19-Attachment B- Geo Report - 69692000 Kings Lake Dr Misc Struc 100% Geo Report SS.pdf

PDF 6 MB Posted

Attached to
Big Bend Road from US 41 to Covington Garden Dr.
Solicitation number
IFB-26-00378
Issued by
Hillsborough County, Florida

About this file

This is a Report of Geotechnical Exploration prepared by AREHNA Engineering, Inc. for WSP USA on behalf of Hillsborough County, Florida, documenting subsurface conditions at the Kings Lake Drive and Old Big Bend Road intersection. The report presents geotechnical exploration services conducted under a Continuing Services Agreement dated November 17, 2021, and includes four Standard Penetration Test (SPT) borings performed to depths of 30 to 35 feet at proposed mast arm pole locations. Field exploration was completed on March 5-6, 2024, with an additional boring (MA-01B) performed on November 6, 2025, to accommodate revised pole locations. The report documents soil sampling, laboratory testing including natural moisture content, gradation analysis, and Atterberg Limits tests, along with groundwater level identification. The project involves four miscellaneous structures (mast arm poles) at the intersection, with the report signed and sealed by professional engineers Kirk M. Eastman, P.E. (Registration 50733) and Andrew Sway, Ph.D., P.G., E.I. (PG Registration PG-2508).

Based on subsurface exploration results, the report recommends site-specific geotechnical design parameters for drilled shaft foundations because the structure locations generally fail to meet established FDOT Standard Plans criteria for friction angle of 30 degrees, unit weight of 50 pounds per cubic foot or greater, and N-blow counts greater than 15. Subsurface conditions reveal predominantly fine sand and silty sand layers from 0 to 27 feet, overlying clayey silt and limestone formations at greater depths. Groundwater was encountered at depths of 1.5 to 3.5 feet below existing grades. The report identifies significant construction challenges including potential cave-in of loose sandy silty soils, difficult bentonite/polymer slurry retention, concrete overruns in soft zones, and limestone excavation requiring specialized equipment. Design recommendations include establishing groundwater level at the ground surface for saturated conditions and ensuring shaft embedment does not occur within one shaft diameter above very loose/soft soils with automatic hammer N-values less than 2 blows per foot. The report was revised November 19, 2025, to reflect updated boring data and pole location adjustments for the 90 percent design phase.

View the file

Other files

File Type Posted
Attachment E- 69692000 BigBendWest Drainage Design Documentation Vol. II Final.pdf PDF
21-Attachment B- Geo Report - 69692000 100P Misc Structures 2025-11-20.pdf PDF
Attachment I- Utility Relocation Schedule 69647.000 Spectrum Revised URS 7.13.2026 TR LS.pdf PDF
Attachment B- Geo Report - 69692000 100P Misc Structures 2025-11-20.pdf PDF
Attachment H- Plans- Lighting.pdf PDF
41-Attachment L- CSX Coordination.pdf PDF
Attachment G- FDOT Grant Agreement.pdf PDF
Attachment I- Utility Relocation Schedule CIP 69647.000 Utility Cert Letter 7.15.26.pdf PDF
27-Attachment I- Utility Relocation Schedule 69647.000 100% REVISED - TEC UWS - REV4 7.13.26 TR LS.pdf PDF
13-AFFIDAVIT OF COMPLIANCE - Denying Doing Business with a Foreign Country of Concern 02.26.2026.docx DOCX document
2-Florida Trench Safety Act, Certification and Disclosure Statement.pdf.pdf PDF
43-Attachment M- Work Class Percentage.pdf PDF
34-Attachment I- Utility Relocation Schedule 69647.000 Spectrum Revised URS 7.13.2026 TR LS.pdf PDF
46-Attachment G- FDOT Grant Agreement.pdf PDF
Attachment B- Geo Report - 69692000 PhIV Rdwy Soil Survey Report 2025-11-20.pdf PDF
40-Attachment K- Insurance Requirements.pdf PDF
52-Attachment H- Plans- ITS.pdf PDF
48-Attachment H- Location Map.pdf PDF
Attachment I- Utility Relocation Schedule 69647.000 100% REVISED - TEC UWS - REV4 7.13.26 TR LS.pdf PDF
Attachment H- Location Map.pdf PDF
11-Direct Deposit Authorization Form 5.15.2025.pdf.pdf PDF
AFFIDAVIT OF COMPLIANCE - Denying Doing Business with a Foreign Country of Concern 02.26.2026.docx DOCX document
3-Allowance Authorization Release Form.pdf.pdf PDF
29-Attachment I- Utility Relocation Schedule CIP 69647.000 100% URS PGS7-10-2026 REV 1SignedTR.pdf PDF
Attachment D- Permits - SWFWMD ERP 43024488.004 Approved.pdf PDF
17-Attachment F- 69692000 6050BigBend ROE ChildcareBrandon 10-9-25 Signed.pdf PDF
Agreement - Construction - Stand Alone.docx.pdf PDF
54-Attachment K- CSX Insurance Receipt.pdf PDF
Attachment I- Utility Relocation Schedule 69647.000 BIG BEND US 41 TO COVINGTON FTR URS 071426 TR LS.pdf PDF
39-Attachment J- CSX1036508- Agreement.pdf PDF
Attachment B- Geo Report - 69692000 Kings Lake Dr Misc Struc 100% Geo Report SS.pdf PDF
8-Change Order Form.pdf.pdf PDF
42-Agreement - Construction - Stand Alone.docx.pdf PDF
Attachment E- 69692000 BigBendWest Drainage Design Documentation Vol. I Final SS (1).pdf PDF
14-Attachment D- Permits - SWFWMD ERP 43024488.004 Approved.pdf PDF
23-Attachment E- 69692000 Waterset-Kings Lake Drainage Memo.pdf PDF
Attachment F- 669692000 6089BigBend ROE HomeDepot 10-9-25 signed.pdf PDF
20-Attachment B- Geo Report - 69692000 PhIV Rdwy Soil Survey Report 2025-11-20.pdf PDF
Attachment B- Geo Report - 69692000 Waterset Trail 100% RSS SS.pdf PDF
47-Attachment H- Clear Letters 2.pdf PDF
18-Attachment F- 669692000 BayIndustrial ROE 10-9-25. signed.pdf PDF
30-Attachment I- Utility Relocation Schedule CIP 69647.000 URS Uniti Fiber REV 3 7.10.26 TR LS.pdf PDF
Attachment F- 669692000 BayIndustrial ROE 10-9-25. signed.pdf PDF
Attachment I- Utility Relocation Schedule CIP 69647.000 100% URS PGS7-10-2026 REV 1SignedTR.pdf PDF
36-Bid Bond.doc.doc DOC document
9-Insurance Certificate.doc.doc DOC document
31-Attachment I- Utility Relocation Schedule MCI 69647.000 100% URS WSP-8-26 LS.pdf PDF
Attachment A- Construction Sign 2026.pdf PDF
32-Attachment I- Utility Relocation SchedCIP 69647 000 US 41 to Covington Garden Drive Zayo UWS 71326 TR LS.pdf PDF
1-Drug Free Workplace Form.doc.doc DOC document
Show 40 more

Latest 50 of 89 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REPORT OF GEOTECHNICAL EXPLORATION

100% MISCELLANEOUS STRUCTURES

KINGS LAKE DRIVE AT OLD BIG BEND ROAD INTERSECTION

IMPROVEMENTS

HILLSBOROUGH COUNTY, FLORIDA

CIP 69647000

AREHNA PROJECT NO. B-21-112.02

July 24, 2025

(Revised November 19, 2025)

Prepared For:

WSP USA

5411 Skycenter Drive Suite 650 Tampa, FL 33607

Prepared By:

AREHNA Engineering, Inc.

