0004 - 596-22-700 Drawings 01_Environmental Revisions.pdf
PDF 2 MB Posted
- Solicitation number
- 36C77625B0040
About this file
These are Bid Documents for the Veterans Health Administration's Environmental Hazards Infrastructure Upgrades project at the Lexington VA Health Care facility in Lexington, Kentucky. The documents detail environmental remediation work across multiple floors of Buildings 1 and 25, specifically focusing on asbestos and lead-based material abatement. Key scope elements include removing asbestos-containing materials such as pipe insulation, floor tiles, ceiling tiles, and mastic, as well as performing lead-based paint spot removal, all within carefully controlled negative pressure enclosures. The project involves manual removal methods, disposal of hazardous materials, and coordinating work to minimize disruption to VA healthcare operations. The bid documents are dated 03/15/2024, prepared by SPUR Design, LLC, and are fully sprinklered construction documents intended for bidding purposes.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
FULLY SPRINKLERED
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
/2
2/
:2 3:
A
M
BUILDING 1 - GROUND FLOOR -
ENVIRONMENTAL HAZARDS
CD 06 258JR
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511 HA010
SPUR #: 2207.00
No. REVISION DESCRIPTION DATE
NOT TO SCALE
BUILDING 1 - GROUND FLOOR
HAZARDOUS MATERIALS KEYNOTES
AN ASBESTOS-CONTAINING GRAY MASTIC EXISTS ON FIBERGLASS LINES AND FITTINGS THROUGHOUT BUILDING. UNLESS OTHERWISE SPECIFIED AVOID DISTURBANCE. ANY WORK IMPACTING THIS MATERIAL MUST BE PERFORMED BY LICENSED ASBESTOS ABATEMENT CONTRACTORS.
AN ASBESTOS-CONTAINING WHITE SINK SOUNDPROOFING MATERIAL IS KNOWN TO EXIST WITHIN BUILDING 1. AVOID ANY WORK LIKELY TO IMPACT SINKS COVERED IN THIS
WHITE SINK SOUNDPROOFING MATERIAL. SINKS LOCATED THROUGHOUT
AREA OF KNOWN AND/OR PRESUMED ASBESTOS CONTAINING BLACK COATING ON INSIDE OF EXTERIOR WALL, AND WATERPROOFING BELOW GRADE. WITHIN A NPE (NEGATIVE PRESSURE ENCLOSURE) , USING MANUAL MEANS, PROVIDE WALL PENETRATION(S). REFERENCE MECHANICAL, ELECTRICAL, AND TELECOMMUNICATION DRAWING SETS FOR DETAILS. NOTE - TELECOMMUNICATION PATHWAYS TO BE LOCATED WITHIN NEW DUCT BANKS HAVE A SLIGHTLY DIFFERENT ENTRY/EXIT POINT THAN THOSE INDICATED WITHIN THE CIVIL DRAWING SET. COORDINATE EXACT LOCATIONS AND QUANTITIES WITH COR, GC (GENERAL CONTRACTOR), AND OTHER IMPACTED PROFESSIONS AND
TRADES. ESTIMATED 3 SF EACH AT 3 LOCATIONS
WITHIN AN NPE, USING MANUAL MEANS, REMOVE, TO THE EXTENTS INDICATED BY ARCH (ARCHITECTURAL DRAWING SET), ACM (ASBESTOS-CONTAINING MATERIAL) 12" TAN W/ WHITE/GRAY/BROWN FLECK AND UNDERLYING ACM FLOOR TILE AND ACM BLACK MASTIC, 120 SF
WITHIN AN NPE, USING MANUAL AND GLOVEBAG METHODS, REMOVE, TO THE EXTENTS INDICATED BY ARCH. NON-ACM, LEAD BASED PAINTED PLASTER CEILING AND DAMAGED ACM PIPE/FITTING INSULATION ABOVE. REMOVE PIPE/FITTING INSULATION AT LEAST 3 LF INTO SPACE OVER REMAINING PLASTER TO ALLOW FOR BUFFER ZONE FOR NEW WALL CONSTRUCTION. HEPA VACUUM REMAINING ACM CONTAMINATED PLASTER CEILING AND ENCAPSULATE. .COORDINATE DATA AND UTILITY SHUTDOWN WITH COR, GC, AND OTHER IMPACTED PROFESSIONS AND TRADES, 120 SF OF PLASTER AND ESTIMATED 25 LF OF PIPE/FITTING INSULATION
LBP (LEAD-BASED PAINT) ON PLASTER CEILINGS. DO NOT DISTURB. ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT
CONTRACTOR. THROUGHOUT
LBP ON METAL STEAM LINES. DO NOT DISTURB. ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT CONTRACTOR.
