SPKLR139-2026.xlsx
XLSX spreadsheet 14 KB Posted
- Attached to
- Fire Suppression Sprinklers at Coatesville VAMC
- Solicitation number
- 36C24426Q0415
About this file
This file is a pricing template (SPKLR139-2026.xlsx) associated with Solicitation Number 36C24426Q0415 for fire suppression sprinkler services at the Coatesville VA Medical Center. The solicitation requires contractors to perform a five-year obstruction inspection, testing, and maintenance of the facility's sprinkler systems in compliance with NFPA 25 standards and applicable VA policies. The scope of work includes internal pipe assessments, valve inspections, fire department connection (FDC) hydrostatic testing, hydrant flow testing, and replacement of sprinkler gauges. Building 1 requires annual fire pump inspections in the attic, including flow testing at 100% rated capacity, pressure measurements (suction and discharge), comparison of manufacturer's pump curve to current performance, and documentation of voltage and amperage readings.
All work must be completed within 30 calendar days of award and conducted Monday through Friday during administrative hours (8:00 a.m. to 4:30 p.m.), with no work permitted on weekends or Federal holidays. The contractor must employ properly qualified technicians, coordinate all system shutdowns with the VA Point of Contact, adhere to VA safety protocols, and ensure all personnel wear visible company identification badges. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4. Amendment 0003 deleted base and option years for "Program Management" and added RFI Questions and Answers and Sprinkler Inspection Reports to the solicitation documents.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24426Q0415 0005.docx | DOCX document | |
| 36C24426Q0415 0004.docx | DOCX document | |
| Site Visit Information 07-9-2026.docx | DOCX document | |
| RFI Q and As.docx | DOCX document | |
| SPKLR2-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR38-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR57-2026 Blank.xlsx | XLSX spreadsheet | |
| 36C24426Q0415 0003.docx | DOCX document | |
| SPKLR1-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR39-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR7-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR59-2026.xlsx | XLSX spreadsheet | |
| SPKLR8-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR9-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR4-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR138-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR3-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR6-2026.xlsx | XLSX spreadsheet | |
| SPKLR69-2026.xlsx | XLSX spreadsheet | |
| SPKLR138E-2026 Blank.xlsx | XLSX spreadsheet | |
| 36C24426Q0415 0002.docx | DOCX document | |
| 36C24426Q0415 0001.docx | DOCX document | |
| SCA 2015-5791 Rev 31.pdf | ||
| 36C24426Q0415.docx | DOCX document | |
| 852.219-75 MUST SIGN AND RETURN WITH PROPOSAL.pdf |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building 139
| SPRINKLER SYSTEM INSPECTION AND TEST | ||
| Building 139 | ||
| Year 2026 | 1 ST | 2ND |
| Date |
| Inspector |
| Main Drain | |||||
| Static Pressure | |||||
| Residual Pressure | |||||
| Chamber Refill Time | |||||
| Flow Test Results | |||||
| Floor | Test Location | 6" | Zone | 6" | Zone |
| NORTH WEST 0602-0143 | RM. 124 | ||||
| SOUTH EAST 0602-0141 | RM. 124 | ||||
| ATTIC 0602-0145 | N.W.Corner of attic | ||||
| Tamper Valve Test Results | |||||
| Device | Location | ||||
| OS & Y 0602-0140 | RM.141 | ||||
| P.I.V. | N.W. OF BLDG. | ||||
| Northwest Zone 0602-0144 | RM. 124 | ||||
| Southeast Zone 0602-0142 | RM. 124 | ||||
| Attic zone 0602-0146 | Northwest Corner |
| SPRINKLER BOX |
| FDC |
| TESTED SEMI-ANNUALLY IAW NFPA 25: STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE |
| OF WATER BASED FIRE PROTECTION SYSTEMS, 2023 EDITION |
| ACCEPTABLE TESTING RESULTS |
| P = PASSED INSPECTION / TEST |
| F = FAILED INSPECTION / TEST |
| D = DISCONNECTED |
| C = CONTRACTOR TEST |
| TIMED RESULTS NOTED IN MINUTES AND SECONDS ( EXAMPLE 1M 30S ) |