5012 West Lemon Street Tampa, FL 33609

5012 West Lemon Street Tampa, Florida 33609 Ph 954.417.8412 │ www.arehna.com

July 24, 2025 (Revised November 19, 2024)

Ms. Tamishe Rodriguez, P.E.

WSP USA

5411 Skycenter Drive Suite 650 Tampa, FL 33607

Tamishe.Rodriguez@wsp.com

Subject: Report of Geotechnical Exploration – 100% Miscellaneous Structures Kings Lake Drive at Old Big Bend Road Intersection Improvements Hillsborough County, Florida

CIP 69647000

AREHNA Project B-21-112.02

AREHNA Engineering, Inc. (AREHNA) is pleased to submit this report of our geotechnical exploration for the proposed project. Services were conducted in general accordance with a Continuing Services Agreement dated November 17, 2021, and AREHNA Proposal B-21-112.02 dated July 10, 2023.

This 90% report presents our understanding of the project, outlines our exploratory procedures, documents the field data obtained, and provides geotechnical recommendations pertaining to design and construction of the new mast arm structures. This report has been updated to include new boring data for the revised location of pole 1.

AREHNA appreciates the opportunity to have assisted WSP USA on this project. Should you have any questions with regards to this report, or if we can be of any further assistance, please contact this office.

Best Regards, AREHNA ENGINEERING, INC.

FLORIDA BOARD OF PROFESSIONAL ENGINEERS CERTIFICATE OF AUTHORIZATION NO. 28410

This item has been digitally signed and sealed by:

Andrew Sway, PhD, P.G., E.I. Kirk M. Eastman, P.E.

Project Manager Senior Geotechnical Engineer Florida Registration PG-2508 Florida Registration 50733

On the date adjacent to the seal.

Signature must be verified on any electronic copies.

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02 Hillsborough County, FL ii

TABLE OF CONTENTS

Page

1.0 PROJECT INFORMATION AND SCOPE OF WORK

1.1 Site Description and Project Characteristics

1.2 Scope of Work

2.0 FIELD EXPLORATION AND LABORATORY TESTING

2.1 Field Exploration

2.2 Laboratory Testing

3.0 SUBSURFACE CONDITIONS

3.1 USGS Topographic Data

3.2 USDA Natural Resources Conservation Service Data

3.3 Subsurface Conditions

3.4 Groundwater Conditions

4.0 ENGINEERING EVALUATION AND RECOMMENDATIONS

4.1 Basis Of Evaluation

4.2 Recommended Geotechnical Parameters: Mast Arms

5.0 CONSTRUCTION CONSIDERATIONS

5.1 Construction Considerations For Signal Mast Arm Structures

6.0 ENVIRONMENTAL CLASSIFICATION

7.0 BASIS FOR RECOMMENDATIONS

LIST OF APPENDICES

APPENDIX A

USGS & USGS Vicinity Maps Report of Core Boring Sheets

APPENDIX B

Summary of USDA Soil Survey – Table 1 Summary of Laboratory Test Results – Table 2 Field and Laboratory Test Procedures

APPENDIX C

Recommended Design Soil Parameters for Mast Arm Foundations

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

1 | P a g e

1.0 PROJECT INFORMATION AND SCOPE OF WORK

1.1 SITE DESCRIPTION AND PROJECT CHARACTERISTICS

The project is located at Kings Lake Dr. and Old Big Bend Rd. just to the north of Big Bend Rd. in Hillsborough

County, Florida. Four (4) mast arm poles are proposed at the Old Big Bend Rd. intersection with Kings Lake

Dr. The miscellaneous structure locations were provided by WSP USA on February 14, 2024, and are summarized in Table 1.1 below:

Table 1.1 Miscellaneous Structures Summary

Structure Type

NAD83 Florida West (US ft) Comments

Northing Easting

Old Big Bend Road and Kings Lake Drive intersection

Mast Arm 1257742.47 535886.08 SW quadrant

Mast Arm 1257829.19 535888.41 NW quadrant

Mast Arm 1257823.97 536002.32 NE quadrant

Mast Arm 1257744.4 536010.1 SE quadrant

After the completion of the initial report, the mast arm locations were revised for 90%. The updated locations were received on July 18, 2025, and are summarized in Table 1.2 below:

Table 1.2 Miscellaneous Structures Summary

Structure Type

No.

CL Const. Kings Lake Dr.

Comments Station Offset

Old Big Bend Road and Kings Lake Drive intersection

Mast Arm 15 304+27 43 LT SW quadrant

Mast Arm 12 305+25 44 LT NW quadrant

Mast Arm 13 305+29 63 RT NE quadrant

Mast Arm 14 304+45 72 RT SE quadrant

This report presents our recommendations for the proposed miscellaneous structures including our understanding of the project, a review of existing subsurface information, an outline of our exploratory

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

2 | P a g e procedures, summary of field and laboratory data obtained as well as our recommendations for site preparation, design, and construction. A report addressing the proposed pavement improvements at the subject intersection and trail improvements along Waterset Blvd. is provided under separate cover.

1.2 SCOPE OF WORK

The primary purpose of the field exploration program was to determine the subsurface conditions for use in generating geotechnical design parameters for the planned miscellaneous structures. In this regard, engineering assessments for the following items were formulated:

General location and description of potentially deleterious materials encountered in the borings which may have an impact on the proposed project.

Identification of the existing groundwater levels.

Evaluation of the subsurface soil properties and general recommendations regarding suitability for the proposed improvements.

Provide recommended design soil parameters and geotechnical recommendations for the miscellaneous structures drilled shaft foundation design.

General geotechnical recommendations for the proposed construction.

The following services were performed to achieve the above-outlined objective:

Reviewed published topographic and soils information from the United States

Geological Survey (USGS) and the ‘Soil Survey of Hillsborough County, Florida’ published by the United States Department of Agriculture (USDA) Soil Conservation

Service (SCS).

Obtained a Hillsborough County ROW permit.

Completed a general visual reconnaissance of the site.

Requested utility location services from Sunshine 811.

Provided Maintenance of Traffic (MOT) in accordance with Florida Department of

Transportation (FDOT) Standard Indices.

Performed four (4) Standard Penetration Test (SPT) borings at or near the proposed mast arm locations to depths of 30 to 35 feet. Samples were collected and Standard

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

3 | P a g e

Penetration Test resistances were measured continuously for the top ten feet and at approximate intervals of five feet thereafter. The boreholes were grouted upon completion.