THROUGHOUT
HAZARDOUS MATERIALS ALONG LIKELY ROUTING PATHWAYS ABOVE CEILING TILE. LEAD BASED PAINT ON CONCRETE &/OR PLASTER CEILING. WITHIN A NEGATIVE PRESSURE ENCLOSURE, USING CHEMICAL AND MANUAL METHODS, PERFORM SPOT REMOVAL OF LEAD BASED PAINT AT ANCHOR POINTS. 1 SF EACH LOCATION AT APPROXIMATELY 50 LOCATIONS. COORDINATE EXACT LOCATIONS AND QUANTITIES WITH GC AND OTHER AFFECTED TRADES.
USING GLOVEBAG METHODS WITHIN A NEGATIVE PRESSURE ENCLOSURE, REMOVE OUT OF CHASE FIBERGLASS PIPE INSULATION AND RELATED FITTINGS. PIPE INSUALTION SYSTEMS HAVE INTERMITTENT APPLIED ASBESTOS GRAY MASTIC IN THE APPROXIMATE FOLLOWING QUANTITIES; 25 LF OF PIPE INSULATION AND FITTINGS IN ROOM.
REFERENCE DRAWING M-401 FOR LOCATIONS OF PIPE TO BE REMOVED
A1
A2
A3
A4
A5
L1
L2
L3
3131A
A3
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
N
BID DOCUMENTS
1 ADDENDUM 1 7/29/2025
A6
A2 L2L1 L3A1
A4 A5
A3 A6
VISUAL KEY
LIMITS OF NEGATIVE PRESSURE ENCLOSURE(S) WITH APPROPRIATE
THREE STAGE DECON, TWO STAGE LOADOUT, AND NEGATIVE AIR
MACHINES WITH THREE STAGE HEPA FILTRATION ALL IN ACCORDANCE
WITH SPECIFICATIONS. TUBING SHALL BE VENTED TO THE BUILDING
EXTERIOR. EXHAUST TUBING AND OUTFLOW SHALL BE LOCATED SO AS
TO AVOID DISRUPTION TO VA OPERATIONS. COORDINATE EXHAUST
LOCATIONS WITH COR. REFER TO PHASING SHEETS FOR SPECIFIC
PROJECT-WIDE PHASING.
MAINTAIN A MINIMUM OF ½ THE WIDTH OF THE HALLWAYS FOR FREE
ACCESS TO MOVE PATIENTS. COORDINATE WITH THE VA-COR TO ALLOW
FOR ADEQUATE PASSAGE OF PATIENTS WHERE ASPECTS OF THE NPE
MAY RESTRICT PATIENT MOVEMENTS ON ROLLING TRANSPORTS.
e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
FULLY SPRINKLERED
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
/2
2/
:2 3:
A
M
BUILDING 1 - FIRST FLOOR -
ENVIRONMENTAL HAZARDS
CD 07 258JR
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511 HA011
SPUR #: 2207.00
No. REVISION DESCRIPTION DATE
NOT TO SCALE
BUILDING 1 - FIRST FLOOR
HAZARDOUS MATERIALS KEYNOTES
AN ASBESTOS-CONTAINING GRAY MASTIC EXISTS ON FIBERGLASS LINES AND FITTINGS THROUGHOUT BUILDING. UNLESS OTHERWISE SPECIFIED AVOID DISTURBANCE. ANY WORK IMPACTING THIS MATERIAL MUST BE PERFORMED BY LICENSED ASBESTOS ABATEMENT CONTRACTORS.
AN ASBESTOS-CONTAINING WHITE SINK SOUNDPROOFING MATERIAL IS KNOWN TO EXIST WITHIN BUILDING 1. AVOID ANY WORK LIKELY TO IMPACT SINKS COVERED IN THIS
WHITE SINK SOUNDPROOFING MATERIAL.
