This federal contract opportunity notice seeks construction services for a clinical lab expansion project located at a VA medical center in Richmond, Virginia. Key details include the project scope of a partial renovation and 18,050 square foot addition, a construction cost between $5-10 million, a 680 calendar day period of performance, and a NAICS code of 236220 with a $36.5 million small business size standard. The solicitation will be issued on August 15th and include drawings, specifications, and a pre-proposal site visit date. Questions must be emailed to the listed contracting officer by the specified due date. This is a 100% SDVOSB set-aside where only offers from SDVOSB concerns will be considered.
36C24619B0039 S02 STRUCTURAL_Bid_Documents.pdf
View the file
Other files for this federal contract opportunity
Show all 39
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCOPE
THIS SPECIFICATION OUTLINES THE STRUCTURAL DESIGN CRITERIA FOR A SINGLE
STORY 3RD LEVEL ADDITION TO THE VA MEDICAL CENTER IN RICHMOND, VA. WHEN
A DIFFERENCE EXISTS BETWEEN THIS SPECIFICATION AND ANY OTHER GOVERNING
CODE, THE MORE STRINGENT SHALL CONTROL. ANY OTHER ITEMS NOT COVERED
THEREIN SHALL BE COMMENSURATE WITH GOOD ENGINEERING PRACTICE.
THESE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH CIVIL,
ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS AND
SPECIFICATIONS.
DESIGN STANDARDS
1. INTERNATIONAL BUILDING CODE, 2015 EDITION.
2. INTERNATIONAL EXISTING BUILDING CODE, 2015 EDITION.
3. AMERICAN SOCIETY OF CIVIL ENGINEERS - ASCE 7-10.
4. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE.
5. MSJC 2013, BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY
STRUCTURES AND RELATED COMMENTARIES.
6. AISC STEEL CONSTRUCTION MANUAL, 14TH EDITION, 2010.
7. AISI S-100 – 12, NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD
FORMED STEEL STRUCTURAL MEMBERS.
8. VA SEISMIC DESIGN REQUIREMENTS, H-18-8, 2013.
9. VA STRUCTURAL DESIGN MANUAL 2014.
DESIGN LOADING
1. DEAD LOADS: WEIGHT OF STRUCTURE AND ALL THINGS PERMANENTLY
ATTACHED.
• FLOORS (WAFFLE SLAB) 200 PSF
• INTERSTITIAL 65 PSF
• ROOFS 30 PSF
2. GRAVITY LIVE LOADS:
• LAB FLOOR (INCLUDES PARTITIONS) 75 PSF
• INTERSTITIAL 20 PSF
• ROOFS (NOT REDUCABLE) 20 PSF
3. SNOW LOAD
• GROUND SNOW LOAD Pg = 20 PSF
• FLAT ROOF SNOW LOAD Pf = 17 PSF
• SNOW EXPOSURE FACTOR 1.0
• SNOW IMPORTANCE FACTOR 1.2
• SNOW THERMAL FACTOR 1.0
4. SEISMIC DESIGN CRITERIA
• SITE CLASS D
• SEISMIC IMPORTANCE FACTOR 1.5
• RISK CATAGORY IV
• SEISMIC DESIGN CATAGORY C
• SPECTRAL RESPONSE: Ss = 0.186
S1 = 0.062 Sds = 0.198 Sd1 = 0.099
• SEISMIC RESPONSE COEFFICIENT 0.059
THE EXISTING STRUCTURE SEISMIC FORCE-RESISTING SYSTEM IN THE
NORTH-SOUTH AND EAST-WEST DIRECTIONS IS COMPOSED OF ORDINARY
REINFORCED CONCRETE SHEAR WALLS. THE SEISMIC FORCE RESISTING
SYSTEM FOR THE EXPANSION STRUCTURE IN BOTH THE NORTH-SOUTH
AND EAST-WEST DIRECTIONS IS COMPOSED OF STEEL SYSTEM NOT
SPECIFICALLY DESIGNED FOR SEISMIC RESISTANCE (R = 3). SEISMIC
ANALYSIS WAS PERFORMED USING THE EQUIVALENT LATERAL FORCE
PROCEDURE
5. WIND LOAD
• ANALYSIS PROCEDURE DIRECTIONAL
• BASIC WIND SPEED (1700 YR MRI) 120 MPH (3-SEC GUST)
• MEAN ROOF HEIGHT 54 FT
• RISK CATAGORY IV
• EXPOSURE CATAGORY C
• INTERNAL PRESSURE COEFFICIENT +/- 0.18
NOTES:
1. DESIGN PRESSURES ARE FOR STRENGTH DESIGN. MULTIPLY BY 0.6 FOR
ALLOWABLE STRESS DESIGN.
2. TABLE PRESSURES ARE FOR THE SQUARE FOOT (SF) TRIBUTARY AREA
SHOWN. FOR TRIBUTARY AREAS BETWEEN VALUES SHOWN, INTERPOLATE
BASED ON TRIBUTARY AREA TO OBTAIN DESIGN PRESSURE.
3. VALUES ABOVE INCLUDE INTERNAL PRESSURE COEFFICIENT.
4. REFER TO CHAPTER 30 OF ASCE 7-10 FOR ADDITIONAL INFORMATION
INCLUDING DEFINITION OF ZONES.
5. POSITIVE PRESSURE ACTS TOWARDS THE BUILDING, NEGATIVE PRESSURE
ACTS AWAY FROM THE BUILDING.
(AS APPLICABLE TO EACH PHASE OF CONSTRUCTION, UNLESS NOTED OTHERWISE)
1. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. DO NOT SCALE DRAWINGS.
2. DO NOT REPRODUCE CONTRACT DOCUMENTS OR COPY STANDARD PRINTED
INFORMATION AS BASIS OF SHOP DRAWINGS.
3. CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION PRACTICES INCLUDING
TECHNIQUES, PROCEDURES AND THE SEQUENCE OF CONSTRUCTION.
CONTRACTOR SHALL NOTIFY STRUCTURAL ENGINEER IF A CONFLICT ARISES DUE
TO VARIATIONS OR OTHER PROBLEMS WITH THE CONSTRUCTION DOCUMENTS.
4. THIS STRUCTURE HAS BEEN DESIGNED FOR IN SERVICE LOADS ONLY. DURING
ERECTION OF THE BUILDING, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
TEMPORARY BRACING TO WITHSTAND ALL LOADS TO WHICH THE STRUCTURE
MAY BE SUBJECTED, INCLUDING LATERAL LOADS, STOCKPILES OF MATERIALS
AND EQUIPMENT. SUCH BRACING SHALL BE LEFT IN PLACE AS LONG AS MAY BE
REQUIRED FOR SAFETY AND UNTIL ALL STRUCTURAL FRAMING AND DIAPHRAGMS
ARE IN PLACE WITH CONNECTIONS COMPLETED.
5. OBSERVATIONS OF JOBSITE OTHER THAN REQUIRED INSPECTIONS BY ENGINEER
ARE NOT CONSTRUCTION APPROVALS.
6. STRUCTURAL ENGINEER MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY
REQUIRED CONSTRUCTION OBSERVATION.
7. NO UNBALANCED BACKFILLING SHALL BE DONE AGAINST MASONRY OR
CONCRETE WALLS UNLESS WALLS ARE SECURELY BRACED AGAINST
OVERTURNING, EITHER BY TEMPORARY CONSTRUCTION BRACING OR BY
PERMANENT CONSTRUCTION.
8. PROVIDE SLEEVES FOR ALL PIPES PLACED THROUGH CONCRETE BEAMS, WALLS,
COLUMNS OR SLABS.
9. VERIFY ALL OPENINGS THROUGH FLOOR, ROOF, AND WALLS WITH MECHANICAL
AND ELECTRICAL CONTRACTORS.
1. EXPANSION ANCHORS
• EXPANSION ANCHORS CALLED FOR ON THE DRAWINGS SHALL BE WEDGE TYPE
EXPANSION ANCHORS UNO.
• EXPANSION ANCHORS IN CONCRETE OR SOLID GROUTED MASONRY SHALL BE
MIN 7 TIMES THE INSERT DIAMETER, UNO.
• ACCEPTABLE WEDGE TYPE EXPANSION ANCHORS IN CONCRETE ARE:
• KWIK BOLT TZ BY HILTI CORPORATION
• TRUBOLT+ BY ITW REDHEAD
• POWERSTUD+ SD1 OR SD2 BY POWERS FASTENERS
• STRONG-BOLT BY SIMPSON STRONG-TIE
• ACCEPTABLE DROP-IN EXPANSION ANCHORS IN CONCRETE ARE:
• HDI SERIES BY HILTI CORPORATION
• DROP-IN (DIA) BY SIMPSON STRONG-TIE
2. ADHESIVE ANCHORS
• EPOXY SHALL CONFORM TO ASTM C-881, TYPE IV, GRADE 2 WITH CLASS
SUITABLE FOR ENVIRONMENTAL CONDITIONS.
• EMBEDMENT INTO CONCRETE OR SOLID GROUTED MASONRY SHALL BE AT
LEAST 9 TIMES THE INSERT DIAMETER, UON.
• ACCEPTABLE EPOXIES FOR ANCHORING TO EXISTING CONCRETE ARE:
• PE1000+ BY POWERS FASTENERS
• HIT-HY 200 AND HIT-RE 500-SD BY HILTI CORPORATION
• SET-XP BY SIMPSON STRONG-TIE
• ACCEPTABLE EPOXIES FOR ANCHORING TO CMU ARE:
• HIT-HY 70 BY HILTI CORPORATION
• THREADED STEEL RODS SHALL BE UNGREASED WITH Fy = 58KSI MIN AND Fu =
72KSI MIN, UNO.
3. SCREW ANCHORS
A. SCREW ANCHOR EMBEDMENT INTO CONCRETE OR SOLID GROUTED MASONRY
SHALL BE AT LEAST 9 TIMES THE INSERT DIAMETER, UON.
• KWIK HUS-EZ BY HILTI CORPORATION
• TITEN HD BY SIMPSON STRONG-TIE
1. CONCRETE SHALL BE PROPORTIONED, MIXED, CONVEYED, AND PLACED IN
ACCORDANCE WITH ACI 301.