Visually classified and stratified soil samples in the laboratory using the Unified Soil

Classification System (USCS) and conducted a laboratory testing program including natural moisture content, single sieve #200 gradation and Atterberg Limits tests on selected soil samples.

Reported the results of the field exploration and engineering analysis. The results of the subsurface exploration are presented in this report signed and sealed by a professional engineer specializing in geotechnical engineering.

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

4 | P a g e

2.0 FIELD EXPLORATION AND LABORATORY TESTING

2.1 FIELD EXPLORATION

Four (4) SPT borings (MA-01 through MA-04) to depths of 30 to 35 feet were performed on March 5 and 6, 2024. Due to a revision in the pole 15 location in 2025, boring MA-01 was deleted and replaced with boring

MA-01B performed on November 6, 2025 to a depth of 30 feet. The boring locations were established in the field using Global Positioning System (GPS) equipment with an accuracy of ±10 feet based on plan sheets of the proposed pole locations provided by WSP USA. Boring MA-02 and MA-03 were offset approximately 7 feet to the west and 13 feet to the west, respectively, due to conflicts with underground utilities at the proposed pole locations. Borings MA-01B and MA-02 were performed at the proposed pole locations.

Elevations for the borings performed were estimated using topographic data provided by WSP USA. The soil boring profiles in Appendix A are plotted to elevation based on this data.

The SPT borings were performed with the use of a Truck Mounted Drill Rig equipped with an automatic hammer using Bentonite “Mud” drilling procedures. Samples were collected and Standard Penetration

Test resistances were measured continuously for the upper 10 feet and at approximate intervals of 5 feet, thereafter. The upper four feet was manually hand augered to avoid any potential conflict with unmarked underground utilities. The soil sampling was performed in general accordance with ASTM Test Designation

D-1586, entitled “Penetration Test and Split-Barrel Sampling of Soils.” Upon completion of drilling, the borehole was backfilled with cement grout.

Representative samples from the borings were sealed in glass jars, labeled and transferred to AREHNA’S

Tampa office for appropriate classification by a geotechnical professional.

The Report of Core Borings Sheets, which include the SPT boring locations and soil profiles, are provided in

Appendix A.

2.2 LABORATORY TESTING

The soil samples were transported to AREHNA’s soils laboratory and were classified by a Geotechnical

Professional using the Unified Soil Classification System (USCS) in general accordance with the ASTM Test

Designation D-2488. Our laboratory testing program included natural moisture content tests (ASTM D-2974), Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

5 | P a g e single sieve -200 Wash Gradations (ASTM D-1140), and Atterberg Limits (ASTM D-4318). The laboratory test results are summarized on Table 2 in Appendix B and presented on the Report of Core Boring Sheets in

Appendix A.

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

6 | P a g e

3.0 SUBSURFACE CONDITIONS

3.1 USGS TOPOGRAPHIC DATA

The USGS “Riverview, Florida” Quadrangle map was reviewed for topographic information in the vicinity of the project site. The approximate location of this site has been superimposed on a reproduction of the USGS topographic map presented in Appendix A. Based on this review, the pre-development ground surface elevation at the project alignment is approximately +20 to +25 feet, National Geodetic Vertical Datum of 1929

(NGVD 29).

3.2 USDA NATURAL RESOURCES CONSERVATION SERVICE DATA

The United States Department of Agriculture (USDA) Natural Resources ConservaƟon Service (NRCS) soil survey (current Web Soil Survey) for the area is attached in Appendix A. This survey indicates that the soil at the boring locaƟons consists of Myakka fine sand, 0 to 2 percent slopes (Map Unit 29). The depth of the seasonal high water table is given as 0.5 feet below the natural ground surface. The USDA Soil Survey map for the project site is attached in Appendix A. The summary of the USDA soil types is provided on Table 1 in

Appendix B.

3.3 SUBSURFACE CONDITIONS

The subsurface conditions encountered are shown on the Report of Core Boring Sheets in Appendix A. The soil profiles on these sheets should be consulted for a detailed description of the soil conditions encountered at the boring locations. When reviewing the subsurface profiles, it should be understood soil conditions may vary between and away from boring locations.

In general, the following subsurface conditions were encountered:

Depth

(feet)

Elevation

(ft, NAVD 88) Material Description

MA-01B (SW Mast Arm)

0 12 20.1 8.1 Medium-dense fine SAND (SP) and slightly silty fine SAND (SP-SM).

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

7 | P a g e

(feet)

Elevation

(ft, NAVD 88) Material Description

12 22 8.1 -1.9 Loose silty fine SAND (SM)

22 30 -1.9 -9.9 Very soft to firm clayey SILT (MH)

MA-02 (NW Mast Arm)

0 12 19.5 7.5 Loose to medium-dense fine SAND (SP) and slightly silty fine SAND (SP-

SM).

12 27 7.5 -7.5 Loose to very loose silty fine SAND (SM)

27 32 -7.5 -12.5 Firm clayey SILT (MH)

32 35 -12.5 -15.5 Hard LIMESTONE

MA-03 (NE Mast Arm)

0 12 18.9 6.9 Loose fine SAND (SP) and slightly silty fine SAND (SP-SM).

12 27 6.9 -8.1 Loose to very loose silty fine SAND (SM) and clayey silt fine SAND (SM)

27 32 -8.1 -13.1 Stiff clayey SILT (MH)

32 35 -13.1 -16.1 Stiff LIMESTONE

MA-04 (SE Mast Arm)

0 12 19.8 7.8 Loose to medium-dense fine SAND (SP) and slightly silty fine SAND (SP-

SM).

12 27 7.8 -7.2 Very loose to loose slightly silty fine SAND (SP-SM)

27 30 -7.2 -10.2 Medium-dense SILT (ML)

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

8 | P a g e

3.4 GROUNDWATER CONDITIONS

The groundwater level was encountered at approximate depths of 1.5 to 3.5 feet below existing grades in the borings performed.

Fluctuation in groundwater levels should be expected due to seasonal climatic changes, construction activity, rainfall variations, surface water runoff, and other site-specific factors. Since groundwater level variations are anticipated, design drawings and specifications should accommodate such possibilities and construction planning should be based on the assumption that variations will occur. The groundwater level is presented graphically adjacent to the soil profiles on the Report of Core Boring Sheets in Appendix A.

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

9 | P a g e

4.0 ENGINEERING EVALUATION AND RECOMMENDATIONS

4.1 BASIS OF EVALUATION

Our geotechnical evaluation is based upon the field data and has been compared with previous performances of similar structures bearing on and within soil conditions similar to those encountered in this exploration. If the structural information is incorrect or changed, please contact us so that our evaluations

(and subsequent recommendations) can be reviewed.

It is our understanding that drilled shaft foundations will be used for the proposed mast arm structures. In our evaluation for the subject project, we have addressed the following geotechnical design and construction considerations:

Support of the proposed mast arm structures using drilled shaft foundations.

4.2 RECOMMENDED GEOTECHNICAL PARAMETERS: MAST ARMS

We understand that the proposed mast arm poles will be designed by the Structural Engineer based on the

FDOT Standard Index 649-030 (Standard Mast Arm Assemblies) and 649-31 (Mast Arm Assemblies).