LBP ON PLASTER CEILINGS. DO NOT DISTURB. ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT CONTRACTOR.
LBP ON METAL STEAM LINES. DO NOT DISTURB. ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT CONTRACTOR.
HAZARDOUS MATERIALS ALONG LIKELY ROUTING PATHWAYS ABOVE CEILING TILE. LEAD BASED PAINT ON CONCRETE &/OR PLASTER CEILING. WITHIN A NEGATIVE PRESSURE ENCLOSURE, USING CHEMICAL AND MANUAL METHODS, PERFORM SPOT REMOVAL OF LEAD BASED PAINT AT ANCHOR POINTS. 1 SF EACH LOCATION AT APPROXIMATELY 50 LOCATIONS. COORDINATE EXACT LOCATIONS AND QUANTITIES WITH GC AND OTHER AFFECTED TRADES.
USING GLOVEBAG METHODS WITHIN A NEGATIVE PRESSURE ENCLOSURE, REMOVE OUT OF CHASE FIBERGLASS PIPE INSULATION AND RELATED FITTINGS. PIPE INSUALTION SYSTEMS HAVE INTERMITTENT APPLIED ASBESTOS GRAY MASTIC IN THE APPROXIMATE FOLLOWING QUANTITIES; 55 LF OF PIPE INSULATION AND FITTINGS IN ROOM AND 12 LF OF PIPE INSULATION RELATED TO DEMOLITION OF CFU. REFERENCE DRAWING M-401 FOR LOCATIONS OF PIPE TO BE REMOVED
A1
A2
L1
L2
L3
147A-1
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
A2 L2L1 L3A1
BID DOCUMENTS
1 ADDENDUM 1 7/29/2025
A3
A3
VISUAL KEY
LIMITS OF NEGATIVE PRESSURE ENCLOSURE(S) WITH APPROPRIATE
THREE STAGE DECON, TWO STAGE LOADOUT, AND NEGATIVE AIR
MACHINES WITH THREE STAGE HEPA FILTRATION ALL IN ACCORDANCE
WITH SPECIFICATIONS. TUBING SHALL BE VENTED TO THE BUILDING
EXTERIOR. EXHAUST TUBING AND OUTFLOW SHALL BE LOCATED SO AS
TO AVOID DISRUPTION TO VA OPERATIONS. COORDINATE EXHAUST
LOCATIONS WITH COR. REFER TO PHASING SHEETS FOR SPECIFIC
PROJECT-WIDE PHASING.
MAINTAIN A MINIMUM OF ½ THE WIDTH OF THE HALLWAYS FOR FREE
ACCESS TO MOVE PATIENTS. COORDINATE WITH THE VA-COR TO ALLOW
FOR ADEQUATE PASSAGE OF PATIENTS WHERE ASPECTS OF THE NPE
e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
FULLY SPRINKLERED
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
/2
2/
:2 3:
A
M
BUILDING 1 - SECOND FLOOR -
ENVIRONMENTAL HAZARDS
CD 08 258JR
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511 HA012
SPUR #: 2207.00
No. REVISION DESCRIPTION DATE
NOT TO SCALE
BUILDING 1 - SECOND FLOOR
HAZARDOUS MATERIALS KEYNOTES
AN ASBESTOS-CONTAINING GRAY MASTIC EXISTS ON FIBERGLASS LINES AND FITTINGS THROUGHOUT BUILDING. UNLESS OTHERWISE SPECIFIED AVOID DISTURBANCE. ANY WORK IMPACTING THIS MATERIAL MUST BE PERFORMED BY LICENSED ASBESTOS ABATEMENT CONTRACTORS.
AN ASBESTOS-CONTAINING WHITE SINK SOUNDPROOFING MATERIAL IS KNOWN TO EXIST WITHIN BUILDING 1. AVOID ANY WORK LIKELY TO IMPACT SINKS COVERED IN THIS
WHITE SINK SOUNDPROOFING MATERIAL.
WITHIN A NPE, USING MANUAL MEANS, REMOVE NON-ACM 12" CREAM W/ TAN FLECK AND UNDERLYING ACM BLACK MASTIC, 94 SF
LBP ON PLASTER CEILINGS. DO NOT DISTURB.ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT CONTRACTOR.
LBP ON METAL STEAM LINES. DO NOT DISTURB.ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT CONTRACTOR.
