11 - 596-22-700 Drawings 07_Electrical.pdf
PDF 12 MB Posted
- Solicitation number
- 36C77625B0040
About this file
This document is an electrical symbols and legend drawing (Sheet E-001) from a set of bid documents for the EHRM Infrastructure Upgrades project at the Lexington VA Health Care System. The drawing provides comprehensive electrical schematic symbols and notations used throughout the project's electrical design, including detailed legends for lighting fixtures, power equipment, wiring devices, circuiting symbols, and electrical plan notation standards. The drawing includes mounting height standards for various electrical components like receptacles, switches, and panels, ranging from 18" to 84" above finished floor, and lists extensive abbreviations and technical terminology used in electrical engineering documentation. The symbols are part of a fully sprinklered bid document set for electrical infrastructure upgrades, prepared by Spur Design LLC for the Veterans Health Administration, with the project number 596-22-700 located in Leestown, Kentucky.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UE
OE
M/G 400A/3P
M/G 400A/3P
C
PC
R
TS
T
100/3
100/3/70
100/3/70/1
100/3/CB
PP
J
GF
OR
OR
OR
EPO
AM
VM
DM
ST
KK
GFR
M
SPD
R
LP1
1,3,5
A1
LIGHT FIXTURE, CEILING MOUNTED
A1 = LIGHT FIXTURE TYPE "A1E" REFER TO LIGHT
FIXTURE SCHEDULE
a = SWITCHED BY SWITCH "a"
NL = NIGHT LIGHT
= ARROW INDICATES AIMING DIRECTION
a
LIGHTING TRACK WITH TRACK LIGHT FIXTURES
A1E = LIGHT FIXTURE TYPE "A1E" REFER TO LIGHT
FIXTURE SCHEDULE
a = SWITCHED BY SWITCH "a"
LIGHT FIXTURE, POLE MOUNTED
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
LIGHT FIXTURE, WALL MOUNTED
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
EMERGENCY BATTERY PACK LIGHT FIXTURE,
WALL MOUNTED
Y1E = LIGHT FIXTURE TYPE "Y1E" REFER TO LIGHT
FIXTURE SCHEDULe
EMERGENCY BATTERY PACK LIGHT FIXTURE,
CEILING MOUNTED
Y1E = LIGHT FIXTURE TYPE "Y1E" REFER TO LIGHT
FIXTURE SCHEDULE
EXIT SIGN, WALL MOUNTED, FACE/ARROWS AS INDICATED
X1E = LIGHT FIXTURE TYPE "X1E" REFER TO LIGHT
FIXTURE SCHEDULE
EXIT SIGN, CEILING MOUNTED, FACE/ARROWS AS INDICATED
X1E = LIGHT FIXTURE TYPE "X1E" REFER TO LIGHT
FIXTURE SCHEDULE
EMERGENCY LIGHT FIXTURE, CEILING MOUNTED
A1E = LIGHT FIXTURE TYPE "A1E" REFER TO LIGHT
FIXTURE SCHEDULE
a = SWITCHED BY SWITCH "a"
NL = NIGHT LIGHT
A1E a
A1 a
A1
A1
X1E
X1E
Y1E
Y1E
HOMERUN TO PANELBOARD
TICK MARKS INDICATE NUMBER OF CONDUCTORS.
DESIGNATIONS ARE PANELBOARD AND
CIRCUIT NUMBERS.
UNSWITCHED HOT CONDUCTORS SHOWN LEADING
NEUTRAL CONDUCTOR
NEUTRAL CONDUCTOR
SWITCHED HOT CONDUCTORS SHOWN TRAILING
GROUND CONDUCTOR
EQUIPMENT GROUNDING CONDUCTOR IN RACEWAY
ISOLATED GROUNDING CONDUCTOR IN RACEWAY
CONCEALED RACEWAY
EXPOSED RACEWAY
RACEWAY TURNING DOWN
RACEWAY TURNING UP
EQUIPMENT TERMINATION
LOW VOLTAGE CABLE (NOT ROUTED IN CONDUIT)
LIGHT FIXTURE, BOLLARD
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
A1
RECEPTACLE, SIMPLEX, NEMA 5-20R, UNO
RECEPTACLE, DUPLEX, NEMA 5-20R, UNO
RECEPTACLE, DOUBLE-DUPLEX, NEMA 5-20R, UNO
RECEPTACLE, DUPLEX, CEILING MOUNTED, NEMA 5-20R, UNO
RECEPTACLE, SPECIAL PURPOSE
RECEPTACLE, TWIST-LOCK
RECEPTACLE, DUPLEX, FLOOR MOUNTED, NEMA 5-20R, UNO
RECEPTACLE, DUPLEX, DROP CORD, NEMA 5-20R, UNO
RECEPTACLE, MOUNTED 6" ABOVE COUNTER,
TYPE AS INDICATED ABOVE
RECEPTACLE DESIGNATIONS AS FOLLOWS:
C = CLOCK HANGER
E = EMERGENCY POWER
GF = GROUND FAULT CIRCUIT INTERRUPTER
IG = ISOLATED GROUND
S = SWITCHED
TR = TAMPER RESITANT
WP = WEATHER PROOF COVER
WR = WEATHER RESISTANT
XP = EXPLOSION PROOF
SWITCH, SINGLE POLE
SWITCH DESIGNATIONS AS FOLLOWS:
2 = TWO-POLE WALL SWITCH
3 = THREE-WAY WALL SWITCH
4 = FOUR-WAY WALL SWITCH
D = DIMMER SWITCH
OS# = OCCUPANCY SENSOR WALL SWITCH, REFER
TO OCCUPANCY SENSOR AND SWITCH SCHEDULE
P = SINGLE-POLE, SINGLE-THROW PILOT LIGHT
WALL SWITCH
K = KEYED WALL SWITCH
M = MOTOR RATED SWITCH
WP = WEATHER PROOF SWITCH AND COVER
OCCUPANCY SENSOR, CEILING MOUNTED
OS# = CEILING MOUNTED OCCUPANCY SENSOR, REFER
TO OCCUPANCY SENSOR AND SWITCH SCHEDULE
POWER PACK FOR LIGHTING CONTROL
JUNCTION BOX
RECEPTACLE ON EMERGENCY POWER
RECEPTACLE, ISOLATED GROUND TYPE
MULTI-OUTLET, SURFACE RACEWAY, 24" ON CENTER,
NEMA 5-20R, UNO
SWITCHBOARD, MOTOR CONTROL CENTER OR DISTRIBUTION
PANELBOARD ON HOUSEKEEPING PAD
PANELBOARD, RECESS MOUNTED
PANELBOARD, SURFACE MOUNTED