According to the FDOT Standard Plans Indices 649-030 and 649-031, the mast arm poles are supported by drilled shaft foundations, which are pre-designed based upon the following soil criteria:

Classification = Cohesionless (Fine Sand) Friction Angle = 30 degrees Unit Weight = 50 pcf or greater (assumed submerged) N-blowcount > 15

"If the established criteria shown above are met, then the foundations for the mast arm assemblies may be designed using the standard drilled shaft design (Index No. 649-030 for mast arm assemblies). If the values do not meet the established criteria, then a special design will be required using the recommended site-specific geotechnical properties. If special designs are needed, it is our understanding that the design of the foundation will be performed by the Structural Engineer utilizing the FDOT approved MathCAD computer program."

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

10 | P a g e

Based on the results of the mast arm borings, the structure locations generally fail to meet one or more of the established criteria and will require a special site-specific design. Recommended soil parameters for the proposed mast arm foundations are provided in Appendix C. The parameters include soil type, soil unit weight, and angle of friction. These parameters are based on our previous experience with projects utilizing similar structures in similar materials, as well as previous laboratory testing on similar materials and correlations with SPT N-values. In addition, the average SPT N-value of the boring (along the length of the shaft) should be used, and we recommend a design groundwater level at the ground surface (saturated condition).

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

11 | P a g e

5.0 CONSTRUCTION CONSIDERATIONS

The following recommendations are based upon our understanding of the project information, as outlined in Section 2.0 of this report, and the data gathered during this subsurface exploration. If revised project information is developed, we should be notified so that our recommendations can be reviewed. The stratification and consistency of the subsurface materials encountered may vary within even short lateral distances; therefore, any subsurface condition encountered during construction or any additional exploration that deviates from that documented in this exploration should be reported to us so that our recommendations can be reviewed.

5.1 CONSTRUCTION CONSIDERATONS FOR SIGNAL MAST ARM STRUCTURES

The drilled shafts for the mast arm structures should be installed in accordance with Florida Department of Transportation (FDOT) Standard Specifications, Design Standards, and contract documents. We recommend the following plan notes on adverse site conditions be included in the plans for the miscellaneous structure drilled shafts.

For borings MA-01B, MA-02, MA-03, and MA-04, the following plan note should be added:

The Contractor should anticipate difficult drilled shaft installation due to the presence of soft to very soft and very loose soils. The presence of difficult soil conditions may occur at varying depths below the existing ground surface. The contractor should anticipate potential cave-in of the sandy silty soils, difficult conditions to retain bentonite/polymer slurry inside the drilled holes due to the very soft soil conditions, and potential overruns of concrete within the very loose/soft zones. This material was encountered in borings MA-01B, MA-02, MA-03, and MA-04 at approximate depths of 22 to 27 feet, 17 to 27 feet, 22 to 27 feet, and 17 to 22 feet, below existing grades, respectively.

For borings MA-02 and MA-03, the following plan note should be added:

The Limestone stratum corresponds to a formation that typically offers high resistance to excavation.

Special equipment and breaking tools may be required to excavate. This material is also difficult to dewater due to its porosity and permeability. The contractor shall take steps to mitigate difficult drilled shaft installation and minimize the vibrations through the use of specialized equipment and/or

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

12 | P a g e procedures. This material was encountered in borings MA-02 and MA-03 at an approximate depth of 32 feet below existing grades.

Existing electric poles are located near (approximately 50 feet) the proposed NW and NE mast arm pole locations. The existing pole foundation should be protected in accordance with Section 7-11.1 of the FDOT

Standard Specifications for Road and Bridge Construction (SSRBC). If the proposed foundations are located within three shaft diameters of existing poles, use of the temporary casing method is recommended in order to protect the existing pole foundations. In addition, the individual capacity of each foundation

(existing pole foundation and new drilled shaft) may be reduced for center to center spacing less than 3 diameters.

Foundations should not be tipped/embedded within one shaft diameter above very loose/soft soils with automatic hammer N-values of less than 2 blows per foot (N < 2 bpf) to reduce the risk of excessive settlement of the shaft and the potential for instability of the shaft bottom during construction.

If the shaft tip elevation is determined to be within one shaft diameter above very loose/soft soils (N-value of less than 2) based on the design calculations only, the shaft should be extended below the very loose/soft soils into denser underlying material. We recommend that we be provided the design shaft tip elevations for review prior to the final plan submittal.

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

13 | P a g e

6.0 ENVIRONMENTAL CLASSIFICATION

Environmental corrosion parameter tests were not performed for the proposed structures. As per the

FDOT Soils & Foundation Handbook, the miscellaneous structures should be designed for the most aggressive conditions.

Report of Geotechnical Exploration- 100% Miscellaneous Structures November 19, 2025 Kings Lake Drive at Old Big Bend Road Intersection Improvements AREHNA Project B-21-112.02

14 | P a g e

7.0 BASIS FOR RECOMMENDATIONS

The evaluations and recommendations submitted in this report are based upon the data obtained from the soil borings performed at the locations indicated. Regardless of the thoroughness of a geotechnical exploration, there is always a possibility that conditions between borings will be different from those at specific boring locations and that conditions will not be as anticipated by the designers or contractors. In addition, the construction process itself may alter soil conditions. AREHNA is not responsible for the conclusions, opinions or recommendations made by others based on the data presented in this report.

The assessment of site environmental conditions or the presence of contaminants in the soil, rock, surface water or groundwater of the site was beyond the scope of this exploration. Any statements in this report regarding odors, staining of soils, or other unusual conditions observed are strictly for the information of

WSP USA and Hillsborough County.

This report was prepared exclusively for WSP USA and Hillsborough County by AREHNA. The quality of information, conclusions and estimates contained herein is consistent with the level of effort involved in

AREHNA’s services and based on: i) information available at the time of preparation, ii) data supplied by outside sources and iii) the assumptions, conditions and qualifications set forth in this report. This report is intended to be used by WSP USA and Hillsborough County only. Any other use of, or reliance on, this report by any third party is at that party’s sole risk.

APPENDIX A

USDA & USGS Vicinity Maps Report of Core Borings Sheets

USDA SOIL SURVEY MAP USGS TOPOGRAPHIC MAP

N

Feet

0 250

N

Feet

0 250

SECTION:

RANGE:

TOWNSHIP:

SECTION:

RANGE:

TOWNSHIP:

REFERENCE: USDA SOIL SURVEY OF HILLSBOROUGH COUNTY, FLORIDA

3/12/2024613767 D:\1-Arehna\Projects\2021\B-21-112.02 - Waterset Trail\RDSSGEO02.dgn1:22:38 PM

DATE DESCRIPTION

REVISIONS

DATE DESCRIPTION

PUBLIC WORKS ADMINISTRATION

601 E. KENNEDY BLVD.

TAMPA, FLORIDA 33602

CIP NO. SHT. NO.

USDA & USGS VICINITY MAPS

TAMPA, FL 33609

5012 W. LEMON STREET

AREHNA ENGINEERING, INC.

P.E. LICENSE NUMBER 50733

KIRK M. EASTMAN, P.E.