HAZARDOUS MATERIALS ALONG LIKELY ROUTING PATHWAYS ABOVE CEILING TILE. LEAD BASED PAINT ON CONCRETE &/OR PLASTER CEILING. WITHIN A NEGATIVE PRESSURE ENCLOSURE, USING CHEMICAL AND MANUAL METHODS, PERFORM SPOT REMOVAL OF LEAD BASED PAINT AT ANCHOR POINTS. 1 SF EACH LOCATION AT APPROXIMATELY 50 LOCATIONS. COORDINATE EXACT LOCATIONS AND QUANTITIES WITH GC AND OTHER AFFECTED TRADES.
USING GLOVEBAG METHODS WITHIN A NEGATIVE PRESSURE ENCLOSURE, REMOVE OUT OF CHASE FIBERGLASS PIPE INSULATION AND RELATED FITTINGS. PIPE INSUALTION SYSTEMS HAVE INTERMITTENT APPLIED ASBESTOS GRAY MASTIC IN THE APPROXIMATE FOLLOWING QUANTITIES; 46 LF OF PIPE INSULATION AND FITTINGS IN ROOM AND 12 LF OF PIPE INSULATION RELATED TO DEMOLITION OF CFU. REFERENCE DRAWING M-401 FOR LOCATIONS OF PIPE TO BE REMOVED
A1
A2
A3
L1
L2
L3
229-1
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
A2 L2L1 L3A1
BID DOCUMENTS
A3
1 ADDENDUM 1 7/29/2025
A4
A4
VISUAL KEY
LIMITS OF NEGATIVE PRESSURE ENCLOSURE(S) WITH APPROPRIATE
THREE STAGE DECON, TWO STAGE LOADOUT, AND NEGATIVE AIR
MACHINES WITH THREE STAGE HEPA FILTRATION ALL IN ACCORDANCE
WITH SPECIFICATIONS. TUBING SHALL BE VENTED TO THE BUILDING
EXTERIOR. EXHAUST TUBING AND OUTFLOW SHALL BE LOCATED SO AS
TO AVOID DISRUPTION TO VA OPERATIONS. COORDINATE EXHAUST
LOCATIONS WITH COR. REFER TO PHASING SHEETS FOR SPECIFIC
PROJECT-WIDE PHASING.
MAINTAIN A MINIMUM OF ½ THE WIDTH OF THE HALLWAYS FOR FREE
ACCESS TO MOVE PATIENTS. COORDINATE WITH THE VA-COR TO ALLOW
FOR ADEQUATE PASSAGE OF PATIENTS WHERE ASPECTS OF THE NPE
e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
FULLY SPRINKLERED
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
/2
2/
:2 3:
A
M
BUILDING 1 - THIRD FLOOR -
ENVIRONMENTAL HAZARDS
CD 09 258JR
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511 HA013
SPUR #: 2207.00
No. REVISION DESCRIPTION DATE
NOT TO SCALE
BUILDING 1 - THIRD FLOOR
HAZARDOUS MATERIALS KEYNOTES
AN ASBESTOS-CONTAINING GRAY MASTIC EXISTS ON FIBERGLASS LINES AND FITTINGS THROUGHOUT BUILDING. UNLESS OTHERWISE SPECIFIED AVOID DISTURBANCE. ANY WORK IMPACTING THIS MATERIAL MUST BE PERFORMED BY LICENSED ASBESTOS ABATEMENT CONTRACTORS.
AN ASBESTOS-CONTAINING WHITE SINK SOUNDPROOFING MATERIAL IS KNOWN TO EXIST WITHIN BUILDING 1. AVOID ANY WORK LIKELY TO IMPACT SINKS COVERED IN THIS WHITE SINK
SOUNDPROOFING MATERIAL.
WITHIN A NPE, USING MM's, REMOVE NON-ACM 12" BEIGE WITH LONG BROWN STREAK, NON-ACM MASTIC, LEVELING COMPOUND, AND UNDERLYING RESIDUAL ACM BLACK MASTIC. ~87 SF
LBP ON PLASTER CEILINGS. DO NOT DISTURB.ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT CONTRACTOR.
LBP ON METAL STEAM LINES. DO NOT DISTURB.ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT CONTRACTOR.
