This federal contract opportunity notice seeks proposals from qualified Service Disabled Veteran Owned Small Businesses to provide construction services for the Construct New Clinical Lab Expansion project located at the H.H. McGuire VA Medical Center in Richmond, Virginia. The project scope includes the partial renovation and addition of approximately 18,050 square feet to the existing medical center building. Construction drawings and specifications will be provided by AES Group, Inc. Proposals are due on or about August 15, 2019. The contract award is set aside for SDVOSBs and has an estimated value between $5-10 million. The selected contractor must complete all work within 680 calendar days of receiving the notice to proceed, including final inspection and cleanup.
36C24619B0039 S02 TELECOM_Bid Documents.pdf
View the file
Other files for this federal contract opportunity
Show all 39
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIAL SYSTEMS SYMBOLS ABBREVIATIONS
SYMBOL DESCRIPTION
W
WALL-MOUNTED TELEPHONE OUTLET 1 PORT
CONFIGURATION FACEPLATE - MOUNTED 48" AFF
UNLESS OTHERWISE NOTED
DATA OUTLET WITH (2)RJ45 JACKS - MOUNTED 18"
AFF UNLESS OTHERWISE NOTED
S
PUBLIC ADDRESS SPEAKER RECESSED- CEILING
MOUNTED
I
INTERCOM STATION - WALL MOUNTED
DOOR SWITCH/CONTACT TO MONITOR STATUS OF
DOOR (OPEN/CLOSED) ALARM SENSING DEVICE
(PACS SYSTEM COMPONENT)
REQUEST TO EXIT SENSOR FOR DOOR
RELEASE (PACS SYSTEM COMPONENT)
CLPS COMMUNICATIONS LIGHTNING PROTECTION
SYSTEM
CFM CONSTRUCTION & FACILITIES MANAGEMENT
CMLPS COMMUNICATION MAIN LIGHTNING
PROTECTION SYSTEM
DM DESIGN MANUAL
EDM ELECTRICAL DESIGN MANUAL
EGB EXTERNAL GROUNDING BUSBAR
EGC EARTH GROUNDING CONDUCTOR
EMI ELECTROMAGNETIC INTERFERENCE
FDU FIBER DISTRIBUTION UNIT
FLPS FACILITY LIGHTNING PROTECTION SYSTEM
FMS FACILITIES MANAGEMENT SERVICE
IP INTERNET PROTOCOL
IT INFORMATION TECHNOLOGY
LAN LOCAL AREA NETWORK
WAN WIDE AREA NETWORK
MCR MAIN COMPUTER ROOM
MCOR MAIN COMPUTER OPERATORS ROOM
MATV MASTER ANTENNA TELEVISION
MID MOTION INTRUSION DETECTOR
MM MULTIMODE
OIT OFFICE OF INFORMATION & TECHNOLOGY
PACS PHYSICAL ACCESS CONTROL SYSTEM
PAS PUBLIC ADDRESS
PBX PRIVATE BRANCH EXCHANGE
PDU POWER DISTRIBUTION UNIT
POTS PLAIN OLD TELEPHONE SYSTEM
PSDM PHYSICAL SECURITY DESIGN MANUAL
RFI RADIO FREQUENCY INTERFERENCE
RTLS REAL-TIME LOCATION SYSTEM
RU RACK UNIT
SM SINGLE MODE
SMCS SPECIAL MEDICAL COMMUNICATIONS SYSTEMS
SDO SECURED DOOR OPENING
TASTS TELECOMMUNICATIONS AND SPECIAL
TELECOMMUNICATIONS SYSTEMS
TBB TELECOMMUNICATIONS BONDING BACKBONE
TCO TELECOMMUNICATIONS OUTLETS
TER TELEPHONE EQUIPMENT ROOM
TGB TELECOMMUNICATIONS GROUND BAR
TIP TELECOMMUNICATIONS INFRASTRUCTURE PLANT
TR TELECOMMUNICATIONS ROOM
UPS UNINTERRUPTIBLE POWER SUPPLY
VA VETERANS AFFAIRS
VACO VETERANS ADMINISTRATION CENTRAL OFFICE
VOIP VOICE OVER INTERNET PROTOCOL
WAP
CR CARD READER, PROXIMITY READER TYPE.
MOUNTED 42" AFF UNLESS OTHERWISE NOTED
# - CARD READER NUMBER (PACS SYS. CMPNT.)
SPECIAL SYSTEM STANDARDS
INDUSTRY STANDARDS:
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ELECTRONIC INDUSTRIES ALLIANCE (EIA)
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
BUILDING INDUSTRY CONSULTING SERVICE INTERNATIONAL (BICSI)
TELECOMMUNICATIONS DISTRIBUTION METHODS MANUAL (TDMM)
DESIGN STANDARDS:
VOICE AND DATA COMMUNICATION CABLING REV 1.0
SPECIAL SYSTEM SCOPE
VOICE SERVICE SHALL BE VOIP, HOWEVER THERE SHALL
ALWAYS BE A QUANTITY OF POTS COPPER PAIRS TO BE
DISTRIBUTED FROM MCR TO EACH OF THE TRS. OIT TO
DETERMINE.
CELL WITH "YES" MARKING INDICATES SYSTEM IS PART OF
SCOPE:
OSP COMMUNICATIONS SYSTEMS AND
EQUIPMENT:
PART
OF
SCOPE:
DATA: VOIP YES
DATA: LAN YES
DATA: WAN YES
FMS COMMUNICATIONS SYSTEMS AND
EQUIPMENT:
PART
OF
SCOPE:
NURSE CALL AND/OR CODE BLUE NO
TELEVISION (MASTER ANTENNA [MATV]
NO
COMMUNITY ANTENNA [CATV]
NO
CLOSED CIRCUIT [CCTV] [FOR EDUCATION] &
SATELLITE TV [SATV]) NO
RADIO (PAGING [CODE BLUE, EMERGENCY &
ROUTINE]) NO
MICROWAVE, SATELLITE RADIO/TELEPHONE &
RADIO ENTERTAINMENT
NO
PUBLIC ADDRESS:
*OVERHEAD PAGING,
*MASS NOTIFICATION,
*INTERCOMMUNICATIONS [INTERCOM])
YES
NO
NO
PHYSICAL SECURITY MANAGEMENT:
*ACCESS CONTROL (PACS)
*MOTION INTRUSION DETECTION
*DURESS AND/OR PANIC ALARM
*SECURITY SURVEILLANCE TELEVISION [SSTV])
YES
NO
NO
YES
PATIENT, STAFF AND ASSET MONITORING
(MEDICAL TELEMETRY, PATIENT/STAFF
LOCATION, AND CARDIAC)
NO
ENERGY MANAGEMENT NO
EMERGENCY (FIRE ALARM/MASS NOTIFICATION,
POLICE, AND DISASTER) NO
TELEPHONE/DATA OUTLET WITH 4 PORT
CONFIGURATION FACEPLATE. TWO ACTIVE AND
TWO SPARE. MOUNTED AT 18" AFF UNLESS
OTHERWISE SPECIFIED.
TV
TV OUTLET - COAX CABLE JACK OUTLET.
MOUNTED AT CLOSE PROXIMITY TO TV.
WIRELESS ACCESS POINT OUTLET - CEILING
MOUNTED, SEE TELECOM DETAILS.
GENERAL
1. THE TERM "PROVIDE", WHERE USED HEREIN, SHALL MEAN THE SAME AS:
SURVEYED, FURNISHED, INSTALLED, AND TESTED BY CONTRACTOR.
2. THE TIP MUST BE INSTALLED IN ACCORDANCE WITH CFM'S MASTER
CONSTRUCTION SPECIFICATIONS (PG-18-1). CONTRACTOR TO PROVIDE
EQUIPMENT AND SYSTEM THAT MEET THE DESIGN INTENT IN TERMS OF
PERFORMANCE, QUALITY, AND COST.
3. EQUIPMENT REFERENCE MANUAL (PG-18-5) SHALL BE USED FOR PLANNING
AND DEVELOPING REQUIREMENTS FOR CONTRACTOR PURCHASED AND
INSTALLED EQUIPMENT
4. QUANTITY OF CABINETS AND RACKS ALLOCATED WILL SUPPORT THE IT
EQUIPMENT NEEDED FOR THE ANTICIPATED NUMBER OF LINES AND PORTS,
PLUS BOTH 50 PERCENT EXPECTED EXPANSION AND SPACE FOR
ANTICIPATED SYSTEMS REDUNDANCY.
5. SERVICES PASSING THROUGH AREAS OF REMODELING AND / OR
CONSTRUCTION SHALL BE MAINTAINED THROUGHOUT THE CONSTRUCTION
PERIOD.
6. EQUIPMENT AND SYSTEMS INSTALLED SHALL BE FULLY COMPATIBLE AND
FUNCTIONAL WITH EXISTING FACILITY COMPONENTS AND SYSTEMS TO
WHICH IT INTERFACES.
7. CONDUITS INSIDE BUILDING SHALL NOT EXCEED 100FT BETWEEN
PULLBOXES. CABLES CONNECTING WORKSTATIONS SHALL NOT BE LONGER
THAN 295 FEET (90 M)
8. CONDUIT ENCLOSING OPTICAL FIBER CABLING SHALL HAVE A MINIMUM
CONDUIT BEND RADIUS OF 10 TIMES THE INTERNAL DIAMETER OF CONDUIT
9. THE MINIMUM SIZE CONTROL WIRING SHALL BE NOT LESS THAN NO. 14 AWG
10.PLENUM, CMP, RATED CABLE SHALL BE PROVIDED IN ALL AIR-HANDLING
PLENUM LOCATIONS. NON-PLENUM, CM OR CMR, CABLE MAY BE PROVIDED IN
ALL OTHER AREAS
11. ALL BALANCED TWISTED PAIR CABLING SHALL BEAR CMP (PLENUM RATED),
CM/CMR (RISER RATED) AND/OR APPROPRIATE MARKINGS FOR THE
ENVIRONMENT IN WHICH THEY ARE INSTALLED.
