RFP 438477 - Amendment No. 1 19JUL24.pdf

PDF 210 KB Posted

Attached to
EIC HSR BPM Button Assembly
Solicitation number
438477
Issued by

About this file

This document is Amendment No. 1 to Request for Proposal (RFP) No. 438477 for the design and fabrication of HSR BPM Button Assemblies for the Electron-Ion Collider (EIC) project. The amendment incorporates clarification questions and answers, extends the proposal due date to August 16, 2024, and specifies that the conical shape of the button design is required, but an alternative shape can be proposed if the cost difference is provided. The RFP is issued by the Department of Energy Office of Science and seeks up to three subcontractors to provide 35 preproduction components each, with an option for up to 1,355 production components. The RFP requires a leak rate of 2x10-10 cc He/sec and a button surface made of solid copper or copper-plated. The agency will exercise an option on one of the subcontracts for the production components.

View the file

Other files

File Type Posted
RFP 438477 - Amendment No. 7 12DEC24.pdf PDF
RFP 438477 - Amendment No. 6 22NOV24.pdf PDF
1. RFP 438477 - Amendment No. 5 07AUG24.pdf PDF
Attachment H - Changes to DWG 2551M0003 Rev 2 - 5.pdf PDF
Enclosure 3 - Proposal Pricing Page.pdf PDF
Attachment C - Technical Specification for the EIC HSR BPM Button Assembly.pdf PDF
Attachment G - EIC-VSG-SPC-023 Tech Spec Rev 0 04-18-2024.pdf PDF
Attachment B - SOW for the EIC HSR BPM Button Assembly.pdf PDF
Attachment D - DWG 2551m0003 Rev 5.pdf PDF
RFP 438477 - Amendment No. 4 07AUG24.pdf PDF
RFP 438477 - Amendment No. 3 05AUG24.pdf PDF
RFP 438477 - Amendment No. 2 26JUL24.pdf PDF
Attachment G - Specification for Fabrication and Cleaning CAD-1119.pdf PDF
1. Request for Proposal 438477.pdf PDF
2. Enclosure 1 - Draft Subcontract.pdf PDF
4. Enclosure 3 - Proposal Pricing Page.pdf PDF
Attachment E - BNL QA 101 Form - 438477.pdf PDF
3. Enclosure 2 - Annual Representations - Certifications.pdf PDF
Attachment B - SOW for the EIC HSR BPM Button Assembly.pdf PDF
Attachment G - Specification for Fabrication and Cleaning of CAD Vacuum Chamber Assemblies and Vacuum Components CAD-1119.pdf PDF
Attachment A - BSA_NonCommercial_Items_Rev22_Sep_2022.pdf PDF
Attachment C Technical Specification for the EIC HSR BPM Button Assembly Rev 2.pdf PDF
Attachment D - DWG 2551m0003 Rev 2 5-29-2024.pdf PDF
Attachment F - Patent Certification.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Property and Procurement Management Division

Building 1005S P.O. Box 5000

Upton, NY 11973-5000

Date: 07/19/2024

AMENDMENT NO. 1

to

Request for Proposal (RFP) No. 438477

For

HSR BPM Button Assembly

GENERAL: This Amendment No. 1 is to amend Request for Proposal RFP No. 438477 as follows.

1. Incorporate Attachment A – Clarification Question and Answer dated July 19, 2024, into RFP No. 438477 by reference.

2. Extend the proposal due date through August 16, 2024, 4:00PM EST.

All other terms, conditions, and provisions of this RFP shall remain unchanged.

Material, work, and workmanship, except where specified otherwise in this Amendment shall conform to all requirements of Contract Documents and become a part thereof.

Please confirm receipt of this Amendment No. 1 via email to the following.

Bill Koncelik wkoncelik@bnl.gov

(631) 344-5281 mailto:wkoncelik@bnl.gov

Attachment A

Clarification Questions and Answers

Dated July 19, 2024

1. Per Note 10 of drawing (Attachment D), exact dimensions of the conductor and housing bore is our option, as long as we form a 50 Ohm impedance line.

Question: Can we use existing design which is not a conical shape?

Answer: The conical shape behind the button face was developed to meet the requirements for this application. An alternative button shape behind the button face can be proposed, BNL would then need to do simulations to check if this is acceptable. If an alternative button shape is proposed, provide a mechanical drawing, and the cost difference between the BNL conical design and the alternative proposed design.

2. Your Requested leak rate is 2e-10 CC He/sec.

Question: Can this be reduced to 1e-8 ccHE/Sec which is industry standard rate?

Answer: 1e-8 leak checking is for HV applications not UHV. Our standard for UHV applications is 2x10-10.

3. 300 C bake temperature is too high for compression glass seal.

Question: Will it be possible for you to bake at 200 C for longer time?

Answer: Yes, 200C is ok.

4. Button surface on your drawing is copper plated.

Question: Can the plating be removed? Our standard BPM designs we currently have and been supplied to many labs are not plated.

Answer: A copper surface (or highly conductive metal) is required on the surfaces of the button to reduce the temperature increase of the button which is installed inside a cryostat operating at ~4 Kelvin. As the hadron beam passes close by the button, an induced current passed through the button face, if the button face surface (skin effect) material has an elevated resistance, elevated power will be deposited into the button, causing undesired temperature increase. The button can be solid copper, or copper plated. Solid copper is preferred. This button design needs to achieve performance requirements that are not typical for most standard BPM buttons.