HAZARDOUS MATERIALS ALONG LIKELY ROUTING PATHWAYS ABOVE CEILING TILE. LEAD BASED PAINT ON CONCRETE &/OR PLASTER CEILING. WITHIN A NEGATIVE PRESSURE ENCLOSURE, USING CHEMICAL AND MANUAL METHODS, PERFORM SPOT REMOVAL OF LEAD BASED PAINT AT ANCHOR POINTS. 1 SF EACH LOCATION AT APPROXIMATELY 50 LOCATIONS.
COORDINATE EXACT LOCATIONS AND QUANTITIES WITH GC AND OTHER AFFECTED TRADES.
USING GLOVEBAG METHODS WITHIN A NEGATIVE PRESSURE ENCLOSURE, REMOVE OUT OF CHASE FIBERGLASS PIPE INSULATION AND RELATED FITTINGS. PIPE INSUALTION SYSTEMS HAVE INTERMITTENT APPLIED ASBESTOS GRAY MASTIC IN THE APPROXIMATE FOLLOWING QUANTITIES; 26 LF OF PIPE INSULATION AND FITTINGS IN ROOM AND 12 LF OF PIPE INSULATION RELATED TO DEMOLITION OF CFU. REFERENCE DRAWING M-401 FOR LOCATIONS OF PIPE TO BE REMOVED
A1
A2
A3
L1
L2
L3
331-1
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
BID DOCUMENTS
A4
1 ADDENDUM 1 7/29/2025
A4
A3
A2 L2L1 L3A1
VISUAL KEY
LIMITS OF NEGATIVE PRESSURE ENCLOSURE(S) WITH APPROPRIATE
THREE STAGE DECON, TWO STAGE LOADOUT, AND NEGATIVE AIR
MACHINES WITH THREE STAGE HEPA FILTRATION ALL IN ACCORDANCE
WITH SPECIFICATIONS. TUBING SHALL BE VENTED TO THE BUILDING
EXTERIOR. EXHAUST TUBING AND OUTFLOW SHALL BE LOCATED SO AS
TO AVOID DISRUPTION TO VA OPERATIONS. COORDINATE EXHAUST
LOCATIONS WITH COR. REFER TO PHASING SHEETS FOR SPECIFIC
PROJECT-WIDE PHASING.
MAINTAIN A MINIMUM OF ½ THE WIDTH OF THE HALLWAYS FOR FREE
ACCESS TO MOVE PATIENTS. COORDINATE WITH THE VA-COR TO ALLOW
FOR ADEQUATE PASSAGE OF PATIENTS WHERE ASPECTS OF THE NPE
e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
FULLY SPRINKLERED
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
/2
2/
:2 3:
A
M
BUILDING 1 - THIRD FLOOR -
ENVIRONMENTAL HAZARDS
CD 10 258JR
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511 HA014
SPUR #: 2207.00
No. REVISION DESCRIPTION DATE
NOT TO SCALE
BUILDING 1 - FOURTH FLOOR
HAZARDOUS MATERIALS KEYNOTES
AN ASBESTOS-CONTAINING GRAY MASTIC EXISTS ON FIBERGLASS LINES AND FITTINGS THROUGHOUT BUILDING. UNLESS OTHERWISE SPECIFIED AVOID DISTURBANCE. ANY WORK IMPACTING THIS MATERIAL MUST BE PERFORMED BY LICENSED ASBESTOS ABATEMENT CONTRACTORS.
AN ASBESTOS-CONTAINING WHITE SINK SOUNDPROOFING MATERIAL IS KNOWN TO EXIST WITHIN BUILDING 1. AVOID ANY WORK LIKELY TO IMPACT SINKS COVERED IN THIS WHITE SINK
SOUNDPROOFING MATERIAL.
WITHIN A NPE, USING MM's, REMOVE NON-ACM 12" BEIGE WITH LONG BROWN STREAK, NON-ACM MASTIC, LEVELING COMPOUND, AND UNDERLYING RESIDUAL ACM BLACK MASTIC. ~97 SF
LBP ON PLASTER CEILINGS. DO NOT DISTURB.ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT CONTRACTOR.
LBP ON METAL STEAM LINES. DO NOT DISTURB.ANY WORK LIKELY TO DISTURB THESE MATERIALS MUST BE PERFORMED BY A LICENSED ABATEMENT CONTRACTOR.