TRANSFORMER
DISCONNECT SWITCH, NON-FUSED, 100/3 INDICATES
AMPERES/POLES, CB = CIRCUIT BREAKER TYPE
DISCONNECT SWITCH, FUSED, 100/3/70 INDICATES
AMPERES/POLES/FUSE, CB = CIRCUIT BREAKER TYPE
COMBINATION DISCONNECT SWITCH WITH MOTOR STARTER
100/3/70/1 INDICATES AMPERES/POLES/FUSE/ NEMA STARTER
SIZE, NF = NON-FUSED, CB = CIRCUIT BREAKER TYPE
MAGNETIC MOTOR STARTER, NEMA SIZE AS NOTED,
3-POLE, UNO
CONTACTOR
PHOTOCELL
RELAY
TIME SWITCH
LOW-VOLTAGE TRANSFORMER
PUSH BUTTON, TYPE AS NOTED
VARIABLE FREQUENCY DRIVE WITH DISCONNECT SWITCH
100/3/70 INDICATES AMPERES/POLES/FUSE SIZE,
NF = NON-FUSED, CB = CIRCUIT BREAKER TYPE
UNDERGROUND ELECTRIC LINE
MULTI-SERVICE FLOOR BOX/POKE-THRU WITH POWER/DATA,
TYPE AS NOTED AND/OR SCHEDULED
CABINET, RECESS MOUNTED
CABINET, SURFACE MOUNTED
RECEPTACLE, DUPLEX, GROUND-FAULT CIRCUIT
INTERRUPTER, NEMA 5-20R, UNO
MULTI-SERVICE POWER POLE WITH POWER/DATA,
TYPE AS NOTED AND/OR SCHEDULED
OVERHEAD ELECTRIC LINE
MUSHROOM TYPE PUSH BUTTON, TYPE AS NOTED
TRANSFER SWITCH, RATINGS AS INDICATED
ATS = AUTOMATIC TRANSFER SWITCH
MTS = MANUAL TRANSFER SWITCH
TX#
600AF
500AT
3P
400AS
3P
225AF
LPS-R
275KW STANDBY
480Y/277V, 3PH, 4W
GENERATOR, SEPARATELY DERIVED
SOURCE, TYPE AND RATINGS AS INDICATED
275KW STANDBY
480Y/277V, 3PH, 4W
GENERATOR, NON-SEPARATELY DERIVED
SOURCE, TYPE AND RATINGS AS INDICATED
DRAWOUT CIRCUIT
BREAKER, RATINGS
AS INDICATED
600AF
500AT
3P
CIRCUIT BREAKER,
RATINGS AS
INDICATED
FUSED DISCONNECT
SWITCH, RATINGS
AS INDICATED
400AS
3P
225AF
LPS-R
NEMA 1
COMBINATION FUSED
SWITCH AND STARTER,
RATINGS AS
INDICATED
PANELBOARD,
SINGLE-SECTION,
RATINGS PER
SCHEDULES
PANELBOARD,
MULTI-SECTION,
RATINGS PER
SCHEDULES
AMMETER
VOLTMETER
COMBINATION DIGITAL
AMMETER/VOLTMETER
SHUNT-TRIP RELAY
KIRK-KEY INTERLOCK
GROUND-FAULT RELAY
UTILITY METER
RELAY
SURGE PROTECTION
DEVICE
AUTOMATIC TRANSFER SWITCH WITH BYPASS
TYPE AND RATINGS AS INDICATED
VARIABLE FREQUENCY
DRIVE WITH
DISCONNECT, RATINGS
AS INDICATED
GROUND CONNECTION
POTENTIAL TRANSFORMER
CURRENT TRANSFORMER
GROUND CONNECTION
WITH TEST WELL
CONTACT, OPEN
CONTACT, CLOSED
MOTOR
FEEDER TAGCAPACITOR
SURGE ARRESTER
HEATER
225A 3P
NEMA 1
COMBINATION CIRCUIT
BREAKER AND
STARTER, RATINGS AS
INDICATED
225A 3P
200A 3P
ATS#
200A 3P
ATS#
TRANSFORMER
TX#
TRANSFORMER,
SHIELDED
200A DEAD-FRONT ELBOW
600A DEAD-FRONT ELBOW
DEAD-FRONT SPLITTER
FAULT INDICATOR
LIGHTNING PROTECTION AIR TERMINAL
LIGHTNING PROTECTION CABLE CONNECTION
LIGHTNING PROTECTION GROUND ROD
LIGHTNING PROTECTION CONDUCTOR
LIGHTNING PROTECTION SYMBOLS
ELECTRICAL ONE-LINE DIAGRAM SYMBOLS
LIGHTING SYMBOLS
POWER EQUIPMENT SYMBOLS
WIRING DEVICE SYMBOLS
CIRCUITING SYMBOLS
ES EMERGENCY SHUNT RELAY
MECHANICAL OR FIRE SPRINKLER PLAN NOTE CALL OUT
PLUMBING PLAN NOTE CALL OUT
ELECTRICAL, TECHNOLOGY, OR FIRE ALARM
PLAN NOTE CALL OUT
PLUMBING EQUIPMENT DESIGNATION
EQUIPMENT DESIGNATION TAG
OWNER FURNISHED, CONTRACTOR INSTALLED
EQUIPMENT DESIGNATION
NEW WORK TO EXISTING WORK CONNECTION POINT
DETAIL REFERENCE
SECTION CUT DESIGNATION
ELECTRICAL: (AFF, AFG UNLESS NOTED OTHERWISE)
EP-101
EP-101
AUDIBLE APPLIANCES (CENTERLINE)
ALARMS (TOP)
ANNUNCIATOR PANELS (TOP)
CLOCK OUTLETS (CENTERLINE)
CONTROLS (TOP)
EXIT SIGNS (WALL-MOUNTED, BOTTOM)
FIRE ALARM ANNUNCIATOR PANEL (DISPLAY)
FIRE ALARM BELL (EXTERIOR)
FIRE ALARM CONTROL PANEL/UNIT (DISPLAY)
GROUND BAR
INTERCOM (AFEA ONLY)
INTERCOMS (TOP)
PANELS & PANELBOARDS (TOP)
PULL STATIONS (TOP)
PHOTOCELLS
RECEPTACLES (BOTTOM)
RECEPTACLES, EXTERIOR (BOTTOM)
RECEPTACLES, GARAGES (BOTTOM)
RECEPTACLES IN EQUIPMENT ROOMS (TOP)
RECEPTACLES ABOVE COUNTERTOPS (TOP)
REMOTE INDICATING LIGHT, EQUIPMENT ROOMS (TOP)
REMOTE INDICATING LIGHT, FINISHED AREAS (TOP)
SAFETY SWITCHES & STARTERS
SWITCHES (TOP)
TELEPHONE/DATA/TV OUTLETS (BOTTOM)
VISIBLE APPLIANCES (CENTERLINE)
ANNOTATION STANDARD MOUNTING HEIGHTS
ABBREVIATIONS
1P SINGLE-POLE
1PH SINGLE-PHASE
3P THREE-POLE
3PH THREE-PHASE
3W THREE-WIRE
4W FOUR-WIRE
A OR AMP AMPERE
A/C AIR CONDITIONING
A/E ARCHITECT/ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED
CABLE
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
ADO AUTOMATIC DOOR OPENER
AF AMPERE FRAME OR AMP FUSE
AFC ABOVE FINISHED COUNTER, OR
AUTOMATIC FREQUENCY CONTROL,
OR AVAILABLE FAULT CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AH AMPERE HOUR
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
