This is a construction specification section for door hardware at Walla Walla VA Medical Center in Washington. The specification establishes technical requirements, standards, and installation procedures for all door hardware components associated with the "Repair Exterior Features Envelope Maintenance & Repair" project (VA Project No. 687-20-101), with a completion date of 01/26/2026.

The specification requires compliance with ANSI/BHMA standards for mortise locks, hinges, cylinders, thresholds, and weatherstrips. Key product requirements include three-knuckle butt hinges (five-knuckle where unavailable), mortise locksets Series 1000 Grade 2 minimum with cast stainless steel lever handles, and cylindrical locksets Series 4000 Grade I with ADA-compliant levers. All hardware must meet Architectural Barriers Act Accessibility Standards unless otherwise specified. Locks must feature removable core cylinders with at least six pins, interchangeable into a Great Grand Master Key System, and 19 mm latch bolt throw for fire-rated double doors. Thresholds must conform to ANSI A156.21 mill finish extruded aluminum with non-slip abrasive finish at exterior and moisture-exposed doors. All exposed hardware finishes must meet ANSI A156.18 standards, with finish designations 626 or 630 for most applications. Hardware must be from the same manufacturer for mortise locksets, hinges, door closers, exit devices, and floor closers. The contractor must submit six copies of a hardware schedule prepared by an AHC-certified hardware consultant and provide two final approved copies to the VAMC Locksmith. Installation requires standard hardware heights with locksets centered at 1024 mm, specific hinge requirements based on door dimensions and weight, and machine screws with lead expansion shields for fastening. Post-installation inspection includes hardware re-adjustment, maintenance procedure evaluation, and written problem identification.

View the file

Other files for this federal contract opportunity

Other files attached to 687-23-101 CON Repair Exterior Features, newest first.
File Type Posted
36C26026R0033 0009.pdf PDF
36C26026R0033 0008.docx DOCX document
Attachment 10 - RFI Questions P0008.docx DOCX document
Attachment 4 - 687-23-101_100__COMPLETE_DRAWING_SET_VA REDLI.pdf PDF
Attachment 2 - SPECS VOL 1 Rev 1 Less T1 and T2.pdf PDF
Attachment 14 - Asbestos Survey - Building 63 - Final Rev 1.pdf PDF
Attachment 18 - Asbestos Survey - Building 81 - Final Rev 1.pdf PDF
Attachment 24 - Asbestos Survey - Building T2 - Final Rev 1.pdf PDF
Attachment 28 - RFI and Responses 687-23-101.xlsx XLSX spreadsheet
36C26026R0033 0007.pdf PDF
Attachment 10 - Asbestos Survey - Building 31 - Final Rev 1.pdf PDF
Attachment 11 - Asbestos Survey - Building 41 - Final Rev 1.pdf PDF
Attachment 13 - Asbestos Survey - Building 49 - Final Rev 1.pdf PDF
Attachment 16 - Asbestos Survey - Building 66 - Final Rev 1.pdf PDF
Attachment 19 - Asbestos Survey - Building 82 - Final Rev 1.pdf PDF
Attachment 20 - Asbestos Survey - Building 105 - Final Rev 1.pdf PDF
Attachment 21 - Asbestos Survey - Building 107 - Final Rev 1.pdf PDF
Attachment 25 - Asbestos Survey - Building T7 - Final Rev 1.pdf PDF
Attachment 17 - Asbestos Survey - Building 76 - Final Rev 1.pdf PDF
Attachment 29 - Mobilization-Project-Areas.pdf PDF
Attachment 12 - Asbestos Survey - Building 48 - Final Rev 1.pdf PDF
Attachment 15 - Asbestos Survey - Building 65 - Final Rev 1.pdf PDF
Attachment 22 - Asbestos Survey - Building 120 - Final Rev 1.pdf PDF
Attachment 23 - Asbestos Survey - Building T1 - Final Rev 1.pdf PDF
Attachment 26 - Exterior Building Lead Condition-Presence-Absence.pdf PDF
36C26026R0033 0006.docx DOCX document
Site Visit 2nd Sheet.pdf PDF
Site Visit Sign-In Sheet - February 9 2026.jpg JPG image
36C26026R0033 0005.docx DOCX document
36C26026R0033 0004.docx DOCX document
687-23-101_Repair_Exterior_Features_Geotech Memorandum.pdf PDF
687-23-101- 36C26026R0033 - Contractor Questions and Answers.pdf PDF
36C26026R0033 0003.docx DOCX document
36C26026R0033 0002.docx DOCX document
36C26026R0033 0002 pdf version Rev. 01.pdf PDF
36C26026R0033 0002 pdf version Rev. 01.pdf PDF
36C26026R0033 pdf version.pdf PDF
36C26026R0033 0001.docx DOCX document
36C26026R0033.docx DOCX document
Attachment 8 - Contractor Rules of Behavior 687-23-101 Repair Exterior Features.pdf PDF
Attachment 7 - PPQ NCO 20 687-23-101.docx DOCX document
Attachment 5 - Divisional Price Breakout.xlsx XLSX spreadsheet
Attachment 9 - Wage Determination 1.23.2026.pdf PDF
Attachment 6 - Limitations on Subcontracting 687-23-101 Repair Exteriors.docx DOCX document
Attachment 1 - SOW CON Repair Exterior Features Rev 01.docx DOCX document
Attachment 4 - COMPLETE_DRAWING_SET_VA REDLINES.pdf PDF
Attachment 3 - SPECS VOL 2 687-23-101 Exterior Repairs 01.26.2026.pdf PDF
Attachment 2 - SPECS VOL 1 687-23-101 Exterior Repairs 01.26.2026.pdf PDF
Show all 48

