08 - 596-22-700 Drawings 04_Architectural.pdf
PDF 7 MB Posted
- Solicitation number
- 36C77625B0040
About this file
These architectural drawings detail the Electronic Health Record Modernization (EHRM) Infrastructure Upgrades for the Lexington VA Health Care System located at 2250 Leestown Road in Lexington, Kentucky. The comprehensive set of plans covers multiple buildings (Buildings 1, 2, 3, 4, 12, 16, 17, 25, 27, 28, 29, 37, 47, and 48) and includes site plans, floor plans, and detailed architectural modifications for telecommunications rooms, mechanical spaces, and infrastructure improvements.
The drawings specify renovation work including new telecommunications rooms, fiber optic infrastructure upgrades, mechanical equipment replacements, security enhancements, and associated architectural modifications. Key elements include installing new telecommunications racks, creating fiber chase pathways, replacing doors with badge access systems, applying security window films, constructing mechanical and generator blast walls, and updating finishes in various rooms. The project is fully sprinklered and involves precise architectural detailing across multiple buildings, with specific attention to telecommunications infrastructure, security upgrades, and compliance with VA standards.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
28 29
LEESTOWN ROAD
CONTRACTOR
STAGING AREA
LOT A
LOT H
MAIN ENTRANCE
LOT G
LOT B
LOT C
LOT D
LOT D
LOT E
LOT F
LOT F
LOT I
LOT I
ONE-STORY
METAL BARN
52 9
SITE PLAN LEGEND
BUILDINGS IN SCOPE
BUILDING 1: CLINICAL OUTPATIENT ADMIN
BUILDING 2: CANTEEN, FISCAL, ENG, AMM, HR
BUILDING 3: KITCHEN, PHARMACY, WAREHOUSE
BUILDING 4: EDUCATION
BUILDING 12: WAREHOUSE
BUILDING 16: PC CLINICS, POLYTRAUMA
BUILDING 17: CEC, CCHT, AUDIOLOGY, OIT, SPD, LOGISTICS
BUILDING 25: MENTAL HEALTH
BUILDING 27: COMMUNITY LIVING CENTER
BUILDING 28: CHAPEL, EMS, DENTAL, AUDIOLOGY
BUILDING 29: INPATIENT REHAB
BUILDING 37: MR SHOP, LOCK SIGN PAINT SHOP
BUILDING 47: MO SERVICES SHOP
BUILDING 48: GROUNDS TRANSPORTATION
BUILDING 201: COMMUNITY LIVING CENTER BUILDING (SITE FIBER ONLY, REF: CIVIL & TELECOM.)
BUILDING 202: COMMUNITY LIVING CENTER BUILDING (SITE FIBER ONLY, REF: CIVIL & TELECOM.)
BUILDING 204: COMMUNITY LIVING CENTER BUILDING (SITE FIBER ONLY, REF: CIVIL & TELECOM.)
BUILDING 205: COMMUNITY LIVING CENTER BUILDING (SITE FIBER ONLY, REF: CIVIL & TELECOM.)
BUILDING 206: FISHER HOUSE (SITE FIBER ONLY, REF: CIVIL & TELECOM.)
CONTRACTOR PATH OF
TRAVEL
BUILDING NUMBER AND FUNCTION
NEW FIBER TO EXISTING
BUILDING; REF. TELECOM
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :3
P
M
ARCHITECTURAL SITE PLAN
NSM 61 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
AS001
SPUR #: 2207
N
1" = 100'-0"
SITE PLAN1
No. REVISION DESCRIPTION DATE
AE101
AE101
EXISTING
PHONE ROOM
TR
31A
121 SF/ 100 SF
VESTIBULE
31B
CORRIDOR CLG = 7'-2" 2.114
TR
229-1
94 SF/ 100 SF
AE101
AE101
CORRIDOR CLG= 8'-0" 2.114
TR
331-1
87 SF/ 100 SF
AE102
AE102
CORRIDOR CLG = 8'-4" 2.114
TR
419-1
97 SF/ 100 SF
AE102
AE102
CORRIDOR CLG = 7'-7"
AE511
TR
147A-1
134 SF/ 100 SF
AE101
AE101
CORRIDOR CLG = 7'-11" 2.114
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
3. WALL MOUNTED CLEAN AGENT TYPE FIRE EXTINGUISHER REQUIRED WITHIN MCR. CONTRACTOR
TO COORDINATE FINAL LOCATIONS WITH COR AT TIME OF CONSTRUCTION.
4. WALL MOUNTED CARBON DIOXIDE OR CLEAN AGENT TYPE FIRE EXTINGUISHERS REQUIRED
WITHIN 75 FT OF NEW TR. CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH COR AT TIME
OF CONSTRUCTION. EXTINGUISHERS MAY NOT BE LOCATED WITHIN THE TR.
GENERAL OVERALL PLAN NOTES
KEY PLAN
LEESTOWN ROAD
N
AREA FOR NEW DATA OUTLETS, REF: TELECOM
PLAN LEGEND
AREA NOT IN SCOPE
AREA WITHIN THE ARCHITECTRUAL SCOPE
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :3
P
M
BUILDING 1 - REFERENCE PLANS
NSM 62 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
A-101
SPUR #: 2207
N
1" = 20'-0" 1/ AE201
B1 - GROUND LEVEL1
N
1" = 20'-0"
B1 - LEVEL 23
N
1" = 20'-0"
B1 - LEVEL 34
N
1" = 20'-0"
B1 - LEVEL 45
N
1" = 20'-0"
B1 - LEVEL 12
KEYNOTE LEGEND
2.114 EXISTING CHASE TO BE USED FOR FIBER RISER, REF: TELECOM.
TR
24A-3
64 SF/ 100 SF
AE103
AE103
2.115
AE511
TR
220-2
143 SF/ 100 SF
AE102
AE102
C O
R R
ID
O
R C
LG
'-8
AE511
Sim
TR
222A-3
67 SF/ 100 SF
AE103
AE511
Sim
TR
122-2
126 SF/ 100 SF
TR
131A-3
66 SF/ 100 SF
AE102
AE103
AE102
AE103
AE511
Sim
AE511
Sim
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
3. WALL MOUNTED CLEAN AGENT TYPE FIRE EXTINGUISHER REQUIRED WITHIN MCR. CONTRACTOR
TO COORDINATE FINAL LOCATIONS WITH COR AT TIME OF CONSTRUCTION.