12. ALL FIBER OPTIC CABLING SHALL BEAR OFNP (PLENUM RATED), OFNR (RISER
RATED) AND/OR APPROPRIATE MARKINGS FOR THE ENVIRONMENT IN WHICH
THEY ARE INSTALLED.
13.GROUNDING CONDUCTORS SHALL BE INSULATED STRANDED COPPER
EXCEPT SIZES 10AWG AND SMALLER WHICH SHALL BE SOLID COPPER.
INSULATION COLOR SHALL BE CONTINUOUS GREEN FOR ALL EQUIPMENT
GROUNDING CONDUCTORS EXCEPT WIRE 4AWG AND LARGER PER NEC.
14.INSTALLATIONS, MATERIALS, EQUIPMENT AND WORKMANSHIP SHALL
CONFORM TO AND BE INSPECTED, AND TESTED IN ACCORDANCE WITH THE
SPECIFICATIONS AND DRAWINGS AND ALL APPLICABLE PROVISIONS OF THE
FOLLOWING GOVERNING RULES, REGULATIONS, CODES, AND STANDARDS
INCLUDING ALL APPLICABLE ADDENDA:
A. ANSI/NEC (NFPA 70)
B. NESC (IEEE)
C. NATIONAL LIFE SAFETY CODE (NFPA 101)
D. ASTM STANDARDS
E. IEEE STANDARDS
F. NEMA STANDARDS
G. ANSI/TIA - TELECOMMUNICATIONS CABLING STANDARDS INCLUDING,
BUT NOT LIMITED TO, 568-C.0, 568-C.1, 568-B.2, 568-C.3, 569-B, 598-C, 455
SERIES, 492 SERIES, 526 SERIES, 604 SERIES, 606, 607,758-A, TSB-140,
FIP 174, FIP 175, FIP 176, S-83-596, S-87-640
H. FCC CODE OF FEDERAL REGULATIONS (CFR)
I. APPLICABLE STATE OF VIRGINIA CODES INCLUDING VAMC AND
DEPARTMENT OF LABOR RULES AND REGULATIONS
J. APPLICABLE MUNICIPAL CODES
K. APPLICABLE CODES AND REGULATIONS OF OTHER AUTHORITIES
HAVING LAWFUL JURISDICTION PERTAINING TO THE WORK REQUIRED
L. UNDERWRITERS LABORATORIES (UL)
15. THICK BLACK LINES INDICATE NEW AND LIGHT SCREENED LINES INDICATE
EXISTING UNLESS OTHERWISE NOTED.
16. ALL WIRING TO BE ROUTED CONCEALED, UNLESS OTHERWISE NOTED.
TELECOMMUNICATIONS
1. TELECOMMUNICATION AND SPECIAL TELECOMMUNICATION SYSTEMS ARE
DEPENDENT ON ELECTRICAL POWER FOR THEIR 24 X 7 X 365 OPERATION
AND FUNCTION. EQUIPMENT SHALL BE CONNECTED TO THE CRITICAL
BRANCH OF THE ESSENTIAL ELECTRICAL SYSTEM. EQUIPMENT (OTHER THAN
HVAC) SHALL BE BACKED BY AN UPS WITH RUNNING TIME AS REQUIRED IN
PSDM REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL POWER DESIGN.
2. ROOMS CONTAINING IT EQUIPMENT SHALL HAVE STATIC-DISSIPATIVE
FLOORING. REFER TO ARCHITECTURAL DRAWINGS.
3. CMLPS SHALL BE DIRECTLY CONNECTED TO THE FACILITY'S EXTERNAL FLPS.
FLPS CONTRACTOR SHALL PROVIDE A WRITTEN APPROVAL FOR THE
CONNECTION OF THE COMMUNICATIONS CLPS TO THE FLPS AND MAKE THAT
AUTHORIZATION A PART OF THE SYSTEM'S FINAL APPROVED INSTALLATION
DRAWINGS AND SPECIFICATIONS.
4. THE TELECOMMUNICATIONS CONTRACTOR IS NOT ALLOWED TO MAKE
PENETRATIONS OR MODIFICATIONS TO THE ROOF.
5. VACO OI&T SERVICE SHALL PROVIDE ACTIVE WI-FI EQUIPMENT TO THE
PROJECT SUBCONTRACTOR FOR INSTALLATION. APPROVED WI-FI BASED
ADD-ON SYSTEMS ARE THE RESPONSIBILITY OF THE FACILITY OI&T SERVICE.
6. CONTRACTOR SHALL PROVIDE SUFFICIENT CABLE AND INSTALL OUTLETS
WITH ABILITY TO RELOCATE WIRELESS ACCESS POINTS BASED ON A
PHYSICAL SITE SURVEY AFTER OCCUPATION OF THE FACILITY.
7. CONTRACTOR SHALL PROVIDE FLUSH-MOUNTED SINGLE-GANG OUTLET
BOXES WITH TWO-PORT BASE PLATES AND APPLICABLE WALL DEVICE
FACEPLATES AT DRYWALL LOCATIONS (CABLE TO BE INSTALLED BEHIND
DRYWALL) AND PROVIDE SURFACE-MOUNTED SINGLE-GANG OUTLET BOXES
WITH TWO-PORT BASE PLATES AND APPLICABLE WALL DEVICE FACEPLATES
AT SOLID WALL LOCATIONS (CABLE TO BE INSTALLED IN PLASTIC WALL MOLD
EQUIPPED WITH PROTECTIVE INSULATOR OR SLEEVE)
8. DATA ROOM/CLOSET SHALL HAVE A DRY POWDER EXTINGUISHER, SUITABLE
FOR ELECTRICAL FIRES, PROVIDED AND INSTALLED WITHIN THE ROOM
9. TELECOMMUNICATIONS ROOMS SHALL BE LOCATED ABOVE THE BASE FLOOD
ELEVATION; SHALL NOT BE LOCATED IN PATIENT CARE AREAS; AND SHALL
NOT BE LOCATED BENEATH TOILETS, SHOWERS, LABORATORIES, KITCHENS,
SINKS, OPEN COURTYARDS, PLANTERS, ROOF DRAIN LEADERS, OR OTHER
AREAS WHERE WATER SERVICE IS PROVIDED
10. ANY PIPE OR DUCT SYSTEM FOREIGN TO THE TELECOMMUNICATIONS
INSTALLATION SHALL NOT ENTER OR PASS THROUGH A
TELECOMMUNICATIONS ROOM.
11.CABLE TYPE: 4-PAIR CAT6, IEEE 802.3 100BASET UNSHIELDED TWISTED
PAIR(UTP) LEVEL 5E/6, 24 AWG PLENUM RATED.
12. TERMINATE PAIRS ACCORDING TO THE T568B WIRING SCHEME. PIN ALL 8
CONDUCTORS. MAXIMUM LINK LENGTH - 90 METERS, CHANNEL LENGTH - 100
METERS
13. TWO METER LOOP OF CABLE SHALL BE LEFT WITHIN EACH COMMUNICATIONS
ROOM/ENCLOSURE FOR FUTURE MODIFICATIONS.SLACK SHALL BE COILED
AND SUPPORTED. 0.5-METER LOOP OF CABLE SHALL BE LEFT IN THE
TRUNKING ON THE APPROACH TO EACH NETWORK OUTLET
14.CABLE BEND RADII SHALL BE NO LESS THAN EIGHT TIMES THE CABLE
DIAMETER OR AS SPECIFIED BY THE CABLE MANUFACTURER; WHICHEVER IS
THE GREATER.
15.ELECTRICAL CABLES SHALL NOT RUN PARALLEL WITH UTP CABLES.
ELECTRICAL MOTORS AND TRANSFORMER SHALL NOT BE INSTALLED IN
PROXIMITY TO UTP CABLES.
SECURITY
1. CONTRACTOR SHALL DIRECT ATTACH ALL HORIZONTAL CABLING AND
TERMINATE WITH A FIELD INSTALLABLE PLUG AND THEN CONNECT DIRECTLY
TO IP CAMERAS, OR OTHER SECURITY EQUIPMENT AVOIDING A POINT OF
FAILURE.
2. MOST PATCH CORDS ARE NOT CONSTRUCTED WITH PLENUM-RATED. CABLE
SHALL NOT BE INSTALLED IN A PLENUM SPACE.
3. CONTRACTOR TO PROVIDE DATA CIRCUIT PROTECTION MODULES THAT
PROVIDE PROTECTION AGAINST OVERVOLTAGE AND OVERCURRENT
CONDITIONS AT ALL CABLES THAT ENTER THE FACILITY FROM THE EXTERIOR
INCLUDING EQUIPMENT ATTACHED TO THE EXTERIOR WALL OF THE BUILDING
(E.G., IP SECURITY CAMERAS). APPROVE ONLY DEVICES RATED FOR POE AT
EQUIPMENT USING POE.
4. CONTRACTOR TO COORDINATE CAMERA MANUFACTURING REQUIREMENTS
FOR INSTALLATION AND CABLING. SOME IP CAMERA MANUFACTURERS
REQUIRE SHIELDED CABLE TO MAINTAIN THE WARRANTY WHERE THE
CAMERA IS INSTALLED OUTDOORS OR WHERE THE NETWORK CABLE IS
ROUTED OUTDOORS.
5. ALL LOCKS SHALL BE FIELD SELECTABLE FAIL SAFE/FAIL SECURE PER VA
PHYSICAL SECURITY APPENDIX A SECURITY DOOR OPENING MATRIX. IN FAIL
SECURE THE LOCK WILL REMAIN SECURE WHEN IN FAIL MODE THOUGH IT
SHALL ALWAYS PERMIT EMERGENCY EGRESS FUNCTIONS OF THE LOCK.
CONVENTIONAL KEY AND LOCK, SHALL BE PROVIDED TO ALLOW ACCESS
FROM THE UNSECURED SIDE. MAGNETIC LOCKS SHALL NOT FAIL SECURE.
