WWYK143004_CU503.pdf

PDF 367 KB Posted

Attached to
Tinker AFB MAC BOA - WWYK240176 - Replace Industrial Waste Lift Stations 6N & 6S, B62501
Solicitation number
FA813726R0043
Issued by

About this file

This is a technical drawing document (CU503 Manhole Details) prepared by Burns & McDonnell for the U.S. Army Corps of Engineers Tulsa District, showing standard specifications and construction details for manhole and curb inlet installations at Tinker Air Force Base in Oklahoma City. The project is identified as the KC-46A Depot Maintenance Complex Support Infrastructure (Contract No. W912BV-16-C-0029, File No. WWYK143004).

The document provides comprehensive construction specifications for precast and cast-in-place concrete manholes, including detailed reinforcement schedules, pipe opening details, manhole adjustment specifications for both aircraft-rated and non-aircraft-rated installations, water/sewer line crossing details, and curb inlet configurations. Key technical requirements include: minimum 4000 PSI concrete strength at 28 days, reinforcing steel with 60 KSI yield strength, H-20 traffic rating for all manhole structures with aircraft rating required for airfield pavement locations, allowable soil bearing pressure of 2500 lbs/ft², 3-inch diameter weep holes with geotextile or hardware cloth protection, and lap splice requirements based on bar sizes. Manhole diameters are specified based on outlet pipe sizes (48 inches for 8-14 inch pipes through 96 inches for 60-66 inch pipes). The document establishes that contractors must submit structural drawings and design calculations sealed by a registered professional engineer in Oklahoma for all precast structures, with buoyancy calculations assuming water level at grade.

View the file

Other files

File Type Posted
240176_ATT02_STATEMENT OF WORK_Admendment 2.pdf PDF
Solicitation - FA813726R0043.pdf PDF
240176_ATT09_SOW.pdf PDF
240176_STATEMENT OF WORK-Amendment 1.pdf PDF
240176_ATT 11_Submittal Register.xlsx XLSX spreadsheet
240176_ATT 10_Design Narrative.pdf PDF
Industrial Waste Lines 1969.pdf PDF
WWYK143004_CU507.pdf PDF
WWYK143004_CU500.pdf PDF
WWYK143004_CU504.pdf PDF
Pages from 910139.pdf PDF
20010298.pdf PDF
710237.pdf PDF
430515.pdf PDF
2025 TAFB Electrical Standards - Signed.pdf PDF
01 78 00.pdf PDF
UMRL.pdf PDF
ERDCITL_TR12-6_r6.pdf PDF
ufc_3_260_01_2019_c1.pdf PDF
EM_385-1-1.pdf PDF
tinkerafb_INRMP_App G.pdf PDF
dafi21-101.pdf PDF
dafi13-213.pdf PDF
afman40-201.pdf PDF
dodio-2000.16v1_afi10-245-o.pdf PDF
tinkerafbi21-100.pdf PDF
007200_Attch13_AF487.pdf PDF
007200_Attch7a_AF3952.pdf PDF
SOW Att 02a_Controlled Area Training.pptx PPTX presentation
240176_ATT 11_Submittal Register.pdf PDF
240176_Final_ Plan Set.pdf PDF
WWYK143004_CU502.pdf PDF
WWYK143004_CU513.pdf PDF
WWYK143004_CU501.pdf PDF
WWYK143004_CU505.pdf PDF
20090026A.pdf PDF
B02119.txt TXT text file
690255.pdf PDF
480211.pdf PDF
Combined As-Built Record Dwgs.pdf PDF
FIRE SUPPRESSION GEODESIC SHOP DRAWINGS AS-BUILTS.pdf PDF
2025 TAFB Mechanical Standard_Signed.pdf PDF
01 33 00.pdf PDF
01 33 16.00 10.pdf PDF
01 32 16.00 20.pdf PDF
tinkerafb_INRMP.pdf PDF
afman32-7003.pdf PDF
afman48-148.pdf PDF
dafi13-213_tinkerafbsup.pdf PDF
017800_Attch1_DD1354.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

36" MIN.

