View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--Multiple Award Task Order Contract (MATOC) Veterans Integrated Service Network (VlSN 19), newest first.
File Type Posted
C01 - Award Notice.docx DOCX document
36C25920R0104 P0015.docx DOCX document
Amendment 0012 - 36C25920R0104.docx DOCX document
Amendment 0011 - 36C25920R0104.docx DOCX document
Amendment 0010 - 36C25920R0104.docx DOCX document
Amendment 09 - 10-FA 18-314 Add01.pdf PDF
Amendment 09 - 03-Arch 18-314 Add01.pdf PDF
Amendment 09 - 06-Plumb 18-314 Add01.pdf PDF
Amendment 09 - 36C25920R0104.docx DOCX document
Amendment 09 - Submittal ID 00011r01 - Div 28 52 31 rev 1 Submittals.pdf PDF
Amendment 09 - 18-314_Addendum-01.pdf PDF
Amendment 09 - 01-Gen 18-314 Add01.pdf PDF
Amendment 09 - 09-Tech 18-314 Add01.pdf PDF
Amendment 09 - 04-IntD 18-314 Add01.pdf PDF
Amendment 09 - RFIs for MATOC Seed Project 36C25920R0104.docx DOCX document
Amendment 09 - 07-Mech 18-314 Add01.pdf PDF
Amendment 09 - 08-Elec 18-314 Add01.pdf PDF
Amendment 09 - SoilBearingInfo-ExistCondDWG_36-02-S1.pdf PDF
Amendment 09 - Interior Design Comments-221026.docx DOCX document
Amendment 09 - 02-Struct 18-314 Add01.pdf PDF
Amendment 09 - Infrastructure Standard for Telecommunications Spaces_with OIT Design Guide Templates_1 Jul 21.pdf PDF
Amendment 09 - 18-314 Specs 20221104.pdf PDF
Amendment 09 - Sub 00004r01 Response.pdf PDF
Amendment 0008 - 36C25920R0104.docx DOCX document
Amendment 0007 - 36C25920R0104.docx DOCX document
Amendment 0006 - 36C25920R0104.docx DOCX document
Amendment 0005 - 36C25920R0104.docx DOCX document
Amendment 0004 - 36C25920R0104.docx DOCX document
NEW - Calculation Worksheet for Self-Performed and Subcontracted Work.docx DOCX document
Amendment 0003 - 36C25920R0104.docx DOCX document
S04 - Site Visit Sign-In - 10-11-22.pdf PDF
Amendment 0002 - 36C25920R0104.docx DOCX document
Amendment 0001 - 36C25920R0104.docx DOCX document
Attachment (RFP Letter Seed Project - Updated 1-27-22).docx DOCX document
Attachment (Pricing Schedule).docx DOCX document
Attachment (Seed Project - Combined Drawings)_Part1.pdf PDF
Attachment (Seed Project - SLCVA Bldgs 14 1 and 7 Pre-Reno Asb Rpt_signed).pdf PDF
Attachment (Past Performance Questionnaire).docx DOCX document
Attachment (Seed Project - SP01 660-18-243 SOW).docx DOCX document
Attachment (Seed Project - Combined Specs).pdf PDF
36C25920R0104_1 - 9-30-2022.docx DOCX document
Attachment (Seed Project - Combined Drawings)_Part2.pdf PDF
Attachment (Seed Project - NESHAP).pdf PDF
Wage Determination UT20210085.pdf PDF
Attachment (Calculation Worksheet for Self-Peformed and Subcontracted Worksheet).docx DOCX document
Show all 45

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MA

MV

CO

EV

VE

AI

FOV

FOR

FOS

FP

LPG

NPW

NO

O

N

G

MPG

G

MPG

CA

CD

ACD

V

VBG

VBF

AV

AW

AW

ST

OST

GW

GW

S

W

ID

SPD

T

SCW

WS

140°

S

W

ST

CAP

"A"