AIP ABANDONED IN PLACE
ALT ALTERNATE
AMB AMBIENT
ARCH ARCHITECT
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BAT BATTERY
BC BARE COPPER
BD BOARD
BFF BELOW FINISH FLOOR
BIL BASIC INSULATION LEVEL
BLDG BUILDING
BLK BLOCK
BPIP BOILER PLANT INSTRUMENTATION PANEL
BRKR BREAKER
BYP BY-PASS
C CONDUIT
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
CD CONSTRUCTION DOCUMENTS OR
CANDELA
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED /
CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED /
OWNER INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
CLF CURRENT LIMITING FUSE
CLG CEILING
CMU CONCRETE MASONRY UNIT
COAX COAXIAL CABLE
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUED
CONTR CONTRACTOR
COORD COORDINATE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
DB DECIBEL OR DIRECT BURIAL
DC DIRECT CURRENT
DCP DIMMER CONTROL PANEL
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DISC DISCONNECT
DISTR DISTRIBUTION
DN DOWN
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DRSW DOOR SWITCH
DS DISCONNECT SWITCH
DWG DRAWING
EC EMPTY CONDUIT
EG EQUIPMENT GROUND
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMCP EMER. MONITORING CONTROL PANEL
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
ESMT EASEMENT
ETD EXISTING TO BE DEMOLISHED
ETR EXISTING TO REMAIN
ETL EXISTING TO BE RELOCATED
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXIST EXISTING
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FABL FIRE ALARM BELL
FABX FIRE ALARM BOX
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FI FILM ILLUMINATOR
FIXT FIXTURE
FLA FULL LOAD AMPS
FLEX FLEXIBLE METALLIC CONDUIT
FLUOR FLUORESCENT
FO FIBER-OPTIC
FP FIRE PROTECTION
FT FEET OR FOOT
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
G GROUND OR GENERATOR
GND GROUND
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GTB GROUND TERMINAL BOX
HCM HORIZONTAL CABLE MANAGER
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HZ HERTZ
IC INSULATION CONTACT
IESNA ILLUMINATION ENGINEERING SOCIETY
OF NORTH AMERICA
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
IWH INSTANTANEOUS WATER HEATER
JB OR J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAH KILOVOLT-AMPERE-HOUR
KVAR KILOVOLT-AMPERE-REACTIVE
KW KILOWATT
KWH KILOWATT-HOUR
KWHM KILOWATT-HOUR METER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LM LUMEN
LP LIGHT POLE
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LT LIGHT
LTCP LOCAL TEMPERATURE CONTROL PANEL
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MG MOTOR GENERATOR
MH MANHOLE
MIN MINIMUM
MLO MAIN LUGS ONLY
MOCP MAXIMUM OVERCURRENT PROTECTION
MT MOUNT
MTD MOUNTED
MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
MVA MEGAVOLT-AMPERE
MW MEGAWATT
N NEUTRAL
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NC NORMALLY CLOSED
NO NORMALLY OPEN
NS NO SCALE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OL OVERLOAD
P POLE
PA PUBLIC ADDRESS
PB PANELBOARD, OR PULL BOX, OR
PUSHBUTTON
PBB PRIMARY BONDING BUSBAR
PBPU PREFABRICATED BEDSIDE PATIENT UNIT
PCB POLYCHLORINATED BIPHENYL
PEC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
PNLBD PANELBOARD
POD POWER OPERATED DAMPER
POE POWER OVER ETHERNET
PP PATCH PANEL
PT POTENTIAL TRANSFORMER
PTRV POWER TYPE ROOF VENTILATION
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
REC RECESSED
RELO RELOCATED
REQD REQUIRED
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
RU RACK UNIT
SBB SECONDARY BONDING BUSBAR
SCC SHORT CIRCUIT CAPACITY
SD SMOKE DETECTOR
SES SERVICE ENTRANCE SECTION
SF SQUARE FEET (FOOT)
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SPEC SPECIFICATION
SPST SINGLE POLE, SINGLE THROW
SURF SURFACE
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TC TIME CLOCK
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V VOLT
VA VOLT-AMPERE
VAR VOLT-AMPERE-REACTIVE
VCM VERTICAL CABLE MANAGER
VFD VARIABLE FREQUENCY DRIVE
W WATT
WH WATER HEATER
WP WEATHERPROOF
XFER TRANSFER
XFMR TRANSFORMER
XP EXPLOSION PROOF
84" 48" 48" 84" 48" 80" 60"
120" 60" 72" 36" 48" 72" 48"
144" 18" 24" 26" 48" 44" 48"
CEILING
48" 48" 18" 84"
A
# E (CONTINUED) M (CONTINUED)
B
C
D
E
F
N
G
H
I
J
K
L
M
O
P
R
S
T
U
V
W
X
A. ELECTRICAL PLANS AND SECTIONS ARE INTENDED TO
ACCURATELY ILLUSTRATE THE SCOPE OF WORK, BUT ARE STILL
DIAGRAMMATIC IN NATURE.
