SSJ_Handrails(s) 8.21_Redacted.pdf

PDF 238 KB Posted

Attached to
Z1DA--646-19-103 UD Reno 6E 48 Hour Observation
Solicitation number
36C24423R0148
Issued by

About this file

This document is a justification for other than full and open competition for a federal contract opportunity issued by the Department of Veterans Affairs. The justification seeks to sole source the procurement of Acrovyn Handrail products for use in construction and renovation projects throughout VA medical centers in Pittsburgh, Pennsylvania. The handrails are a proprietary product that has been standardized across the VA's facilities due to durability, ease of maintenance, and resistance to bacteria, fungi, and chemicals. Using another product would require duplicative maintenance materials and potentially expose patients to pathogens. The solicitation associated with this justification is for a renovation project at the University Drive VA medical center involving construction of a 48-hour observation unit. The construction project will be fully competed as a set-aside for Service-Disabled Veteran-Owned Small Businesses, thereby ensuring fair and reasonable pricing for the sole sourced handrail component.

View the file

Other files

File Type Posted
64619103_Division 21_08312023.pdf PDF
36C24423R0148 0004_1.docx DOCX document
36C24423R0148 0004.pdf PDF
36C24423R0148 0003.pdf PDF
36C24423R0148 0003_1.docx DOCX document
FLOORING_082323.pdf PDF
36C24423R0148 0002_1.docx DOCX document
36C24423R0148 0002.pdf PDF
Sign in sheet_Redacted.pdf PDF
SSJ_Corner Guard(s) 8.21_Redacted.pdf PDF
SSJ_Curtain tracks(s) 8.21_Redacted.pdf PDF
SSJ_Cambria Quartz Countertop(s)8.21_Redacted.pdf PDF
SSJ_Wilsonart Laminate(s) 8.21_Redacted.pdf PDF
SSJ_ASI Lockers(s) 8.21_Redacted.pdf PDF
SSJ_Mapei_Grout(s) 8.21_Redacted.pdf PDF
SSJ_Interface_LVt(s) 8.21_Redacted.pdf PDF
ssj gooseneck faucets_powers assembly(s) 8.21._Redacted.pdf PDF
SSJ_Sherwin Williams_Paint(s) 8.21_Redacted.pdf PDF
SSJ_Daltile Tile_Rittenhouse(s) 8.21_Redacted.pdf PDF
36C24423R0148 0001.pdf PDF
SSJ_Lumicor Wall Panel(s) 8.21_Redacted.pdf PDF
36C24423R0148 0001_1.docx DOCX document
SSJ_Window Shades(s) 8.21_Redacted.pdf PDF
SSJ_DuPont Corian(s) 8.21_Redacted.pdf PDF
SSJ Arjo Patient Lifts JA FY23(s) 8.21._Redacted.pdf PDF
SSJ_Mannington_BioSpec_Vinyl(s) 8.21_Redacted.pdf PDF
SSJ_Stonhard Flooring(s) 8.21_Redacted.pdf PDF
MEDICAL CENTER REQUIREMENTS - PITTSBURGH.pdf PDF
36C24423R0148 8-3-2023 r1.pdf PDF
64619103_IFB_BP2_Specifications_051723.pdf PDF
64619103_IFB_BP2_Drawings_051723.pdf PDF
Wage Determination PA PA20230077 6.30.2023.pdf PDF
EXHIBIT B - Subcontractor Consent and Reference Form 36C24423R0148 .pdf PDF
EXHIBIT E - Past Performance Questionnaire 36C24420R0148.pdf PDF
EXHIBIT D - Sample Transmittal Letter for Past Performance Evaluation Questionnaire 36C24423R148.pdf PDF
36C24423R0148_2.docx DOCX document
EXHIBIT A - Statement of Prior Experience UD Reno 6E 48 Hour Observation.pdf PDF
36C24423R0148 8-3-23.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF VETERANS AFFAIRS

Justification and Approval (J&A) For Other Than Full and Open Competition (>SAT)

Acquisition Plan Action ID: 36C244-23-AP-3927

1. Contracting Activity:

a. Department of Veterans Affairs, VISN 04, VAPHS, University Drive Campus, Pittsburgh, PA 15215

