A. REFER TO SPECIFICATION SECTION 090600
SCHEDULE OF FINISHES FOR DEFINITIONS OF EACH
FINISH.
B. ALL WALLS SHALL BE PAINTED P-01, UNLESS NOTED
OTHERWISE.
C. ALL HOLLOW-METAL FRAMES TO BE PAINTED P-02,
UNLESS NOTED OTHERWISE.
D. ALL GYPSUM BOARD CEILINGS TO BE PAINTED P-04,
UNLESS NOTED OTHERWISE.
E. ALL COUNTERTOPS TO BE SS-01.
F. ALL CASEWORK LAMINATE TO BE HPL-01.
G. CUT ALL FLOORING TIGHT TO DOOR FRAME. SEAL
JOINTS BETWEEN DOOR FRAME AND FLOORING WITH
COLOR-MATCHED SEALANT.
H. WHERE EXISTING SPACES ARE SCHEDULED TO
RECEIVE NEW PAINT, CONTRACTOR SHALL PATCH
AND REPAIR WALLS TO LEVEL 4 FINISH PRIOR TO
PAINTING.
I. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED
AND INSTALLED.
J. CONTRACTOR SHALL INSTALL A SIGN AT THE ENTRY
SIDE OF EACH DOOR FOR EACH SPACE LISTED IN
SIGNAGE SCHEDULE. AT STAIRS, PROVIDE SIGN ON
ENTRY AND EGRESS SIDES OF DOOR.
K. VERIFY ROOM NUMBERS AND NAMES OF ROOMS TO
BE DISPLAYED ON SIGNAGE WITH VA COR PRIOR TO
FABRICATION.
L. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED
LETTERS AND BRAILLE.SIGNAGE SHALL BE LOCATED
AT LATCH SIDE OF DOOR AND MUST BEMOUNTED IN
ACCORDANCE WITH ALL CURRENT ADA STANDARDS.
M. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON
LATCH SIDE OF DOOR PER MOUNTING STANDARDS,
SIGNS SHALL BE INSTALLED PER CURRENT ADA
STANDARDS ON NEAREST ADJACENT WALL.
STAINLESS STEEL TOP CAP
PREFABRICATED
COVE FORM
SHEET FLOORING
AS SCHEDULED
6" U
N O
ALL SEAMS, COVES, AND
CORNERS SHALL BE SMOOTH
ADHESIVE
RESILIENT FLOORING
SEALED CONCRETE
REDUCER STRIP
SCHLUTER - DECO TRANSISTION
LUXURY VINYL TILE
SHEET VINYL
ADHESIVE
DOOR
TILE
RESILIENT FLOORING
MARBLE THRESHOLD
SETTING BED
ADHESIVE
ADHESIVE
RESILIENT FLOORING
FLOOR TILE
REDUCER STRIP
BY JOHNSONITE
FLOOR TO BE
FEATHERED AND SLOPED
TO MEET CARPET AT
SAME HEIGHT
SLOPE FLOOR MINIMUM 1/4" PER FOOT
TO SHOWER DRAIN
WATERPROOFING MEMBRANE - INSTALL
PER MANUFACTURER'S INSTRUCTIONS
TILE
EXISTING SHOWER DRAIN
BACKER BOARD
TILE
ALTERNATING TILES - (1) CT-4, (2) CT-3, (1) CT-4, (2) CT-3
ALTERNATING TILES - (2) CT-4, (1) CT-3, (2) CT-4, (1) CT-3
REPEATING TILE - CT-5
REPEATING TILE - CT-5
REPEATING TILE - CT-2
ALTERNATING TILES - (1) CT-4, (2) CT-3, (1) CT-4, (2) CT-3
ALTERNATING TILES - (2) CT-4, (1) CT-3, (2) CT-4, (1) CT-3
REPEATING TILE - CT-5
REPEATING TILE - CT-5
REPEATING TILE - CT-2
ALTERNATING TILES - (2) CT-4, (1) CT-3, (2) CT-4, (1) CT-3
REPEATING TILE - CT-5
REPEATING TILE - CT-5
V
IF
TYPE: SN-01
TYPE: SN-02
SIGNAGE TYPES:
SN-01
