This solicitation package describes a federal construction contract opportunity for the Department of Veterans Affairs. The project consists of constructing a new clean core surgery suite space and renovating existing areas at the Providence VA Medical Center in Rhode Island. The work includes building an elevated second floor addition measuring approximately 3,900 gross square feet and renovating 2,900 gross square feet of existing first floor space. The solicitation will be a request for proposal evaluated using lowest price technically acceptable procedures. The NAICS code is 236220 and the size standard is $39.5 million. The solicitation period of performance is approximately 490 calendar days from notice to proceed with a magnitude of construction between $5 million to $10 million. The solicitation will be set aside as a total SDVOSB and issue on or around October 16, 2019. All questions must be submitted in writing by the specified date.
36E77619R0097 Attachment 4 - Fire Protection Plans.pdf
View the file
Other files for this federal contract opportunity
Show all 44
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEMI-RECESSED SPRINKLER
SPRINKLER RISER
SPRINKLER PIPE, SIZE (INCHES) AND LENGTH (FEET-INCHES) AS INDICATED
FLOOR CONTROL VALVE ASSEMBLY
HYDRAULIC CALCULATION TAG
FIRE SPRINKLER LEGEND
FCVA
A
EXISTING PENDANT SPRINKLER
INSPECTOR'S TEST CONNECTION
ITC
GENERAL NOTES:
1. PROVIDE A WET PIPE FIRE PROTECTION SYSTEM THROUGHOUT INTERIOR PROJECT
WORK AREAS AND A DRY PIPE FIRE PROTECTION SYSTEM UNDER THE FLOOR
OVERHANG IN ACCORDANCE WITH VA FIRE PROTECTION DESIGN MANUAL (7TH
EDITION) AND NFPA 13 (2015 EDITION).
2. THESE DRAWINGS ILLUSTRATE THE CONFIGURATION OF MAJOR SYSTEM
COMPONENTS. THEY ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO
SHOW EXACT LOCATIONS. PIPE LENGTHS AND ELEVATIONS INDICATED ON THE
DRAWINGS (IF SHOWN) ARE APPROXIMATE. COORDINATE FINAL INSTALLATION WITH
ACTUAL FIELD CONDITIONS AND OTHER CONSTRUCTION TRADES. THE CONTRACTOR
SHALL DESIGN AND INSTALL THE SPRINKLER SYSTEM TO PROVIDE COMPLETE
PROTECTION THROUGHOUT THE PROJECT WORK AREAS IN ACCORDANCE WITH NFPA
13.
3. PROVIDE SHOP DRAWINGS WITH FINAL SPRINKLER SYSTEM LAYOUT, PIPE SIZING,
SPRINKLER HYDRAULIC CALCULATIONS, AND COORDINATION WITH ALL OTHER
TRADES.
4. PROVIDE QUICK RESPONSE SPRINKLERS IN ALL AREAS UNLESS OTHERWISE
NOTED. PENDANT SPRINKLERS SHALL BE INSTALLED IN FINISHED CEILING AREAS.
5. PROVIDE CUTTING AND PATCHING OF WALLS AND CEILING NECESSARY TO
PERFORM INSTALLATION OF FIRE SPRINKLER SYSTEM.
6. PROVIDE SLEEVES AND UL LISTED FIRESTOP ASSEMBLIES AT ALL PIPE
PENETRATIONS TO MAINTAIN FIRE-RESISTANCE RATINGS AS INDICATED ON LIFE
SAFETY PLANS. UL CLASSIFICAITONS AND MATERIAL PRODUCT DATA SHEET FOR ALL
FIRESTOP SYSTEMS SHALL BE SUBMITTED AND APPROVED BEFORE ANY
FIRESTOPPING SYSTEMS ARE INSTALLED.
7. THE DESIGN OF THE SPRINKLER SYSTEM IS BASED ON THE HYDRAULIC METHOD
DESCRIBED IN NFPA 13 USING THE AREA/DENSITY/HOSE REQUIREMENTS:
A. LIGHT HAZARD OCCUPANCIES: 0.10 GPM/SQFT FOR THE HYDRAULICALLY MOST
REMOTE 1,500 SQFT WITH 100 GPM HOSE ALLOWANCE INCLUDES: PATIENT CARE,
TREATMENT, OFFICE, AND CUSTOMARY ACCESS AREAS.
B. ORDINARY HAZARD GROUP 1 OCCUPANCIES: 0.15 GPM/SQFT FOR THE
HYDRAULICALLY MOST REMOTE 1,500 SQFT (OR ENTIRE AREA IF LESS THAN 1,500
SQFT) WITH 250 GPM HOSE ALLOWANCE INCLUDES: MECHANICAL EQUIPMENT
ROOMS, TRANSFORMER ROOMS, ELECTRICAL SWITCHGEAR ROOMS, AND
ELECTRIC CLOSETS.
C. ORDINARY HAZARD GROUP 2 OCCUPANCIES: 0.20 GPM/SQFT FOR THE
HYDRAULICALLY MOST REMOTE 1,500 SQFT (OR ENTIRE AREA IF LESS THAN 1,500
SQFT) WITH 250 GPM HOSE ALLOWANCE INCLUDES: STORAGE ROOMS, TRASH
ROOMS, CLEAN AND SOILED LINEN ROOMS, AND OTHER STORAGE AREAS.
SPRINKLER HAZARD CLASSIFICATION SCHEDULE:
LH = LIGHT HAZARD
OH1 = ORDINARY HAZARD GROUP 1
OH 2 = ORDINARY HAZARD GROUP 2
ETR = EXISTING TO REMAIN
WATER SUPPLY INFORMATION:
REFER TO THE WATER SUPPLY REPORT CONTAINED IN THE SPECIFICATIONS FOR
MORE DETAILED INFORMATION.
CODE RED CONSULTANTS, LLC
154 TURNPIKE ROAD, SUITE 200
SOUTHBOROUGH, MA 01772
FIRE PROTECTION ENGINEERING
EXISTING SPRINKLER PIPING
SPRINKLER PIPING TO BE DEMOLISHED
NEW SPRINKLER PIPING
EXISTING CONCEALED SPRINKLER
PENDANT SPRINKLER
CONCEALED SPRINKLER
EXISTING SEMI-RECESSED SPRINKLER
CAP OR END OF PIPING
PIPING INTERRUPTED OR TO BE CONTINUED
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
FINAL CONSTRUCTION
DOCUMENTS
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Auburn, ME 207.784.5100
Boston, MA 617.426.5050
Portland, ME 207.775.0053
Portsmouth, NH 603.626.1242 c HA PROJECT NUMBER: 13586
CONSTRUCT CLEAN CORE ADDITION TO
SURGICAL SUITE
PROVIDENCE, RHODE ISLAND
650-337
FIRE PROTECTION LEGEND AND
GENERAL NOTES
2-22-19
CN
CL
FP0.0
Revisions: Date:
EXISTING TO REMAIN
ETR
DRY SPRINKLER VALVE
DRY PIPE
DRY
| 10_FP0-0 |
| 10_FP10-1 |
| 10_FP10-2 |
| 10_FP10-3 |
| FP00.0 |
| Layout1 |
| FP10.1 |
| FP10.2 |
| FP10.3 |
| LS10.2 |
11_LS10-2