B. ELECTRICAL DRAWINGS DO NOT SHOW ALL ACCESSORIES TO BE
INSTALLED. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING
THAT ALL SYSTEMS ARE FULLY FUNCTIONAL AND COMPLIANT
WITH APPLICABLE CODES.
C. ELECTRICAL DRAWINGS REFLECT COORDINATION EFFORTS
WITH BUILDING DISCIPLINES. HOWEVER, COORDINATION WITH
OTHER TRADES IS REQUIRED.
D. REFERENCE ARCHITECTURAL DRAWINGS FOR ADDITIONAL
INFORMATION REGARDING SCHEDULE AND PHASING
REQUIREMENTS. SCHEDULE WORK TO MINIMIZE DISRUPTION OF
SERVICES.
E. COORDINATE WITH SCHEDULE WITH THE CONTRACTING
OFFICER'S REPRESENTATIVE BEFORE THE START OF WORK.
F. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT REQUIRE
SHUTDOWN. COORDINATE SERVICE SHUTDOWN FOR ALL
EQUIPMENT WITH THE CONTRACTING OFFICER'S
REPRESENTATIVE.
G. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND
TYPES OF EMERGENCY AND NORMAL BRANCH WIRING DEVICES
SHALL HAVE DIVIDERS BETWEEN DEVICES.
H. UPDATE ALL PANELBOARD SCHEDULES AFFECTED AT THE
COMPLETION OF THE PROJECT.
I. IF FIELD CONDITIONS VARY FROM THE DRAWINGS, THE
CONTRACTOR SHALL DOCUMENT THE VARIATION AND REPORT
IT TO THE GENERAL CONTRACTOR FOR RESOLUTION WITH THE
ENGINEER OF RECORD.
J. CONTRACTOR SHALL METER PANELBOARDS INDICATED IN THE
DRAWING SET FOR A MINIMUM OF 30 DAYS IN ACCORDANCE
WITH ARTICLE 220.87 OF THE 2023 NATIONAL ELECTRICAL CODE.
THE MAXIMUM METERED DEMAND PLUS 125 PERCENT SHALL
NOT EXCEED THE PANELBOARD RATING. IF CALCULATED LOAD
EXCEEDS THE PANELBOARD RATING, CONTRACTOR SHALL
NOTIFY THE ENGINEER OF RECORD.
GENERAL NOTES
PROJECT CODES AND STANDARDS
A. ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS 2015
B. VA PG-18-13 VA BARRIER FREE DESIGN STANDARD 2018
(SUPPLEMENT TO ABA STANDARDS)
C. ASHRAE STANDARD 90.1-2019 – ENERGY STANDARD FOR
BUILDINGS EXCEPT LOW RISE RESIDENTIAL BUILDINGS
D. IBC 2021 – INTERNATIONAL BUILDING CODE
E. IEBC 2021 – INTERNATIONAL EXISTING BUILDING CODE
F. IECC 2021 – INTERNATIONAL ENERGY CONSERVATION CODE
G. JCAHO EC 7.40 – EMERGENCY ELECTRICAL POWER SYSTEM
INSPECTION, MAINTENANCE, AND TESTING
H. NFPA 70-2023 - NATIONAL ELECTRICAL CODE (NEC)
I. NFPA 99-2021 – HEALTH CARE FACILITIES CODE
J. NFPA 101-2021 – LIFE SAFETY CODE
K. NFPA 110-2022 – STANDARD FOR EMERGENCY AND STANDBY
POWER SYSTEMS
L. NFPA 111-2022 – STANDARDS FOR STORED ENERGY POWER
SYSTEMS
M. VA PG-18-10 ELECTRICAL DESIGN MANUAL, DECEMBER 2019
N. VA PG-18-12 OFFICE OF INFORTMATION AND TECHNOLOGY
DESIGN GUIDE (FEBRUARY 2011)
O. VA H-18-8 SEISMIC DESIGN REQUIREMENTS
P. VA PHYSICAL SECURITY & RESILIENCY DESIGN MANUAL 2020
(1 SEP 21 REVISION)
Q. INFRASTRUCTURE STANDARD FOR TELECOMMUNICATION
SPACES V3.1
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:5
ELECTRICAL SYMBOLS AND LEGEND
IEC Drawing # 134 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-001
SPUR #: 2207.00
No. REVISION DESCRIPTION DATE
28 29
LEESTOWN ROAD
CONTRACTOR
STAGING AREA
LOT A
LOT H
MAIN ENTRANCE
LOT G
LOT B
LOT C
LOT D
LOT D
LOT E
LOT F
LOT F
LOT I
LOT I
206E-414
E-414 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:5
SITE PLAN
IEC Drawing # 135 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-002
SPUR #: 2207.00
N
1" = 100'-0"
SITE PLAN1
ENGG
EQUIP
RM
STAIR
MED
RESEARCH
RM
PIPE
SPACE
CORRIDOR
SPRINKLER
PIPECORRIDOR
PODIATRY
STOR
WOMENS
TOILET
SOCIAL
WORKER
OFFICE
FIRE
CABINET
MED FOSTER
CARE OFFICE
P TOILET
CODING
COMPLIANCE
MGR
OFFICE
ELEVATOR
ELEVATOR
LOBBYPODIATRY
EXAM
ELEVATOR
STAIR
PODIATRY
SECTION
CHIEF
TOILET
PODIATRY
EXAM
SPD
CLOSET
MENS
TOILET
PIPE
SPACE
STAIR
FOYER
PODIATRIST
OFFICE
CODING
OFFICE
BREAK
RM
EXAMINATION
SOCIAL
WORKER
OFFICE
SOCIAL
WORK
SUPV
OFFICE
OFFICE
OFFICECOMPLIANCE
ANALYST
WAITING
RM
RECEPTIONIST
TEL/DATA
CLOSET IT
CLOSET
PODIATRY
RM
PODIATRY
RM
PODIATRY
RM
PODIATRY
RM
PODIATRY
RM
PODIATRY
CONFERENCE
RM
CODING
E-401
EXISTING
PHONE ROOM
E-401
E-401
TR
31A
E-401
E-401
E-401
5TR
147A-1 E-401
E-401
E-401
TR
229-1 E-401
E-401
E-401
E-402
1TR
331-1 E-402
E-402
E-402
E-402
TR
419-1 E-402
E-402
E-402
KEY PLAN
LEESTOWN ROAD
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
GENERAL OVERALL PLAN NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:0
BUILDING 1 - REFERENCE PLANS
IEC Drawing # 136 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-101
SPUR #: 2207.00
N
1" = 20'-0"
B1 - GROUND LEVEL1
N
1" = 20'-0"
B1 - LEVEL 12
N
1" = 20'-0"
B1 - LEVEL 23
N
1" = 20'-0"
B1 - LEVEL 34
N
1" = 20'-0"
B1 - LEVEL 45
E-403
TR
24A-3
E-403
E-403
E-403
E-402
TR
220-2
E-402
E-402
E-402
E-403
E-402
TR
122-2
TR
131A-3
E-403
E-402
E-402
E-402
E-403
E-403
DISTRIBUTION PANEL '2EM' (ETR) LOCATED IN BASEMENT.
