SPKLR138E-2026 Blank.xlsx
XLSX spreadsheet 24 KB Posted
- Attached to
- Fire Suppression Sprinklers at Coatesville VAMC
- Solicitation number
- 36C24426Q0415
About this file
This is a blank inspection and testing template for Building 138E's sprinkler system at the Coatesville VA Medical Center, designed to record semi-annual fire suppression system inspections and maintenance activities for the year 2026. The template documents critical testing parameters required under NFPA 25 (2023 Edition), including main drain static and residual pressure measurements, chamber refill time, and flow test results for the 6-inch zone located in the mechanical room. The form also captures tamper valve test results for three devices: two OS&Y (Outside Screw and Yoke) valves and one 4-inch main riser, all located in Building 138E's mechanical room. The inspection template includes space for recording results for both first and second testing cycles, with results marked as P (Passed), F (Failed), D (Disconnected), or C (Contractor Test), and timed results documented in minutes and seconds format. The sprinkler box fire department connection (FDC) is tested semi-annually in accordance with NFPA 25 standards, with additional sheet tabs available for recording data from other building systems. This template is part of the broader Five-Year Obstruction Inspection of Sprinkler System contract (Solicitation 36C24426Q0415) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4, which requires comprehensive internal pipe assessments, valve inspections, FDC hydrostatic testing, hydrant flow testing, and sprinkler gauge replacements across the Coatesville VAMC facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24426Q0415 0005.docx | DOCX document | |
| 36C24426Q0415 0004.docx | DOCX document | |
| Site Visit Information 07-9-2026.docx | DOCX document | |
| RFI Q and As.docx | DOCX document | |
| SPKLR2-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR38-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR57-2026 Blank.xlsx | XLSX spreadsheet | |
| 36C24426Q0415 0003.docx | DOCX document | |
| SPKLR139-2026.xlsx | XLSX spreadsheet | |
| SPKLR1-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR39-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR7-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR59-2026.xlsx | XLSX spreadsheet | |
| SPKLR8-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR9-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR4-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR138-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR3-2026 Blank.xlsx | XLSX spreadsheet | |
| SPKLR6-2026.xlsx | XLSX spreadsheet | |
| SPKLR69-2026.xlsx | XLSX spreadsheet | |
| 36C24426Q0415 0002.docx | DOCX document | |
| 36C24426Q0415 0001.docx | DOCX document | |
| SCA 2015-5791 Rev 31.pdf | ||
| 36C24426Q0415.docx | DOCX document | |
| 852.219-75 MUST SIGN AND RETURN WITH PROPOSAL.pdf |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building 138
| SPRINKLER SYSTEM INSPECTION AND TEST | ||
| Building 138E | ||
| YEAR 2026 | 1 ST | 2ND |
| Date |
| Inspector |
| Main Drain | |||||
| Static Pressure | |||||
| Residual Pressure | |||||
| Chamber refill time | |||||
| Flow Test Results | |||||
| Floor | Test Location | 6" | Zone | 6" | Zone |
| 138E | Mech. Room | ||||
| Tamper Valve Test Results | |||||
| Device | Location | ||||
| 138E OS&Y #1 | Mech. Room | ||||
| 138E OS&Y #2 | Mech. Room | ||||
| 138E 4'' Main Riser | Mech. Room |
| SPRINKLER BOX |
| FDC |
| TESTED SEMI-ANNUALLY IAW |
| NFPA 25: STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE |
| OF WATER BASED FIRE PROTECTION SYSTEMS, 2023 EDITION |
| ACCEPTABLE TESTING RESULTS |
| P = PASSED INSPECTION / TEST |
| F = FAILED INSPECTION / TEST |
| D = DISCONNECTED |
| C = CONTRACTOR TEST |
| TIMED RESULTS NOTED IN MINUTES AND SECONDS ( EXAMPLE 1M 30S ) |