6. CARD ACCESS SECURITY SYSTEMS SHALL INCLUDE A MECHANICAL KEY
RELEASE, PER VA FIRE PROTECTION DESIGN MANUAL 2015.
7. PROVIDE PACS SYSTEM COMPATIBLE WITH EXISTING HOSPITAL PACS
SYSTEM. EXTEND EXISTING SYSTEM AS REQUIRED TO ACCOMMODATE NEW
DEVICES SHOWN ON PLANS.
INSTALLATION RELATED PROCEDURES
1. ALL WORK PERFORMED ON HUNTER HOLMS MCGUIRE VA MEDICAL CENTER
MUST BE CARRIED OUT BY CONTRACTORS HOLDING CURRENT
MANUFACTURER (HELLERMANN-TYTON/HITACHI) COPPER & FIBER
STRUCTURED CONNECTIVITY SOLUTIONS H2MAX CERTIFICATION.
2. ALL PERSONNEL ATTEND "A MANDATORY SAFETY COURSE HELD BY VAMC
SAFETY OFFICE".
3. ALL COMMUNICATION CABLING SHALL BE FULLY DOCUMENTED PRIOR TO
ANY WORK COMMENCING.
4. ALL COMMUNICATION CABLING IS APPROVED BY THE NETWORK OR
TELECOMMUNICATION ENGINEER PRIOR TO ANY WORK COMMENCING.
5. ALL COMMUNICATION CABLING ARE "AS BUILT" DOCUMENTED ON PRACTICAL
COMPLETION. A COPY OF THE LOGICAL DIAGRAM, PHYSICAL CABLING
LAYOUT AND TEST RESULTS ARE PROVIDED TO THE NETWORK OR
TELECOMMUNICATION ENGINEER
6. COMMUNICATIONS CABLING SHALL NOT BE CONNECTED TO ANY EXISTING
DEVICES BELONGING TO HUNTER HOLMS MCGUIRE VA MEDICAL CENTER.
7. UNDER NO CIRCUMSTANCES SHALL ANY PENETRATION OF FLOORS, WALLS
OR CEILINGS; TO INCLUDE ACCESSING EXISTING CABLE PATHS THROUGH
FLOORS, WALLS OR CEILINGS BE CONDUCTED WITHOUT THE PRIOR
CONSENT OF MCGUIRE VA MEDICAL CENTER ENGINEERING SAFETY DEPT.
8. DURING INSTALLATION OF CABLING THE BUILDING/SAFETY ENGINEER IS TO
BE ADVISED PRIOR TO ENCLOSURE OF ANY CABLING IN NON-ACCESSIBLE
AREAS. WALL, CEILING OR FLOOR PENETRATIONS; A MINIMUM OF 24-HOUR'S
NOTICE SHALL BE GIVEN TO THE BUILDING /SAFETY ENGINEER PRIOR TO
WORK COMMENCING AND UPON COMPLETION.
GENERAL NOTES
TELEPHONE/DATA OUTLET WITH 4 PORT
CONFIGURATION FACEPLATE - CEILING MOUNTED.
CCTV FIXED DOME IP CAMERAS
3/4" TO BIOMED 3E-1101
RX
PUSH BUTTON TO RELEASE DOOR.
3/4"C TO CONTROLLED PACS DOOR
RLJ
J-BOX ABOVE CEILING FOR MULTIPLE RELAYS FOR
SPECIAL DOOR OPERATION
3 1
TELEPHONE/DATA OUTLET WITH 4 PORT
CONFIGURATION FACEPLATE. ALL FOUR ACTIVE.
MOUNTED AT 18" AFF UNLESS OTHERWISE
SPECIFIED.
SLACK LOOP, ABOVE CEILING, FOR FUTURE DATA
OUTLET. SEE TELECOMM DETAILS.
DC
ELECTRIC LOCKSET. SOLENOID BUILT IN TO LOCK
OR UNLOCK BY SPECIAL EQUIPMENT USED ON
DOOR
EL
DOOR OPERATOR TRIGGERED WITH SENSOR OR AS
SHOWN ON DRAWINGS
DO
ELECTRIC STRIKE (PACS SYSTEM COMPONENT)
ELECTRIC TRANSFER HINGE (PACS SYSTEM
COMPONENT)
MAGNETIC LOCK (PACS SYSTEM COMPONENT)
ES
EH
ML
SL
J
CR
J
CAM
J
SLACK LOOP, ABOVE CEILING, FOR FUTURE CARD
READER. SEE TELECOMM DETAILS.
SLACK LOOP, ABOVE CEILING, FOR FUTURE
CAMERA. SEE TELECOMM DETAILS.
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
TELECOMMUNICATION ABBREVIATIONS,
NOTES
SYMBOLS, & GENERAL
TN001
DKSGGR/DKS
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
P V A D
U
V A
R i c h m o n d
L a b D r a w i n g s T e l e c o m
V A D
U
R I C H
M O
N D
L A B
T e l e c o m
P l a n
T N d w g
P M
A R C H f u l l b l e e d
E x
I n c h e s
TWO EXISTING RACKS TO REMAIN
F R
O N
T
R E
A R
F R
O N
T
R E
A R
EXISTING PLYWOOD BOARD AND
MOUNTED EQUIPMENT TO REMAIN
GENERAL NOTES
1. SEE SHEET TN001 FOR GENERAL NOTES, ABBREVIATIONS AND SYMBOLS.
KEY NOTES
1. USE SPARE SPACE ON EXISTING FIBER OPTIC PATCH PANEL AND PROVIDE 12
STRAND SM FIBER TO IT CLOSET 3F-05 ON THIRD FLOOR FOR NEW LAB.
2. PROVIDE 3/4" FIRE RATED PLYWOOD IN THIS WALL NEXT TO THE EXISTING
BOARD AS SHOWN
3. PROVIDE A 110 BLOCK TELEPHONE WIRING BLOCK FOR A MINIMUM AMOUNT OF
TELEPHONE LINES. A 50 PAIR BLOCK BASE WITH 4-PAIR C-CLIPS.
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i e a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
BUILDING1: 1ST FLOOR
ROOM: 1B-216A
EXISTING FIBER CABINET. NEW FIBER
TO RUN TO NEW IT ROOM 3F105
BUILDING1: 1ST FLOOR
ROOM: 1B-216A
LOCATION OF NEW TWISTED PAIR FOR PHONE
CONNECTION (LOOKING PLAN EAST)
1ST FLOOR
TELECOMMUNICATION PLAN
TN111
DKSGGR/DKS
SCALE:
TN111
1ST FLOOR TELECOMMUNICATIONS PLAN
1/8" = 1'-0"
SCALE:
TN111
1ST FLOOR TELECOMMUNICATIONS PLAN - EXISTING IT ROOM PICS
1/8" = 1'-0"
PLAN
NORTH
TN
DN
DN
NPQRSTUVW
163 SF
STAIR
3F-ST2
Wn
17284 SF
INTERSTITIAL
3F-INT
F O F O F O F O F O
SCALE:
TN121
INTERSTITIAL TELECOMMUNICATION PLAN
1/8" = 1'-0"
GENERAL NOTES
1. SEE SHEET TN001 FOR GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
KEY NOTES
1. RUN (1) 2" CONDUIT WITH PULL STRINGS FROM BASEMENT AND FIRST
FLOOR AND STUB UP AT NEW OIT ROOM. ENCLOSED WIREWAYS ARE
ACCEPTABLE IN INTERSTITIAL SPACE ONLY.
2. CONDUIT RUN IN INTERSTITIAL SPACE SHALL TERMINATE AT THE TOP OR
BOTTOM OF THE BACKBOARD BUT SHALL NOT COVER ANY PORTION OF THE
BACKBOARD PER VA TELECOM DESIGN GUIDE.
3. NEW IT ROOM 3F-104 LOCATED ABOVE ON 3RD LEVEL.
4. EXISTING MICU OIT ROOM LOCATED ABOVE ON 3RD LEVEL.
5. GC TO FOLLOW SAME ROUTE AS FOLLOWED FOR THE PENETRATION FROM
THE BASEMENT TO THE THIRD FLOOR MICU'S IT CLOSET.
6. ENCLOSED WIREWAYS ARE ACCEPTABLE IN INTERSTITIAL SPACE ONLY.
15 6
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
KEYPLAN
LAB EXPANSION
PLAN
NORTH
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
TN
N
2ND FLOOR INTERSTITIAL
TELECOMMUNICATION PLAN
TN121
DKSGGR/DKS
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
KEYPLAN
LAB EXPANSION
PLAN
NORTH
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
TN
N
8'0 4' 16'
SCALE:1/8"=1'-0"
P V A D
U
V A
R i c h m o n d
L a b D r a w i n g s T e l e c o m
V A D
U
R I C H
M O
B
T e l e c a n
T N d w g
P M
A R l l b l e e d
E x
I n c h e s
GENERAL NOTES
1. SEE SHEET TN001 FOR GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
2. SEE SHEET TN501 AND TN502 FOR TELECOM DETAILS.
3. ALL CAT6 COPPER BALANCED TWISTED PAIR CABLING, INSTALLED WITHIN THE
VA MEDICAL FACILITIES/BUILDINGS SHALL BE UL LISTED AND MARKED TYPE
CMP (PLENUM RATED).
4. ROUTE ALL TELECOMMUNICATIONS CABLE CONCEALED, INCLUDING WHERE
CONNECTIONS ARE SHOWN ON PLANS.
5. PROVIDE HOMERUNS FROM IT CLOSET TO ALL EQUIPMENT SHOWN, UNLESS
NOTED OTHERWISE.
6. REFERENCE AI601 FOR ADDITIONAL DOOR CONTROL REQUIREMENTS.
7. LOCATE PRE-FURNITURE INFRASTRUCTURE AS REQUIRED TO FEED
FURNITURE SHOWN ON TN131 AFTER FURNITURE IS INSTALLED.
KEY NOTES
1. NOT USED.
2. PROVIDE ELECTRICAL ROUGH IN FOR FUTURE SECURITY CAMERA.
3. THE EXISTING PA SYSTEM WILL BE RETAINED. EXTEND/TIE IN TO EXISTING PA
SYSTEM.