CAST-IN-PLACE

CONCRETE

BENCH

RIM OR TOP

ELEVATION

VA

R

IE

S

- S

EE

P R

O

FI

LE

S

SE

E

ST

R

U C

TU

R

ES

T

AB

LE

O N

C U

48" DIA. (MIN)

SEE NOTES 5 AND 15

PRECAST OR

CAST-IN-PLACE

CONCRETE BASE

#4 @ 12" EACH

WAY TOP FACE - 2"

CLEAR

GROUT

PRECAST

CONCRETE

RISER

ECCENTRIC

CONE

GRADE RINGS

AS NEEDED

COVER AND FRAME

SECURELY SEATED IN 1:2

GROUT MIXTURE

MANHOLE COVER

AND FRAME

MANHOLE

COVER AND

FRAME

PLAN VIEW

SECTION A-A

VA

R

IE

S

M

IN

)4" MIN

ENCASEMENT

(TYP 3 SIDES)

NOTES:

1. INSTALL DROP MANHOLE ON ALL SEWER OR

INDUSTRIAL WASTE STRUCTURES WHERE THE INLET

PIPE ELEVATION/INVERT IS MORE THAN 24" ABOVE

THE OUTLET PIPE ELEVATION/INVERT.

2. MATCH CROWN OF DROP PIPE INLET WITH CROWN OF

OUTLET PIPE.

3. DIAMETER OF DROP PIPE SHALL BE SAME AS INLET

PIPE.

DO NOT ENCASE

BEYOND BELL

CONCRETE BASE

SHALL EXTEND UNDER

DROP CONNECTION

ON NEW MANHOLES.

WATER LINE

WATER LINE

SEWER LINE

20.00' 20.00'

" M

IN

PROPOSED OR

EXISTING GRADE

NOTES:

1. ALL SANITARY SEWER LINES THAT CROSS LESS THAN 24 INCHES ABOVE OR BELOW WATER

MAINS OR SERVICE LINES SHALL BE SEAMLESS HDPE PIPE FOR 10 FEET EACH SIDE OF THE

CENTERLINE OF THE CROSSING. SEWER PIPE SHALL BE TESTED IN ACCORDANCE WITH THE

SPECIFICATIONS FOR PRESSURE PIPE. CONTRACTOR MAY LOWER WATER LINES TO CLEAR

MORE THAN 24 INCHES BELOW THE SEWER LINE OR RAISE THEM TO CLEAR MORE THAN 24

INCHES ABOVE THE SEWER LINE BUT MUST MAINTAIN THE MINIMUM BURY DEPTH/COVER OF 42

INCHES ON ALL WATER MAINS AND SERVICE LINES AND 42 INCHES FOR ALL FIREWATER MAINS.

2. LENGTH OF EXTENSION OF PIPE AND RESTRAINED JOINTS SHALL BE IN ACCORDANCE WITH THE

SPECIFICATIONS AND DRAWINGS.

3. CATHODIC PROTECTION SHALL BE AS REQUIRED IN ACCORDANCE WITH THE SPECIFICATIONS

AND DRAWINGS.

4. A BORED CROSSING MAY BE REQUIRED BY THE CONTRACTOR.

SEE NOTE 1 FOR WATER LINES

ABOVE OR BELOW SEWER LINES.

45° ELBOW

(TYP)

REINFORCING

BSA BSB WV WHA* WHB* TSA TSB

RANGE OF

0' to 3'-11" #4@12" T

CURB INLET DATA SCHEDULE

LEGEND:

4' x 3'

NOTES:

1. VARIABLE DIMENSIONS (A,B,D & T) FOR STRUCTURES ARE SHOWN ON THE

SCHEDULE.

2. THE SAME WALL THICKNESS AND SIZE AND SPACING OF REINFORCING SHALL

BE USED FOR THE FULL HEIGHT OF EACH INDIVIDUAL STRUCTURE BASED ON

THE MAXIMUM REQUIRED FOR THE DEPTH "D" ACCORDING TO THE SCHEDULE.

"D" IS MEASURED FROM THE TOP OF THE CURB BOX TO THE INVERT OF THE

OUTFALL PIPE AT THE CENTERLINE OF THE STRUCTURE.

3. FRAME, GRATE AND CURB BOX SHALL BE NEENAH R-3067-L OR APPROVED

EQUAL.

4. THE GROUT SHALL BE LIMITED TO THAT REQUIRED TO PREVENT STANDING

WATER. WHERE PIPES HAVE NEARLY THE SAME INVERT ELEVATION, GROUT

SHALL TAPER FROM THE SIDES TOWARDS THE FLOWLINE BETWEEN PIPES

WITH NO GROUT PLACED ALONG AND 3" EACH SIDE OF THE FLOWLINE.