ROOM SIGN WITH
NUMBER ONLY
COORDINATE DESIGN W/ COR TO
MATCH SIGNAGE STANDARDS
SN-02
ROOM SIGN WITH
NAME AND NUMBER
COORDINATE DESIGN W/ COR TO
MATCH SIGNAGE STANDARDS
SN-03
FIRE EXTINGUISHER CABINET
SIGN (PROVIDE 1 AT EACH FEC)
COORDINATE DESIGN W/ COR TO
MATCH SIGNAGE STANDARDS
SN-04
TOILET ROOM SIGN COORDINATE DESIGN W/ COR TO
MATCH SIGNAGE STANDARDS
SN-05
STAIR SIGN COORDINATE DESIGN W/ COR TO
MATCH SIGNAGE STANDARDS
2" FROM DOOR FRAME
NEW SIGNAGE
CORRIDOR SIDE
Revisions: Date
Drawing Title
Approved: Project Director
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
Spur Design 312 SW 25th Street Oklahoma City, OK 73109 405.842.6100 www.spur-design.com
Mechanical/Electrical/Plumbing:
Foresite Group, LLC 3740 Davinci Court, Suite 100 Peachtree Corners, GA 30092 770.368.1399 www.fg-inc.net
Structural:
/3 /2
:4
:5
P
M
IF001
INTERIOR FINISH SCHEDULE AND
DETAILS
1 1LG/CK
EXPAND LINEN
DISTRIBUTION CENTER
SALT LAKE CITY VA MEDICAL CENTER
SALT LAKE CITY, UT 84148
NOVEMBER 04, 2022
100% CONSTRUCTION DOCUMENTS
660-18-24318-314
1, 7, 14
CK
ROOM FINISH SCHEDULE
ROOM NO. NAME FLOOR BASE WALL CEILING REMARKS
BLDG 7 - BASEMENT
BA02 MECH RM SC-01 N/A P-01 N/A
BA03 STAIR SC-01 RB-01 P-01 N/A
BA05 EQUIP ROOM SC-01 RB-01 P-01 N/A
BA06 MAINTENANCE BENCH STOCK SC-01 RB-01 P-01 N/A
BA07 ELEV MACH SC-01 N/A P-01 N/A
BLDG 7 - 1ST FLOOR
1B00 ENTRY LVT-01 RB-01 P-01 ACT-01
1B00A CORRIDOR LVT-01 RB-01 P-01 ACT-01
1B01 WAREHOUSE SC-01 RB-01 P-01 N/A
1B01A CONFERENCE CPT-01 RB-01 P-01 ACT-01
1B01B CORRIDOR LVT-01 RB-01 P-01 ACT-01
1B01C BREAK ROOM LVT-01 RB-01 P-01 ACT-01
1B02 MAINTENANCE BENCH STOCK SC-01 RB-01 P-01 N/A
1B02B OFFICE CPT-01 RB-01 P-01 ACT-01
1B02E OIT CLOSET SC-01 RB-01 P-01 ACT-01
1B02F OFFICE, MGMT ANALYSIS CPT-01 RB-01 P-01 ACT-01
1B02G OFFICE, MGMT ANALYSIS CPT-01 RB-01 P-01 ACT-01
1B04 TOILET, MEN CT-01 CT-02 P-01 P-03
1B04A SHOWER/LOCKER CT-01 CT-02 P-01 P-03
1B06 TOILET, WOMEN CT-01 CT-02 P-01 P-03
1B06A SHOWER/LOCKER CT-01 CT-02 P-01 P-03
1B07 OFFICE, DCSCO CPT-01 RB-01 P-01 ACT-01
1B07A OFFICE, CSCO CPT-01 RB-01 P-01 ACT-01
1B20 LOGISTICS ADMIN CPT-01 RB-01 P-01 ACT-01
BLDG 14 - BASEMENT
BC04 OFFICE SC-02 RB-01 P-01 ACT-01
BC09 CLEAN LINEN SC-02 RB-01 P-01 ACT-01
BLDG 1 - FIRST FLOOR
1C31B SOILED LINEN SC-02 RB-01 P-01 ACT-01
Scale: 3" = 1'-0"
TYPICAL COVE BASE DETAIL
Scale: 1" = 1'-0"
TYPICAL FLOOR TRANSITION DETAIL - CONCRETE TO RESILIENT
Scale: 1" = 1'-0"
TYPICAL FLOOR TRANSITION DETAIL - LVT TO SV
Scale: 1" = 1'-0"