4. WALL MOUNTED CARBON DIOXIDE OR CLEAN AGENT TYPE FIRE EXTINGUISHERS REQUIRED
WITHIN 75 FT OF NEW TR. CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH COR AT TIME
OF CONSTRUCTION. EXTINGUISHERS MAY NOT BE LOCATED WITHIN THE TR.
GENERAL OVERALL PLAN NOTES
AREA FOR NEW DATA OUTLETS, REF: TELECOM
PLAN LEGEND
AREA NOT IN SCOPE
AREA WITHIN THE ARCHITECTRUAL SCOPE
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
LEESTOWN ROAD
KEY PLAN
N th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :3
P
M
BUILDINGS 2 & 3 - REFERENCE PLANS
NSM 63 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
A-102
SPUR #: 2207
N
1" = 20'-0"
B2,B3 - GROUND LEVEL1
N
1" = 20'-0"
B2 - LEVEL 22
N
1" = 20'-0"
B3 - LEVEL 24
N
1" = 20'-0"
B2,B3 - LEVEL 13
2 & 3
KEYNOTE LEGEND
2.115 EXISTING SPACE TO BE USED FOR FIBER RISER, REF: TELECOM.
102-4
119 SF/ 100 SF
AE104
AE104
STAGE
AE104
AE104
WAREHOUSE
AREA
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
3. WALL MOUNTED CLEAN AGENT TYPE FIRE EXTINGUISHER REQUIRED WITHIN MCR. CONTRACTOR
TO COORDINATE FINAL LOCATIONS WITH COR AT TIME OF CONSTRUCTION.
4. WALL MOUNTED CARBON DIOXIDE OR CLEAN AGENT TYPE FIRE EXTINGUISHERS REQUIRED
WITHIN 75 FT OF NEW TR. CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH COR AT TIME
OF CONSTRUCTION. EXTINGUISHERS MAY NOT BE LOCATED WITHIN THE TR.
GENERAL OVERALL PLAN NOTES
AREA FOR NEW DATA OUTLETS, REF: TELECOM
PLAN LEGEND
AREA NOT IN SCOPE
AREA WITHIN THE ARCHITECTRUAL SCOPE
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
KEY PLAN
N
LEESTOWN ROAD
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :4
P
M
BUILDINGS 4 & 12 - REFERENCE PLANS
NSM 64 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
A-103
SPUR #: 2207
N
1" = 20'-0"
B4 - LEVEL 11
N
1" = 20'-0"
B12 - LEVEL 12
4 & 12
13C-17
125 SF/ 100 SF
AE106
AE106
AE108
AE108
NEW MCR
22-17
CLOSET
(DEMARC)
13B-17
FIRE CONTROL
PANEL AND
CLEAN AGENT
STORAGE
23-17
CLOSET
24-17
AE511
Sim
TR
217A-17
124 SF/ 100 SF
AE107
AE107
CLOSET
218-17
79 SF/ 100 SF
AE511
CLOSET
6B-16
TR
15-16
111 SF/ 100 SF
AE105
AE105
AE104
AE104
CLOSET
222A-16
82 SF/ 100 SF
TR
207A-16
109 SF/ 100 SF
CONFERENCE
ROOM
207-16
AE106
AE106
AE105
AE105
CLOSET
115B-16
TR
102-16
111 SF/ 100 SF
AE105
AE105
AE105
AE105
CLOSET
126-17
80 SF/ 100 SF
AE107
AE107
TR
125A-17
TRAINING
ROOM
125-17
AE511
Sim
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
3. WALL MOUNTED CLEAN AGENT TYPE FIRE EXTINGUISHER REQUIRED WITHIN MCR. CONTRACTOR
TO COORDINATE FINAL LOCATIONS WITH COR AT TIME OF CONSTRUCTION.
4. WALL MOUNTED CARBON DIOXIDE OR CLEAN AGENT TYPE FIRE EXTINGUISHERS REQUIRED
WITHIN 75 FT OF NEW TR. CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH COR AT TIME
OF CONSTRUCTION. EXTINGUISHERS MAY NOT BE LOCATED WITHIN THE TR.
GENERAL OVERALL PLAN NOTES
AREA FOR NEW DATA OUTLETS, REF: TELECOM
PLAN LEGEND
AREA NOT IN SCOPE
AREA WITHIN THE ARCHITECTRUAL SCOPE
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
LEESTOWN ROAD
KEY PLAN
N th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :4
P
M
BUILDINGS 16 & 17 - REFERENCE PLANS
NSM 65 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
A-104
SPUR #: 2207
N
1" = 20'-0"
B17 - GROUND LEVEL4
N
1" = 20'-0"
B17 - LEVEL 26
N
1" = 20'-0"
B16 - GROUND LEVEL1
N
1" = 20'-0"
B16 - LEVEL 23
N
1" = 20'-0"
B16 - LEVEL 12
N
1" = 20'-0"
B17 - LEVEL 15
16 & 17
19-25
88 SF/ 100 SF
AE109
AE109
AE511
Sim
AE202
GENERATOR
PAD
1-25
TR
214-25
85 SF/ 100 SF
AE109
AE109
AE511
Sim
TR
112-25
87 SF/ 100 SF
AE109
AE109
AE511
Sim
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
3. WALL MOUNTED CLEAN AGENT TYPE FIRE EXTINGUISHER REQUIRED WITHIN MCR. CONTRACTOR
TO COORDINATE FINAL LOCATIONS WITH COR AT TIME OF CONSTRUCTION.
4. WALL MOUNTED CARBON DIOXIDE OR CLEAN AGENT TYPE FIRE EXTINGUISHERS REQUIRED
WITHIN 75 FT OF NEW TR. CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH COR AT TIME
OF CONSTRUCTION. EXTINGUISHERS MAY NOT BE LOCATED WITHIN THE TR.