5. THE REINFORCEMENT CLEARANCE OF 1-1/2" SHOWN IS APPLICABLE TO #5

BARS AND SMALLER. THE CLEARANCE FOR #6 BARS AND LARGER IS 2".

6. REINFORCING STEEL FY = 60 KSI.

7. THE MINIMUM CLEAR COVER OF CONCRETE OVER REINFORCING STEEL SHALL

BE 3" FOR CONCRETE PLACED DIRECTLY AGAINST THE SOIL.

BSA BOTTOM STEEL IN "A" DIRECTION

BSB BOTTOM STEEL IN "B" DIRECTION

WV WALL STEEL VERTICAL

WHA WALL STEEL HORIZONTAL IN "A" WALL

WHB WALL STEEL HORIZONTAL IN "B" WALL

T WALL THICKNESS

G U

TT

ER

SL

O

PE

SLOPE

4' x 3' 3' x 2.5' 3' x 2.5' 12' to 14'

4' to 7'-11" 8' to 11'-11"

6" 6" 6" 7"

#4@12" #4@10" #4@10"

#4@12" #4@12" #4@10" #4@10"

#4@12" #4@12" #4@12" #4@12"

#4@12" #4@9" #4@8" #5@9"

#4@12" #4@9" #4@8" #5@9"

#4@6" #4@6" #4@6" #4@6"

#4@6" #4@6" #4@6" #4@6"

MAX SIZE

"A" "B" DIMEN. "D"

CONCRETE

CURB AND

GUTTER

CAST IRON

FRAME, GRATE

AND CURB BOX

CONCRETE

CURB AND

GUTTER

9"

1' -3

4"

TYP

8" TY

P

"T""A""T"

FRAME AND GRATE (NEENAH

R-3246-AL OR APPROVED EQUAL)

CURB BOX

GUTTER

TOP OF CURB

WV

WV

WHB WHB

8 - #5 BARS (4 EACH

FACE) @ ALL PIPES

IN WALLS

#4 DOWELS AT

BARS WV ALL

WALLS (TYP.) BSA BSB

GROUT

2" C

LR

TY

P

"D

"T""B""T"

BSBBSA

GROUT

WHA

WV

FLARE

ENTRANCE TO

OUTFALL PIPE

WHA

WV

PAVEMENT

FRAME AND GRATE

CURB BOX SET TO 6" HEIGHT

1-1/2"

CLR

1- 1/

2" C

LR

1-1/2"

CLR

WHA

WV

1'-0" TYP

WV

WHB

WALL "B"

W

AL

L "A

1-1/2"

CLR

1-1/2"

CLR

WV

WHB

2' MAX

WALL "A"

W

AL

L "B

1 - #4

WHAPIPE WALL

1 - #4

1- 1/

2" C

LR

PLAN SECTION B SECTION C

SECTION 3 SECTION 4

TYP

2"

TYP

PIPE OR

MANHOLE

OPENING (D)

ADD 2 - #5

@ 3" EA

FACE

NOTE:

1. ALL BAR MINIMUM LENGTHS TO BE (D + 20")

WITH BARS CENTERED ON OPENINGS.

REMOVE EXISTING CONCRETE

OR BRICK AS REQUIRED AND

RESET FRAME

PLACE PRECAST CONCRETE

RINGS OR CONCRETE BRICK

(RADIALLY) AND MORTAR AS

REQUIRED AND RESET FRAME

TO MEET FINISHED GRADE

FINISH GRADE

FINISH GRADE

EXISTING GRADE

REMOVE AND REINSTALL

EXISTING CASTING TO MATCH

FINISHED GRADERAISE LOWER

MORTAR BEDDING

EXISTING STRUCTURAL WALL

H

W

SE

E

N O

TE

SE

E

N O

TE

RAISE LOWER

SE

E

N O

TE

CLEAN, ROUGHEN SURFACE

AND APPLY CEMENT BOND

COAT TO ALL EXISTING

CONCRETE SURFACES TO

RECEIVE CONCRETE TYP

Ø5/8" DOWEL

8" LONG @

12"O.C. BARS

Ø5/8" @ 12" O.C. BARS

2" X 3" KEY

CONCRETE

3000 PSI CONCRETE BRICK

FINISH GRADE

EXISTING

STRUCTURE

WALL

MORTAR

BEDDING

FINISH

GRADE

REMOVE AND REINSTALL

EXISTING TOP SLAB AND

CASTING TO MATCH

FINISHED GRADE

EXISTING GRADE

NOTES:

1. BUILD UP EXISTING WALLS WITH CONCRETE AS REQUIRED AND

RESET FRAME ON TWO COURSES OF CONCRETE BRICK AND

MORTAR (LAID RADIALLY).