4. CABLING SHALL BE INSTALLED ABOVE SUSPENDED CEILINGS USING WIRE
BASKET CABLE TRAYS PER TASTS DM CHAPTER 2. PROVIDE 12"X2" BASKET
TRAY UNLESS OTHERWISE INDICATED.
5. PROVIDE UNIVERSAL ARCHITECTURAL WALL ARM TV MOUNT FOR 42" TV OR
LARGER BLACK IN COLOR WITH MEDIA PLAYER CONTROL DEVICE AND WIRE
MANAGEMENT. B.O.D. PEERLESS SA752PU WITH DSX-750 OR APPROVED EQUAL.
6. PROVIDE 24VDC OR 24VAC, 3W MAX POWER FOR TUG. TUG RELAY WILL MOUNT
ABOVE THE CEILING NEXT TO THE DOOR CONTROLLER BOX. DRILL 0.5 INCH
HOLE IN DOOR CONTROLLER BOX FOR TUG CONNECTION BY AETHON.
WIRELESS RELAY (433MHZ) AND CABLING WILL BE PROVIDED BY AETHON FOR
THE TUG. AETHON ROBOT TUGS SHALL BE ABLE TO COME FROM THE
CORRIDOR INTO THE LAB ACCESSIONING AREA (3F-106A) AND BACK OUT.
7. PROVIDE ETHERNET ONLY DATA JACK FOR SWISSLOG HEALTHCARE
SOLUTIONS PNEUMATIC TUBE SYSTEM (PTS) STATION CONTROL. SEE DETAILS
SHEET.
8. PROVIDE CONTROLLER AT THE RECEPTIONIST'S PASS-THROUGH WINDOW TO
UNLOCK AND OPEN THE DOOR. TIE THE CARD READER TO THIS CONTROLLER.
CARD READER MUST ALSO UNLOCK AND OPEN THE DOOR.
9. PRIVATE WIRELESS ACCESS POINT, CEILING MOUNTED.
10. PUBLIC WIRELESS ACCESS POINT, CEILING MOUNTED.
11. CONNECT TO FIRE ALARM ADDRESSABLE RELAY OUTPUT MODULE TO BE
MOUNTED ABOVE HOLD OPEN DOOR.
12. PROVIDE QUALIFIED SYSTEMS TO FIRESTOP THROUGH PENETRATIONS IN
FIRE-RATED WALLS FOR CABLE, CONDUITS, INNER-DUCTS AND CABLE TRAYS.
INSIDE ALL CONDUITS, THE FIRESTOP SYSTEM SHALL CONSIST OF A
DIELECTRIC, WATER-RESISTANT, NON-HARDENING, PERMANENTLY
PLIABLE/RE-ENTERABLE PUTTY ALONG WITH APPROPRIATE DAMMING OR
BACKER MATERIALS.
13. PROVIDE QUANTITY OF DATA OUTLETS WITHIN RACEWAY AS SHOWN. PROVIDE
TWO DROPS FOR EACH DATA OUTLET. SEE POWER PLANS FOR RECEPTACLE
QUANTITY. RACEWAY CONTAINING TELECOM CABLES SHALL BE DUAL CHANNEL
RACEWAY SYSTEMS TO SEPARATE POWER AND NETWORK CABLING.
14. PROVIDE POWER/DATA POLE TO FEED WIREMOLD ABOVE DESKS. REFER TO
GENERAL DRAWINGS FOR BASE BID AND BID OPTIONS.
15. PROVIDE POWER/DATA POLE TO FEED CHEMISTRY EQUIPMENT. PROVIDE A
TOTAL OF 4 DROPS FOR EACH OF THE DATA OUTLETS.
16. COORDINATE WITH CONSTRUCTION PHASING TO PLACE J-BOX AND RACEWAY
FOR THE CARD READER IN PLACE BEFORE THE CINDER BLOCK WALL IS BUILT.
CAR READER WILL BE ON THE OUTSIDE OF THE DOOR (STAIR SIDE) AND PANIC
BAR ON THE INSIDE.
17. PROVIDE 2-PORT DATA OUTLET FOR PRINTER STATION.
18. FIELD COORDINATE WITH FURNITURE SYSTEM; PROVIDE DATA OUTLETS UNDER
COUNTER. PROVIDE ROUTE FOR PERIPHERAL CONNECTIONS, SUCH AS
MONITOR, KEYBOARD, AND MOUSE CONNECTIONS BEHIND COUNTER. DO NOT
MAKE OPENINGS IN COUNTER SURFACE.
19. EXTEND 1" CONDUIT WITH COMMUNICATIONS WIRING FROM OUTLET TO ABOVE
FINISHED CEILING TO CABLE TRAY. WHEN CABLING LEAVES CABLE TRAY GC
SHALL TRANSITION TO CONDUIT. GC SHALL MINIMIZE THE USE OF CABLE
HOOKS. CABLE HOOKS SHALL BE USED MAINLY TO SUPPORT SLACK CABLING.
20. DEDUCTIVE BID ALTERNATE 2: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE WITHIN IDENTIFIED BOUNDARY AS SHOWN. CONSTRUCT
TELECOMMUNICATIONS INFRASTRUCTURE IN THIS BOUNDARY PRIOR TO
FURNITURE INSTALLATION
21. DEDUCTIVE BID ALTERNATE 4: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE WITHIN IDENTIFIED BOUNDARY PER DRAWING TN131.2
22. DEDUCTIVE BID ALTERNATE 5: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE WITHIN IDENTIFIED BOUNDARY PER DRAWING TN131.2
23. DEDUCTIVE BID ALTERNATE 6: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE WITHIN IDENTIFIED BOUNDARY PER DRAWING TN131.2
24. CONSTRUCT TELECOMMUNICATIONS INFRASTRUCTURE IN THIS BOUNDARY TO
THE FINAL CONFIGURATION SHOWN; SEE TN131.2 FOR PRE-FURNITURE
INSTALLATIONS.
25. SUBSTITUTE VOICE TELECOM JACK WITH DEDICATED DATA CONNECTION
BETWEEN SIEMENS CHEMISTRY LINE, AND CONTROLLING PC. CONFIGURE
DEDICATED CONNECTION IN ACCORDANCE WITH SYSTEM MANUFACTURER
INSTRUCTIONS.
P
F
PF
R E
F
R E
F
P F
P F
P
F
PF
NPQRSTUVW
437 SF
CORRIDOR
C3F-1
1181 SF
CORRIDOR
C3F-2
188 SF
BIOMED
3F-101
405 SF
ANCILLARY TESTING
3F-103
117 SF
DRUG TESTING
3F-105
81 SF
IT CLOSET
3F-104
106 SF
ELEC CLOS
3F-102
387 SF
ACCESSIONING
3F-106a
467 SF
FEE BASIS
3F-106b
1015 SF
HEMATOLOGY
3F-106e
1529 SF
CHEMISTRY
3F-106f
231 SF
REFRIGERATEDSTORAGE
3F-126
544 SF
BLOOD BANK
3F-106c
495 SF
CYTOLOGY
3F-106h
1179 SF
OPEN OFFICE
3F-106j
273 SF
ARCHIVE
3F-124
372 SF
CLEAN SUPPLY
3F-131
147 SF
BSL-3 LAB
3F-129
70 SF
STAFF TOILET
3F-108
65 SF
DRUG TESTING TOILET
3F-105a
511 SF
IMMUNOLOGY
3F-107
301 SF
MEN'S TOILET
3F-109
304 SF
WOMEN'S TOILET
3F-111
52 SF
JANITOR
3F-110
121 SF
EQUIPMENT ROOM
3F-130
93 SF
GAS TANK ROOM
3F-127
378 SF
BREAK ROOM
3F-112
112 SF
CORRIDOR
C3F-3
109 SF
OFFICE #1
3F-114
115 SF
OFFICE #2
3F-115
100 SF
OFFICE #3
3F-116
113 SF
OFFICE #4
3F-117
107 SF
OFFICE #5
3F-118
228 SF
ADMINISTRATION
3F-120
132 SF
DIRECTOR'S OFFICE
3F-121
94 SF
CMT OFFICE
3F-122
87 SF
OFFICE #6
3F-123
345 SF
ADPAC/RESIDENTS
3F-119
77 SF
FLAMMABLE STORAGE
3F-125
125 SF
ANTE ROOM
3F-128
1560 SF
HISTOLOGY
3F-106g
164 SF
STAIR
3F-S2
W4
129 128
C2
115 117
118114
A
B
C
S
A
C
A
C1
Wn
222 SF
CONF ROOM
3F-113
B
UC
W W
S S
S
S
S
DO
RX
DO
D O
RX
CR
W
J
RX
CRJ
CRJ
RX RX
RLJ
CRJ
C R
J
C R
J CR J
CR
J
C R
J
RX
CRJ CRJ
CRJ
WAP
WAP
WAP
WAP
WAP
CR4
CR 3
WAP
WAP
CR
CR
WAP
WAP
WAPWAP WAPWAP
WAP WAP
WAP
WAP
WAP
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATAPWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
UC
DATA
13 13
PWR
DATA
CO2 MONITOR
1 3
1 3 1 3
1 3
13 13 13
13 13 13 13 13 13
131313
13 13
13 13
13 13 13
131313
13 13
131313
1 3
1 3
1 3 1 3
1 3
1 3 1 3
1 3
SCALE:
TN131.1
POST FURNITURE CONSTRUCTION
3RD FLOOR TELECOMMUNICATION PLAN
1/8" = 1'-0"
DEDUCTIVE BID ALTERNATE # 2
CAMERAS, PACS
CAMJCAMJ CAMJ
CR
CR
13 13
1 31 3 1 3
1 3
11 11
11 11
13 13
1 3
1 3 x3 6 D
RO
PSx4
8 D
RO
PS
UC
x9 6 D
RO
PS
x132 DROPSx216 DROPS x3 6 D
RO
PS
x312 DROPS x9 6 D
RO
PS
x6 4 D
RO
PS
x1
D
RO
PS
x432 DROPS
12INx6IN 12INx4IN 12INx4IN
12INx6IN
11 11
11 11
UC
11 11 11 11 11
11 1111
11 11 11 11
11 11
UC
PWR
DATA
EL
E H
ES ES
ES
ES
D O
DC
DC
DCDC
TYP
M L
M L
DC DC
DC
RX
ML
ML
CRJ
CRJ
CRJ
CR
J
CRJ
D C
D C
CRJ
PWR
DATA
SL
CRJ
2TYP2TYP
SLJ
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SLJ
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
12 8
15 15
TV
T V
RX
CR
ES DC
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
KEYPLAN
LAB EXPANSION
PLAN
NORTH
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
TN
N
3RD FLOOR
DEDUCTIVE ALTERNATE #2
TELECOMMUNICATION PLAN
TN131.1
DKSGGR/DKS
8'0 4' 16'
SCALE:1/8"=1'-0"
