21-Attachment B- Geo Report - 69692000 100P Misc Structures 2025-11-20.pdf

PDF 2 MB Posted

Attached to
Big Bend Road from US 41 to Covington Garden Dr.
Solicitation number
IFB-26-00378
Issued by
Hillsborough County, Florida

About this file

This geotechnical engineering report was prepared by Tierra, Inc. for WSP USA on behalf of Hillsborough County regarding foundation design recommendations for miscellaneous structures associated with the Big Bend Road widening project (CIP No. 69647000). The report documents subsurface conditions at six Standard Penetration Test (SPT) boring locations across the project corridor, specifically evaluating soil conditions for one overhead truss sign structure at Station 1084+72, two mast arm signal pole structures at the intersection of Big Bend Road (CR 672) and Bay Industrial Drive, and two mast arm signal pole structures at the intersection of Big Bend Road and Kings Lake Drive. The field exploration was conducted in February 2025, with borings advanced to depths ranging from approximately 30 to 45 feet below existing grades to assess foundation suitability for the proposed structures.

The subsurface investigation revealed sandy soils from ground surface to depths of approximately 18 to 28 feet, underlain by clayey sand, silt, and hard silt materials. Groundwater was encountered at depths ranging from the existing ground surface to approximately 6 feet below grade, with potentiometric levels estimated up to +15 feet NGVD 29 (+14.5 feet NAVD 88). Tierra recommends that all miscellaneous structure foundations be designed using the SAND model based on saturated conditions with groundwater at the surface at no additional cost to Hillsborough County. The report identifies significant construction considerations, including cave-in risks due to loose soils and shallow groundwater, potential requirements for temporary casing methods beyond FDOT specifications, and difficult excavation conditions through hard silt materials that may necessitate specialized equipment and non-conventional construction techniques. All recommended soil parameters, including total saturated unit weights of 105 pounds per cubic foot, effective unit weights of 43 pounds per cubic foot, friction angles of 29 degrees, and averaged N-values for each structure location, are provided in the attached tables for use in foundation design calculations.

View the file

Other files

File Type Posted
Attachment E- 69692000 BigBendWest Drainage Design Documentation Vol. II Final.pdf PDF
Attachment I- Utility Relocation Schedule 69647.000 Spectrum Revised URS 7.13.2026 TR LS.pdf PDF
Attachment B- Geo Report - 69692000 100P Misc Structures 2025-11-20.pdf PDF
Attachment H- Plans- Lighting.pdf PDF
41-Attachment L- CSX Coordination.pdf PDF
Attachment G- FDOT Grant Agreement.pdf PDF
Attachment I- Utility Relocation Schedule CIP 69647.000 Utility Cert Letter 7.15.26.pdf PDF
27-Attachment I- Utility Relocation Schedule 69647.000 100% REVISED - TEC UWS - REV4 7.13.26 TR LS.pdf PDF
13-AFFIDAVIT OF COMPLIANCE - Denying Doing Business with a Foreign Country of Concern 02.26.2026.docx DOCX document
2-Florida Trench Safety Act, Certification and Disclosure Statement.pdf.pdf PDF
43-Attachment M- Work Class Percentage.pdf PDF
34-Attachment I- Utility Relocation Schedule 69647.000 Spectrum Revised URS 7.13.2026 TR LS.pdf PDF
46-Attachment G- FDOT Grant Agreement.pdf PDF
Attachment B- Geo Report - 69692000 PhIV Rdwy Soil Survey Report 2025-11-20.pdf PDF
40-Attachment K- Insurance Requirements.pdf PDF
52-Attachment H- Plans- ITS.pdf PDF
48-Attachment H- Location Map.pdf PDF
Attachment I- Utility Relocation Schedule 69647.000 100% REVISED - TEC UWS - REV4 7.13.26 TR LS.pdf PDF
Attachment H- Location Map.pdf PDF
11-Direct Deposit Authorization Form 5.15.2025.pdf.pdf PDF
AFFIDAVIT OF COMPLIANCE - Denying Doing Business with a Foreign Country of Concern 02.26.2026.docx DOCX document
3-Allowance Authorization Release Form.pdf.pdf PDF
29-Attachment I- Utility Relocation Schedule CIP 69647.000 100% URS PGS7-10-2026 REV 1SignedTR.pdf PDF
Attachment D- Permits - SWFWMD ERP 43024488.004 Approved.pdf PDF
17-Attachment F- 69692000 6050BigBend ROE ChildcareBrandon 10-9-25 Signed.pdf PDF
Agreement - Construction - Stand Alone.docx.pdf PDF
54-Attachment K- CSX Insurance Receipt.pdf PDF
Attachment I- Utility Relocation Schedule 69647.000 BIG BEND US 41 TO COVINGTON FTR URS 071426 TR LS.pdf PDF
39-Attachment J- CSX1036508- Agreement.pdf PDF
Attachment B- Geo Report - 69692000 Kings Lake Dr Misc Struc 100% Geo Report SS.pdf PDF
8-Change Order Form.pdf.pdf PDF
42-Agreement - Construction - Stand Alone.docx.pdf PDF
Attachment E- 69692000 BigBendWest Drainage Design Documentation Vol. I Final SS (1).pdf PDF
14-Attachment D- Permits - SWFWMD ERP 43024488.004 Approved.pdf PDF
23-Attachment E- 69692000 Waterset-Kings Lake Drainage Memo.pdf PDF
Attachment F- 669692000 6089BigBend ROE HomeDepot 10-9-25 signed.pdf PDF
20-Attachment B- Geo Report - 69692000 PhIV Rdwy Soil Survey Report 2025-11-20.pdf PDF
Attachment B- Geo Report - 69692000 Waterset Trail 100% RSS SS.pdf PDF
47-Attachment H- Clear Letters 2.pdf PDF
18-Attachment F- 669692000 BayIndustrial ROE 10-9-25. signed.pdf PDF
30-Attachment I- Utility Relocation Schedule CIP 69647.000 URS Uniti Fiber REV 3 7.10.26 TR LS.pdf PDF
Attachment F- 669692000 BayIndustrial ROE 10-9-25. signed.pdf PDF
Attachment I- Utility Relocation Schedule CIP 69647.000 100% URS PGS7-10-2026 REV 1SignedTR.pdf PDF
36-Bid Bond.doc.doc DOC document
9-Insurance Certificate.doc.doc DOC document
31-Attachment I- Utility Relocation Schedule MCI 69647.000 100% URS WSP-8-26 LS.pdf PDF
Attachment A- Construction Sign 2026.pdf PDF
32-Attachment I- Utility Relocation SchedCIP 69647 000 US 41 to Covington Garden Drive Zayo UWS 71326 TR LS.pdf PDF
1-Drug Free Workplace Form.doc.doc DOC document
Attachment E- 69692000 Waterset-Kings Lake Drainage Memo.pdf PDF
Show 40 more

Latest 50 of 89 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Tierra, Inc.