SHOWN HERE FOR LOCATION REFERENCE. REFER TO
ONE-LINE DIAGRAM FOR MORE INFORMATION.
E-403
E-403
TR
222A-3
E-403
E-403
KEY PLAN
LEESTOWN ROAD
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
GENERAL OVERALL PLAN NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:0
BUILDING 2, 3 - REFERENCE PLANS
IEC Drawing # 137 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-102
2, 3
SPUR #: 2207.00
N
1" = 20'-0"
B2, B3 - GROUND LEVEL1
N
1" = 20'-0"
B2 - LEVEL 22
N
1" = 20'-0"
B2, B3 - LEVEL 13
N
1" = 20'-0"
B3 - LEVEL 24
E-404
E-404
TR
102-4
E-404
E-404
DISTRIBUTION PANEL 'EMCC4' (ETR) SHOWN HERE
FOR LOCATION REFERENCE. REFER TO ONE-LINE
DIAGRAM FOR MORE INFORMATION.
E-404
E-404
WAREHOUSE
AREA
ELEC.
6C-12
PANELBOARD '12LP1' (ETR) SHOWN HERE FOR
LOCATION REFERENCE. REFER TO PANELBOARD
SCHEDULES FOR MORE INFORMATION.
KEY PLAN
LEESTOWN ROAD
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
GENERAL OVERALL PLAN NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:0
BUILDING 4, 12 - REFERENCE PLANS
IEC Drawing # 138 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-103
4, 12
SPUR #: 2207.00
N
1" = 20'-0"
B4 - LEVEL 11
N
1" = 20'-0"
B12 - LEVEL 12
E-404
CLOSET
6B-16
E-404
TR
15-16
E-405
E-405
E-405
E-405
E-404
DISTRIBUTION PANEL '16EM' (ETR) SHOWN HERE
FOR LOCATION REFERENCE. REFER TO ONE-LINE
DIAGRAM FOR MORE INFORMATION.
ELEC
7-16
E-405
CLOSET
115B-16
E-405
TR
102-16
E-405
E-405
E-405
E-405
E-405
CLOSET
222A-16
E-405
E-406
E-406
E-406
E-406
TR
207A-16
E-406
E-406
TR
13C-17
E-406
E-406
E-407
E-407
E-407
E-407
NEW MCR
22-17
ELEC
14-17
PNL 'EM17' (NEW)
'17ATS/EM' (NEW)
PNL 'MP-17' (NEW)
E-408
CLOSET
126-17
E-408
E-408
E-408
E-408
CLOSET
218-17
E-408
E-408
E-408
KEY PLAN
LEESTOWN ROAD
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
GENERAL OVERALL PLAN NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:1
BUILDING 16, 17 - REFERENCE PLANS
IEC Drawing # 139 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-104
SPUR #: 2207.00
N
1" = 20'-0"
B16 - GROUND LEVEL1
N
1" = 20'-0"
B16 - LEVEL 12
N
1" = 20'-0"
B16 - LEVEL 23
N
1" = 20'-0"
B17 - GROUND LEVEL4
N
1" = 20'-0"
B17 - LEVEL 15
N
1" = 20'-0"
B17 - LEVEL 26
E-409
TR
19-25
E-409
DISTRIBUTION PANEL '25EM' (ETR) SHOWN HERE
FOR LOCATION REFERENCE. REFER TO ONE-LINE
DIAGRAM FOR MORE INFORMATION.
E-409
TR
112-25
E-409
E-409
TR
214-25
E-409
KEY PLAN
LEESTOWN ROAD
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
GENERAL OVERALL PLAN NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:1
BUILDING 25 - REFERENCE PLANS
IEC Drawing # 140 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-105
SPUR #: 2207.00
N
1" = 20'-0"
B25 - GROUND LEVEL1
N
1" = 20'-0"
B25 - LEVEL 12
N
1" = 20'-0"
B25 - LEVEL 23
E-410
E-409
TR
2F-27
TR
16D-27
E-410
E-410
TR
136A-27
TR
117A-27
E-411
E-410
TR
236A-27
TR
217A-27
E-411
E-411
TR
1A-28
E-411
TR
156-28
E-411
DISTRIBUTION PANEL '28EM' (ETR) SHOWN HERE
FOR LOCATION REFERENCE. REFER TO ONE-LINE
DIAGRAM FOR MORE INFORMATION.
ELEC
185-28
E-411
TR
247-28
E-411
KEY PLAN
LEESTOWN ROAD
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
GENERAL OVERALL PLAN NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:3 :4
A
M
BUILDING 27, 28 - REFERENCE PLANS
IEC Drawing # 141 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-106
SPUR #: 2207.00
N
1" = 20'-0"
B27 - GROUND LEVEL1
N
1" = 20'-0"
B27 - LEVEL 12
N
1" = 20'-0"
B27 - LEVEL 23
N
1" = 20'-0"
B28 - GROUND LEVEL4
N
1" = 20'-0"
B28 - LEVEL 15
N
1" = 20'-0"
B28 - LEVEL 26
E-412
E-412
CLOSET
21-29
E-412
E-412
DISTRIBUTION PANEL '29EM' (ETR) SHOWN HERE
FOR LOCATION REFERENCE. REFER TO ONE-LINE
DIAGRAM FOR MORE INFORMATION.
HOUSEKEEPING
STORAGE
19-29
TR
19B-29
E-412
CLOSET
134A-29
E-412
E-412
E-412
TR
135A-29
PROGRAM
MANAGER
OFFICE
135-29
E-413
TR
239A-29
E-413
SHOP
2-47
E-413
PANELBOARD '47EM1' (ETR) SHOWN HERE FOR
LOCATION REFERENCE. REFER TO PANELBOARD
SCHEDULES FOR MORE INFORMATION.