P V A D
U
V A
R i c h m o n d
L a b D r a w i n g s T e l e c o m
V A D
U
R I C H
M O
B
T e l e c a n
T N d w g
P M
A R l l b l e e d
E x
I n c h e s
1. SEE SHEET TN001 FOR GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
2. SEE SHEET TN501 AND TN502 FOR TELECOM DETAILS.
3. ALL CAT6 COPPER BALANCED TWISTED PAIR CABLING, INSTALLED WITHIN THE
VA MEDICAL FACILITIES/BUILDINGS SHALL BE UL LISTED AND MARKED TYPE
CMP (PLENUM RATED).
4. PROVIDE HOMERUNS FROM IT CLOSET TO ALL EQUIPMENT SHOWN, UNLESS
NOTED OTHERWISE.
5. REFERENCE AI601 FOR ADDITIONAL DOOR CONTROL REQUIREMENTS.
KEY NOTES
1. DOOR AND FRAME TO BE PREPPED FOR PACS. ELECTRICAL ROUGH IN TO BE
PROVIDED. SEE DOOR SCHEDULE ON ARCHITECTURAL DRAWINGS.
2. PROVIDE ELECTRICAL ROUGH IN FOR FUTURE SECURITY CAMERA
3. PROVIDE 20' SLACK CAT6 CABLING ABOVE SUSPENDED CEILING FOR FUTURE
WIREMOLD INSTALLATION. TIE SLACK CABLE WITH HOOK.
4. THE EXISTING PA SYSTEM WILL BE RETAINED. EXTEND/TIE IN TO EXISTING PA
SYSTEM.
5. CABLING SHALL BE INSTALLED ABOVE SUSPENDED CEILING USING WIRE
BASKET CABLE TRAYS PER DM CHAPTER 2. PROVIDE 12"X2" BASKET TRAY
UNLESS OTHERWISE INDICATED.
6. PRIVATE WIRELESS ACCESS POINT. CEILING MOUNTED.
7. PUBLIC WIRELESS ACCESS POINT. CEILING MOUNTED.
8. PROVIDE CONTROLLER AT THE RECEPTIONIST'S PASS-THROUGH WINDOW TO
UNLOCK AND OPEN THE DOOR. TIE THE CARD READER TO THIS CONTROLLER.
CARD READER MUST ALSO UNLOCK AND OPEN THE DOOR.
9. CONNECT TO FIRE ALARM ADDRESSABLE RELAY OUTPUT MODULE TO BE
MOUNTED ABOVE HOLD OPEN DOOR.
10. PROVIDE QUALIFIED SYSTEMS TO FIRESTOP THROUGH PENETRATIONS IN
FIRE-RATED WALLS FOR CABLES, CONDUITS, INNER-DUCTS AND CABLE TRAYS.
INSIDE ALL CONDUITS, THE FIRESTOP SYSTEM MUST CONSIST OF THE
DIELECTRIC, WATER-RESISTANT, NON-HARDENING, PERMANENTLY
PLIABLE/RE-ENTERABLE PUTTY ALONG WITH APPROPRIATE DAMMING OR
BACKER MATERIALS.
11. EXTEND 1" CONDUIT WITH COMMUNICATIONS WIRING FROM OUTLET TO ABOVE
FINISHED CEILING TO CABLE TRAY. WHEN CABLING LEAVES CABLE TRAY GC
MUST TRANSITION TO CONDUIT. GC MUST MINIMIZE THE USE OF CABLE HOOKS.
CABLE HOOK WILL BE USED MAINLY TO SUPPORT SLACK CABLING.
12. DEDUCTIVE BID ALTERNATE 4: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE IN THIS BOUNDARY AS SHOWN.
13. DEDUCTIVE BID ALTERNATE 5: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE IN THIS BOUNDARY AS SHOWN.
14. DEDUCTIVE BID ALTERNATE 6: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE IN THIS BOUNDARY AS SHOWN.
15. CONSTRUCT TELECOMMUNICATIONS INFRASTRUCTURE IN THIS BOUNDARY
PRIOR TO FURNITURE INSTALLATION
UC
CORRIDOR
C3F-1
81 SF
IT CLOSET
3F-104
105 SF
ELEC CLOS
3F-102
387 SF
ACCESSIONING
3F-106a
467 SF
FEE BASIS
3F-106b
1908 SF
MICROBIOLOGY
3F-106d
1019 SF
HEMATOLOGY
3F-106e
1534 SF
CHEMISTRY
3F-106f
231 SF
REFRIGERATEDSTORAGE
3F-126
544 SF
BLOOD BANK
3F-106c
496 SF
CYTOLOGY
3F-106h
1179 SF
OPEN OFFICE
3F-106j
273 SF
ARCHIVE
3F-124
372 SF
CLEAN SUPPLY
3F-131
147 SF
BSL-3 LAB
3F-129
70 SF
STAFF TOILET
3F-108
121 SF
EQUIPMENT ROOM
3F-130
77 SF
FLAMMABLE STORAGE
3F-125
125 SF
ANTE ROOM
3F-128
1583 SF
HISTOLOGY
3F-106g
93 SF
GAS TANK ROOM
3F-127
164 SF
STAIR
3F-S2
NPQRSTUVW
Wn
W W
S S
S
S
S
DO
RX
DO
D O
RX
CR
W
J
CRJ
CRJ
RX RX
RLJ
CRJ
C R
J
C R
J CR J
CR
J
C R
J
RX
CRJ CRJ
CRJ
WAP
WAP
WAP
WAP
WAP
CR4
CR 3
WAP
WAP
CR
CR
WAP
WAP
WAPWAP WAPWAP
WAP WAP
WAP
WAP
WAP
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATAPWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
CO2 MONITOR
1 3
13 13 13 13 13 13 13 13 13
131313
13 13
131313
1 3
1 3
1 3
SCALE:
TN131.2
PRE FURNITURE CONSTRUCTION
3RD FLOOR TELECOMMUNICATION PLAN
1/8" = 1'-0"
DEDUCTIVE BID ALTERNATE # 6
NORTH INTERIOR BATHROOMS 3F109, 3F110, 3F111, 3F108 AND CORRIDOR C3F-2
DEDUCTIVE BID ALTERNATE # 5
NORTH INTERIOR ROOMS C3F3, 3F114, 3F115, 3F116, 3F117, 3F118, 3F120, 3F121, 3F122, 3F119 AND
3F123
DEDUCTIVE BID ALTERNATE # 4
NORTH INTERIOR ROOMS 3F101, 3F103, 3F105, 3F105a, 3F107, 3F112 AND 3F113
CAMJCAMJ CAMJ
CR
DEDUCTIVE BID ALTERNATE # 2
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
13SL
J
SL
J
SL
J
1 3
SL
J
SL
J
SL
J
SL
J
SL
J x3 6 D
RO
PSx4
8 D
RO
PS
UC
x9 6 D
RO
PS
x132 DROPSx216 DROPS x3 6 D
RO
PS
x312 DROPS x9 6 D
RO
PS
x6 4 D
RO
PS
x1
D
RO
PS
x432 DROPS
12INx6IN 12INx4IN 12INx4IN
12INx6IN
11 11
11 11
PWR
DATA
EL
E H
ES ES
ES
D O
DC
DCDC
TYP
M L
M L
ML
ML
CRJ
CRJ
CRJ
CR
J
CRJCRJ
CRJ
CR
J SL
J SL
J
PWR
DATA
SL
J
SL
J
SL
CRJ
1 TYP
2TYP2TYP
SLJ
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SLJ
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
CRJ
7 6
SL
J
SL
J
SL
J
4 54
6 7
1 TYP 1 TYP
1 TYP 1 TYP 1 TYP
1 TYP1TYP
1 TYP
TV
T V
13121412
RX
CR
ES DC
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
KEYPLAN
LAB EXPANSION
PLAN
NORTH
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
TN
N
3RD FLOOR
BID ALTERNATES #2, 4, 5, 6
TELECOMMUNICATION PLAN
TN131.2
DKSGGR/DKS
8'0 4' 16'
SCALE:1/8"=1'-0"
P V A D
U
V A
R i c h m o n d
L a b D r a w i n g s T e l e c o m
V A D
U
R I C H
M O
B
T e l e c a n
T N d w g
P M
A R l l b l e e d
E x
I n c h e s
F
PF
R E
F
R E
F
P F
P F
P
F
PF
NPQRSTUVW
437 SF
CORRIDOR
C3F-1
1181 SF
CORRIDOR
C3F-2
188 SF
BIOMED
3F-101
405 SF
ANCILLARY TESTING
3F-103
117 SF
DRUG TESTING
3F-105
81 SF
IT CLOSET
3F-104
106 SF
ELEC CLOS
3F-102
387 SF
ACCESSIONING
3F-106a
467 SF
FEE BASIS
3F-106b
1015 SF
HEMATOLOGY
3F-106e
1529 SF
CHEMISTRY
3F-106f
231 SF
REFRIGERATEDSTORAGE
3F-126
544 SF
BLOOD BANK
3F-106c
495 SF
CYTOLOGY
3F-106h
1179 SF
OPEN OFFICE
3F-106j
273 SF
ARCHIVE
3F-124
372 SF
CLEAN SUPPLY
3F-131
147 SF