7351 Temple Terrace Highway · Tampa, Florida 33637

(813) 989-1354

November 20, 2025

WSP USA

2202 N. West Shore Blvd., Suite 300 Tampa, Florida 33607

Attn: Danny Carnley, P.E.

Re: Report of Geotechnical Engineering Services

Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida CIP No.: 69647000 Tierra Project No.: 6511-21-076

Mr. Carnley:

Tierra, Inc. (Tierra) has performed a geotechnical study for the miscellaneous structures associated with the above referenced project. This report includes one (1) new overhead truss sign structure proposed at approximate Station 1084+72, CL Const. CR 672, two (2) new mast arm signal pole structures at the intersection of CR 672 and Bay Industrial Drive and two (2) new mast arm signal pole structures at the intersection of CR 672 and Kings Lake Drive. This report presents the findings of our field exploration and our geotechnical engineering recommendations for use in the design of the proposed miscellaneous structure foundations.

Review of Topographic Information

Based on a review of the “Riverview, Florida” USGS quadrangle map, it appears that the ground elevation in the project vicinity is on the order of +5 feet to +35 feet National Geodetic Vertical Datum of 1929 (NGVD 29).

Review of Potentiometric Information

Based on a review of the “Upper Floridan Aquifer Potentiometric Surface” maps published by the USGS, the potentiometric surface elevation in the project vicinity ranges up to approximately +15 feet, NGVD 29 (+14.5 feet, NAVD 88). Artesian conditions were not encountered during the field exploration. The Contractor should be prepared to address and handle potentiometric levels up to +15 feet, NGVD 29 (+14.5 feet, NAVD 88) at no additional cost to Hillsborough County.

Subsurface Investigation

To evaluate the subsurface conditions at the proposed overhead sign and mast arm signal pole locations, Tierra performed six (6) Standard Penetration Test (SPT) borings to depths ranging from approximately 30 to 45 feet below existing grades within close proximity to the proposed foundation locations.

The borings were located in the field by a representative of Tierra using project design information provided by WSP USA (WSP) and our hand-held, non-survey grade Global Positioning System (GPS) equipment with a manufacturer’s reported accuracy of ±10 feet. The boring locations should be considered approximate. If the boring locations become critical to design, Tierra recommends that the boring locations be survey located. The approximate boring locations are provided on the attached Report of Core Borings sheets.

Report of Geotechnical Engineering Services Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida CIP No.: 69647000 Tierra Project No.: 6511-21-076

The SPT borings were performed in general accordance with American Society for Testing and Materials (ASTM) Test Designation D-1586. The initial 4 to 6 feet of the borings were manually advanced to verify clearance of underground utilities. SPT resistance values were then recorded on intervals of 2 feet to a depth of 10 feet and on intervals of 5 feet thereafter to the boring termination depths.

The SPT borings generally encountered sandy soils from the ground surface to depths ranging from approximately 18½ to 28½ feet below grades underlain by clayey sand to silt to the boring termination depths. Detailed soil information is presented on the attached Report of Core Borings sheets.

Groundwater Information

The groundwater table was encountered within the borings at depths ranging from the existing ground surface to approximately 6 feet below existing grades. The encountered groundwater levels are depicted adjacent to the soil profiles on the attached Report of Core Borings sheet.

At some SPT boring locations, groundwater was not apparent prior to the introduction of drilling fluid into the borehole. Groundwater Not Apparent (GNA) is indicated adjacent to these soil profiles.

It should be noted that groundwater levels tend to fluctuate during periods of prolonged drought and extended rainfall and may be affected by man-made influences. A seasonal effect can occur in which higher groundwater levels are normally recorded in rainy seasons.

Geotechnical Considerations and Recommendations

Foundation Design

It is our understanding that the design of the proposed miscellaneous structure foundations will be performed by WSP utilizing the FDOT Mathcad program. The program models the subsurface as a uniform soil type with consistent strength properties; however, the results of the borings indicate different soil types and properties throughout the boring depths. Recommended soil parameters for the proposed miscellaneous structure foundations are provided on the attached Recommended Soil Parameters tables. These parameters include soil type, soil unit weight, and internal angle of friction. We recommend the foundations be designed based on saturated conditions, i.e. the groundwater table at the ground surface.

Tierra recommends that the miscellaneous structure foundations be designed using the SAND model. The torsional resistance calculation for a SAND profile requires input of an average SPT N-value. Tierra’s Recommended Average N-Values for Mathcad tables are provided in the Attachments.

Hillsborough County, Florida CIP No.: 69647000

Foundation Embedment/Length

Tierra has reviewed the design shaft tip elevations for the proposed miscellaneous structures and concurs that the shaft tip elevations are consistent with suitable soils.

Foundation Installation

The proposed miscellaneous structure foundations should be installed in accordance with Hillsborough County Specifications. Based on the subsurface conditions encountered within the borings and the anticipated foundation construction, the following notes have been included on the attached Report of Core Borings sheets:

• The loose/soft soils encountered within the borings coupled with shallow groundwater table levels are prone to cave-in during drilled shaft construction.

• Temporary casing methods for shaft installation beyond what is required in the FDOT Specifications may be required in order to prevent the collapse/sloughing of the sandy and silty soils and/or groundwater intrusion during shaft construction.

• Hard silt was encountered in the borings. This material is considered rock-like.

Excavation into and through this material will be difficult and may require non-conventional construction techniques and the mobilization of specialized equipment.

Variations in the depth and relative density of this material should be anticipated.

Report Limitations

Our services have been performed, our findings obtained and our recommendations prepared in accordance with generally accepted geotechnical engineering principles and practices at the time of this report. Tierra is not responsible for the conclusions, opinions or recommendations made by others based on this data.

The scope of the exploration was intended to evaluate soil conditions within the influence zone of the proposed structure foundations. The analyses and recommendations submitted in this report are based upon the data obtained from the soil boring performed at the locations indicated. If any subsoil variations become evident during the course of this project, a re-evaluation of the recommendations contained in this report will be necessary after we have had an opportunity to observe the characteristics of the condition encountered. The applicability of the report should also be reviewed in the event significant changes occur in the design, nature or location of the proposed structures.

