE

.6

PROPOSED

BUILDING

6" S

S

IE

.5

H O

R Z O

N

TA

L B

EN

D

GATE VALVE

4 LF 6" FS

6 LF 6" FS

V

ER

TI

C A L

B

EN

D

R J)

(2

V

ER

TI

C A L

B

EN

D

R J)

6 LF 6" FS

14 LF 6" FS

9 LF 6" FS

137 LF 6" FS

EX COMM

EX

G

EO

TH

ER

M

A L

S U

PP

LY

(2

V

ER

TI

C A L

B

EN

D

R J)

EX GRADE

FINISH GRADE

R

Call 811 two business days before you dig

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

BOISE VA MEDICAL CENTER - BOISE, ID

531-325

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590-2118 RAY SPEES, PRESIDENT Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

07/23/2021 DC/CM

Revisions: Date:

JCG

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

CU410

1 inch = 20 ft. HORZ

10' 20' 40'

1 inch = 20 ft. VERT

10' 20' 40'

1. REFER TO MEP PLANS FOR PIPING, CONNECTION, AND

TRENCH INFORMATION FOR GEOTHERMAL RETURN LINE.

NOTES

1. REFER TO MEP PLANS FOR PIPING, CONNECTION, AND

TRENCH INFORMATION FOR GEOTHERMAL SUPPLY LINE.

NOTES

UTILITY PROFILES

M

2725 2725

N O

RTH

VA H

O

SPITAL LO

O

P RO

AD

FFE=2725.85

GRADING

ENLARGEMENT

CG530

GRADING

ENLARGEMENT

CG530

GRADING

ENLARGEMENT

CG530

CG520

LANDSCAPE DRAIN

STA. 12+30.49, 162.88' RT

SDCO #2

STORM DRAIN PROFILE

CG510

CG510

STA. 11+87.88, 279.96' RT

SDMH #5

STA. 12+51.23, 162.92' RT

SDMH #3

STA. 12+79.58, 185.92' RT

SDMH #4

84 x 50 x 4

SEEPAGE BED

STA. 12+30.59, 110.85' RT

SDCO #1

SDCO (TYP)

STA. 12+29.29, 110.85' RT

ROOF LEADER POC

SEE PLUMBING FOR

CONTINUATION

APPROXIMATE

LIMITS OF WORK

9+00

10+00

11+00

12+00

13+00

14+00

15+00

STA. 12+97.66, 255.95' RT

SEDIMENTATION TANK

STA. 12+38.48, 162.90' RT

END LANDSCAPE DRAIN

CG520

2724.99 (EX)

2724.98 (EX)

2726.06 (EX)

2726.01 (EX)

2727.83 (EX)

2727.85 (EX)

STA. 12+60.00, 246.62' RT

INLET CATCH BASIN TYPE 3

RIM=2724.81

IE=2722.31 (8" OUT, SW)

STA. 11+84.27, 265.33' RT

INLET CATCH BASIN TYPE 3

RIM=2724.91

IE=2722.41 (8" OUT, SW)

STA. 12+38.72, 30.68' RT

SDCO #3

RIM=2725.66

6" IE=2722.78 (IN)

6" IE=2722.78 (OUT)

CG521

STA. 12+70.94, 279.74' RT

GROUNDWATER

OBSERVATION WELL

CG520

STA. 11+01.87, 19.27' RT

SDCO #5

BEGIN LANDSCAPE DRAIN

RIM=2725.71

6" IE=2724.00 (OUT)

STA. 12+27.32, 19.28' RT

SDCO #4

RIM=2725.73

6" IE=2722.92 (IN)

6" IE=2722.92 (OUT)

CG521

2724.62

2724.53

2725.85

2725.85

STORM DRAIN PROFILE

125 LF 6" PERF SD @ 0.86%

16 LF 6" PERF SD @ 0.86%

LF

PE

RF

S

D

.8

6%

TYP

TYP

CG521 STA. 13+02.14, 274.04' RT

SDCO #6

CG520

BM

BM

BM

BM

T

T

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E

E

E

E

E E

E

E

E

E

E

E

E

E

E

E E

E

E

E

E

E

E

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

G

EO

E E

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

FIRE

W

W

W

W W

W W

W W

W W

W

W

W W

W W

W

W

W

W

W

W

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

GEO

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

G

EO

G

EO

SS

TT

T

T

T

W

W

E

E

E

E

E

E

E

E

E

E

SD

SD

SD

W

W

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

W W

W

W

W

W

W

W

E

E

E E

E

E

T11

SEWER MANHOLE

RIM: 2728.22

INV. IN (SE):-6.85

INV. IN (NE):-6.89

INV.OUT (NW):-6.90

SEWER MANHOLE

RIM: 2726.71

INV. IN (SE):-7.17 - 8"