BAT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISH FLOOR

BIL BASIC INSULATION LEVEL

BLDG BUILDING

BPIP BOILER PLANT

INSTRUMENTATION PANEL

BRKR BREAKER

BYP BY PASS

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HZ HERTZ

A/C AIR CONDITIONING

A/E ARCHITECT/ENGINEER

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR ARMORED

CABLE

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT, ADJOINING

ADO AUTOMATIC DOOR OPENER

AF AMPERE FRAME OR AMP FUSE

AFC ABOVE FINISHED COUNTER, AUTOMATIC

FREQUENCY CONTROL, OR

AVAILABLE FAULT CURRENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AH AMPERE HOUR

AHJ AUTHORITY HAVING JURISDICTION

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE

AMB OR A AMBIENT

AMP AMPERE

ARCH ARCHITECT

ASC AMPS SHORT CIRCUIT

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

1P SINGLE POLE

1PH SINGLE-PHASE

3P THREE POLE

3PH THREE-PHASE

3W THREE WIRE

4W FOUR WIRE

P POLE

PA PUBLIC ADDRESS

PB PANELBOARD, PULL BOX, OR

PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT UNIT

PCB POLYCHLORINATED BIPHENYL

PEC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PNL PANEL

POD POWER OPERATED DAMPER

PT POTENTIAL TRANSFORMER

PTRV POWER TYPE ROOF VENTILATION

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

SCC SHORT CIRCUIT CAPACITY

SES SERVICE ENTRANCE SECTION

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SPEC SPECIFICATION

SPST SINGLE POLE, SINGLE THROW

SURF SURFACE

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

G OR GND GROUND OR GENERATOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GTB GROUND TERMINAL BOX

IESNA ILLUMINATION ENGINEERING SOCIETY

OF NORTH AMERICA

IMC INTERMEDIATE METAL CONDUIT

INCAND INCANDESCENT

IR INFRARED

IWH INSTANTANEOUS WATER HEATER

W WATT

WH WATER HEATER

WP WEATHERPROOF

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LM LUMEN

LP LIGHT POLE

LPS LOW PRESSURE SODIUM

LRA LOCKED ROTOR AMPS

LTCP LOCAL TEMPERATURE CONTROL PANEL

LT LIGHT

LTG LIGHTING

LTG PNL LIGHTING PANEL

LTNG LIGHTNING

LV LOW VOLTAGE

XFER TRANSFER

XFMR TRANSFORMER

XP EXPLOSION PROOF

JB JUNCTION BOX

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT AMPERE

KVAH KILOVOLT AMPERE PER HOUR

KVAR KILOVOLT AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

KWHM KILOWATT HOUR METER

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC METAL-CLAD

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MG MOTOR GENERATOR

MH MANHOLE

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT PROTECTION

MLO MAIN LUGS ONLY

MT MOUNT

MTD MOUNTED

MTG MOUNTING

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

MVA MEGAVOLT-AMPERE

MW MEGAWATT

OC ON CENTER

OD OUTSIDE DIAMETER

OL OVERLOAD

N NEUTRAL

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NS NO SCALE

NTS NOT TO SCALE

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

REC RECESSED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

REQD REQUIRED

TC TIME CLOCK

TEL TELEPHONE

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

V VOLT

VA VOLT AMPERE

VAR VOLT AMPERE REACTIVE

VFD VARIABLE FREQUENCY DRIVE

VOLT VOLTAGE

UFD UNDERFLOOR DUCT

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

ABBREVIATIONS

A

B

C

C CONDUIT

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/

CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFE CONTRACTOR FURNISHED

EQUIPMENT

CHW CHILLED WATER

CHWP CHILLED WATER PUMP

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CLF CURRENT LIMITING FUSE

CLG CEILING

CMU CONCRETE MASONRY UNIT

COAX COAX CABLE

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CU COPPER

CU FT CUBIC FEET

DB DECIBEL OR DIRECT BURIAL

DC DIRECT CURRENT

DCP DIMMER CONTROL PANEL

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DIAG DIAGRAM

DISC DISCONNECT

DISTR DISTRIBUTION

DISTR PNL DISTRIBUTION PANEL

DN DOWN

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DRSW DOOR SWITCH

DS DISCONNECT SWITCH

DWG DRAWING

EC EMPTY CONDUIT

EG EQUIPMENT GROUND

EL ELEVATION

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMCP EMERGENCY MONITORING

CONTROL PANEL

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

ESMT EASEMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EXIST EXISTING

D

E

F

G

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FABL FIRE ALARM BELL

FABX FIRE ALARM BOX

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FI FILM ILLUMINATOR

FIXT FIXTURE

FLA FULL LOAD AMPS

FLEX FLEXIBLE METALLIC CONDUIT

FLUOR FLUORESCENT

FP FIRE PROTECTION

FT FEET OR FOOT

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

H

I

J

K

L

M

N

O

P

ANNOTATION

R

S

T

U

V

W

W

CU

M100

M100

MECHANICAL OR FIRE SPRINKLER PLAN NOTE CALL OUT

PLUMBING PLAN NOTE CALL OUT

ELECTRICAL OR FIRE ALARM PLAN NOTE CALL OUT

TECHNOLOGY PLAN NOTE CALL OUT

PLUMBING EQUIPMENT DESIGNATION

EQUIPMENT DESIGNATION TAG

OWNER FURNISHED, CONTRACTOR INSTALLED

EQUIPMENT DESIGNATION

NEW WORK TO EXISTING WORK CONNECTION POINT

DETAIL REFERENCE

SECTION CUT DESIGNATION

PIPING SYMBOLS

FIRE SPRINKLERS

FIRE PIPING

PENDENT SPRINKLER

UPRIGHT SPRINKLER

CONCEALED SPRINKLER

DRY PENDENT SPRINKLER

DRY SIDEWALL SPRINKLER

SIDEWALL SPRINKLER

WITH PDI SIZES, (A, B, C, D, & E)

WATER HAMMER ARRESTER (WHA)

FIRE DEPARTMENT CONNECTION

FIRE PUMP TEST HEADER

INSPECTOR'S TEST CONNECTION / AUXILIARY

DRAIN

SPRINKLER RISER

FLOOR DRAIN (FD), SIZE & TYPE

ROOF DRAIN (RD), SIZE & TYPE

NITROUS OXIDE OUTLET

NITROGEN OUTLET

MEDICAL VACUUM INLET

OXYGEN OUTLET

MEDICAL AIR OUTLET

FLOOR SINK (FS), SIZE & TYPE

NATURAL GAS ON ROOF (G)

SUMP OR SEWAGE PUMP DISCHARGE (SPD)

CONDENSATE DRAIN (CD)

INDIRECT DRAIN (ID)

NATURAL GAS (G)

NITROUS OXIDE (NO)

LIQUIFIED PETROLEUM GAS (LPG)

FIRE PROTECTION (FP)

WATER SERVICE (WS)

COMPRESSED AIR (CA)

NITROGEN (N)

MEDICAL AIR (MA)

OXYGEN (O)

DOMESTIC HOT WATER RECIRC.

SOIL PIPING - ABOVE FLOOR (S)

SOIL PIPING - BELOW FLOOR (S)

STORM DRAIN - ABOVE FLOOR (ST)

STORM DRAIN - BELOW FLOOR (ST)

ACID WASTE - ABOVE FLOOR (AW)

ACID WASTE - BELOW FLOOR (AW)

DOMESTIC COLD WATER

DOMESTIC HOT WATER

140° DOMESTIC HOT WATER (140°)

WASTE PIPING - ABOVE FLOOR (W)

WASTE PIPING - BELOW FLOOR (W)

GREASE WASTE - ABOVE FLOOR (GW)

GREASE WASTE - BELOW FLOOR (GW)

SOFTENED COLD WATER (SCW)

ACID VENT (AV)

VENT PIPING (V)

HOSE BIBB (HB)

NONFREEZE WALL HYDRANT (NW)

WALL CLEANOUT (WCO)

FLOOR CLEANOUT (FCO)

EXTERIOR CLEANOUT (ECO)

THERMOSTATIC MIXING VALVE

BACKFLOW PREVENTER

GAS PRESSURE REGULATOR

OVERFLOW STORM DRAIN - ABOVE FLOOR (OST)

NON POTABLE WATER (NPW)

FUEL OIL SUPPLY (FOS)

FUEL OIL RETURN (FOR)

FUEL OIL VENT (FOV)