2. MATERIALS SHALL BE AS FOLLOWS:
• CONCRETE 28 DAY MINIMUM COMPRESSIVE STRENGTH:
• FOOTINGS - SELF-CONSOLIDATING CONCRETE 5000 PSI
• OTHER - LIGHTWEIGHT CONCRETE, UNO 4000 PSI
• WATER CEMENT RATIO BY WEIGHT 0.45
• STEEL REINFORCING BARS ASTM A615, GRADE 60
• STEEL REINFORCING BARS THAT ARE FIELD BENT ASTM 706, GRADE 60
• WELDED WIRE FABRIC ASTM A185
• ANCHOR BOLTS / RODS ASTM F1554, GRADE 55
• GROUT, HIGH STRENGTH/LOW SHRINK DRY PACK ASTM C1107
• MINIMUM COMPRESSIVE STRENGTH 5,000 PSI
3. CONCRETE PROTECTION FOR REINFORCEMENT (COVER) SHALL BE AS FOLLOWS:
• CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3"
• CONCRETE EXPOSED TO EARTH OR WEATHER (#5 AND SMALLER): 1.5"
• CONCRETE EXPOSED TO EARTH OR WEATHER (#6 AND LARGER): 2"
• CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
• WALLS, SLABS, AND JOIST TOP BARS (#11 AND SMALLER): 0.75"
• BEAMS, COLUMNS, AND JOIST BOTTOM BARS: 1.5"
4. DETAIL BARS IN ACCORDANCE WITH THE LATEST EDITIONS OF ACI315 AND ACI318.
5. NO SPLICES OF REINFORCEMENT SHALL BE MADE AND NO WELDING TO
REINFORCING SHALL BE PERMITTED EXCEPT AS DETAILED OR AUTHORIZED BY THE
STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALL BE PER THE
REBAR DEVELOPMENT LENGTH TABLE. WIRE FABRIC REINFORCEMENT MUST LAP
12" AND SHALL BE WIRED TOGETHER. MAKE ALL BARS CONTINUOUS AROUND
CORNERS OR PROVIDE CORNER BARS OF EQUAL SIZE AND SPACING.
6. CONTINUOUS BARS IN BEAMS SHALL BE SPLICED AT MID-SPAN FOR TOP BARS AND
OVER SUPPORTS FOR BOTTOM BARS, UNLESS NOTED OTHERWISE.
7. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING BARS AT
POSITIONS SHOWN ON THE PLANS.
8. PIPES AND CONDUITS MAY PASS THROUGH CONCRETE STRUCTURAL ELEMENTS,
BUT SHALL NOT BE EMBEDDED WITHIN THE ELEMENT UNLESS SPECIFICALLY
DETAILED TO CONFORM TO THE FOLLOWING REQUIREMENTS:
• SHALL CONFORM TO TYPICAL CONCRETE PENETRATION DETAILS
• SHALL NOT DISPLACE OR BE IN CONTACT WITH REINFORCING BARS
• CONDUIT AND PIPES SHALL NOT DISPLACE MORE THEN 4% OF CONCRETE
TRIBUTARY AREA
• PIPES AND CONDUIT SHALL NOT CONTAIN ALUMINUM
• CONTRACTOR SHALL SUBMIT DETAILS OF CONDUIT/PIPING LOCATIONS TO THE
ENGINEER FOR REVIEW AND APPROVAL
9. CAST-IN-PLACE CONCRETE SHALL NOT HAVE CONSTRUCTION JOINTS IN A
HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK MUST BE MADE IN THE NORTH-
SOUTH DIRECTION AT QUARTER-POINTS OF THE BEAM SPAN WITH VERTICAL
BULKHEADS AND HORIZONTAL KEYS, UNLESS OTHERWISE SHOWN IN DETAILS.
CONTRACTOR SHALL SUBMIT PROPOSED LOCATIONS OF CONSTRUCTION JOINTS.
10. PROVIDE 3/4" CHAMFER AT ALL EXPOSED CORNERS.
11. ALL CONCRETE SHALL BE CONSOLIDATED BY VIBRATION SO THAT CONCRETE
COMPLETELY SURROUNDS REINFORCING AND EMBEDDED ITEMS WITHOUT
SEGREGATION.
12. DESIGN AND CONSTRUCT FORMWORK IN ACCORDANCE WITH THE LATEST EDITION
OF ACI 347.
1. DETAIL, FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH THE
LATEST PROVISIONS OF AISC MANUAL OF STEEL CONSTRUCTION, CODE OF
STANDARD PRACTICE AND CHAPTER 22 OF THE IBC PER THE REQUIREMENTS OF
THE AUTHORITY HAVING JURISDICTION.
2. MATERIALS SHALL BE AS FOLLOWS UNO:
• PLATES AND ANGLES ASTM A36
• WIDE FLANGE SHAPES ASTM A992
• HOLLOW STRUCTURAL SECTIONS ASTM A500, GRADE B
• PIPE COLUMNS ASTM A53, GRADE B
• HIGH STRENGTH BOLTS ASTM A325, U.N.O.
• PLAIN WASHERS ANSI B18.22.1 65 (R2008)
• WELDING ELECTRODES SHALL BE E70XX RODS CONFORMING TO AWS A5.20
(FCAW PROCESS), AWS A5.18 (GMAW PROCESS) OR AWS A5.1 (SMAW PROCESS)
3. WELDING SHALL BE PERFORMED BY AN AWS CERTIFIED WELDER.
4. WELDING PROCEDURES ARE THE RESPONSIBILITY OF THE STRUCTURAL STEEL
CONTRACTOR.
5. ALL WELDS SHALL BE 3/16" FILLET WELDS WHERE NO SIZE IS PROVIDED AND ALL
WELDS SHALL BE CONTINUOUS WHERE NO LENGTH IS PROVIDED.
6. ALL GROOVE AND BUTT WELDS SHALL BE FULL PENETRATION WELDS AND SHALL
DEVELOP THE FULL STRENGTH OF THE WEAKER MEMBER.
7. ALL WELDS EXPOSED TO VIEW SHALL BE CLEANED, GROUND SMOOTH AND
PAINTED. PAINTING DONE ON STEEL MEMBERS SHOULD BE AT LEAST 3" FROM FIELD
WELDS UNLESS WELDS ARE COMPLETED. SHOP PRIME AND PAINT STEEL PER THE
OWNER’S SPECIFICATIONS.
8. CONNECTIONS MADE WITH HIGH STRENGTH STEEL BOLTS SHALL CONFORM IN ALL
RESPECTS TO THE CURRENT SPECIFICATIONS FOR STRUCTURAL JOINTS AS
ENDORSED BY AISC.
9. FOR BEARING TYPE CONNECTIONS, BOLTS SHALL BE INSTALLED TO A SNUG TIGHT
CONDITION. THE SNUG TIGHT CONDITION IS DEFINED AS THE TIGHTNESS THAT
EXISTS WHEN ALL PLIES OF A JOINT ARE IN FIRM CONTACT. THIS CONDITION MAY
NORMALLY BE ATTAINED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL
EFFORT OF A PERSON USING AN ORDINARY SPUD WRENCH.
10. DOUBLE NUTS SHALL BE PROVIDED AT ALL CONNECTING POINTS OF BRACING AND
SAG RODS.
11. ALL EXTERIOR STEEL SHALL BE HOT-DIPPED GALVANIZED.
12. STEEL STAIRS SHALL BE DESIGNED, SIGNED AND SEALED BY STEEL FABRICATOR'S
SPECIALTY ENGINEER. SEE ARCHITECTURAL DRAWINGS FOR STAIR
CONFIGURATION.
1. STEEL STUD CONTRACTOR SHALL SUBMIT DRAWINGS AND CALCULATIONS FOR ALL
CONNECTIONS AND FRAMING TO THE CONTRACTING OFFICER REPRESENTATIVE
FOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER PRIOR TO
FABRICATION OR ERECTION.
2. ALL COLD-FORMED STEEL FRAMING SHALL BE DESIGNED IN ACCORDANCE WITH
AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF
COLD-FORMED STEEL STRUCTURAL MEMBERS".
3. ALL FRAMING SHALL BE GALVANIZED, ASTM 924 COATING.
4. STUDS SHALL BE PLUMB, ALIGNED, AND FULLY NESTED IN BOTH THE UPPER AND
LOWER TRACK.
5. ALL CONNECTIONS SHALL BE SCREWED OR WELDED. SCREWS SHALL CONFORM TO
SAE J78. ATTACH STUDS TO TRACKS WITH A MINIMUM OF (1)#10 TEK SCREW
BETWEEN EACH FLANGE AND THE TRACK. SCREW THREADS SHALL EXTRUDE A
MINIMUM OF 3 EXPOSED THREADS THROUGH STEEL. POWER DRIVEN FASTENERS
(PDF) SHALL COMPLETELY PENETRATE THE STRUCTURAL STEEL.
6. ALL WELDS SHALL BE TOUCHED UP WITH ZINC-RICH PAINT.
7. FRAMING OF WALL OPENINGS SHALL INCLUDE HEADERS AND SUPPORTING STUDS .
8. BLOCKING BETWEEN STUDS SHALL BE PROVIDED. BLOCKING SHALL BE SAME GAGE
AS STUDS.
1. MINIMUM QUALITY ASSURANCE PROGRAM SHALL COMPLY WITH LEVEL B IN
ACCORDANCE WITH TABLE 4 OF ACI 530.
2. MATERIALS SHALL BE AS FOLLOWS:
• MASONRY COMPRESSIVE STRENGTH (f'm) 1,500 PSI
• STEEL REINFORCING BARS ASTM A615, GRADE 60
• WIRE JOINT REINFORCEMENT ASTM A951M, GRADE 30
• HOLLOW, LIGHTWEIGHT UNITS ASTM C90
• MORTAR: PORTLAND CEMENT OR LIME MORTAR, TYPE S ASTM C270
(MASONRY CEMENT NOT ACCEPTABLE)
• AGGREGATE
• MORTAR ASTM C144
• GROUT ASTM C404
• GROUT ASTM C476, C1019
• PORTLAND CEMENT, TYPE I OR TYPE II ASTM C150
• CONTROL JOINT INSERT (TYPE PVC 654-4) ASTM D2287
• JOINT REINFORCEMENT W1.7 (9 GA) LADDER TYPE ASTM A951
• EXPANSION JOINT - TYPE PVC ASTM D2287
3. PROVIDE CONSTRUCTION PROCEDURES FOR HOT AND/OR COLD WEATHER
CONSTRUCTION AS NEEDED.