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WWVA

WALLA WALLA, WA

100% CONSTRUCTION DOCUMENTS

01/26/2026

Repair Exterior Features Envelope Maintenance & Repair

WALLA WALLA, WA

VA PROJECT NO. 687-20-101

08 71 00 - PAGE 1 OF 8

DOOR HARDWARE

SECTION 08 71 00

DOOR HARDWARE

PART 1 - GENERAL

1.1 REFERENCE STANDARDS

A. BHMA A156.13 - Mortise Locks and Latches; 2022.

1.2 DESCRIPTION

A. Door hardware and related items necessary for complete installation and operation of doors.

1.3 RELATED WORK

A. Painting: Section 09 91 00, PAINTING.

1.4 GENERAL

A. All hardware shall comply with ABAAS, (Architectural Barriers Act

Accessibility Standard) unless specified otherwise.

B. Hardware for application on metal and wood doors and frames shall be made to standard templates. Furnish templates to the fabricator of these items in sufficient time so as not to delay the construction.

C. The following items shall be of the same manufacturer, except as otherwise specified:

1. Mortise locksets.

2. Hinges for hollow metal and wood doors.

3. Surface applied overhead door closers.

4. Exit devices.

5. Floor closers.

1.5 MAINTENANCE MANUALS

A. In accordance with Section 01 00 00, GENERAL REQUIREMENTS Article titled "INSTRUCTIONS", furnish maintenance manuals and instructions on all door hardware. Provide installation instructions with the submittal documentation.

1.6 SUBMITTALS

A. Submittals shall be in accordance with Section 01 33 23, SHOP

DRAWINGS, PRODUCT DATA, AND SAMPLES. Submit 6 copies of the schedule per Section 01 33 23. Submit 2 final copies of the final approved schedules to VAMC Locksmith as record copies (VISN Locksmith if the

VAMC does not have a locksmith).

100% CONSTRUCTION DOCUMENTS

01/26/2026

Repair Exterior Features Envelope Maintenance & Repair

WALLA WALLA, WA

VA PROJECT NO. 687-20-101

08 71 00 - PAGE 2 OF 8

DOOR HARDWARE

B. Hardware Schedule: AHC certified hardware consultant to prepare and submit hardware schedule in the following form:

Hardware Item

Quantity Size Reference Publication Type No.

Finish

Mfr.

Name and Catalog No.