1. Nature and/or Description of the Action Being Processed: Acquisition of proprietary Acrovyn Handrail in Natural Peregrine-1607. Acrovyn is the standard application throughout VAPHS due to the C/S Acrovyn 4000 Model Series has shown to be most durable and simple solution throughout facilities to protect from damage. Acrovyn 4000 Model Series is resistant to certain bacterial & fungal growth (per ASTM G 22-76 & G 21-96) and chemical resistant (per ASTM D 543). The other factors are that wall guards, and corner guards are a large item that must have maintained stock in order to be replaced on a regular basis as space is limited having a standard allows for a quick replacement. It is necessary to maintain a large stock on all wall guards as they must be replaced for the following reasons: damaged walls, water breaks, patch and repairs by our Maintenance and Repair Shops. Any form of deficiency in a flooring, walls and ceilings must be immediately addressed by our M&R Shops due to Safety and Infectious Control standards.

This Sole Source Product is for Acrovyn Handrail P-PASN in Natural Peregrine-1607to be used in this project, which will be approximately

2. Description of Supplies/Services Required to Meet the Agency’s Needs: The VAPHS uses Acrovyn

Handrail throughout all facilities on both the University Drive and Heinz Campuses. Acrovyn has qualities, as noted below, that are key factors in the standardization. This allows for quick replacements to be completed by our M&R with no adverse side effects to our patients. The Crash Rail is used across the campuses are designed with the following performance criteria:

a. Construction: Acrovyn Handrail is

i. Engineered PETG: Extruded material should be high impact Acrovyn 4000 with shadowgrain texture, nominal .078" (1.98mm) thickness. Chemical and stain resistance should be per ASTM D543 standards as established by the manufacturer. Colors to be indicated in the finish schedule from one of manufacturer’s standard color range.

ii. Aluminum: Extruded aluminum should be 6063-T6 alloy, nominal .062" (1.57mm) thick crash rail retainer. Minimum strength and durability properties as specified in ASTM B221.

iii. Stainless Steel: Handrail to be type 304 alloy with #4 satin finish, nominal ¼" (6.35mm) thickness. Cast brackets to be type 304 alloy with #4 satin finish.

iv. Fasteners: All fasteners to be non-corrosive and compatible with aluminum retainers. All necessary fasteners to be supplied by the manufacturer.

b. Styles:

i. Surface mounted

c. Physical Characteristics:

i. Engineered PETG Handrails to be Acrovyn 4000 by Construction Specialties: Surface mounted handrail and crash rail configuration with color matched end caps returning to the wall and mounting brackets spaced as indicated on C/S installation instructions.

Attachment hardware shall be appropriate for wall construction.

1. Model P-RSAN 6 3/8" h (161.9mm) handrail/crash rail configuration consisting of a round stainless-steel handrail and engineered PETG crash rail with matching end caps returning to the wall. Dual cantilevered mounting brackets to be stainless steel;

optional powder coating available in (8) finishes. Select crash rail from one of (64)* Acrovyn solid colors or (18)* Chameleon patterned colorways, which include (16) woodgrains and (2) metals. (*Specifier note: refer to color selectors to determine which colors and patterns are MBDC Cradle to Cradle® Certified Gold or Silver for Acrovyn wall guards.)

Finishes A. General: Comply with NAAMM “Metal Finishes Manual” for recommendations relative to applications and designations of finishes.

PRODUCT PERFORMANCE AND TECHNICAL DATA

i. Installer qualifications: Engage an installer who has no less than 3 years experience in installation of systems similar in complexity to those required for this project.

ii. Manufacturer’s qualifications: Not less than 5 years experience in the production of specified products and a record of successful in-service performance.

iii. Code compliance: Assemblies should conform to all applicable codes including IBC, UBC, SBCCI, BOCA, Life Safety and CA 01350.

iv. Fire performance characteristics: Provide engineered PETG wall protection system components with UL label indicating that they are identical to those tested in accordance with ASTM E84 for class 1 characteristics listed below:

1. Flame spread: 25 or less

2. Smoke developed: 450 or less

v. Impact Strength: Provide assembled wall protection units that have been tested in accordance with the applicable provisions of ASTM F476.

vi. Chemical and stain resistance: Provide wall protection system components with chemical and stain resistance in accordance with ASTM D543.

vii. Color match: Provide wall protection components that are color matched in accordance with the following:

1. Delta Ecmc of no greater than 1.0 using CIELab color space. (Specifier note:

viii. Construction Specialties' colors are matched under cool white fluorescent

ix. lighting and computer controlled within manufacturing tolerances. Color may

x. vary if alternate lighting sources are present).

xi. Single source responsibility: Provide all components of the wall protection system manufactured by the same company to ensure compatibility of color, texture and physical properties.

