This document provides details for a federal contract solicitation to construct a clean core addition to a surgical suite at a Department of Veterans Affairs medical center. The solicitation will be a Request for Proposal conducted in accordance with FAR Parts 15, 19, and 36 and evaluated using Lowest Price Technically Acceptable procedures. The work includes constructing approximately 2,900 square feet of renovated existing space and 3,900 square feet of new space, with a 490 calendar day period of performance. The solicitation will be advertised as a total Service-Disabled Veteran-Owned Small Business set-aside with a NAICS code of 236220 and size standard of $39.5 million. All questions must be submitted in writing by the specified date, with the magnitude of construction estimated between $5 million to $10 million.
36E77619R0097 0004 P01 - SKA02 - REVISED DOOR SCHEDULE.pdf
View the file
Other files for this federal contract opportunity
Show all 44
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Graphic Scale
HA Project No.
Scale
Date
Harriman Associatesc
Auburn
Boston
Portland
Portsmouth
SKA02
REVISED DOOR
SCHEDULE
PROVIDENCE, RHODE ISLAND
650-337
12-03-19
CONSTRUCT CLEAN
CORE
ADDITION TO SURGICAL
SUITE
DOOR AND FRAME SCHEDULE
DOOR
MARK
DOOR PANELS FRAME
FIRE
RATING
HDW
SET REMARKSPANEL SIZE
MAT TYPE LEAF 2
TYPE
MAT /
FIN TYPE
DETAILS
No. W LEAF 2
W H T HEAD JAMB SILL
LEVEL 02
201.2 (1) 3' - 0" 7' - 0" 1 3/4" WD F HM 1 F3 F4 - HW-1A
202.1 (1) 3' - 0" 7' - 0" 1 3/4" WD F HM 1 F3 F4 - HW-1A
202A (1) 3' - 0" 7' - 0" 1 3/4" WD F HM 1 F3 F4 - HW-2
203 (2) 3' - 0" 3' - 0" 7' - 0" 1 3/4" WD N HM F2 F4 - 90 MIN HW-10A
206.2 (1) 4' - 0" 7' - 0" 1 3/4" WD F HM 1 F3 F4 - HW-1N REFER TO F1/A60.1 FOR JAMB
FRAMING REVISION
207.2 (1) 4' - 0" 7' - 0" 1 3/4" WD F HM 1 F3 F4 - HW-1N REFER TO F1/A60.1 FOR JAMB
FRAMING REVISION
208.2 (1) 4' - 0" 7' - 0" 1 3/4" WD F HM 1 F3 F4 - HW-1N REFER TO F1/A60.1 FOR JAMB
FRAMING REVISION
208.3 (2) 3' - 0" 3' - 0" 7' - 0" 1 3/4" WD N HM 1 F3 F4 - HW-8B
209.2 (1) 4' - 0" 7' - 0" 1 3/4" WD F HM 1 F3 F4 - HW-1N REFER TO F1/A60.1 FOR JAMB
FRAMING REVISION
210 (2) 3' - 6" 3' - 6" 7' - 0" 1 3/4" WD F HM 1 F2 F4 - HW-8B .
211 (1) 3' - 0" 7' - 0" 1 3/4" WD F HM 2 F3 F4 HW-1A
221 (1) 3' - 0" 7' - 0" 1 3/4" WD F HM 1 F2 F4 - HW3G
222.2 (2) 3' - 0" 3' - 0" 7' - 0" 1 3/4" WD N HM 1 F2 F4 - 90 MIN HW-10A
250 (1) 4' - 0" 7' - 0" 1 3/4" WD N HM 1 F2 F4 - HW-4P
251 (1) 3' - 0" 7' - 0" 1 3/4" WD F HM 1 F2 F4 - 45 MIN HW-5B
252 (2) 3' - 0" 3' - 0" 7' - 0" 1 3/4" WD N HM F2 F4 - 45 MIN HW-10A2
253 (1) 3' - 0" 7' - 0" 1 3/4" WD HG HM 1 F2 F4 - HW-3E
254 (1) 3' - 8" 7' - 0" 1 3/4" WD F HM 1 F2 F4 - 45 MIN HW-4K
255 (1) 3' - 8" 7' - 0" 1 3/4" WD HG HM 1 F2 F4 - 45 MIN HW-1K
256.1 (1) 3' - 0" 7' - 0" 1 3/4" WD HG HM 1 F2 F4 - 45 MIN HW-4C
256.2 (1) 3' - 8" 7' - 0" 1 3/4" WD HG HM 1 F2 F4 - HW-4C
257 (1) 3' - 6" 7' - 0" 1 3/4" HM F HM 2 F2 F4 - HW-5G
260 (1) 4' - 0" 7' - 0" 1 3/4" WD HG HM 1 F2 F4 - 45 MIN HW-1N
261 (1) 4' - 0" 7' - 0" 1 3/4" WD F HM 1 F2 F4 - 45 MIN HW-1N
263.1 (2) 3' - 0" 3' - 0" 7' - 0" 1 3/4" WD N HM 1 F2 F4 - HW-8B
263.2 (1) 4' - 0" 7' - 0" 1 3/4" WD N HM 1 F2 F4 - 45 MIN HW-1N
264 (2) 3' - 0" 3' - 0" 7' - 0" 1 3/4" WD F HM 1 F2 F4 - HW-11
265.1 (2
UNEQUAL) 4' - 0" 2' - 0" 7' - 0" 1 3/4" WD N N HM F2 F4 - 45 MIN HW-8B
N
F
N
N
F
N
N 2