AUXILIARY CONDENSATE DRAIN (ACD)

VENT BELOW GRADE (VBG)

VENT BELOW FLOOR (VBF)

CARBON DIOXIDE (CO)

MEDICAL VACUUM (MV)

EVACUATION (EV)

MEDICAL VACUUM EXHAUST (VE)

MEDICAL AIR INTAKE (AI)

TRAP PRIMER LINE (T)

WATER METER

MEDIUM PRESSURE NATURAL GAS (MPG)

MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG)

ELBOW DOWN WITH SHUT-OFF VALVE (SOV)

TEE DOWN WITH SHUT-OFF VALVE (SOV)

TEE UP WITH SHUT-OFF VALVE (SOV)

RECIRCULATION PUMP

DIRECTION OF FLOW

EXISTING PIPING TO REMAIN

EXISTING PIPING TO BE REMOVED

FLANGE CONNECTION

CLEANOUT

ELBOW DOWN

ELBOW UP

TEE DOWN

ELBOW UP WITH SHUT-OFF VALVE (SOV)

TEE UP

UNION

THERMOMETER

PRESSURE GAUGE

BALL VALVE

SHUTOFF VALVE

CHECK VALVE

PRESSURE REDUCING VALVE

REDUCER

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

Spur Design 312 SW 25th Street Oklahoma City, OK 73109 405.842.6100 www.spur-design.com

Mechanical/Electrical/Plumbing:

Foresite Group, LLC 3740 Davinci Court, Suite 100 Peachtree Corners, GA 30092 770.368.1399 www.fg-inc.net

Structural:

1, 7, 14

18-314

/4 /2

:4

:2

A

M

F-001

FIRE PROTECTION LEGEND

1 7RLC

EXPAND LINEN

DISTRIBUTION CENTER

SALT LAKE CITY VA MEDICAL CENTER

SALT LAKE CITY, UT 84148

11/04/2022

100% CONSTRUCTION DOCUMENTS

660-18-243

JRMNOVEMBER 04, 2022

SOILED LINEN

1C31B

MECH

1C31A

AREA OF DEMOLITION

2 3 4

SOILED LINEN

1C31B

MECH

1C31A

AREA OF WORK

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

Spur Design 312 SW 25th Street Oklahoma City, OK 73109 405.842.6100 www.spur-design.com

Mechanical/Electrical/Plumbing:

Foresite Group, LLC 3740 Davinci Court, Suite 100 Peachtree Corners, GA 30092 770.368.1399 www.fg-inc.net

Structural:

1, 7, 14

18-314

/4 /2

:4

:2

A

M

1-FX-101

BLDG 1 FIRE PROTECTION PLAN -

FIRST FLOOR

2 7RLC

EXPAND LINEN

DISTRIBUTION CENTER

SALT LAKE CITY VA MEDICAL CENTER

SALT LAKE CITY, UT 84148

11/04/2022

100% CONSTRUCTION DOCUMENTS

660-18-243

JRM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

V A

N A

C C E

S

SI

B

L E

V A

N A

C C E

S

SI

B

L E

Scale: 1/4" = 1'-0"

BLDG 1 FIRE PROTECTION DEMOLITION PLAN - FIRST FLOOR

Scale: 1/4" = 1'-0"

BLDG 1 FIRE PROTECTION PLAN - FIRST FLOOR

1. THE AREA OF WORK SHOWN IS ASSOCIATED

WITH AN OPERATING FACILITY THAT MUST

REMAIN IN SERVICE 24/7.

2. SEE SHEET G-100 FOR ADDITIONAL

INFORMATION REGARDING SCHEDULE AND

PHASING REQUIREMENTS. SCHEDULE WORK TO

MINIMIZE DISRUPTION OF SERVICES.

3. COORDINATE WORK SCHEDULE WITH THE

CONTRACTING OFFICER’S REPRESENTATIVE

(COR) BEFORE THE START OF WORK.

4. COORDINATE FIRE SPRINKLER WORK WITH

OTHER TRADES AND CONTRACTORS. VERIFY ALL

EXISTING CONDITIONS BEFORE THE START OF

WORK.