HAZARDOUS MATERIALS ALONG LIKELY ROUTING PATHWAYS ABOVE CEILING TILE. LEAD BASED PAINT ON CONCRETE &/OR PLASTER CEILING. WITHIN A NEGATIVE PRESSURE ENCLOSURE, USING CHEMICAL AND MANUAL METHODS, PERFORM SPOT REMOVAL OF LEAD BASED PAINT AT ANCHOR POINTS. 1 SF EACH LOCATION AT APPROXIMATELY 50 LOCATIONS.
COORDINATE EXACT LOCATIONS AND QUANTITIES WITH GC AND OTHER AFFECTED TRADES.
USING GLOVEBAG METHODS WITHIN A NEGATIVE PRESSURE ENCLOSURE, REMOVE OUT OF CHASE FIBERGLASS PIPE INSULATION AND RELATED FITTINGS. PIPE INSUALTION SYSTEMS HAVE INTERMITTENT APPLIED ASBESTOS GRAY MASTIC IN THE APPROXIMATE FOLLOWING QUANTITIES; 42 LF OF PIPE INSULATION AND FITTINGS IN ROOM AND 12 LF OF PIPE INSULATION RELATED TO DEMOLITION OF CFU. REFERENCE DRAWING M-401 FOR LOCATIONS OF PIPE TO BE REMOVED
A1
A2
A3
L1
L2
L3
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
BID DOCUMENTS
1 ADDENDUM 1 7/29/2025
A4
419-1 A4 A3
VISUAL KEY
LIMITS OF NEGATIVE PRESSURE ENCLOSURE(S) WITH APPROPRIATE
THREE STAGE DECON, TWO STAGE LOADOUT, AND NEGATIVE AIR
MACHINES WITH THREE STAGE HEPA FILTRATION ALL IN ACCORDANCE
WITH SPECIFICATIONS. TUBING SHALL BE VENTED TO THE BUILDING
EXTERIOR. EXHAUST TUBING AND OUTFLOW SHALL BE LOCATED SO AS
TO AVOID DISRUPTION TO VA OPERATIONS. COORDINATE EXHAUST
LOCATIONS WITH COR. REFER TO PHASING SHEETS FOR SPECIFIC
PROJECT-WIDE PHASING.
MAINTAIN A MINIMUM OF ½ THE WIDTH OF THE HALLWAYS FOR FREE
ACCESS TO MOVE PATIENTS. COORDINATE WITH THE VA-COR TO ALLOW
FOR ADEQUATE PASSAGE OF PATIENTS WHERE ASPECTS OF THE NPE
e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
FULLY SPRINKLERED
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
/2
2/
:2 3:
A
M
BUILDING 25 - GROUND FLOOR -
ENVIRONMENTAL HAZARDS
CD 25 258JR
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511 HA250
SPUR #: 2207.00
No. REVISION DESCRIPTION DATE
HAZARDOUS MATERIALS KEYNOTES
KEYNOTE DELETED
AREA OF KNOWN DAMAGED ASBESTOS CONTAINING PIPE INSULATION ABOVE
CEILING TILE. WITHIN A NEGATIVE PRESSURE ENCLOSURE, USING MANUAL
MEANS, REMOVE CONTAMINATED NON-ACM CEILING TILE AND GLOVEBAG
METHOD REMOVE DAMAGED ASBESTOS CONTAINING PIPE/PIPE FITTING
INSULATION. DISPOSE OF CEILING TILE AS ACM WASTE, 32 SF CEILING TILE AND 10
LF OF ACM INSULATION.
WITHIN A NEGATIVE PRESSURE ENCLOSURE, USING MANUAL MEANS, REMOVE
ASBESTOS CONTAINING 12" BEIGE FLOOR TILE AND UNDERLYING ASBESTOS
CONTAINING BLACK MASTIC, 90 SF
AREA OF KNOWN AND/OR PRESUMED ASBESTOS CONTAINING BLACK COATING
ON INSIDE OF EXTERIOR WALL, AND WATERPROOFING BELOW GRADE. WITHIN A
NPE, USING MANUAL MEANS, PROVIDE WALL PENETRATION(S). REFERENCE
MECHANICAL, ELECTRICAL, AND TELECOMMUNICATION DRAWING SETS FOR
DETAILS. NOTE - TELECOMMUNICATION PATHWAYS TO BE LOCATED WITHIN NEW
DUCT BANKS HAVE A SLIGHTLY DIFFERENT ENTRY/EXIT POINT THAN THOSE
INDICATED WITHIN THE CIVIL DRAWING SET. COORDINATE EXACT LOCATIONS AND
QUANTITIES WITH COR, GC, AND OTHER IMPACTED PROFESSIONS AND TRADES.
