This is a technical drawing document (CU503 Manhole Details) prepared by Burns & McDonnell for the U.S. Army Corps of Engineers Tulsa District, showing standard specifications and construction details for manhole and curb inlet installations at Tinker Air Force Base in Oklahoma City. The project is identified as the KC-46A Depot Maintenance Complex Support Infrastructure (Contract No. W912BV-16-C-0029, File No. WWYK143004).
The document provides comprehensive construction specifications for precast and cast-in-place concrete manholes, including detailed reinforcement schedules, pipe opening details, manhole adjustment specifications for both aircraft-rated and non-aircraft-rated installations, water/sewer line crossing details, and curb inlet configurations. Key technical requirements include: minimum 4000 PSI concrete strength at 28 days, reinforcing steel with 60 KSI yield strength, H-20 traffic rating for all manhole structures with aircraft rating required for airfield pavement locations, allowable soil bearing pressure of 2500 lbs/ft², 3-inch diameter weep holes with geotextile or hardware cloth protection, and lap splice requirements based on bar sizes. Manhole diameters are specified based on outlet pipe sizes (48 inches for 8-14 inch pipes through 96 inches for 60-66 inch pipes). The document establishes that contractors must submit structural drawings and design calculations sealed by a registered professional engineer in Oklahoma for all precast structures, with buoyancy calculations assuming water level at grade.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
36" MIN.
CAST-IN-PLACE
CONCRETE
BENCH
RIM OR TOP
ELEVATION
VA
R
IE
S
- S
EE
P R
O
FI
LE
S
SE
E
ST
R
U C
TU
R
ES
T
AB
LE
O N
C U
48" DIA. (MIN)
SEE NOTES 5 AND 15
PRECAST OR
CAST-IN-PLACE
CONCRETE BASE
#4 @ 12" EACH
WAY TOP FACE - 2"
CLEAR
GROUT
PRECAST
CONCRETE
RISER
ECCENTRIC
CONE
GRADE RINGS
AS NEEDED
COVER AND FRAME
SECURELY SEATED IN 1:2
GROUT MIXTURE
MANHOLE COVER
AND FRAME
MANHOLE
COVER AND
FRAME
PLAN VIEW
SECTION A-A
VA
R
IE
S
M
IN
)4" MIN
ENCASEMENT
(TYP 3 SIDES)
NOTES:
1. INSTALL DROP MANHOLE ON ALL SEWER OR
INDUSTRIAL WASTE STRUCTURES WHERE THE INLET
PIPE ELEVATION/INVERT IS MORE THAN 24" ABOVE
THE OUTLET PIPE ELEVATION/INVERT.
2. MATCH CROWN OF DROP PIPE INLET WITH CROWN OF
OUTLET PIPE.
3. DIAMETER OF DROP PIPE SHALL BE SAME AS INLET
PIPE.
DO NOT ENCASE
BEYOND BELL
CONCRETE BASE
SHALL EXTEND UNDER
DROP CONNECTION
ON NEW MANHOLES.
WATER LINE
WATER LINE
SEWER LINE
20.00' 20.00'
" M
IN
PROPOSED OR
EXISTING GRADE
NOTES:
1. ALL SANITARY SEWER LINES THAT CROSS LESS THAN 24 INCHES ABOVE OR BELOW WATER
MAINS OR SERVICE LINES SHALL BE SEAMLESS HDPE PIPE FOR 10 FEET EACH SIDE OF THE
CENTERLINE OF THE CROSSING. SEWER PIPE SHALL BE TESTED IN ACCORDANCE WITH THE
SPECIFICATIONS FOR PRESSURE PIPE. CONTRACTOR MAY LOWER WATER LINES TO CLEAR
MORE THAN 24 INCHES BELOW THE SEWER LINE OR RAISE THEM TO CLEAR MORE THAN 24
INCHES ABOVE THE SEWER LINE BUT MUST MAINTAIN THE MINIMUM BURY DEPTH/COVER OF 42
INCHES ON ALL WATER MAINS AND SERVICE LINES AND 42 INCHES FOR ALL FIREWATER MAINS.
2. LENGTH OF EXTENSION OF PIPE AND RESTRAINED JOINTS SHALL BE IN ACCORDANCE WITH THE
SPECIFICATIONS AND DRAWINGS.
3. CATHODIC PROTECTION SHALL BE AS REQUIRED IN ACCORDANCE WITH THE SPECIFICATIONS
AND DRAWINGS.
4. A BORED CROSSING MAY BE REQUIRED BY THE CONTRACTOR.
SEE NOTE 1 FOR WATER LINES
ABOVE OR BELOW SEWER LINES.