BSL-3 LAB
3F-129
70 SF
STAFF TOILET
3F-108
65 SF
DRUG TESTING TOILET
3F-105a
511 SF
IMMUNOLOGY
3F-107
301 SF
MEN'S TOILET
3F-109
304 SF
WOMEN'S TOILET
3F-111
52 SF
JANITOR
3F-110
121 SF
EQUIPMENT ROOM
3F-130
93 SF
GAS TANK ROOM
3F-127
378 SF
BREAK ROOM
3F-112
112 SF
CORRIDOR
C3F-3
109 SF
OFFICE #1
3F-114
115 SF
OFFICE #2
3F-115
100 SF
OFFICE #3
3F-116
113 SF
OFFICE #4
3F-117
107 SF
OFFICE #5
3F-118
228 SF
ADMINISTRATION
3F-120
132 SF
DIRECTOR'S OFFICE
3F-121
94 SF
CMT OFFICE
3F-122
87 SF
OFFICE #6
3F-123
345 SF
ADPAC/RESIDENTS
3F-119
77 SF
FLAMMABLE STORAGE
3F-125
125 SF
ANTE ROOM
3F-128
1560 SF
HISTOLOGY
3F-106g
164 SF
STAIR
3F-S2
W4
129 128
C2
115 117
118114
A
B
C
S
A
C
A
C1
Wn
222 SF
CONF ROOM
3F-113
B
UC
A
A
W W
S S
S
S
S
3 3 3
TN431
DO
RX
DO
D O
RX
SCALE:
TN131
POST FURNITURE CONSTRUCTION
3RD FLOOR TELECOMMUNICATION PLAN
1/8" = 1'-0"
H O
O D
HOOD
CR
W
J
RX RX RX
RX RX
RLJ
D O
RX
D O
D O
RX
D O
RX
E S
R X
RX
R X
RX
RX
RX
RX RX
R X
WAP
WAP
WAP
WAP
WAP
15CR4
C R
CR 3
WAP
WAP
CR
CR
WAP
WAP
WAPWAP
WAP
WAP
WAP WAP
WAP
WAP
WAP
11 11
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
DATA
PWR
UC
DATA
13 13
PWR
DATA
CO2 MONITOR
1 3
1 3 1 3
1 3
13 13 13
13 13 13 13 13 13
131313
13 13
CR
13 13
C R 19
13 13
C R
CR
131313
1 3
1 3
1 3 1 3
1 3
1 3 1 3
1 3
CR
CR14 CR15 CR16
C R
22 CR
C R
CR
CR
CR
13 13
1 31 3 1 3
1 3
11 11
11 11
13 13
1 3
1 3 x3 6 D
RO
PSx4
8 D
RO
PS
SCALE:
TN131
TYPICAL TELECOM WIRING
1/8" = 1'-0"
UC
x9 6 D
RO
PS
x132 DROPSx216 DROPS x3 6 D
RO
PS
x312 DROPS x9 6 D
RO
PS
TN131
x6 4 D
RO
PS
x1
D
RO
PS
x432 DROPS
12INx6IN 12INx4IN 12INx4IN
12INx6IN
11 11
11 11
UC
11 11 11 11 11
11 1111
11 11 11 11
11 11
UC
PWR
DATA
EL
E H
CR
CR 6
CR12
ES ES
ES ES ES ES ESES
RX
ES ES
D O
R X
E S
E S
R X
E
S ES ES
DC DC DC DC DC
DCDC
DCDC
E S
D C
DC DC
D
CD
C
D
CD
C
ES DC
M L
M L
DC DC
M L
M L
DC DC
M L
M L
DC DC
DCDC
RX
01 02
ML
ML
DC ES
CR
RX
D C
D C
19 19
19 19
PWR
DATA
SL
SLJ
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SLJ
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
SL
J
TV
T V
20 21
20 23
20 21 20 22 20 22
20 22
RX
CR
ES DC
228 SF
ADMINISTRATION
3F-120
132 SF
DIRECTOR'S OFFICE
3F-121
94 SF
CMT OFFICE
3F-122
164 SF
STAIR
3F-S2
W4
CR
RX
RX RX
WAPWAP
13 13
13 13
CR
1 3
22 CR 23
CR13
1 3
13CAT6
CAT6
CAT6
CAT6
CAT6
x3 6 D
RO
PSEL ES
ES ES
DC
DC DC
RX
GENERAL NOTES
1. SEE SHEET TN001 FOR GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
2. SEE SHEET TN501 AND TN502 FOR TELECOM DETAILS.
3. ALL CAT6 COPPER BALANCED TWISTED PAIR CABLING, INSTALLED WITHIN THE
VA MEDICAL FACILITIES/BUILDINGS SHALL BE UL LISTED AND MARKED TYPE
CMP (PLENUM RATED)
4. ROUTE ALL TELECOMMUNICATIONS CABLE CONCEALED, INCLUDING WHERE
CONNECTIONS ARE SHOWN ON PLANS.
5. REFERENCE AI601 FOR ADDITIONAL DOOR CONTROL REQUIREMENTS.
6. PROVIDE HOMERUNS FROM IT CLOSET TO ALL EQUIPMENT SHOWN, UNLESS
NOTED OTHERWISE.
# KEY NOTES
1. CABLING SHALL BE INSTALLED ABOVE SUSPENDED CEILINGS USING WIRE
BASKET CABLE TRAYS PER TASTS DM CHAPTER 2. PROVIDE 12"X2" BASKET
TRAY UNLESS OTHERWISE INDICATED.
2. PROVIDE UNIVERSAL ARCHITECTURAL WALL ARM TV MOUNT FOR 42" TV OR
LARGER, BLACK IN COLOR WITH MEDIA PLAYER CONTROL DEVICE AND WIRE
MANAGEMENT. B.O.D. PEERLESS SA752PU WITH DSX-750 OR APPROVED EQUAL
3. BASE BID:PROVIDE IP MINI-DOME CAMERA AT FULL FRAME RATES (30 UOS
NTSC/25 IPS PAL). WIRE CAMS TO TELECOM RACK IN IT CLOSET. POE SWITCH
PROVIDED BY VA. GC TO PROVIDE PATCH PANEL, PATCH CORDS, AND CABLING
(CAT6) FROM CAMERAS TO GF/GI POE SWITCH.
DEDUCTIVE BID ALTERNATE #2: OMIT CAMERAS, PROVIDE ROUGH IN; SEE
TN131.1.
4. PROVIDE 24VDC OR 24VAC, 3W MAX POWER FOR TUG. TUG RELAY WILL MOUNT
ABOVE THE CEILING NEXT TO THE DOOR CONTROLLER BOX. DRILL 0.5 INCH
HOLE IN DOOR CONTROLLER BOX FOR TUG CONNECTION BY AETHON.
WIRELESS RELAY (433MHZ) AND CABLING WILL BE PROVIDED BY AETHON FOR
THE TUG. AETHON ROBOT TUGS SHALL BE ABLE TO COME FROM THE
CORRIDOR INTO THE LAB ACCESSIONING AREA (3F-106A) AND BACK OUT.
5. PROVIDE ETHERNET ONLY DATA JACK FOR SWISSLOG HEALTHCARE
SOLUTIONS PNEUMATIC TUBE SYSTEM (PTS) STATION CONTROL. INSTALL PER
MANUFACTURER INSTRUCTIONS AND REFERENCE 1/TN503 FOR ADDITIONAL
REQUIREMENTS.
6. THE EXISTING PA SYSTEM WILL BE RETAINED. EXTEND/TIE IN TO EXISTING PA
SYSTEM.
7. PROVIDE CONTROLLER AT THE RECEPTIONIST'S PASS-THROUGH WINDOW TO
UNLOCK AND OPEN THE DOOR. TIE THE CARD READER TO THIS CONTROLLER.
CARD READER MUST ALSO UNLOCK AND OPEN THE DOOR.
8. PRIVATE WIRELESS ACCESS POINT. CEILING MOUNTED.
9. CONNECT TO FIRE ALARM ADDRESSABLE RELAY OUTPUT MODULE TO BE
MOUNTED ABOVE HOLD OPEN DOOR
10. PROVIDE QUALIFIED SYSTEMS TO FIRESTOP THROUGH PENETRATIONS IN
FIRE-RATED WALLS FOR CABLES, CONDUITS, INNER-DUCTS AND CABLE TRAYS.
INSIDE ALL CONDUITS, THE FIRESTOP SYSTEM SHALL CONSIST OF A
DIELECTRIC, WATER-RESISTANT, NON-HARDENING, PERMANENTLY
PLIABLE/RE-ENTERABLE PUTTY ALONG WITH APPROPRIATE DAMMING OR
BACKER MATERIALS
11. PROVIDE QUANTITY OF DATA OUTLETS WITHIN RACEWAY AS SHOWN. PROVIDE
TWO DROPS FOR EACH DATA OUTLET. SEE POWER PLANS FOR RECEPTACLE
QUANTITY. RACEWAY CONTAINING TELECOMM CABLES SHALL BE DUAL
CHANNEL RACEWAY SYSTEMS TO SEPARATE POWER AND NETWORK CABLING.
12. PROVIDE POWER/DATA POLE TO FEED WIREMOLD ABOVE DESKS. REFER TO
GENERAL DRAWINGS FOR BASE BID AND BID OPTIONS.
13. PROVIDE POWER/DATA POLE TO FEED CHEMISTRY EQUIPMENT. PROVIDE A
TOTAL OF 4 DROPS FOR EACH OF THE DATA OUTLETS.
14. COORDINATE WITH CONSTRUCTION PHASING TO PLACE J-BOX AND RACEWAY
FOR THE CARD READER IN PLACE BEFORE THE CINDER BLOCK WALL IS BUILT.