5. THE DEMOLITION DRAWINGS ARE SCHEMATIC.

CONTRACTOR RESPONSIBLE FOR FIELD

VERIFYING EXISTING DEMOLITION WORK PRIOR

TO SUBMISSION OF PROPOSAL.

1. REMOVE EXISTING FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

COORDINATE WITH ALL OTHER TRADES. VERIFY

ALL EXISTING CONDITIONS PRIOR TO

DEMOLITION.

2. DIVISION 21 CONTRACTOR TO PROVIDE AND

INSTALL FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

RECONNECT TO EXISTING AS REQUIRED.

3. DIVISION 21 CONTRACTOR TO PROVIDE AND

INSTALL FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

COORDINATE EXACT LOCATION WITH RELATED

TRADES.

4. DIVISION 21 CONTRACTOR TO REPOSITION

SPRINKLER HEADS AS REQUIRED.

0 4 8 16

N O R

TH

TRUE

0 4 8 16

N O R

TH

TRUE

NOVEMBER 04, 2022

7 8 8.3 9.1 10 11 11.9 12

'G

W

X

Y

Z

7.4 9.99

MECH RM

BA02

STAIR

BA03

EQUIP ROOM

BA05

ELEC

BA04

MAINTENANCE BENCH STOCK

BA06

AREA OF DEMOLITION

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

Spur Design 312 SW 25th Street Oklahoma City, OK 73109 405.842.6100 www.spur-design.com

Mechanical/Electrical/Plumbing:

Foresite Group, LLC 3740 Davinci Court, Suite 100 Peachtree Corners, GA 30092 770.368.1399 www.fg-inc.net

Structural:

1, 7, 14

18-314

/4 /2

:4

:2

A

M

7-FXD100

BLDG 7 FIRE PROTECTION DEMOLITION

PLAN - BASEMENT

3 7RLC

EXPAND LINEN

DISTRIBUTION CENTER

SALT LAKE CITY VA MEDICAL CENTER

SALT LAKE CITY, UT 84148

11/04/2022

100% CONSTRUCTION DOCUMENTS

660-18-243

JRM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

V A

N A

C C E

S

SI

B

L E

V A

N A

C C E

S

SI

B

L E

1. THE AREA OF WORK SHOWN IS ASSOCIATED

WITH AN OPERATING FACILITY THAT MUST

REMAIN IN SERVICE 24/7.

2. SEE SHEET G-100 FOR ADDITIONAL

INFORMATION REGARDING SCHEDULE AND

PHASING REQUIREMENTS. SCHEDULE WORK TO

MINIMIZE DISRUPTION OF SERVICES.

3. COORDINATE WORK SCHEDULE WITH THE

CONTRACTING OFFICER’S REPRESENTATIVE

(COR) BEFORE THE START OF WORK.

4. COORDINATE FIRE SPRINKLER WORK WITH

OTHER TRADES AND CONTRACTORS. VERIFY ALL

EXISTING CONDITIONS BEFORE THE START OF

WORK.

5. THE DEMOLITION DRAWINGS ARE SCHEMATIC.

CONTRACTOR RESPONSIBLE FOR FIELD

VERIFYING EXISTING DEMOLITION WORK PRIOR

TO SUBMISSION OF PROPOSAL.

1. REMOVE EXISTING FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

COORDINATE WITH ALL OTHER TRADES. VERIFY

ALL EXISTING CONDITIONS PRIOR TO

DEMOLITION.

Scale: 1/8" = 1'-0"

BLDG 7 FIRE PROTECTION DEMOLITION PLAN - BASEMENT 0 4 8 16

N O R

TH

W

X

Y

Z

7.4 9.99

'E

'C

'S

'A

'B

'T

2 1/2" FP FFB

1 1/2" FP FFB

OFFICE, CSCO

1B07A

OFFICE, DCSCO

1B07

ELEC

1B05

OFFICE

1B02B

OIT CLOSET

1B02E

OFFICE, MGMT ANALYSIS

1B02F

HAC

1B03

HAC

1B02A

STAIR

1BA

SHOWER/LOCKER

1B06A

TOILET, WOMEN

1B06

TOILET, MEN

1B04

SHOWER/LOCKER

1B04A

MAINTENANCE BENCH STOCK

1B02

WAREHOUSE

1B01

CORRIDOR

1B01B

ENTRY

1B00

CONFERENCE

1B01A

BREAK ROOM

1B01C

TELE/DATA

1B08

AUX

1B10

AREA OF DEMOLITION

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

Spur Design 312 SW 25th Street Oklahoma City, OK 73109 405.842.6100 www.spur-design.com