Key Control Symbols

UL Mark (if fire rated and listed)

ANSI/BHMA

Finish Designation

1.7 INSTRUCTIONS

A. Hardware Set Symbols on Drawings: Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated on drawings by symbols.

Symbols for hardware sets consist of letters (e.g., "HW") followed by a number. Each number designates a set of hardware items applicable to a door type.

B. Keying information will be furnished to the Contractor by the COR.

1. Supply information regarding key control of cylinder locks to manufacturers of equipment having cylinder type locks. Notify COR immediately when and to whom keys or keying information is supplied. Return all such keys to the COR.

1.8 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. In text, hardware items are referred to by series, types, etc., listed in such specifications and standards, except as otherwise specified.

B. American National Standards Institute/Builders Hardware Manufacturers

Association (ANSI/BHMA):

A156.1-06 Butts and Hinges

A156.2-03 Bored and Pre-assembled Locks and Latches

A156.5-14 Cylinders and Input Devices for Locks.

A156.6-05 Architectural Door Trim

A156.13-05 Mortise Locks and Latches Series 1000

A156.16-08 Auxiliary Hardware

A156.18-06 Materials and Finishes

100% CONSTRUCTION DOCUMENTS

01/26/2026

Repair Exterior Features Envelope Maintenance & Repair

WALLA WALLA, WA

VA PROJECT NO. 687-20-101

08 71 00 - PAGE 3 OF 8

DOOR HARDWARE

A156.22-05 Door Gasketing and Edge Seal Systems

A156.30-03 High Security Cylinders

A250.8-03 Standard Steel Doors and Frames

PART 2 - PRODUCTS

2.1 BUTT HINGES

A. ANSI A156.1. Provide only three-knuckle hinges, except five-knuckle where the required hinge type is not available in a three-knuckle version (e.g., some types of swing-clear hinges). The following types of butt hinges shall be used for the types of doors listed, except where otherwise specified:

1. Exterior Doors: Type A2112/A5112 for doors 900 mm 3 feet wide or less and Type A2111/A5111 for doors over 900 mm (3 feet) wide.

Hinges for exterior outswing doors shall have non-removable pins.

Hinges for exterior fire-rated doors shall be of stainless steel material.

B. Provide quantity and size of hinges per door leaf as follows:

1. Doors 1210 mm 4 feet to 2260 mm (7 feet 5 inches high: 3 hinges minimum.

2. Doors up to 900 mm 3 feet wide, standard weight: 4.49 inch x 114 mm 4-1/2 inches x 4-1/2 inches) hinges.

3. Doors over 900 mm 3 feet to 1065 mm (3 feet 6 inches wide, standard weight: 5 inch x 114 mm (5 inches x 4-1/2 inches.

2.2 LOCKS AND LATCHES

A. Conform to ANSI A156.2. Locks and latches for doors 45 mm 1-3/4 inch thick or over shall have beveled fronts. Lock cylinders shall have not less than six pins. Cylinders for all locksets shall be removable core type. Cylinders shall be furnished with construction removable cores and construction master keys. Cylinder shall be removable by special key or tool. Construct all cores so that they will be interchangeable into the core housings of all mortise locks, rim locks, cylindrical locks, and any other type lock included in the Great Grand Master Key

System. Disassembly of lever or lockset shall not be required to remove core from lockset. All locksets or latches on double doors with fire label shall have latch bolt with 19 mm (3/4 inch) throw, unless shorter throw allowed by the door manufacturer’s fire label. Provide temporary keying device or construction core to allow opening and

100% CONSTRUCTION DOCUMENTS

01/26/2026

Repair Exterior Features Envelope Maintenance & Repair

WALLA WALLA, WA

VA PROJECT NO. 687-20-101

08 71 00 - PAGE 4 OF 8

DOOR HARDWARE

closing during construction and prior to the installation of final cores.

