SPKLR69-2026.xlsx

XLSX spreadsheet 15 KB Posted

Attached to
Fire Suppression Sprinklers at Coatesville VAMC
Solicitation number
36C24426Q0415
Issued by

About this file

This file is a sprinkler system inspection and testing template for Building 69 at a VA Medical Center facility for the year 2026. The document provides a standardized inspection form for recording results of semi-annual sprinkler system testing conducted in accordance with NFPA 25: Standard for the Inspection, Testing and Maintenance of Water-Based Fire Protection Systems, 2023 Edition. The template captures inspection data for multiple zones and locations within Building 69, including the first floor gym, basement mechanical room, and includes sections for recording results of main drain static and residual pressure tests, chamber refill times, flow tests, and tamper valve tests for devices such as post indicator valves (PIV) and OS&Y valves located throughout the mechanical rooms and sprinkler box areas. The form uses a pass/fail rating system (P for passed, F for failed) and documents timed results in minutes and seconds format. Fire Department Connection (FDC) testing is conducted semi-annually in compliance with applicable NFPA standards.

This template directly supports the related federal contract solicitation 36C24426Q0415 for Five-Year Obstruction Inspection of Sprinkler Systems at Coatesville VAMC, which requires contractors to perform comprehensive NFPA 25 compliant internal inspections, obstruction investigations, FDC hydrostatic testing, hydrant flow testing, and sprinkler gauge replacements. The inspection template demonstrates the type of detailed documentation and testing protocols that contractors must maintain and submit as deliverables under the VA contract.

View the file

Other files

File Type Posted
36C24426Q0415 0005.docx DOCX document
36C24426Q0415 0004.docx DOCX document
Site Visit Information 07-9-2026.docx DOCX document
RFI Q and As.docx DOCX document
SPKLR2-2026 Blank.xlsx XLSX spreadsheet
SPKLR38-2026 Blank.xlsx XLSX spreadsheet
SPKLR57-2026 Blank.xlsx XLSX spreadsheet
36C24426Q0415 0003.docx DOCX document
SPKLR139-2026.xlsx XLSX spreadsheet
SPKLR1-2026 Blank.xlsx XLSX spreadsheet
SPKLR39-2026 Blank.xlsx XLSX spreadsheet
SPKLR7-2026 Blank.xlsx XLSX spreadsheet
SPKLR59-2026.xlsx XLSX spreadsheet
SPKLR8-2026 Blank.xlsx XLSX spreadsheet
SPKLR9-2026 Blank.xlsx XLSX spreadsheet
SPKLR4-2026 Blank.xlsx XLSX spreadsheet
SPKLR138-2026 Blank.xlsx XLSX spreadsheet
SPKLR3-2026 Blank.xlsx XLSX spreadsheet
SPKLR6-2026.xlsx XLSX spreadsheet
SPKLR138E-2026 Blank.xlsx XLSX spreadsheet
36C24426Q0415 0002.docx DOCX document
36C24426Q0415 0001.docx DOCX document
SCA 2015-5791 Rev 31.pdf PDF
36C24426Q0415.docx DOCX document
852.219-75 MUST SIGN AND RETURN WITH PROPOSAL.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Building 69

SPRINKLER SYSTEM INSPECTION AND TEST
Building 69
YEAR 20261 ST2ND
Date
Inspector
Main Drain
Static Pressure
Residual Pressure
Chamber Refill Time
Flow Test Results
FloorTest Location6"Zone6"Zone
1ST FL ZONEPT.GYM
BASEMENTMECH. ROOM
Tamper Valve Test Results
DeviceLocation
PIV
OS&YMECH. ROOM
BSMT TAMPERMECH ROOM
1ST FL TAMPERMECH ROOM
SPRINKLER BOX
FDC
TESTED SEMI-ANNUALLY IAW
NFPA 25: STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE
OF WATER BASED FIRE PROTECTION SYSTEMS, 2023 EDITION
ACCEPTABLE TESTING RESULTS
P = PASSED INSPECTION / TEST
F = FAILED INSPECTION / TEST
TIMED RESULTS NOTED IN MINUTES AND SECONDS ( EXAMPLE 1M 30S )