2-Florida Trench Safety Act, Certification and Disclosure Statement.pdf.pdf
PDF 17 KB Posted
- Attached to
- Big Bend Road from US 41 to Covington Garden Dr.
- Solicitation number
- IFB-26-00378
- Issued by
- Hillsborough County, Florida
About this file
This document is a Florida Trench Safety Act Certification and Disclosure Statement issued by Hillsborough County, Florida, mandatory for bidders on the Big Bend Road resurfacing and widening project. The statement requires bidders to certify compliance with the Florida Trench Safety Act and acknowledge that excavation and trench safety standards are based on Federal standards set forth in 29 CFR Part 1926.650, Subpart P, which may be supplemented by state or local requirements. Bidders must demonstrate that they have considered available geotechnical information and selected appropriate trench safety systems, accepting sole responsibility for their design and implementation. The certification form includes a detailed itemization table where bidders must disclose specific trench safety measures, quantities in linear feet, unit costs, and extended costs for each safety measure employed on the project, with the total reflecting the amount allocated in the contract requirement titled "Florida Trench Safety Act."
The disclosed trench safety costs represent only the minimum anticipated compliance expenses and do not limit the contractor's full obligation to meet all applicable standards. Hillsborough County explicitly reserves the right to require contractors to expend additional funds beyond the disclosed amount, at no additional cost to the county, to achieve full regulatory compliance. Notably, the county's acceptance of a bid and associated cost certification does not constitute an evaluation or approval of cost adequacy, nor does it relieve the contractor of its sole responsibility to comply with all trench safety requirements. The authorized representative of the bidding firm must sign and date the certification, acknowledging these conditions and committing the firm to compliance upon contract award and execution.
View the file
Other files
Show 40 more
Latest 50 of 89 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HILLSBOROUGH COUNTY, FLORIDA
FLORIDA TRENCH SAFETY ACT
CERTIFICATION AND DISCLOSURE STATEMENT (MANDATORY)
The undersigned acknowledges the requirements of the Florida Trench Safety Act and hereby certifies that the undersigned is an authorized representative of the bidder and in that capacity commits the bidder to the following in the performance of the work in the event that the subject contract is awarded to and executed by said bidder.
1. The bidder acknowledges the Florida Trench Safety Act and the requirements established herein.
2. The bidder further acknowledges that the aforementioned Act established the Federal excavation safety standards set forth at 29
CFR Part 1926.650, Subpart P as the interim State standard until such time as the State of Florida, through its Department of Labor and Employment Security, or any successor agency, adopts, updates or reviews said interim standard. This State of Florida standard may be supplemented by special shoring requirements established by the State of Florida or any of its political subdivisions.
3. The bidder, as Contractor, shall comply with all applicable excavation/trench safety standards.
4. The Contractor shall consider the geotechnical information available from the County, its own sources and all other relevant information in its design of the trench safety system it will employ on the subject project. The Contractor acknowledges that it is solely responsible for the selection of the data on which it relies in designing said safety system, as well as for the system itself.
5. The amount the bidder has set forth in the requirement titled “Florida Trench Safety Act” includes the following excavation/trench safety measures and the linear feet of trench excavated under each safety measure. These units, cost and the unit prices inferred shall be disclosed solely for the purpose of compliance with the procedural requirements of the aforementioned Act. No adjustment to the Contract Time or Price shall be made for any difference in the number of linear feet of trench excavation, except as may otherwise be provided in these Contract Documents.
Trench Safety Measure
(Description) Unit
(QTY)
Unit of
Measure
(LF, SY)
Unit Cost Extended Cost
A. _____________________ __________ __________ $___________ $___________
B. _____________________ __________ __________ $___________ $___________
C. _____________________ __________ __________ $___________ $___________
D. _____________________ __________ __________ $___________ $___________
TOTAL $___________
Total above must be identical to cost shown in the requirement titled “Florida Trench Safety Act”. (Use additional blank sheets to further itemize if more room is required.)
6. This amount disclosed as the cost of compliance with the applicable trench safety requirement does not constitute the extent of the
Contractor's obligation to comply with said standards. Contractor shall expend additional sums, at no additional cost to the County (except as may otherwise be provided), which are necessary to so comply.
7. Acceptance of the bid to which this certification and disclosure applies in no way represents that the County or its representatives has evaluated and thereby determined that the above costs are adequate to comply with the applicable trench safety requirements nor does it in any way relieve the bidder, as Contractor, of its sole responsibility to comply with the applicable trench safety requirements.
(Authorized Signature)
(Typed name of firm, corporation, business or individual)
(Date)
File details come from the government source that posted it. Updated .