ESTIMATED 3 SF EACH AT 3 LOCATIONS
WITHIN A NEGATIVE PRESSURE ENCLOSURE, USING MANUAL MEANS, DEMOLISH
EXISTING NON-ACM PLASTER &/OR DRYWALL CHASE WALL TO EXPOSE
UNDERLYING ACM PIPE/FITTING INSULATION. THEN, USING GLOVE BAG METHODS,
REMOVE ACM PIPE/FITTING INSULATION, 120 SF OF NON-ACM PLASTER &/OR
DRYWALL, 25 LF PIPE/FITTING INSULATION
WITHIN A NEGATIVE PRESSURE MINI-ENCLOSURE, USING MANUAL MEANS,
PROVIDE FLOOR PENETRATIONS THROUGH 16" NON-ACM VINYL FLOOR TILE, ACM
GREEN TERRAZZO FLOORING, AND UNDERLYING CONCRETE TO FACILITATE
INSTALLATION OF TELECOM CONDUIT AND CABLE FOR B-PATH RISERS AND
FLOOR PLATE FOR METAL WALL FRAMING. COORDINATE EXACT SIZE AND
PLACEMENT WITH GC, TC, AND OTHER IMPACTED TRADES, 2 SF EACH AT 3
LOCATIONS
DO NOT DISTURB ASBESTOS-CONTAIING 12”X12” CEILING TILE MASTIC DURING
REMOVAL/REPLACEMENT OF EXISTING CABLE TRAY. REUSE OF EXISTING CABLE
TRAY ATTACHMENT POINTS IS REQUIRED IN THIS AREA.
A1
A2
A3
A4
19-25
NOT TO SCALE
BUILDING 25 - GROUND FLOOR
A3
A4
A2
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
N
BID DOCUMENTS
A5
A6
A6A5
A7
1 ADDENDUM 1 7/29/2025
A7
VISUAL KEY
LIMITS OF NEGATIVE PRESSURE ENCLOSURE(S) WITH APPROPRIATE
THREE STAGE DECON, TWO STAGE LOADOUT, AND NEGATIVE AIR
MACHINES WITH THREE STAGE HEPA FILTRATION ALL IN ACCORDANCE
WITH SPECIFICATIONS. TUBING SHALL BE VENTED TO THE BUILDING
EXTERIOR. EXHAUST TUBING AND OUTFLOW SHALL BE LOCATED SO AS
TO AVOID DISRUPTION TO VA OPERATIONS. COORDINATE EXHAUST
LOCATIONS WITH COR. REFER TO PHASING SHEETS FOR SPECIFIC
PROJECT-WIDE PHASING.
MAINTAIN A MINIMUM OF ½ THE WIDTH OF THE HALLWAYS FOR FREE
ACCESS TO MOVE PATIENTS. COORDINATE WITH THE VA-COR TO ALLOW
FOR ADEQUATE PASSAGE OF PATIENTS WHERE ASPECTS OF THE NPE
e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
FULLY SPRINKLERED
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
/2
2/
:2 3:
A
M
BUILDING 25 - FIRST FLOOR -
ENVIRONMENTAL HAZARDS
CD 26 258JR
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511 HA251
SPUR #: 2207.00
No. REVISION DESCRIPTION DATE
HAZARDOUS MATERIALS KEYNOTES
KEYNOTE DELETED
WITHIN A NEGATIVE PRESSURE MINI-ENCLOSURE, USING MANUAL MEANS,
PROVIDE FLOOR PENETRATIONS THROUGH 16" NON-ACM VINYL FLOOR TILE, ACM
GREEN TERRAZZO FLOORING, AND UNDERLYING CONCRETE TO FACILITATE
INSTALLATION OF TELECOM CONDUIT AND CABLE FOR B-PATH RISERS AND
FLOOR PLATE FOR METAL WALL FRAMING. COORDINATE EXACT SIZE AND
PLACEMENT WITH GC, TC, AND OTHER IMPACTED TRADES, 2 SF EACH AT 3
LOCATIONS
A1
NOT TO SCALE
BUILDING 25 - FIRST FLOOR
214-25
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
N
BID DOCUMENTS
A2
A2
1 ADDENDUM 1 7/29/2025
VISUAL KEY
LIMITS OF NEGATIVE PRESSURE ENCLOSURE(S) WITH APPROPRIATE
THREE STAGE DECON, TWO STAGE LOADOUT, AND NEGATIVE AIR
MACHINES WITH THREE STAGE HEPA FILTRATION ALL IN ACCORDANCE
WITH SPECIFICATIONS. TUBING SHALL BE VENTED TO THE BUILDING
EXTERIOR. EXHAUST TUBING AND OUTFLOW SHALL BE LOCATED SO AS
TO AVOID DISRUPTION TO VA OPERATIONS. COORDINATE EXHAUST
LOCATIONS WITH COR. REFER TO PHASING SHEETS FOR SPECIFIC
PROJECT-WIDE PHASING.