4. FACILITATE ACCESS TO THE CONSTRUCTION SITE AND PERFORMANCE OF
ACTIVITIES RELATED TO QUALITY ASSURANCE BY THE TESTING AND INSPECTION
AGENCIES.
5. INSTALL MASONRY TO LINES, LEVELS AND TOLERANCES PER ACI 530.1 IN RUNNING
BOND UNLESS SHOWN OTHERWISE ON DRAWINGS.
6. POSITION AND SECURE ALL REINFORCING, DOWELS, ETC IN PLACE TO PREVENT
EXCESSIVE DISPLACEMENT BY PLACEMENT OF GROUT OR MORTAR.
7. PROVIDE CLEANOUTS IN THE BOTTOM COURSE OF MASONRY FOR EACH GROUT
POUR WHEN THE GROUT POUR HEIGHT EXCEEDS 5 FEET. ALL GROUT POURS
GREATER THAN 12 INCHES REQUIRE INTERNAL MECHANICAL VIBRATION AND
RECONSOLIDATION. GROUT POURS LESS THAN 12 INCHES SHALL BE MECHANICALLY
VIBRATED OR PUDDLED.
8. CONSTRUCT CLEANOUTS SO THAT THE SPACE TO BE GROUTED CAN BE CLEANED
AND INSPECTED. IN SOLID GROUTED MASONRY, SPACE CLEANOUTS HORIZONTALLY
A MAXIMUM OF 32 INCHES ON CENTER.
9. GROUT SOLID ALL CELLS BELOW GRADE.
10. PROVIDE MINIMUM (2) #5 BOND BEAMS AT FLOOR AND ROOF LINES, AT TOP OF
PARAPET AND AT MAXIMUM 10 FOOT VERTICAL SPACING.
11. UNO, PROVIDE MINIMUM (1) #5 AT THE END OF A WALL, AT ALL DOOR AND WINDOW
JAMBS, AND ON ALL SIDES OF OPENINGS (I.E., DOORS AND WINDOWS) WITH
DIMENSIONS GREATER THAN 12 INCHES. PLACE (1) #5 AT ALL WALL CORNERS.
EXTEND REINFORCING MINIMUM 2 FEET BEYOND EDGE OF OPENINGS.
12. STEP BOND BEAMS TO ALIGN WITH FLOORS AND ROOF. LAP BOND BEAMS MINIMUM
4 FEET AT VERTICAL STEPS.
13. MAXIMUM SPACING OF CROSS WIRES IN LADDER TYPE JOINT REINFORCEMENT AND
AT POINTS OF CONNECTION OF CROSS WIRES TO LONGITUDINAL WIRES OF TRUSS-
TYPE JOINT REINFORCEMENT SHALL BE 16 INCHES. SEE DRAWINGS FOR ADDITIONAL
REQUIREMENTS.
14. THICKNESS OF BED JOINTS SHALL NOT EXCEED 5/8 INCH.
15. CONTRACTOR SHALL COORDINATE LOCATION OF CONDUITS, PIPES, AND SLEEVES
WITH PLUMBING, MECHANICAL AND ELECTRICAL PRIOR TO CONSTRUCTION.
16. CONTRACTOR SHALL COORDINATE LOCATIONS FOR CONTROL JOINTS WITH THE
ARCHITECTURAL DRAWINGS. CONTROL JOINT SPACING SHALL NOT EXCEED 20 FEET.
17. TOOL JOINTS CONCAVE WITH ROUND JOINTER.
18. PROVIDE FULL MASONRY BOND AT CORNERS, INTERSECTIONS AND PILASTERS FOR
WALLS LAID IN RUNNING BOND.
19. LAP SLICE REINFORCEMENT 48 BAR DIAMETERS WHERE SPLICES ARE REQUIRED.
20. DESIGN, FABRICATE, CONSTRUCT, ERECT, AND MAINTAIN A PROPER TEMPORARY
BRACING SYSTEM TO PREVENT COLLAPSE OF WALLS. DESIGN TO BE BASED ON ANSI
A10.9 AS A MINIMUM.
21. PROVIDE WATER REPELLENT BLOCK AND MORTAR AT ALL EXTERIOR WALLS.
CONTRACTOR SHALL PROVIDE ADEQUATE SHORING OF WALLS UNTIL SUCH TIME AS
WALLS ARE MADE STABLE BY THE FRAMING AND DIAPHRAGM SYSTEM.
NOTES:
1. 'LD' = DEVELOPMENT LENGTH
'LDH' = HOOK DEVELOPMENT LENGTH WITH STANDARD 90 DEGREE HOOK
'LS' = LAP SPLICE LENGTH
2. WHEN SPLICING DIFFERENT BARS, USE THE MAXIMUM OF THE SMALLER BAR
SPLICE LENGTH OR LARGER BAR DEVELOPMENT LENGTH, UNO.
3. INCREASE LENGTHS PROVIDED BY 50% IF CLEAR COVER IS GREATER THAN (1)
BAR DIAMETER. OR CLEAR SPACING BETWEEN BARS IS LESS THAN (2) BAR
DIAMETERS.
4. ALL HOOK BARS SHALL HAVE 2" COVER OFF FAR FACE OF SUPPORT WITH A 2-
1/2" SIDE COVER, UNO. INCREASE 'LDH' BY 40% IF SIDE COVER IS NOT
ACHIEVED.
5. REFER TO DETAILS ON SE502.
NOTES:
1. 'LD' = TENSION DEVELOPMENT LENGTH
'LDH' = HOOK DEVELOPMENT LENGTH WITH STANDARD 90 DEGREE HOOK
'LS' = LAP SPLICE LENGTH
2. 'TOP' REFERS TO HORIZONTAL REINFORCEMENT BARS W/ MORE THAN 12" OF
FRESH CONCRETE CAST BELOW BAR.
3. ALL BARS THAT ARE NOT 'TOP' ARE 'OTHER' BARS.
4. WHEN SPLICING DIFFERENT BARS, USE THE MAXIMUM OF THE SMALLER BAR
SPLICE LENGTH OR LARGER BAR DEVELOPMENT LENGTH, UNO.
5. INCREASE LENGTHS PROVIDED BY 50% IF CLEAR COVER IS GREATER THAN (1)
BAR DIAMETER. OR CLEAR SPACING BETWEEN BARS IS LESS THAN (2) BAR
DIAMETERS.
6. ALL HOOK BARS SHALL HAVE 2" COVER OFF FAR FACE OF SUPPORT WITH A 2-
1/2" SIDE COVER, UNO. INCREASE 'LDH' BY 40% IF SIDE COVER IS NOT
ACHIEVED.
7. REFER TO DETAIL ON SE502.
LW CONCRETE REBAR DEVELOPMENT LENGTH
F'c = 4000 PSI MINIMUM CONCRETE
DEVELOPMENT LENGTH (IN) SPLICE LENGTH (IN)
LSLD
LDH
BAR
SIZE
TOP OTHERTOP OTHER
# 3 # 4 # 5 # 6 # 7 # 8 # 9
# 10
31 24
EXPANSION BOLT AND ADHESIVE ANCHOR INSTALLATION REQUIREMENTS
1. HOLES SHALL BE DRILLED USING A COARSE CUTTING ROCK CHISEL OR HAMMER
DRILL. CORE DRILLS OR OTHER SMOOTH CUTTING DRILLS ARE NOT ALLOWED.
2. HOLES SHALL BE THOROUGHLY CLEANED WITH A BRUSH, THEN VACUUMED OR
BLOWN CLEAN WITH OIL-FREE COMPRESSED AIR TO REMOVE ALL RESIDUE FROM
THE DRILLING OPERATION.
3. EXPANSION BOLTS AND EPOXY ANCHORS SHALL BE INSTALLED PER
MANUFACTURER’S RECOMMENDATIONS.
MASONRY REBAR DEVELOPMENT LENGTH
F'm = 1500 PSI MINIMUM CONCRETE MASONRY
DEVELOPMENT LENGTH (IN) SPLICE LENGTH (IN)
LSLD
LDH
BAR
SIZE
8-IN CMU 12-IN CMU8-IN CMU 12-IN CMU
# 3 # 4 # 5 # 6 # 7 # 8 # 9
NP
15 16 15
15 NP
1. ALL STEEL DECKING SHALL BE DESIGNED AND DETAILED IN ACCORDANCE WITH THE
LATEST PROVISIONS OF THE STEEL DECK INSTITUTE'S SPECIFICATIONS AND CODE
OF STANDARD PRACTICE.
2. ALL SHEET STEEL FOR GALVANIZED DECK SHALL CONFORM TO ASTM A653
STRUCTURAL QUALITY, WITH A MINIMUM YIELD STRENGTH OF 33 KSI.
3. ALL SHEET STEEL FOR COLD ROLLED PLUS PAINTED DECK SHALL CONFORM TO
ASTM A1008 WITH A MINIMUM YIELD STRENGTH OF 33 KSI.
4. PROVIDE ANGLE SUPPORT (USE 2-1/2x2-1/2x1/4) ALONG THE FACE OF STEEL
COLUMNS WHERE METAL DECK OR GRATING SPANS INTO IT.
5. NON-COMPOSITE STEEL FLOOR DECK SHALL BE ATTACHED WITH 5/8" Ø PUDDLE
WELDS (USE WELD WASHERS WHEN DECK IS LESS THAN 22 GA). WELD SIDELAPS
EACH SIDE AT EACH BEAM OR JOIST. PROVIDE WELDS AT 12" AT END LAPS.
PROVIDE PERIMETER WELDS AT 12" O.C. MAX.
6. STEEL DECKS SHALL BE INSTALLED IN A MINIMUM 3 SPAN CONDITION, UNLESS
NOTED OTHERWISE.