GENERAL OVERALL PLAN NOTES
AREA FOR NEW DATA OUTLETS, REF: TELECOM
PLAN LEGEND
AREA NOT IN SCOPE
AREA WITHIN THE ARCHITECTRUAL SCOPE
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
N
KEY PLAN
LEESTOWN ROAD
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :4
P
M
BUILDING 25 - REFERENCE PLANS
NSM 66 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
A-105
SPUR #: 2207
N
1" = 20'-0"
B25 - GROUND LEVEL1
N
1" = 20'-0"
B25 - LEVEL 23
N
1" = 20'-0"
B25 - LEVEL 12
1A-28
120 SF/ 100 SF
AE111
AE111
2.114
TR
247-28
107 SF/ 100 SF
AE111
AE111
2.114
TR
2F-27
135 SF/ 100 SF
TR
16D-27
134 SF/ 100 SF
AE110
AE110
TR
236A-27
135 SF/ 100 SF
TR
217A-27
133 SF/ 100 SF
AE110
AE110
TR
136A-27
134 SF/ 100 SF
TR
117A-27
134 SF/ 100 SF
AE110
AE110
TR
156-28
111 SF/ 100 SF
AE111
AE111
2.114
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
3. WALL MOUNTED CLEAN AGENT TYPE FIRE EXTINGUISHER REQUIRED WITHIN MCR. CONTRACTOR
TO COORDINATE FINAL LOCATIONS WITH COR AT TIME OF CONSTRUCTION.
4. WALL MOUNTED CARBON DIOXIDE OR CLEAN AGENT TYPE FIRE EXTINGUISHERS REQUIRED
WITHIN 75 FT OF NEW TR. CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH COR AT TIME
OF CONSTRUCTION. EXTINGUISHERS MAY NOT BE LOCATED WITHIN THE TR.
GENERAL OVERALL PLAN NOTES
AREA FOR NEW DATA OUTLETS, REF: TELECOM
PLAN LEGEND
AREA NOT IN SCOPE
AREA WITHIN THE ARCHITECTRUAL SCOPE
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
N
KEY PLAN
LEESTOWN ROAD
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :5
P
M
BUILDINGS 27 & 28 - REFERENCE PLANS
NSM 67 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
A-106
SPUR #: 2207
N
1" = 20'-0"
B28 - GROUND LEVEL4
N
1" = 20'-0"
B28 - LEVEL 26
N
1" = 20'-0"
B27 - GROUND LEVEL1
N
1" = 20'-0"
B27 - LEVEL 23
N
1" = 20'-0"
B27 - LEVEL 12
N
1" = 20'-0"
B28 - LEVEL 15
27 & 28
KEYNOTE LEGEND
2.114 EXISTING CHASE TO BE USED FOR FIBER RISER, REF: TELECOM.
CLOSET
21-29
62 SF/ 100 SF
AE112
AE112
TR
19B-29
144 SF/ 100 SF
HOUSEKEEPING
STORAGE
19-29
AE511
Sim
TR
239A-29
60 SF/ 100 SF
AE113
AE511
Sim
CLOSET
134A-29
58 SF/ 100 SF
AE112
AE112
PROGRAM
MANAGER
OFFICE
135-29
TR
135A-29
129 SF/ 100 SF
AE511
Sim
AE113
AE113
SHOP
2-47
AE113
AE113
SERVICE
2-48
AE113
AE113
WORK SHOP
8-37
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
3. WALL MOUNTED CLEAN AGENT TYPE FIRE EXTINGUISHER REQUIRED WITHIN MCR. CONTRACTOR
TO COORDINATE FINAL LOCATIONS WITH COR AT TIME OF CONSTRUCTION.
4. WALL MOUNTED CARBON DIOXIDE OR CLEAN AGENT TYPE FIRE EXTINGUISHERS REQUIRED
WITHIN 75 FT OF NEW TR. CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH COR AT TIME
OF CONSTRUCTION. EXTINGUISHERS MAY NOT BE LOCATED WITHIN THE TR.
GENERAL OVERALL PLAN NOTES
AREA FOR NEW DATA OUTLETS, REF: TELECOM
PLAN LEGEND
AREA NOT IN SCOPE
AREA WITHIN THE ARCHITECTRUAL SCOPE
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
N
KEY PLAN
LEESTOWN ROAD
N th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :5
P
M
BUILDINGS 29, 37, 47, & 48 - REFERENCE
PLANS
NSM 68 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
A-107
SPUR #: 2207
N
1" = 20'-0"
B29 - GROUND LEVEL1
N
1" = 20'-0"
B29 - LEVEL 23
N
1" = 20'-0"
B29 - LEVEL 12
N
1" = 20'-0"
B47 - LEVEL 15
N
1" = 20'-0"
B48 - LEVEL 16
29, 37, 47, & 48
N
1" = 20'-0"
B37 - LEVEL 14
147A-1
134 SF/ 100 SF
2.68
2.85
2.80
12'-0"
2.90
2.91
'-5
'-3
8' -1
/2
4'
-3
1' -2
'-4
/2
2'-5"7'-2"2'-5"
11'-3 1/2" 1'-0"
'-9
EXISTING PHONE ROOM
2.80
2.98
1' -4
/2
4'
-5
1'-3 1/2"
2.90
'-0
13'-7"
1'-6" 10'-3" 10" 1'-0"
13'-7"
'-4
/2
1/ 2"
7"
'-9
EXISTING RAISED FLOOR TO REMAIN
2.66
EXISTING
PHONE ROOM
TR
31A
121 SF/ 100 SF
31-1
A
-1
9.32
9.71