45° ELBOW
(TYP)
REINFORCING
BSA BSB WV WHA* WHB* TSA TSB
RANGE OF
0' to 3'-11" #4@12" T
CURB INLET DATA SCHEDULE
LEGEND:
4' x 3'
NOTES:
1. VARIABLE DIMENSIONS (A,B,D & T) FOR STRUCTURES ARE SHOWN ON THE
SCHEDULE.
2. THE SAME WALL THICKNESS AND SIZE AND SPACING OF REINFORCING SHALL
BE USED FOR THE FULL HEIGHT OF EACH INDIVIDUAL STRUCTURE BASED ON
THE MAXIMUM REQUIRED FOR THE DEPTH "D" ACCORDING TO THE SCHEDULE.
"D" IS MEASURED FROM THE TOP OF THE CURB BOX TO THE INVERT OF THE
OUTFALL PIPE AT THE CENTERLINE OF THE STRUCTURE.
3. FRAME, GRATE AND CURB BOX SHALL BE NEENAH R-3067-L OR APPROVED
EQUAL.
4. THE GROUT SHALL BE LIMITED TO THAT REQUIRED TO PREVENT STANDING
WATER. WHERE PIPES HAVE NEARLY THE SAME INVERT ELEVATION, GROUT
SHALL TAPER FROM THE SIDES TOWARDS THE FLOWLINE BETWEEN PIPES
WITH NO GROUT PLACED ALONG AND 3" EACH SIDE OF THE FLOWLINE.
5. THE REINFORCEMENT CLEARANCE OF 1-1/2" SHOWN IS APPLICABLE TO #5
BARS AND SMALLER. THE CLEARANCE FOR #6 BARS AND LARGER IS 2".
6. REINFORCING STEEL FY = 60 KSI.
7. THE MINIMUM CLEAR COVER OF CONCRETE OVER REINFORCING STEEL SHALL
BE 3" FOR CONCRETE PLACED DIRECTLY AGAINST THE SOIL.
BSA BOTTOM STEEL IN "A" DIRECTION
BSB BOTTOM STEEL IN "B" DIRECTION
WV WALL STEEL VERTICAL
WHA WALL STEEL HORIZONTAL IN "A" WALL
WHB WALL STEEL HORIZONTAL IN "B" WALL
T WALL THICKNESS
G U
TT
ER
SL
O
PE
SLOPE
4' x 3' 3' x 2.5' 3' x 2.5' 12' to 14'
4' to 7'-11" 8' to 11'-11"
6" 6" 6" 7"
#4@12" #4@10" #4@10"
#4@12" #4@12" #4@10" #4@10"
#4@12" #4@12" #4@12" #4@12"
#4@12" #4@9" #4@8" #5@9"
#4@12" #4@9" #4@8" #5@9"
#4@6" #4@6" #4@6" #4@6"
#4@6" #4@6" #4@6" #4@6"
MAX SIZE
"A" "B" DIMEN. "D"
CONCRETE
CURB AND
GUTTER
CAST IRON
FRAME, GRATE
AND CURB BOX
CONCRETE
CURB AND
GUTTER
9"
1' -3
4"
TYP
8" TY
P
"T""A""T"
FRAME AND GRATE (NEENAH
R-3246-AL OR APPROVED EQUAL)
CURB BOX
GUTTER
TOP OF CURB
WV
WV
WHB WHB
8 - #5 BARS (4 EACH
FACE) @ ALL PIPES
IN WALLS
#4 DOWELS AT
BARS WV ALL
WALLS (TYP.) BSA BSB
GROUT
2" C
LR
TY
P
"D
"T""B""T"
BSBBSA
GROUT
WHA
WV
FLARE
ENTRANCE TO
OUTFALL PIPE
WHA
WV
PAVEMENT
FRAME AND GRATE
CURB BOX SET TO 6" HEIGHT
1-1/2"
CLR
1- 1/
2" C
LR
1-1/2"
CLR
WHA
WV
1'-0" TYP
WV
WHB
WALL "B"
W
AL
L "A
1-1/2"
CLR
1-1/2"
CLR
WV
WHB
2' MAX
WALL "A"
W
AL
L "B
1 - #4
WHAPIPE WALL
1 - #4
1- 1/
2" C
LR
PLAN SECTION B SECTION C
SECTION 3 SECTION 4
TYP
2"
TYP
PIPE OR
MANHOLE
OPENING (D)
ADD 2 - #5
@ 3" EA
FACE
NOTE:
1. ALL BAR MINIMUM LENGTHS TO BE (D + 20")
WITH BARS CENTERED ON OPENINGS.