APPROXIMATE PROJECT LOCATION APPROXIMATE PROJECT LOCATION

REFERENCE: "RIVERVIEW, FLORIDA" USGS QUADRANGLE MAP

WATERSET TRAIL

69647000

19 E

31 S

19 E

31 S asway Line asway Line

-5

BOR #

DATE

DRILLER

HAMMER AUTOMATIC

RIG

STA.

REF.

OFF.

ELEV.

N

M. SEIBERT

CME-45

HA

HA

HA

WH

MA-02

3/5/2024

LONGITUDE: W 82.3720315

LATITUDE: N 27.793552

PALE YELLOW LIMESTONE

LIGHT BROWN TO VERY PALE BROWN FINE SAND (SP)

BROWN SLIGHTLY SILTY FINE SAND (SP-SM)

BROWN SILTY FINE SAND (SM)

OLIVE YELLOW CLAYEY SILT (MH)

305+27

51 LT

PI=29

LL=66

-200=43

NMC=83

BROWN CLAYEY SILTY FINE SAND (SM)

¡ CONST. KINGS LAKE DR

19.5 FT

E L E

V A

T I O

N

(F

E E

T

N A

V D

E L E

V A

T I O

N

(F

E E

T

N A

V D

-10

-15

-20

-25

-5

-10

-15

-20

-25

ELEVATION -15.5 FT (NAVD 88)

BORING TERMINATED AT

BOR #

DATE

DRILLER

HAMMER AUTOMATIC

RIG

STA.

REF.

OFF.

ELEV.

N

M. SEIBERT

CME-45

HA

HA

MA-01B

304+26

42 LT

¡ CONST. KINGS LAKE DR

11/6/2025

LONGITUDE: W 82.37201

LATITUDE: N 27.79327

LIGHT BROWN FINE SAND (SP)

REDDISH BROWN SLIGHTLY SILTY FINE SAND (SP-SM)

VERY PALE BROWN FINE SAND (SP)

GRAYISH BROWN SILTY FINE SAND (SM)

DARK BROWN SILTY FINE SAND (SM)

OLIVE YELLOW CLAYEY SILT (MH)

20.1 FT

ELEVATION -9.9 FT (NAVD 88)

BORING TERMINATED AT

25 25

304 305 306 307

N

Feet

0 10

MA-02

MA-03

MA-04

O L

D

B I G

B

E N

D

R

D

KINGS LAKE DR

MA-01B

SAND

SILTY SAND

SAFETY HAMMER

MEDIUM DENSE

AUTOMATIC HAMMER

GRANULAR MATERIALS-

SPT N-VALUE

GREATER THAN 24

LESS THAN 3

(BLOWS/FT.)

SPT N-VALUE

(BLOWS/FT.)

GREATER THAN 40

3 to 8

16 to 30

8 to 15

LESS THAN 1

3 to 6

1 to 3

LEGEND

6 to 12

24 to 40

8 to 24

12 to 24

CONSISTENCY

FIRM

SOFT

VERY STIFF

STIFF

SILTS AND CLAYS

VERY SOFT

4 to 8

2 to 4

RELATIVE DENSITY

LOOSE

DENSE

VERY DENSE

(BLOWS/FT.)

SPT N-VALUE

(BLOWS/FT.)

30 to 50

10 to 30

4 to 10

SPT N-VALUE

LESS THAN 2

VERY LOOSE

HARD GREATER THAN 30

LESS THAN 4

GREATER THAN 50

(UNLESS OTHERWISE NOTED).

SPT VALUE FOR 12 INCHES OF PENETRATION

NUMBERS TO THE LEFT OF BORINGS INDICATEN

HA HAND AUGER

SP

GROUP SYMBOL AS DETERMINED BY VISUAL REVIEW

UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D 2488)

APPROXIMATE SPT BORING LOCATION

LIMESTONE

GROUNDWATER TABLE

NMC

-200

NATURAL MOISTURE CONTENT (%)

PLASTICITY INDEX (%)PI

LIQUID LIMIT (%)LL

FINES PASSING THE #200 STANDARD SIEVE (%)

SILT

TYPICALLY OFFERS HIGH RESISTANCE TO EXCAVATION. SPECIAL

EQUIPMENT AND BREAKING TOOLS MAY BE REQUIRED TO EXCAVATE.

THIS MATERIAL IS ALSO DIFFICULT TO DEWATER DUE TO ITS POROSITY

ASPHALT

WH FELL UNDER WEIGHT OF ROD AND HAMMER

NOTES:

1.

2.

THE CONTRACTOR SHOULD ANTICIPATE DIFFICULT DRILLED SHAFT

INSTALLATION DUE TO THE PRESENCE OF SOFT TO VERY SOFT AND

THE LIMESTONE STRATUM CORRESPONDS TO A FORMATION THAT

AND PERMEABILITY. THE CONTRACTOR SHALL TAKE STEPS TO MITIGATE

DIFFICULT DRILLED SHAFT INSTALLATION AND MINIMIZE THE

VIBRATIONS THROUGH THE USE OF SPECIALIZED EQUIPMENT AND/OR

PROCEDURES. THIS MATERIAL WAS ENCOUNTERED IN BORINGS MA-02

EXISTING GRADES.

VERY LOOSE SOILS. THE PRESENCE OF DIFFICULT SOIL CONDITIONS

MAY OCCUR AT VARYING DEPTHS BELOW THE EXISTING GROUND

SURFACE. THE CONTRACTOR SHOULD ANTICIPATE POTENTIAL CAVE-IN

OF THE SANDY SILTY SOILS, DIFFICULT CONDITIONS TO RETAIN

BENTONITE/POLYMER SLURRY INSIDE THE DRILLED HOLES DUE TO THE

VERY SOFT SOIL CONDITIONS, AND POTENTIAL OVERRUNS OF CONCRETE

WITHIN THE VERY LOOSE/SOFT ZONES. THIS MATERIAL WAS

ENCOUNTERED IN BORINGS MA-01B, MA-02, MA-03, AND MA-04 AT

APPROXIMATE DEPTHS OF 22 TO 27 FEET, 17 TO 27 FEET, 22 TO 27

FEET, AND 17 TO 22 FEET, BELOW EXISTING GRADES, RESPECTIVELY.

AND MA-03 AT AN APPROXIMATE DEPTH OF 32 FEET BELOW

11/18/2025613767 D:\1-Arehna\Projects\2021\B-21-112.02 - Waterset Trail\B1BORING01.DGN4:53:54 PM

DATE DESCRIPTION

REVISIONS

DATE DESCRIPTION

REPORT OF CORE BORINGS

PUBLIC WORKS ADMINISTRATION

601 E. KENNEDY BLVD.

TAMPA, FLORIDA 33602 69647000

T H

E

O F

F I

C I

A L

R

C O

D

T

I

S

E E

T

E C

T R

O N

C

G I

T A

L

Y

G N

A L

U

D

L E

G

A

C

BIG BEND RD (US 41) TO COVINGTON GDN DR

TAMPA, FL 33609

5012 W. LEMON STREET

AREHNA ENGINEERING, INC.

P.E. LICENSE NUMBER 50733

KIRK M. EASTMAN, P.E.