SHOP
1-47
E-413
E-413
SERVICE
2-48
PANELBOARD '48LP1' (ETR) SHOWN HERE FOR
LOCATION REFERENCE. REFER TO PANELBOARD
SCHEDULES FOR MORE INFORMATION.
ELEC
004A-48
KEY PLAN
28 29
LEESTOWN ROAD
E-413
WORK SHOP
8-37
E-413
PANELBOARD '37EM1' (ETR) SHOWN HERE FOR
LOCATION REFERENCE. REFER TO PANELBOARD
SCHEDULES FOR MORE INFORMATION.
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
3 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
EXISTING WALL TO REMAIN
NEW NON-RATED WALLS
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON
EACH FLOOR WITHIN EACH BUILDING.
2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW
CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.
GENERAL OVERALL PLAN NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
/1
/2
:3 :4
A
M
BUILDING 29, 37, 47, 48 - REFERENCE
PLANS
IEC Drawing # 142 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-107
SPUR #: 2207.00
N
1" = 20'-0"
B29 - GROUND LEVEL1
N
1" = 20'-0"
B29 - LEVEL 12
N
1" = 20'-0"
B29 - LEVEL 23
N
1" = 20'-0"
B47 - LEVEL 16
N
1" = 20'-0"
B48 - LEVEL 17
N
1" = 20'-0"
B37 - LEVEL 14
EXISTING
PHONE ROOM
TR
31A
(ETD)
TR
147A-1
2,M
PNL '1EM1-IT'
(NEW)
1-DS-147A
'SBB-B1-147A' 17 1EM1-IT
1,3,5
1EM1-IT
2,4,6
1EM1-IT
1EMG-IT
19,21
1EM1-IT
1EM1-IT
21 2220
(TYP)
TR
147A-1
(ETD)
(ETD)
(ETD)
TR
147A-1
(ETD)
TR
147A-1
PNL '1EM1-IT'
(NEW)
C2
C2
1EM1-IT
EXISTING
PHONE ROOM
EXISTING
PHONE ROOM
TR
31A
PNL '1EMG-IT'
(NEW)
1EMG-IT
C1
C1
TR
229-1
(ETD)
1TR
229-1 PNL '1EM2-IT'
(NEW)
1-DS-229
'SBB-B1-229'17
2,M
1EM2-IT
71EMG-IT
11,13 1EM2-IT
1EM2-IT
1EM2-IT
1,3,5
1EM2-IT
2,4,6
2021 22
(TYP)
(ETD)
TR
229-1
PNL '1EM2-IT'
(NEW)
C1
C2
TR
229-1
1EM2-IT
1- C
U -0
A
1- C
U -1
1- C
U -2
1- C
U -3
1- C
U -4
EXISTING
PHONE ROOM
TR
31A
2021 22
1-DS-031A
2,M*
PNL '1EMG-IT'
(NEW)
1EMG-IT
2,4,6
1EMG-IT
1,3,5
1EMG-IT
1EMG-IT
1EMG-IT
'SBB-B1-31A'
30/2/30/3R
MOUNTED ON UNISTRUT
(TYP OF 5)
1EMG-IT
19,21
1EMG-IT
11,13
1EMG-IT
15,17
1EMG-IT
16,18
(TYP)
1EMG-IT
12,14 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:2
BUILDING 1 - ENLARGED PLANS
IEC Drawing # 143 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-401
SPUR #: 2207.00
1/4" = 1'-0"
B1 - GROUND LEVEL - 31 - POWER DEMO PLAN1
1/4" = 1'-0"
B1 - LEVEL 1 - 147A - POWER PLAN6 1/4" = 1'-0"
B1 - LEVEL 1 - 147A - POWER DEMO PLAN5
1/4" = 1'-0"
B1 - LEVEL 1 - 147A - LIGHTING DEMO PLAN71/4" = 1'-0"
B1 - LEVEL 1 - 147A - LIGHTING PLAN8
1/4" = 1'-0"
B1- GROUND LEVEL - 31 - LIGHTING DEMO PLAN31/4" = 1'-0"
B1 - GROUND LEVEL - 31A - LIGHTING PLAN4
1/4" = 1'-0"
B1 - LEVEL 2 - 229 - POWER DEMO PLAN91/4" = 1'-0"
B1 - LEVEL 2 - 229 - POWER PLAN10
1/4" = 1'-0"
B1 - LEVEL 2 - 229 LIGHTING DEMO PLAN111/4" = 1'-0"
B1 - LEVEL 2 - 229 - LIGHTING PLAN12
1/4" = 1'-0"
B1 - GROUND LEVEL - 31A - POWER PLAN2
No. REVISION DESCRIPTION DATE
GENERAL DEMOLITION NOTES:
A. ALL RECEPTACLES, UPS SYSTEMS, AND PDUS TO BE DEMOLISHED IN AREA OF
WORK. REMOVE CONDUIT AND CONDUCTORS BACK TO UPSTREAM PANEL
BOARD.
ELECTRICAL KEYNOTES
1 ALL RECEPTACLES TO BE DEMOLISHED IN AREA OF WORK, UNLESS NOTED
OTHERWISE. REMOVE CONDUIT AND CONDUCTORS BACK TO UPSTREAM
PANELBOARD.
2 REMOVE ALL LIGHTING AND ASSOCIATED LIGHTING CONTROLS IN SPACE.
DEMOLISH EXISTING LIGHTING POWER CIRCUIT BACK TO NEAREST JUNCTION BOX
AND LABEL FOR REUSE. MAINTAIN CIRCUIT CONTINUITY TO EXISTING TO REMAIN
LIGHT FIXTURES NOT IN SCOPE.
6 REMOVE ALL LIGHTING AND ASSOCIATED LIGHTING CONTROLS IN SPACE.
DEMOLISH EXISTING LIGHTING POWER CIRCUIT BACK TO PANELBOARD, OR
JUNCTION BOX AS REQUIRED TO MAINTAIN CONTINUITY OF CONNECTED LIGHTING
AREAS THAT ARE NOT WITHIN THE AREA OF WORK.