The scope of our services did not include an environmental assessment for determining the presence or absence of wetlands or hazardous or toxic materials in the soil, bedrock, groundwater, or air, on or below or around this site. The scope of our services did not include determination of the potential for sinkhole activity. Any statements in this report or on the boring logs regarding odors, colors, unusual or suspicious items or conditions are strictly for the information of WSP and their consultants for evaluating the design of the project as it relates to the geotechnical aspects discussed herein.

Hillsborough County, Florida CIP No.: 69647000

Tierra appreciates the opportunity to be of service to WSP on this project. If you have any questions or comments regarding this report, please contact our office at your earliest convenience.

Respectfully Submitted, TIERRA, INC.

Kaitlyn C. Waterman, P.E. Kevin H. Scott, P.E.

Geotechnical Engineer Senior Geotechnical Engineer Florida License No. 96615 Florida License No. 65514

Attachments: Report of Core Borings Sheets Recommended Soil Parameters Tables Recommended Average N-Values for Mathcad Tables

CAPITAL PROGRAMS DEPARTMENT

601 E. KENNEDY BLVD.

TAMPA, FLORIDA 33602

SN-1084+70L

SN-1084+70R

-5

-10

-15

-20

-25

-30

-35

N

HA

HA

HA

BOR # SN-1084+70R

STA. 1084+64

REF. BL CR 672

OFF. 84' RT.

ELEV.

DATE 2/26/2025

DRILLER C. VIRGEN

HAMMER AUTOMATIC

RIG D-25

N

HA

HA

HA

50/6

50/5

BOR # SN-1084+70L

STA. 1084+77

REF. BL CR 672

OFF. 41' LT.

ELEV.

DATE 2/26/2025

DRILLER C. VIRGEN

HAMMER AUTOMATIC

RIG D-25

-5

-10

-15

-20

-25

-30

-35

E L E

V A

T I O

N

I N

F

E E

T

N

A V

D

E L E

V A

T I O

N

I N

F

E E

T

N

A V

D

ELEVATION -35.0 FT (NAVD 88)

BORING TERMINATED AT

ELEVATION -34.0 FT (NAVD 88)

BORING TERMINATED AT

10.0 11.0

SAND WITH SILT (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

GRAY TO BROWN CLAYEY SAND (SC)

SAND WITH SILT (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

-200=3

PI=38

LL=90

NMC=59

-200=66

PI=82

LL=135

NMC=110

-200=85

PI=31

LL=62

NMC=43

-200=27

LONGITUDE: W 82.38169

LATITUDE: N 27.79226

LONGITUDE: W 82.38164

LATITUDE: N 27.79261

APPROXIMATE SPT BORING LOCATION

LEGEND

FIELD EXPLORATIONS

GROUNDWATER LEVEL ENCOUNTERED DURING

GNA

THE INTRODUCTION OF DRILLING FLUID.

GROUNDWATER NOT APPARENT DUE TO

SAND WITH SILT (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

GRAY TO BROWN CLAYEY SAND (SC)

12 to 24

6 to 12

24 to 40

8 to 24

(BLOWS/FT.)

(BLOWS/FT.)

GREATER THAN 24

LESS THAN 3

GREATER THAN 40

LESS THAN 1

3 to 6

1 to 3

3 to 8

8 to 15

30 to 50

10 to 30

4 to 10

(BLOWS/FT.)

SPT N-VALUE

(BLOWS/FT.)

GREATER THAN 30

LESS THAN 4

GREATER THAN 50

LESS THAN 2

VERY LOOSE

HARD

VERY STIFF

STIFF

SILTS AND CLAYS

CONSISTENCY

FIRM

SOFT

VERY SOFT

LOOSE

DENSE

VERY DENSE

4 to 8

2 to 4

RELATIVE DENSITY

GRANULAR MATERIALS-

SAFETY HAMMER AUTOMATIC HAMMER

SPT N-VALUE

SPT N-VALUE SPT N-VALUE

15 to 30

MEDIUM DENSE

BORING LOCATION PLAN

Feet

100200

N

J:\6511\2021 Files\6511-21-076 Big Bend Widening\Microstation\Geotech\SPTBSP_West01.dgnbsawaska 11/20/2025 3:31:17 PM Default

P

E N

T B

L L

P

L T

D R

V L

DESCRIPTIONDATE DESCRIPTION DATE

REVISIONS

69647000

SHT. NO.CIP NO.

REPORT OF CORE BORINGS

BIG BEND RD (US 41 TO COVINGTON GDN DR)

T H

E

O F

F I C I A

L

R

E C

O R

D

T

H I S

S

H E

E T

I S

T

H E

E

L E

C T

R O

N I C

F I

I G I T

A L L

Y

S I G

N

A N

D

S

E A

L

U

D E

R

R

U L E

G .0

F .A .C

P.E. LICENSE NUMBER 65514

KEVIN H. SCOTT, P.E.

TIERRA, INC.

7351 TEMPLE TERRACE HIGHWAY

TAMPA, FLORIDA 33637

GRAY TO BROWN SILT (ML/MH)

NATIONAL GEODETIC VERTICAL DATUM OF 1929

NORTH AMERICAN VERTICAL DATUM OF 1988

NON-PLASTIC

PLASTICITY INDEX (%)

LIQUID LIMIT (%)

NATURAL MOISTURE CONTENT (%)

PERCENT PASSING #200 SIEVE

HAND AUGERED TO VERIFY UTILITY CLEARANCE

NUMBER OF BLOWS FOR 4 INCHES OF PENETRATION

(UNLESS OTHERWISE NOTED).

SPT VALUE FOR 12 INCHES OF PENETRATION

NUMBERS TO THE LEFT OF BORINGS INDICATE

FOR CONFIRMATION OF VISUAL REVIEW.

AND LABORATORY TESTING ON SELECTED SAMPLES

GROUP SYMBOL AS DETERMINED BY VISUAL REVIEW

UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D 2487)

NGVD 29

NAVD 88

NP

PI

LL

NMC

-200

HA

50/4

N

SP

RECOMMENDED ENVIRONMENTAL CLASSIFICATION:

CONCRETE: EXTREMELY AGGRESSIVE

STEEL: EXTREMELY AGGRESSIVE

GRAY TO BROWN SILT (ML/MH)

GRAY TO BROWN SILT (ML/MH)

NOTES:

5.

4.

3.

2.

1.

¡ CONST. CR 672

THE COUNTY.