BOR #

DATE

DRILLER

HAMMER AUTOMATIC

RIG

STA.

REF.

OFF.

ELEV.

N

M. SEIBERT

CME-45

HA

HA

MA-03

3/5/2024

BOR #

DATE

DRILLER

HAMMER AUTOMATIC

RIG

STA.

REF.

OFF.

ELEV.

N

M. SEIBERT

CME-45

HA

HA

MA-04

3/5/2024

LONGITUDE: W 82.3717197

LATITUDE: N 27.7935374

LONGITUDE: W 82.3716543

LATITUDE: N 27.793319

PALE YELLOW LIMESTONE

OLIVE YELLOW SILT (ML)

LIGHT BROWN FINE SAND (SP)

VERY PALE BROWN FINE SAND (SP)

BROWN FINE SAND WITH ROOTLETS (SP)

BROWN SLIGHTLY SILTY FINE SAND (SP-SM)

PALE BROWN SLIGHTLY SILTY FINE SAND (SP-SM)

GRAYISH BROWN SILTY FINE SAND (SM)

OLIVE YELLOW CLAYEY SILT (MH)

305+24

50 RT

304+45

72 RT

PI=25

LL=64

-200=43

NMC=55

-200=7

NMC=27

PALE BROWN CLAYEY SILTY FINE SAND (SM)

DARK BROWN SLIGHTLY SILTY FINE SAND (SP-SM)

¡ CONST. KINGS LAKE DR

¡ CONST. KINGS LAKE DR

18.9 FT

19.8 FT

-5

E L E

V A

T I O

N

(F

E E

T

N A

V D

-10

-15

-20

-25

-30

E L E

V A

T I O

N

(F

E E

T

N A

V D

-5

-10

-15

-20

-25

-30

ELEVATION -16.1 FT (NAVD 88)

BORING TERMINATED AT

ELEVATION -10.2 FT (NAVD 88)

BORING TERMINATED AT

304 305 306 307

N

Feet

0 10

MA-02

MA-03

MA-04

O L

D

B I G

B

E N

D

R

D

KINGS LAKE DR

MA-01B

SAND

SILTY SAND

SAFETY HAMMER

MEDIUM DENSE

AUTOMATIC HAMMER

GRANULAR MATERIALS-

SPT N-VALUE

GREATER THAN 24

LESS THAN 3

(BLOWS/FT.)

SPT N-VALUE

(BLOWS/FT.)

GREATER THAN 40

3 to 8

16 to 30

8 to 15

LESS THAN 1

3 to 6

1 to 3

LEGEND

6 to 12

24 to 40

8 to 24

12 to 24

CONSISTENCY

FIRM

SOFT

VERY STIFF

STIFF

SILTS AND CLAYS

VERY SOFT

4 to 8

2 to 4

RELATIVE DENSITY

LOOSE

DENSE

VERY DENSE

(BLOWS/FT.)

SPT N-VALUE

(BLOWS/FT.)

30 to 50

10 to 30

4 to 10

SPT N-VALUE

LESS THAN 2

VERY LOOSE

HARD GREATER THAN 30

LESS THAN 4

GREATER THAN 50

(UNLESS OTHERWISE NOTED).

SPT VALUE FOR 12 INCHES OF PENETRATION

NUMBERS TO THE LEFT OF BORINGS INDICATEN

HA HAND AUGER

SP

GROUP SYMBOL AS DETERMINED BY VISUAL REVIEW

UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D 2488)

APPROXIMATE SPT BORING LOCATION

LIMESTONE

GROUNDWATER TABLE

NMC

-200

NATURAL MOISTURE CONTENT (%)

PLASTICITY INDEX (%)PI

LIQUID LIMIT (%)LL

FINES PASSING THE #200 STANDARD SIEVE (%)

SILT

TYPICALLY OFFERS HIGH RESISTANCE TO EXCAVATION. SPECIAL

EQUIPMENT AND BREAKING TOOLS MAY BE REQUIRED TO EXCAVATE.

THIS MATERIAL IS ALSO DIFFICULT TO DEWATER DUE TO ITS POROSITY

ASPHALT

WH FELL UNDER WEIGHT OF ROD AND HAMMER

NOTES:

1.

2.

THE CONTRACTOR SHOULD ANTICIPATE DIFFICULT DRILLED SHAFT

INSTALLATION DUE TO THE PRESENCE OF SOFT TO VERY SOFT AND

THE LIMESTONE STRATUM CORRESPONDS TO A FORMATION THAT

AND PERMEABILITY. THE CONTRACTOR SHALL TAKE STEPS TO MITIGATE

DIFFICULT DRILLED SHAFT INSTALLATION AND MINIMIZE THE

VIBRATIONS THROUGH THE USE OF SPECIALIZED EQUIPMENT AND/OR

PROCEDURES. THIS MATERIAL WAS ENCOUNTERED IN BORINGS MA-02

EXISTING GRADES.

VERY LOOSE SOILS. THE PRESENCE OF DIFFICULT SOIL CONDITIONS

MAY OCCUR AT VARYING DEPTHS BELOW THE EXISTING GROUND

SURFACE. THE CONTRACTOR SHOULD ANTICIPATE POTENTIAL CAVE-IN

OF THE SANDY SILTY SOILS, DIFFICULT CONDITIONS TO RETAIN

BENTONITE/POLYMER SLURRY INSIDE THE DRILLED HOLES DUE TO THE

VERY SOFT SOIL CONDITIONS, AND POTENTIAL OVERRUNS OF CONCRETE

WITHIN THE VERY LOOSE/SOFT ZONES. THIS MATERIAL WAS

ENCOUNTERED IN BORINGS MA-01B, MA-02, MA-03, AND MA-04 AT

APPROXIMATE DEPTHS OF 22 TO 27 FEET, 17 TO 27 FEET, 22 TO 27

FEET, AND 17 TO 22 FEET, BELOW EXISTING GRADES, RESPECTIVELY.

AND MA-03 AT AN APPROXIMATE DEPTH OF 32 FEET BELOW

11/18/2025613767 D:\1-Arehna\Projects\2021\B-21-112.02 - Waterset Trail\B1BORING02.DGN4:54:03 PM

DATE DESCRIPTION

REVISIONS

DATE DESCRIPTION

REPORT OF CORE BORINGS

PUBLIC WORKS ADMINISTRATION

601 E. KENNEDY BLVD.

TAMPA, FLORIDA 33602 69647000

T

F I

C I

C O

E E

T

E C

T R

O N

C

G I

T A

L

Y

G N

A L

D

L E

G

A

C

BIG BEND RD (US 41) TO COVINGTON GDN DR

TAMPA, FL 33609

5012 W. LEMON STREET

AREHNA ENGINEERING, INC.

P.E. LICENSE NUMBER 50733

KIRK M. EASTMAN, P.E.