11 PROVIDE NEW 208Y/120V, 3-PHASE, 30A RECEPTACLE (NEMA L21-30R). MOUNT
RECEPTACLE OVERHEAD TO SERVE POWER TO RACK-MOUNTED UPS AND ZONE
PDU. REFER TO DETAIL 2 ON SHEET E-501 FOR PDU ARRANGEMENT IN
TELECOMMUNICATION RACK.
17 REFER TO 'TELECOM GROUNDING RISER DIAGRAM' ON SHEET E-503 FOR TE
GROUND BAR CONNECTIONS AND BONDING.
18 INDOOR UNIT IS POWERED BY OUTDOOR UNIT. REFER TO MECHANICAL DRAWINGS
FOR EXACT LOCATIONS OF OUTDOOR UNIT AND MORE INFORMATION. PROVIDE 30A,
2-POLE, 30A-FUSED DISCONNECT SWITCH ON UNISTRUT FOR OUTDOOR UNIT.
COORDINATE WORK WITH MECHANICAL CONTRACTOR.
20 PROVIDE NEW 5KW RACK-MOUNTED UPS. BASIS OF DESIGN IS EATON BLADEUPS
[SKU# ZC0517700110000]. UPS SHALL SUPPLY A MINIMUM OF 10 MINUTES RUN TIME
OF ITS CAPACITY.
21 PROVIDE (2) NEW VERTICAL RACK-MOUNTED 208Y/120V, 3-PHASE, 20A INPUT PDUS
PER RACK. BASIS OF DESIGN IS CHATSWORTH ECONNECT PDU [MODEL# L2-1N0G3].
REFER TO SHEET E-501 FOR PDU CONNECTION TO RACK-MOUNTED UPS, ZONE
PDU'S AND/OR 208Y/120V L21-20R RECEPTACLE DETAILS.
22 PROVIDE NEW 208V, 30A, 3-PHASE HORIZONTAL RACK-MOUNTED ZONE PDU. BASIS
OF DESIGN ZONIT PDU [MODEL# ZPDS-208V30A-L21-4L21-20-CR]. REFER TO DETAIL 2
ON SHEET E-501 FOR PDU ARRANGEMENT IN TELECOMMUNICATION RACK.
TR
331-1
ETR
(ETD)
TR
331-1
PNL '1EM3-IT'
(NEW)
2,M
'SBB-B1-331'
1-DS-331
1EM3-IT
1,3,5
1EM3-IT
2,4,6
1EM3-IT
1EM3-IT
1EM3-IT
71EMG-IT
15,17
20 21
TR
419-1
(ETD)
TR
419-1
PNL '1EM4-IT'
(NEW)
2,M
1-DS-419
'SBB-B1-419'
1EM4-IT
1EMG-IT
16,18
1EM4-IT
1EM4-IT
1EM4-IT
1,3,5
1EM4-IT
2,4,6
TR
331-1
(ETD)
C1
C1
PNL '1EM3-IT'
(NEW)
TR
331-1
1EM3-IT
TR
419-1
(ETD)
C1
C1
PNL '1EM4-IT'
(NEW)
TR
419-1
1EM4-IT
TR
122-2
(ETD)
TR
122-2
'2EM1-IT' (NEW)
'SBB-B2-122'
2,M
2-DS-122
2EM1-IT
1,3,5
2EM1-IT
2,4,6
2EM1-IT
2EM1-IT
2EM1-IT
20 21
(TYP)
2-CU-122
2-CU-220
2EM1-IT
15,17
2EM1-IT
11,13
(ON GROUND)
(ON GROUND)
30/2/30/3R
(ON GROUND)
(TYP OF 2)
(ETD)
TR
122-2
TR
122-2
'2EM1-IT' (NEW)
C1C1
2EM1-IT
TR
220-2
(ETD)
11TR
220-2
2,M
PNL '2EM2-IT'
(NEW)
2-DS-220
'SBB-B2-220'
2EM2-IT
2EM1-IT
11,13
2EM2-IT
2EM2-IT
2EM2-IT
1,3,5
2EM2-IT
2,4,6
(TYP)
(ETD)
TR
220-2
PNL '2EM2-IT'
(NEW)
C2
C2 TR
220-2
2EM2-IT
8th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:2
BUILDING 1, 2 - ENLARGED PLANS
IEC Drawing # 144 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-402
1, 2
SPUR #: 2207.00
1/4" = 1'-0"
B1 - LEVEL 3 - 331 - POWER DEMO PLAN11/4" = 1'-0"
B1 - LEVEL 3 - 331 - POWER PLAN2
1/4" = 1'-0"
B1 - LEVEL 4 - 419 - POWER DEMO PLAN51/4" = 1'-0"
B1 - LEVEL 4 - 419 - POWER PLAN6
1/4" = 1'-0"
B1 - LEVEL 3 - 331 - LIGHTING DEMO PLAN31/4" = 1'-0"
B1 - LEVEL 3 - 331 - LIGHTING PLAN41/4" = 1'-0"
B1 - LEVEL 4 - 419 - LIGHTING DEMO PLAN71/4" = 1'-0"
B1 - LEVEL 4 - 419 - LIGHTING PLAN8
1/4" = 1'-0"
B2 - LEVEL 1 - 122 - POWER DEMO PLAN9
1/4" = 1'-0"
B2 - LEVEL 1 - 122 - POWER PLAN10
1/4" = 1'-0"
B2 - LEVEL 1 - 122 - LIGHTING DEMO PLAN111/4" = 1'-0"
B2 - LEVEL 1 - 122 - LIGHTING PLAN12
1/4" = 1'-0"
B2 - LEVEL 2 - 220 - POWER DEMO PLAN13
1/4" = 1'-0"
B2 - LEVEL 2 - 220 - POWER PLAN14
1/4" = 1'-0"
B2 - LEVEL 2 - 220 - LIGHTING DEMO PLAN151/4" = 1'-0"
B2 - LEVEL 2 - 220 - LIGHTING PLAN16
No. REVISION DESCRIPTION DATE
GENERAL DEMOLITION NOTES:
A. ALL RECEPTACLES, UPS SYSTEMS, AND PDUS TO BE DEMOLISHED IN AREA OF
WORK. REMOVE CONDUIT AND CONDUCTORS BACK TO UPSTREAM PANEL
BOARD.
ELECTRICAL KEYNOTES
1 ALL RECEPTACLES TO BE DEMOLISHED IN AREA OF WORK, UNLESS NOTED
OTHERWISE. REMOVE CONDUIT AND CONDUCTORS BACK TO UPSTREAM
PANELBOARD.