DESIGN CRITERIA GENERAL CONDITIONS
FASTENERS IN CONCRETE AND MASONRY
04 20 00 CONCRETE MASONRY REQUIREMENTS
05 12 00 STRUCTURAL STEEL REQUIREMENTS
05 31 00 STEEL DECKING REQUIREMENTS
05 40 00 COLD FORMED STEEL REQUIREMENTS
03 30 53 CAST-IN-PLACE CONCRETE REQUIREMENTS
1. FOUNDATION DESIGN CRITERIA FOR THE EXISTING BUILDING FROM THE
GEOTECHNICAL DESIGN REPORT PREPARED BY WOODWARD-CYLDE
CONSULTANTS AS LISTED ON SHEET S148 OF DRAWING SET BY WILLIAMS AND
TAZEWELL/PERKINS AND WILL DATED JUNE 23, 1978 FORM THE BASIS FOR THE
STRUCTURAL ANALYSIS OF THE EXISTING BUILDING.
2. PER NOTE #2 ON THE CONCRETE COLUMN SCHEDULE, AS-BUILT SHEET S97, THE
ULTIMATE SOIL BEARING PRESSURES ARE 1.6 TIMES THE ALLOWABLE BEARING
PRESSURES PROVIDED IN THE SCHEDULE.
3. THE FOLLOWING SOIL PROPERTIES HAVE BEEN USED IN THE ANALYSIS OF THE
EXISTING SHALLOW SPREAD FOUNDATIONS:
A. ALLOWABLE SOIL BEARING PRESSURE: 5000 OR 7000 PSF (PER SCHEDULE)
B. ULTIMATE SOIL BEARING PRESSURES: 8000 OR 11,200 PSF
FOUNDATIONS
EXTERIOR WALL SYSTEM NOTES:
THE CONTRACTOR SHALL RETAIN A LICENSED PROFESSIONAL ENGINEER TO DESIGN
THE EXTERIOR WALL FRAMING SYSTEM, INCLUDING THE COLD-FORMED NON-LOAD
BEARING WALL FRAMING. FRAMING AT OPENINGS AND VENEER SUPPORT
ATTACHMENTS. REFER TO ARCHITECTURAL DRAWINGS FOR MATERIAL, FRAMING
CONFIGURATION, AND DETAILS. REFER TO THE GENERAL NOTES ON THIS SHEET FOR
DESIGN LOADS. REFER TO COLD-FORMED METAL FRAMING SPECIFICATIONS 05 40 00
FOR COLD FORMED FRAMING DESIGN REQUIREMENTS AND ADDITIONAL DESIGN LOAD
INFORMATION. REFER TO METAL FABRICATIONS SPECIFICATION 05 50 00 FOR HOT-
ROLLED STEEL DESIGN REQUIREMENTS WHERE ANY SUCH SECTIONS ARE
DETERMINED TO BE NECESSARY FOR STRENGTH OR STIFFNESS. REFER TO SHEET
SE504 FOR FRAMING INFILL REQUIREMENT AT PARAPET.
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE001
GENERAL STRUCTURAL NOTES
AUGUST 2018 RID JWV
BID DOCUMENTS
-106 -81 -635P +155 +128 +108 -69 -52 -415 +37 +31 +26 -75 -66 -604P +124 +102 +86 -37 -33 -304 +37 +31 +26
ZONE 10 SF 100 SF > 500 SF
WALLS (PSF)
-117 -102 -973 +16 +16 +16 -86 -75 -712 +16 +16 +16
- 55 -48 -451 +16 +16 +16
ZONE 10 SF 50 SF > 100 SF
ROOF (PSF)
COMPONENT & CLADDING WIND PRESSURES
REVISIONS DATE
ITEM
POST INSTALLED
ANCHORS*
SLUMP, AIR CONTENT,
AND TEMPERATURE
WHEN SAMPLES ARE
TAKEN FOR STRENGTH
TESTS SPECIMENS
OBTAIN TEST SPECIMEN EACH
100CY/MIX/DAY AT POINT OF CONCRETE
PLACEMENT. ADJUST FREQUENCY AS
REQUIRED TO PROVIDE MINIMUM 5 TOTAL
TESTS PER MIX BUT NOT MORE THAN ONE
SAMPLE PER TRUCK LOAD. SLUMP SHALL
BE AS SUBMITTED IN MIX DESIGN +/-1.5".
CONTINUOUS
ACI 318:
17.8.2.4 & 17.8.2
HOLE DEPTH, DIAMETER, & CLEANLINESS
SHALL BE INSPECTED PRIOR TO
INSTALLATION OF EXPANSION ANCHORS OR
PLACEMENT OF EPOXY FOR ADHESIVE
ANCHORS FOR ALL ANCHORS.
USE OF REQUIRED
MIX DESIGN
ACI 318: CH19,
26.4.3, 26.4.4
VERIFY USE OF APPROVED DESIGN
MIXTURE FOR EACH TRUCK LOAD.
*ADHESIVE ANCHORS INSTALLED IN A HORIZONTAL TO UPWARDLY CONDITION SHALL BE INSTALLED
BY A CERTIFIED INSTALLER.
CONTINUOUS
ASTM C 172,
ASTM C31 &
ACI 318: 26.4.5
& 26.12
FREQUENCY CODE
REFERENCE
REMARKS
SPECIAL INSPECTIONS FOR CONCRETE CONSTRUCTION
ITEM
CONTINUOUS
PERIODIC
FREQUENCY CODE
REFERENCE
REMARKS
SPECIAL INSPECTIONS FOR STEEL CONSTRUCTION
PERIODIC
MATERIAL OF HIGH STRENGTH BOLTS, NUTS, AND WASHERS
VERIFY MARKINGS
CONFORM TO ASTM
STANDARDS INDICATED
IN DRAWINGS
AISC 360, SEC
A3.3 &
APPLICABLE
ASTM STANDARD
PERIODIC
MANUFACTURER'S
CERTIFICATE OF
COMPLIANCE
INSPECTION OF HIGH STRENGTH BOLTING
PERIODICSNUG TIGHT JOINTS AISC 360, SEC
M2.5
MATERIAL VERIFICATION OF STRUCTURAL STEEL
PERIODIC
STRUCTURAL STEEL,
IDENTIFICATION
MARKINGS CONFORM
TO AISC 360
PERIODIC
OTHER STEEL,
IDENTIFICATION
MARKINGS CONFORM
TO APPROPRIATE ASTM
STANDARD IDENTIFIED
IN THE CONSTRUCTION
DRAWINGS
PERIODIC
MANUFACTURER'S
CERTIFIED TEST
REPORTS APPLICATION
TECHNIQUES
AISC 360, SEC
M5.5
APPLICABLE
ASTM
STANDARD
COMPLETE/PARTIAL
JOINT PENETRATION
GROOVE WELDS
MULTI PASS FILIT
WELDS
SINGLE PASS FILIT
WELDS 5/16"
INSPECTION OF STRUCTURAL STEEL AND STEEL DECK WELDING
AWS D1.1
SINGLE PASS FILIT
WELDS > 5/16"
PLUG & SLOT WELDS
INSPECTION OF STEEL FRAME JOINT DETAILS
CONTINUOUS
CONTINUOUS
CONTINUOUS
PERIODIC
DETAILS SUCH AS
BRACING & STIFFENING
MEMBER LOCATIONS
PERIODIC
PERIODIC
APPLICATION OF JOINT
DETAILS AT EACH
CONNECTION
PERIODIC
WHERE THE INSPECTOR QUESTIONS
WELDS, NONDESTRUCTIVE TESTING
SHALL BE PERFORMED
1. SPECIAL INSPECTIONS SHALL BE PERFORMED FOR THE WORK INDICATED BELOW. SPECIAL INSPECTION SHALL BE PERFORMED IN ACCORDANCE WITH SECTIONS 110 AND 1705 OF THE IBC. A QUALIFIED TESTING AGENCY APPROVED BY THE VETERANS AFFAIRS OFFICE & RETAINED BY THE CONTRACTING OFFICER'S REPRESENTATIVE (COR) SHALL PERFORM ALL OTHER SPECIAL INSPECTIONS. THE SPECIAL INSPECTOR SHALL FURNISH COPIES OF ALL INSPECTION RESULTS TO THE COR, ARCHITECT, STRUCTURAL ENGINEER, AND
CONTRACTOR.
2. THE CONTRACTOR SHALL NOTIFY THE SPECIAL INSPECTOR THAT THE WORK IS READY FOR INSPECTION AT LEAST 48 HOURS BEFORE SUCH INSPECTION IS TO OCCUR. ALL WORK REQUIRING SPECIAL INSPECTION SHALL REMAIN ACCESSIBLE AND EXPOSED UNTIL IT HAS BEEN OBSERVED AND INDICATED TO BE IN CONFORMANCE BY THE SPECIAL INSPECTOR. THE CONTRACTOR SHALL MAINTAIN JOBSITE COPIES OF ALL
REPORTS SUBMITTED BY THE SPECIAL INSPECTOR.
3. PERIODIC SPECIAL INSPECTION = SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. WHERE PERIODIC INSPECTIONS ARE INDICATED, A MINIMUM OF 3 INSPECTIONS SHALL BE PERFORMED UNLESS DIRECTED
OTHERWISE BY THE CONTRACTING OFFICER REPRESENTATIVE.
4. CONTINUOUS SPECIAL INSPECTION = SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS PRESENT
WHEN AND WHERE THE WORK TO BE INSPECTED IS BEING PERFORMED.
THE FOLLOWING SPECIAL INSPECTIONS ARE REQUIRED:
QUALITY ASSURANCE
REINFORCING STEEL
PLACEMENT
ACI 318: CH 20,
25.2, 25.3, 26.5.1-26.5.3
VERIFY GRADE, SIZE, BAR QUANTITY,
LOCATION, SPACING, COVER, HOOK AND
SPLICE LENGTH, HOOK & SPLICE LOCATIONS,
BEND DIAMETER, & SUPPORT PRIOR TO EACH
CONCRETE POUR
PERIODIC
ANCHORS TO BE
INSTALLED IN
CONCRETE PRIOR TO &
DURING PLACEMENT
ACI 318:
17.8.2
VERIFY TYPE, DIAMETER, LENGTH, FINISH
& BASE MATERIAL PRIOR TO CONCRETE
POUR
PERIODIC
CONCRETE
PLACEMENT FOR
PROPER APPLICATION
TECHNIQUES
CONTINUOUS
ACI 318:
26.4.5
VERIFY CONCRETE CONSOLIDATION &
COMPACTION BY VIBRATION DURING EACH
PLACEMENT.
