4 - PPQ _PAST_PERFORMANCE_QUESTIONNAIRE FA486125R0003.pdf

PDF 192 KB Posted

Attached to
SABER IDIQ
Solicitation number
FA486125R0003
Issued by

About this file

This document is a Past Performance Questionnaire (PPQ) for a Simplified Acquisition of Base Engineer Requirements (SABER) Indefinite Delivery/Indefinite Quantity (IDIQ) contract solicitation (FA4861125R0003) supporting Nellis AFB, Creech AFB, and Nevada Test and Training Range. The PPQ is designed to evaluate a contractor's previous performance by having a prior contracting officer complete a detailed assessment across three key performance areas: quality, schedule, and management.

The evaluation uses a five-tier rating scale ranging from Exceptional (EX) to Unsatisfactory (UNS), with specific criteria for each rating. The questionnaire requires the evaluating contracting officer to rate the contractor's performance in managing quality control programs, adhering to construction standards, meeting contract timelines and milestones, and demonstrating effective project management and coordination. Submission of this form is mandatory when Contractor Performance Assessment Reporting System (CPARS) records are not available, and it serves as a critical component of the source selection process for the SABER IDIQ contract.

View the file

Other files

File Type Posted
Solicitation Amendment FA486125R00030017 SF 30.pdf PDF
Solicitation Amendment - FA486125R00030017.pdf PDF
Solicitation Amendment - FA486125R00030013.pdf PDF
Attach 79 RFI Log SABER Seed 29 Jan 2026_.xlsx XLSX spreadsheet
Solicitation Amendment FA486125R00030011 SF 30 .pdf PDF
2 - Price Schedule _13 Jan 2026.xlsx XLSX spreadsheet
3 - Self Scoring Matrix 7_Jan 26.xlsx XLSX spreadsheet
44 -Statement of Objectives (SOO) for RKMF 240010 20 Nov 25.pdf PDF
Solicitation Amendment - FA486125R00030009.pdf PDF
Solicitation Amendment FA486125R00030009_SF 30.pdf PDF
Solicitation Amendment FA486125R00030006 SF 30.pdf PDF
(Attachment 57) SABER Seed SOO Honor Guard Building 10250 Attachment 3 - As-Builts 65 LOCATION and GRADING.pdf PDF
(Attachment 58) SABER Seed SOO Honor Guard Building 10250 Attachment 5 - Attachment 5 AFGIMS Utilities Snapshot.pdf PDF
(Attachment 60) SABER Seed SOO Honor Guard Building 10250 Attachment 7 - Sewer Line with Measurements and Pictures.pdf PDF
(Attachment 68) SABER Seed SOO Honor Guard Building 10250 Attachment 15 - B10250 room numbers.pdf PDF
(Attachment 70) SABER Seed SOO Honor Guard Building 10250 Attachment 17 - Double Check Valve Assembly.pdf PDF
(Attachment 56) SABER Seed SOO Honor Guard Building 10250 Attachment 2- HAZMAT Results 10250 Restrooms part 2.pdf PDF
Solicitation Amendment - FA486125R00030005.pdf PDF
Solicitation Amendment FA486125R00030004 SF 30.pdf PDF
Solicitation Amendment FA486125R00030003 SF 30 .pdf PDF
Attachment 53 Gordian SABER Technical Specifications.pdf PDF
Solicitation Amendment FA486125R00030002 SF 30.pdf PDF
Atch 41 NV20250038 19Sep25 Bldg Clark.pdf PDF
Atch 43 NV20250001 1Aug25 NTTR.pdf PDF
Solicitation Amendment - FA486125R00030001.pdf PDF
Atch 42 NV20250058 19Sep25 Hwy Clark.pdf PDF
Atch 50_RFI Log_General Solicitation.xlsx XLSX spreadsheet
Atch 51_RFI Log_ SABER Seed.xlsx XLSX spreadsheet
Solicitation - FA486125R0003.pdf PDF
8_Nellis-Creech Lighting Req 2019-01-22.pdf PDF
12 - Env Permit-ATP Guidance 2023.pdf PDF
15 - Hazardous Material Management Guidance Document 2023-06-03.pdf PDF
18 - Nellis Supplement to DAFI 31-218 Motor Vehicle Traffic Supervision - 23 Mar 2023.pdf PDF
23_Power Trench Sand and Backfill Requirements - Apr 2013.pdf PDF
27 - NTTR Visit Request - 27 Jan 2023.pdf PDF
28 - Nuclear Gauge Form 1.xlsx XLSX spreadsheet
29 - Nuclear Gauge Form 2.docx DOCX document
30 - AF Form 103 Base Civil Engineering Work Clearance Request - 01 Aug 1994.pdf PDF
39 - Form SS-PER-007-003 Internal Combustion Engine Worksheet.pdf PDF
42 - General Decision Number NV20240001 Bldg NTTR.pdf PDF
47 - Example SABER Design Intent Drawing Set Level 2_20 Nov.pdf PDF
52 - 99 SFS - Mass Pass Request Template.xlsx XLSX spreadsheet
6 - Nellis-Creech Comm Req NC 2710 - Jun 2023.pdf PDF
14_ACC Sole Source EMCS Letter.pdf PDF
21_US3.PJ Single and Three Phase Primary Junctions - Aug 2016.pdf PDF
22_RUS Bulletin 1728F-806 UG Main VEA Standard - 18 October 2018.pdf PDF
25 - UH1.2 - Grounding Assembly for Pad-mounted Transformers and Enclosures 2 Rods - Aug 2016.pdf PDF
34 - Schedule of Values Template.xlsx XLSX spreadsheet
43 - General Decision Number_NV20250024 Heavy Clark County.pdf PDF
50_RFI Log_General Solicitation and Non-SABER Seed Related Questions.xlsx XLSX spreadsheet
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 4- PAST PERFORMANCE