Mechanical/Electrical/Plumbing:

Foresite Group, LLC 3740 Davinci Court, Suite 100 Peachtree Corners, GA 30092 770.368.1399 www.fg-inc.net

Structural:

1, 7, 14

18-314

/4 /2

:4

:2

A

M

7-FXD101

BLDG 7 FIRE PROTECTION DEMOLITION

PLAN - FIRST FLOOR

4 7RLC

EXPAND LINEN

DISTRIBUTION CENTER

SALT LAKE CITY VA MEDICAL CENTER

SALT LAKE CITY, UT 84148

11/04/2022

100% CONSTRUCTION DOCUMENTS

660-18-243

JRM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

V A

N A

C C E

S

SI

B

L E

V A

N A

C C E

S

SI

B

L E

Scale: 1/8" = 1'-0"

BLDG 7 FIRE PROTECTION DEMO PLAN - FIRST FLOOR

1. THE AREA OF WORK SHOWN IS ASSOCIATED

WITH AN OPERATING FACILITY THAT MUST

REMAIN IN SERVICE 24/7.

2. SEE SHEET G-100 FOR ADDITIONAL

INFORMATION REGARDING SCHEDULE AND

PHASING REQUIREMENTS. SCHEDULE WORK TO

MINIMIZE DISRUPTION OF SERVICES.

3. COORDINATE WORK SCHEDULE WITH THE

CONTRACTING OFFICER’S REPRESENTATIVE

(COR) BEFORE THE START OF WORK.

4. COORDINATE FIRE SPRINKLER WORK WITH

OTHER TRADES AND CONTRACTORS. VERIFY ALL

EXISTING CONDITIONS BEFORE THE START OF

WORK.

5. THE DEMOLITION DRAWINGS ARE SCHEMATIC.

CONTRACTOR RESPONSIBLE FOR FIELD

VERIFYING EXISTING DEMOLITION WORK PRIOR

TO SUBMISSION OF PROPOSAL.

1. REMOVE EXISTING FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

COORDINATE WITH ALL OTHER TRADES. VERIFY

ALL EXISTING CONDITIONS PRIOR TO

DEMOLITION.

0 4 8 16

N O R

TH

W

X

Y

Z

7.4 9.99

1 2 3

MECH RM

BA02

STAIR

BA03

EQUIP ROOM

BA05

ELEC

BA04

MAINTENANCE BENCH STOCK

BA06

ELEV MACH

BA07

AREA OF WORK

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

Spur Design 312 SW 25th Street Oklahoma City, OK 73109 405.842.6100 www.spur-design.com

Mechanical/Electrical/Plumbing:

Foresite Group, LLC 3740 Davinci Court, Suite 100 Peachtree Corners, GA 30092 770.368.1399 www.fg-inc.net

Structural:

1, 7, 14

18-314

/4 /2

:4

:2

A

M

7-FX-100

BLDG 7 FIRE PROTECTION PLAN -

BASEMENT

5 7RLC

EXPAND LINEN

DISTRIBUTION CENTER

SALT LAKE CITY VA MEDICAL CENTER

SALT LAKE CITY, UT 84148

11/04/2022

100% CONSTRUCTION DOCUMENTS

660-18-243

JRM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

V A

N A

C C E

S

SI

B

L E

V A

N A

C C E

S

SI

B

L E

1. THE AREA OF WORK SHOWN IS ASSOCIATED

WITH AN OPERATING FACILITY THAT MUST

REMAIN IN SERVICE 24/7.

2. SEE SHEET G-100 FOR ADDITIONAL

INFORMATION REGARDING SCHEDULE AND

PHASING REQUIREMENTS. SCHEDULE WORK TO

MINIMIZE DISRUPTION OF SERVICES.