CARD READER WILL BE ON THE OUTSIDE OF THE DOOR (STAIR SIDE) AND PANIC
BAR ON THE INSIDE.
15. PUBLIC WIRELESS ACCESS POINT, CEILING MOUNTED.
16. PROVIDE 2-PORT DATA OUTLET FOR PRINTER STATION
17. FIELD COORDINATE WITH FURNITURE SYSTEM; PROVIDE DATA OUTLETS UNDER
COUNTER. PROVIDE ROUTE FOR PERIPHERAL CONNECTIONS, SUCH AS
MONITOR, KEYBOARD, AND MOUSE CONNECTIONS BEHIND COUNTER. DO NOT
MAKE OPENINGS IN COUNTER SURFACE.
18. EXTEND 1" CONDUIT WITH COMMUNICATIONS WIRING FROM OUTLET TO ABOVE
FINISHED CEILING TO CABLE TRAY. WHEN CABLING LEAVES CABLE TRAY GC
SHALL TRANSITION TO CONDUIT. GC SHALL MINIMIZE THE USE OF CABLE
HOOKS. CABLE HOOKS SHALL BE USED MAINLY TO SUPPORT SLACK CABLING.
19. BASE BID: PROVIDE RACEWAYS AND ENCLOSURES WITH FACEPLATES FOR
PACS SYSTEMS AT DOORS IDENTIFIED BY THIS NOTE.
DEDUCTIVE BID ALTERNATE #2: SEE TN131.1 FOR ADDITIONAL REQUIREMENTS.
DEDUCTIVE BID ALTERNATE #6: SEE TN131.2 FOR ADDITIONAL REQUIREMENTS.
20. BASE BID: TELECOMMUNICATIONS INFRASTRUCTURE IN THIS BOUNDARY IS
INCLUDED UNDER THE BASE BID. PROVIDE TELECOMMUNICATIONS
INFRASTRUCTURE WITHIN IDENTIFIED BOUNDARY FOLLOWING FURNITURE
INSTALLATION. ENSURE WORK PERFORMED ON PRE-FURNITURE
CONSTRUCTION SHEETS IS LOCATED AND INSTALLED TO SUPPORT THIS FINAL
CONFIGURATION. FURNITURE IS GOVERNMENT-FURNISHED /
GOVERNMENT-INSTALLED.
21. DEDUCTIVE BID ALTERNATE 4: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE WITHIN IDENTIFIED BOUNDARY PER DRAWING TN131.2.
22. DEDUCTIVE BID ALTERNATE 5: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE WITHIN IDENTIFIED BOUNDARY PER DRAWING TN131.2.
23. DEDUCTIVE BID ALTERNATE 6: CONSTRUCT TELECOMMUNICATIONS
INFRASTRUCTURE WITHIN IDENTIFIED BOUNDARY PER DRAWING TN131.2.
24. CONSTRUCT TELECOMMUNICATIONS INFRASTRUCTURE IN THIS BOUNDARY TO
THE FINAL CONFIGURATION SHOWN. SEE TN131.2 FOR PRE-FURNITURE
INSTALLATIONS.
25. SUBSTITUTE VOICE TELECOM JACK WITH DEDICATED DATA CONNECTION
BETWEEN SIEMENS CHEMISTRY LINE, AND CONTROLLING PC. CONFIGURE
DEDICATED CONNECTION IN ACCORDANCE WITH SYSTEM MANUFACTURER
INSTRUCTIONS.
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
KEYPLAN
LAB EXPANSION
PLAN
NORTH
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
TN
N
3RD FLOOR
TELECOMMUNICATION PLAN
TN131
DKSGGR/DKS
8'0 4' 16'
SCALE:1/8"=1'-0"
P V A D
U
V A
R i c h m o n d
L a b D r a w i n g s T e l e c o m
V A D
U
R I C H
M O
B
T e l e c a n
T N d w g
P M
A R l l b l e e d
E x
I n c h e s
1. SEE SHEET TN001 FOR GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
2. SEE SHEET TN501 AND TN502 FOR TELECOM DETAILS.
3. ALL CAT6 COPPER BALANCED TWISTED PAIR CABLING, INSTALLED WITHIN THE
VA MEDICAL FACILITIES/BUILDINGS SHALL BE UL LISTED AND MARKED TYPE
CMP (PLENUM RATED)
KEY NOTES
1. BIOMED EQUIPMENT IN LAB SHALL TIE TO EXISTING MICU BIOMED PANELS IN
BIOMED ROOM 3E-153. INSTALL CABLE TRAY ABOVE CEILING GRID.
2. ROUTE RG-6 & 4PR UTP TO EXISTING MATV MODULE IN MICU BIOMED ROOM
3E-153
3. PLYWOOD BACKBOARD 3/4 INCHES EXISTING TO REMAIN
4. PACS MODULE - EXISTING TO REMAIN
5. PROVIDE NEW PAC BACKBOARD FOR NEW PACS CONTROLLER TO TIE TO NEW
CARD READERS IN LAB. TWO ADDITIONAL PACS PANELS IN EXISTING MICU
BIOMED ROOM. MATCH EXISTING LAYOUT. SEE DETAILS. COORDINATE WITH
POWER PLAN DRAWING FOR CIRCUIT NUMBER FOR DEDICATED RECEPTACLES.
6. MATV MODULE EXISTING TO REMAIN
7. EXISTING CCTV SYSTEM
A C
I D
H O
O D
CENTRIFUGE
CLEAN DIRTY
VW
XYZ
A
C1
Wn
CORRIDOR
C3F-1
81 SF
IT CLOSET
3F-104
105 SF
ELEC CLOS
3F-102
ACCESSIONING
3F-106a
VW
XYZ
Wn
A
A
A
E A
A
A
A
E A
A
A
A
A
A
A
A
A
A
A
A
E A
A
A
B
BIOMED IN
MICU
EXPANSION
3E111
Coax-RG11 Coax-RG11 Coax-RG11
C o a x R
G
C o a x R
G
C o a x R
G
C o a x R
G
C o a x R
G
C o a x R
G
C o a x R
G
C o a x R
G
Coax-RG11 Coax-RG11 Coax-RG11 Coax-RG11
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
KEYPLAN
LAB EXPANSION
PLAN
NORTH
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
TN
N
3RD FLOOR CONNECTION
TELECOMMUNICATION PLAN
TN132
DKSGGR/DKS
16'0 8' 24'
SCALE:1/4"=1'-0"
SCALE:
TN132
3RD FLOOR CONNECTION TELECOMMUNICATION PLAN
1/4" = 1'-0"
TN431
P V A D
U
V A
R i c h m o n d
L a b D r a w i n g s T e l e c o m
V A D
U
R I C H
M O
B
T e l e c a n
T N d w g
P M
A R l l b l e e d
E x
I n c h e s
CABLE TRAY FOR
HORIZONTAL CABLES
MOUNTED SUCH THAT
THE BOTTOM OF TRAY
IS 6 INCHES ABOVE
TOP OF RACK
F R
O N
T
R E
A R
F R
O N
T
R E
A R
1'-0"
DOUBLE (FRONT/REAR)
VERTICAL WIRE MANAGERS
BUS GROUND SURFACE
MOUNTED AT 18"AFF. PROVIDE
TELECOMMUNICATIONS BONDING
BACKBONE (EDM 8.3), AND
CONDUIT CONNECTIVITY (EDM
TABLE 7-1) SEE DETAIL 1 ON
SHEET TN501
OIT CONDUITS
3'-0"
CLEARANCE
TG
B
1'-8"
CLEARANCE
1'-9"
CLEARANCE
0'-4"
BLACK 19" WIDE BY 84"
HEIGHT EQUIPMENT RACKS
F R
O N
T
R E
A R
1'-3"
TN501
0'-3"
11'-5"
2'-8"
CLEARANCE
7'-0"
GROUND ALL CONNECTION POINTS PER
TIA.607-B. GROUND AND BOND LADDER RACK
OR WIRE MESH TRAY SYSTEMS WITH
APPROVED GROUNDING HARDWARE PER
MANUFACTURER'S SPECIFICATION.
11'-5"
7'-0"
NOTES:
1. WIRE MESH CABLE TRAY SHALL BE USED IN THE TR TO BRING CABLE FROM
OUTSIDE THE ROOM TO LOCATION OF TERMINATION.
2. WIRE MESH TRAYS SHALL BE GROUNDED AT EVERY SPLICE POINT WITH A NUMBER
(#6) THHN COPPER GROUND WIRE AND COPPER GROUNDING LUGS.
MAIN POWER DISTRIBUTION
PLATE
TELECOMMUNICATIONS ROOM (TETR1) NOTES
NOTES:
1) PARTITIONS AND OPENINGS TO COMPLY WITH VA PHYSICAL SECURITY DESIGN MANUAL.
2) PAINTED 3/4-INCH FIRE RETARDANT PLYWOOD OVER GYPSUM WALL BOARD.
3) STATIC DISSIPATIVE VINYL TILE.
4) OPTIONAL WIRE MESH PARTITION TO 96"H WITH LOCKABLE, SLIDING, WIRE MESH GATES (36"W X 93"H) AT EACH OPENING.
PROVIDE TO SEPARATE OIT AND FMS EQUIPMENT IF LOCKABLE ENCLOSURES ARE NOT USED AT RACKS OR CABINETS.
5) IN MULTI-FLOOR BUILDINGS, TRS SHALL BE STACKED VERTICALLY THROUGH THE BUILDING, WITH TRS IN EACH STACK LOCATED
TO ALIGN DIRECTLY ABOVE OR BELOW EACH OTHER.
6) 4" CONDUITS THROUGH FLOOR FOR OIT BACKBONE DISTRIBUTION AT STACKED TRS. 1 CONDUIT REQUIRED FOR EACH TR.
CONDUITS SLEEVED TO TR ABOVE (IF APPLICABLE) ARE NOT SHOWN.
7) 4" CONDUITS THROUGH FLOOR FOR FMS BACKBONE DISTRIBUTION AT STACKED TRS. 2 CONDUITS REQUIRED FOR EACH TR.