B. In addition to above requirements, locks and latches shall comply with following requirements:

1. Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13. Mortise locksets shall be series 1000, minimum Grade 2. All locksets and latchsets, except on designated doors in Psychiatric (Mental

Health) areas, shall have lever handles fabricated from cast stainless steel. Provide sectional (lever x rose) lever design matching hardware schedule. No substitute lever material shall be accepted. All locks and latchsets shall be furnished with 4.82 inch curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Lock function F02 shall be furnished with emergency tools/keys for emergency entrance. All lock cases installed on lead lined doors shall be lead lined before applying final hardware finish. Furnish armored fronts for all mortise locks. Where mortise locks are installed in high-humidity locations or where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.

2. Cylindrical Lock and Latch Sets: levers shall meet ADA (Americans with Disabilities Act) requirements. Cylindrical locksets shall be series 4000 Grade I. All locks and latchsets shall be furnished with 4.82 inch curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm

(7/8-inch) lip-to-center dimension. Provide lever design to match design selected by Architect or to match existing lever design.

Where two turn pieces are specified for lock F76, turn piece on inside knob shall lock and unlock inside knob, and turn piece on outside knob shall unlock outside knob when inside knob is in the locked position. (This function is intended to allow emergency entry into these rooms without an emergency key or any special tool.)

3. Auxiliary locks shall be as specified under hardware sets and conform to ANSI A156.36.

4. Locks on designated doors in Psychiatric (Mental Health) areas shall be paddle type with arrow projection covers and be UL

100% CONSTRUCTION DOCUMENTS

01/26/2026

Repair Exterior Features Envelope Maintenance & Repair

WALLA WALLA, WA

VA PROJECT NO. 687-20-101

08 71 00 - PAGE 5 OF 8

DOOR HARDWARE

Listed. Provide these locks with paddle in the down position on both sides of the door. Locks shall be fabricated of wrought stainless steel.

2.3 THRESHOLDS

A. Conform to ANSI A156.21, mill finish extruded aluminum, except as otherwise specified. In existing construction, thresholds shall be installed in a bed of sealant with ¼-20 stainless steel machine screws and expansion shields. In new construction, embed aluminum anchors coated with epoxy in concrete to secure thresholds. Furnish thresholds for the full width of the openings.

B. For thresholds at elevators entrances see other sections of specifications.

C. At exterior doors and any interior doors exposed to moisture, provide threshold with non-slip abrasive finish.

D. Provide with miter returns where threshold extends more than 12 mm 0.5 inch beyond face of frame.

2.4 WEATHERSTRIPS (FOR EXTERIOR DOORS)

A. Conform to ANSI A156.22. Air leakage shall not to exceed 0.50 CFM per foot of crack length (0.000774m3/s/m).

2.5 FINISHES

A. Exposed surfaces of hardware shall have ANSI A156.18, finishes as specified below. Finishes on all hinges, pivots, closers, thresholds, etc., shall be as specified below under "Miscellaneous Finishes." For field painting (final coat) of ferrous hardware, see Section 09 91 00, PAINTING.

B. 626 or 630: All surfaces on exterior and interior of buildings, except where other finishes are specified.

C. Miscellaneous Finishes:

1. Hinges --exterior doors: 626 or 630.

2. Hinges --interior doors: 652 or 630.

3. Pivots: Match door trim.

4. Door Closers: Factory applied paint finish. Dull or Satin Aluminum color.

5. Thresholds: Mill finish aluminum.

6. Cover plates for floor hinges and pivots: 630.

7. Other primed steel hardware: 600.

100% CONSTRUCTION DOCUMENTS

01/26/2026

Repair Exterior Features Envelope Maintenance & Repair

WALLA WALLA, WA

VA PROJECT NO. 687-20-101

08 71 00 - PAGE 6 OF 8

DOOR HARDWARE

2.6 BASE METALS

A. Apply specified U.S. Standard finishes on different base metals as following:

Finish Base Metal 652 Steel 626 Brass or bronze 630 Stainless steel

PART 3 - EXECUTION

3.1 HARDWARE HEIGHTS

A. For new buildings locate hardware on doors at heights specified below, with all hand-operated hardware centered within 864 mm 34 inches to

1200 mm (48 inches), unless otherwise noted:

B. Hardware Heights from Finished Floor:

1. Locksets and latch sets centerline of strike 1024 mm 40-5/16 inches.

2. Deadlocks centerline of strike 1219 mm 48 inches.

3. Push-pull latch to be 1024 mm 40-5/16 inches to centerline of strike.

4. Locate other hardware at standard commercial heights. Locate push and pull plates to prevent conflict with other hardware.