9.72 6.586.58
6.58
D3
D3
'-0
5' -7
1'-3 1/2"
3.16
26.12 26.11
'-0
ALIGN
23.07 23.0723.0723.07
23.07
31B-1
3'-9 1/2"3'-9 1/2"
3' -0
/2
3'
-0
/2
7" 9'
-5
11'-3 1/2" 1'-0"
13'-7"
4' -4
/2
1'
-4
/2
5' -9
'-9
ALIGN
1'-6" 10'-3"
13'-7"
27.0127.01
4' -1
1/
2"
1/ 2"
5' -9
'-9
VESTIBULE
31B
EXISTING RAISED FLOOR TO REMAIN
4' -5
5" 1'-0" 5" 21.02
8.111
18'-8 1/2"
4' -0
TR
147A-1
134 SF/ 100 SF
7A
-1
6.58
6.58 9.32 9.71
26.11
26.12
3'-0"4'-9"
4' -6
/2
3'
-0
27.01 27.01
12'-0"
'-5
'-3
8' -1
/2
4'
-3
1' -2
'-4
/2
2'-5"7'-2"2'-5" 21.02
9'-7"
8'-10"
EXISTING PHONE ROOM
11'-3 1/2" 1'-0"
'-9
5' -9
/2
4'
-2
1' -4
/2
4'
-5
1'-10"10'-3"1'-6"
1'-3 1/2"
13'-7"
9' -7
/2
4'
-9
7"
1/ 2"
'-9
13'-7"
TR
31A
1'-3 1/2"
23.06
11'-2"
13'-2"
9' -9
/2
5'-11"EQEQ
13'-2"
9' -9
/2
9.75
E Q
5' -9
E
Q
TR
147A-1
2.72
12'-9"
2.66
2.91
12'-0"
'-5
'-3
8' -1
/2
4'
-3
1' -2
'-4
/2
2'-5"7'-2"2'-5"
2.68
2.85
TR
147A-1 12'-9"
9.75
23.06
2' -0
3'
-6
5' -9
12'-0"
1' -2
'-5
2'-5" 2'-5"4'-6" 2'-8"
2' -0
2'-5"
12'-0"
'-5
5'-1"6'-11"
26.15
TR
229-1
94 SF/ 100 SF
2.682.85
2.80
2.90
2.91
1'-5 1/2"7'-1 1/2"
8'-7"
'-5
1' -1
/2
'-3
/2
TR
229-1
94 SF/ 100 SF
229-1
9.32
6.58
26.116.58
1'-5 1/2"7'-1 1/2"
8'-7"
'-5
1' -1
/2
'-3
/2
26.12
3'-0"
3' -6
/2
3'
-0
1'-4"
9.71
27.0127.01
21.02
TR
229-1
2.72
11'-11"
2.66
2.91
1'-5 1/2"7'-1 1/2"
8'-7"
'-5
1' -1
/2
'-3
/2
2.68
2.85
TR
229-1
9.75
11'-11"
23.06
1' -6
6'
-3
/2
2' -6
3'-1"5'-6"
8'-7"
8'-7"
1'-5 1/2"3'-7 1/2"3'-6"
1' -1
/2
'-5
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. AS DEFINED BY INFECTION CONTROL CRITERIA FOR SCOPE OF WORK RELEVANT TO EACH
TELECOMMUNICATION ROOM, DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER
NEGATIVE PRESSURE UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OR AREA HAS BEEN
INSPECTED BY THE VA SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN
FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO
EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE MECHANICAL
AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO ROOMS OUTSIDE
OF SCOPE WITH OWNER
GENERAL DEMOLITION NOTES
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. CONTRACTOR TO MAINTAIN THE INTEGRITY OF FIRE BARRIERS AND SMOKE PARTITIONS.
FIRESTOP AS REQUIRED PER CODE.
3. ALL WALLS IN TELECOMMUNICATIONS ROOMS (TR) TO GO TO DECK. IF EXISTING WALL DOES NOT
CURRENTLY GO TO DECK, CONTRACTOR TO EXTEND WALL SYSTEM UP TO EXISTING STRUCTURE
ABOVE PRIOR TO CAULKING. MAINTAIN EXISTING FIRE RATING.
4. ALL NEW CONSTRUCTION WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNO.
5. ALL EXISTING WALLS ARE DIMENSIONED TO FACE OF EXISTING FINISH, UNO.
6. ALL EXISTING GLAZING LOCATED IN EXTERIOR WALLS WITHIN EXISTING AND NEW TELECOM
ROOMS SHALL RECEIVE 15-MINUTE FORCED INTRUSION RESISTANT FILM & CONTACT SENSORS
TIED TO THE SECURITY CONTROL CENTER.
GENERAL PLAN NOTES
1. CEILINGS IN ALL TR'S ARE TO BE OPEN TO BOTTOM OF DECK, UNLESS NOTED OTHERWISE.
2. ALL CEILING HEIGHTS ARE NOTED ON THE PLAN.
3. REFER TO ROOM FINISH SHEDULE FOR CEILING PAINT COLOR.
4. ALL FIXTURES IN DEMOLISHED CEILINGS ARE TO FIRST BE REMOVED AND RETURNED TO OWNER, UNO.
5. EXISTING SPRINKLERS IN NEW / EXPANDED TRS TO BE REPLACED WITH NEW UPRIGHT SPRINKLERS AT THE TIME THE CEILING IS REMOVED IN ORDER TO MAINTAIN SPRINKLER PROTECTION WITHIN THE
CONSTRUCTION AREA.
GENERAL REFLECTED CEILING PLAN NOTES
EXISTING DOOR & FRAME.
REF: KEYNOTES FOR
DEMOLITION NOTES
DEMOLITION & NEW FLOOR PLAN LEGEND
AREA NOT IN CONTRACT
EXISTING WALL TO BE
DEMOLISHED IN ITS ENTIRETY
EXISTING WALL TO REMAIN
& PROTECT
EXISTING DOOR & FRAME TO
REMAIN AND PROTECT
NEW DOOR & FRAME
APPLICATION.