LEVELS UP TO +15 FEET, NGVD 29 (+14.5 FEET, NAVD 88) AT NO ADDITIONAL COST TO

THE CONTRACTOR SHOULD BE PREPARED TO ADDRESS AND HANDLE POTENTIOMETRIC

ARTESIAN CONDITIONS WERE NOT ENCOUNTERED DURING THE FIELD EXPLORATION.

IN THE PROJECT VICINITY RANGES UP TO +15 FEET, NGVD 29 (+14.5 FEET, NAVD 88).

ELEVATION" MAPS PROVIDED BY THE USGS, THE POTENTIOMETRIC SURFACE ELEVATION

BASED ON A REVIEW OF THE "UPPER FLORIDAN AQUIFER POTENTIOMETRIC SURFACE

THIS MATERIAL SHOULD BE ANTICIPATED.

OF SPECIALIZED EQUIPMENT. VARIATIONS IN THE DEPTH AND RELATIVE DENSITY OF

MAY REQUIRE NON-CONVENTIONAL CONSTRUCTION TECHNIQUES AND THE MOBILIZATION

ROCK-LIKE. EXCAVATION INTO AND THROUGH THIS MATERIAL WILL BE DIFFICULT AND

HARD SILT WAS ENCOUNTERED IN THE BORINGS. THIS MATERIAL IS CONSIDERED

INTRUSION DURING SHAFT CONSTRUCTION.

COLLAPSE/SLOUGHING OF THE SANDY AND SILTY SOILS AND/OR GROUNDWATER

IN THE FDOT SPECIFICATIONS MAY BE REQUIRED IN ORDER TO PREVENT THE

TEMPORARY CASING METHODS FOR SHAFT INSTALLATION BEYOND WHAT IS REQUIRED

CONSTRUCTION.

GROUNDWATER TABLE LEVELS ARE PRONE TO CAVE-IN DURING DRILLED SHAFT

THE LOOSE/SOFT SOILS ENCOUNTERED WITHIN THE BORINGS COUPLED WITH SHALLOW

LOCATIONS AND ELEVATIONS SHOULD BE CONSIDERED APPROXIMATE.

FIELD IN CONJUNCTION WITH PROJECT DESIGN FILES PROVIDED BY WSP. THE BORING

LOCATIONS WERE DETERMINED USING THE GPS COORDINATES RECORDED IN THE

ACCURACY OF ± 10 FEET. STATION, OFFSET, AND ELEVATION OF THE BORING

HAND-HELD, NON-SURVEY GRADE GPS EQUIPMENT WITH A MANUFACTURER'S REPORTED

THE BORINGS WERE LOCATED IN THE FIELD BY A REPRESENTATIVE OF TIERRA USING

L

IM

IT

S P

E E

D

L

IM

IT

S P

E E

D

VEHICLES

TURNING

V E

H

IC

L E S

T U

R N

IN

G

V E

H

IC

L E S

T O

Y I E

L D

T U

R N

IN

G

R

IG

H T L

A N E

M U S T

T U

R N R

IG

T

TAMPA, FLORIDA 33602

SG-1087+75L

SG-1089+50R

B

A Y

I N

D U

S T

R I

¡ CONST. CR 672

APPROXIMATE SPT BORING LOCATION

LEGEND

FIELD EXPLORATIONS

GROUNDWATER LEVEL ENCOUNTERED DURING

GNA

THE INTRODUCTION OF DRILLING FLUID.

GROUNDWATER NOT APPARENT DUE TO

12 to 24

6 to 12

24 to 40

8 to 24

(BLOWS/FT.)

(BLOWS/FT.)

GREATER THAN 24

LESS THAN 3

GREATER THAN 40

LESS THAN 1

3 to 6

1 to 3

3 to 8

8 to 15

30 to 50

10 to 30

4 to 10

(BLOWS/FT.)

SPT N-VALUE

(BLOWS/FT.)

GREATER THAN 30

LESS THAN 4

GREATER THAN 50

LESS THAN 2

VERY LOOSE

HARD

VERY STIFF

STIFF

SILTS AND CLAYS

CONSISTENCY

FIRM

SOFT

VERY SOFT

LOOSE

DENSE

VERY DENSE

4 to 8

2 to 4

RELATIVE DENSITY

GRANULAR MATERIALS-

SAFETY HAMMER AUTOMATIC HAMMER

SPT N-VALUE

SPT N-VALUE SPT N-VALUE

15 to 30

MEDIUM DENSE

SAND WITH SILT (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

GRAY TO BROWN CLAYEY SAND (SC)

P.E. LICENSE NUMBER 65514

KEVIN H. SCOTT, P.E.

TIERRA, INC.

7351 TEMPLE TERRACE HIGHWAY

TAMPA, FLORIDA 33637

NOTES:

5.

4.

3.

2.

1.

RECOMMENDED ENVIRONMENTAL CLASSIFICATION:

CONCRETE: EXTREMELY AGGRESSIVE

STEEL: EXTREMELY AGGRESSIVE

NATIONAL GEODETIC VERTICAL DATUM OF 1929

NORTH AMERICAN VERTICAL DATUM OF 1988

NON-PLASTIC

PLASTICITY INDEX (%)

LIQUID LIMIT (%)

NATURAL MOISTURE CONTENT (%)

PERCENT PASSING #200 SIEVE

HAND AUGERED TO VERIFY UTILITY CLEARANCE

NUMBER OF BLOWS FOR 4 INCHES OF PENETRATION

(UNLESS OTHERWISE NOTED).

SPT VALUE FOR 12 INCHES OF PENETRATION

NUMBERS TO THE LEFT OF BORINGS INDICATE

FOR CONFIRMATION OF VISUAL REVIEW.

AND LABORATORY TESTING ON SELECTED SAMPLES

GROUP SYMBOL AS DETERMINED BY VISUAL REVIEW

UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D 2487)

NGVD 29

NAVD 88

NP

PI

LL

NMC

-200

HA

50/4

N

SP

BROWN CLAY (CL/CH)

GRAY TO BROWN SILT (ML/MH)

THE COUNTY.

LEVELS UP TO +15 FEET, NGVD 29 (+14.5 FEET, NAVD 88) AT NO ADDITIONAL COST TO

THE CONTRACTOR SHOULD BE PREPARED TO ADDRESS AND HANDLE POTENTIOMETRIC

ARTESIAN CONDITIONS WERE NOT ENCOUNTERED DURING THE FIELD EXPLORATION.

IN THE PROJECT VICINITY RANGES UP TO +15 FEET, NGVD 29 (+14.5 FEET, NAVD 88).