2 REMOVE ALL LIGHTING AND ASSOCIATED LIGHTING CONTROLS IN SPACE.
DEMOLISH EXISTING LIGHTING POWER CIRCUIT BACK TO NEAREST JUNCTION BOX
AND LABEL FOR REUSE. MAINTAIN CIRCUIT CONTINUITY TO EXISTING TO REMAIN
LIGHT FIXTURES NOT IN SCOPE.
11 PROVIDE NEW 208Y/120V, 3-PHASE, 30A RECEPTACLE (NEMA L21-30R). MOUNT
RECEPTACLE OVERHEAD TO SERVE POWER TO RACK-MOUNTED UPS AND ZONE
PDU. REFER TO DETAIL 2 ON SHEET E-501 FOR PDU ARRANGEMENT IN
TELECOMMUNICATION RACK.
17 REFER TO 'TELECOM GROUNDING RISER DIAGRAM' ON SHEET E-503 FOR TE
GROUND BAR CONNECTIONS AND BONDING.
18 INDOOR UNIT IS POWERED BY OUTDOOR UNIT. REFER TO MECHANICAL DRAWINGS
FOR EXACT LOCATIONS OF OUTDOOR UNIT AND MORE INFORMATION. PROVIDE 30A,
2-POLE, 30A-FUSED DISCONNECT SWITCH ON UNISTRUT FOR OUTDOOR UNIT.
COORDINATE WORK WITH MECHANICAL CONTRACTOR.
20 PROVIDE NEW 5KW RACK-MOUNTED UPS. BASIS OF DESIGN IS EATON BLADEUPS
[SKU# ZC0517700110000]. UPS SHALL SUPPLY A MINIMUM OF 10 MINUTES RUN TIME
OF ITS CAPACITY.
21 PROVIDE (2) NEW VERTICAL RACK-MOUNTED 208Y/120V, 3-PHASE, 20A INPUT PDUS
PER RACK. BASIS OF DESIGN IS CHATSWORTH ECONNECT PDU [MODEL# L2-1N0G3].
REFER TO SHEET E-501 FOR PDU CONNECTION TO RACK-MOUNTED UPS, ZONE
PDU'S AND/OR 208Y/120V L21-20R RECEPTACLE DETAILS.
22 PROVIDE NEW 208V, 30A, 3-PHASE HORIZONTAL RACK-MOUNTED ZONE PDU. BASIS
OF DESIGN ZONIT PDU [MODEL# ZPDS-208V30A-L21-4L21-20-CR]. REFER TO DETAIL 2
131A-3
(ETD) (ETD)
(ETD)
(ETD)
(ETD)
(ETD)
TR
222A-3
(ETD)
(ETD)
(ETD)
TR
24A-3
(ETD)
(ETD)
(ETD)
(ETD)
(ETD)
(ETD)
(ETD)
(ETD)
TR
222A-3
PNL '3EM2-IT'
(NEW)
3EM2-IT
3EM2-IT
3EM2-IT
3EM2-IT
1,3,5
3EM2-IT
2,4,6
'SBB-B3-222A' 17
3-DS-222A
20 21
(TYP.)
TR
222A-3
TR
222A-3
C1
C1
3EM2-IT
PNL '3EM2-IT'
(NEW)
TR
24A-3
PNL '3EMG-IT'
(NEW)3EMG-IT
3EMG-IT
3EMG-IT
3EMG-IT
1,3,5
3EMG-IT
2,4,6
'SBB-B3-24A' 17 3-CU-024A
3-CU-131A
3-CU-222A
3-DS-024A
3EM1-IT
18,20
3EM1-IT
14,16
3EM1-IT
10,12
30/2/30/3R
(TYP OF 3)
TR
24A-3
TR
24A-3
C2
C2
3EMG-IT
PNL '3EMG-IT'
(NEW)
TR
131A-3
PNL '3EM1-IT'
(NEW)
3EM1-IT
3EM1-IT
3EM1-IT
3EM1-IT
1,3,5
3EM1-IT
2,4,6
'SBB-B3-131A' 17
3-DS-131A
(TYP.)
TR
131A-3
TR
131A-3
PNL '3EM1-IT'
(NEW)
3EM1-IT
C1
C1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH: SETH CAVIN, LICENSE #8468 EXP. 06/30/2024
ENGR: SPUR DESIGN, LLC COA #5197 EXP. 12/31/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB ENG.
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 86301
(928) 774-0992
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, #1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
RATED ENGINEERING
609 S. KELLY AVE., SUITE H2
EDMOND, OK 73003
(405) 856-2965
STRUCTURAL
STAND
8234 ROBINSON
OVERLAND PARK, KS 66204
(913) 214-2169
-M a r-
:1
:3
BUILDING 3 - ENLARGED PLANS
IEC Drawing # 145 OF 257ES
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES - LEESTOWN, KY
03/15/2024
596-22-700
LEXINGTON VA HEALTH CARE
2250 LEESTOWN RD
LEXINGTON, KY 40511
E-403
SPUR #: 2207.00
1/4" = 1'-0"
B3 - LEVEL 1 - 131A - POWER DEMO PLAN5
1/4" = 1'-0"
B3 - LEVEL 2 - 222A - POWER DEMO PLAN9
1/4" = 1'-0"
B3 - GROUND LEVEL - 24A - POWER DEMO PLAN1
1/4" = 1'-0"
B3 - LEVEL 2 - 222A - POWER PLAN10
1/4" = 1'-0"
B3 - LEVEL 2 - 222A - LIGHTING DEMO PLAN111/4" = 1'-0"
B3 - LEVEL 2 - 222A - LIGHTING PLAN12
1/4" = 1'-0"
B3 - GROUND LEVEL - 24A - POWER PLAN2
1/4" = 1'-0"
B2 - GROUND LEVEL - 24A - LIGHTING DEMO PLAN31/4" = 1'-0"
B3 - GROUND LEVEL - 24A - LIGHTING PLAN4
1/4" = 1'-0"
B3 - LEVEL 1 - 131A - POWER PLAN6
1/4" = 1'-0"
B3 - LEVEL 1 - 131A - LIGHTING DEMO PLAN71/4" = 1'-0"
B3 - LEVEL 1 - 131A - LIGHTING PLAN8
No. REVISION DESCRIPTION DATE
GENERAL…