APPENDIX B

Summary of USDA Soil Survey – Table 1 Summary of Laboratory Test Results – Table 2

Field and Laboratory Test Procedures

(feet)

Duration (months)

Kind Steel Concrete

0 ‐ 6 Fine Sand A‐2‐4,A‐3 SP‐SM, SM 12 ‐ 40

6 ‐ 20 Sand, Fine Sand A‐2‐4,A‐3 SP‐SM, SM 12 ‐ 40

20 ‐ 36 Fine sand, sand A‐2‐4,A‐3 SP, SP‐SM 1 ‐ 12

36 ‐ 80 Fine sand, sand A‐2‐4,A‐3 SP‐SM, SM 12 ‐ 40

TABLE 1

SUMMARY OF USDA SOIL SURVEY

HILLSBOROUGH COUNTY, FLORIDA

CIP NO. 69647000

AREHNA Project No. B‐21‐112.02

Myakka fine sand, 0 to 2 percent slopes (29)

KINGS LAKE DRIVE AT OLD BIG BEND ROAD INTERSECTION IMPROVEMENTS

USDA Soil Type Depth (inches)

USDA Soil Description AASHTO USCS Permeability

(ft/day)

Seasonal High Groundwater Risk of Corrosion

0.5 Jun ‐ Nov Apparent High High

MA-02 23.5 - 25.0 SM 83 43 66 29

MA-03 23.5 - 25.0 SM 55 43 64 25

MA-04 18.5 - 20.0 SP-SM 27 7 - -

AREHNA Project No. B-21-112.02

TABLE 2

SUMMARY OF LABORATORY TEST RESULTS

KINGS LAKE DRIVE AT OLD BIG BEND ROAD INTERSECTION IMPROVEMENTS

HILLSBOROUGH COUNTY, FLORIDA

CIP NO. 69647000

Boring No.

Sample Depth (feet)

USCS

Classification

Natural Moisture Content

Sieve Analysis (% Passing)

#200 LL PI

Atterberg Limits

APPENDIX C

Recommended Design Soil Parameters for Mast Arm Foundations

5280 W Lemon St Tampa, FL 33609

Project Name: Kings Lake Drive at Old Big Bend Road Intersection Improvements, Hillsborough County, FL Project Number: B-21-112.02

Boring No.: MA-01B Boring GSE (ft, NAVD): 19.6 Prepared by/Date: ATS-11/11/25 Checked by/Date: KME-11/14/25

From To

Sand with silt SP-SM 0 2 5 6.2 30 105 42.6

Sand SP 2 4 5 6.2 30 105 42.6

Sand SP 4 6 19 23.6 34 115 52.6

Sand SP 6 8 15 18.6 33 115 52.6

Sand SP 8 12 12 14.9 32 112 49.6

Silty Sand SM 12 17 4 5.0 27 102 39.6

Silty Sand SM 17 22 5 6.2 28 105 42.6

Silt MH 22 27 1 1.2 ----- 101 39.1

Silt MH 27 30 6 7.4 ----- 119 56.9

Version 1.10 (Created By/ Date: ALA/09-18-15 & Checked By/Date: CJR/09-21-15)

Boring No.

Drilled Shaft Length (ft)

Equivalent SPT N (manual hammer), bpf

Equivalent Average Internal Friction Angle, f

(Degrees)

Equivalent Total Soil

Unit Weight, g (pcf)

Equivalent Effective

(Submerged) Soil Unit

Weight, g' (pcf)

Comment

MA-01B 12 14 32 113.4 51 Special Design Required

14 13 31 112.4 50 Special Design Required

16 12 30 112.4 50 Special Design Required

18 11 30 112.4 50 Special Design Required

20 11 30 112.4 50 Special Design Required

25 9 26 111.4 49 Special Design Required

30 8 22 111.4 49 Special Design Required

35 8 22 111.4 49 Special Design Required

Notes:

Mast Arm Structures - Recommended Design Soil Parameters (Cohesionless)

Location (Station & Offset/ Baseline)

Soil Description Modeled as

Depth (ft.)

SPT N

(automatic hammer), bpf

SPT N

(manual hammer), bpf

Internal Friction Angle, f

(Degrees)

Total Soil Unit Weight, g

(pcf)

Effective (Submerged) Soil Unit Weight, g' (pcf)

Mast Arm Structures - Equivalent Soil Parameters Estimation (Cohesionless)

Note: Unless noted below, we recommend the design groundwater level at the ground surface. If existing grades need to be raised, assume the following soil parameters for the new sand fill: Internal Friction Angle of 30 degrees, Total Unit Weight of 105 pcf, and Effective (Submerged) Soil Unit Weight of 42.6 pcf, and SPT of 10 bpf.

See Report of Core Borings

2. Foundations should not be tipped/embedded within one shaft diameter above very loose/soft soils with automatic hammer N-values of less than 2 blows per foot (N < 2 bpf) to reduce the risk of excessive settlement of the shaft and the potential for instability of the shaft bottom during construction.

1. The average soil strength properties meet or exceed the minimum required soil criteria shown on the FDOT Standard Plans Instructions for Index 649-030. However, the foundation embedment depths shown in Standard Plans Index 649-030 are different than the depth evaluated and a special design may be required.

Tampa, FL 33609

Project Name: Kings Lake Drive at Old Big Bend Road Intersection Improvements, Hillsborough County, FL Project Number: B-21-112.02

Boring No.: MA-02 Boring GSE (ft, NAVD): 19.5 Prepared by/Date: ATS-03/06/24 Checked by/Date: KME-03/13/24

From To Sand SP 0 2 5 6.2 30 105 42.6

Sand SP 2 4 5 6.2 30 105 42.6

Sand with silt SP-SM 4 6 5 6.2 30 105 42.6

Sand with silt SP-SM 6 8 7 8.7 30 112 49.6

Sand with silt SP-SM 8 12 9 11.2 31 112 49.6

Silty Sand SM 12 17 5 6.2 28 105 42.6

Silty Sand SM 17 22 2 2.5 27 102 39.6

Silty Sand SM 22 27 0 0.0 26 100 37.6

Silt MH 27 32 4 5.0 ----- 112 49.7

Limestone Limestone 32 35 66 81.8 ----- 140 77.6

Version 1.10 (Created By/ Date: ALA/09‐18‐15 & Checked By/Date: CJR/09‐21‐15)

Boring No. Drilled Shaft Length (ft)

Equivalent SPT N (manual hammer), bpf

Equivalent Average Internal Friction Angle, (Degrees)

Equivalent Total Soil

Unit Weight, (pcf)

Equivalent Effective

(Submerged) Soil Unit

Weight, ' (pcf)

Comment

MA-02 12 8 30 110.4 48 Special Design Required

14 8 30 110.4 48 Special Design Required

16 8 29 110.4 48 Special Design Required

18 7 29 109.4 47 Special Design Required

20 7 29 109.4 47 Special Design Required

25 6 28 109.4 47 Special Design Required

30 5 25 109.4 47 Special Design Required

35 12 22 112.4 50 Special Design Required

Notes:

Mast Arm Structures - Equivalent Soil Parameters Estimation (Cohesionless)

Note: Unless noted below, we recommend the design groundwater level at the ground surface. If existing grades need to be raised, assume the following soil parameters for the new sand fill: Internal Friction Angle of 30 degrees, Total Unit Weight of 105 pcf, and Effective (Submerged) Soil Unit Weight of 42.6 pcf, and SPT of 10 bpf.