REF: DOOR SCHEDULE
EXISTING 1 HOUR FIRE EXISTING 2 HOUR FIRE
SMOKE PARTITION/BARRIER
EXISTING 2' x 2' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING GYPSUM BOARD
CEILING TO BE DEMOLISHED
EXISTING 2 x 2 LIGHT FIXTURE
TO BE DEMOLISHED
EXISTING 2 x 4 LIGHT
FIXTURE TO BE DEMOLISHED
EXISTING 2' x 4' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING RETURN AIR GRILLE
TO BE DEMOLISHED
EXISTING SUPPLY AIR
DIFFUSER TO BE DEMOLISHED
EXISTING PENDANT LIGHT TO
BE REMOVED
DEMOLITION REFLECTED CEILING PLAN LEGEND
2' x 2' ACOUSTICAL CEILING
CEILING HEIGHT, ABOVE
FINISH FLOOR
00'-00"
REFLECTED CEILING PLAN LEGEND
2' x 4' LIGHT FIXTURE
RE: ELECTRICAL
SUSPENDED LIGHT FIXTURE
RE: ELECTRICAL
SUPPLY AIR DIFFUSER
2' x 2' LIGHT FIXTURE
RE: ELECTRICAL
RETURN AIR GRILLE
RETURN AIR GRILLE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :5
P
M
BUILDING 1 - ENLARGED PLANS
NSM 69 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
AE101
SPUR #: 2207
N
1/4" = 1'-0" 2/ A-101
B1 - LEVEL 1 - 147A-1 - DEMO PLAN5
KEYNOTE LEGEND
2.66 DEMOLISH EXISTING MECHANICAL EQUIPMENT; REF: MECHANICAL.
2.68 REMOVE EXISTING EQUIPMENT ON WALL AND SALVAGE FOR REUSE. DEMOLISH EXISTING WALL
MOUNTED PLYWOOD.
2.72 EXISTING CEILING OPEN TO CONCRETE STRUCTURE ABOVE.
2.80 DEMOLISH EXISTING FLOORING AND BASE TO EXTENTS INDICATED; CLEAN & PREPARE SUB-FLOOR
SURFACE FOR NEW FLOORING.
2.85 REMOVE EXISTING EQUIPMENT ON WALL AND SALVAGE FOR REUSE. DEMOLISH EXISTING WALL
MOUNTED PEG BOARD.
2.90 EXISTING TR EQUIPMENT TO BE REMOVED. REF: TELECOM.
2.91 EXISTING DUCTWORK TO REMAIN. REF: MECHANICAL.
2.98 DEMOLISH EXISTING PORTION OF STEP TO EXTENTS INDICATED.
3.16 NEW CONCRETE PAD. REF: STRUCTURAL, MECHANICAL, AND ELECTRICAL.
6.58 3/4" FIRE RATED PLYWOOD (4X8) MOUNTED 18" FROM FLOOR, PAINTED. REF: ROOM FINISH SCHEDULE.
8.111 NEW DOOR SILL AT EXISTING RAISED FLOOR HEIGHT. F.V.
9.32 NEW FLOOR FINISH TO BE INSTALLED. REF: FINISH SCHEDULE
9.71 PATCH AND REPAIR EXISTING WALLS AFFECTED BY DEMOLITION WORK. FIRE CAULK AND SEAL
PENETRATIONS AS REQUIRED.
9.72 PATCH AND REPAIR EXISTING WALLS AFFECTED BY NEW EQUIPMENT AND CABLE INSTALLATION. FIRE
CAULK AND SEAL PENETRATIONS AS REQUIRED.
9.75 PAINT UNDERSIDE OF STRUCTURE. REF: FINISH SCHEDULE FOR ADDITIONAL INFORMATION.
21.02 CONTRACTOR TO INSTALL NEW FIRE EXTINGUISHER CABINET WITH CARBON DIOXIDE OR CLEAN AGENT TYPE FIRE EXTINGUISHER WITHIN 75 FT OF TR. FINAL LOCATION TO BE COORDINATED WITH COR AT
TIME OF CONSTRUCTION. DO NOT LOCATE FIRE EXTINGUISHER WITHIN THE TR.
23.06 DUCTLESS SPLIT INDOOR UNIT. REF: MECHANICAL
23.07 OUTDOOR CONDENSING UNIT. REF: MECHANICAL
26.11 ELECTRICAL PANEL. REF: ELECTRICAL.
26.12 GROUND BAR. REF: ELECTRICAL.
26.15 MOUNT LIGHT FIXTURES BELOW DUCTWORK, 9'-0" AFF. CONTRACTOR TO FIELD VERIFY THAT LIGHT
FIXTURE DOES NOT CONFLICT WITH EXISTING CONDITIONS.
27.01 TELECOMMUNICATIONS RACK, REF: TELECOM.
N
1/4" = 1'-0" 1/ A-101
B1 - GROUND LEVEL - 31-1 - DEMO PLAN1
N
1/4" = 1'-0" 1/ A-101
B1 - GROUND LEVEL - 31-1 - FLOOR PLAN2
N
1/4" = 1'-0" 2/ A-101
B1 - LEVEL 1 - 147A-1 - FLOOR PLAN6
N
1/4" = 1'-0" 1/ AE201
B1 - GROUND LEVEL - 31-1 - DEMO RCP3
N
1/4" = 1'-0" 1/ AE201
B1 - GROUND LEVEL - 31-1 - RCP4
N
1/4" = 1'-0"
B1 - LEVEL 1 - 147A-1 - DEMO RCP7
N
1/4" = 1'-0"
B1 - LEVEL 1 - 147A-1 - RCP8
N
1/4" = 1'-0" 3/ A-101
B1 - LEVEL 2 - 229-1 - DEMO PLAN9
N
1/4" = 1'-0" 3/ A-101
B1 - LEVEL 2 - 229-1 - FLOOR PLAN10
N
1/4" = 1'-0"
B1 - LEVEL 2 - 229-1 - DEMO RCP11
N
1/4" = 1'-0"
B1 - LEVEL 2 - 229-1 - RCP12
419-1
97 SF/ 100 SF
2.682.85 2.80
8'-7"
'-4
2.90
2.91
TR
122-2
126 SF/ 100 SF
2.80
2.68
2.85
12'-10"
'-3