ELEVATION" MAPS PROVIDED BY THE USGS, THE POTENTIOMETRIC SURFACE ELEVATION

BASED ON A REVIEW OF THE "UPPER FLORIDAN AQUIFER POTENTIOMETRIC SURFACE

THIS MATERIAL SHOULD BE ANTICIPATED.

OF SPECIALIZED EQUIPMENT. VARIATIONS IN THE DEPTH AND RELATIVE DENSITY OF

MAY REQUIRE NON-CONVENTIONAL CONSTRUCTION TECHNIQUES AND THE MOBILIZATION

ROCK-LIKE. EXCAVATION INTO AND THROUGH THIS MATERIAL WILL BE DIFFICULT AND

HARD SILT WAS ENCOUNTERED IN THE BORINGS. THIS MATERIAL IS CONSIDERED

INTRUSION DURING SHAFT CONSTRUCTION.

COLLAPSE/SLOUGHING OF THE SANDY AND SILTY SOILS AND/OR GROUNDWATER

IN THE FDOT SPECIFICATIONS MAY BE REQUIRED IN ORDER TO PREVENT THE

TEMPORARY CASING METHODS FOR SHAFT INSTALLATION BEYOND WHAT IS REQUIRED

CONSTRUCTION.

GROUNDWATER TABLE LEVELS ARE PRONE TO CAVE-IN DURING DRILLED SHAFT

THE LOOSE/SOFT SOILS ENCOUNTERED WITHIN THE BORINGS COUPLED WITH SHALLOW

LOCATIONS AND ELEVATIONS SHOULD BE CONSIDERED APPROXIMATE.

FIELD IN CONJUNCTION WITH PROJECT DESIGN FILES PROVIDED BY WSP. THE BORING

LOCATIONS WERE DETERMINED USING THE GPS COORDINATES RECORDED IN THE

ACCURACY OF ± 10 FEET. STATION, OFFSET, AND ELEVATION OF THE BORING

HAND-HELD, NON-SURVEY GRADE GPS EQUIPMENT WITH A MANUFACTURER'S REPORTED

THE BORINGS WERE LOCATED IN THE FIELD BY A REPRESENTATIVE OF TIERRA USING

-5

-10

-15

-20

-25

N

HA

HA

HA

50/3

BOR # SG-1087+75L

STA. 1087+58

REF.

OFF. 76' LT.

ELEV. 12.2

DATE 2/25/2025

DRILLER C. VIRGEN

HAMMER AUTOMATIC

RIG D-25

N

HA

HA

BOR # SG-1089+50R

STA. 1089+47

REF.

OFF. 68' RT.

ELEV. 7.7

DATE 2/21/2025

DRILLER R. SCRUGGS

HAMMER AUTOMATIC

RIG D-25

£ CR 672 £ CR 672

E L E

V A

T I O

N

I N

F

E E

T

N

A V

D

SAND WITH SILT (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

SAND WITH SILT (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

GRAY TO BROWN CLAYEY SAND (SC)

ELEVATION -17.8 FT (NAVD 88)

BORING TERMINATED AT

ELEVATION -22.3 FT (NAVD 88)

BORING TERMINATED AT

-5

-10

-15

-20

-25

E L E

V A

T I O

N

I N

F

E E

T

N

A V

D

LONGITUDE: W 82.38077

LATITUDE: N 27.79269

LONGITUDE: W 82.38019

LATITUDE: N 27.79228

PI=56

LL=106

NMC=74

-200=53

-200=8

OC=5.0

NMC=32

-200=11

PI=51

LL=83

NMC=77

-200=51

GRAY TO BROWN SILT (ML/MH)

SAND WITH SILT WITH TRACE ORGANICS (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

BROWN CLAY (CL/CH)

J:\6511\2021 Files\6511-21-076 Big Bend Widening\Microstation\Geotech\SPTBSG_West01.dgnbsawaska 11/20/2025 3:33:13 PM Default

P

E N

T B

L L

P

L T

D R

V

69647000

(1 OF 2)

BIG BEND RD (US 41 TO COVINGTON GDN DR)

T

F I C I A

L

R

E C

O

T

H I S

S

H E

E T

I S

T

H E

E

L E

C T

R O

N I C

F I

G I T

A L L

Y

S I G

N

D

S

E A

L

D E

R

R

U L E

G .0

F .A .C

BORING LOCATION PLAN

Feet

100200

TAMPA, FLORIDA 33602

SG-1115+30L

SG-1117+30R

¡ CONST. CR 672

K I N

G S

L

A K

APPROXIMATE SPT BORING LOCATION

LEGEND

FIELD EXPLORATIONS

GROUNDWATER LEVEL ENCOUNTERED DURING

GNA

THE INTRODUCTION OF DRILLING FLUID.

GROUNDWATER NOT APPARENT DUE TO

12 to 24

6 to 12

24 to 40

8 to 24

(BLOWS/FT.)

(BLOWS/FT.)

GREATER THAN 24

LESS THAN 3

GREATER THAN 40

LESS THAN 1

3 to 6

1 to 3

3 to 8

8 to 15

30 to 50

10 to 30

4 to 10

(BLOWS/FT.)

SPT N-VALUE

(BLOWS/FT.)

GREATER THAN 30

LESS THAN 4

GREATER THAN 50

LESS THAN 2

VERY LOOSE

HARD

VERY STIFF

STIFF

SILTS AND CLAYS

CONSISTENCY

FIRM

SOFT

VERY SOFT

LOOSE

DENSE

VERY DENSE

4 to 8

2 to 4

RELATIVE DENSITY

GRANULAR MATERIALS-

SAFETY HAMMER AUTOMATIC HAMMER

SPT N-VALUE

SPT N-VALUE SPT N-VALUE

15 to 30

MEDIUM DENSE

SAND WITH SILT (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

GRAY TO BROWN CLAYEY SAND (SC)

P.E. LICENSE NUMBER 65514

KEVIN H. SCOTT, P.E.

TIERRA, INC.

7351 TEMPLE TERRACE HIGHWAY

TAMPA, FLORIDA 33637

NOTES:

5.

4.

3.

2.

1.

RECOMMENDED ENVIRONMENTAL CLASSIFICATION:

CONCRETE: EXTREMELY AGGRESSIVE

STEEL: EXTREMELY AGGRESSIVE

NATIONAL GEODETIC VERTICAL DATUM OF 1929

NORTH AMERICAN VERTICAL DATUM OF 1988

NON-PLASTIC

PLASTICITY INDEX (%)

LIQUID LIMIT (%)

NATURAL MOISTURE CONTENT (%)

PERCENT PASSING #200 SIEVE

HAND AUGERED TO VERIFY UTILITY CLEARANCE

NUMBER OF BLOWS FOR 4 INCHES OF PENETRATION

(UNLESS OTHERWISE NOTED).