See Report of Core Borings

2. Foundations should not be tipped/embedded within one shaft diameter above very loose/soft soils with automatic hammer N-values of less than 2 blows per foot (N < 2 bpf) to reduce the risk of excessive settlement of the shaft and the potential for instability of the shaft bottom during construction.

1. The average soil strength properties meet or exceed the minimum required soil criteria shown on the FDOT Standard Plans Instructions for Index 649-030. However, the foundation embedment depths shown in Standard Plans Index 649-030 are different than the depth evaluated and a special design may be required.

Mast Arm Structures - Recommended Design Soil Parameters (Cohesionless)

Location (Station & Offset/ Baseline)

Soil Description Modeled as Depth

(ft.)

SPT N

(automatic hammer), bpf

SPT N

(manual hammer), bpf

Internal Friction Angle, (Degrees)

Total Soil Unit Weight, (pcf)

Effective (Submerged) Soil Unit Weight, ' (pcf)

Tampa, FL 33609

Project Name: Kings Lake Drive at Old Big Bend Road Intersection Improvements, Hillsborough County, FL Project Number: B-21-112.02

Boring No.: MA-03 Boring GSE (ft, NAVD): 18.9 Prepared by/Date: ATS-03/06/24 Checked by/Date: KME-03/13/24

From To Sand SP 0 2 5 6.2 30 105 42.6

Sand SP 2 4 5 6.2 30 105 42.6

Sand with silt SP-SM 4 6 5 6.2 30 105 42.6

Sand with silt SP-SM 6 8 3 3.7 29 102 39.6

Sand with silt SP-SM 8 12 6 7.4 30 105 42.6

Silty Sand SM 12 17 4 5.0 27 102 39.6

Silty Sand SM 17 22 3 3.7 27 102 39.6

Silty Sand SM 22 27 2 2.5 27 102 39.6

Silt MH 27 32 9 11.2 ----- 130 67.5

Limestone SP 32 35 6 7.4 30 105 42.6

Version 1.10 (Created By/ Date: ALA/09‐18‐15 & Checked By/Date: CJR/09‐21‐15)

Boring No. Drilled Shaft Length (ft)

Equivalent SPT N (manual hammer), bpf

Equivalent Average Internal Friction Angle, (Degrees)

Equivalent Total Soil

Unit Weight, (pcf)

Equivalent Effective

(Submerged) Soil Unit

Weight, ' (pcf)

Comment

MA-03 12 6 30 109.4 47 Special Design Required

14 6 29 109.4 47 Special Design Required

16 6 29 109.4 47 Special Design Required

18 6 29 109.4 47 Special Design Required

20 6 29 109.4 47 Special Design Required

25 5 28 109.4 47 Special Design Required

30 5 25 109.4 47 Special Design Required

35 6 24 109.4 47 Special Design Required

Notes:

Mast Arm Structures - Equivalent Soil Parameters Estimation (Cohesionless)

Note: Unless noted below, we recommend the design groundwater level at the ground surface. If existing grades need to be raised, assume the following soil parameters for the new sand fill: Internal Friction Angle of 30 degrees, Total Unit Weight of 105 pcf, and Effective (Submerged) Soil Unit Weight of 42.6 pcf, and SPT of 10 bpf.

See Report of Core Borings

2. Foundations should not be tipped/embedded within one shaft diameter above very loose/soft soils with automatic hammer N-values of less than 2 blows per foot (N < 2 bpf) to reduce the risk of excessive settlement of the shaft and the potential for instability of the shaft bottom during construction.

1. The average soil strength properties meet or exceed the minimum required soil criteria shown on the FDOT Standard Plans Instructions for Index 649-030. However, the foundation embedment depths shown in Standard Plans Index 649-030 are different than the depth evaluated and a special design may be required.

Mast Arm Structures - Recommended Design Soil Parameters (Cohesionless)

Location (Station & Offset/ Baseline)

Soil Description Modeled as Depth

(ft.)

SPT N

(automatic hammer), bpf

SPT N

(manual hammer), bpf

Internal Friction Angle, (Degrees)

Total Soil Unit Weight, (pcf)

Tampa, FL 33609

Project Name: Kings Lake Drive at Old Big Bend Road Intersection Improvements, Hillsborough County, FL Project Number: B-21-112.02

Boring No.: MA-04 Boring GSE (ft, NAVD): 19.8 Prepared by/Date: ATS-03/12/24 Checked by/Date: KME-03/13/24

From To Sand SP 0 2 5 6.2 30 105 42.6

Sand SP 2 4 5 6.2 30 105 42.6

Sand SP 4 6 11 13.6 31 112 49.6

Sand SP 6 8 7 8.7 30 112 49.6

Sand with silt SP-SM 8 12 7 8.7 30 112 49.6

Sand with silt SP-SM 12 17 4 5.0 29 102 39.6

Sand with silt SP-SM 17 22 2 2.5 29 102 39.6

Sand with silt SP-SM 22 27 4 5.0 29 102 39.6

Silt ML 27 30 9 11.2 27 100 37.6

Version 1.10 (Created By/ Date: ALA/09‐18‐15 & Checked By/Date: CJR/09‐21‐15)

Boring No. Drilled Shaft Length (ft)

Equivalent SPT N (manual hammer), bpf

Equivalent Average Internal Friction Angle, (Degrees)

Equivalent Total Soil

Unit Weight, (pcf)

Equivalent Effective

(Submerged) Soil Unit

Weight, ' (pcf)

Comment

MA-04 12 9 30 110.4 48 Special Design Required

14 8 30 110.4 48 Special Design Required

16 8 30 110.4 48 Special Design Required

18 7 30 109.4 47 Special Design Required

20 7 30 109.4 47 Special Design Required

25 6 30 109.4 47 Special Design Required

30 7 29 109.4 47 Special Design Required

Notes:

Mast Arm Structures - Equivalent Soil Parameters Estimation (Cohesionless)

Note: Unless noted below, we recommend the design groundwater level at the ground surface. If existing grades need to be raised, assume the following soil parameters for the new sand fill: Internal Friction Angle of 30 degrees, Total Unit Weight of 105 pcf, and Effective (Submerged) Soil Unit Weight of 42.6 pcf, and SPT of 10 bpf.

See Report of Core Borings

2. Foundations should not be tipped/embedded within one shaft diameter above very loose/soft soils with automatic hammer N-values of less than 2 blows per foot (N < 2 bpf) to reduce the risk of excessive settlement of the shaft and the potential for instability of the shaft bottom during construction.

1. The average soil strength properties meet or exceed the minimum required soil criteria shown on the FDOT Standard Plans Instructions for Index 649-030. However, the foundation embedment depths shown in Standard Plans Index 649-030 are different than the depth evaluated and a special design may be required.

Mast Arm Structures - Recommended Design Soil Parameters (Cohesionless)

Location (Station & Offset/ Baseline)

Soil Description Modeled as Depth

(ft.)

SPT N

(automatic hammer), bpf

SPT N

(manual hammer), bpf

Internal Friction Angle, (Degrees)

Total Soil Unit Weight, (pcf)

2025-11-19T08:32:03-0500
Kirk M Eastman

File details come from the government source that posted it. Updated .