CONDUITS SLEEVED TO TR ABOVE (IF APPLICABLE) ARE NOT SHOWN.
8) RACKS AND CABINETS (RACKS SHOWN) ARE CONTRACTOR FURNISHED, CONTRACTOR INSTALLED. SEE EQUIPMENT LIST. SEE
EQUIPMENT MODULES FOR TYPICAL RACK AND CABINET DIMENSIONS AND CLEARANCES,
9) OIT SYSTEMS ARE VA FURNISHED,VA INSTALLED.
10) PROVIDE TELECOMMUNICATIONS BONDING BACKBONE (EDM 8.3), AND CONDUIT CONNECTIVITY (EDM TABLE 7-1).
11) IF WIRE MESH PARTITION IS NOT PROVIDED, PROVIDE CABLE TRAY MOUNTED SUCH THAT BOTTOM OF TRAY IS 6" ABOVE TOP
OF RACK OR CABINET.
12)PROVIDE RE-USABLE PENETRATION FIRESTOPPING SYSTEM, TYPE AND SIZE AS REQUIRED TO MATCH CABLE TRAY
CROSS-SECTIONAL AREA (MCS 07 84 00).
13) SPACE RESERVED FOR WALL-MOUNTED 110 TERMINATION BLOCKS.
14) EXACT QUANTITY, LOCATION, AND LAMPING OF FIXTURES SHALL BE CHOSEN TO MEET THE FOOTCANDLE REQUIREMENT.
15) ALL RECEPTACLES AND EQUIPMENT SHALL BE CONNECTED TO UPS POWER (EDM 5.3), AND THE UPS EQUIPMENT CONNECTED
TO THE CRITICAL BRANCH OF THE ESSENTIAL ELECTRICAL SYSTEM (EDM 4.6).
16) PROVIDE SECURITY SURVEILLANCE TELEVISION CAMERA MOUNTED BELOW CABLE TRAY AND CONNECT TO DATA RACK.
17) DO NOT RUN PIPE CONTAINING LIQUIDS (SUCH AS WATER, DRAIN, OR STEAM) ABOVE THIS SPACE; EXCEPT ONLY AS REQUIRED
TO PROVIDE FIRE SUPPRESSION FOR THIS SPACE.
KEY NOTES
1. RELOCATE AND INSTALL APTIO AUTOMATION ALONG WITH ACCESSORY COMPONENTS, MIDDLEWARE AND INSTRUMENTATION IN ACCORDANCE WITH MANUFACTURER REQUIREMENTS. PROVIDE PATCH CABLES TO JACKS ON EQUIPMENT. IDENTIFY AND LABEL EACH CABLE WITH TYPE WRITTEN RECORD OF CONNECTIONS.
2. PROVIDE DEDICATED DATA CONNECTION BETWEEN CHEMISTRY LINE HARDWARE AND CONTROLLING PC.
REFERENCE MANUFACTURER REQUIREMENTS, AND PROVIDE ACCORDINGLY.
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
3RD FLOOR
ENLARGED PLANS
TN431
DKSGGR/DKS
SCALE:
TN431
CABLE TRAY GROUNDING ROOM 3F105
1/2" = 1'-0"
SCALE:
TN431
NEW TELECOMMUNICATION ROOM 3F105
1/2" = 1'-0"
SCALE:
TN431
VISTA AND CENTRIFUGE AREA TELECOMMUNICATION
1/2" = 1'-0" 2' 4'0 1'
SCALE:1/2"=1'-0"
P V A D
U
V A
R i c h m o n d
L a b D r a w i n g s T e l e c o m
V A D
U
R I C H
M O
B
T e l e c a n
T N d w g
P M
A R l l b l e e d
E x
I n c h e s
TO TR
T U
OPEN
TO
BEYOND
OPEN
TO
BEYOND
WORKSTATION
#3
WORKSTATION
#2
WORKSTATION
#1
WORKSTATION
#4
BOOKSHELVES
ST-2 ST-1
BD-2
BD-3/4
BD-5
TO TRTO TR
TN432
TELECOM ELEVATIONS
GGR/DKS
DKS
REVISIONS DATE
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
VA FORM 08 - 6231
A
F i l e
P a t h
FULLY
SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE:
ARCHITECT/ENGINEER OF RECORD
SEAL
CONSULTANT
321 4 5 6 7 8 9 10
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
PROJECT DIRECTOR
AUGUST 2018
REVISIONS: DATE:
Group, Inc.
11031 SOUTH PIKES PEAK DRIVE #202
PARKER, COLORADO 80138
PH: 303.841.3922
WWW.AES-GRP.COM
BID DOCUMENTS
DWG. OF 162
NAME: TINA DEBELLA, PE
PHONE: 804.675.5495
EMAIL: Tina.DeBella@va.gov
SCALE:
TN432
ANCILLARY TESTING - PLAN EAST
NOT TO SCALE
SCALE:
TN432
MICROBIOLOGY ISLAND - PLAN SOUTH
NOT TO SCALE
NOTE: PROVIDE THREE-CHANNEL RACEWAYS
AND POWER POLES WHERE REQUIRED TO
ACCOMMODATE MULTIPLE ELECTRICAL
SYSTEMS AND TELECOM.
NOTE: PROVIDE THREE-CHANNEL RACEWAYS
AND POWER POLES WHERE REQUIRED TO
ACCOMMODATE MULTIPLE ELECTRICAL
SYSTEMS AND TELECOM.
P V A D
U
V A
R i c h m o n d
L a b D r a w i n g s T e l e c o m
V A D
U
R I C H
M O
B
T e l e c a n
T N d w g
P M
A R l l b l e e d
E x
I n c h e s
WAP
NOTES
1. PROVIDE THREE (3) RACK ANCHOR INSTALLATION KIT, B-LINE OR EQUIVALENT.
2. PROVIDE A NETWORK OF FIBER OPTIC, UNSHIELDED TWISTED PAIR, RISER, AND TIE CABLES AS REQUIRED TO SERVICE ALL DEVICES ON PLANS WITH
ADDITIONAL CAPACITY PER SCECIFICATIONS
3. EQUIPMENT RACK SHALL BE ABLE TO SUPPORT FIBER OPTIC TERMINATION HOUSING; CATEGORY 6 ANGLED PATCH PANELS, NETWORKING AND TELCO
ELECTRONIC GEAR.
4. PROVIDE ONE (1) FIBER CABINET ENCLOSURE CONNECTOR PANELS LC, SINGLE-MODE.
5. PROVIDE ONE (1) FIBER CABINET ENCLOSURE CONNECTOR PANELS LC, MULTI-MODE.
6. PROVIDE FOUR (4) VERTICAL CABLE MANAGERS W/ HINGED DOORS, B-LINE.
7. PROVIDE TWO (2) QUAD 15A WALL OUTLETS INSTALLED ON WIRE MESH CABLE TRAY OR CABLE RUNWAY ABOVE EACH RACK.
8. PROVIDE TWO (2) L6-30 WALL POWER OUTLET FOR THE UPS INSTALLED AT THE BASE OF EACH RACK.
9. ALL ELECTRICAL POWER MUST BE TIED TO EMERGENCY POWER.
10. TELECOMMUNICATION ROOM NEEDS SEPARATE ENVIRONMENTAL UNIT FOR HEATING AND COOLING.
11. PROVIDE UPS (MANUFACTURER NAME: TRIPP-LITE, MANUFACTURER PART # SMART5000RT3U. (120V, OUTPUT/208V INPUT).
12. PROVIDE UPS WITH 24X7 1 YEAR EXTENDED MANUFACTURER'S WARRANTY.
SYMBOL ON PLANS -
STATION CABLES SHALL BE CAT 6
PLENUM RATED CABLE, YELLOW IN
COLOR FOR DATA
CABLE TRAY TO FLOOR
DISTRIBUTION FRAME (FDF)
OR COMMUNICATIONS
EQUIPMENT ROOM (CER).
1" CONDUIT TO CABLE TRAY WITH
PULLING CORD.
3 1
STATION CABLES SHALL BE CAT 6
PLENUM RATED CABLE, BLUE IN COLOR
FOR VOICE
CATEGORY 6
ANGLED PATCH
PANELS, 568A/B,
48-PORT RACK
MOUNT.
4.50"
2.75"
TEN (10) PIN 568A/B
CAT 6 KEYSTONE
JACK FOR VOIP (BLUE)
TEN (10) PIN 568A/B
CAT 6 KEYSTONE
JACK FOR DATA
(YELLOW)
LABELS UNDER
PLASTIC
WINDOWS
NOTES
1. VOICE JACKS SHOULD ALWAYS BE ON TOP AND DATA JACKS ON THE BOTTOM OF THE FACEPLATE.
2. DESIGNER FACEPLATE :
A) 4-PORT FACEPLATES SHALL BE CONTEMPORARY CONTOUR STYLE
B) PHYSICAL SPECIFICATIONS: 4.81-IN H X 2.84-IN W X 0.33-IN D
C) 4-PORT SURFACE MOUNT BOXES (SMB) SHALL FEATURE A COMPACT LOW PROFILE OUTLINE.
D) PHYSICAL SPECIFICATIONS: 4.52" X 1.10" X 3.27"
3. STANDARD FACEPLATE COLOR: IVORY
NOTES
1. LABEL ALL OUTLETS AS SHOWN ABOVE UNLESS OTHERWISE INDICATED
BY COR
2. ROOM NUMBER -V1/V2, TR-D1/D2.
FOR EXAMPLE: 2A101-V1/V2, 2TA-D1/ D2
WHERE 2A101 IS THE ROOM # AND 2TA IS THE TR LOCATION.
3. PLACE LABELS UNDER PLASTIC WINDOWS PROVIDED IN THE FACEPLATES
PACKAGE.
4. VOICE JACKS SHOULD ALWAYS BE ON TOP AND DATA JACKS ON THE
BOTTOM OF THE FACEPLATE.
5. LABELS SHALL NOT BE WRITTEN BY HAND.
RO…