SPT VALUE FOR 12 INCHES OF PENETRATION

NUMBERS TO THE LEFT OF BORINGS INDICATE

FOR CONFIRMATION OF VISUAL REVIEW.

AND LABORATORY TESTING ON SELECTED SAMPLES

GROUP SYMBOL AS DETERMINED BY VISUAL REVIEW

UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D 2487)

NGVD 29

NAVD 88

NP

PI

LL

NMC

-200

HA

50/4

N

SP

BROWN CLAY (CL/CH)

GRAY TO BROWN SILT (ML/MH)

THE COUNTY.

LEVELS UP TO +15 FEET, NGVD 29 (+14.5 FEET, NAVD 88) AT NO ADDITIONAL COST TO

THE CONTRACTOR SHOULD BE PREPARED TO ADDRESS AND HANDLE POTENTIOMETRIC

ARTESIAN CONDITIONS WERE NOT ENCOUNTERED DURING THE FIELD EXPLORATION.

IN THE PROJECT VICINITY RANGES UP TO +15 FEET, NGVD 29 (+14.5 FEET, NAVD 88).

ELEVATION" MAPS PROVIDED BY THE USGS, THE POTENTIOMETRIC SURFACE ELEVATION

BASED ON A REVIEW OF THE "UPPER FLORIDAN AQUIFER POTENTIOMETRIC SURFACE

THIS MATERIAL SHOULD BE ANTICIPATED.

OF SPECIALIZED EQUIPMENT. VARIATIONS IN THE DEPTH AND RELATIVE DENSITY OF

MAY REQUIRE NON-CONVENTIONAL CONSTRUCTION TECHNIQUES AND THE MOBILIZATION

ROCK-LIKE. EXCAVATION INTO AND THROUGH THIS MATERIAL WILL BE DIFFICULT AND

HARD SILT WAS ENCOUNTERED IN THE BORINGS. THIS MATERIAL IS CONSIDERED

INTRUSION DURING SHAFT CONSTRUCTION.

COLLAPSE/SLOUGHING OF THE SANDY AND SILTY SOILS AND/OR GROUNDWATER

IN THE FDOT SPECIFICATIONS MAY BE REQUIRED IN ORDER TO PREVENT THE

TEMPORARY CASING METHODS FOR SHAFT INSTALLATION BEYOND WHAT IS REQUIRED

CONSTRUCTION.

GROUNDWATER TABLE LEVELS ARE PRONE TO CAVE-IN DURING DRILLED SHAFT

THE LOOSE/SOFT SOILS ENCOUNTERED WITHIN THE BORINGS COUPLED WITH SHALLOW

LOCATIONS AND ELEVATIONS SHOULD BE CONSIDERED APPROXIMATE.

FIELD IN CONJUNCTION WITH PROJECT DESIGN FILES PROVIDED BY WSP. THE BORING

LOCATIONS WERE DETERMINED USING THE GPS COORDINATES RECORDED IN THE

ACCURACY OF ± 10 FEET. STATION, OFFSET, AND ELEVATION OF THE BORING

HAND-HELD, NON-SURVEY GRADE GPS EQUIPMENT WITH A MANUFACTURER'S REPORTED

THE BORINGS WERE LOCATED IN THE FIELD BY A REPRESENTATIVE OF TIERRA USING

N

HA

HA

HA

BOR # SG-1115+30L

STA. 1115+38

REF.

OFF. 97' LT.

ELEV. 23.2

DATE 2/25/2025

DRILLER C. VIRGEN

HAMMER AUTOMATIC

RIG D-25

GNAN

HA

HA

HA

BOR # SG-1117+30R

STA. 1117+28

REF.

OFF. 83' RT.

ELEV. 23.7

DATE 2/25/2025

DRILLER C. VIRGEN

HAMMER AUTOMATIC

RIG D-25

£ CR 672 £ CR 672

SAND WITH SILT (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

SAND WITH SILT (SP/SP-SM)

GRAY TO BROWN TO DARK BROWN SAND TO

ELEVATION -6.8 FT (NAVD 88)

BORING TERMINATED AT

ELEVATION -6.3 FT (NAVD 88)

BORING TERMINATED AT

-5

-10

E L E

V A

T I O

N

I N

F

E E

T

N

A V

D

) 25

-5

-10

E L E

V A

T I O

N

I N

F

E E

T

N

A V

D

LONGITUDE: W 82.37217

LATITUDE: N 27.79246

LONGITUDE: W 82.37160

LATITUDE: N 27.79194

-200=4

PI=59

LL=113

NMC=95

-200=89

GRAY TO BROWN SILT (ML/MH) GRAY TO BROWN SILT (ML/MH)

J:\6511\2021 Files\6511-21-076 Big Bend Widening\Microstation\Geotech\SPTBSG_West02.dgnbsawaska 11/20/2025 3:33:14 PM Default

P

E N

T B

L L

P

L T

D R

V

69647000

(2 OF 2)

BIG BEND RD (US 41 TO COVINGTON GDN DR)

T

F I C I A

L

R

E C

O

T

H I S

S

H E

E T

I S

T

H E

E

L E

C T

R O

N I C

F I

G I T

A L L

Y

S I G

N

D

S

E A

L

D E

R

R

U L E

G .0

F .A .C

BORING LOCATION PLAN

Feet

100200

Station

(feet)

Offset

(feet) Reference

1084+72 46' LT. CL CR 672 SN-229L SAND 105 43 29 See attached table

1084+72 71' RT. CL CR 672 SN-229R SAND 105 43 29 See attached table

Notes:

(1) Recommend analysis be based on saturated conditions, i.e. analyze with the groundwater at the surface.

(2) Effective unit weight based on saturated conditions.

Recommended Soil Parameters for Overhead Sign Foundations

Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida

CIP No.: 69647000

Tierra Project No.: 6511-21-076

TRUSS

Total Saturated

Unit Weight

(γ, lb/ft (1)

Effective Unit

Weight

(γ, lb/ft (2)

N-Value

Structure Location Structure

Type

Reference

Boring Soil Type

Friction Angle

(φ,°)

Pole

ID

Intersection

Station

(feet)

Offset

(feet) Reference

Big Bend Rd. &

Industrial Dr.

1087+78 53' LT. CL CR 672 MAST ARM SG-1087+75L SAND 105 43 29 See attached table

Big Bend Rd. &

Industrial Dr.