Delivery, Storage and Handling

i. Deliver materials to the project site in unopened original factory packaging clearly labeled to show manufacturer.

ii. Store materials in original, undamaged packaging in a cool, dry place out of direct sunlight and exposure to the elements. A minimum room temperature of 40°F (4°C) and a maximum of 100°F (38°C) should be maintained.

iii. Material must be stored flat.

Project Conditions

i. Materials must be acclimated in an environment of 65°-75°F (18°-24°C) for at least 24 hours prior to beginning the installation.

ii. Installation areas must be enclosed and weatherproofed before installation commences.

3. Statutory Authority Permitting Restricted Competition:

( X ) Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements

( ) Unusual and Compelling Urgency ( ) Industrial Mobilization, Engineering, Developmental or Research Capability or Expert Services ( ) International Agreement ( ) Authorized or Required by Statute ( ) National Security ( ) Public Interest

4. Demonstration that the Contractor’s Unique Qualifications or Nature of the Acquisition Requires the

Use of the Authority Cited Above (applicability of authority): The acquisition is authorized pursuant to 10 U.S.C. 2304 (c)(1), and is implemented by FAR 6.302-1 (c), Only one responsible source and no other supplies or services will satisfy agency requirements.

5. Description of Efforts Made to ensure that offers are solicited from as many potential sources as deemed practicable: Any action to increase competition for the suppliers of Acrovyn Vinyl 4000 Model series would cause an undue hardship on the VA Pittsburgh Healthcare System. VAPHS has been making a conscious effort to standardize the finishes throughout the restroom, laboratory and clinical areas to make them more resistant to infectious pathogens and easier for the limited custodial staff to maintain.

The installation of material finishes other than Acrovyn would require duplication of maintenance materials and could expose our veteran patient population to dangerous pathogens unnecessarily.

6. Determination by the CO that the Anticipated Cost to the Government will be Fair and

Reasonable: This item is being sole sourced under a larger construction project that will be competed as a 100% Service-Disabled Veteran Owned Small Business (SDVOSB) set aside.

Therefore, competition will be provided on the base contract which will lead to a fair and reasonable price.

7. Description of the Market Research Conducted and the Results, or a Statement of the Reasons

Market Research Was Not Conducted: Further market research was not conducted based on the same content provided in paragraph 6 above.

8. Any Other Facts Supporting the Use of Other than Full and Open Competition: N/A

9. Listing of Sources that Expressed, in Writing, an Interest in the Acquisition: N/A

10. A Statement of the Actions, if any, the Agency May Take to Remove or Overcome any Barriers to

Competition before Making subsequent acquisitions for the supplies or services required: N/A.

11. Requirements Certification: I certify that the requirement outlined in this justification is a Bona Fide

Need of the Department of Veterans Affairs and that the supporting data under my cognizance, which are included in the justification, are accurate and complete to the best of my knowledge and belief.

Name: Rochelle Landowski Date Title: Interior Design Facility: VA Pittsburgh Healthcare System

12. Approvals in accordance with the VHAPM Part 806.3 OFOC SOP:

a. Contracting Officer or Designee’s Certification (required): I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.

Contract Specialist, Construction West Date Network Contracting Office 4

b. One Level Above the Contracting Officer (Required over SAT but not exceeding $750K): I certify the justification meets requirements for other than full and open competition.

Branch Chief, Construction West Date

Network Contracting Office 4

ELIJAH

MCINTOSH

Digitally signed by ELIJAH

MCINTOSH

Date: 2023.08.17 08:40:00 -04'00'

Rochelle E Landowski 657312

Digitally signed by Rochelle E Landowski 657312 Date: 2023.08.17 15:59:03 -04'00'