2.90
7' -7
1'
-1 0"
1'-1"10"10'-11"
TR
419-1
97 SF/ 100 SF
419-1
6.58
9.32 9.71
26.12
26.11
6.58
3'-0"3'-6"
4' -0
3'
-7
/2
8'-7"
'-4
27.01
21.02
TR
122-2
126 SF/ 100 SF 122-2
9.32
9.71
26.12 26.11
6.58
6.58
1'-1"10"10'-11"
12'-10"
'-3
3' -0
3'
-0
4'-7 1/2" 4'-6"
7' -7
1'
-1 0"
27.01
27.01
26.11
21.02
TR
419-1
2.72
2.66
11'-4"
2.91
8'-7"
'-4
"2.682.85
TR
419-1 11'-4"
9.75
23.06
8'-7"
'-4
2' -7
3'
-0
/2
5' -8
/2
5'-4"3'-3"
3'-3" 5'-4"
8'-7"
TR
122-2 2.72
11'-9"
2.66
1'-1"10"10'-11"
12'-10"
'-3
1' -1
0"
7'
-7
2.68
2.85TR
122-2
11'-9"
9.75
23.06
12'-10"
'-3
5'-10"EQ EQ
E Q
E Q
TR
331-1
87 SF/ 100 SF
2.68
2.85
2.80
1'-3"6'-11"
8'-2"
'-1
1'
-0
'-1
2.90
2.91
TR
331-1
87 SF/ 100 SF
331-1
6.58
6.58
9.32 9.71
26.11
26.12
1'-3"6'-11"
8'-2"
'-1
1'
-0
'-1
3'-1"3'-0"
3' -4
3' -0
27.01
21.02
6.58
TR
331-1 2.72
2.91
2.66
12'-3"
1'-3"6'-11"
8'-2"
'-1
1'
-0
'-1
2.68
2.85
TR
331-1
9.75
23.06
12'-3"
8'-2"
2' -5
5'
-8
2' -0
4'-9" 3'-5"
1' -0
'-1
TR
220-2
143 SF/ 100 SF
2.68
2.85
1'-0"3'-9"9'-11"
14'-8"
'-3
2.90
7' -1
1/
2" 1'
-0
1' -4
/2
2.80
TR
220-2
143 SF/ 100 SF
220-2
9.71
9.32
26.12
26.11
9'-11" 3'-9" 1'-0"
14'-8"
'-3
1' -4
/2
1'
-0
7' -1
1/
2"
6.58
6.58
3' -0
3'
-5
/2
3'-6" 6'-11 1/2"
27.0127.01
21.02
TR
220-2 2.72
11'-9"
2.66
2.91
1' -0
1'
-4
/2
7' -1
1/
2"
'-3
9'-11" 3'-9" 1'-0"
14'-8"
2.68
2.68
TR
220-2 9.75
23.06
11'-9"
'-3
2' -1
/2
6'
-6
1' -7
/2
1'-0"3'-9"4'-3 1/2"5'-7 1/2"
14'-8"
'-3
1' -4
/2
1'
-0
7' -1
1/
2"
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. AS DEFINED BY INFECTION CONTROL CRITERIA FOR SCOPE OF WORK RELEVANT TO EACH
TELECOMMUNICATION ROOM, DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER
NEGATIVE PRESSURE UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OR AREA HAS BEEN
INSPECTED BY THE VA SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN
FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO
EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE MECHANICAL
AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO ROOMS OUTSIDE
OF SCOPE WITH OWNER
GENERAL DEMOLITION NOTES
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. CONTRACTOR TO MAINTAIN THE INTEGRITY OF FIRE BARRIERS AND SMOKE PARTITIONS.
FIRESTOP AS REQUIRED PER CODE.
3. ALL WALLS IN TELECOMMUNICATIONS ROOMS (TR) TO GO TO DECK. IF EXISTING WALL DOES NOT
CURRENTLY GO TO DECK, CONTRACTOR TO EXTEND WALL SYSTEM UP TO EXISTING STRUCTURE
ABOVE PRIOR TO CAULKING. MAINTAIN EXISTING FIRE RATING.
4. ALL NEW CONSTRUCTION WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNO.
5. ALL EXISTING WALLS ARE DIMENSIONED TO FACE OF EXISTING FINISH, UNO.
6. ALL EXISTING GLAZING LOCATED IN EXTERIOR WALLS WITHIN EXISTING AND NEW TELECOM
ROOMS SHALL RECEIVE 15-MINUTE FORCED INTRUSION RESISTANT FILM & CONTACT SENSORS
TIED TO THE SECURITY CONTROL CENTER.
GENERAL PLAN NOTES
1. CEILINGS IN ALL TR'S ARE TO BE OPEN TO BOTTOM OF DECK, UNLESS NOTED OTHERWISE.
2. ALL CEILING HEIGHTS ARE NOTED ON THE PLAN.
3. REFER TO ROOM FINISH SHEDULE FOR CEILING PAINT COLOR.
4. ALL FIXTURES IN DEMOLISHED CEILINGS ARE TO FIRST BE REMOVED AND RETURNED TO OWNER, UNO.
5. EXISTING SPRINKLERS IN NEW / EXPANDED TRS TO BE REPLACED WITH NEW UPRIGHT SPRINKLERS AT THE TIME THE CEILING IS REMOVED IN ORDER TO MAINTAIN SPRINKLER PROTECTION WITHIN THE
CONSTRUCTION AREA.
GENERAL REFLECTED CEILING PLAN NOTES
EXISTING DOOR & FRAME.
REF: KEYNOTES FOR
DEMOLITION NOTES
DEMOLITION & NEW FLOOR PLAN LEGEND
AREA NOT IN CONTRACT
EXISTING WALL TO BE
DEMOLISHED IN ITS ENTIRETY
EXISTING WALL TO REMAIN
& PROTECT
EXISTING DOOR & FRAME TO
REMAIN AND PROTECT
NEW DOOR & FRAME
APPLICATION.