1089+48 67' RT. CL CR 672 MAST ARM SG-1089+50R SAND 105 43 29 See attached table

Big Bend Rd. &

Kings Lake Rd.

1115+33 68' LT. CL CR 672 MAST ARM SG-1115+30L SAND 105 43 29 See attached table

Big Bend Rd. &

Kings Lake Rd.

1117+32 78' RT. CL CR 672 MAST ARM SG-1117+30R SAND 105 43 29 See attached table

Notes:

(2) Effective unit weight based on saturated conditions.

(1) Recommend analysis be based on saturated conditions, i.e. analyze with the groundwater at the surface.

Structure Location

Recommended Soil Parameters for Signal Poles

Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida

CIP No.: 69647000

Tierra Project No.: 6511-21-076

Total Saturated

Unit Weight

(γ, lb/ft (1)

Effective Unit

Weight

(γ, lb/ft (2)

N-Value Structure

Type

Reference

Boring Soil Type

Friction Angle

(φ,°)

Reference Boring: SN-1084+70L

11.5

Approximate

Shaft Depth

(feet)

Approximate

Shaft Elevation

(feet, NAVD 88)

Automatic Hammer SPT

N-Value

Corrected Safety

Hammer

N-Value (1)

Average Weighted

N-Value for use in

MATHCAD Torsional

Calculation

1 11.4 FILL

(3) 8.0 8

2 10.4 HA

(2) 4.0 5

3 9.4 HA

(2) 4.0 4

4 8.4 HA

(2) 4.0 4

5 7.4 HA

(2) 4.0 4

6 6.4 HA

(2) 4.0 4

7 5.4 HA

(2) 4.0 4

8 4.4 2 2.5 3

9 3.4 2 2.5 3

10 2.4 8 9.9 4

11 1.4 8 9.9 5

12 0.4 8 9.9 6

13 -0.6 8 9.9 6

14 -1.6 8 9.9 7

15 -2.6 13 16.1 8

16 -3.6 13 16.1 9

17 -4.6 13 16.1 9

18 -5.6 13 16.1 10

19 -6.6 13 16.1 10

20 -7.6 4 5.0 10

21 -8.6 4 5.0 9

22 -9.6 4 5.0 9

23 -10.6 4 5.0 8

24 -11.6 4 5.0 8

25 -12.6 4 5.0 8

26 -13.6 4 5.0 7

27 -14.6 4 5.0 7

28 -15.6 4 5.0 6

29 -16.6 4 5.0 6

30 -17.6 50/6 50.0 8

31 -18.6 50/6 50.0 9

32 -19.6 50/6 50.0 10

33 -20.6 50/6 50.0 11

34 -21.6 50/6 50.0 12

35 -22.6 62 50.0 13

36 -23.6 62 50.0 13

37 -24.6 62 50.0 14

38 -25.6 62 50.0 14

39 -26.6 62 50.0 15

40 -27.6 37 45.9 14

41 -28.6 37 45.9 14

42 -29.6 37 45.9 14

43 -30.6 37 45.9 14

44 -31.6 37 45.9 14

45 -32.6 50/5 50.0 14

46 -33.6 50/5 50.0 14

Recommended Average N-Value for MathCAD

Overhead Sign Structures

Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida

CIP No.: 69647000

Tierra Project No.: 6511-21-076

Approximate Structure Ground Elevation

(feet, NAVD 88):

12.4

Approximate Boring Elevation

(feet, NAVD 88):

Overhead Sign Structure RT. Foundation

Structure

Station & Offset:

(CL CR 672)

1084+72, 44' LT.

(1) Automatic Hammer SPT N-Value is corrected by a factor of 1.24 to equivalent Safety Hammer N-Value in accordance with

FDOT Specifications.

(2)

HA: Hand augered. Corrected Safety Hammer N-Value treated as 4.

(3) FILL: Fill material. Corrected Safety Hammer N-Value treated as 8.

Reference Boring: SN-1084+70R

10.0

Approximate

Shaft Depth

(feet)

Approximate

Shaft Elevation

(feet, NAVD 88)

Automatic Hammer SPT

N-Value

Corrected Safety

Hammer

N-Value (1)

Average Weighted

N-Value for use in

MATHCAD Torsional

Calculation

1 10.2 FILL

(3) 8.0 8

2 9.2 FILL

(3) 8.0 8

3 8.2 HA

(2) 4.0 5

4 7.2 HA

(2) 4.0 5

5 6.2 HA

(2) 4.0 4

6 5.2 HA

(2) 4.0 4

7 4.2 HA

(2) 4.0 4

8 3.2 HA

(2) 4.0 4

9 2.2 7 8.7 5

10 1.2 7 8.7 5

11 0.2 13 16.1 7

12 -0.8 13 16.1 8

13 -1.8 13 16.1 9

14 -2.8 13 16.1 10

15 -3.8 13 16.1 10

16 -4.8 9 11.2 10

17 -5.8 9 11.2 10

18 -6.8 9 11.2 11

19 -7.8 9 11.2 11

20 -8.8 9 11.2 11

21 -9.8 4 5.0 10

22 -10.8 4 5.0 9

23 -11.8 4 5.0 9

24 -12.8 4 5.0 9

25 -13.8 4 5.0 8

26 -14.8 58 50.0 10

27 -15.8 58 50.0 12

28 -16.8 58 50.0 13

29 -17.8 58 50.0 14

30 -18.8 58 50.0 15

31 -19.8 10 12.4 15

32 -20.8 10 12.4 14

33 -21.8 10 12.4 13

34 -22.8 10 12.4 13

35 -23.8 10 12.4 12

36 -24.8 44 50.0 13

37 -25.8 44 50.0 14

38 -26.8 44 50.0 14

39 -27.8 44 50.0 14

40 -28.8 44 50.0 15

41 -29.8 22 27.3 15

42 -30.8 22 27.3 14

43 -31.8 22 27.3 14

44 -32.8 22 27.3 14

45 -33.8 22 27.3 14

46 -34.8 65 50.0 14

47 -35.8 65 50.0 14

Tierra Project No.: 6511-21-076

Recommended Average N-Value for MathCAD

Overhead Sign Structures

Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida

CIP No.: 69647000

Approximate Structure Ground Elevation

(feet, NAVD 88):

11.2

Structure

Station & Offset:

(CL CR 672)

1084+72, 71' RT.

Approximate Boring Elevation

(feet, NAVD 88):

Overhead Sign Structure LT. Foundation

(1) Automatic Hammer SPT N-Value is corrected by a factor of 1.24 to equivalent Safety Hammer N-Value in accordance with

FDOT Specifications.