MAINTENANCE OF
SPECIFIED CURING
TEMPERATURE &
TECHNIQUES
PERIODIC
ACI 318:
26.4.7-26.4.9
IN-SITU CONCRETE
STRENGTH PRIOR TO
REMOVAL OF SHORING
& FORMS FROM BEAMS
& STRUCTURAL SLABS
ACI 318:
26.10.2
TESTS PER SCHEDULE BELOW:
• 7 DAYS: (1) 6X12 OR (1) 4X8
• 28 DAYS: (2) 6X12 OR (3) 4X8
• 56 DAYS: (1) 6X12 OR (2) 4X8 (IF 28 DAY
TESTS DO NOT ACHIEVE SPECIFIED 28 DAY
STRENGTH.
PERIODIC
FORMWORK FOR
SHAPE, LOCATION &
DIMENSIONS
ACI 318:
26.10.1(b)
INSPECT FIRST CONCRETE PLACEMENT FOR
EACH MEMBER TYPE (WALLS, COLUMNS,
BEAMS, JOISTS AND SLABS).
PERIODIC
ITEM FREQUENCY CODE
REFERENCE
REMARKS
LEVEL 1 SPECIAL INSPECTIONS FOR MASONRY CONSTRUCTION
VERIFY COMPLIANCE
WITH REQUIRED
SPECIAL INSPECTION
PROVISIONS OF THE
CONSTRUCTION
DOCUMENTS &
APPROVED SUBMITTALS.
ACI 530.1:
ART 1.5PERIODIC
FLOOR & ROOF DECK
WELDS
PERIODIC AWS D1.3
VERIFY f'm & f'aac PRIOR
TO CONSTRUCTION,
EXCEPT WHERE
SPECIFICALLY
EXEMPTED BY CODE
ACI 530.1:
ART 1.4BPERIODIC
VERIFY SLUMP FLOW &
VSI AS DELIVERED TO
THE SITE OF SELF
CONSOLIDATING GROUT
CONTINUOUS
ACI 530.1:
ART 2.6A
PROPORTIONS OF SITE-
PREPARED MORTAR
CONSTRUCTION OF
MORTAR JOINTS
LOCATION OF
REINFORCING,
CONNECTORS, PRE-
STRESSING TENDONS &
ANCHORAGES.
SIZE & LOCATION OF
STRUCTURAL MEMBERS
TYPE, SIZE & LOCATION
OF ANCHORS,
INCLUDING DETAILS OF
ANCHORAGE OF
MASONRY TO OTHER
STRUCTURAL MEMBERS
SPECIFIED SIZE, GRADE
& TYPE OF REINFORCING,
ANCHOR BOLTS, PRE-
STRESSING TENDONS &
ANCHORAGES.
PREPARATION,
CONSTRUCTION &
PROTECTION OF
MASONRY FOR HOT OR
COLD WEATHER
PERIODIC
PERIODIC
PERIODIC
PERIODIC
PERIODIC
PERIODIC
PERIODIC
ACI 530.1:
ART 3.3B
ACI 530.1:
ART 1.5B.1.b.3
ACI 530.1:
ART 3.4 & 3.6A
ACI 530.1:
ART 3.3F
ACI 530.1:
1.2.2(e) & 1.16.1
ACI 530.1:
ART 1.8C & 1.8D
ACI 530.1: 1.15 -
ART 2.4 & 3.4
VERIFY LOCATION, SPACING, HOOK & SPLICE
LENGTH, HOOK & SPLICE LOCATIONS, BEND
DIAMETER, & SUPPORTS OF CONNECTORS,
REINFORCEMENT, & ANCHORAGE
VERIFY USE OF APPROVED GROUT MIXTURE
FOR EACH DELIVERY.
VERIFY SPECIFIED MASONRY COMPRESSIVE
STRENGTH PRIOR TO CONSTRUCTION.
VERIFY USE OF APPROVED DESIGN MIXTURE.
VERIFY COLOR, SIZE, TOLERANCE, LOCATION,
CONNECTORS, AND REINFORCING .
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE002
SPECIAL INSPECTIONS
AUGUST 2018 RID JWV
BID DOCUMENTS
@ AT
Ø DIAMETER
AB ANCHOR BOLT
ADDNL ADDITIONAL
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
APPROX APPROXIMATE
ARCH ARCHITECT(URAL)
BO BOTTOM OF
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BP BEAM POCKET
BPL BASE PLATE
BRCG BRACING
BRG BEARING
BTWN BETWEEN
CF COLD FORM
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY UNIT
CNR CORNER
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CTR CENTER(ED)
DAS DEFORMED ANCHOR STUD
DBA DEFORMED BAR ANCHOR
DBL DOUBLE
DEG DEGREE(S)
DIA, Ø DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DTL DETAIL
DWG DRAWING
DWL DOWEL
(E) EXISTING
EE EACH END
EF EACH FACE
ES EACH SIDE
EW EACH WAY
EA EACH
EL ELEVATION
ELEC ELECTRIC(AL)
EMBED EMBEDMENT
ENG ENGINEER
EQ EQUAL
EXCAV EXCAVATE(TION)
EXP EXPANSION
EXT EXTERIOR
FO FACE OF
FS FAR SIDE
FDN FOUNDATION
FLG FLANGE
FLR FLOOR
FP FIREPROOFING
FRMG FRAMING
FTG FOOTING
GA GAGE, GAUGE
GALV GALVANIZED
GR GRADE
HAS HEAD ANCHOR STUD
HD HOLD DOWN
HDR HEADER
HGR HANGER
HORZ HORIZONTAL
HT HEIGHT
HVY HEAVY
IF INSIDE FACE
INFO INFORMATION
INT INTERIOR
JST JOIST
JT JOINT
KIP 1000LBS
KSI KIP PER SQUARE INCH
LB POUND
LDGR LEDGER
LL LIVE LOAD
LOC LOCATION(S)
LVL LAMINATED VENEER LUMBER
LW LIGHT WEIGHT
MAS MASONRY
MAX MAXIMUM
MECH MECHANICAL
MFD MANUFACTURED
MFR MANUFACTURER
MGMT MANAGEMENT
MIN MINIMUM
MISC MISCELLANEOUS
MTRL MATERIAL
MTL METAL
(N) NEW
NS NEAR SIDE
NTS NOT TO SCALE
NEC'Y NECESSARY
NOM NOMINAL
OC ON CENTER
OF OUTSIDE FACE
OH ON HAND
OPNG OPENING
OSB ORIENTED STRAND BOARD
PC PRECAST CONCRETE
PERP PERPENDICULAR
PL PLATE
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PROJ PROJECT(ION)
PSF POUND PER SQUARE FOOT
PSI POUND PER SQUARE INCH
PT POINT
RO ROUGH OPENING
RC REINFORCED CONCRETE
RE REFERENCE, REFER TO
REINF REINFORCEMENT
REQ'D REQUIRED
REQMTS REQUIREMENTS
RTN RETURN
SOG SLAB ON GRADE
SCHED SCHEDULE
SECT SECTION
SHT SHEET
SHTHG SHEATHING
SIM SIMILAR
SP SPACE
SPCG SPACING
SPEC SPECIFICATION(S)
SQ SQUARE
STD STANDARD
STIFFR STIFFENER
STIFFD STIFFENED
STL STEEL
STRUCT STRUCTURAL
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
T&B TOP AND BOTTOM
THK THICK(NESS)
THRD'D THREADED
TYP TYPICAL
UNO UNLESS OTHERWISE NOTED
URM UNREINFORCED MASONRY
VIF VERIFY IN FIELD
VERT VERTICAL
W/ WITH
W/O WITHOUT
WD WOOD
WWF WELDED WIRE FABRIC
ABBREVIATIONS
X
SE133
LEVEL
FT' - IN"
X
SE141
EXISTING STRUCTURE
MECH UNIT (XXX.Xk = MECH
UNIT OPERATING WEIGHT IN KIPS)
EARTH
CAST-IN-PLACE CONCRETE (NEW)
CAST-IN-PLACE CONCRETE (E)
GROUT
CMU
WAFFLE SLAB (E)
WELDED WIRE REINFORCEMENT
STEEL FLOOR DECK
STEEL ROOF DECK
ROUGHEN SURFACE, INTENTIONALLY
ROUGHEN TO 1/4" AMPLITUDE, UNO.
EDGE OF NEW CONST IN PLAN
EDGE OF HIDDEN CONST IN PLAN
EDGE OF (E) CONST IN PLAN
GRID LINES
SECTION OR
DETAIL CUT
SHEET NUMBER
CALLOUT OR DETAIL
SHEET NUMBER
ELEVATION CALLOUT
DRAWING REVISION
NUMBER
CURRENT REVISION
CLOUD
COLUMN MARK
BRACE FRAME
BEAM SPLICE
KEY NOTE
KEY NOTE FOR JOIST/
SLAB DESIGN
JOIST OR SLAB SPAN
DIRECTION
XX.X
XX
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
GENERAL SYMBOLS LEGEND
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE003
ABBREVIATIONS AND SYMBOLS
AUGUST 2018 RID JWV
BID DOCUMENTS
NPQRSTUVW
11' - 0"
8'
8' - 10"
= CRAWLSPACE ACCESS OPENING
= FOOTING/COLUMN MODIFICATION, SEE SE501
= EDGE OF FOOTING
= 12" ABOVE GROUND SEWER LINE TO REMAIN
(APPROXIMATE LOCATIONS)
= DUCTING TO BE REMOVED
(APPROXIMATE LOCATION)
22' - 4" 25' - 1 1/2" 25' - 1 1/2" 22' - 4" 22' - 4" 25' - 1 1/2" 25' - 1 1/2" 22' - 4"
189' - 10"
/2
/2
1"
SE501
SE501
SIM
SE501
SIM
SE501
SE501
SIM
SE501
SIM
8.1
11.9
Wn V.9 N.1
10" 8" 3"
3" 3"
NOTES:
1. FOUNDATION CONCRETE MUST ACHIEVE 28-DAY STRENGTH BEFORE BEFORE STARTING 3 LEVEL ADDITION.
COLUMN
MARK
EXISTING
FOOTING
SIZE
ULTIMATE
BEARING
PRESSURE
EXISTING
LOAD
(Pu)
NEW
LOAD
(Pu)
DEFICIENCY
8-T 7' 6" x 7' 6" 11200 PSF 584 k
8-U
8-V
10-Q
10-S
10-U
7' 6" x 7' 6"
7' 6" x 7' 6"
8' 6" x 8' 6"
8' 6" x 8' 6"
8' 6" x 8' 6"
11200 PSF
11200 PSF
11200 PSF
11200 PSF
11200 PSF
584 k
584 k
711 k
711 k
711 k 1058 k
701 k
701 k
701 k
1058 k
1058 k
NOMINAL
CAPACITY
(Pn)
630 k
630 k
630 k
810 k
810 k
810 k
71 k
248 k
71 k
71 k
248 k
248 k
FOOTING MODIFICATION DATA TABLE
TN
N
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
KEYPLAN
LAB EXPANSION
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE101
FOUNDATION PLAN
AUGUST 2018 RID JWV
BID DOCUMENTS
REVISIONS DATE
SE101 SCALE: 1/8" = 1'-0"
1 FOUNDATION PLAN
1. EDGE OF EXISTING FOUNDATION WALL.
2. CREATE OPENING IN FOUNDATION WALL TO PROVIDE ACCESS
TO CRAWLSPACE. PROVIDE TEMPORARY SHORING AS
REQUIRED. RETURN WALL TO ORIGINAL CONDITION UPON
COMPLETION, SEE 6-SE501.
T.O. FOOTING ELEV. = -8' - 0"
1/8"=1'-0" 0 16'8'8' 4'
NPQRSTUVW
EXISTING ROOF TO REMAIN
E X
IS
TI
N G
ST
R U
C
TU
R E
T O
R E
M A
IN
189' - 10"
1"
3"
/2
/2
3"
22' - 4" 25' - 1 1/2" 25' - 1 1/2" 22' - 4" 22' - 4" 25' - 1 1/2" 25' - 1 1/2" 22' - 1" 3"
TYP.
1' - 4" 4' - 0" 3' - 8" 4"
3/
8"
BF
-1
BF-2
SE202
BF
-4
SE203BF
-3
SE202
BF-2
SE202
BF-2
SE202
BF-2
SE202
8.1
11.9
Wn V.9
10" 8"
SE505
SE502
SE505
SE505
SE505
N.1
SE505
W x4
W x5 5 2
SE505
SE301
SE505
SE505
SE505
4"
4"
SE301
SE301
SE301
SE203
SE505
TN
N
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
KEYPLAN
LAB EXPANSION
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE131
LEVEL 3 FRAMING PLAN
AUGUST 2018 RID JWV
BID DOCUMENTS
REVISIONS DATE
SE131 SCALE: 1/8" = 1'-0"
1 LEVEL 3 FRAMING PLAN
T.O. CONC ELEV. = 35' - 9"
F.F. ELEV. = 36' - 0"
1. EDGE OF EXISTING STRUCTURE.
2. 8" CMU WALL REINFORCED WITH (1) #5 REBAR AT 32" ON-
CENTER. SEE TYPICAL MASONRY DETAILS ON SE502.
3. EXISTING CONCRETE WAFFLE SLAB.
4. EXISTING 8" CONCRETE SLAB.
1/8"=1'-0"
76k
NOTES:
1. CONTROL JOINTS ARE DIAGRAMMATIC . IF ADJUSTED IN THE
FIELD MAINTAIN A MAXIMUM OF 12'-6" SPACING.
2. ALL TOPPING SLAB CONTROL JOINTS SHALL BE 1" DEPTH. JOINTS
SHALL BE CUT 3 - 8 HOURS AFTER CONCRETE IS PLACED.
3. SLAB PENETRATION LOCATIONS NOT SHOWN. COORDINATE WITH
ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS.
4. EXISTING BUILDING AT LEVEL 3 NOT SHOWN.
CJ
19' - 9" 12' - 4"
/4
8'
9"
REFRIDGERATED
STORAGE,
NO TOPPING
SLAB, VERIFY
DIMS W/ MFR
4" ACCESS
RAMP, COORD
W/ MFR FOR LOC
SE132 (E) CIP SLAB
MAX SLOPE = 1:12
REFRIDG. FLOOR
PER MFR.
TOPPING SLAB
REFRIDGERATOR
WALL BEYOND
LEVEL 3
36' - 0"
(E) WAFFLE SLAB
3" TOPPING
ROUGHEN SURFACE TO
1/4" AMPLITUDE & APPLY
BONDING GROUT COURSE
NOTES:
1. WATER-CEMENT RATIO FOR THE TOPPING SLAB SHALL NOT EXCEED 0.35. PLASTICIZERS
MAY BE USED IF APPROVED BY THE COR.
2. TOPPING SLABS SHALL NOT CONTAIN ENTRAINED AIR UNLESS APPROVED BY THE COR.
3. JUST PRIOR TO TOPPING SLAB PLACEMENT, APPLY A PORTLAND CEMENT BONDING
GROUT COURSE BETWEEN THE OLD AND NEW CONCRETE. BONDING AGENTS MAY USED
IN PLACE OF BONDING GROUT.
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE132
TOPPING SLAB PLAN
AUGUST 2018 RID JWV
BID DOCUMENTS
REVISIONS DATE
SE132 SCALE: 1/8" = 1'-0"
1 LEVEL 3 TOPPING SLAB
FF CONC ELEV. = 36' - 0"
SE132 SCALE: 1" = 1'-0"
3 REFRIGERATED STORAGE RAMP
SE132 SCALE: 1 1/2" = 1'-0"
2 TOPPING SLAB
NPQRSTUVW
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS10
x1
0x 1/2
HSS10
x1
0x 1/2
HSS10
x1
0x 1/2
W12x16 W12x16 W12x16W12x16 W12x16W12x16W12x16 W12x16
W12x16 W12x16 W12x16W12x16 W12x16W12x16W12x16 W12x16
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
9 W 6x
W 6x
W 6x
22' - 4" 25' - 1 1/2" 25' - 1 1/2" 22' - 4" 22' - 4" 25' - 1 1/2" 25' - 1 1/2" 22' - 1" 3"
3"
/2
/2
3"
1"
189' - 10"
W 6x
W 6x
W 6x
9 W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
W 6x
TYP.
E X
IS
TI
U
C
TU
R E
T O
R E
M A
IN
W x2
W x2
BF
-1
BF-2
W x2
W x2
SE202
BF
-11
SE202
BF
-3 1
SE203
SE202
BF-2
SE202
BF-2
SE202
BF-2
SE202
8.1
11.9
Wn V.9 N.1
10" 8"
SE505
SE505
SE505
SE505
SE505
SE505
SE502
4'
0"
HSS8x 8x
3/8
19' - 6" 8"
19' - 6" 8"
1'
0" 3'
0"
SE301
SE503 TYP.
SE203
SE301
SE301
SE301
SE505
SE701
W6x9 TYP.
TN
N
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
KEYPLAN
LAB EXPANSION
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE133
INTERSTITIAL LEVEL FRAMING PLAN
AUGUST 2018 RID JWV
BID DOCUMENTS
REVISIONS DATE
SE133 SCALE: 1/8" = 1'-0"
1 LEVEL 3 INTERSTITIAL FRAMING PLAN
T.O. STEEL ELEV. = 46' - 3"
T.O. CONC ELEV. = 46' - 3"
1. EDGE OF INTERSTITIAL DECK IS PERIMETER BEAM AT
COLUMN LINE.
2. INTERSTITIAL FLOOR DECK: 2" x 20GA NON-COMPOSITE
STEEL DECK WITH 3-3/4" OF LW (110PCF) CONCRETE ABOVE
FLUTE (TOTAL = 5-3/4" THICK). REINFORCE W/ 6x6-W2.1xW2.1.
3. INTERSTITIAL DECK BEAMS SHALL BE AT (4) EQUAL SPACES
BETWEEN COLUMN LINES.
4. INTERSTITIAL BEAMS SHALL BE SPLICED NO FURTHER THAN
12" FROM HANGER SUPPORTS. SEE S504 FOR SPLICE DETAILS.
INTERSTITIAL DECK HANGER: 3/4" ROD SUSPENDS DECK FROM
ROOF BEAMS. HANGERS SHALL BE AT (3) EQUAL SPACES
BETWEEN COLUMN LINES. SEE DETAIL ON 2/SE503.
DUCT PENETRATION LOCATION. NOT ALL INCLUSIVE. SEE
MH131 FOR SIZE AND EXACT LOCATION. DO NOT PENETRATE
AT BEAM LOCATIONS.
NPQRSTUVW
W x5
W x6
W x6
W x6
W x6
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x6
W x6
W x6
W x5
W x1
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x5
W x6
W x6
W x6
W x4
W x4
W x5
W x5
W x4
W x4
W x4
W x4
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
22' - 4" 25' - 1 1/2" 25' - 1 1/2" 22' - 4" 22' - 4" 25' - 1 1/2" 25' - 1 1/2" 22' - 1" 3"
189' - 10"
3"
/2
/2
3"
1"
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x 8x
3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS8x8x3/8
HSS10
x1
0x 1/2
HSS10
x1
0x 1/2
HSS10
x1
0x 1/2
W21x44 W21x44 W21x44 W21x44 W21x44 W21x44 W21x44 W21x44
W16X31 W21x44 W21x44 W21x44 W21x44 W21x44 W21x44 W21x44
W36x210 W36x182W36x170 W36x170
MECH EQ AREA
50 PSF
TYP.