REF: DOOR SCHEDULE
EXISTING 1 HOUR FIRE EXISTING 2 HOUR FIRE
SMOKE PARTITION/BARRIER
EXISTING 2' x 2' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING GYPSUM BOARD
CEILING TO BE DEMOLISHED
EXISTING 2 x 2 LIGHT FIXTURE
TO BE DEMOLISHED
EXISTING 2 x 4 LIGHT
FIXTURE TO BE DEMOLISHED
EXISTING 2' x 4' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING RETURN AIR GRILLE
TO BE DEMOLISHED
EXISTING SUPPLY AIR
DIFFUSER TO BE DEMOLISHED
EXISTING PENDANT LIGHT TO
BE REMOVED
DEMOLITION REFLECTED CEILING PLAN LEGEND
2' x 2' ACOUSTICAL CEILING
CEILING HEIGHT, ABOVE
FINISH FLOOR
00'-00"
REFLECTED CEILING PLAN LEGEND
2' x 4' LIGHT FIXTURE
RE: ELECTRICAL
SUSPENDED LIGHT FIXTURE
RE: ELECTRICAL
SUPPLY AIR DIFFUSER
2' x 2' LIGHT FIXTURE
RE: ELECTRICAL
RETURN AIR GRILLE
RETURN AIR GRILLE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:2 :0
P
M
BUILDINGS 1 & 2 - ENLARGED PLANS
NSM 70 258AJS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES LEXINGTON, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
AE102
SPUR #: 2207
1 & 2
KEYNOTE LEGEND
2.66 DEMOLISH EXISTING MECHANICAL EQUIPMENT; REF: MECHANICAL.
2.68 REMOVE EXISTING EQUIPMENT ON WALL AND SALVAGE FOR REUSE. DEMOLISH EXISTING WALL
MOUNTED PLYWOOD.
2.72 EXISTING CEILING OPEN TO CONCRETE STRUCTURE ABOVE.
2.80 DEMOLISH EXISTING FLOORING AND BASE TO EXTENTS INDICATED; CLEAN & PREPARE
SUB-FLOOR SURFACE FOR NEW FLOORING.
2.85 REMOVE EXISTING EQUIPMENT ON WALL AND SALVAGE FOR REUSE. DEMOLISH EXISTING WALL
MOUNTED PEG BOARD.
2.90 EXISTING TR EQUIPMENT TO BE REMOVED. REF: TELECOM.
2.91 EXISTING DUCTWORK TO REMAIN. REF: MECHANICAL.
6.58 3/4" FIRE RATED PLYWOOD (4X8) MOUNTED 18" FROM FLOOR, PAINTED. REF: ROOM FINISH
SCHEDULE.
9.32 NEW FLOOR FINISH TO BE INSTALLED. REF: FINISH SCHEDULE
9.71 PATCH AND REPAIR EXISTING WALLS AFFECTED BY DEMOLITION WORK. FIRE CAULK AND SEAL
PENETRATIONS AS REQUIRED.
9.75 PAINT UNDERSIDE OF STRUCTURE. REF: FINISH SCHEDULE FOR ADDITIONAL INFORMATION.
21.02 CONTRACTOR TO INSTALL NEW FIRE EXTINGUISHER CABINET WITH CARBON DIOXIDE OR CLEAN AGENT TYPE FIRE EXTINGUISHER WITHIN 75 FT OF TR. FINAL LOCATION TO BE COORDINATED
WITH COR AT TIME OF CONSTRUCTION. DO NOT LOCATE FIRE EXTINGUISHER WITHIN THE TR.
23.06 DUCTLESS SPLIT INDOOR UNIT. REF: MECHANICAL
26.11 ELECTRICAL PANEL. REF: ELECTRICAL.
26.12 GROUND BAR. REF: ELECTRICAL.
27.01 TELECOMMUNICATIONS RACK, REF: TELECOM.
N
1/4" = 1'-0" 5/ A-101
B1 - LEVEL 4 - 419-1 - DEMO PLAN5
N
1/4" = 1'-0" 3/ A-102
B2 - LEVEL 1 - 122-2 - DEMO PLAN9
N
1/4" = 1'-0" 5/ A-101
B1 - LEVEL 4 - 419-1 - FLOOR PLAN6
N
1/4" = 1'-0" 3/ A-102
B2 - LEVEL 1 - 122-2 - FLOOR PLAN10
N
1/4" = 1'-0"
B1 - LEVEL 4 - 419-1 - DEMO RCP7
N
1/4" = 1'-0"
B1 - LEVEL 4 - 419-1 - RCP8
N
1/4" = 1'-0"
B2 - LEVEL 1 - 122-2 - DEMO RCP11
N
1/4" = 1'-0"
B2 - LEVEL 1 - 122-2 - RCP12
N
1/4" = 1'-0" 4/ A-101
B1 - LEVEL 3 - 331-1 - DEMO PLAN1
N
1/4" = 1'-0" 4/ A-101
B1 - LEVEL 3 - 331-1 - FLOOR PLAN2
N
1/4" = 1'-0"
B1 - LEVEL 3 - 331-1 - DEMO RCP3
N
1/4" = 1'-0"
B1 - LEVEL 3 - 331-1 - RCP4
N
1/4" = 1'-0" 2/ A-102
B2 - LEVEL 2 - 220-2 - DEMO PLAN13
N
1/4" = 1'-0" 2/ A-102
B2 - LEVEL 2 - 220-2 - FLOOR PLAN14
N
1/4" = 1'-0"
B2 - LEVEL 2 - 220-2 - DEMO RCP15
N
1/4" = 1'-0"
B2 - LEVEL 2 - 220-2 - RCP16
131A-3
66 SF/ 100 SF
1A
-3
5'-1 1/2" 1'-8"
6'-9 1/2"
7" 9'
-4
9' -1
1"
3' -0
3' -7
/2
3'-0"
6.58
6.58
27.01
9.71
9.32
21.02
26.11
26.12
1'-10 1/2"
TR
222A-3
67 SF/ 100 SF
2A
-3 9' -4
7"
9' -1
1"
1'-8"5'-1 1/2"
6'-9 1/2"
3' -0
3'
-7
/2
1'-9"
6.58
6.58
27.01 3'-0"
21.02 26.11
26.12
TR
24A-3
64 SF/ 100 SF
A-3
9' -1
1"
1'-4"5'-2"
6'-6"
1'-5 1/2"
3' -0
3'
-7
/2
7" 9'
-4
6.58
6.58
9.71
9.32
27.01
21.02
3'-0 1/2"
26.11
26.12
4'-8"
'-1
1"
26.11
23.07
23.07
23.07
26.11
26.11
3.16
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. AS DEFINED BY INFECTION CONTROL CRITERIA FOR SCOPE OF WORK RELEVANT TO EACH
TELECOMMUNICATION ROOM, DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER
NEGATIVE PRESSURE UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OR AREA HAS BEEN
INSPECTED BY THE VA SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN
FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO
EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE MECHANICAL
AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO ROOMS OUTSIDE
OF SCOPE WITH OWNER
GENERAL DEMOLITION NOTES
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. CONTRACTOR TO MAINTAIN THE INTEGRITY OF FIRE BARRIERS AND SMOKE PARTITIONS.