2. REMOVE EXISTING WALL AS REQUIRED. CLEAN CONCRETE

SURFACE AND SET TOP SLAB ON MORTAR BEDDING.

3. H = DEPTH TO INTERIOR BOTTOM OF MANHOLE.

LAP SPLICE (IN)

3/4" 7/8" 1"

5/8" 1/2"

BAR SIZE (IN)

SCALE: NTS

CURB INLET DETAILSE1

SCALE: NTS

WATER/SEWER LINE CROSSING DETAILB1

SCALE: NTS

MANHOLE ADJUSTMENT DETAIL

6" OR MORE (NON-AIRCRAFT RATED)

B2

SCALE: NTS

MANHOLE ADJUSTMENT DETAIL

6" OR LESS (NON-AIRCRAFT RATED)

A3

SCALE: NTS

OUTSIDE DROP MANHOLEA1

SCALE: NTS

PRECAST CONCRETE MANHOLEA4

A

CU503

PRECAST MANHOLE NOTES:

1. MANHOLE STRUCTURE, MANHOLE COVER AND FRAME ARE TO BE H-20 TRAFFIC RATED. ALL MANHOLE

STRUCTURES AND MANHOLE COVERS AND FRAMES LOCATED IN AIRFIELD PAVEMENT ARE TO BE AIRCRAFT

RATED. SEE UTILITY STRUCTURES TABLE ON CU600.

2. THICKNESS AND REINFORCING FOR PRECAST CONCRETE MANHOLE WALLS AND REINFORCING FOR PRECAST CONCRETE FLAT TOPS ARE NOT SHOWN BUT SHALL CONFORM TO THE LOADING REQUIREMENTS INDICATED IN

NOTE 1.

3. MANHOLE BASE SLABS MAY BE PRECAST OR CAST-IN-PLACE CONCRETE. THICKNESS AND REINFORCING OF CAST-IN-PLACE BASE SHALL BE AS INDICATED. THICKNESS AND REINFORCING OF PRECAST BASES SHALL BE AS

REQUIRED BY MANUFACTURER. CONTRACTOR SHALL SUBMIT STRUCTURAL DRAWINGS AND DESIGN

CALCULATIONS, SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF OKLAHOMA, FOR APPROVAL ON ALL PRECAST STRUCTURES. BUOYANCY CALCULATIONS SHALL ASSUME WATER LEVEL IS AT

GRADE.

4. ALL PIPE ENTRIES INTO THE BASE OF MANHOLES SHALL BE CONNECTED BY OPEN CHANNELS FORMED USING CAST-IN-PLACE CONCRETE BENCHES. CHANNELS SHALL BE ADJUSTED FOR PIPE SIZE, SHAPE, SLOPE, AND DIRECTION OF FLOW. THE INVERT CHANNELS SHALL BE SMOOTH AND SEMICIRULAR IN SHAPE CONFORMING TO THE INSIDE OF THE ADJACENT PIPE SECTION. CHANGES IN DIRECTION OF FLOW SHALL BE MADE WITH A SMOOTH CURVE OF AS LARGE A RADIUS AS THE SIZE OF THE MANHOLE WILL PERMIT. CHANGES IN SIZE AND GRADE OF

THE CHANNELS SHALL BE MADE GRADUALLY AND EVENLY.

5. DIAMETER OF MANHOLE SHALL DEPEND ON NUMBER AND SIZE OF PIPES CONNECTING TO THE STRUCTURE. FOR LOCATION AND ORIENTATION, SEE UTILITY PLANS SHEETS. FOR DIAMETER OF MANHOLE, SEE STRUCTURES

TABLES ON CU600, CU601 AND NOTE 15.

6. MINIMUM CONCRETE STRENGTH = 4000 PSI AT 28 DAYS UNLESS NOTED OTHERWISE. MINIMUM REINFORCING STEEL YIELD STRENGTH = 4x106 PSI.