3.2 INSTALLATION

A. Hinge Size Requirements:

Door Thickness Door Width Hinge Height

45 mm 1-3/4 inch 900 mm (3 feet) and less

113 mm (4-1/2 inches)

45 mm (1-3/4 inch)

Over 900 mm (3 feet) but not more than 1200 mm ( 4 feet)

125 mm (5 inches)

35 mm (1-3/8 inch) (hollow core wood doors)

Not over 1200 mm (4 feet)

113 mm (4-1/2 inches)

B. Hinge leaves shall be sufficiently wide to allow doors to swing clear of door frame trim and surrounding conditions.

C. Hinges Required Per Door:

Door Description Number butts Doors 1500 mm (5 ft) or less in height

2 butts

100% CONSTRUCTION DOCUMENTS

01/26/2026

Repair Exterior Features Envelope Maintenance & Repair

WALLA WALLA, WA

VA PROJECT NO. 687-20-101

08 71 00 - PAGE 7 OF 8

DOOR HARDWARE

Door Description Number butts Doors over 1500 mm (5 ft) high and not over 2280 mm (7 ft 6 in) high

3 butts

Doors over 2280 mm 7 feet 6 inches) high

4 butts

Dutch type doors 4 butts Doors with spring hinges 1370 mm (4 feet 6 inches) high or less

2 butts

Doors with spring hinges over 1370 mm (4 feet 6 inches)

3 butts

D. Fastenings: Suitable size and type and shall harmonize with hardware as to material and finish. Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry. Fiber or rawl plugs and adhesives are not permitted.

All fastenings exposed to weather shall be of nonferrous metal.

E. After locks have been installed; show in presence of COR that keys operate their respective locks in accordance with keying requirements.

(All keys, Master Key level and above shall be sent Registered Mail to the Medical Center Director along with the bitting list. Also a copy of the invoice shall be sent to the COR for his records.) Installation of locks which do not meet specified keying requirements shall be considered sufficient justification for rejection and replacement of all locks installed on project.

3.3 FINAL INSPECTION

A. Installer to provide letter to VA Resident/Project Engineer that upon completion, installer has visited the Project and has accomplished the following:

1. Re-adjust hardware.

2. Evaluate maintenance procedures and recommend changes or additions, and instruct VA personnel.

3. Identify items that have deteriorated or failed.

4. Submit written report identifying problems.

3.4 HARDWARE SETS

A. Following sets of hardware correspond to hardware symbols shown on drawings. Only those hardware sets that are shown on drawings will be required. Disregard hardware sets listed in specifications but not shown on drawings.

100% CONSTRUCTION DOCUMENTS

01/26/2026

Repair Exterior Features Envelope Maintenance & Repair

WALLA WALLA, WA

VA PROJECT NO. 687-20-101

08 71 00 - PAGE 8 OF 8

DOOR HARDWARE

3.1 EXTERIOR SINGLE DOORS

HW-01

Each Door to Have: NON-RATED

1 Continuous Hinge

1 Entry Lock F11

Latch Protector (outswing dr)