FIRESTOP AS REQUIRED PER CODE.
3. ALL WALLS IN TELECOMMUNICATIONS ROOMS (TR) TO GO TO DECK. IF EXISTING WALL DOES NOT
CURRENTLY GO TO DECK, CONTRACTOR TO EXTEND WALL SYSTEM UP TO EXISTING STRUCTURE
ABOVE PRIOR TO CAULKING. MAINTAIN EXISTING FIRE RATING.
4. ALL NEW CONSTRUCTION WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNO.
5. ALL EXISTING WALLS ARE DIMENSIONED TO FACE OF EXISTING FINISH, UNO.
6. ALL EXISTING GLAZING LOCATED IN EXTERIOR WALLS WITHIN EXISTING AND NEW TELECOM
ROOMS SHALL RECEIVE 15-MINUTE FORCED INTRUSION RESISTANT FILM & CONTACT SENSORS
TIED TO THE SECURITY CONTROL CENTER.
GENERAL PLAN NOTES
1. CEILINGS IN ALL TR'S ARE TO BE OPEN TO BOTTOM OF DECK, UNLESS NOTED OTHERWISE.
2. ALL CEILING HEIGHTS ARE NOTED ON THE PLAN.
3. REFER TO ROOM FINISH SHEDULE FOR CEILING PAINT COLOR.
4. ALL FIXTURES IN DEMOLISHED CEILINGS ARE TO FIRST BE REMOVED AND RETURNED TO OWNER, UNO.
5. EXISTING SPRINKLERS IN NEW / EXPANDED TRS TO BE REPLACED WITH NEW UPRIGHT SPRINKLERS AT THE TIME THE CEILING IS REMOVED IN ORDER TO MAINTAIN SPRINKLER PROTECTION WITHIN THE
CONSTRUCTION AREA.
GENERAL REFLECTED CEILING PLAN NOTES
EXISTING DOOR & FRAME.
REF: KEYNOTES FOR
DEMOLITION NOTES
DEMOLITION & NEW FLOOR PLAN LEGEND
AREA NOT IN CONTRACT
EXISTING WALL TO BE
DEMOLISHED IN ITS ENTIRETY
EXISTING WALL TO REMAIN
& PROTECT
EXISTING DOOR & FRAME TO
REMAIN AND PROTECT
NEW DOOR & FRAME
APPLICATION.
REF: DOOR SCHEDULE
EXISTING 1 HOUR FIRE EXISTING 2 HOUR FIRE
SMOKE PARTITION/BARRIER
EXISTING 2' x 2' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING GYPSUM BOARD
CEILING TO BE DEMOLISHED
EXISTING 2 x 2 LIGHT FIXTURE
TO BE DEMOLISHED
EXISTING 2 x 4 LIGHT
FIXTURE TO BE DEMOLISHED
EXISTING 2' x 4' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING RETURN AIR GRILLE
TO BE DEMOLISHED
EXISTING SUPPLY AIR
DIFFUSER TO BE DEMOLISHED
EXISTING PENDANT LIGHT TO
BE REMOVED
DEMOLITION REFLECTED CEILING PLAN LEGEND
2' x 2' ACOUSTICAL CEILING
CEILING HEIGHT, ABOVE
FINISH FLOOR
00'-00"
REFLECTED CEILING PLAN LEGEND
2' x 4' LIGHT FIXTURE
RE: ELECTRICAL
SUSPENDED LIGHT FIXTURE
RE: ELECTRICAL
SUPPLY AIR DIFFUSER
2' x 2' LIGHT FIXTURE
RE: ELECTRICAL
RETURN AIR GRILLE
RETURN AIR GRILLE
2.92
1'-4"5'-2"
6'-6"
9' -4
7"
2.109
2.90
2.85 2.68
2.68
9' -1
1"
TR
24A-3
64 SF/ 100 SF
TR
24A-3
64 SF/ 100 SF
9' -1
1"
1'-4"5'-2"
6'-6"
7" 9'
-4 "2.72
11'-1" 2.66
2.682.68
2.85 2.68
TR
24A-3
64 SF/ 100 SF
9.75
9' -1
1"
1'-4"5'-2"
6'-6"
7" 1'
-6
6' -4
1'
-6
2'-6"4'-0 1/2"
6'-6 1/2"
11'-1"
23.06
26.11
TR
131A-3
66 SF/ 100 SF
2.66
2.72
12'-7"
5'-1 1/2" 1'-8"
6'-9 1/2"
7" 9'
-4
9' -1
1"
2.68
2.85
TR
131A-3
66 SF/ 100 SF
1' -6
1'
-6
7" 6'
-4
9' -1
1"
2'-10 1/2"3'-11 1/2"
6'-10"
5'-1 1/2" 1'-8"
6'-9 1/2"
9.75
12'-7"
23.06
26.11
TR
131A-3
66 SF/ 100 SF
2.92
2.68
2.85
2.90
5'-1 1/2" 1'-8"
6'-9 1/2"
7" 9'
-4
9' -1
1"
5'-1 1/2" 1'-8"
2.92
TR
222A-3
2.68
2.85
2.90
6'-9 1/2"
9' -4
7"
9' -1
1"
TR
222A-3
2.66
9' -4
7"
9' -1
1"
1'-8"5'-1 1/2"
6'-9 1/2"
2.72
9'-5"
2.68
2.85
TR
222A-3
7"
9' -1
1"
1'-8"5'-1 1/2"
6'-9 1/2"
9.75
1' -6
6'
-4
1' -6
2'-9 1/2"4'-0"
6'-9 1/2"
9'-5"
23.06
26.11 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL…
This is the start of the file's text. The full file is on GovTribe.