REMOVE EXISTING CONCRETE
OR BRICK AS REQUIRED AND
RESET FRAME
PLACE PRECAST CONCRETE
RINGS OR CONCRETE BRICK
(RADIALLY) AND MORTAR AS
REQUIRED AND RESET FRAME
TO MEET FINISHED GRADE
FINISH GRADE
FINISH GRADE
EXISTING GRADE
REMOVE AND REINSTALL
EXISTING CASTING TO MATCH
FINISHED GRADERAISE LOWER
MORTAR BEDDING
EXISTING STRUCTURAL WALL
H
W
SE
E
N O
TE
SE
E
N O
TE
RAISE LOWER
SE
E
N O
TE
CLEAN, ROUGHEN SURFACE
AND APPLY CEMENT BOND
COAT TO ALL EXISTING
CONCRETE SURFACES TO
RECEIVE CONCRETE TYP
Ø5/8" DOWEL
8" LONG @
12"O.C. BARS
Ø5/8" @ 12" O.C. BARS
2" X 3" KEY
CONCRETE
3000 PSI CONCRETE BRICK
FINISH GRADE
EXISTING
STRUCTURE
WALL
MORTAR
BEDDING
FINISH
GRADE
REMOVE AND REINSTALL
EXISTING TOP SLAB AND
CASTING TO MATCH
FINISHED GRADE
EXISTING GRADE
NOTES:
1. BUILD UP EXISTING WALLS WITH CONCRETE AS REQUIRED AND
RESET FRAME ON TWO COURSES OF CONCRETE BRICK AND
MORTAR (LAID RADIALLY).
2. REMOVE EXISTING WALL AS REQUIRED. CLEAN CONCRETE
SURFACE AND SET TOP SLAB ON MORTAR BEDDING.
3. H = DEPTH TO INTERIOR BOTTOM OF MANHOLE.
LAP SPLICE (IN)
3/4" 7/8" 1"
5/8" 1/2"
BAR SIZE (IN)
SCALE: NTS
CURB INLET DETAILSE1
SCALE: NTS
WATER/SEWER LINE CROSSING DETAILB1
SCALE: NTS
MANHOLE ADJUSTMENT DETAIL
6" OR MORE (NON-AIRCRAFT RATED)
B2
SCALE: NTS
MANHOLE ADJUSTMENT DETAIL
6" OR LESS (NON-AIRCRAFT RATED)
A3
SCALE: NTS
OUTSIDE DROP MANHOLEA1
SCALE: NTS
PRECAST CONCRETE MANHOLEA4
A
CU503
PRECAST MANHOLE NOTES:
1. MANHOLE STRUCTURE, MANHOLE COVER AND FRAME ARE TO BE H-20 TRAFFIC RATED. ALL MANHOLE
STRUCTURES AND MANHOLE COVERS AND FRAMES LOCATED IN AIRFIELD PAVEMENT ARE TO BE AIRCRAFT
RATED. SEE UTILITY STRUCTURES TABLE ON CU600.
2. THICKNESS AND REINFORCING FOR PRECAST CONCRETE MANHOLE WALLS AND REINFORCING FOR PRECAST CONCRETE FLAT TOPS ARE NOT SHOWN BUT SHALL CONFORM TO THE LOADING REQUIREMENTS INDICATED IN
NOTE 1.
3. MANHOLE BASE SLABS MAY BE PRECAST OR CAST-IN-PLACE CONCRETE. THICKNESS AND REINFORCING OF CAST-IN-PLACE BASE SHALL BE AS INDICATED. THICKNESS AND REINFORCING OF PRECAST BASES SHALL BE AS
REQUIRED BY MANUFACTURER. CONTRACTOR SHALL SUBMIT STRUCTURAL DRAWINGS AND DESIGN
CALCULATIONS, SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF OKLAHOMA, FOR APPROVAL ON ALL PRECAST STRUCTURES. BUOYANCY CALCULATIONS SHALL ASSUME WATER LEVEL IS AT
GRADE.
4. ALL PIPE ENTRIES INTO THE BASE OF MANHOLES SHALL BE CONNECTED BY OPEN CHANNELS FORMED USING CAST-IN-PLACE CONCRETE BENCHES. CHANNELS SHALL BE ADJUSTED FOR PIPE SIZE, SHAPE, SLOPE, AND DIRECTION OF FLOW. THE INVERT CHANNELS SHALL BE SMOOTH AND SEMICIRULAR IN SHAPE CONFORMING TO THE INSIDE OF THE ADJACENT PIPE SECTION. CHANGES IN DIRECTION OF FLOW SHALL BE MADE WITH A SMOOTH CURVE OF AS LARGE A RADIUS AS THE SIZE OF THE MANHOLE WILL PERMIT. CHANGES IN SIZE AND GRADE OF
THE CHANNELS SHALL BE MADE GRADUALLY AND EVENLY.
5. DIAMETER OF MANHOLE SHALL DEPEND ON NUMBER AND SIZE OF PIPES CONNECTING TO THE STRUCTURE. FOR LOCATION AND ORIENTATION, SEE UTILITY PLANS SHEETS. FOR DIAMETER OF MANHOLE, SEE STRUCTURES
TABLES ON CU600, CU601 AND NOTE 15.