3. COORDINATE WORK SCHEDULE WITH THE

CONTRACTING OFFICER’S REPRESENTATIVE

(COR) BEFORE THE START OF WORK.

4. COORDINATE FIRE SPRINKLER WORK WITH

OTHER TRADES AND CONTRACTORS. VERIFY

ALL EXISTING CONDITIONS BEFORE THE START

OF WORK.

Scale: 1/8" = 1'-0"

BLDG 7 FIRE PROTECTION PLAN - BASEMENT

1. DIVISION 21 CONTRACTOR TO PROVIDE AND

INSTALL FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

RECONNECT TO EXISTING AS REQUIRED.

2. DIVISION 21 CONTRACTOR TO PROVIDE AND

INSTALL FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

COORDINATE EXACT LOCATION WITH RELATED

TRADES.

3. DIVISION 21 CONTRACTOR TO REPOSITION

SPRINKLER HEADS AS REQUIRED.

0 4 8 16

N O R

TH

W

X

Y

Z

7.4 9.99

'E

'C

'S

'A

'B

'T

2 1/2" FP FFB

1 1/2" FP FFB

1 2 3

1 2 3

1 2 3

OFFICE, CSCO

1B07A

STAIR

1BA

OFFICE, DCSCO

1B07

ELEC

1B05

HAC

1B03

HAC

1B02A

OFFICE

1B02B

OIT CLOSET

1B02E

SHOWER/LOCKER

1B04A

TOILET, MEN

1B04

TOILET, WOMEN

1B06

SHOWER/LOCKER

1B06A

CORRIDOR

1B00A

CHECK OUT

1B02C

MAINTENANCE BENCH STOCK

1B02

OFFICE, MGMT ANALYSIS

1B02F

LOGISTICS ADMIN

1B20

WAREHOUSE

1B01

BREAK ROOM

1B01C

CONFERENCE

1B01A

CORRIDOR

1B01B

ENTRY

1B00

TELE/DATA

1B08

AUX

1B10

AREA OF WORK

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

Spur Design 312 SW 25th Street Oklahoma City, OK 73109 405.842.6100 www.spur-design.com

Mechanical/Electrical/Plumbing:

Foresite Group, LLC 3740 Davinci Court, Suite 100 Peachtree Corners, GA 30092 770.368.1399 www.fg-inc.net

Structural:

1, 7, 14

18-314

/4 /2

:4

:2

A

M

7-FX-101

BLDG 7 FIRE PROTECTION PLAN -

FIRST FLOOR

6 7RLC

EXPAND LINEN

DISTRIBUTION CENTER

SALT LAKE CITY VA MEDICAL CENTER

SALT LAKE CITY, UT 84148

11/04/2022

100% CONSTRUCTION DOCUMENTS

660-18-243

JRM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

V A

N A

C C E

S

SI

B

L E

V A

N A

C C E

S

SI

B

L E

Scale: 1/8" = 1'-0"

BLDG 7 FIRE PROTECTION PLAN - FIRST FLOOR

1. THE AREA OF WORK SHOWN IS ASSOCIATED

WITH AN OPERATING FACILITY THAT MUST

REMAIN IN SERVICE 24/7.

2. SEE SHEET G-100 FOR ADDITIONAL

INFORMATION REGARDING SCHEDULE AND

PHASING REQUIREMENTS. SCHEDULE WORK TO

MINIMIZE DISRUPTION OF SERVICES.

3. COORDINATE WORK SCHEDULE WITH THE

CONTRACTING OFFICER’S REPRESENTATIVE

(COR) BEFORE THE START OF WORK.

4. COORDINATE FIRE SPRINKLER WORK WITH

OTHER TRADES AND CONTRACTORS. VERIFY

ALL EXISTING CONDITIONS BEFORE THE START

OF WORK.

1. DIVISION 21 CONTRACTOR TO PROVIDE AND

INSTALL FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

RECONNECT TO EXISTING AS REQUIRED.

2. DIVISION 21 CONTRACTOR TO PROVIDE AND

INSTALL FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

COORDINATE EXACT LOCATION WITH RELATED

TRADES.

