SPKLR57-2026 Blank.xlsx
XLSX spreadsheet 16 KB Posted
- Attached to
- Fire Suppression Sprinklers at Coatesville VAMC
- Solicitation number
- 36C24426Q0415
About this file
This is a blank inspection and testing template for the Building 57 sprinkler system at the Coatesville VA Medical Center for the year 2026. The form documents required inspections and tests to be conducted in accordance with NFPA 25 (2023 edition), the standard for inspection, testing, and maintenance of water-based fire protection systems. The template captures data for flow test results across multiple zones (basement, first floor, second floor, and attic) with designated test locations identified by reference numbers (e.g., 2502-0158, 2502-0170). It includes sections for recording static pressure, residual pressure, chamber refill time, and flow test measurements. The form also documents tamper valve test results for various devices and locations, including the main drain, isolation and shut-off valves, pressure independent valves, hose cabinets, standpipes, and zones throughout the building. Testing is conducted on both a first and second inspection cycle, with results marked as P (passed), F (failed), D (disconnected), or C (contractor test), and timed results noted in minutes and seconds format. The fire department connection (FDC) is tested semi-annually in accordance with NFPA 25 standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24426Q0415 0005.docx | DOCX document | |
| 36C24426Q0415 0004.docx | DOCX document | |
| Site Visit Information 07-9-2026.docx | DOCX document | |
| RFI Q and As.docx | DOCX document | |
| SPKLR2-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR38-2026 Blank.xlsx | XLSX spreadsheet | |
| 36C24426Q0415 0003.docx | DOCX document | |
| SPKLR139-2026.xlsx | XLSX spreadsheet | |
| SPKLR1-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR39-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR7-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR59-2026.xlsx | XLSX spreadsheet | |
| SPKLR8-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR9-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR4-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR138-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR3-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR6-2026.xlsx | XLSX spreadsheet | |
| SPKLR69-2026.xlsx | XLSX spreadsheet | |
| SPKLR138E-2026 Blank.xlsx | XLSX spreadsheet | |
| 36C24426Q0415 0002.docx | DOCX document | |
| 36C24426Q0415 0001.docx | DOCX document | |
| SCA 2015-5791 Rev 31.pdf | ||
| 36C24426Q0415.docx | DOCX document | |
| 852.219-75 MUST SIGN AND RETURN WITH PROPOSAL.pdf |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building 57
| SPRINKLER SYSTEM INSPECTION AND TEST | ||
| Building 57 | ||
| Year 2026 | 1 ST | 2ND |
| Date |
| Inspector |
| Main Drain | |||||
| Static Pressure | |||||
| Residual Pressure | |||||
| Chamber Refill Time | |||||
| Flow Test Results | |||||
| Floor | Test Location | 6" | Zone | 6" | Zone |
| BASEMENT 2502-0158 | BY ELEV. LOBBY | ||||
| FIRST FLOOR 2502-0170 | MAIN ENTRANCE | ||||
| SECOND FLOOR 2502-0178 | RM. 201A | ||||
| ATTIC 2502-0180 | ELEV. ROOM | ||||
| Tamper Valve Test Results | |||||
| Device | Location | ||||
| 6'' Main 2502-0146 | B14 | ||||
| OS & Y | RM. B14 | ||||
| P.I.V. 2502-0150 | N.E. OF BLDG. | ||||
| MAIN RISER 2502-0149 | ELEV. LOBBY | ||||
| BASEMENT ZONE 2502-0154 | BY ELEV.LOBBY | ||||
| NORTH HOSE CAB 2502-0153 | OVER BSMT CAB | ||||
| CENT HOSE CAB | OVER BSMT CAB | ||||
| SOUTH HOSE CAB 2502-0156 | OVER BSMT CAB | ||||
| NORTH STNDPIPE 2502-0152 | BSMT. STAIRS | ||||
| SOUTH STNDPIPE 2502-0155 | BSMT. STAIRS | ||||
| 1ST FL. ZONE 2502-0171 | RM. 100-A | ||||
| 2ND FL. ZONE 2502-0179 | RM. 201A | ||||
| ATTIC 2502-0181 | ELEV. ROOM |
| SPRINKLER BOX |
| FDC |
| TESTED SEMI-ANNUALLY IAW |
| NFPA 25: STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE |
| OF WATER BASED FIRE PROTECTION SYSTEMS, 2023 EDITION |
| ACCEPTABLE TESTING RESULTS |
| P = PASSED INSPECTION / TEST |
| F = FAILED INSPECTION / TEST |
| D = DISCONNECTED |
| C = CONTRACTOR TEST |
| TIMED RESULTS NOTED IN MINUTES AND SECONDS ( EXAMPLE 1M 30S ) |
File details come from the government source that posted it. Updated .