6. MINIMUM CONCRETE STRENGTH = 4000 PSI AT 28 DAYS UNLESS NOTED OTHERWISE. MINIMUM REINFORCING STEEL YIELD STRENGTH = 4x106 PSI.
7. USE FULL CONTACT LAP SPLICES OF REINFORCING STEEL, SEE TABLE BELOW.
8. SEE PROJECT SPECIFICATIONS SECTION 31 00 00 FOR EXCAVATION, BACKFILL AND COMPACTION REQUIREMENTS.
9. ALLOWABLE SOIL BEARING PRESSURE UNDER MANHOLES AND INLETS EQUAL TO 2500 LBS\FT².
10. LOCATE AND INSTALL 3" DIAMETER WEEP HOLES TO DRAIN SUBBASE MATERIAL PRIOR TO PAVEMENT INSTALLATION. WEEP HOLE WITH 12" X 12" PLASTIC GEOTEXTILE CLOTH WITH 1/4" MESH OR GALVANIZED STEEL WIRE DIAMETER 0.03" NUMBER 4 MESH HARDWARE CLOTH ANCHORED FIRMLY TO OUTSIDE OF STRUCTURE.
11. IF A MANHOLE IS LOCATED IN PAVEMENT AREAS. RIM ELEVATION SHALL BE FLUSH WITH FINAL GRADE. IF A MANHOLE IS LOCATED OUTSIDE OF PAVEMENT AREAS, RIM ELEVATION SHALL BE 6" ABOVE ADJACENT FINISH
GRADE AND SITE SOILS MOUNDED UP TO THE RIM OVER A DISTANCE OF 5 FT.
12. COVERS AND CASTINGS OF MANHOLES AND STRUCTURES SHALL BE STAMPED PER THE APPROPRIATE UTILITY TYPE OR PER THE LOCAL STANDARDS AND SHALL BE STAMPED PER THE ORIGIN OF MANUFACTURE. SEE DETAIL
D4 AND D5 ON CU504 FOR STANDARD FRAME AND COVER REQUIREMENT.
13. ALL JOINTS SHALL BE SEALED WITH JOINT COMPOUND OR GROUTED WITH MORTAR.
14. ANY LIFT LOOPS FOR UTILITY STRUCTURES SHALL BE GROUTED FLUSH AFTER INSTALLATION.
15. MANHOLE DIAMETERS:
USE 48" MANHOLE FOR 8"-14" OUTLET PIPE.
USE 60" MANHOLE FOR 15"-30" OUTLET PIPE.
USE 72" MANHOLE FOR 36"-42" OUTLET PIPE.
USE 84" MANHOLE FOR 48"-54" OUTLET PIPE.
USE 96" MANHOLE FOR 60"-66" OUTLET PIPE.
SCALE: NTS
REINFORCING @ PIPE OPENING
OR MANHOLE LID OPENINGC5
B B
C C
GRAVITY BLOCK - SEE
DETAIL D5 ON CU501
THRUST BLOCK - SEE
DETAIL A3 ON CU500
A
REMOVE EXISTING
CONCRETE BY SAW
CUTTING
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
TU
LS
A D
IS
TR
IC
T
TU
LS
A, O
KL
AH
O M
A
BU
R
N S
M
C D
O N
N
EL
L
W
AR
D
P
AR
KW
AY
KA
N
SA
S
C
IT
Y, M
O
US Army Corps of Engineers Tulsa District
M
AR
K D
ES
C
R
IP
TI
O
N
SHEET
IDENTIFICATION
D
AT
E
AP
PR
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
FI
LE
N U
M
BE
R
SI
ZE
SB
M
T
BY
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
C O
N
TR
AC
T
N O
5 6
D
C
A
B
1 2 3 4
E
"X
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
KC
-4
6A D
EP
O
T M
AI
N
T C
O M
PL
EX
S U
PP
O
R T
IN
FR
A.
O
KL
AH
O
M A
C
IT
Y, O
KL
AH
O M
A
TI
N
KE
R A
IR
F
O R
C E
BA
SE
W W
YK
CU
0-
CU
6.D
W G
PD
C
:W W
YK
FY
:1
SHEET
IF SHEET IS LESS THAN 42 X 30
REDUCED PRINT - USE GRAPHIC SCALE
D
C
A
B
E
5 61 2 3 4
AS-BUILT (CWG)
M
AY
W
2B V-
-C
-0
CU503
M
AN
H O
LE
D
ET
AI
LS
K.
W
AR
TA
D . M
U
ET
IN
G
R . B
AR
U
TH
K.
W
AR
TA
1:
7/ 1/
| Sheets and Views |
| CU503 |
File details come from the government source that posted it. Updated .