QUESTIONNAIRE FA486125R0003

FOR OFFICIAL USE ONLY

SOURCE SELECTION INFORMATION – SEE FAR 3.104

NELLIS FA4861125R0003 SABER

PAST PERFORMANCE QUESTIONNAIRE (PPQ)

The contractor, which is named below, requires this PPQ to be completed for a proposal for a

Solicitation. This solicitation is in support of Nellis AFB, Creech AFB and Nevada Test and Training

Range. The solicitation in question is FA4861125R0003 for a Simplified Acquisition of Base Engineer

Requirements (SABER) IDIQ.

Submission of this form is mandatory for the evaluation of Contractor past performance if CPARS are not available. No other form of past performance evaluation will be considered for evaluation.

A primary consideration in our selection process is the contractor’s history of performance of similar efforts. Please make every effort to be thorough in your answers/comments. Return the completed questionnaire to the referenced contractor:_________________ at_____________________________.

Please refer any questions to: Corrine Lemon at (702-652-6196) or (corrine.lemon@us.af.mil)

A. GENERAL INFORMATION OF CONTRACTOR (completed by Offeror)

Contractor Name:_______________________________________________________________

CAGE:_______________________ UEI:____________________________________________

Telephone Number:_______________ Point of Contact:_________________________________

B. RESPONDENT INFORMATION (completed by evaluating Contracting Officer)

Name:_______________________________________________________________________

Title:________________________________________________________________________

Organization:__________________________________________________________________

Address:_____________________________________________________________________

Telephone_______________________________ Email:_______________________________

C. CONTRACT INFORMATION

Contract Number:______________________________________________________________

Title: ______________________________________________________________________

Was this contract an Air Force SABER?___________________________________________

Was this contract a MACC or Design Build Contract?________________________________

Period of Performance:____________________ Dollar Amount of Contract:_______________

Description___________________________________________________________________

D. PERFORMANCE INFORMATION:

For the section below, please indicate your satisfaction with the contractor’s performance by highlighting in the appropriate block code using the scale provided to the right of each question. This scale is defined as follows:

CODE PERFORMANCE RATING

EX EXCEPTIONAL - Performance meets contractual requirements and exceeds many to the benefit of the customer. The contractual performance of the element or sub-element being evaluated was accomplished with few minor problems for which corrective actions taken by the Contractor were highly effective.

VG VERY GOOD - Performance meets contractual requirements and exceeds some to the customer’s benefit. The contractual performance of the element or sub-element being evaluated was accomplished with some minor problems for which corrective actions taken by the Contractor were effective.

SAT SATISFACTORY - Performance meets contractual requirements. The contractual performance of the element or sub-element contains some minor problems for which corrective actions taken by the Contractor appear, or were, satisfactory.

M MARGINAL - Performance does not meet some contractual requirements. The contractual performance of the element or sub-element being evaluated reflects a serious problem for which the Contractor has not yet identified corrective actions. The Contractor's proposed actions appear only marginally effective or were not fully implemented.

UNS UNSATISFACTORY - Performance does not meet most contractual requirements, and recovery is not likely in a timely manner. The contractual performance of the element or sub-element contains a serious problem(s) for which the Contractor's corrective actions appear or were ineffective.

Please use the above ratings to describe the contractor’s performance in the following areas:

1. Quality

Assess the contractor’s performance in terms of quality. Consider how effectively they managed their quality control program and upheld construction standards. This includes their consistency in performing accessory testing, executing the three-phase inspection process, and maintaining thorough Contractor Quality Control (CQC) documentation.

EX VG SAT M UNS

3. Management

Assess the integration and coordination of all activities needed to execute the contract/order, specifically the timeliness, completeness and quality of problem identification, corrective action plans, proposal submittals, the contractor’s history of reasonable and cooperative behavior (to include timely identification of issues in controversy), customer satisfaction, timely award and management of subcontracts.

I certify that I am a Contracting Officer or contract professional responsible for the subject contractor evaluation. All information provided is true and valid to the best of my knowledge.

Evaluator’s Signature Date

2. Schedule

Assess the timeliness of the contractor against the completion of the contract, task orders, milestones, delivery schedules, and administrative requirements (e.g., efforts that contribute to or affect the schedule variance). This rating of the contractor’s adherence to the required delivery schedule should include the contractor’s efforts during the evaluation period that contribute to or affect the schedule variance. Also, consider the significance of scheduled events and assess the effectiveness of contractor corrective actions.

File details come from the government source that posted it. Updated .