1 Kick Plate J102

1 Threshold (outswing door) J32120 x SILICONE GASKET

1 Threshold (inswing door) ALUMINUM, PER ARCHITECTURAL DETAIL

1 Door Sweep R0Y416

1 Set Frame Seals R0Y164

1 Drip R0Y976

- - - E N D - - -

PART 1 - GENERAL
1.1 REFERENCE STANDARDS
A. BHMA A156.13 - Mortise Locks and Latches; 2022.
1.2 DESCRIPTION
A. Door hardware and related items necessary for complete installation and operation of doors.
1.3 RELATED WORK
A. Painting: Section 09 91 00, PAINTING.
1.4 GENERAL
A. All hardware shall comply with ABAAS, (Architectural Barriers Act Accessibility Standard) unless specified otherwise.
B. Hardware for application on metal and wood doors and frames shall be made to standard templates. Furnish templates to the fabricator of these items in sufficient time so as not to delay the construction.
C. The following items shall be of the same manufacturer, except as otherwise specified:
1. Mortise locksets.
2. Hinges for hollow metal and wood doors.
3. Surface applied overhead door closers.
4. Exit devices.
5. Floor closers.
1.5 MAINTENANCE MANUALS
A. In accordance with Section 01 00 00, GENERAL REQUIREMENTS Article titled "INSTRUCTIONS", furnish maintenance manuals and instructions on all door hardware. Provide installation instructions with the submittal documentation.
1.6 SUBMITTALS
A. Submittals shall be in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. Submit 6 copies of the schedule per Section 01 33 23. Submit 2 final copies of the final approved schedules to VAMC Locksmith as record copies (VISN ...
B. Hardware Schedule: AHC certified hardware consultant to prepare and submit hardware schedule in the following form:
1.7 INSTRUCTIONS
A. Hardware Set Symbols on Drawings: Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated on drawings by symbols. Symbols for hardware sets consist of letters (e.g...
B. Keying information will be furnished to the Contractor by the COR.
1. Supply information regarding key control of cylinder locks to manufacturers of equipment having cylinder type locks. Notify COR immediately when and to whom keys or keying information is supplied. Return all such keys to the COR.
1.8 APPLICABLE PUBLICATIONS
A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. In text, hardware items are referred to by series, types, etc., listed in such spec...
B. American National Standards Institute/Builders Hardware Manufacturers Association (ANSI/BHMA):
A156.1-06 Butts and Hinges
A156.2-03 Bored and Pre-assembled Locks and Latches
A156.5-14 Cylinders and Input Devices for Locks.
A156.6-05 Architectural Door Trim
A156.13-05 Mortise Locks and Latches Series 1000
A156.16-08 Auxiliary Hardware
A156.18-06 Materials and Finishes
A156.22-05 Door Gasketing and Edge Seal Systems
A156.30-03 High Security Cylinders
A250.8-03 Standard Steel Doors and Frames
PART 2 - PRODUCTS
2.1 BUTT HINGES
A. ANSI A156.1. Provide only three-knuckle hinges, except five-knuckle where the required hinge type is not available in a three-knuckle version (e.g., some types of swing-clear hinges). The following types of butt hinges shall be used for the types o...
1. Exterior Doors: Type A2112/A5112 for doors 900 mm 3 feet wide or less and Type A2111/A5111 for doors over 900 mm (3 feet) wide. Hinges for exterior outswing doors shall have non-removable pins. Hinges for exterior fire-rated doors shall be of sta...
B. Provide quantity and size of hinges per door leaf as follows:
1. Doors 1210 mm 4 feet to 2260 mm (7 feet 5 inches high: 3 hinges minimum.
2. Doors up to 900 mm 3 feet wide, standard weight: 4.49 inch x 114 mm 4-1/2 inches x 4-1/2 inches) hinges.
3. Doors over 900 mm 3 feet to 1065 mm (3 feet 6 inches wide, standard weight: 5 inch x 114 mm (5 inches x 4-1/2 inches.
2.2 LOCKS AND LATCHES
A. Conform to ANSI A156.2. Locks and latches for doors 45 mm 1-3/4 inch thick or over shall have beveled fronts. Lock cylinders shall have not less than six pins. Cylinders for all locksets shall be removable core type. Cylinders shall be furnished wi...
B. In addition to above requirements, locks and latches shall comply with following requirements:
1. Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13. Mortise locksets shall be series 1000, minimum Grade 2. All locksets and latchsets, except on designated doors in Psychiatric (Mental Health) areas, shall have lever handles fabricated from...