TYPICAL FLOOR TRANSITION DETAIL - TILE TO RESILIENT AT DOOR
Scale: 1" = 1'-0"
TYPICAL FLOOR TRANSITION DETAIL - TILE TO RESILIENT FLOOR
Scale: 1 1/2" = 1'-0"
TYPICAL SHOWER FLOOR DETAIL
FINISH ABBREVIATIONS
AB ALUMINUM WALL BASE
ACT ACOUSTICAL CEILING TILE
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
AP ACOUSTIC WALL PANEL
BBT BIOBASED TILE
CG CORNER GUARD
CJ CONTROL JOINT
CMU CONCRETE MASONRY UNIT
CON CONCRETE FLOORING
CR CARD READER
CPT CARPET
CS CULTURED STONE
CT CERAMIC TILE
DG DOOR FRAME GUARD
EG END WALL GUARD
EM ENTRY MAT SYSTEM
EPX EPOXY FLOORING
EX EXISTING
EXJ EXPANSION JOINT
EXP EXPOSED
F FABRIC
FRP FIBERGLASS REINFORCED PANELS
GLS DECORATIVE GLASS
G GROUT
GYP GYPSUM WALL BOARD
HR HAND RAIL
LAM PLASTIC LAMINATE
LF LINEAR FEET (FOOT)
LIN LINOLEUM SHEET / TILE
LVT LUXURY VINYL TILE
MB MOLDED WALL BASE
MTL METAL
MISC MISCELLANEOUS
NA NOT APPLICABLE
NS NATURAL STONE
P PAINT
PNT PAINT
PFIN PREFINISHED
QTZ QUARTZ COUNTERTOP
RB RESILIENT WALL BASE
RPS RESIN PANEL SYSTEM
RM ROCK MULCH
RVT RESILIENT VINYL TILE
SC SEALER/COATING
SF SQUARE FEET (FOOT)
SS SOLID SURFACE
SST STAINLESS STEEL
SSV SPECIALTY SHEET VINYL
ST STAIN
SV SHEET VINYL
SVT SPECIALTY VINYL TILE
T TILE FLOORING/ WALL / WALL
BASE (CERAMIC, PORCELAIN,
GLASS)
TP TOLIET PARTITION
TR DECORATIVE WOOD TRIM /
CROWN / BASE MOLDING
TS TRANSITION STRIP
TYP TYPICAL
TZ TERAZZO FLOORING
UFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VET VINYL ENCHANCED TILE
VIF VERIFY IN FIELD
VWC VINYL WALL COVERING
WD WOOD FLOORING
WDP WOOD PANELING / WAINSCOT
WP WALL PROTECTION
WR WHITEROCK
Scale: 1" = 1'-0"
TYPICAL TILE PATTERN - SHOWERS
Scale: No Scale
SIGNAGE STANDARDS
Scale: 1/4" = 1'-0"
TYPICAL SIGNAGE LOCATION
SIGNAGE SCHEDULE
ROOM NO. NAME Signage Type
BLDG 7 - BASEMENT
BA02 MECH RM SN-02
BA03 STAIR SN-05
BA04 ELEC SN-02
BA05 EQUIP ROOM SN-02
BA06 MAINTENANCE BENCH STOCK SN-01
BA07 ELEV MACH SN-02
BLDG 7 - 1ST FLOOR
1B01 WAREHOUSE SN-02
1B01A CONFERENCE SN-02
1B01C BREAK ROOM SN-02
1B02 MAINTENANCE BENCH STOCK SN-02
1B02A HAC SN-02
1B02B OFFICE SN-02
1B02E OIT CLOSET SN-02
1B02F OFFICE, MGMT ANALYSIS SN-02
1B02G OFFICE, MGMT ANALYSIS SN-02
1B03 HAC SN-02
1B04 TOILET, MEN SN-04
1B05 ELEC SN-01
1B06 TOILET, WOMEN SN-04
1B07 OFFICE, DCSCO SN-02
1B07A OFFICE, CSCO SN-02
1B20 LOGISTICS ADMIN SN-02
1BA STAIR SN-05
BLDG 14 - BASEMENT
BC04 OFFICE SN-01
BC09 CLEAN LINEN SN-02
BLDG 1 - FIRST FLOOR
1C31B SOILED LINEN SN-02
0 1 2
0 1 2
0 1 2
0 1 2
0 1 2
0 1 2
0 1 2