E X
IS
TI
U
C
TU
R E
T O
R E
M A
IN
8" 6'
0"
16' - 9" 8" k k k
W x4
36k
36k
W21x44
W21x44
W16x31 k k
W x5 k k k k k k k
175k 200k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k
56k56k k k k k k k k k k k k k k k k k k k k k
211k 211k 211k211k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k k
210k k k k k k k k
221k
56k 56k 56k 56k56k 56k56k56k 56k 56k 56k 56k k k k k k k k
56k 56k 56k 56k56k 56k56k56k 54k 49k 56k 56k56k56k65k65k
3'
1/
2" 6'
6"
HSS8x 8x
3/8
HSS8x8x3/8
18' - 3" 8"
8.1
11.9
Wn V.9 N.1 k k k k k
W x4
W x4
36k
36k
13k13k
13k13k k
SE504
SE504
SE504
SE505
SE301
SE301
SE301
SE301
4 4
SE504
7' - 8"7' - 8"
SE504
SE502
10" 8"
TN
N
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
KEYPLAN
LAB EXPANSION
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE141
ROOF LEVEL FRAMING PLAN
AUGUST 2018 RID JWV
BID DOCUMENTS
REVISIONS DATE
SE141 SCALE: 1/8" = 1'-0"
1 ROOF LEVEL FRAMING PLAN
T.O. STEEL ELEV. = 54' - 0"
T.O. PAPAPET ELEV. = 56' - 0"
1. EDGE OF BUILDING.
2. 2" EXPANSION JOINT.
3. ROOF DECK: 1-1/2" x 18GA TYPE B GALVANIZED METAL DECK.
FRAMING AT OPENINGS NOT SHOWN, COORDINATE WITH
ARCHITECTURAL AND MECHANICAL, SEE SE503 FOR TYPICAL
FRAMING.
4. ROOF DECK: 1-1/2" x 16GA TYPE B GALVANIZED METAL DECK.
FRAMING AT OPENINGS NOT SHOWN, COORDINATE WITH
ARCHITECTURAL AND MECHANICAL, SEE SE503 FOR TYPICAL
FRAMING.
5. W12X16 AT (4) EQUAL SPACES.
6. ROOF DECK BEAMS SHALL BE AT (4) EQUAL SPACES BETWEEN
COLUMN LINES.
7. MECHANICAL PENTHOUSE FRAMING. VERIFY LOCATION WITH
AE141.
INTERSTITIAL DECK HANGER: 3/4" ROD SUSPENDS DECK FROM
ROOF BEAMS. HANGERS SHALL BE AT (3) EQUAL SPACES
BETWEEN COLUMN LINES. SEE DETAIL ON 2/SE503.
DENOTES FACTORED BEAM REACTION FOR SIZING BEAM AND
COLUMN CONNECTIONS.
# k
ROOF LEVEL
54' - 0"
N P Q R S T U V W
LEVEL 3
36' - 0"
INTERSTITIAL
46' - 3"
SE202
SE202
WnV.9N.1
ROOF LEVEL
54' - 0"
89101112
LEVEL 3
36' - 0"
INTERSTITIAL
46' - 3"
SE202
8.111.9
SE203
ROOF LEVEL
54' - 0"
8 9 10 11 12
LEVEL 3
36' - 0"
INTERSTITIAL
46' - 3"
8.1 11.9
SE203
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE201
BUILDING FRAME ELEVATIONS
AUGUST 2018 RID JWV
BID DOCUMENTS
REVISIONS DATE
SE201 SCALE: 1/8" = 1'-0"
3 PLAN NORTH & SOUTH ELEVATION
SE201 SCALE: 1/8" = 1'-0"
2 PLAN EAST ELEVATION
SE201 SCALE: 1/8" = 1'-0"
1 PLAN WEST ELEVATION
LEVEL 3
36' - 0"
INTERSTITIAL
46' - 3"
SE202
SE202
SE202
NOTES:
1. P = FACTORED AXIAL (TENSION & COMPRESSION) FORCE ALONG MEMBER.
2. SEE PLAN FOR COLUMN LOCATIONS.
3. ALL BRACES ARE ORIENTED LSV, UON.
SE202
8.1
P = 40kHSS 5x5x1/4 HSS 5x5x1/4
P = 35 k
HSS 5x 5x
1/4
P = 45k
P = 40k
HSS 5x5x1/4
22' - 4"
3" 11' - 0 1/2" 11' - 0 1/2"
ROOF LEVEL
54' - 0"
T U
LEVEL 3
36' - 0"
INTERSTITIAL
46' - 3"
25' - 1 1/2"
HSS 5x5x5/16 HSS 5x5x5/16
HSS 5x5x5/16 HSS 5x5x5/16
NOTES:
1. P = FACTORED AXIAL (TENSION & COMPRESSION) FORCE ALONG MEMBER.
2. SEE PLAN FOR COLUMN LOCATIONS.
3. ALL BRACES ARE ORIENTED LSV, UON.
P = 95k P = 95k
P = 60k P = 60k
12' - 6 3/4"
SE202
SE202
SE202
SE202
ROOF LEVEL
54' - 0"
WORK
POINT
3/8" STIFFR PL,
ES OF BM, TYP.
CL BEAM
STL BM,
SEE PLAN
PL 3/4"x12"x4'-4"
CL BRACE
BRACE, SEE BRACE
ELEV THIS SHEET 5/16
5/16
TYP.
1/4 1/4
TYP.
CL BRACE
6"
8"
4"
LEVEL 3
36' - 0"
WORK
POINT
WAFFLE SLAB
CL BRACE
1/4 1/4
TYP.
PL 3/4"x14"x2'-6"
BRACE, SEE BRACE
ELEV THIS SHEET
5/16 5/16
TYP.
CL B
RACE
8" 8"
1/
4"
INTERSTITIAL
46' - 3"
HSS COL
WORK POINT
CL BEAM
SEE HSS SHEAR CONN
ON SHEET SE504
5/16 5/16
TYP.
CL BRACE
BRACE, SEE BRACE
ELEV THIS SHEET
CL
COL
PL 3/4x12x1'-8"
5/16 5/16
TYP.
CLIP CNR 1"
8"
8"
6"
INTERSTITIAL
46' - 3"
CL BRACE
WORK POINT
CL
COL
HSS COL
5/16 5/16
TYP.
BRACE, SEE BRACE
ELEV THIS SHEET
PL 3/4x14x1'-6"
CLIP CNR 1"
BEAM, SEE PLAN
CL BEAM
1/4 1/4
TYP.
8"
8"
7"
ROOF LEVEL
54' - 0"
WORK
POINT
3/8" STIFFR PL,
ES OF BM, TYP.
CL BEAM
STL BM,
SEE PLAN
CL BRACE CL BRACE
5/16 5/16
TYP.
8" 6"
3"
1/4 1/4
TYP.
PL 3/4"x10"x5'-4"
BRACE, SEE BRACE
ELEV THIS SHEET INTERSTITIAL
46' - 3"
HSS COL
WORK POINT
CL BEAM
SEE HSS SHEAR CONN
ON SHEET SE504
CL BRACE
CL
COL
8" 6"
PL 3/4x10x1'-8"
5/16 5/16
TYP.
CLIP CNR 1"
5/16 5/16
TYP.
1/
4"
BRACE, SEE BRACE
ELEV THIS SHEET
INTERSTITIAL
46' - 3"
WORK
POINT
3/8" STIFFR PL,
ES OF BM, TYP.
CL BEAM
STL BM,
SEE PLAN
5/16 5/16
TYP.
CL BRACE CL BRACE
6" 6"
1/4 1/4
TYP.
PL 3/4"x10"x3'-2"
BRACE, SEE BRACE
ELEV THIS SHEET
5"
LEVEL 3
36' - 0"
HSS COL
WORK POINT
SEE BASEPLATES
DETAILS ON SE601
CL BRACE
CL
COL
6" 6"
BRACE, SEE BRACE
ELEV THIS SHEET
PL 3/4x12x1'-0"
5/16 5/16
TYP. CLIP CNR 1"
5/16 5/16
TYP.7 1/2"
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE202
BRACE FRAME ELEVATIONS
AUGUST 2018 RID JWV
BID DOCUMENTS
REVISIONS DATE
SE202 SCALE: 1/4" = 1'-0"
1 BRACE 1 ELEVATION
SE202 SCALE: 1/4" = 1'-0"
2 BRACE 2 ELEVATION
SE202 SCALE: 3/4" = 1'-0"
3 BF1 UPPER-CENTER GUSSET
SE202 SCALE: 3/4" = 1'-0"
5 BF1 LOWER-CENTER GUSSET
SE202 SCALE: 3/4" = 1'-0"
4 BF1 UPPER-CORNER GUSSET
SE202 SCALE: 3/4" = 1'-0"
6 BF1 LOWER-CORNER GUSSET
SE202 SCALE: 3/4" = 1'-0"
7 BF2 UPPER-CENTER GUSSET
SE202 SCALE: 3/4" = 1'-0"
8 BF2 UPPER-CORNER GUSSET
SE202 SCALE: 3/4" = 1'-0"
9 BF2 LOWER-CENTER GUSSET
SE202 SCALE: 3/4" = 1'-0"
10 BF2 LOWER-CORNER GUSSET
8 9
LEVEL 3
36' - 0"
INTERSTITIAL
46' - 3"
8.1
22' - 4"
P = 95k
HSS 5x5x3/8
HSS 5x 5x
1/1
P = 40k
HSS 5x5x5/16 P = 35 k
P = 95kHSS 5x5x3/8
SE203
SE203
SE203
SE203
NOTES:
1. P = FACTORED AXIAL (TENSION & COMPRESSION) FORCE ALONG MEMBER.
2. SEE PLAN FOR COLUMN LOCATIONS.
3. ALL BRACES ARE ORIENTED LSV, UON.
4. EXISTING BUILDING AND COMPONENTS NOT SHOWN FOR CLARITY.
3" 11' - 0 1/2" 11' - 0 1/2"
ROOF LEVEL
54' - 0"
WORK
POINT
3/8" STIFFR PL,
ES OF BM, TYP.
CL BEAM
STL BM,
SEE PLAN
PL 3/4"x12"x4'-4"
CL BRACE
BRACE, SEE BRACE
ELEV THIS SHEET
5/16 5/16
TYP.
1/4 1/4
TYP.
CL BRACE
6"
8"
INTERSTITIAL
46' - 3"
HSS COL
WORK POINT
CL BEAM
SEE HSS SHEAR CONN
ON SHEET SE504
5/16 5/16
TYP.