2. Cylindrical Lock and Latch Sets: levers shall meet ADA (Americans with Disabilities Act) requirements. Cylindrical locksets shall be series 4000 Grade I. All locks and latchsets shall be furnished with 4.82 inch curved lip strike and wrought box....
3. Auxiliary locks shall be as specified under hardware sets and conform to ANSI A156.36.
4. Locks on designated doors in Psychiatric (Mental Health) areas shall be paddle type with arrow projection covers and be UL Listed. Provide these locks with paddle in the down position on both sides of the door. Locks shall be fabricated of wrought ...
2.3 THRESHOLDS
A. Conform to ANSI A156.21, mill finish extruded aluminum, except as otherwise specified. In existing construction, thresholds shall be installed in a bed of sealant with ¼-20 stainless steel machine screws and expansion shields. In new construction, ...
B. For thresholds at elevators entrances see other sections of specifications.
C. At exterior doors and any interior doors exposed to moisture, provide threshold with non-slip abrasive finish.
D. Provide with miter returns where threshold extends more than 12 mm 0.5 inch beyond face of frame.
2.4 WEATHERSTRIPS (FOR EXTERIOR DOORS)
A. Conform to ANSI A156.22. Air leakage shall not to exceed 0.50 CFM per foot of crack length (0.000774m3/s/m).
2.5 FINISHES
A. Exposed surfaces of hardware shall have ANSI A156.18, finishes as specified below. Finishes on all hinges, pivots, closers, thresholds, etc., shall be as specified below under "Miscellaneous Finishes." For field painting (final coat) of ferrous har...
B. 626 or 630: All surfaces on exterior and interior of buildings, except where other finishes are specified.
C. Miscellaneous Finishes:
1. Hinges --exterior doors: 626 or 630.
2. Hinges --interior doors: 652 or 630.
3. Pivots: Match door trim.
4. Door Closers: Factory applied paint finish. Dull or Satin Aluminum color.
5. Thresholds: Mill finish aluminum.
6. Cover plates for floor hinges and pivots: 630.
7. Other primed steel hardware: 600.
2.6 BASE METALS
A. Apply specified U.S. Standard finishes on different base metals as following:
PART 3 - EXECUTION
3.1 HARDWARE HEIGHTS
A. For new buildings locate hardware on doors at heights specified below, with all hand-operated hardware centered within 864 mm 34 inches to 1200 mm (48 inches), unless otherwise noted:
B. Hardware Heights from Finished Floor:
1. Locksets and latch sets centerline of strike 1024 mm 40-5/16 inches.
2. Deadlocks centerline of strike 1219 mm 48 inches.
3. Push-pull latch to be 1024 mm 40-5/16 inches to centerline of strike.
4. Locate other hardware at standard commercial heights. Locate push and pull plates to prevent conflict with other hardware.
3.2 INSTALLATION
A. Hinge Size Requirements:
B. Hinge leaves shall be sufficiently wide to allow doors to swing clear of door frame trim and surrounding conditions.
C. Hinges Required Per Door:
D. Fastenings: Suitable size and type and shall harmonize with hardware as to material and finish. Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry. Fiber or rawl plugs an...
E. After locks have been installed; show in presence of COR that keys operate their respective locks in accordance with keying requirements. (All keys, Master Key level and above shall be sent Registered Mail to the Medical Center Director along with ...
3.3 FINAL INSPECTION
A. Installer to provide letter to VA Resident/Project Engineer that upon completion, installer has visited the Project and has accomplished the following:
1. Re-adjust hardware.
2. Evaluate maintenance procedures and recommend changes or additions, and instruct VA personnel.
3. Identify items that have deteriorated or failed.
4. Submit written report identifying problems.
3.4 HARDWARE SETS
A. Following sets of hardware correspond to hardware symbols shown on drawings. Only those hardware sets that are shown on drawings will be required. Disregard hardware sets listed in specifications but not shown on drawings.
3.1 EXTERIOR SINGLE DOORS
HW-01
Each Door to Have: NON-RATED
1 Continuous Hinge
1 Entry Lock F11
Latch Protector (outswing dr)
1 Kick Plate J102
1 Threshold (outswing door) J32120 x SILICONE GASKET
1 Threshold (inswing door) ALUMINUM, PER ARCHITECTURAL DETAIL
1 Door Sweep R0Y416
1 Set Frame Seals R0Y164
1 Drip R0Y976