INV. IN (NE):-7.19 - 8"

INV.OUT (NW):-7.20 - 8"

SEWER MANHOLE

RIM: 2724.73

INV. IN (SE):-9.14 - 8"

INV.OUT (E):-9.15 - 8"

STORM DRAIN MANHOLE

RIM: 2724.58

INV. IN (NE):-3.81 - 12"

INV.OUT (SW):-3.81 - 12"

INLET

GRATE: 2723.92

INV.OUT (SE):-1.85

INLET

GRATE: 2724.31

INV.OUT (SE):-2.14

S&G TRAP

RIM (NE): 2724.18

INV.IN(NW&SE) -3.81 - 12"

RIM (SW): 2724.25

INV.OUT (SW):-4.10 - 12"

INLET

GRATE: 2723.79

INV.OUT (SE):-2.60

S&G TRAP

RIM (NE): 2724.75

UNABLE TO MEASURE

RIM (SW): 2724.68

UNABLE TO MEASURE

INLET

GRATE: 2723.74

INV.IN & OUT:-2.30 - 12"

S&G TRAP

RIM (NE): 2724.41

INV.IN(NW) -3.75 - 12"

RIM (SW): 2724.36

INV.OUT (NW):-4.05 - 12"

BENCH MARK #6

N: 712632.83

E: 2507405.76

EL: 2724.56

BRASS CAP

BENCH MARK #5

N: 712713.54

E: 2507465.30

EL: 2724.86

BRASS CAP

BENCH MARK #1

N: 712885.38

E: 2507693.57

EL: 2725.07

MAG SPIKE

BENCH MARK #2

N: 712562.09 E: 2507823.15

EL: 2726.93

MAG NAIL

PRESSURE

IRRIGATION

CONTROLS

UTILITY DUCT BANK

DEPTH UNKNOWN.

SEE NOTE 3.

POWER TO

SPRINKLER

CONTROL BOX

ROOF

DRAINS

UNKNOWN

VALVE

POSSIBLE WATER STUB

PER RECORD DWGS

GEOTHERMAL STUBS

ER

3.2' VAULT MANHOLE

RIM: 2726.03

8'X10' VAULT

6" WATER LINE

6" WATER LINE

POWER BOX

GRASS AREA

RAMP

G R

AS

S

AR

EA

PA

R

KI

N

G

G R

AS

S

AR

EA

AS

PH

AL

T

ASPHALT

2727.55

2727.64

R

Call 811 two business days before you dig

1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

CONSTRUCT PRIMARY

CARE / MENTAL HEALTH

BUILDING

BOISE VA MEDICAL CENTER - BOISE, ID

531-325

SPEES DESIGN BUILD

625 1ST AVE #301

SEATTLE, WA, 98014

(206) 590-2118 RAY SPEES, PRESIDENT Approved: CHIEF, FACILITY MANAGEMENT SERVICE

MEDICAL CENTER DIRECTOR

07/23/2021 DC/CM

Revisions: Date:

JCG

P-17032

G F

I LA NS

E

E E

ORP R

O

E

S N

NI

N

M

A A

F.

R

IT CH

S E

FO

S

OTATE ADI

H

E DELI

C NS

1. CONTRACTOR SHALL FIELD VERIFY EXISTING LOCATION AND

INVERT ELEVATION OF STORM DRAIN POINT OF

CONNECTION AND NOTIFY ENGINEER IMMEDIATELY IF

DIFFERENT FROM PLANS.

2. ALL STORMWATER ELEMENTS INCLUDING PIPES, CATCH

BASINS, MANHOLES, AND WATER QUALITY FACILITIES WILL

BE MAINTAINED BY THE PROPERTY OWNER AFTER

COMPLETION OF THE PROJECT.

3. ALL DIMENSIONS, STATIONS, AND OFFSETS SHOWN FOR

UTILITY STRUCTURES ARE MEASURED TO THE CENTER OF

STRUCTURE, UNLESS NOTED OTHERWISE.

4. REFER TO SHEET CG510 FOR STORM DRAINAGE PROFILES.

5. REFER TO SHEET CU400 FOR SITE UTILITIES.

1 inch = 20 feet

10 20 40

GRADING AND STORM DRAINAGE NOTES

LEGEND

APPROXIMATE LIMITS OF WORK

GRADING ENLARGEMENT

GRADE BREAK

SPOT ELEVATION

STORM DRAIN < 12"

LANDSCAPE DRAIN

48" STANDARD CONCRETE

CATCH MANHOLE

INLET CATCH BASIN TYPE III

SDCO

GROUNDWATER

OBSERVATION WELL

CG500

XXXX

M

NORTH

GRADING AND STORM DRAINAGE PLAN