CL BRACE
BRACE, SEE BRACE
ELEV THIS SHEET
CL
COL
PL 3/4x12x1'-8"
5/16 5/16
TYP.
CLIP CNR 1"
8" 8"
LEVEL 3
36' - 0"
WORK
POINT
WAFFLE SLAB
CL BRACE
5/16 5/16
TYP.
PL 3/4"x14"x2'-6"
BRACE, SEE BRACE
ELEV THIS SHEET
5/16 5/16
TYP.
CL B
RACE
8" 8"
INTERSTITIAL
46' - 3"
CL BRACE
WORK POINT
CL
COL
HSS COL
5/16 5/16
TYP.
BRACE, SEE BRACE
ELEV THIS SHEET
PL 3/4x14x1'-6"
CLIP CNR 1"
BEAM, SEE PLAN
CL BEAM
1/4 1/4
TYP.
8"
8"
ROOF LEVEL
54' - 0"
101112
LEVEL 3
36' - 0"
INTERSTITIAL
46' - 3"
11.9
NOTES:
1. P = FACTORED AXIAL (TENSION & COMPRESSION) FORCE ALONG MEMBER.
2. SEE PLAN FOR COLUMN LOCATIONS.
3. ALL BRACES ARE ORIENTED LSV, UON.
4. EXISTING BUILDING AND COMPONENTS NOT SHOWN FOR CLARITY.
22' - 4" 25' - 1 1/2"
3" 11' - 0 1/2" 11' - 0 1/2" 12' - 6 3/4" 12' - 6 3/4"
P = 35k
P = 45k
HSS 5x5x1/4 P = 40 k
P = 45kHSS 5x5x1/4
HSS 5x5x1/4 HSS 5x5x1/4
HSS 5x5x1/4 HSS 5x5x1/4
SE203
SE203
SE203
SE203
SE203
SE203
SE203
SE203
P = 55k P = 55k
P = 35kP = 45k
HSS 5x 5x
1/4
HSS 5x5x1/4
ROOF LEVEL
54' - 0"
WORK
POINT
3/8" STIFFR PL,
ES OF BM, TYP.
CL BEAM
STL BM,
SEE PLAN
PL 3/4"x10"x4'-6"
8" 6"
CL BRACE
BRACE, SEE BRACE
ELEV THIS SHEET
5/16 5/16
TYP.
1/4 1/4
TYP.
CL BRACE
INTERSTITIAL
46' - 3"
HSS COL
WORK POINT
CL BEAM
SEE HSS SHEAR CONN
ON SHEET SE504
5/16 5/16
TYP.
CL
COL
PL 3/4x11x1'-10"
CLIP CNR 1"
8"
8"
CL BRACE
BRACE, SEE BRACE
ELEV THIS SHEET
5/16 5/16
TYP.
INTERSTITIAL
46' - 3"
WORK POINT
CL
COL
HSS COL
BEAM, SEE PLAN
CL BEAM
PL 3/4x12x1'-5"
CLIP CNR 1"
1/4 1/4
TYP. 8"
6"1'
0"
CL BRACE
5/16 5/16
TYP.
BRACE, SEE BRACE
ELEV THIS SHEET
LEVEL 3
36' - 0"
WORK
POINT
WAFFLE SLAB
5/16 5/16
TYP.
PL 3/4"x13"x2'-6" 8"
8"BRACE, SEE BRACE
ELEV THIS SHEET
5/16 5/16
TYP.
CL BRACECL BRACE
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE203
BRACE FRAME ELEVATIONS
AUGUST 2018 RID JWV
BID DOCUMENTS
REVISIONS DATE
SE203 SCALE: 1/4" = 1'-0"
1 BRACE 3 ELEVATION
SE203 SCALE: 3/4" = 1'-0"
2 BF3 UPPER-CENTER GUSSET
SE203 SCALE: 3/4" = 1'-0"
3 BF3 UPPER-CORNER GUSSET
SE203 SCALE: 3/4" = 1'-0"
4 BF3 LOWER-CENTER GUSSET
SE203 SCALE: 3/4" = 1'-0"
5 BF3 LOWER-CORNER GUSSET
SE203 SCALE: 1/4" = 1'-0"
6 BRACE 4 ELEVATION
SE203 SCALE: 3/4" = 1'-0"
7 BF4 UPPER CENTER GUSSET
SE203 SCALE: 3/4" = 1'-0"
8 BF4 UPPER CORNER GUSSET
SE203 SCALE: 3/4" = 1'-0"
9 BF4 LOWER CORNER GUSSET
SE203 SCALE: 3/4" = 1'-0"
10 BF4 LOWER CENTER GUSSET
DEMO (E) BRICK & SUPPORT
AROUND BEAM LOC.
ROOF
54' - 0"
INTERSTITIAL
46' - 3"
PL 3/4"
HSS COLUMN
DEMO BRICK
VENEER BELOW
LEVEL 4
6'
0"
2" 2"
INTERSTITIAL DECK
5/16
1/2" STIFFENER PL, ES
(E) INTERSTITIAL DECK
W
LEVEL 3
36' - 0"
EXISTING 12" CIP WALL
Wn
10" 8"
W36, SEE PLAN
V.9
W16, SEE PLAN
(E) 8" CIP SLAB
(E) 8" CIP SLAB
(E) 12" CIP WALL
BASEPLATE & ANCHORS,
SEE SE601 FOR DETAILS
DECK BEYOND,
INTERSTITIAL OPNG
5/16 5/16
ES OF BM
DRILL & EPOXY #5 BENT REBAR
W/ STD HOOK W/ 8" EMBED,
LOCS AS SHOWN ON 3/SE505,
DO NOT CUT (E) REBAR
DRILL & EPOXY (4) #5 BENT
REBAR AS SHOWN AT 8" SPCG
W/ 8" EMBED, DO NOT CUT (E)
REBAR, SEE 3/SE505
18"
24"
#4 W/ HOOK EA END,
TYP. (4) LOCS
SE505
SEE DETAIL 9/SE505
HSS COLUMN
6'
0"
4"
LEVEL 3
36' - 0"
(E) 8" CIP SLAB
(E) 8" CIP SLAB
(E) 12" CIP WALL
BASEPLATE & ANCHORS,
SEE SE601 FOR DETAILS
(E) BRICK & SUPPORT TO
REMAIN ABOVE 4TH LEVEL
ROOF
54' - 0"
PL 3/4"
DEMO BRICK
VENEER BELOW
LEVEL 4
5/16
W
EXISTING 12" CIP WALL
Wn
10" 8"
V.9
W16, SEE PLAN
INTERSTITIAL
46' - 3"
INTERSTITIAL DECK
(E) INTERSTITIAL DECK
DRILL & EPOXY #5 BENT REBAR
W/ STD HOOK W/ 8" EMBED,
LOCS AS SHOWN ON 3/SE505,
DO NOT CUT (E) REBAR
DRILL & EPOXY (4) #5 BENT
REBAR AS SHOWN AT 8" SPCG
W/ 8" EMBED, DO NOT CUT (E)
REBAR, SEE 3/SE505
1' - 0"
18"
24"
#4 W/ HOOK EA END,
TYP. (4) LOCS
ROUGHEN SURFACE
SE505
SEE DETAIL 9/SE505
W Wn 10" 8"
7"
BRICK VENEER AND
SUPPORT LEDGE
ASSY TO BE REMOVED
LEVEL 3
36' - 0"
3" TOPPING
3"
(E) CIP COLUMN
(E) WAFFLE SLAB
(E) CIP COLUMN
(E) WAFFLE SLAB
V.9
INTERSTITIAL
46' - 3"
INTERSTITIAL DECK
(E) INTERSTITIAL DECK
ROOF
54' - 0"
(E) BRICK & SUPPORT TO
REMAIN ABOVE 4TH LEVEL
W16, SEE PLAN
4"
SEE DETAIL 9/SE505
DEMO (E) BRICK & SUPPORT
AROUND BEAM LOC.
ROOF
54' - 0"
INTERSTITIAL
46' - 3"
PL 3/4"
HSS COLUMN
DEMO BRICK
VENEER BELOW
LEVEL 4
6'
0"
2" 2"
INTERSTITIAL DECK
5/16
3/8" STIFFENER, ES
(E) INTERSTITIAL DECK
SEE DETAIL 9/SE505
W
LEVEL 3
36' - 0"
EXISTING 12" CIP WALL
Wn
10" 8"
W16, SEE PLAN
V.9
W16, SEE PLAN
(E) 8" CIP SLAB
(E) WAFFLE SLAB,
SEE 1/SE505 FOR
SUPPORT BEAM
BASEPLATE & ANCHORS,
SEE SE601 FOR DETAILS
PROJECT NUMBER
BUILDING
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED DRAWN
DRAWING TITLE
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANT
321 4 5 6 7 8 9 10
DWG. OF
NAME:
FULLY SPRINKLERED
PROJECT DIRECTOR
FULL SIZE DWG: 30x42
PHONE:
EMAIL:
TINA DEBELLA, PE
804.675.5494 Tina.Debella@va.gov
NEW CLINICAL LAB FOR
SURGICAL EXPANSION
RICHMOND, VIRGINIA
652-319
8/
/2
:4 9:
A
M
SE301
WALL SECTIONS AND DETAILS
AUGUST 2018 RID JWV
BID DOCUMENTS
REVISIONS DATE
SE301 SCALE: 3/4" = 1'-0"
3 WALL FRAMING AT 10-Wn
SE301 SCALE: 3/4" = 1'-0"
2 WALL FRAMING AT 11-Wn
SE301 SCALE: 3/4" = 1'-0"
4 WALL FRAMING AT 8-Wn & 9-Wn
SE301 SCALE: 3/4" = 1'-0"
1 WALL FRAMING AT 12-Wn
#4 DOWELS, SEE SECTION
#6 BARS EACH WAY
EDGE OF EXISTING FOOTING,
ROUGHEN SURFACE TO 1/4" AMPLITUDE
NEW FOOTING AREA
SE501
1' - 3" 8' - 6" 1' - 3"
1'
3" 8'
6"
1'
3"
2'
5" 6"
EXISTING…