(3) FILL: Fill material. Corrected Safety Hammer N-Value treated as 8.

Reference Boring: SG-1087+75L

12.0

Approximate Shaft Depth

(feet)

Automatic Hammer SPT N-

Value

Corrected Safety Hammer

N-Value (1)

Average Weighted N-Value for use in MATHCAD

Torsional Calculation

1 HA

(2) 4.0 4

2 HA

(2) 4.0 4

3 HA

(2) 4.0 4

4 HA

(2) 4.0 4

5 HA

(2) 4.0 4

6 HA

(2) 4.0 4

7 10 12.4 6

8 10 12.4 7

9 6 7.4 7

10 6 7.4 7

11 6 7.4 7

12 6 7.4 7

13 6 7.4 7

14 12 14.9 8

15 12 14.9 9

16 12 14.9 10

17 12 14.9 10

18 12 14.9 11

19 11 13.6 11

20 11 13.6 11

21 11 13.6 11

22 11 13.6 11

23 11 13.6 12

24 3 3.7 11

25 3 3.7 10

26 3 3.7 9

27 3 3.7 9

28 3 3.7 8

29 50/3 50.0 10

30 50/3 50.0 11

(1) Automatic Hammer SPT N-Value is corrected by a factor of 1.24 to equivalent Safety Hammer N-Value in accordance with FDOT Specifications.

Recommended Average N-Value for MathCAD

Mast Arm Signal Poles

Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida

CIP No.: 69647000

Tierra Project No.: 6511-21-076

Approximate Structure

Ground Elevation

(feet, NAVD 88):

N/A

Approximate Boring

Elevation

(feet, NAVD 88):

Mast Arm Signal Pole

Structure

Station & Offset:

(CL CR 672)

1087+78, 53' LT.

Reference Boring: SG-1089+50R

12.0

Approximate Shaft Depth

(feet)

Automatic Hammer SPT N-

Value

Corrected Safety Hammer

N-Value (1)

Average Weighted N-Value for use in MATHCAD

Torsional Calculation

1 HA

(2) 4.0 4

2 HA

(2) 4.0 4

3 HA

(2) 4.0 4

4 HA

(2) 4.0 4

5 9 11.2 6

6 9 11.2 7

7 6 7.4 7

8 6 7.4 7

9 5 6.2 7

10 5 6.2 7

11 5 6.2 7

12 5 6.2 6

13 5 6.2 6

14 4 5.0 6

15 4 5.0 6

16 4 5.0 6

17 4 5.0 6

18 4 5.0 5

19 5 6.2 5

20 5 6.2 5

21 5 6.2 5

22 5 6.2 5

23 5 6.2 4

24 19 23.6 5

25 19 23.6 6

26 19 23.6 6

27 19 23.6 7

28 19 23.6 7

29 19 23.6 7

30 19 23.6 7 (1)

Automatic Hammer SPT N-Value is corrected by a factor of 1.24 to equivalent Safety Hammer N-Value in accordance with FDOT Specifications.

Approximate Structure

Ground Elevation

(feet, NAVD 88):

N/A

Structure

Station & Offset:

(CL CR 672)

1089+48, 67' RT.Approximate Boring

Elevation

(feet, NAVD 88):

Mast Arm Signal Pole

Recommended Average N-Value for MathCAD

Mast Arm Signal Poles

Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida

CIP No.: 69647000

Reference Boring: SG-1115+30L

22.0

Approximate Shaft Depth

(feet)

Automatic Hammer SPT N-

Value

Corrected Safety Hammer

N-Value (1)

Average Weighted N-Value for use in MATHCAD

Torsional Calculation

1 HA

(2) 4.0 4

2 HA

(2) 4.0 4

3 HA

(2) 4.0 4

4 HA

(2) 4.0 4

5 HA

(2) 4.0 4

6 HA

(2) 4.0 4

7 4 5.0 4

8 4 5.0 4

9 5 6.2 4

10 5 6.2 5

11 5 6.2 5

12 5 6.2 5

13 5 6.2 5

14 8 9.9 6

15 8 9.9 6

16 8 9.9 7

17 8 9.9 7

18 8 9.9 7

19 5 6.2 7

20 5 6.2 7

21 5 6.2 7

22 5 6.2 7

23 5 6.2 7

24 22 27.3 7

25 22 27.3 8

26 22 27.3 8

27 22 27.3 9

28 22 27.3 9

29 5 6.2 9

30 5 6.2 8 (1)

Automatic Hammer SPT N-Value is corrected by a factor of 1.24 to equivalent Safety Hammer N-Value in

Ground Elevation

(feet, NAVD 88):

N/A

Structure

Station & Offset:

(CL CR 672)

1115+33, 68' LT.Approximate Boring

Elevation

(feet, NAVD 88):

Mast Arm Signal Pole

Recommended Average N-Value for MathCAD

Mast Arm Signal Poles

Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida

Reference Boring: SG-1117+30R

23.5

Approximate Shaft Depth

(feet)

Automatic Hammer SPT N-

Value

Corrected Safety Hammer

N-Value (1)

Average Weighted N-Value for use in MATHCAD

Torsional Calculation

1 HA

(2) 4.0 4

2 HA

(2) 4.0 4

3 HA

(2) 4.0 4

4 HA

(2) 4.0 4

5 HA

(2) 4.0 4

6 HA

(2) 4.0 4

7 2 2.5 3

8 2 2.5 3

9 3 3.7 3

10 3 3.7 3

11 3 3.7 3

12 3 3.7 3

13 3 3.7 3

14 11 13.6 4

15 11 13.6 6

16 11 13.6 6

17 11 13.6 7

18 11 13.6 8

19 9 11.2 8

20 9 11.2 8

21 9 11.2 9

22 9 11.2 9

23 9 11.2 9

24 29 36.0 9

25 29 36.0 10

26 29 36.0 10

27 29 36.0 10

28 29 36.0 11

29 5 6.2 10

30 5 6.2 10 (1)

Automatic Hammer SPT N-Value is corrected by a factor of 1.24 to equivalent Safety Hammer N-Value in

Ground Elevation

(feet, NAVD 88):

N/A

Structure

Station & Offset:

(CL CR 672)

1117+32, 78' RT.Approximate Boring

Elevation

(feet, NAVD 88):

Mast Arm Signal Pole

Recommended Average N-Value for MathCAD

Mast Arm Signal Poles

Big Bend Rd. (CR 672) from US Hwy. 41 to Covington Garden Dr.

Hillsborough County, Florida

File details come from the government source that posted it. Updated .