7. USE FULL CONTACT LAP SPLICES OF REINFORCING STEEL, SEE TABLE BELOW.

8. SEE PROJECT SPECIFICATIONS SECTION 31 00 00 FOR EXCAVATION, BACKFILL AND COMPACTION REQUIREMENTS.

9. ALLOWABLE SOIL BEARING PRESSURE UNDER MANHOLES AND INLETS EQUAL TO 2500 LBS\FT².

10. LOCATE AND INSTALL 3" DIAMETER WEEP HOLES TO DRAIN SUBBASE MATERIAL PRIOR TO PAVEMENT INSTALLATION. WEEP HOLE WITH 12" X 12" PLASTIC GEOTEXTILE CLOTH WITH 1/4" MESH OR GALVANIZED STEEL WIRE DIAMETER 0.03" NUMBER 4 MESH HARDWARE CLOTH ANCHORED FIRMLY TO OUTSIDE OF STRUCTURE.

11. IF A MANHOLE IS LOCATED IN PAVEMENT AREAS. RIM ELEVATION SHALL BE FLUSH WITH FINAL GRADE. IF A MANHOLE IS LOCATED OUTSIDE OF PAVEMENT AREAS, RIM ELEVATION SHALL BE 6" ABOVE ADJACENT FINISH

GRADE AND SITE SOILS MOUNDED UP TO THE RIM OVER A DISTANCE OF 5 FT.

12. COVERS AND CASTINGS OF MANHOLES AND STRUCTURES SHALL BE STAMPED PER THE APPROPRIATE UTILITY TYPE OR PER THE LOCAL STANDARDS AND SHALL BE STAMPED PER THE ORIGIN OF MANUFACTURE. SEE DETAIL

D4 AND D5 ON CU504 FOR STANDARD FRAME AND COVER REQUIREMENT.

13. ALL JOINTS SHALL BE SEALED WITH JOINT COMPOUND OR GROUTED WITH MORTAR.

14. ANY LIFT LOOPS FOR UTILITY STRUCTURES SHALL BE GROUTED FLUSH AFTER INSTALLATION.

15. MANHOLE DIAMETERS:

USE 48" MANHOLE FOR 8"-14" OUTLET PIPE.

USE 60" MANHOLE FOR 15"-30" OUTLET PIPE.

USE 72" MANHOLE FOR 36"-42" OUTLET PIPE.

USE 84" MANHOLE FOR 48"-54" OUTLET PIPE.

USE 96" MANHOLE FOR 60"-66" OUTLET PIPE.

SCALE: NTS

REINFORCING @ PIPE OPENING

OR MANHOLE LID OPENINGC5

B B

C C

GRAVITY BLOCK - SEE

DETAIL D5 ON CU501

THRUST BLOCK - SEE

DETAIL A3 ON CU500

A

REMOVE EXISTING

CONCRETE BY SAW

CUTTING

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

TU

LS

A D

IS

TR

IC

T

TU

LS

A, O

KL

AH

O M

A

BU

R

N S

M

C D

O N

N

EL

L

W

AR

D

P

AR

KW

AY

KA

N

SA

S

C

IT

Y, M

O

US Army Corps of Engineers Tulsa District

M

AR

K D

ES

C

R

IP

TI

O

N

SHEET

IDENTIFICATION

D

AT

E

AP

PR

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N

AM

E:

D W

N B

Y:

C

KD

B

Y:

D

ES

IG

N

ED

B

Y:

D

AT

E:

FI

LE

N U

M

BE

R

SI

ZE

SB

M

T

BY

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

C O

N

TR

AC

T

N O

5 6

D

C

A

B

1 2 3 4

E

"X

C O

PY

R

IG

H

T

B

U R

N S

M cD O

N N

EL

L

EN

G

IN

EE

R

IN

G C

O M

PA

N

Y, IN

C

KC

-4

6A D

EP

O

T M

AI

N

T C

O M

PL

EX

S U

PP

O

R T

IN

FR

A.

O

KL

AH

O

M A

C

IT

Y, O

KL

AH

O M

A

TI

N

KE

R A

IR

F

O R

C E

BA

SE

W W

YK

CU

0-

CU

6.D

W G

PD

C

:W W

YK

FY

:1

SHEET

IF SHEET IS LESS THAN 42 X 30

REDUCED PRINT - USE GRAPHIC SCALE

D

C

A

B

E

5 61 2 3 4

AS-BUILT (CWG)

M

AY

W

2B V-

-C

-0

CU503

M

AN

H O

LE

D

ET

AI

LS

K.

W

AR

TA

D . M

U

ET

IN

G

R . B

AR

U

TH

K.

W

AR

TA

1:

7/ 1/

Sheets and Views
CU503