3. DIVISION 21 CONTRACTOR TO REPOSITION

SPRINKLER HEADS AS REQUIRED.

4. DIVISION 21 CONTRACTOR TO PROVIDE AND

INSTALL SPRINKLER HEAD AT THE TOP OF THE

ELEVATOR SHAFT AS REQUIRED BY CODE.

0 4 8 16

N O R

TH

AREA OF DEMOLITION

2 3 4

CLEAN LINEN

BC09

OFFICE

BC04

AREA OF WORK

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

Spur Design 312 SW 25th Street Oklahoma City, OK 73109 405.842.6100 www.spur-design.com

Mechanical/Electrical/Plumbing:

Foresite Group, LLC 3740 Davinci Court, Suite 100 Peachtree Corners, GA 30092 770.368.1399 www.fg-inc.net

Structural:

1, 7, 14

18-314

/4 /2

:4

:2

A

M

14-FX-100

BLDG 14 FIRE PROTECTION PLAN -

BASEMENT

7 7RLC

EXPAND LINEN

DISTRIBUTION CENTER

SALT LAKE CITY VA MEDICAL CENTER

SALT LAKE CITY, UT 84148

11/04/2022

100% CONSTRUCTION DOCUMENTS

660-18-243

JRM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

V A

N A

C C E

S

SI

B

L E

V A

N A

C C E

S

SI

B

L E

Scale: 1/4" = 1'-0"

BLDG 14 FIRE PROTECTION DEMOLITION PLAN - BASEMENT

Scale: 1/4" = 1'-0"

BLDG 14 FIRE PROTECTION PLAN - BASEMENT

1. THE AREA OF WORK SHOWN IS ASSOCIATED

WITH AN OPERATING FACILITY THAT MUST

REMAIN IN SERVICE 24/7.

2. SEE SHEET G-100 FOR ADDITIONAL

INFORMATION REGARDING SCHEDULE AND

PHASING REQUIREMENTS. SCHEDULE WORK TO

MINIMIZE DISRUPTION OF SERVICES.

3. COORDINATE WORK SCHEDULE WITH THE

CONTRACTING OFFICER’S REPRESENTATIVE

(COR) BEFORE THE START OF WORK.

4. COORDINATE FIRE SPRINKLER WORK WITH

OTHER TRADES AND CONTRACTORS. VERIFY ALL

EXISTING CONDITIONS BEFORE THE START OF

WORK.

5. THE DEMOLITION DRAWINGS ARE SCHEMATIC.

CONTRACTOR RESPONSIBLE FOR FIELD

VERIFYING EXISTING DEMOLITION WORK PRIOR

TO SUBMISSION OF PROPOSAL.

1. REMOVE EXISTING FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

COORDINATE WITH ALL OTHER TRADES. VERIFY

ALL EXISTING CONDITIONS PRIOR TO

DEMOLITION.

2. DIVISION 21 CONTRACTOR TO PROVIDE AND

INSTALL FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

RECONNECT TO EXISTING AS REQUIRED.

3. DIVISION 21 CONTRACTOR TO PROVIDE AND

INSTALL FIRE SPRINKLER PIPING AND

ASSOCIATED ACCESSORIES AS REQUIRED.

COORDINATE EXACT LOCATION WITH RELATED

TRADES.

4. DIVISION 21 CONTRACTOR TO REPOSITION

SPRINKLER HEADS AS REQUIRED.

0 4 8 16

N O R

TH

TRUE

0 4 8 16

N O R

TH

Sheets
F-001 - FIRE PROTECTION LEGEND
1-FX-101 - BLDG 1 FIRE PROTECTION PLAN - FIRST FLOOR
7-FXD100 - BLDG 7 FIRE PROTECTION DEMOLITION PLAN - BASEMENT
7-FXD101 - BLDG 7 FIRE PROTECTION DEMOLITION PLAN - FIRST FLOOR
7-FX-100 - BLDG 7 FIRE PROTECTION PLAN - BASEMENT
7-FX-101 - BLDG 7 FIRE PROTECTION PLAN - FIRST FLOOR
14-FX-100 - BLDG 14 FIRE PROTECTION PLAN - BASEMENT

File details come from the government source that posted it. Updated .