MAINTAIN A MINIMUM OF ½ THE WIDTH OF THE HALLWAYS FOR FREE
ACCESS TO MOVE PATIENTS. COORDINATE WITH THE VA-COR TO ALLOW
FOR ADEQUATE PASSAGE OF PATIENTS WHERE ASPECTS OF THE NPE
e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
FULLY SPRINKLERED
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
/2
2/
:2 3:
A
M
BUILDING 25 - SECOND FLOOR -
ENVIRONMENTAL HAZARDS
CD 27 258JR
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511 HA252
SPUR #: 2207.00
No. REVISION DESCRIPTION DATE
NOT TO SCALE
BUILDING 25 - SECOND FLOOR
HAZARDOUS MATERIALS KEYNOTES
KEYNOTE DELETED
WITHIN A NEGATIVE PRESSURE MINI-ENCLOSURE, USING MANUAL MEANS,
PROVIDE FLOOR PENETRATIONS THROUGH 16" NON-ACM VINYL FLOOR TILE, ACM
GREEN TERRAZZO FLOORING, AND UNDERLYING CONCRETE TO FACILITATE
INSTALLATION OF TELECOM CONDUIT AND CABLE FOR B-PATH RISERS AND
FLOOR PLATE FOR METAL WALL FRAMING. COORDINATE EXACT SIZE AND
PLACEMENT WITH GC, TC, AND OTHER IMPACTED TRADES, 2 SF EACH AT 3
LOCATIONS
A1
112-25
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
N
BID DOCUMENTS
A2
A2
1 ADDENDUM 1 7/29/2025
VISUAL KEY
LIMITS OF NEGATIVE PRESSURE ENCLOSURE(S) WITH APPROPRIATE
THREE STAGE DECON, TWO STAGE LOADOUT, AND NEGATIVE AIR
MACHINES WITH THREE STAGE HEPA FILTRATION ALL IN ACCORDANCE
WITH SPECIFICATIONS. TUBING SHALL BE VENTED TO THE BUILDING
EXTERIOR. EXHAUST TUBING AND OUTFLOW SHALL BE LOCATED SO AS
TO AVOID DISRUPTION TO VA OPERATIONS. COORDINATE EXHAUST
LOCATIONS WITH COR. REFER TO PHASING SHEETS FOR SPECIFIC
PROJECT-WIDE PHASING.
MAINTAIN A MINIMUM OF ½ THE WIDTH OF THE HALLWAYS FOR FREE
ACCESS TO MOVE PATIENTS. COORDINATE WITH THE VA-COR TO ALLOW
FOR ADEQUATE PASSAGE OF PATIENTS WHERE ASPECTS OF THE NPE
| 1-HA010 |
| Sheets and Views |
| Model |
| 2-HA011 |
| Sheets and Views |
| Model |
| 3-HA012 |
| Sheets and Views |
| Model |
| 4-HA013 |
| Sheets and Views |
| Model |
| 5-HA014 |
| Sheets and Views |
| Model |
| 20-HA250 |
| Sheets and Views |
| Model |
| 21-HA251 |
| Sheets and Views |
| Model |
| 22-HA252 |
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .