4.- Exhibit C4 - Solid Waste Audit Reports (1).pdf

PDF 54 KB Posted

Attached to
Laredo Texas Full Maintenance; Operations and Maintenance; Custodial, Grounds, and Related Services
Solicitation number
47PH0225R0006
Issued by

About this file

Exhibit C4 is a detailed guide for conducting a solid waste audit within a federal building, aimed at achieving a minimum 50 percent waste diversion and supporting sustainable building principles. The contractor is required to perform a comprehensive waste stream analysis by examining a representative 24-hour sample of non-hazardous solid waste from various building spaces, including tenant areas, lobbies, and break rooms. Using scales, the contractor must sort and weigh waste into specific categories: paper, cardboard, plastic, aluminum, glass, organic/compostable waste, and non-recyclable trash.

Following the waste composition analysis, the contractor must provide recommendations for increasing the building's waste diversion rate through cost-effective collection and disposal methods. The recommendations must include a list of acceptable and unacceptable recycling materials, the potential waste diversion rate, potential additions to the building's recycling and composting program based on local recycling markets, and a narrative assessment of current recycling bin quantities, placement, and signage with suggestions for improving communication to tenants and custodial staff. The document includes a sample waste composition analysis table showing percentages of different waste types, with organic/compostable waste representing the largest portion at 41.7% of the total waste stream.

View the file

Other files

File Type Posted
47PH0225R0006 Amendment 0003 SF30 0 OF 12.pdf PDF
47PH0225R0006 Amendment 0003 Specification Laredo Texas Full Maintenance Operations and Maintenance1 of 12.pdf PDF
47PH0225R0006 Amendment 0003 BL-1 Fire Extinguisher Report 9 of 12.xlsx XLSX spreadsheet
47PH0225R0006 Amendment 0003 - Notes by Gemini Pre-Proposal Meeting Laredo - 10 of 12.pdf PDF
47PH0225R0006 Amendment 0002 SF30 PDF Form 12 of 12.pdf PDF
47PH0225R0006 Amendment 0003 Attendees to the Pre-Proposal Walk Thru Laredo Texas Full Maintenance 2 of 12.pdf PDF
47PH0225R0006 Amendment 0003 PDF Form SF1449-21 Solicitation for Commercial Products 3 of 12.pdf PDF
47PH0225R0006 Amendment 0003 Excel Doc Figure L-1 Combined Management Plan 7 of 12.xlsx XLSX spreadsheet
47PH0225R0006 Attachment 2_ Wage Determination Laredo Texas 3 of 7.pdf PDF
47PH0225R0006 Amendment 0001 SF30 1 of 4.pdf PDF
5. Exhibit C5 - Building Information Sheet - Columbia Land Port Of Entry (1).pdf PDF
6. Exhibit C5 - Building Information Sheet - Covent Land Port Of Entry (1).pdf PDF
11.- Exhibit M1 - O_M QASP Template (2).pdf PDF
18.- Exhibit M8_ Miscellaneous Best Practices Shave Energy.pdf PDF
1.- Exhibit C1- Custodial R7 Recycling & Solid Waste Trash Report - APR24.pdf PDF
2.- Exhibit C-2 M1-FM Quality Assurance Surveillance Plan (1).pdf PDF
12.- Exhibit M2 - Green Purchasing Report (1) (1).pdf PDF
17.- Exhibit M7 - Electrical Testing Technicians Requisites.pdf PDF
20.- Exhibit M10 Final Refrigerant Management SOP 2022.pdf PDF
47PH0225R0006 Amendment 0001 FIGURE L-3 Experience Worksheet 3 of 4.pdf PDF
47PH0225R0006 Amendment 0001 Questions and Answers 4 of 4.pdf PDF
3.- Exhibit C3 - Pest Control Work and Inspection Report (1).pdf PDF
3.- Exhibit C3 - Pest Control Work and Inspection Report.pdf PDF
7. Exhibit C5 - Building Information Sheet - Juarez Lincoln Land Port of Entry.pdf PDF
11.- Exhibit M1 - O_M QASP Template (1).pdf PDF
19.- Exhibit M9 2022 GSA PBS PM Guide (1).pdf PDF
28.- BL1_ Extinguisher Report - List of Assets.pdf PDF
32.- BL6 Work Order History - List of Work Orders.pdf PDF
33.- BL7 Energy_&_Water_Monthly_Report_template.docx.pdf PDF
37.- Figure L-1 Combined Management Plan 7.18.24.xlsx XLSX spreadsheet
5. Exhibit C5 - Building Information Sheet - Columbia Land Port Of Entry.pdf PDF
9. Exhibit C5 - Building Information Sheet - Border Patrol Sector Headquarters.pdf PDF
10. Exhibit C5 - Building Information Sheet - George P. Kazen Federal Courthouse.pdf PDF
14.- Exhibit M4 Building Operating Plan Template.pdf PDF
21.- Exhibit M11_ Flag Policy.pdf PDF
22.- Exhibit M12_ Flushing Stagnant Plumbing.pdf PDF
23.- Exhibit M13 Sample Fuel Storage Tank Management Plan.pdf PDF
29.- BL2 Inventory to Include Fire Alarm Devices - List of Assets.pdf PDF
36.- Figure B-3 FM 5 Year Contract 10.30.24 .xlsx XLSX spreadsheet
38.- Figure L-2 Past Performance Reference Questionnaire.pdf PDF
Solicitation 47PH0225R0006 Laredo Texas Full Maintenance Operations and Maintenance Custodial Grounds and Related Services.pdf PDF
2.- Exhibit C-2 M1-FM Quality Assurance Surveillance Plan.pdf PDF
Building Information World Trade Land Port of Entry.pdf PDF
12.- Exhibit M2 - Green Purchasing Report (1).pdf PDF
20.- Exhibit M10 Final Refrigerant Management SOP 2022 (1).pdf PDF
24.- Exhibit M14_ Underground Fuel Storage Tank Inspection Requirements .pdf PDF
25.- Exhibit M15_ Above Ground Fuel Storage Tank Inspection Requirement.pdf PDF
31.- BL5 Roof Information - List of Assets.pdf PDF
34.- FIGURE B-1 for Union and Non Union FM Contracts.xlsx XLSX spreadsheet
39.- FIGURE L-3 Experience Worksheet.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXHIBIT C4: Solid Waste Audits

*This exhibit is provided to the Contractor as a guide to conduct a waste audit. The purpose of the waste audit is to:

• Identify cost-effective methods of achieving a minimum 50 percent (by weight) waste diversion.

• Support compliance with Guiding Principles for Sustainable Federal Buildings.

Extent of Work

Waste Composition The Contractor shall conduct a solid waste audit to identify the composition of the building’s non- hazardous, non-construction solid waste stream. As part of the solid waste stream audit, the Contractor shall examine a representative sample of solid waste (office trash) generated in the building (tenant space, lobby, kitchenettes/break rooms, printing rooms, bathrooms) during a 24-hour period of a typical workday. The Contractor shall use scales to weigh the sorted waste by the following material types: paper (all types of recyclable paper); cardboard;

plastic (#1 PET bottles and any recyclable plastics); aluminum/cans; glass bottles;

organic/compostable waste (food, food-related compostable packaging, paper towels); non-compostable, non-recyclable trash. The table below is provided as an example.

Table of Sample Waste Composition Analysis

Type of Waste Weight (lbs)

Percentage

Paper 50 16.7% Cardboard 25 8.3% Plastic 20 6.7% Aluminum 10 3.3% Glass 20 6.7% Organic / Compostable 125 41.7% Trash (not recyclable/compostable)

50 16.7%

Total 300 100%

Waste Diversion Recommendations Based on the waste composition analysis, the Contractor shall provide recommendations for increasing the building’s waste diversion rate through cost-effective. efficient waste collection and disposal. The recommendations shall include:

• A list of currently acceptable and unacceptable waste materials for recycling (to include recycling codes, such as PET 1, 2, etc.).

• The building’s potential waste diversion rate, based on the waste composition analysis.

• A list of waste material types that could be added to the building’s recycling (and composting) program, based on the local recycling market.

• A narrative description of the current recycling, composting, and trash bin quantities, placement, and signage, and recommendations for improving signage and communication to tenants and custodial employees.